CYME's CYMCAP version 8.2 cable thermal rating software includes new features such as a submarine cable installation module, improved calculations for cables near magnetic materials, and HVDC cable rating considering electrical stress. The software also features graphical user interface enhancements, reporting improvements, and a cable impedance module. The software builds on 30 years of development as a worldwide reference for cable thermal rating calculations.
CYME's CYMCAP version 8.2 cable thermal rating software includes new features such as a submarine cable installation module, improved calculations for cables near magnetic materials, and HVDC cable rating considering electrical stress. The software also features graphical user interface enhancements, reporting improvements, and a cable impedance module. The software builds on 30 years of development as a worldwide reference for cable thermal rating calculations.
CYME's CYMCAP version 8.2 cable thermal rating software includes new features such as a submarine cable installation module, improved calculations for cables near magnetic materials, and HVDC cable rating considering electrical stress. The software also features graphical user interface enhancements, reporting improvements, and a cable impedance module. The software builds on 30 years of development as a worldwide reference for cable thermal rating calculations.
CYME's CYMCAP version 8.2 cable thermal rating software includes new features such as a submarine cable installation module, improved calculations for cables near magnetic materials, and HVDC cable rating considering electrical stress. The software also features graphical user interface enhancements, reporting improvements, and a cable impedance module. The software builds on 30 years of development as a worldwide reference for cable thermal rating calculations.
builds on 30 years of development as the worldwide reference in cable thermal rating calculations
New features for cable ampacity software
Following clean Submarine cable installation add-on module Improved calculations for cables in presence of magnetic materials This add-on module supports a new set of energy trends and submarine cable installations: Several improvements in the methodology used integrating the latest • Cables immersed in water to compute Eddy currents and hysteresis losses for installations containing magnetic materials. advances in cable • Cables on the seabed thermal rating, • Cables in the silt (submarine soil) HVDC cable rating considering electrical stress the new CYMCAP • J-tubes CYMCAP power cable rating calculation for HVDC cables is now performed considering the electric version 8.2 version More solutions for cable modeling field strength in the insulation. includes a new • Double-armoured cables for submarine Graphical User Interface (GUI) enhancements module for submarine installations • Better visualization of results, including cable installations as • New parameter to easily identify DC or AC cables when modeling a new cable ampacity and temperature results summarized well as a wide • Extendedlist of available materials in the steady state view after a simulation
range of enhanced supported for jacket and bedding
• Cables which are directly buried in ducts and pipe-type cables are all supported through the capabilities and Proven, reliable results — same icon new functionalities. CIGRE TB 880 validation • Validation of minimum depth for various elements (duct bank, backfill, ducts) CIGRE WG B1.56 published TB 880 Power Cable Rating Examples for Calculation Tool Verification • The Comments section in the “New study/ in September 2022. A document comparing the execution” dialog box now allows up to results and the instructions to reproduce the 200 characters cases is now available in the Help menu. • Readme file is now available through the Help menu • Limitation to run transient simulations with no more than 45 cables was removed. Report enhancements Detailed cable impedance add-on module enhancements • Increased efficiency exporting results to Microsoft Excel • Impedance calculation for three core cables (non-magnetic) is • More meaningful information in the electrical parameters and now supported steady state reports, including formulas for installations with dissimilar cables SOUTHWIRE cable library • Print is now easier with a new general report containing the most CYMCAP software now contains a library with almost 500 cables. relevant information for cables and installation in a vertical format This library was provided directly from SOUTHWIRE and is available with the default database included with the installation. Multiple casings add-on module enhancements • Improved differentiation between casings on the seabed and those that are installed in the silt (submarine soil) • Metallic casings with magnetic properties are now supported • More cable configurations including multiple cables per phase are now supported with this add-on module
Users can learn more about CYMCAP 8.2 by downloading the
Readme document and the reference manual available at my.cyme.com/downloads/software. A license upgrade is required to run this version. Collect the C2V file from the license manager and send it to the support email [email protected]. For more information on CYMCAP software, or for a web demo, please contact us at [email protected].