Silo Lifting Lug Weld Check (Shell To Lug) Jamtkraft Biofuel Vertical Weld

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

ISGEC SFW BOILERS PVT. LTD.

Project JAMTKRAFT

Part Fuel Silo Lifting Lug DATE

Weld Check For Biofuel Silo Lifting Lug Arrangement 21-11-2023


𝐹𝑁
Factored Dead Load of Silo FTotal 34921.935 kg
342584.1824 N
𝐹
No. of Lifting lugs 4
No. of Lifting Lugs Considered 2

Lifting Load Considered F 171292.0912


Width of Lug = Length of Weld Lv 90 mm 𝛼
𝐹𝑣
Size of weld Provided a 4 mm
Angle of Lifting α 60 Deg

Shearing Force Fv 0.00 N


Normal Force FN 148343.30 N

Yeild Strength of Plate fy 355 MPa


𝐿𝑣
Ultimate Strength of Plate fu 490 MPa
Correlation Factor 0.9
Partial Safety Factor 1.25

DIRECTIONAL METHOD OF WELD CALCULATION:

Condition 1:

0.00

206.03

356.86

435.56

Utilization Ratio 0.82

Condition 2:

206.03

352.8

Utilization Ratio 0.58