01/04/2021
Fundamental Principles of
Exposure and Image
Evaluation
Ms. Danica P. Pardalis, R.R.T.
Lecturer, B.S. Radiologic Technology Program
La Consolacion University Philippines
COURSE OUTLINE:
V. Fundamental Principles of Exposure
1. Optimal receptor exposure
1.1. Milliampere-seconds (mAs)
1.2. kVp
1.3. Collimation
1.4. Grid
1.5. Source-to-image distance (SID)
1.6. Speed class
1.7. Fog
2. Exposure myths and misconceptions associated with
digital systems
COURSE OUTLINE:
V. Fundamental Principles of Exposure
3. Control patient exposure
3.1. Higher kVp levels
3.2. Additional filtration
3.3. Interfacing with automatic exposure control (AEC)
systems
3.4. As low as reasonably achievable (ALARA) principles
4. Monitor patient exposure
4.1. Part of quality assurance (QA) program
4.2. Vendor-supplied software
1
01/04/2021
COURSE OUTLINE:
VI. Image Evaluation
1. Evidence of appropriate exposure level (exposure indicator range)
1.1. Exposure indicator range
1.2. Noise
1.2.1. Computer noise
1.2.2. Electronic noise
1.2.3. Material mottle
1.2.4. Quantum mottle
2. Contrast
3. Recorded detail
4. Artifacts
4.1. Patient
4.2. Equipment
4.3. Exposure
4.4. Processing
4.5. Moiré effect 4
LEARNING OBJECTIVES:
a. Apply the fundamental principles to digital detectors
b. Determine potential impact of digital radiographic
systems on patient exposure and the application of the
ALARA concept in a digital system
c. Associate impact of image processing parameters to the
image appearance
d. Evaluate the effect of a given exposure change on
histogram shape, data width and image appearance and
describe the conditions that cause quantum mottle in a
digital image;
OPTIMAL RECEPTOR EXPOSURE
◼ Milliampere-seconds (mAs)
❑ Controls the radiographic density
❑ Controls the quantity of x-rays produced
❑ Controls the duration of exposure
❑ Quantity of exposure is directly proportional to exposure time
2
01/04/2021
OPTIMAL RECEPTOR EXPOSURE
OPTIMAL RECEPTOR EXPOSURE
◼ Kilovoltage peak (kVp)
❑ Controls the radiographic contrast
❑ Controls the quantity and quality of x-rays beam
OPTIMAL RECEPTOR EXPOSURE
◼ Collimation
❑ Affects the radiographic contrast
❑ Restricts the field of view
❑ Reduced the patient dose
3
01/04/2021
OPTIMAL RECEPTOR EXPOSURE
◼ Grid
❑ Affects the radiographic contrast
❑ Reduced the scattered radiation
❑ Increases the patient dose
10
OPTIMAL RECEPTOR EXPOSURE
◼ Source to image receptor distance (SID)
❑ Affects the density and intensity of the x-ray beam
❑ Quantity of exposure is inversely proportional to the square of
the distance
11
OPTIMAL RECEPTOR EXPOSURE
12
4
01/04/2021
OPTIMAL RECEPTOR EXPOSURE
13
OPTIMAL RECEPTOR EXPOSURE
14
EXPOSURE MYTHS AND
MISCONCEPTION
◼ Must be highly maintained
◼ Increase patient exposure
◼ Increase radiation dose
◼ Increase scatter radiation
15
5
01/04/2021
16
CONTROL PATIENT EXPOSURE
◼ Higher kVp levels
◼ Additional filtration
◼ AEC Systems
◼ ALARA Principle
17
Appropriateness of Exposure level
◼ Technique charts are based on the “average
patient”
◼ The thicker the part the more x-radiation is
required to penetrate. Calipers should be used
◼ Keep in mind not only the measurement but the
type of tissue you need to penetrate (fat vs
muscle)
18
18
6
01/04/2021
Technique
◼ In general, Soft tissue = low kVp and high
mAs
◼ Extremity (soft tissue & bone) = low kVp
◼ Chest (high subject contrast) = high kVp
◼ Abdomen (low subject contrast) = middle kVp
19
19
Pathology
◼ Can appear with increased radiolucency or
radiopacity
◼ Some pathology is destructive causing tissue
to be radiolucent
◼ Others can be additive causing tissue to be
radiopaque
20
20
Image Quality
• Is the exactness of the representation of
the patient’s anatomy
• 3 major factors affecting image quality that
is under the control of the technologist:
Image Receptor selection/use, Geometric
factors & Subject factors.
21
7
01/04/2021
Judging Image Quality
• The most important characteristic of
radiographic quality are: Spatial
Resolution, Contrast Resolution, Noise &
Artifacts
22
23
Main Factors Affecting
Recorded Detail
• kVp & mAs • Material
• Motion Unsharpness/ Film
• Object Screen Combo
Unsharpness • Focal Spot Size
• SID (Source to • MTF (modulation
Image Distance) transfer function)
• OID (Object to
Image Distance)
24
8
01/04/2021
25
Recorded Detail
• Other names:
- detail
-sharpness of detail
-definition
-resolution
-degree of noise
- visibility of detail
26
27
9
01/04/2021
28
29
30
10
01/04/2021
Modulation Transfer Function
• The ability of a system to record available
spatial frequencies.
• The sum of the components in a recording
system cannot be greater than the system
as a whole.
• When any component’s function is
compromised because of some type of
interference, the overall quality of the
system is affected.
31
Contrast Resolution
• Is the ability to distinguish anatomic
structures of similar subject contrast. Ex:
liver-spleen, gray matter-white matter
• Magnetic Resonance Imaging has the
highest contrast resolution
• Computed Tomography is excellent as
well
32
33
11
01/04/2021
The contrast of an object is expressed relative to
its surrounding background.
That is what determines its visibility.
34
35
36
12
01/04/2021
37
38
“Noise”
• Borrowed from electrical engineering
• Audio noise = hum or flutter heard from a
stereo
• Video noise = “snow” on a TV
• Radiographic noise = random fluctuation
on the OD of the image
39
13
01/04/2021
QUANTUM MOTTLE
Not enough PHOTONS – can create a mottled or grainy
image - MORE COMMON IN CR SYSTEMS
40
Radiographic noise
41
Quantum mottle
42
14
01/04/2021
43
44
F/S vs Digital
Dynamic Range
45
15
01/04/2021
46
Image quality control:
Matrix size is determined by . . .
• Receptor size (Field of View: FOV)
• Pixel size
• CR - Sampling frequency
• DR - DEL size
47
48
16
01/04/2021
49
50
51
17
01/04/2021
Sampling Frequency
• The sampling frequency is the rate at
which the laser extracts the image data
from the plate.
52
53
Signal Sampling Frequency
Good sampling under sampling
54
18
01/04/2021
Nyquist Frequency
• The Nyquist Frequency will be ½ of the sampling
frequency.
• A plate that is scanned using a sampling
frequency of 10 pixels per millimeter would not
be able to demonstrate more than 5 line pairs
per millimeter based upon the Nyquist
Frequency.
• The Nyquist Frequency allows the determination
of the spatial resolution for a given sampling
frequency.
55
56
57
19
01/04/2021
58
59
60
20
01/04/2021
61
Questions?
62
REFERENCES:
1. Bushberg, J., Seibert, J.A., Leidholdt, Jr., E.,
Boone, J. (2012). The Essential Physics of Medical
Imaging. 2nd Edition. Philadelphia Lippincott
Williams & Wilkins.
2. Bushong, Stewart C. (2013). Radiologic Science
for Technologist: Physics, Biology, and Protection.
10th Edition. Mosby.
63
21