Electrical Drawing Model

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

LEGEND

SYMBOL DESCRIPTION

TP MCCB For Official Use Only


DP MCCB

SP MCCB

A AMMETER
A B C D A B C D A B C D
V VOLTMETER
49'
48'-3" FUSE
48'-3" 13'-10" 14'-2" 13'-10" 4'-7"
13'-10" 14'-2" 13'-10" 13'-10" 14'-2" 13'-10"
2' 1'-2" 12'-8" 1'-2" 1'-4" 11'-8" 2' 3'-9" 5' 4'-3" 1'-3" 1'-4" 1'-5"
1'-2" 5'-10" 5' 1'-10" 1'-2" 1'-4" 9'-11" 9" 1' 9" 3' 2' 5' 4'-3" 4' 1'-3" 1'-2" 5'-10" 5' 3' 1'-4" 11'-8" 2' 1'-9" 2' 7'-6" 4'-3" 1'-3" 1'-4" 1'-5" AUTOMATIC MAIN FAILURE (AMF)
1'
1x40 MIRROR FTL
4 1'-2"
2'
4 4 1'-2"
2'
4 4 1'-2" 4
8"

2'-6" UP
7'-2"
2x40 SURFACE TYPE MIRROROPTICS FTL
3'-6"
4'-2" 5'-9" 5'-10" 5'-11" DOME LIGHT
3L11
3L12 2'
1' 2' 3 2L5
3
2L8 4" 9" WALL LIGHT
12' 10'-10" 1'-4" 12' 12' 10'-10" 2 1'-4" 12' 12' 2 1'-4"
2L9 2'-4" 1' 3' 2' 5' 4'-3"

B BULK HEAD LIGHT


4 2L10
4' 5'-1"
UP 3' 4'-6" 4'-6" 4'-6"
3L7 3L4 1L5 1L5 EXHAUST FAN
3 2
3 3 3 3 3 3 MAIN LT PANEL BOARD
1'-9" 2' 2'
12' 4' 2L7 12' 4'
2L4 1' FLOOR DISTRIBUTION BOARD
2L3 3L5 3L6 1L4 3L5 3L6 1L4
3L4 3
3L6 1"
1'-102 2L2
2L4 2L3 15 AMP SWITCHED SOCKET
3L5 1L3 4'-8" 1L3 4'-8"
1'-3"
3 3L3 3 3
4

MDB SDB
2 1L8
2L5 3L2
2L6 2L7 13'-3" 2 1L7
ONE GANG ONE WAY SWITCH
12'-10" 6' 2L6 2 5' 12'-10" 12'-10" 6' 12'-10" 12'-10"
39' 39' 39' 3L2 2
3 UP UP 2 DN
4 4 TWO GANG ONE WAY SWITCH
3 3 3 44'
2 3L3 6' 43' 3 6'
LC#1 3
LC#3 1'-71" LC#3 LC#1 4 MULTI GANG ONE WAY SWITCH
2L2 2 1L1 1L2
LC#2 1L2 LC#2
2'-10" 2'-10"
5 1' 4 4 2L1
3 2L1 3L1 3 1L1 3 2L5 4 TWO WAY SWITCH
3L1 1'-9" 3 1L6
2 1'-2" 4 2 2 1'-2" 2 2 1'-4" 2
2'-4"
12'-10" 12'-10" TV SOCKET
4' 2
4' 3L7 1L10 1L9
3' 2L5 3'-6" 3' 2L4
2' 5 A SWITCHED SOCKET
5
LC#2
4 4 4
4 2 4 4 2 A SOCKET
5 5
1L8 1L2 4 3L9 2L3
2L4
3 2L1
13' 6' 1L6 1L4 2L4 5' 13' 13' 6' 6' 13'
2L2 TELEPHONE SOCKET
1L5 3L8
1L3
3 2L2 17'-9"
3 17' PUSH SWITCH
3
9"
LC#1 2'
2'-10" 3'-4" 2'-10" LC# LIGHT CIRCUIT NUMBER
3L10 10"
1L7
1 1'-2" 1'-2" 1 1 1'-2" 1'-2" 1 1L1 LIGHT CIRCUIT #1, SWITCH 1
3
1L1 3 2L10
2L9 2L8 5" 1L2 LIGHT CIRCUIT #1, SWITCH 2
4' 1'-3" 1'-2" 10" 2' 2' 2' 2' 2' 1'-10" 1'-2" 4' 5' 4' 3' 2' 2' 2' 2' 2' 2' 4' 4' 1'-2" 8'-6" 1'-2" 6' 1'-2" 6' 1'-2" 6' 1'-2" 6' 1'-2" 6'-3" 9"

5" PC# POWER CIRCUIT NUMBER


UP 29'
15' 1'-2" 2' 2' 2' 2' 2' 2' 2'-2" 12'-4" 2'-4" 11' 2' 1'-2" 12'-8" 1'-2" 9" 11'-6" 9" 1'-2" 12'-8" 1'-2" 4'
13'-10" 14'-2" 13'-10" 13'-10" 14'-2" 13'-10"
13'-10" 14'-2" 13'-10"
48'-3" 47'
47' NEA-METER
A B C D A B C D A B C D
M
ELECTRICAL LAYOUT ELECTRICAL LAYOUT
LIGHT CIRCUIT LIGHT CIRCUIT 30 AMP TP MCCG
ELECTRICAL LAYOUT (FIRST FLOOR PLAN) (SECOND FLOOR PLAN)
10 SWG BASE EARTH BUS
(USED AS DP MCCB)
LIGHT CIRCUIT COPPER WIRE
(GROUND FLOOR PLAN)
6A 6A 6A 6A 16A 16A 16A 16A 25A 25A SINGLE POOL
DOUBLE POOL

TO SBD-2

TO SBD-3
SPACE

SPACE
PC1

PC2

PC3
LC1

LC2

LC3
MCB
EARTH ELECTRODE

SDB-1 AT GROUND FLOOR

2 NOS. OF 2 10 + 1 NOS. OF 2 22 COPPER WIRE

25AMP DP MCB
6A 6A 6A 6A 16A 16A 16A 16A
25AMP DP MCB

SPACE
16A SP MCB

SPACE

PC1

PC2

PC3
LC1

LC2

LC3
SDB-2 AT FIRST FLOOR

6A
SP MCB
6A 6A 16A 16A 6A

SPACE

SPACE
PC1

PC2
LC1

LC2
SDB-3 AT SECOND FLOOR

DETAIL OF DISTRIBUTION SYSTEM

A B C D A B C D A B C D

49'
48'-3"
48'-3" 13'-10" 14'-2" 13'-10"
13'-10" 14'-2" 13'-10" 13'-10" 14'-2" 13'-10"
2' 1'-2" 12'-8" 1'-2" 1'-4" 11'-8" 2' 3'-9" 5' 4'-3" 1'-3" 1'-4" 1'-5"
1'-2" 5'-10" 5' 1'-10" 1'-2" 9'-11" 9" 1' 9" 3' 2' 7'-6" 1'-9" 4' 1'-3" 1'-2" 5'-10" 5' 3' 1'-4" 11'-8" 2' 1'-9" 2' 7'-6" 4'-3" 1'-3" 1'-4" 1'-5"
1'
4 1'-2"
2'
4 4 1'-2"
2'
4 4 1'-2" 4
8"

2'-6" UP
7'-2"
3'-6"
4'-2" 5'-9" 5'-10" 5'-11"
2' 4'-7"
1' 2'
4" 9"
11'-11"10'-10" 1'-4" 12' 12' 10'-10" 1'-4" 12' 12' 1'-4"
2'-4" 1' 3' 2' 5' 4'-3"

4' 5'-1"
3' UP 3' 4'-6" 4'-6" 4'-6"
9"5" PC#3
PC#3

3 1'-9" 3 3 2'
3 3 2'
3
4' 1' 4'

1"
1'-102
4'-8" 4'-8"
1'-3"
MDB SDB

13'-3"
12'-11" 6' 5' 12'-10" 12'-10" 6' 12'-10" 12'-10"
39' 39' 39'
UP UP DN
44'
6' 43' 6'
PC#1
1"
1'-72 PC#1
PC#2 PC#2
2'-10" 2'-10"
1'

1'-9" 1'-4"
2 1'-2" 2 2 1'-2"
2'-4"
2 2 2
4'
3' 4' 3'
3'-6" 2'

PC#2

13' 6' 5' 13' 13' 6' 6' 13' OWNER SIGNATURE

17'-9"
17'
PC#1
9"
3'-4" 2'
2'-10" 2'-10"
10"
1 1'-2" 1'-2" 1 1 1'-2" 1'-2" 1 BUILDING TYPE:- LOCATION:-
5"
RESIDENTAL SITAPAILA-1, KATHMANDU
4' 1'-3" 1'-2" 10" 2' 2' 2' 2' 2' 1'-10" 1'-2" 4' 5' 4' 3' 2' 2' 2' 2' 2' 2' 4' 4' 1'-2" 1'-2" 6' 1'-2" 6' 1'-2" 6' 1'-2" 6' 1'-2" 6'-3" 9"

5" AREA:-1280.1380 m.sq


UP 29' PLOT No.:- 31 (2-6-3-1.53)
15' 1'-2" 2' 2' 2' 2' 2' 2' 2'-2" 12'-4" 2'-4" 11' 2' 1'-2" 12'-8" 1'-2" 9" 11'-6" 9" 1'-2" 12'-8" 1'-2" 4'
13'-10" 14'-2" 13'-10" 13'-10" 14'-2" 13'-10"
13'-10" 14'-2" 13'-10"
48'-3" 47'
47'
DETAILS
A B C D A B C D A B C D ELECTRICAL DRAWING OF BUILDING
DRAWN BY:- CHECKED BY:-
ELECTRICAL LAYOUT ELECTRICAL LAYOUT ELECTRICAL LAYOUT
POWER CIRCUIT POWER CIRCUIT POWER CIRCUIT
(GROUND FLOOR PLAN) (FIRST FLOOR PLAN) (SECOND FLOOR PLAN) Date: Scale: Registration No.
2072 -11-21 AS SHOWN

SHEET No.:E-01