P3-08DA-2 Analog Output: Removable Terminal Block Specifications

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

To minimize the risk of potential safety problems, you should follow

all applicable local and national codes that regulate the installation
and operation of your equipment. These codes vary from area to
area and it is your responsibility to determine which codes should
be followed, and to verify that the equipment, installation, and oper-
ation are in compliance with the latest revision of these codes.
Equipment damage or serious injury to personnel can result P3-08DA-2 Analog Output
from the failure to follow all applicable codes and standards. We The P3-08DA-2 Voltage Analog Output Module
do not guarantee the products described in this publication are provides 8 channels of ±10 VDC outputs for
suitable for your particular application, nor do we assume any use with the Productivity3000 Programmable
responsibility for your product design, installation, or operation. Automation Controller.
If you have any questions concerning the installation or opera-
tion of this equipment, or if you need additional information, please Safety Information. . . . . . . . . . . . . . 1
call Technical Support at 770-844-4200. Removable Terminal Block
This publication is based on information that was available at Specifications. . . . . . . . . . . . . . . 1
General Specifications . . . . . . . . . . 2
the time it was printed. At AutomationDirect.com® we constantly Output Specifications . . . . . . . . . . . 2
strive to improve our products and services, so we reserve the right Schematic and Wiring Diagram. . . . 3
to make changes to the products and/or publications at any time Module Installation Procedure. . . . . 4
without notice and without any obligation. This publication may also Terminal Block Removal. . . . . . . . . 4
discuss features that may not be available in certain revisions of Hot Swap Information. . . . . . . . . . . 4
Wiring Options. . . . . . . . . . . . . . . . . 5
the product. Module Configuration . . . . . . . . . . . 5
Linear Scaling. . . . . . . . . . . . . . . . . 6
Non-Linear Scaling. . . . . . . . . . . . . 6
LCD Panel Display Menus . . . . . . . 7

Removable Terminal Block Specifications


Number of Positions 20 screw terminals
Wire Range 22-14 AWG (0.324 to 2.08 sq. mm)
solid / stranded conductor
3/64 in. (1.2 mm) insulation maximum
“USE COPPER CONDUCTORS, 60°C” or equivalent*.
Screw Driver Width 1/4 inch (6.5 mm) maximum
Screw Size M3 size
Screw Torque Field terminals – 7 - 9 in./lb (.0.882 - 1.02 Nm)
Self-jacking screws – 2.7 - 3.6 in./lb (0.3 - 0.4 Nm). Terminal Block sold separately, Terminal Block Cover included
Do not overtighten screws when installing terminal block. (see wiring options on page 5).
Warranty: Thirty-day money-back guarantee. Two-year limited replacement.
(See www.automationdirect.com/P3000 for details).

Sales 800-633-0405 www.automationdirect.com/P3000 1


General Specifications Output Specifications
Operating Temperature 0° to 60°C (32° to 140°F), Output Channels 8
Storage Temperature -20° to 70°C (-4° to 158°F) Module Signal Output Range ±10VDC
Humidity 5 to 95% (non-condensing) Output Signal Resolution 16-bit
Environmental Air No corrosive gases permitted Resolution Value of LSB ±10V = 305µv/count
Vibration IEC60068-2-6 (Test Fc) (least significant bit) 1 LSB = 1 count
Shock IEC60068-2-27 (Test Ea)
Data Range -32768 to +32767 counts
Field to Logic Side Isolation1800 VAC applied for 1 second
Output Type (sourcing/sinking) Voltage: 10mA max
Insulation Resistance >10MV @ 500 VDC
Output Value in Fault Mode 0V
Heat Dissipation 3.3 W
Load Impedance M 1000 V
Enclosure Type Open Equipment
Maximum Capacitive Load .01µF maximum
Agency Approvals UL508 file E157382, Canada & USA
Allowed Load Type Grounded
UL1604 file E200031, Canada & USA
Maximum Inaccuracy 0.1% of range
CE (EN61131-2*)
(including temperature drift)
This equipment is suitable for use in Class 1,
Division 2, Groups A, B, C and D or non-hazardous Maximum Full Scale Calibration ±.025% of range maximum
locations only. Error (not including offset error)
Maximum Offset Calibration Error ±.025% of range maximum
Module Keying to Backplane Electronic
Accuracy vs. Temperature ±25 ppm/ °C maximum full scale calibration
Module Location Any I/O slot in any local, expansion, or remote
change (± .0025% of range / °C)
base in a Productivity3000 System.
Max Crosstalk -96 dB, 1 LSB
Field Wiring Removable terminal block (not included). Use
ZIPLink Wiring System or optional terminal block. Linearity Error (End to End) ±16 LSB maximum (±0.025% of full scale)
See “Wiring Options” on page 5. Monotonic with no missing codes
Output Stability and Repeatability ±10 LSB after 10 min. warm-up (typical)
EU Directive See the “EU Directive” topic in the
Productivity3000 Help File. Information can also be Output Ripple .05% of full-scale
obtained at: www.automationdirect.com/P3000 Output Settling Time 0.3 ms max, 5 µs min (full scale change)
Terminal Type (not included) 20-position removable terminal block All Channel Update Rate (typical) 0.6ms
Weight 105g (3.73 oz) Maximum Continuous Overload Outputs current limited to 40mA typical
Continuous overloads on multiple outputs
*Meets EMC and Safety requirements. See the D.O.C. for details. can damage the module.
Type of Output Protection 0.1µf Transient Suppressor
Output Signal (power-up, -down) 0V
External DC Power Required 24VDC (-20% / + 25%), 120mA
WARNING: Explosion hazard – Substitution of components may impair suitability
for Class I, Division 2.
AVERTISSEMENT: Risque d’explosion : la substitution de composants peut com-
promettre la convenance pour la Classe I, Zone 2 ou pour la Classe I, Division 2.

2 www.automationdirect.com/P3000 Tech Support 770-844-4200


Wiring Diagram Schematic

INTERNAL
Voltage Output Circuits MODULE CIRCUITRY

V+
V1+ voltage sink/source
0 - 10 CH1 DAC
VDC Load COM V2+ voltage sink/source
CH2 DAC
V3+ voltage sink/source
CH3 DAC
V4+ voltage sink/source
AC or DC CH4 DAC
Power Supply V5+ voltage sink/source
CH5 DAC
V6+ voltage sink/source
CH6 DAC
V7+ voltage sink/source
CH7 DAC
V8+ voltage sink/source
V+ CH8 DAC
COM
±10 VDC
Load COM COM
COM
COM
Load
Power Supply

V+
-10 - 0
VDC Load COM

24VDC-
- +
24VDC+ ISOLATED ANALOG
Load
Power Supply CIRCUIT POWER
24 VDC User
Supplied Power

ISOLATED ANALOG
CIRCUIT COMMON

Sales 800-633-0405 www.automationdirect.com/P3000 3


Module Installation Procedure Terminal Block Removal 3. Grip opened door along
WARNING: Do not apply field power until the following edge to avoid flexing door
Align 2. Loosen self- and pull terminal block
here steps are completed. See hot-swapping procedure for jacking screws
exceptions. from module.
to disengage
AVERTISSEMENT: Ne pas appliquer la puissance de terminal block.
champ avant l’exécution des étapes qui suivent. Consultez
la procédure de remplacement à chaud pour les exceptions.

Step One: Align circuit card with slot and 1. Pull hinged
press firmly to seat module into connector. door open

Align
Step Two: Pull top and bottom locking here.
here tabs toward module face. Click indicates lock
is engaged.

NOTE: Do not grip


door in middle.

Step Three: Attach field wiring using


optional terminal block or ZIPLink wiring
system and install cover.
To install or remove terminal
block cover, press middle to flex
cover.

Important Hot-Swap Information


The Productivity3000 PAC supports hot-swap!
Individual modules, expansion bases, and entire
remote base groups can be taken offline, removed, and
replaced while the rest of the PAC system continues
WARNING: Explosion hazard – Do not connect or disconnect connectors or controlling your process. Before attempting to use the
operate switches while circuit is live unless the area is known to be non-hazardous. hot-swap feature, be sure to read the hot-swap topic in
Do not hot-swap modules unless the area is known to be non-hazardous.
the programming software’s help file or our online docu-
AVERTISSEMENT: Risque d’explosion : ne pas connecter ou déconnecter les connec- mentation at AutomationDirect.com for details on how to
teurs ni actionner les commutateurs alors que le circuit est sous tension, à moins que la
zone ne soit reconnue non dangereuse. Ne pas remplacer à chaud les modules à moins
plan your installation for use of this powerful feature.
que la zone ne soit reconnue non dangereuse.

4 www.automationdirect.com/P3000 Tech Support 770-844-4200


Wiring Options Module Configuration
1
ZIPLink Connection System
Cable + ZIPLink Module = Complete System Using the Hardware Configuration tool in
the Productivity Suite programming software,
ZIPLink pre-wired
terminal block cables drag and drop the P3-08DA-2 module into
the base configuration.
0.5m (1.6FT) cable ZL-P3-CBL20-L Select Automatic Module Verification or No
1.0m (3.3FT) cable ZL-P3-CBL20-1L Verification and Enable Hot Swap and Stop
2.0m (6.6FT) cable ZL-P3-CBL20-2L Mode Values. If desired, assign a User
Tagname to each output point (channel)
selected and to each Status Bit Item.

ZIPLink Modules

Feed through ZL-RTB20

2
Terminal Block with pigtail cable

0.5m (1.6FT) cable ZL-P3-CBL20-P


1.0m (3.3FT) cable ZL-P3-CBL20-1P
2.0m (6.6FT) cable ZL-P3-CBL20-2P

3
Terminal Block only

P3-RTB
(Quantity 1)

Sales 800-633-0405 www.automationdirect.com/P3000 5


Linear Scaling Non-Linear Scaling

The Scale (Linear) function can be used to: The Scale (Non-Linear) function can be used for Non-Linear
applications.
• Convert an application specific range to a range which is native to the
analog output module.
• Make other linear conversions in ranges appropriate to the application.

Level Transmitter Tank Level

Tank Level Control Valve


0 0
1 .5
220 2 1
3 1.55
12500 4 2.25
5 3
-32768 6 4.55
6.5 6.75
Select the Input and Output tags appropriate
32767 7 7
for the application. Convert raw input signals
0 0
to engineering units for use in the program, or
0 0
convert engineering units to output signals for
0 0
control purposes Select the
0 0 minimum and maximum
max 0 values of0 the raw input signal. These
0 values will
0 relate to the minimum
0 and maximum
0 scaled values.
7
6
5
min 4
3
min max 2
1
0
1 2 3 4 5 6 7

6 www.automationdirect.com/P3000 Tech Support 770-844-4200


LCD Panel Display

Power On Hold SEL button down to cycle through primary screens. Release button to select screen.
 Appears    
initially

     
     
   
These screens will
then auto cycle

 This screen will


 auto cycle with     
 status Momentarily Press   
 information
SEL button to   
  
toggle through

secondary displays
 
  
 
  

  
  

Error Messages:    


An existing error will    
be inserted into the    
cycling Status Info   
screen.

Sales 800-633-0405 www.automationdirect.com/P3000 7


Document Name Edition/Revision Date
P3-08DA-2-M 1st Ed. Rev. B 12/06/2017
Copyright 2017, AutomationDirect.com Incorporated/All Rights Reserved Worldwide

8 www.automationdirect.com/P3000 Tech Support 770-844-4200