PLY900
PLY900
PLY900
PLY900 Indicator
1
PLY900 Indicator
Catalogue
Chapter 8 Attention---------------------------------------------------------------18
2
PLY900 Indicator
1、 Main functions
A combination of weighing, display, communication, printing and proportioning control.
With analog, digital double filtering function.
Automatic error diagnosis, easy to find and solve problems.
Provide complete material batch control.
Automatic/manual dosing.
The batching process can be suspended at any time.
With automatic zero tracking.
Can realize automatic reset to power on.
Automatic zeroing with ingredient start.
Automatic selection with 4 materials.
Feel free to modify and print the recipe.
With manual / automatic setting drop correction function.
With password permission setting function, easy to manage.
Zero setting range, zero tracking range, overload range.
2、 The main technical indicators
Basic parameters Description
Single row LED digital tube, LED light
Display
indication
Graduation value 1、2、5、10、20、50
Maximum display value 99999
Decimal point display 0、0.0、0.00
Weight unit kg
G.W 1600±300g
Performance
Accuracy ±0.01%FS
Maximum signal input range ±16mv
Sensor interface input impedance ≥20MΩ
3
PLY900 Indicator
4
PLY900 Indicator
Key Description
Key Description
Press the“menu”key in the weighing state 8seconds Enter the setting operation of the
configuration parameters.
After the data is input, press this button and the meter will store the entered value in
memory.
Return to the previous interface function, do not save any parameters when returning.
For example, the tare/zero button is valid only when the 0 button is pressed on the
main page (weighing page), and the zero tare/zero button is directly pressed to zero.
Must be on the main interface, the working state is 0, zero, and tare invalid.
Ten numeric keys for entering set values。Among them, the number keys 2 and 8
Number key
have a page turning function.
Note: Automatic mode: automatic batching and unloading during work; manual mode: manual discharge
is required during work, and discharge is completed and returned to the main interface; semi-automatic
5
PLY900 Indicator
mode: batching is completed, manual unloading is completed, and unloading is completed automatically.
Semi-manual state: the ingredients are completed, no unloading, return to the main interface.
1. Before connecting the sensor cable, please check whether the four corners of the sensor on the
weighing hopper are level, and the screw engagement part of the sensor should not exceed the upper
plane of the S-type sensor during installation.
2. Please connect the system three-phase incoming line and motor output line to the controller
reliably.
3. Connect the sensor cable and the hand-held box to the computer-side air connector.
4, the above process can be checked if it is correct, and the formula and calibration scale can be set.
4.1Calibration
Calibration;Press“Cal”more than 5 seconds
the interface.
Calibration step
3、 Enter the weight of the interface, in kg.
4、Place the weight on the weighing platform to keep the weighing
platform stable.
5、Click the “Enter” button on the panel to complete the calibration.
4.2 Parameter
Press “Parameter”key show the following table:
Parameter setting,long press the "Parameter" button for more than 5seconds,
No. Parameter Display Range default Remarks
0:Do not display the decimal
1 Decimal point 0-2 0 point
1:Display 1 decimal place
6
PLY900 Indicator
7
PLY900 Indicator
Drop 4 setting,
15 Drop 4 setting 0-99999KG 0
Input via numeric keypad
Drop automatically follow
16 Drop following ON/OFF ON the selection,
by“↑、↓”Selection parameter.
0:Manual mode, manual
unloading is required during
work, and unloading is
completed and returned to the
main interface.
1:Automatic mode,
automatic batching and
unloading during work;
17 Operating mode 0;1;2;3 2 2:Semi-automatic mode:
batching completed, manual
unloading, unloading
completed, automatic next
batching
3:Semi-manual state: the
ingredients are completed, no
unloading, return to the main
interface
Note:In the drop manual setting mode, the recipe and drop must be reset each time the decimal point
is changed. If you use the drop to automatically follow, you don't have to reset the drop.
8
PLY900 Indicator
9
PLY900 Indicator
A B C D E F G H I
Signed data-99999
Weight 01 03 00 01 00 02
000—99999000g
Decimal point 01 03 00 03 00 01 0-2
Indexing 01 03 00 04 00 01 1、2、5、10、20、50
Material interval
01 03 00 05 00 01 3-999s
time
Unloading waiting
01 03 00 06 00 01 1-999s
time
Cycle interval time 01 03 00 07 00 01 3-999s
Unloading 0:left unload
01 03 00 08 00 01
direction 1:right unload
Unloading
01 03 00 09 00 01 0-99
percentage
10
PLY900 Indicator
Unloading delay
01 03 00 0A 00 01 2-999s
time
0:4800
1:9600
Baud rate 01 03 00 0B 00 01
2:19200
3:115200
Zero range 01 03 00 0C 00 01 0-9999g
Sensor capacity 01 03 00 0D 00 02 0-99999kg
Drop1 01 03 00 0F 00 02 0-99999000g
Drop2 01 03 00 11 00 02 0-99999000g
Drop3 01 03 00 13 00 02 0-99999000g
Drop4 01 03 00 15 00 02 0-99999000g
Drop5 01 03 00 17 00 02 0-99999000g
Drop6 01 03 00 19 00 02 0-99999000g
Automatic 0:OFF
01 03 00 1B 00 01
adjustment of drop 1:ON
0(Single batch manual
unloading)
1(Automatic unloading
of circulating
ingredients)
Mode 01 03 00 1C 00 01
2(Manual unloading
of circulating
ingredients)
3(Single batch without
unloading)
Current formula 01 03 00 1D 00 01 1-4
Formula1 M1 01 03 00 1E 00 02 0-99999000g
Formula1 M2 01 03 00 20 00 02 0-99999000g
Formula1 M3 01 03 00 22 00 02 0-99999000g
Formula1 M4 01 03 00 24 00 02 0-99999000g
11
PLY900 Indicator
Formula1 M5 01 03 00 26 00 02 0-99999000g
Formula1 M6 01 03 00 28 00 02 0-99999000g
Formula2 M1 01 03 00 2A 00 02 0-99999000g
Formula2 M2 01 03 00 2C 00 02 0-99999000g
Formula2 M3 01 03 00 2E 00 02 0-99999000g
Formula2 M4 01 03 00 30 00 02 0-99999000g
Formula2 M5 01 03 00 32 00 02 0-99999000g
Formula2 M6 01 03 00 34 00 02 0-99999000g
Formula3 M1 01 03 00 36 00 02 0-99999000g
Formula3 M2 01 03 00 38 00 02 0-99999000g
Formula3 M3 01 03 00 3A 00 02 0-99999000g
Formula3 M4 01 03 00 3C 00 02 0-99999000g
Formula3 M5 01 03 00 3E 00 02 0-99999000g
Formula3 M6 01 03 00 40 00 02 0-99999000g
Formula4 M1 01 03 00 42 00 02 0-99999000g
Formula4 M2 01 03 00 44 00 02 0-99999000g
Formula4 M3 01 03 00 46 00 02 0-99999000g
Formula4 M4 01 03 00 48 00 02 0-99999000g
Formula4 M5 01 03 00 4A 00 02 0-99999000g
Formula4 M6 01 03 00 4C 00 02 0-99999000g
12
PLY900 Indicator
Example 1:
Modify the number of decimal places (display two decimal places):
Request:01 10 00 03 00 01 02 00 02 27 A2
Return:01 10 00 03 00 01 F1 C9
Example 2:
Modify the index (display index 5)
Request:01 10 00 04 00 01 02 00 05 67 D7
Return:01 10 00 04 00 01 40 08
Precautions:
1: The maximum setting range of ingredients and drop is related to the decimal point
When the decimal point is 0, the maximum setting range is 0-99999000g.
When the decimal point is 1, the maximum setting range is 0-9999000 grams.
When the decimal point is 2, the maximum setting range is 0-999000 g.
2: After calibrating the zero point, the calibration weight should be calibrated.
3: In the batching process, only start the ingredients, suspend the ingredients, return to the main interface,
the discharge command is valid, and other needs to be effective under the weighing interface.
Note:
A: Add B: function code
C: Start register address is high D: Start register address is low
E: High number of registers F: Low number of registers0
G: Number of bytes H: High register value
I: Low register value J: Write data description (decimal)
A B C D E F G H I J
Device address 01 10 00 00 00 01 02 0-255
Decimal point 01 10 00 03 00 01 02 0-2
13
PLY900 Indicator
1、2、5、10、20、
Indexing 01 10 00 04 00 01 02
50
Material interval
01 10 00 05 00 01 02 3-999s
time
Unloading
01 10 00 06 00 01 02 1-999s
waiting time
Cycle interval
01 10 00 07 00 01 02 3-999s
time
Unloading 0:left unload
01 10 00 08 00 01 02
direction 1:right unload
Unloading
01 10 00 09 00 01 02 0-99
percentage
Unloading delay
01 10 00 0A 00 01 02 2-999s
time
0:4800
1:9600
Baud rate 01 10 00 0B 00 01 02
2:19200
3:115200
Zero range 01 10 00 0C 00 01 02 0-9999g
Sensor capacity 01 10 00 0D 00 02 04 0-99999kg
Drop1 01 10 00 0F 00 02 04 0-99999000g
Drop2 01 10 00 11 00 02 04 0-99999000g
Drop3 01 10 00 13 00 02 04 0-99999000g
Drop4 01 10 00 15 00 02 04 0-99999000g
Drop5 01 10 00 17 00 02 04 0-99999000g
Drop6 01 10 00 19 00 02 04 0-99999000g
Automatic
0:OFF
adjustment of 01 10 00 1B 00 01 02
1:ON
drop
0:Single batch
Mode 01 10 00 1C 00 01 02
manual unloading
14
PLY900 Indicator
1:Automatic
unloading of
circulating
ingredients
2:Manual
unloading of
circulating
ingredients
3:Single batch
without
unloading
Current formula 01 10 00 1D 00 01 02 1-4
Formula1 M1 01 10 00 1E 00 02 04 0-99999000g
Formula1 M2 01 10 00 20 00 02 04 0-99999000g
Formula1 M3 01 10 00 22 00 02 04 0-99999000g
Formula1 M4 01 10 00 24 00 02 04 0-99999000g
Formula1 M5 01 10 00 26 00 02 04 0-99999000g
Formula1 M6 01 10 00 28 00 02 04 0-99999000g
Formula2 M1 01 10 00 2A 00 02 04 0-99999000g
Formula2 M2 01 10 00 2C 00 02 04 0-99999000g
Formula2 M3 01 10 00 2E 00 02 04 0-99999000g
Formula2 M4 01 10 00 30 00 02 04 0-99999000g
Formula2 M5 01 10 00 32 00 02 04 0-99999000g
Formula2 M6 01 10 00 34 00 02 04 0-99999000g
Formula3 M1 01 10 00 36 00 02 04 0-99999000g
Formula3 M2 01 10 00 38 00 02 04 0-99999000g
Formula3 M3 01 10 00 3A 00 02 04 0-99999000g
Formula3 M4 01 10 00 3C 00 02 04 0-99999000g
Formula3 M5 01 10 00 3E 00 02 04 0-99999000g
Formula3 M6 01 10 00 40 00 02 04 0-99999000g
Formula4 M1 01 10 00 42 00 02 04 0-99999000g
15
PLY900 Indicator
Formula4 M2 01 10 00 44 00 02 04 0-99999000g
Formula4 M3 01 10 00 46 00 02 04 0-99999000g
Formula4 M4 01 10 00 48 00 02 04 0-99999000g
Formula4 M5 01 10 00 4A 00 02 04 0-99999000g
Formula4 M6 01 10 00 4C 00 02 04 0-99999000g
Tare(Clear) 01 10 00 4E 00 01 02 00 AA Fixed value
Restore factory se
01 10 00 4F 00 01 02 00 FF Fixed value
ttings
Cal(cal Zero
01 10 00 50 00 01 02 FF FF Fixed value
point)
Cal(cal weight) 01 10 00 50 00 01 02 0-9999kg
Unloading 01 10 00 51 00 01 02 DD DD Fixed value
Starting
01 10 00 52 00 01 02 AA AA Fixed value
ingredients
Pause ingredients 01 10 00 53 00 01 02 BB BB Fixed value
Return to main
01 10 00 54 00 01 02 CC CC Fixed value
interface
6.1、Error indication
Display content Meaning Solution
Keep the scale stable and re-calibrate
Calibration failed
the scale
More than maximum display Decrease the number of decimal
digits places
16
PLY900 Indicator
Ingredients 1 error
An ingredient error indicates that the
Ingredients 2 error weight of the actual ingredient is
Note:During the operation of all the buttons, if the operation is wrong, the error LED on the display
panel will be illuminated. If the password is entered incorrectly, press any key and then re-enter. If it is
the start of the ingredient, the error is because the ingredient value is not set.
6.2、Troubleshooting
(1)Failure analysis that cannot be returned to zero after weighing
In the case of ensuring that the sensor output is normal (the scale body is stable), generally the zero
point range setting is too small, and the zero point range should be set larger.
(2)Inaccurate fault analysis
Observe whether the internal code value is stable, whether there is friction in all parts of the sensor,
whether the stabilized power supply is stable, whether the operational amplifier circuit is normal, and
whether the weight of the four-legged weighing pan is averaged using the weight. Further instrumental
analysis or weight correction according to the instructions.
(3)Unable to boot
First determine the problem of non-fuse, power switch, power line and voltage switch, check the
transformer for AC voltage input and AC output. Secondly, check whether the rectifier circuit, the
voltage regulator circuit and the display driver circuit are abnormal. If there is no problem, check
whether the processor and the auxiliary circuit are burnt out.
(4)Show garbled
Remove the original display circuit and change to a normal display circuit to see if it is normal. If
the display is normal, the display circuit has a problem. If it is not normal, check the driver circuit for
faults. Finally, check if the processor shows that the output pin is in a reasonable output range.
(5)Can't be called full
Similar to the situation where it is impossible to return to zero, most of them may be changed due to
17
PLY900 Indicator
the small signal input range or the range setting is not set correctly. According to the method that cannot
be returned to zero, if the problem cannot be found, first check whether the power supply, A/D circuit is
normal, the range setting is normal, and then detect the sensor output.
Chapter 8 Attention
(1) Do not remove the connector on the rear panel of the instrument or replace the sensor when power is
on.
(2) Do not use organic solvents such as hydrocarbons, alcohols, ketones or strong acid or strong alkali
solutions to clean the instrument, so as not to damage the casing, panel and internal components of the
instrument.
18
PLY900 Indicator
※ This equipment cannot be cleaned with organic solvents such as hydrocarbons, alcohols, ketones or
strong acid or alkali solutions to avoid damage to the casing, panels and internal components of the
equipment.
※ This equipment will not accept any repairs or modifications made by you. If
the equipment malfunctions, please follow this manual for troubleshooting or
contact us, otherwise you will lose the right to after-sales service.
※ Do not install in dusty, multi-metal powder.
※ Non-corrosive, explosive gas at the installation site.
※ Installed in a place where there is no direct sunlight or shelter from the rain.