GENERAL DESCRIPTION
The Versa NAMUR mount control valves are high flow, bubbletight, direct acting or solenoid/pilot operated. They are designed
to mount directly to any NAMUR actuator, thus reducing actuator response time and cost of tubing, fittings, brackets, and labor.
These valves are available in two materials - Aluminum and 316L stainless steel.
E5 is a direct acting 3-way (3/2) solenoid valve. C5 and C316 are solenoid/pilot operated high flow, 5-port NAMUR valves. They
are available as single or double solenoid 2-position (C5 - C316) and 3-position (C5) models. Single solenoid spring return
models utilize an air assisted spring return feature, assuring a positive return. Double solenoid valves may be used in applications
where a momentary signal is required or in a “fail in last shifted position” actuator application.
A complete selection of electrical connections, area classifications, and power requirements makes the most exacting and
demanding specifications or applications easy to satisfy.
2 www.versa-valves.com
DIRECT MOUNT ACTUATOR VALVES
VALVE PRODUCT NUMBER SELECTOR
1/4 NPT
3/2 IN EX
E5SM-3011-34-NB1-†-(coil code)
3-Way 1/4 NPT * All valves include O ring interface seals and #10-24 mounting screws. E5 & C5: For #10-32 screws
E5 .08 change NB1 to NB2. For M5 screws change NB1 to NB3. C316 NUMAR: For #10-32 screws change
3/2 NE1 to NE2. For M5 screws change NE1 to NE3.
**3-way is the same body configuration as the 4-way, but has the cylinder port plug in the 3-way
position. See "Note" in C5 section below for description.
† Add suffix option here if required, For coil code see page 4.
B
END VIEW 1/4” NPT (G1/4)
B A C TOP VIEW VENT PORT
Series C316
Typical CGS-4332-316-NE1-XMA_-A120 Typical CGS-4332-316-NE1-U-XDB_-A120
Typical CGS-4332-316-NE1-XX-A120 Top View Top View
Top View
ERSA ®
PARAMUS NJ 07652 U.S.A.
B
B B
A A
Side View Typical CGG-4332-316-NE1-U-XDB_-A120
C Side View
Typical CGG-4332-316-NE1-XMA_-A120
Side View
A
C
Typical CGG-4332-316-NE1-XX-A120 C
Side View
A A
-U-XMAA* Ex e mb II T5, T6 Gb
(mb) Encapsulation IECEx IP66
-U-XMAF* Ex tD A21 T100ºC, T85ºC Db
(e) Increased Safety &
-U-XMFA* (tD) Tight Dust II 2 G Ex e mb II T5, T6 ATEX IP67
-U-XMFF* II 2D Ex tD A21 T100ºC, T85ºC
OPTIONS
Solenoid Vent Options
4 www.versa-valves.com
ELECTRICAL
Voltage Electrical
(Power) Characteristics Miscellaneous
All usual 50 Hz & 60 Hz AC (6W) Steel cover with 1/2 NPT conduit hub.
All usual DC (7W)
24V60, 120V60, 240V60 (8.5W) Class F epoxy molded coil Mini DIN socket with PG9 cable gland (-HC) or 1/2” conduit hub
24V50, 110V50, 220V50 (8.5W) (155ºC). (-HCC).
12VDC, 24VDC, 48VDC (10.5W) Continuous duty, 2 leads 24”
(60 cm).
24V60, 120V60, 240V60 (8.5W) Epoxy encapsulated coil with steel 1/2 NPT conduit hub.
24V50, 110V50, 220V50 (8.5W)
12VDC, 24VDC, 48VDC (10.5W
Voltage Electrical
Miscellaneous
(Power) Characteristics
All usual 50 Hz & 60 Hz AC (5.6W) Plated steel coil housing with 1/2 NPT conduit entry.
All usual DC (7.2W) For stainless steel (430 type) coil housing add: (-ST)
12V60, 24V60, 48V60, 120V60, 240V60 Plated steel coil housing with 1/2 NPT conduit entry. For stainless steel
(1.8W) (430 type) coil housing add: (-ST) Maximum pilot pressure 120 psi (8
6VDC, 12VDC, 24VDC, 48VDC (1.8W) bar). 1.8W nominal power.
Class F epoxy molded coil (155ºC).
continuous duty. Plated steel coil housing with M20 x 1.5 conduit entry.
All usual 50 Hz & 60 Hz AC (5.6W)
3 leads 24” (60 cm). Ground terminal on cover.
All usual DC (7.2W) For stainless steel (430 type) coil housing add: (-ST)
12V60, 24V60, 48V60, 120V60, 240V60 Plated steel coil housing with M20 x 1.5 conduit entry.
Ground terminal on cover.
(1.8W)
For stainless steel (430 type) coil housing add: (-ST)
6VDC, 12VDC, 24VDC, 48VDC (1.8W) Maximum pilot pressure 120 psi (8 bar) 1.8W nominal power.
Continuous duty coil & rectifier, in- Thick wall epoxy coil housing with integral
24VDC (4W)
cluding surge suppression, potted junction box. Internal ground terminal.
(Consult factory for other voltage)
within housing. M20 x 1.5 conduit entry: (-XMAA), (-XMFA),
Cable gland for 6-12 mm ø cable: (-XMAE), 1/2 NPT conduit entry with
24VDC (10W inrush, 2.6W holding) Continuous duty coil & power adapter: (-XMAF), (-XMFF)
(Consult factory for other voltages) controller potted within housing.
Requires the use of an approved safety barrier or isolator.
24VDC (0.8W) Continuous duty Coil and power Thick wall epoxy coil housing and integral junction box. Internal ground
(Consult factory for other voltages) controller potted within housing. terminal. M20 x 1.5 conduit entry: (-XIFA), Cable gland for 6-12 mm ø
cable: &1/2 NPT conduit entry with adapter: (-XIFF)
Options
Overrides Solenoid Orientation
C5 Valves* C316 Valves C316 Valves
6 www.versa-valves.com
DIRECT MOUNT ACTUATOR VALVES
Accessories
Versa NAMUR ReBreather Versa Dual Speed Control
Actuator Controls For Harsh Or Dirty Environments Actuator Controls For Harsh Or Dirty Environments
Introduction Description
A valve accessory to protect valves and actuators from harsh A simple device to control actuator speed in applications where
and corrosive atmospheres. Designed to prevent the actuator the environment is corrosive from production, plant pollutants
spring chambers from sucking in external air and contaminants or other environmental issues. The Dual Speed Control
during the return stroke. Accessory protects the actuator package from external air and
contaminants.
How it works
The Rebreather block is used on single acting actuators to How it works
prevent corrosive atmosphere from entering the actuator The Versa Dual Speed Control block is used on double acting
spring side. This add-on accessory is also designed to use actuators to prevent corrosive atmosphere from entering the
available instrument air to fill spring side, thus assuring only valve package (actuator and solenoid NAMUR valve). This add-
clean air enters the actuator. on accessory includes 2 of Versa’s proven “Bleed Controls” to
allow independent adjusting of open and close speeds.
The instrument air it utilizes on the return stroke is from the
exhaust cycle of the piston side of actuator. No additional air
is required to complete the cycle and keep the actuator clean,
hence the reason this accessory is called a “ReBreather”
reusing clean exhaust air to keep the actuator clean. CGS-3331-316-NX1-DBC2-HCC-D024
Shown
CGS-3331-316-NE1-RB5-XX-D024
Shown
ORDERING INFORMATION
As a Kit As a Kit
C Series C 316 Series Description C Series (-NB/-NX) C 316 Series (-NE) Description
C-33RB-NB C-33RB-NE Plate, ¼” npt vent port open Plate and speed controls with ¼”
C-43SC-NB C-43SC-NE
Plate, and speed control, with ¼” npt vent port open**
C-33RB-NB-BC C-33RB-NE-BC npt vent port open Plate and speed controls with
C-43SC-NB-DB3 C-43SC-NE-DE3 DE-3 in vent port**
C-33RB-NB-DE3 C-33RB-NE-DE3 Plate, with DE-3 in vent port**
Plate, and speed control, with
C-33RB-NB-BC-DE3 C-33RB-NE-BC-DE3 DE-3 in vent port
C-33RB-NB-MFS3 C-33RB-NE-MFS3 Plate, with MFS-3 in vent port
Plate, and speed control, with
C-33RB-NB-BC-MFS3 C-33RB-NE-BC-MFS3 MFS-3 in vent port
On a Valve On a Valve
Suffix* Description Suffix* Description Suffix* Description
Plate, ¼” npt vent port -RB1 Plate, and speed control, with -DBC Plate and speed controls with ¼” npt vent port† for -NE valves
-RB open ¼” npt vent port open -DBC1 Plate and speed control with ¼” npt vent port† for NB/-NX valves
-RB2 port**with DE-3 in vent
Plate, -RB3 Plate, and speed control, with -DBC2 Plate and speed control with DE-3 in vent port for -NB/-NX valves
DE-3 in vent port
-DBC3 Plate and speed control with DE-3-316 in vent port for -NE valves
-RB4 Plate, with MFS-3 in vent -RB5 Plate, and speed control, with
port MFS-3 in vent port *Add suffix to complete C/C316 series valve part number.
**Aluminum DE on C Series and Stainless on C-316 Series
† Customer supplied excluder
Actuator, Actuator,
Spring Return Double Acting
www.versa-valves.com 7
Versa
has been
supplying the
oil and gas
industr y with
pneumatic
and hydraulic
components
for over 50
years. We
have built a
reputation
for quality
that is
unsur passed
in the market
for high
perfor mance
solenoids,
pneumatic
relays, resets
and pilot
valves
The warnings below must be read and reviewed before designing a system utilizing,
installing, servicing, or removing a Versa product. Improper use, installation or servicing of LIMITED WARRANTY DISCLAIMER
a Versa product could create a hazard to personnel and property. AND LIMITATION OF REMEDIES
DESIGN APPLICATION WARNINGS Versa’s Series products are warranted
Versa products are intended for use where compressed air or industrial hydraulic fluids are to be free from defective material and
present. For use with media other than specified or for non-industrial applications or other workmanship for a period of ten years
applications not within published specifications, consult Versa. from the date of manufacture, provided
Versa products are not inherently dangerous. They are only a component of a larger said products are used in accordance
system. The system in which a Versa product is used must include adequate safeguards with Versa specifications. Versa’s
to prevent injury or damage in the event of system or product failure, whether this failure liability pursuant to that warranty
be of switches, regulators, cylinders, valves or any other system component. System is limited to the replacement of the
designers must provide adequate warnings for each system in which a Versa product
is utilized. These warnings, including those set forth herein, should be provided by the Versa product proved to be defective
designer to those who will come in contact with the system. provided the allegedly defective
product is returned to Versa or its
Where questions exist regarding the applicability of a Versa product to a given use, inquiries authorized distributor. Versa provides
should be addressed directly to the manufacturer. Confirmation should be obtained directly
from the manufacturer regarding any questioned application prior to proceeding. no other warranties, expressed or
implied, except as stated above.
INSTALLATION, OPERATION AND SERVICE WARNINGS There are no implied warranties
Do not install or service any Versa product on a system or machine without first of merchantability or fitness for a
depressurizing the system and turning off any air, fluid, or electricity to the system or
machine. All applicable electrical, mechanical, and safety codes, as well as applicable particular purpose. Versa’s liability for
governmental regulations and laws must be complied with when installing or servicing a breach of warranty as herein stated is
Versa product. the only and exclusive remedy and in
no event shall Versa be responsible or
Versa products should only be installed or serviced by qualified, knowledgeable personnel
who understand how these specific products are to be installed and operated. The liable for incidental or consequential
individual must be familiar with the particular specifications, including specifications for damages.
temperature, pressure, lubrication, environment and filtration for the Versa product which
is being installed or serviced. Specifications may be obtained upon request directly from
Versa. If damages should occur to a Versa product, do not Operate the system containing
the Versa product. Consult Versa for technical information.