AGN2004H
AGN2004H
ORDERING INFORMATION
AGN 2 0
Contact arrangement
2: 2 Form C
Operating function
0: Single side stable
1: 1 coil latching
6: High sensitivity single side
stable type
Type of operation
0: Standard type (B.B.M.)
Terminal shape
Nil: Standard PC board terminal
A: Surface-mount terminal A type
S: Surface-mount terminal S type
Nominal coil voltage (DC)
1H: 1.5V 03: 3V 4H: 4.5V 06: 6V 09: 9V
12: 12V 24: 24V
Packing style*1
Nil: Tube packing
X: Tape and reel packing (picked from 1/2/3/4-pin side)
W: Tape and reel packing (picked from the 1/2/3/4-pin side)
With humidity indicator and silica gel in moisture proof bag
Z: Tape and reel packing (picked from 5/6/7/8-pin side)
Y: Tape and reel packing (picked from the 5/6/7/8-pin side)
With humidity indicator and silica gel in moisture proof bag
Note 1) The “W” and “Y” at the end of the part number only appears on the inner and outer packing.
It does not appear on the relay itself.
2. Surface-mount terminal
7XEHSDFNLQJ
6LQJOHVLGHVWDEOH FRLOODWFKLQJ +LJKVHQVLWLYLW\VLQJOHVLGHVWDEOH
1RPLQDOFRLOYROWDJH
3DUW1R 3DUW1R 3DUW1R
9'& $*1Ƒ+ $*1Ƒ+ $*1Ƒ+
9'& $*1Ƒ $*1Ƒ $*1Ƒ
9'& $*1Ƒ+ $*1Ƒ+ $*1Ƒ+
9'& $*1Ƒ $*1Ƒ $*1Ƒ
9'& $*1Ƒ $*1Ƒ $*1Ƒ
9'& $*1Ƒ $*1Ƒ $*1Ƒ
9'& $*1Ƒ $*1Ƒ $*1Ƒ
Ƒ)RUHDFKVXUIDFHPRXQWHGWHUPLQDOLGHQWL¿FDWLRQLQSXWWKHIROORZLQJOHWWHU$W\SH$6W\SH6
6WDQGDUGSDFNLQJ7XEHSFV&DVHSFV
7DSHDQGUHHOSDFNLQJ
6LQJOHVLGHVWDEOH FRLOODWFKLQJ +LJKVHQVLWLYLW\VLQJOHVLGHVWDEOH
1RPLQDOFRLOYROWDJH
3DUW1R 3DUW1R 3DUW1R
9'& $*1Ƒ+= $*1Ƒ+= $*1Ƒ+=
9'& $*1Ƒ= $*1Ƒ= $*1Ƒ=
9'& $*1Ƒ+= $*1Ƒ+= $*1Ƒ+=
9'& $*1Ƒ= $*1Ƒ= $*1Ƒ=
9'& $*1Ƒ= $*1Ƒ= $*1Ƒ=
9'& $*1Ƒ= $*1Ƒ= $*1Ƒ=
9'& $*1Ƒ= $*1Ƒ= $*1Ƒ=
Ƒ)RUHDFKVXUIDFHPRXQWHGWHUPLQDOLGHQWL¿FDWLRQLQSXWWKHIROORZLQJOHWWHU$W\SHA6W\SHS
6WDQGDUGSDFNLQJ7DSHDQGUHHOSFV&DVHSFV
1RWHV7DSHDQGUHHOSDFNLQJV\PERO³=´LVQRWPDUNHGRQWKHUHOD\³;´W\SHWDSHDQGUHHOSDFNLQJ SLFNHGIURPSLQVLGH LVDOVRDYDLODEOH
7DSHDQGUHHOSDFNLQJV\PERO³<´LVQRWPDUNHGRQWKHUHOD\³:´W\SHWDSHDQGUHHOSDFNLQJ SLFNHGIURPSLQVLGH LVDOVRDYDLODEOH
3OHDVHLQTXLUHLI\RXUHTXLUHDUHOD\EHWZHHQDQG9'&ZLWKDYROWDJHQRWOLVWHG
RATING
1.Coil data
2SHUDWLQJFKDUDFWHULVWLFVVXFKDVµ2SHUDWHYROWDJH¶DQGµ5HOHDVHYROWDJH¶DUHLQÀXHQFHGE\PRXQWLQJFRQGLWLRQVDPELHQW
WHPSHUDWXUHHWF
7KHUHIRUHSOHDVHXVHWKHUHOD\ZLWKLQRIUDWHGFRLOYROWDJH
µ,QLWLDO¶PHDQVWKHFRQGLWLRQRISURGXFWVDWWKHWLPHRIGHOLYHU\
6LQJOHVLGHVWDEOHW\SH
1RPLQDORSHUDWLQJ
1RPLQDOFRLO 3LFNXSYROWDJH 'URSRXWYROWDJH &RLOUHVLVWDQFH 1RPLQDORSHUDWLQJ 0D[DSSOLHGYROWDJH
FXUUHQW
YROWDJH DW&)) DW&)) >@ DW&)) SRZHU DW&))
>@ DW&))
1.5 9'& P$ ȍ
9'& 46.7 mA ȍ
9'& 31 mA ȍ 9RI
9RUOHVVRI 9RUPRUHRI 140 mW
9'& 23.3 mA ȍ QRPLQDOYROWDJH
QRPLQDOYROWDJH QRPLQDOYROWDJH
9'& ,QLWLDO ,QLWLDO 15.5 mA ȍ
9'& 11.7 mA ȍ
9RI
9'& 9.6 mA ȍ 230 mW
QRPLQDOYROWDJH
FRLOODWFKLQJW\SH
1RPLQDORSHUDWLQJ
1RPLQDOFRLO 6HWYROWDJH 5HVHWYROWDJH &RLOUHVLVWDQFH 1RPLQDORSHUDWLQJ 0D[DSSOLHGYROWDJH
FXUUHQW
YROWDJH DW&)) DW&)) >@ DW&)) SRZHU DW&))
>@ DW&))
1.5 9'& 66.7 mA ȍ
9'& 33.3 mA ȍ
9'& 9RUOHVVRI 9RUOHVVRI 22.2 mA ȍ
100 mW 9RI
9'& QRPLQDOYROWDJH QRPLQDOYROWDJH 16.7 mA ȍ
QRPLQDOYROWDJH
9'& ,QLWLDO ,QLWLDO 11.1 mA ȍ
9'& P$ ȍ
9'& 5.0 mA ȍ 120 mW
3XOVHGULYH -,6&
2. Speci cations
&KDUDFWHULVWLFV ,WHP 6SHFL¿FDWLRQV
$UUDQJHPHQW )RUP&
&RQWDFW ,QLWLDOFRQWDFWUHVLVWDQFHPD[ 0D[Pȍ %\YROWDJHGURS9'&$
&RQWDFWPDWHULDO 6WDWLRQDU\FRQWDFW$J3G$XFODG0RYDEOHFRQWDFW$J3G
1RPLQDOVZLWFKLQJFDSDFLW\ $9'&$9$& UHVLVWLYHORDG
0D[VZLWFKLQJSRZHU : '& 9$ $& UHVLVWLYHORDG
0D[VZLWFKLQJYROWDJH 9'&9$&
0D[VZLWFKLQJFXUUHQW 1A
5DWLQJ 0LQVZLWFKLQJFDSDFLW\ 5HIHUHQFHYDOXH 1 ȝ$P9'&
6LQJOHVLGHVWDEOH P: WR9'& P: 9'&
1RPLQDORSHUDWLQJ +LJKVHQVLWLYLW\VLQJOHVLGH
SRZHU VWDEOHW\SH P: WR9'& P: 9'&
FRLOODWFKLQJ
0LQ0ȍ DW9'&
,QVXODWLRQUHVLVWDQFH ,QLWLDO
0HDVXUHPHQWDWVDPHORFDWLRQDV³,QLWLDOEUHDNGRZQYROWDJH´VHFWLRQ
%HWZHHQRSHQFRQWDFWV 9UPVIRUPLQ 'HWHFWLRQFXUUHQWP$
%UHDNGRZQYROWDJH
%HWZHHQFRQWDFWDQGFRLO 9UPVIRUPLQ 'HWHFWLRQFXUUHQWP$
,QLWLDO
%HWZHHQFRQWDFWVHWV 9UPVIRUPLQ 'HWHFWLRQFXUUHQWP$
6XUJHEUHDNGRZQ %HWZHHQRSHQFRQWDFWV 9 îȝV )&&3DUW
(OHFWULFDO YROWDJH ,QLWLDO %HWZHHQFRQWDFWVDQGFRLO 9 îȝV 7HOFRUGLD
FKDUDFWHULVWLFV
0D[&
7HPSHUDWXUHULVH DW&))
%\UHVLVWLYHPHWKRGQRPLQDOFRLOYROWDJHDSSOLHGWRWKHFRLOFRQWDFWFDUU\LQJFXUUHQW$
0D[PV>0D[PV@ 1RPLQDOFRLOYROWDJHDSSOLHGWRWKHFRLOH[FOXGLQJFRQWDFWERXQFH
2SHUDWHWLPH>6HWWLPH@ DW&))
WLPH
0D[PV>0D[PV@ 1RPLQDOFRLOYROWDJHDSSOLHGWRWKHFRLOH[FOXGLQJFRQWDFWERXQFH
5HOHDVHWLPH>5HVHWWLPH@ DW&))
WLPH ZLWKRXWGLRGH
)XQFWLRQDO 0LQPV2 +DOIZDYHSXOVHRIVLQHZDYHPVGHWHFWLRQWLPHȝV
6KRFNUHVLVWDQFH
0HFKDQLFDO 'HVWUXFWLYH 0LQPV2 +DOIZDYHSXOVHRIVLQHZDYHPV
FKDUDFWHULVWLFV )XQFWLRQDO WR+]DWGRXEOHDPSOLWXGHRIPP 'HWHFWLRQWLPHȝV
9LEUDWLRQUHVLVWDQFH
'HVWUXFWLYH WR+]DWGRXEOHDPSOLWXGHRIPP
0HFKDQLFDO Min. 5 × 107 DWFSP
([SHFWHGOLIH
(OHFWULFDO Min. 105 $9'&UHVLVWLYH 5 $9$&UHVLVWLYH DWFSP
$PELHQWWHPSHUDWXUH
6LQJOHVLGHVWDEOHFRLOODWFKLQJW\SH ±&WR&±)WR)
&RQGLWLRQVIRURSHUDWLRQWUDQVSRUWDQGVWRUDJH 2
&RQGLWLRQV +LJKVHQVLWLYLW\VLQJOHVLGHVWDEOHW\SH ±&WR&±)WR)
+XPLGLW\WR5+ 1RWIUHH]LQJDQGFRQGHQVLQJDWORZWHPSHUDWXUH
0D[RSHUDWLQJVSHHG DWUDWHGORDG FSP
8QLWZHLJKW $SSUR[J R]
1RWHV 7KLVYDOXHFDQFKDQJHGXHWRWKHVZLWFKLQJIUHTXHQF\HQYLURQPHQWDOFRQGLWLRQVDQGGHVLUHGUHOLDELOLW\OHYHO
WKHUHIRUHLWLVUHFRPPHQGHGWRFKHFNWKLVZLWKWKHDFWXDOORDG
5HIHUWR³$0%,(17(19,5210(17´LQ*(1(5$/$33/,&$7,21*8,'(/,1(6
REFERENCE DATA
0D[VZLWFKLQJFDSDFLW\ /LIHFXUYH 0HFKDQLFDOOLIH
7HVWHGVDPSOH$*1+SFV
2SHUDWLQJVSHHGFSP
100 4
1.0 50
3
40
Voltage, V
Min.
30 2.5
DC 30V resistive load
20 2 Drop-out voltage
Max.
1.5
0.3
Min.
AC 125V 1
10 resistive load
0.5
0 0
30 100 0.2 0.4 0.6 0.8 1.0 1.2 0 10 30 50
Contact voltage, V Switching current, A No. of operations, ×10
4
&RQWDFWUHVLVWDQFHPȍ
Temperature rise, °C
80 80
Pick-up voltage
70 Max. 70 50 1A
Min. 0A
60 60
40
50 50 1A
X 30 0A
40 Drop-out voltage 40 X
Max.
30 30 20
Min.
20 20
10
10 10
0 0 0
0 5 10 0 5 10 100 110 120 130 140 150
4 4
No. of operations, ×10 No. of operations, ×10 Coil applied voltage, %
3 3 50
Rate of change, %V
Operate time Operate time
Operate and release time, ms
Release time
Operate and release time, ms
Release time 40
2.5 2.5 30
Max. Max.
20
2 2 Drop-out x
Min. Min. voltage 10 x
Max. -40 -20 0
1.5 1.5
20 40 60 80 100
Min. -10
Max. Pick-up Ambient temperature, °C
1 1 voltage -20
Min.
-30
0.5 0.5
-40
0 0 -50
80 90 100 110 120 80 90 100 110 120
Coil applied voltage, %V Coil applied voltage, %V
10
Rate of change, %V
Rate of change, %V
10
Z X X' Deenergized condition
Z' Y Energized condition 5 5 ON
Y 1,000m/s 2 ON ON
Y' Pick-up voltage Pick-up voltage
0 0
X Z
1,000m/s2 1,000m/s2 -5 -5 ON
-10 ON -10 ON
10 10
Rate of change, %V
Rate of change, %V
OFF OFF
OFF
1,000m/s2 1,000m/s2 5 5
Drop-out voltage
Z' X' Drop-out voltage
0 0
1,000m/s2 OFF OFF
-5 -5
Y'
-10 -10 OFF
0 2 4 6 8 10 12 0 2 4 6 8 10 12
.079 .157 .236 .315 .394 .472 .079 .157 .236 .315 .394 .472
Inter-relay distance , mm inch Inter-relay distance , mm inch
3.50±0.3
0.40±0.1 .138±.012 0.25±0.1 8 7 6 5 8 7 6 5
2.20±0.15 2.20
.016±.004 .010±.004 0.85 dia. .087
.087±.006 Direction indication Direction indication
(1.50) 3.20±0.15 .033 dia.
3.20±0.15 .126±.006
(.059) .126±.006
7ROHUDQFH 'HHQHUJL]HGFRQGLWLRQ 5HVHWFRQGLWLRQ
10.60±0.3 5.70±0.3
.417±.012 .224±.012
3.20 2.20
.126 .087
(0.50) 9.00±0.3
0.25±0.1 (.020) .354±.012 Max. 10.00 3.10
$W\SH .010±.004 .394 .122 5.30
.209
0.40±0.1 3.20±0.15
.016±.004 2.20±0.15 .126±.006
.087±.006 0.80
(1.50) 3.20±0.15 .031
(.059) .126±.006 7.40±0.3
.291±.012
10.60±0.3 5.70±0.3
.417±.012 .224±.012
3.20 2.20
.126 .087
1 2 3 4 1 2 3 4
Direction indication Direction indication
'HHQHUJL]HGFRQGLWLRQ 5HVHWFRQGLWLRQ
NOTES
1. Packing style 6W\SH 2. Automatic insertion
7KHUHOD\LVSDFNHGLQDWXEHZLWKWKH 7DSHGLPHQVLRQV 7RPDLQWDLQWKHLQWHUQDOIXQFWLRQRIWKH
UHOD\RULHQWDWLRQPDUNRQWKHOHIWVLGHDV Relay polarity bar
UHOD\WKHFKXFNLQJSUHVVXUHVKRXOGQRW
VKRZQLQWKH¿JXUHEHORZ (Z type) 1.50 +0.1
0 dia.
2.00
.079
4.00 2.0 dia.
.157 .079 dia.
10.70±0.2
.421±.008 H[FHHGWKHYDOXHVEHORZ
.059 +.004 dia. 1.75 0.40
&KXFNLQJSUHVVXUHLQWKHGLUHFWLRQ$
0
.069 .016
11.50
.453 24.00±0.3
.945±.012 1^JI `RUOHVV
Orientation (indicates PIN No.1)stripe 11.10
.437
&KXFNLQJSUHVVXUHLQWKHGLUHFWLRQ%
GN relays 16.00
.630
6.3
.248 1^NJI `RUOHVV
Tape coming out direction
&KXFNLQJSUHVVXUHLQWKHGLUHFWLRQ&
General tolerance ±0.1 mm .004 inch
1^NJI `RUOHVV
Stopper (green) Stopper (red) 'LPHQVLRQVRISODVWLFUHHO A
C B
7DSHDQGUHHOSDFNLQJ mm inch
$W\SH
7DSHGLPHQVLRQV 2.0
.079
mm inch
380 dia.
13 dia. 21 dia. 14.961 dia.
Relay polarity bar .512 dia. .827 dia.
(Z type) 1.50 +0.1
0 dia.
4.00
.157
11.50
.453 80 dia. 3OHDVHFKXFNWKHSRUWLRQ
.059 +.004 dia. 1.75 3.150 dia.
2.00
$YRLGFKXFNLQJWKHFHQWHURIWKHUHOD\
0
0.40 .069
.016 .079
11.10
24.00±0.3
.945±.012
,QDGGLWLRQH[FHVVLYHFKXFNLQJSUHVVXUH
WRWKHSLQSRLQWRIWKHUHOD\VKRXOGEH
.437
2.00 dia.
10.70±0.2 GN relays
.079 dia. 16.00
.630
8.00
.315
DYRLGHG
.421±.008
Tape coming out direction
General tolerance ±0.1 mm .004 inch
Temperature/Humidity
:KHQWUDQVSRUWLQJRUVWRULQJUHOD\VZKLOHWKH\DUHWXEH
SDFNDJHGWKHUHDUHFDVHVWKHWHPSHUDWXUHPD\GLႇHU
IURPWKHDOORZDEOHUDQJH,QWKLVFDVHEHVXUHWRFKHFNWKH
LQGLYLGXDOVSHFL¿FDWLRQV
$OVRDOORZDEOHKXPLGLW\OHYHOLVLQÀXHQFHGE\WHPSHUDWXUH
SOHDVHFKHFNFKDUWVVKRZQEHORZDQGXVHUHOD\VZLWKLQ
PHQWLRQHGFRQGLWLRQV $OORZDEOHWHPSHUDWXUHYDOXHV
6LQJOHVLGHVWDEOHFRLOODWFKLQJW\SH
Humidity (%RH)
85
Allowable range
Avoid icing Avoid con-
when used at densation when
temperatures used at tem-
lower than 0°C peratures higher
than 0°C
5
-40 0 85
Temperature(°C)
+LJKVHQVLWLYLW\ VLQJOHVLGHVWDEOHW\SH
Humidity (%RH)
85
Allowable range
Avoid con-
Avoid icing densation when
when used at used at tem-
temperatures peratures higher
lower than 0℃ than 0℃
5
-40 0 70
Temperature(°C)
For cautions for use, please read “GUIDELINES FOR RELAY USAGE”.
https://industrial.panasonic.com/ac/e/control/relay/cautions_use/index.jsp
Precautions for Coil Input
Long term current carrying Temperature rise due to pulse voltage
A circuit that will be carrying a current continuously for long periods When a pulse voltage with ON time of less than 2 minutes is used, the
without relay switching operation. (circuits for emergency lamps, alarm coil temperature rise bares no relationship to the ON time. This varies
devices and error inspection that, for example, revert only during with the ratio of ON time to OFF time, and compared with continuous
malfunction and output warnings with form B contacts) Continuous, current passage, it is rather small. The various relays are essentially
long-term current to the coil will facilitate deterioration of coil insulation the same in this respect.
and characteristics due to heating of the coil itself.
Current passage time (%)
For circuits such as these, please use a magnetic-hold type latching
For continuousu passage Tempereture rise value is 100%
relay. If you need to use a single stable relay, use a sealed type relay
ON : OFF = 3 : 1 About 80%
that is not easily affected by ambient conditions and make a failsafe
circuit design that considers the possibility of contact failure or ON : OFF = 1 : 1 About 50%
disconnection. ON : OFF = 1 : 3 About 35%
DC Coil operating power
Steady state DC current should be applied to the coil. The wave form ON : OFF = 1 : 1
Voltage
should be rectangular. If it includes ripple, the ripple factor should be
less than 5%.
However, please check with the actual circuit since the electrical
characteristics may vary. The rated coil voltage should be applied to
the coil and the set/reset pulse time of latching type relay differs for Time
each relays, please refer to the relay's individual specifications.
Coil connection Operate voltage change due to coil temperature rise
When connecting coils of polarized relays, please check coil polarity (Hot start)
(+,-) at the internal connection diagram (Schematic). If any wrong In DC relays, after continuous passage of current in the coil, if the
connection is made, it may cause unexpected malfunction, like current is turned OFF, then immediately turned ON again, due to the
abnormal heat, fire and so on, and circuit do not work. Avoid temperature rise in the coil, the pick-up voltage will become somewhat
impressing voltages to the set coil and reset coil at the same time. higher. Also, it will be the same as using it in a higher temperature
Maximum allowable voltage and temperature rise atmosphere. The resistance/temperature relationship for copper wire
Proper usage requires that the rated coil voltage be impressed on the is about 0.4% for 1°C, and with this ratio the coil resistance increases.
coil. Note, however, that if a voltage greater than or equal to the That is, in order to operate of the relay, it is necessary that the voltage
maximum continuous voltage is impressed on the coil, the coil may be higher than the pick-up voltage and the pick-up voltage rises in
burn or its layers short due to the temperature rise. Furthermore, do accordance with the increase in the resistance value. However, for
not exceed the usable ambient temperature range listed in the catalog. some polarized relays, this rate of change is considerably smaller.
Maximum allowable voltage for coil
In addition to being a requirement for relay operation stability, the
maximum continuous impressed coil voltage is an important constraint
for the prevention of such problems as thermal deterioration or
deformity of the insulation material, or the occurrence of fire hazards.
Ambient Environment
Dew condensation 2) If relays will not be used within 72 hours, please store relays in a
Condensation occurs when the ambient temperature drops suddenly humidity controlled desiccator or in an anti-humidity bag to which
from a high temperature and humidity, or the relay and microwave silica gel has been added.
device is suddenly transferred from a low ambient temperature to a *If the relay is to be soldered after it has been exposed to excessive
high temperature and humidity. Condensation causes the failures like humidity atmosphere, cracks and leaks can occur. Be sure to mount
insulation deterioration, wire disconnection and rust etc. the relay under the required mounting conditions
Panasonic Corporation does not guarantee the failures caused by 3) The following cautionary label is affixed to the anti-humidity pack.
condensation.
The heat conduction by the equipment may accelerate the cooling of
device itself, and the condensation may occur.
Please conduct product evaluations in the worst condition of the actual
usage. (Special attention should be paid when high temperature
heating parts are close to the device. Also please consider the
condensation may occur inside of the device.)
Icing
Condensation or other moisture may freeze on relays when the
temperature become lower than 0°C.This icing causes the sticking of
movable portion, the operation delay and the contact conduction failure
etc. Panasonic Corporation does not guarantee the failures caused by
the icing.
The heat conduction by the equipment may accelerate the cooling of
relay itself and the icing may occur. Please conduct product Silicon
evaluations in the worst condition of the actual usage. When a source of silicone substances (silicone rubber, silicone oil,
Low temperature and low humidity silicone coating materials and silicone filling materials etc.) is used
The plastic becomes brittle if the switch is exposed to a low around the relay, the silicone gas (low molecular siloxane etc.) may be
temperature, low humidity environment for long periods of time. produced.
High temperature and high humidity This silicone gas may penetrate into the inside of the relay. When the
Storage for extended periods of time (including transportation periods) relay is kept and used in this condition, silicone compound may adhere
at high temperature or high humidity levels or in atmospheres with to the relay contacts which may cause the contact failure. Do not use
organic gases or sulfide gases may cause a sulfide film or oxide film to any sources of silicone gas around the relay (Including plastic seal
form on the surfaces of the contacts and/or it may interfere with the types).
functions. Check out the atmosphere in which the units are to be NOx Generation
stored and transported. When relay is used in an atmosphere high in humidity to switch a load
Package which easily produces an arc, the NOx created by the arc and the
In terms of the packing format used, make every effort to keep the water absorbed from outside the relay combine to produce nitric acid.
effects of moisture, organic gases and sulfide gases to the absolute This corrodes the internal metal parts and adversely affects operation.
minimum. Avoid use at an ambient humidity of 85% RH or higher (at 20°C). If use
Storage requirements at high humidity is unavoidable, please contact our sales
Since the SMD type is sensitive to humidity it is packaged with tightly representative.
sealed anti-humidity packaging. However, when storing, please be
careful of the following.
1) Please use promptly once the anti-humidity pack is opened.(Signal
relay: within 72 hours, Max. 30°C/70% RH). If left with the pack
open, the relay will absorb moisture which will cause thermal stress
when reflow mounting and thus cause the case to expand. As a
result, the seal may break.
Others
Cleaning
1) Although the environmentally sealed type relay (plastic sealed type, 3) Cleaning with the boiling method is recommended (The temperature
etc.) can be cleaned, avoid immersing the relay into cold liquid (such of cleaning liquid should be 40°C or lower).
as cleaning solvent) immediately after soldering. Doing so may Avoid ultrasonic cleaning on relays. Use of ultrasonic cleaning may
deteriorate the sealing performance. cause breaks in the coil or slight sticking of the contacts due to the
2) Surface mount terminal type relay is sealed type and it can be ultrasonic energy.
cleaned by immersion. Use pure water or alcohol-based cleaning
solvent.