Aco Rainwater Outlets Brochure

Download as pdf or txt
Download as pdf or txt
You are on page 1of 40

Uniclass April 2015

L73144
CI/Sf6 S2
(52.5) ACO Building Drainage
Dr ai nage Syste ms

Product catalogue and specifiers design guide


ACO Building Drainage High Performance Rainwater
Outlets for Flat Roofs, Car Park Gullies and Other Areas
ACO Building Drainage

ACO Building Drainage

Our built environment is becoming ever more


complex. Applications are becoming more
sophisticated and the increasing pressure of
regulations and standards makes achieving
design, performance and financial goals ever ACO Building Drainage • A complete pricing service to stockists,
tougher. Enquiries Team: contractors and clients.
Tel: +44(0)1462 810421
Our mission: to eliminate design risk, to Fax: +44(0)1462 851490
reduce installed and life cost and to deliver Email: [email protected]
exceptional finish and performance in every
product application.
ACO Building Drainage • Product availability, delivery lead times, and
Our global resources and manufacturing Customer Services Team: all other queries including collections,
capacity make it possible for us to deliver best Tel: +44(0)1462 810411 returns and product / service issues.
value, both with our standard products and Fax: +44(0)1462 851490
with our bespoke designs. Confidence is Email: [email protected]
further assured with quality systems that are
in accordance with ISO 9001-2008.
ACO Building Drainage • Technical and installation advice.
Design Services Team: • Detailed design and ‘Value Engineering’ advice.
ACO Building Drainage is a division of ACO
Tel: +44(0)1462 810431 • Hydraulic calculations and AutoCAD drawings.
Technologies plc and part of the worldwide
Fax: +44(0)1462 851490 • Advice on the suitability of ACO equivalent
ACO Group. The Group has sales in excess of
Email: [email protected] products.
£600 million worldwide with production
facilities in the UK, Germany, France,
Switzerland, Denmark, Spain, Poland, Czech ACO Building Drainage • For all product brochures, imagery or
Republic, Australia and the USA. In total Marketing and Media Support mechandising material requests.
more than 3900 people are employed in over Tel: +44(0)1462 810400
40 countries throughout the world. Fax: +44(0)1462 851490
Email: [email protected]

collect: clean: hold: release:


 Stainless Steel and  Grease Management  Anti-flood Backflow  Lifting Stations*
Galvanised Steel Channels Systems Protection Systems

 Stainless Steel Gullies

 Pipe Systems

 Roof / Balcony Drainage

 Wetroom & Shower Drainage

*Available in 2015

Office address and contact details: For quick access to


our website, scan:
ACO Building Drainage Tel: +44(0)1462 810400
ACO Business Centre Fax: +44(0)1462 851490
Caxton Road Email: [email protected]
Bedford
Company Registration No: 1854115
Bedfordshire
VAT No: GB 650 7977 05
MK41 0LF

www.acobd.co.uk
ACO High Performance Rainwater Outlets

Contents

System Overview and Design Consederations

Flat Roofs and Typical Applications 4

Materials 4

Standard References 4

Hydraulic Design and Geographical Location 5

Flow Rate Calculation 5

Effective Catchment Area of Roofs 6

Technical Data - HP Rainwater Outlets

ACO HP Product Range Overview 8

ACO HP Vertical Spigot Outlets 9

ACO HP Vertical Screw Outlets 11

ACO HP 45° Spigot Outlets 13

ACO HP 45° Screw Outlets 15

ACO HP 90° Spigot Outlets 17

ACO HP 90° Screw Outlets 19

ACO HP Balcony Spigot Outlets 21

ACO HP Two-Way Screw Outlets 22

ACO HP Gully Spigot Outlets 23

ACO HP Gully Refurbishment Outlets 24

ACO HP Overflow Outlet Modules 25

ACO Raising Rings 26

ACO ABS Threaded Adaptors 27

ACO Discharge Spouts 27

ACO Terrace Grate 28

ACO Deck Supports 28

Technical Data - Car Park Gullies


3

ACO Car Park Gullies - Product Range Overview 29

ACO Car Park Gullies 30

ACO Car Park Gullies - Accessories 32

Installation Recommendations - HP Rainwater Outlets

Typical Flat Roof Construction Details 33

Typical Installation Guide and Construction Detail 34

Refurbishment Outlet Installation Guidelines 37

Associated ACO Building Drainage Product Ranges

Associated ACO Building Drainage Product Ranges 38


ACO High Performance Rainwater Outlets

System Overview

Flat Roofs Materials Typical Applications

The past few years have seen major advances All ACO Building Drainage High Performance ACO Building Drainage High Performance
and improvements in the materials used in Rainwater Outlets are manufactured from die- Rainwater Outlets - page 8
modern roofing technology. A specifier now cast marine-grade LM6 aluminium silicon  Flat roofs
has renewed confidence to take full advantage alloy. This grade of aluminium alloy is highly
 Low-pitched roofs
of the benefits flat and low-pitched roof corrosion resistant, weather-proof and
designs can offer. resistant to ultra-violet radiation.  Balconies

 Roof terraces
Flat roofs provide opportunities for planning All cast components are polyester powder
and design flexibility, for example; terracing, coated. For additional protection, this tough ACO Building Drainage Car Park Gullies
roof-top gardens, patios, car parks, delivery and resilient powder coated finish prevents - page 29
areas, building services and ventilation natural galvanic corrosion in applications
 Multi storey car parks
equipment and the ability to add additional where dissimilar metals are dressed into the
 Parking decks
storeys at a later date. outlets. 304 stainless steel fixings are used to
ensure long-service durability and reliability.
Large area roofs or irregular shaped buildings Standard References:
can be completed more quickly, easily and All ACO Building Drainage Rainwater Outlets
Design requirements and flow rate
cost effectively than a pitched roof. are available in leaded gun metal to BS EN
performance refer to EN 1253:2015 Gullies
1982:2008 to special order for lead or
for Buildings – Part 2: Roof drains and floor
Flat roofs also allow easy access to natural copper-clad roofs or connection to copper
gullies without trap.
light and because of the simple construction, pipework.
internal partitioning is easy and particularly
Roof drainage layout and hydraulic
advantageous for commercial or industrial ACO Building Drainage Car Park Gullies are
calculations refer to BS EN 12056-3:2000
buildings. manufactured from grey cast iron for robust
Gravity drainage systems inside buildings –
and durable applications to accommodate
Part 3: Roof drainage, layout and calculation.
heavy and frequent vehicle loads.

High Performance (HP) outlets for a wide range of applications


Design Considerations

Hydraulic Design Geographical Location Flow Rate Calculation

The following notes are intended as a guide to Rainfall intensity has a direct impact on the The runoff, or flow rate Q, from roofs, paved
the specifier who is designing a rainwater performance requirements of any rainwater areas as surfaces is calculated as follows and
drainage system for a roof. It is recommended drainage system. For roofs and paved areas, assumes that all surfaces are impermeable:
to refer to BS EN 12056-3:2000 Gravity it is normally impracticable to guard against
drainage systems inside buildings – Part 3: very infrequent, extremely heavy rainfall AxI
Roof drainage, layout and calculation for a situations so the designer should aim to strike Q = --------- litres/second
comprehensive design guide. a balance between the cost of the drainage 3600
system, the risk category of the building and
For any rainwater drainage system to work the frequency and subsequent consequences where
effectively and reliably, it is recommended the of flooding in the advent of particularly high
specifier considers the following: rainfall events. Q = Volumetric flow rate (l/s)

 Geographical location of the building The United Kingdom experiences complex and A = Effective catchment area (m²)
varied rainfall patterns, for example; although
 Rainfall intensity
the upland areas of northern and western I = Rainfall intensity (75mm/hr)
 Storm duration and return period
parts of the British Isles experience higher
 Effective catchment area of roof
average annual rainfall than the lowland areas
 Risk category of the building however, the lowland areas experience more
 Hydraulic capacity of the drainage frequent and more intense short duration Alternatively,
system(s) employed rainfall than the upland areas. BS EN 12056-
3:2000 provides further information and Q = r x A litres/second
guidance on this topic.
where
Practical Design Tips
A rainfall intensity of 75mm/hr
When designing an engineered rainwater (0.02083 l/s/m²) is used throughout Q = Volumetric flow rate (l/s)
scheme, the following design hints are this design catalogue.
suggested: r = Rainfall intensity (l/s/m²)
 Do not design for the maximum outlet
hydraulic capacity. Allow a 10% factor of A = Effective catchment area (m²)
safety margin for intense storms and
leaf/debris blockage. For reference, a rainfall intensity of 75mm/hr
 Always allow for a back-up outlet, even = 0.02083 l/s/m²
though only one outlet may be required.
5
 Rainwater outlets should be inspected and
cleaned at least every 6 months to ensure Note. Using either of the formulae above to

reliable and continuous operation. calculate runoff (Q), for a given rainfall
intensity and by knowing the flow rate
performance of an individual rainwater outlet,
the effective roof area drained can be
calculated.

Flow rate performance and effective area


drained are provided for each outlet contained
in this catalogue.
ACO High Performance Rainwater Outlets

Effective Catchment Area of Roofs

Roof Type Diagram Catchment Area Calculation

Pitched roofs Figure 1.

Taking into account the effects of wind Plan Catchment Area


LR
driven rain, the effective area of a freely
A = (BR x LR) + HR/2 x LR) (m²)
exposed pitched roof draining to an eaves
= LR(BR x HR/2) (m²)
gutter or parapet wall gutter is equal to the
plan area of the roof plus half its maximum
elevation area.
HR All dimensions in linear metres.

BR

Catchment area A

Flat roofs & paved areas Figure 2.


Catchment Area
LR
Monopitch Flat Roof B = LR x TR (m²)
For a monopitch flat roof or paved area
with a freely exposed horizontal surface,
the effective catchment area is equal to the
plan area of the area to be drained as
TR
shown below:
Catchment area B
6

Dual Pitch Flat Roof Figure 3.


For a dual pitch flat roof, split the
For a dual pitch flat roof, split the roof into roof into discrete areas to isolate the
Catchment area C
discrete areas to isolate the catchment catchment areas as shown:
areas as shown: LR
Catchment Area
C= LR x TR2 (m²)

Catchment Area
TR2
D= LR x TR1 (m²)
TR1

Catchment area D All dimensions in linear metres.


Design Considerations

Roof Type Diagram Catchment Area Calculation

Adjacent vertical surfaces

Flat roofs or paved areas that are adjacent


to vertical walls and/or glazed surfaces will Figure 4.
be subject to an increased hydraulic load
due to the effects of wind driven rain Catchment area E
against these vertical surfaces and LR
subsequently running off onto the roof.
H

Monopitch Flat Roof with


Catchment Area B = LR x TR (m²)
One Adjacent Vertical Wall
Catchment Area E = LR x H/2 (m²)
For a flat roof exposed to a single wall,
assume the effective catchment areas to be
Total Catchment Area
half the exposed vertical area of the wall
= (LR x TR) + (LR x H/2) (m²)
and is shown as follows:

TR All dimensions in linear metres.

Catchment area B

Monopitch Flat Roof with Two Adjacent Figure 5.


Catchment Area B = LR x TR (m²)
Vertical Walls LR
Catchment Area E = LR x H/2 (m²)
Catchment area F Catchment area E
Similarly, for a flat roof exposed to two or
Catchment Area F = TR x h/2 (m²)
more vertical walls forming an angle or bay,
Total Catchment Area = (LR x TR) + ½√
the assumed resulting wind direction
requires that the combined areas of the (E² + F² - 2F x Cos Ɵ) (m²)

walls should be considered together as


follows: All dimensions in linear metres;
h
H angles in degrees.
7
TR
Catchment area B
ACO High Performance Rainwater Outlets

Product range overview

ACO HP vertical spigot outlet ACO HP two-way screw outlet ACO HP 45° & 90° outlets

General purpose rainwater outlets suitable for The two-way outlet is designed to be used at These angled problem solving outlets are
convenient direct connection to PVC-U ‘O’-ring the junction of roofs and parapet walls, or particularly relevant to suit more complex pipe
socket pipe to BS 4514:2001 or to cast iron wherever horizontal and vertical surfaces meet. run detail. Pipework connections as spigot or
pipework to BS 416:1990 or BS EN 877: This flexible design of outlet allows either a screwed outlets.
1999. Other connections can be made using horizontal or vertical outflow take-off. Pipework
an appropriate flexible coupling or heat shrink connections as for vertical screw details.
sleeving.

Vertical spigot outlets are available with either


domed or flat gratings. Flat gratings are used
where either vehicles or pedestrian traffic is
likely.

ACO HP vertical screw outlet ACO HP balcony spigot outlet ACO HP Refurbishment outlet

8
Screwed outlets are recommended where The balcony outlet provides discrete safe When an existing flat roof is being upgraded,
connection to the outlet occurs within the drainage for balconies and walkways. Supplied the refurbishment outlet is designed to fit
thickness of the slab and threaded connections complete with a ‘D’-shaped flat grating, the inside the existing outlet and pipework with
will form a completely gas-tight seal. outlet can be installed directly against a wall. minimal disruption without the need to remove
The grating is supplied with suitable apertures the original unit or pipework.
to accommodate 50mm, 75mm or 100mm
Vertical screw outlets have a female parallel
nominal bore rainwater downpipes, easily cut
thread to BS 21:1985 for connecting directly Outlets are supplied with a flexible finned pipe
on site to suit the application.
to pipes conforming to BS EN 10226:2005. seal ensuring a watertight connection to
This ensures a completely watertight seal when existing pipework. The ease of use and
screwed home into the outlet body. minimal disruption to the existing rainwater
system makes this an extremely cost effective
solution when upgrading flat roofs.
A range of ABS threaded adaptors are available
from ACO Building Drainage to allow
connection to PVC-U, socketless cast iron and
aluminium rainwater pipes.

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Technical Data

ACO HP Vertical Spigot Outlet – Dome Grate

B
Membrane

D
C
E

Nominal Bore Pipe OD Area Drained‡ Flow rate† Weight


Part No Product Ref
Pipe Size (mm) (mm) (m²) (l/s) (kg)

105900 50HP-D 50 60 82 1.7 2.50


105901 75HP-D 75 83 240 5.0 2.40
105902 100HP-D 100 110 514 10.7 3.10
105903 150HP-D 150 160 725 15.1 3.60

† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).

Product Dimensions (mm)


Part No Product Ref Nominal bore pipe size
A B C D E

105900 50HP‐D 50 300 260 105 200 60


105901 75HP‐D 75 300 260 110 200 83
105902 100HP‐D 100 380 310 130 240 110
105903 150HP‐D 150 380 310 160 240 160

Pipework connections Specification clause


All components used within the scope of this
9
Vertical spigot outlets may be directly The rainwater outlets 50HP-D/75HP-
connected to the following: D/100HP-D/150HP-D* are to be ACO system are shown on Drawing No. * and all

 Cast iron pipework to BS 416:1990 or Building Drainage HP vertical spigot outlets work shall be carried out strictly in

BS EN 877 :1999. with locked dome grating supplied by ACO accordance with the manufacturer’s
Building Drainage (a division of ACO instructions and the installation details are
 PVC-U ‘O’-ring socketed pipe to
Technologies plc), ACO Business Centre, set out on Drawing No. *.
BS 4514:2001 (for 75HP-D, 100HP-D
Caxton Road, Bedford MK41 0LF.
and 150HP-D outlets only).
 Connection to 50HP-D outlets via pipe * please delete or complete as appropriate.

couplings or heat shrink socket. All components to be manufactured from


grade LM6 aluminium silicon alloy to
BS EN 1706:2010.

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO High Performance Rainwater Outlets

ACO HP Vertical Spigot Outlet – Flat Grate

A
B
Membrane

D
C
E

Nominal Bore Pipe OD Area Drained‡ Flow Rate† Weight


Part No Product Ref
Pipe Size (mm) (mm) (m²) (l/s) (kg)

105904 50HP-F 50 60 82 1.7 2.80


105905 75HP-F 75 83 240 5.0 2.70
105906 100HP-F 100 110 514 10.7 3.80
105907 150HP-F 150 160 787 16.4 4.20

† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).

Product Dimensions (mm)


Part No Product Ref Nominal bore pipe size
A B C D E

105904 50HP‐F 50 300 260 105 200 60


105905 75HP‐F 75 300 260 110 200 83
105906 100HP‐F 100 380 310 130 240 110
105907 150HP‐F 150 380 310 160 240 160

Pipework connections Specification clause


10 All components used within the scope of this
Vertical spigot outlets may be directly The rainwater outlets 50HP-F/75HP-
connected to the following: F/100HP-F/150HP-F* are to be ACO Building system are shown on Drawing No. * and all

 Cast iron pipework to BS 416:1990 or Drainage HP vertical spigot outlets with work shall be carried out strictly in

BS EN 877 :1999. locked flat grating supplied by ACO Building accordance with the manufacturer’s
Drainage (a division of ACO Technologies plc), instructions and the installation details are set
 PVC-U ‘O’-ring socketed pipe to
ACO Business Centre, Caxton Road, Bedford out on Drawing No. *.
BS 4514:2001 (for 75HP-F, 100HP-F
MK41 0LF.
and 150HP-F outlets only).
 Connection to 50HP-F outlets via pipe * please delete or complete as appropriate.

couplings or heat shrink socket. All components to be manufactured from


grade LM6 aluminium silicon alloy to
BS EN 1706:2010.

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Technical Data

ACO HP Vertical Screw Outlet – Dome Grate

B
Membrane

D
C
E

Nominal Bore Area Drained‡ Flow Rate† Weight


Part No Product Ref
Pipe Size (mm) (m²) (l/s) (kg)

105908 50HP-TD 50 82 1.7 2.20


105909 75HP-TD 75 240 5.0 2.30
105910 100HP-TD 100 514 10.7 3.00
105911 150HP-TD 150 730 15.2 3.10

† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).

Product Dimensions (mm)


Part No Product Ref Nominal bore pipe size
A B C D E

105908 50HP‐TD 50 300 260 45 130 2" BSP


105909 75HP‐TD 75 300 260 45 130 3" BSP
105910 100HP‐TD 100 380 310 45 130 4" BSP
105911 150HP‐TD 150 380 310 45 130 6" BSP

See Page 27 for ABS threaded adaptors

11

Pipework connections Specification clause


ACO threaded outlets are supplied with a The rainwater outlets 50HP-TD/75HP- All components used within the scope of this
parallel female screw thread to BS 21: 1985 TD/100HP-TD/150HP-TD* are to be ACO system are shown on Drawing No. * and all
for connection to tube conforming to BS EN Building Drainage HP vertical threaded outlets work shall be carried out strictly in
10255:2004 with male taper thread to with locked dome grating supplied by ACO accordance with the manufacturer’s
BS 21:1985. This ensures a completely Building Drainage (a division of ACO instructions and the installation details are set
watertight seal when screwed fully home into Technologies plc), ACO Business Centre, out on Drawing No. *.
the outlet body. Threaded outlets are Caxton Road, Bedford MK41 0LF.
recommended where connection to the outlet * please delete or complete as appropriate.
occurs within the thickness of the slab as
All components to be manufactured from
threaded connections will form a completely
grade LM6 aluminium silicon alloy to
gas-tight seal within the slab.
BS EN 1706:2010.

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO High Performance Rainwater Outlets

ACO HP Vertical Screw Outlet – Flat Grate

B Membrane

D
C
E

Nominal Bore Area Drained‡ Flow Rate† Weight


Part No Product Ref
Pipe Size (mm) (m²) (l/s) (kg)

105912 50HP-TF 50 82 1.7 2.50


105913 75HP-TF 75 240 5.0 2.50
105914 100HP-TF 100 514 10.7 3.70
105915 150HP-TF 150 736 15.9 3.80

† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).

Product Dimensions (mm)


Part No Product Ref Nominal bore pipe size
A B C D E

105912 50HP‐TF 50 300 260 45 130 2" BSP


105913 75HP‐TF 75 300 260 45 130 3" BSP
105914 100HP‐TF 100 380 310 45 130 4" BSP
105915 150HP‐TF 150 380 310 45 130 6" BSP

See Page 27 for ABS threaded adaptors

12

Pipework connections Specification clause


ACO threaded outlets are supplied with a The rainwater outlets 50HP-TF/75HP- All components used within the scope of this
parallel female screw thread to BS 21: 1985 TF/100HP-TF/150HP-TF* are to be ACO system are shown on Drawing No. * and all
for connection to tube conforming to BS EN Building Drainage HP vertical threaded outlets work shall be carried out strictly in
10255:2004 with male taper thread to with locked dome grating supplied by ACO accordance with the manufacturer’s
BS 21:1985. This ensures a completely Building Drainage (a division of ACO instructions and the installation details are set
watertight seal when screwed fully home into Technologies plc), ACO Business Centre, out on Drawing No. *.
the outlet body. Threaded outlets are Caxton Road, Bedford MK41 0LF.
recommended where connection to the outlet * please delete or complete as appropriate.
occurs within the thickness of the slab as
All components to be manufactured from
threaded connections will form a completely
grade LM6 aluminium silicon alloy to
gas-tight seal within the slab.
BS EN 1706:2010.

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Technical Data

ACO HP 45° Spigot Outlet – Dome Grate


A

Membrane

C
E
D

Nominal Bore Pipe OD Area Drained‡ Flow Rate† Weight


Part No Product Ref
Pipe Size (mm) (mm) (m²) (l/s) (kg)

105916 50/45HP-D 50 60 82 1.7 2.90


105917 75/45HP-D 75 83 240 5.0 3.50
105918 100/45HP-D 100 110 422 8.8 5.00

† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).

Product Dimensions (mm)


Part No Product Ref Nominal bore pipe size
A B C D E

105916 50/45HP‐D 50 300 260 245 135 60


105917 75/45HP‐D 75 300 260 260 160 83
105918 100/45HP‐D 100 380 310 275 200 110

13

Pipework connections Specification clause


45° spigot outlets may be directly connected The rainwater outlets 50/45HP-D/75/45HP- All components used within the scope of this
to the following: D/100/45HP-D* are to be ACO Building system are shown on Drawing No. * and all

 Cast iron pipework to BS 416:1990 or Drainage HP 45° spigot outlets with locked work shall be carried out strictly in

BS EN 877 :1999. dome grating supplied by ACO Building accordance with the manufacturer’s
Drainage (a division of ACO Technologies plc), instructions and the installation details are set
 PVC-U ‘O’-ring socketed pipe to
ACO Business Centre, Caxton Road, Bedford out on Drawing No. *.
BS 4514:2001 (for 75/45HP-D, and
MK41 0LF.
100/45HP-D outlets only).
 Connection to 50/45HP-D outlets via pipe * please delete or complete as appropriate.

couplings or heat shrink socket. All components to be manufactured from


grade LM6 aluminium silicon alloy to
BS EN 1706:2010.

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO High Performance Rainwater Outlets

ACO HP 45° Spigot Outlet – Flat Grate


A

NEW!
B Membrane

C
E
D

Nominal Bore Pipe OD Area Drained‡ Flow Rate† Weight


Part No Product Ref
Pipe Size (mm) (mm) (m²) (l/s) (kg)

105919 50/45HP-F 50 60 82 1.7 3.60


105920 75/45HP-F 75 83 240 5.0 4.00
105921 100/45HP-F 100 110 494 10.3 6.20

† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).

Product Dimensions (mm)


Part No Product Ref Nominal bore pipe size
A B C D E

105919 50/45HP‐F 50 300 260 245 135 60


105920 75/45HP‐F 75 300 260 260 160 83
105921 100/45HP‐F 100 380 310 275 200 110

14

Pipework connections Specification clause


45° spigot outlets may be directly connected The rainwater outlets 50/45HP-F/75/45HP- All components used within the scope of this
to the following: F/100/45HP-F* are to be ACO Building system are shown on Drawing No. * and all

 Cast iron pipework to BS 416:1990 or Drainage HP 45° spigot outlets with locked work shall be carried out strictly in

BS EN 877 :1999. flat grating supplied by ACO Building Drainage accordance with the manufacturer’s
(a division of ACO Technologies plc), instructions and the installation details are set
 PVC-U ‘O’-ring socketed pipe to
ACO Business Centre, Caxton Road, Bedford out on Drawing No. *.
BS 4514:2001 (for 75/45HP-F and
MK41 0LF.
100/45HP-F outlets only).
 Connection to 50/45HP-F outlets via pipe * please delete or complete as appropriate.

couplings or heat shrink socket. All components to be manufactured from


grade LM6 aluminium silicon alloy to
BS EN 1706:2010.

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Technical Data

ACO HP 45° Screw Outlet – Dome Grate


A

B
Membrane
NEW!

E
D

Nominal Bore Area Drained‡ Flow Rate† Weight


Part No Product Ref
Pipe Size (mm) (m²) (l/s) (kg)

105922 50/45HP-TD 50 82 1.7 3.10


105923 75/45HP-TD 75 240 5.0 2.60
105924 100/45HP-TD 100 418 8.7 4.40

† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).

Product Dimensions (mm)


Part No Product Ref Nominal bore pipe size
A B C D E

105922 50/45HP‐TD 50 300 260 190 80 2" BSP


105923 75/45HP‐TD 75 300 260 200 120 3" BSP
105924 100/45HP‐TD 100 380 310 210 145 4" BSP

See Page 27 for ABS threaded adaptors

15

Pipework connections Specification clause


ACO threaded outlets are supplied with a The rainwater outlets 50/45HP-TD/75/45HP- All components used within the scope of this
parallel female screw thread to BS 21: 1985 TD/100/45HP-TD* are to be ACO Building system are shown on Drawing No. * and all
for connection to tube conforming to BS EN Drainage HP 45° threaded outlets with locked work shall be carried out strictly in
10255:2004 with male taper thread to dome grating supplied by ACO Building accordance with the manufacturer’s
BS 21:1985. This ensures a completely Drainage (a division of ACO Technologies plc), instructions and the installation details are set
watertight seal when screwed fully home into ACO Business Centre, Caxton Road, Bedford out on Drawing No. *.
the outlet body. Threaded outlets are MK41 0LF.
recommended where connection to the outlet * please delete or complete as appropriate.
occurs within the thickness of the slab as
All components to be manufactured from
threaded connections will form a completely
grade LM6 aluminium silicon alloy to
gas-tight seal within the slab.
BS EN 1706:2010.

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO High Performance Rainwater Outlets

ACO HP 45° Screw Outlet – Flat Grate

B
Membrane
NEW!

E
D

Nominal Bore Area Drained‡ Flow Rate† Weight


Part No Product Ref
Pipe Size (mm) (m²) (l/s) (kg)

105925 50/45HP-TF 50 1.7 82 3.50


105926 75/45HP-TF 75 5.0 240 3.60
105927 100/45HP-TF 100 8.7 485 5.10

† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).

Product Dimensions (mm)


Part No Product Ref Nominal bore pipe size
A B C D E

105925 50/45HP‐TF 50 300 260 190 80 2" BSP


105926 75/45HP‐TF 75 300 260 200 120 3" BSP
105927 100/45HP‐TF 100 380 310 210 145 4" BSP

See Page 27 for ABS threaded adaptors

16

Pipework connections Specification clause


ACO threaded outlets are supplied with a The rainwater outlets 50/45HP-TF/75/45HP- All components used within the scope of this
parallel female screw thread to BS 21: 1985 TF/100/45HP-TF* are to be ACO Building system are shown on Drawing No. * and all
for connection to tube conforming to BS EN Drainage HP 45° threaded outlets with locked work shall be carried out strictly in
10255:2004 with male taper thread to flat grating supplied by ACO Building Drainage accordance with the manufacturer’s
BS 21:1985. This ensures a completely (a division of ACO Technologies plc), ACO instructions and the installation details are set
watertight seal when screwed fully home into Business Centre, Caxton Road, Bedford out on Drawing No. *.
the outlet body. Threaded outlets are MK41 0LF.
recommended where connection to the outlet * please delete or complete as appropriate.
occurs within the thickness of the slab as
All components to be manufactured from
threaded connections will form a completely
grade LM6 aluminium silicon alloy to
gas-tight seal within the slab.
BS EN 1706:2010.

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Technical Data

ACO HP 90° Spigot Outlet – Dome Grate

A
NEW!
B

Membrane

C
E
D

Nominal Bore Pipe OD Area Drained‡ Flow Rate† Weight


Part No Product Ref
Pipe Size (mm) (mm) (m²) (l/s) (kg)

105928 50/90HP-D 50 60 82 1.7 3.00


105929 75/90HP-D 75 83 240 5.0 3.00
105930 100/90HP-D 100 110 346 7.2 5.10

† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).

Product Dimensions (mm)


Part No Product Ref Nominal bore pipe size
A B C D E

105928 50/90HP‐D 50 300 260 130 230 60


105929 75/90HP‐D 75 300 260 130 230 83
105930 100/90HP‐D 100 380 310 160 290 110

17

Pipework connections Specification clause


90° spigot outlets may be directly connected The rainwater outlets 50/90HP-D/75/90HP- All components used within the scope of this
to the following: D/100/90HP-D* are to be ACO Building system are shown on Drawing No. * and all

 Cast iron pipework to BS 416:1990 or Drainage HP 90° spigot outlets with locked work shall be carried out strictly in

BS EN 877 :1999. dome grating supplied by ACO Building accordance with the manufacturer’s
Drainage (a division of ACO Technologies plc), instructions and the installation details are set
 PVC-U ‘O’-ring socketed pipe to
ACO Business Centre, Caxton Road, Bedford out on Drawing No. *.
BS 4514:2001 (for 75/90HP-D and
MK41 0LF.
100/90HP-D outlets only).
 Connection to 50/90HP-D outlets via pipe * please delete or complete as appropriate.

couplings or heat shrink socket. All components to be manufactured from


grade LM6 aluminium silicon alloy to BS EN
1706:2010..

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO High Performance Rainwater Outlets

ACO HP 90° Spigot Outlet – Flat Grate

A
NEW!
B
Membrane

C
E
D

Nominal Bore Pipe OD Area Drained‡ Flow Rate† Weight


Part No Product Ref
Pipe Size (mm) (mm) (m²) (l/s) (kg)

105931 50/90HP-F 50 60 82 1.7 3.30


105932 75/90HP-F 75 83 192 4.0 3.40
105933 100/90HP-F 100 110 398 8.3 6.00

† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).

Product Dimensions (mm)


Part No Product Ref Nominal bore pipe size
A B C D E

105931 50/90HP‐F 50 300 260 130 230 60


105932 75/90HP‐F 75 300 260 130 230 83
105933 100/90HP‐F 100 380 310 160 290 110

18

Pipework connections Specification clause


90° spigot outlets may be directly connected The rainwater outlets 50/90HP-F/75/90HP- All components used within the scope of this
to the following: F/100/90HP-F* are to be ACO Building system are shown on Drawing No. * and all

 Cast iron pipework to BS 416:1990 or Drainage HP 90° spigot outlets with locked work shall be carried out strictly in

BS EN 877 :1999. flat grating supplied by ACO Building Drainage accordance with the manufacturer’s
(a division of ACO Technologies plc), ACO instructions and the installation details are set
 PVC-U ‘O’-ring socketed pipe to
Business Centre, Caxton Road, Bedford out on Drawing No. *.
BS 4514:2001 (for 75/90HP-F and
MK41 0LF.
100/90HP-F outlets only).
 Connection to 50/90HP-F outlets via pipe * please delete or complete as appropriate.

couplings or heat shrink socket. All components to be manufactured from


grade LM6 aluminium silicon alloy to
BS EN 1706:2010.

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Technical Data

ACO HP 90° Screw Outlet – Dome Grate

A NEW!
B

Membrane

C
E
D

Nominal Bore Area Drained‡ Flow Rate† Weight


Part No Product Ref
Pipe Size (mm) (m²) (l/s) (kg)

105934 50/90HP-TD 50 82 1.7 2.90


105935 75/90HP-TD 75 182 3.8 2.90
105936 100/90HP-TD 100 341 7.1 4.70
105937 150/90HP-TD 150 507 10.6 4.90

† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).

Product Dimensions (mm)


Part No Product Ref Nominal bore pipe size
A B C D E

105934 50/90HP‐TD 50 300 260 130 160 2" BSP


105935 75/90HP‐TD 75 300 260 130 160 3" BSP
105936 100/90HP‐TD 100 380 310 170 190 4" BSP
105937 150/90HP‐TD 150 380 310 215 140 6" BSP

See Page 27 for ABS threaded adaptors

19

Pipework connections Specification clause


ACO threaded outlets are supplied with a The rainwater outlets 50/90 HP-TD/75/90HP- All components used within the scope of this
parallel female screw thread to BS 21: 1985 TD/100/90 HP-TD/150/90 HP-TD* are to be system are shown on Drawing No. * and all
for connection to tube conforming to BS EN ACO Building Drainage HP 90° threaded work shall be carried out strictly in
10255:2004 with male taper thread to outlets with locked dome grating supplied by accordance with the manufacturer’s
BS 21:1985. This ensures a completely ACO Building Drainage (a division of ACO instructions and the installation details are set
watertight seal when screwed fully home into Technologies plc), ACO Business Centre, out on Drawing No. *.
the outlet body. Threaded outlets are Caxton Road, Bedford MK41 0LF.
recommended where connection to the outlet * please delete or complete as appropriate.
occurs within the thickness of the slab as
All components to be manufactured from
threaded connections will form a completely
grade LM6 aluminium silicon alloy to
gas-tight seal within the slab.
BS EN 1706:2010.

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO High Performance Rainwater Outlets

ACO HP 90° Screw Outlet – Flat Grate

A
NEW!
B
Membrane

C
E
D

Nominal Bore Area Drained‡ Flow Rate† Weight


Part No Product Ref
Pipe Size (mm) (m²) (l/s) (kg)

105938 50/90HP-TF 50 82 1.7 3.30


105939 75/90HP-TF 75 197 4.1 3.20
105940 100/90HP-TF 100 389 8.1 5.50
105941 150/90HP-TF 150 624 13.0 5.00

† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).

Product Dimensions (mm)


Part No Product Ref Nominal bore pipe size
A B C D E

105938 50/90HP‐TF 50 300 260 130 160 2" BSP


105939 75/90HP‐TF 75 300 260 130 160 3" BSP
105940 100/90HP‐TF 100 380 310 170 190 4" BSP
105941 150/90HP‐TF 150 380 310 215 140 6" BSP

See Page 27 for ABS threaded adaptors

20

Pipework connections Specification clause


ACO threaded outlets are supplied with a The rainwater outlets 50/90HP-TF/75/90HP- All components used within the scope of this
parallel female screw thread to BS 21: 1985 TF/100/90HP-TF/150/90HP-TF* are to be system are shown on Drawing No. * and all
for connection to tube conforming to BS EN ACO Building Drainage HP 90° threaded work shall be carried out strictly in
10255:2004 with male taper thread to outlets with locked flat grating supplied by accordance with the manufacturer’s
BS 21:1985. This ensures a completely ACO Building Drainage (a division of ACO instructions and the installation details are set
watertight seal when screwed fully home into Technologies plc), ACO Business Centre, out on Drawing No. *.
the outlet body. Threaded outlets are Caxton Road, Bedford MK41 0LF.
recommended where connection to the outlet * please delete or complete as appropriate.
occurs within the thickness of the slab as
All components to be manufactured from
threaded connections will form a completely
grade LM6 aluminium silicon alloy to
gas-tight seal within the slab.
BS EN 1706:2010.

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Technical Data

ACO HP Balcony Spigot Outlet – Flat Grate

A 230

B 160
Membrane

C
E

D
G
F

Nominal Bore Pipe OD Area Drained‡ Flow Rate† Weight


Part No Product Ref
Pipe Size (mm) (mm) (m²) (l/s) (kg)

105942 50HP-BO 50 60 82 1.7 2.60


105943 75HP-BO 75 83 240 5.0 2.60
105944 100HP-BO 100 110 345 7.6 2.80

† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).

Product Dimensions (mm)


Part No Product Ref Nominal bore pipe size
A B C D E F G

105942 50HP‐BO 50 265 205 90 125 215 210 60


105943 75HP‐BO 75 265 205 90 125 215 210 83
105944 100HP‐BO 100 265 205 90 125 215 210 110

21

Pipework connections Specification clause


Vertical spigot outlets may be directly The rainwater outlets 50HP-BO/75HP- All components used within the scope of this
connected to the following: BO/100HP-BO* are to be ACO Building system are shown on Drawing No. * and all

 Cast iron pipework to BS 416:1990 or Drainage HP vertical spigot outlets with work shall be carried out strictly in

BS EN 877 :1999. locked flat grating supplied by ACO Building accordance with the manufacturer’s
Drainage (a division of ACO Technologies plc), instructions and the installation details are set
 PVC-U ‘O’-ring socketed pipe to BS
ACO Business Centre, Caxton Road, Bedford out on Drawing No. *.
4514:2001 (for 75HP-BO and 100HP-BO
MK41 0LF.
outlets only).
 Connection to 50HP-BO outlets via pipe * please delete or complete as appropriate.

couplings or heat shrink socket. All components to be manufactured from


grade LM6 aluminium silicon alloy to
BS EN 1706:2010.

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO High Performance Rainwater Outlets

ACO HP Two-Way Screw Outlet – Flat Grate

E
Membrane
A

B
F
C

Nominal Bore Area Drained‡ Flow Rate† Weight


Part No Product Ref
Pipe Size (mm) (m²) (l/s) (kg)

105945 50HP-TW 50 82 1.7 2.10


105946 75HP-TW 75 197 4.1 2.20
105947 100HP-TW 100 374 7.8 2.20

† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).

Product Dimensions (mm)


Part No Product Ref Nominal bore pipe size
A B C D E F

105945 50HP‐TW 50 202 70 193 213 50 2" BSP


105946 75HP‐TW 75 202 70 193 213 50 3" BSP
105947 100HP‐TW 100 202 70 193 213 50 4" BSP

See Page 27 for ABS threaded adaptors

22

Pipework connections Specification clause


ACO threaded outlets are supplied with a The rainwater outlets 50HP-TW/75HP- All components used within the scope of this
parallel female screw thread to BS 21: 1985 TW/100HP-TW* are to be ACO Building system are shown on Drawing No. * and all
for connection to tube conforming to BS EN Drainage HP threaded outlets with locked work shall be carried out strictly in
10255:2004 with male taper thread to grating supplied by ACO Building Drainage accordance with the manufacturer’s
BS 21:1985. This ensures a completely (a division of ACO Technologies plc), ACO instructions and the installation details are set
watertight seal when screwed fully home into Business Centre, Caxton Road, Bedford out on Drawing No. *.
the outlet body. Threaded outlets are MK41 0LF.
recommended where connection to the outlet * please delete or complete as appropriate.
occurs within the thickness of the slab as
All components to be manufactured from
threaded connections will form a completely
grade LM6 aluminium silicon alloy to
gas-tight seal within the slab.
BS EN 1706:2010.

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Technical Data

ACO HP Gully Spigot Outlet – Dome Grate

A C
B D

Membrane

G
E

Nominal Bore Pipe OD Area Drained‡ Flow Rate† Weight


Part No Product Ref
Pipe Size (mm) (mm) (m²) (l/s) (kg)

105948 75HP-GO 75 80 240 5.0 3.10


105949 100HP-GO 100 110 514 10.7 3.40

† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).

Product Dimensions (mm)


Part No Product Ref Nominal bore pipe size
A B C D E F G

105948 75HP‐GO 75 345 260 240 160 80 230 125


105949 100HP‐GO 100 345 260 240 160 110 230 125

23

Pipework connections Specification clause


Vertical spigot outlets may be directly The rainwater outlets 75HP-GO/100HP-GO* All components used within the scope of this
connected to the following: are to be ACO Building Drainage HP vertical system are shown on Drawing No. * and all

 Cast iron pipework to BS 416:1990 or spigot outlets with locked dome grating work shall be carried out strictly in

BS EN 877 :1999. supplied by ACO Building Drainage (a division accordance with the manufacturer’s
of ACO Technologies plc), ACO Business instructions and the installation details are set
 PVC-U ‘O’-ring socketed pipe to
Centre, Caxton Road, Bedford MK41 0LF. out on Drawing No. *.
BS 4514:2001.

All components to be manufactured from * please delete or complete as appropriate.

grade LM6 aluminium silicon alloy to


BS EN 1706:2010.

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO High Performance Rainwater Outlets

ACO HP Gully Refurbishment Outlet – Dome Grate

A
B
D NEW!
Membrane

C
F

G
E

Nominal Bore Area Drained‡ Flow Rate† Weight


Part No Product Ref
Pipe Size (mm) (m²) (l/s) (kg)

105950 75HP-RFO 75 240 5.0 7.70


105951 100HP-RFO 100 240 5.0 8.20

† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).

Product Dimensions (mm)


Part No Product Ref Nominal bore pipe size
A B C D E F G

105950 75HP‐RFO 75 494 354 50 236 89 64 285


105951 100HP‐RFO 100 494 354 50 236 114 89 285

24

Pipework connections Specification clause


Refurbishment outlets are designed to fit the The rainwater outlets 75HP-RFO/100HP- All components used within the scope of this
following range of existing pipework systems: RFO* are to be ACO Building Drainage HP system are shown on Drawing No. * and all

 75HP-RFO : 71.5 to 78.5mm internal vertical spigot outlets with locked dome work shall be carried out strictly in

diameter. grating supplied by ACO Building Drainage accordance with the manufacturer’s
(a division of ACO Technologies plc), ACO instructions and the installation details are set
 100HP-RFO : 97.0 to 104.0 mm
Business Centre, Caxton Road, Bedford out on Drawing No. *.
diameter.
MK41 0LF.

* please delete or complete as appropriate.

All components to be manufactured from


grade LM6 aluminium silicon alloy to
BS EN 1706:2010.

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Technical Data

ACO HP Overflow Outlet Module – Dome Grate

NEW!

D
A*

A*
B B

105952 105953
ØC
ØC

Nominal Bore Flow Rate† Weight


Part No Product Ref
Pipe Size (mm) (l/s) (kg)

105952 50/75HP-OF 50 2.4 2.20


105953 100/150HP-OF 75 2.4 2.70

† 35mm head of water over outlet

* Easy cut on site to suit application.

Product Dimensions (mm)


Part No Product Ref Nominal bore pipe size
A B C D

105952 50/75HP‐OF 75 310 90 215 95


105953 100/150HP‐OF 100 310 90 273 95

25

Overflow modules are easily attached to an Overflow units are supplied with a PVC tube
appropriate circular 50/75HP or 100/150HP 250mm long that can be easily cut on site to
rainwater outlets in applications where grating the maximum permissible overflow height
blockage from leaves, for example, would lead required for the application. Overflow units are
to an excessive accumulation of water on the used in conjunction with an appropriate spigot
roof area. Unplanned excess water on the roof outlet unit.
area can lead to over-spill to the sides of the
building and significantly increase the load
applied to the roof structure.

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO High Performance Rainwater Outlets

ACO Raising Rings for Circular Outlets

A A

B
C C

105954 105955

50/75RR 100/150RR

Product Dimensions (mm)


Part No Product Ref Suitable for Outlet Product Ref Weight
A B C (kg)

50HP-D; 75HP-D; 50HP-F; 75HP-F; 50HP-TD; 75HP-TD;


50HP-TF; 75HP-TF; 50/45HP-D; 75/45HP-D; 50/45HP-F;
75/45HP-F; 50/45HP-TD; 75/45HP-TD; 50/45HP-TF;
105954 50/75RR 230 125 170 1.50
75/45HP-TF; 50/90HP-D; 75/90HP-D; 50/90HP-F;
75/90HP-F; 50/90HP-TD; 75/90HP-TD; 50/90HP-TF;
75/90HP-TF
100HP-D; 150HP-D; 100HP-F; 150HP-F; 100HP-TD;
150HP-TD; 100HP-TF; 150HP-TF; 100/45HP-D;
105955 100/150RR 150/45HP-D; 100/45HP-F; 100/45HP-TD; 100/45HP-TF; 230 125 170 1.40
100/90HP-D; 100/90HP-F; 100/90HP-TD; 150/90HP-TD;
100/90HP-TF; 150/90HP-TF

ACO Raising Rings for Balcony and Gully Outlets

26
A C A C
B

D E D E

105956 105957

HPBO-RR HPGO-RR

Product Dimensions (mm)


Weight
Part No Product Ref Suitable for Outlet Product Ref
(kg)
A B C D E

105956 HPBO-RR 50HP-BO; 75HP-BO; 100HP-BO 207 117 150 177 115 0.80
105957 HPGO-RR 75HP-GO; 100HP-GO 240 125 145 200 105 1.60

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Technical Data

ACO ABS Threaded Adaptors

For use with ACO Building Drainage Screw Rainwater Outlets.

150

B
Male Thread (A)

Male Thread Spigot Dia Length Weight


Part No Product Ref
A (BSP) B (mm) L (mm) (kg)

105958 50STC 2” 55 300 0.30


105959 75STC 3” 83 300 0.60
105960 100STC 4” 110 300 1.00
105961 150STC 6” 160 300 1.60

ACO Discharge Spouts

Discharge spouts provide a convenient and aesthetically pleasing finishing detail to attach to a parapet/vertical wall outlet pipe. Manufactured from
LM6 aluminium silicon alloy they can be directly connected to ACO Building Drainage ABS Threaded Adaptors with a watertight seal and secured to
the vertical wall using two fixing lugs. Discharge spout projection from the vertical wall’s: 40mm.

27

A A A
B

C C C
D D D
105962 105963 105964

Product Dimensions (mm) Weight


Part No Product Ref
(kg)
A B C D

105962 50HP-SPOUT 75 150 135 64 1.20


105963 75HP-SPOUT 75 150 135 92 1.10
105964 100HP-SPOUT 75 150 135 118 0.90

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO High Performance Rainwater Outlets

ACO Terrace Grate for Circular Outlet Raising Rings

Terrace grates are designed for installations with terraced paving slabs or block paviors. Terrace grates can only be used with raising rings for circular
outlets as shown on Page 26. A slotted fixing detail allows 90° rotational movement to accommodate slab/pavior patterns.

250

16
230
All dimensions in mm

Weight
Part No Product Ref Grating Size (mm)
(kg)

105965 HPTG 230 x 230 x 16 1.30

Requires 50/75RR or 100/150RR as applicable

ACO Deck Supports for Circular Outlets

Deck supports are used where ACO Building Drainage HP Rainwater Outlets are installed in metal deck roof constructions, providing a stable and
secure interface between the outlet and roof. Deck Supports are manufactured from mild steel and primed in a red oxide paint finish and finished in a
polyester powder coat. They are suitable for all types of roof decking.
600

600
395

395
70
15

Ø2
Ø3

28

395 395
600 600
105966 105967

Weight
Part No Product Ref Suitable for Outlet Product Ref
(kg)

50HP-D; 75HP-D; 50HP-TD; 75HP-TD; 50/45HP-D; 75/45HP-D; 50/45HP-TD; 75/45HP-TD;


105966 50/75DS 2.20
50/90HP-D; 75/90HP-D; 50/90HP-TD; 75/90HP-TD
100HP-D; 150HP-D; 100HP-TD; 150HP-TD; 100/45HP-D; 150/45HP-D; 100/45HP-TD;
105967 100/150DS 2.50
100/90HP-D; 100/90HP-TD; 150/90HP-TD

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Technical Data

ACO Car Park Gullies


NEW!

ACO Building Drainage cast iron Car Park Key benefits Key features
Gullies are designed specifically for trafficked
 Durable, robust cast iron construction  Stainless steel bolted grating for security
car park applications with direct vehicle
access providing a robust, compact and  Low profile design for shallow deck  110mm spigot outlet for easy pipe

durable drainage solution. installations connection


 Quick installation  Choice of horizontal or vertical outlet

Car Park gullies are ideal for multi-storey car  Load Class M125 (12.5 tonne) grating to  Removable galvanised steel dirt bucket

parks, shallow parking deck or podium deck BS EN 1253  Optional drainage weep hole facility
applications and particularly suited for high  Locked grating  Optional intumescent fire stop cartridge
traffic frequency.  High flow rate – large area drainage R120/2 hour rating (vertical outlet
 Easy maintenance versions only) 29

 Fire proof – Class A1  Black water-based paint finish

Shallow deck installation with 110mm Through deck installation with 110mm vertical
horizontal outlet with weep-hole drainage outlet complete with locked grating, galvanised
facility. Complete with locked grating and steel dirt bucket and R120/2 hour fire stop
galvanised steel dirt bucket. cartridge fitted.

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO Car Park Gullies

ACO Car Park Gully - Vertical Outlet, Framed


NEW!

300
300
110
Ø110 16

300

All dimensions in mm

Spigot Dia Flow Rate† Area Drained‡ Flanged & Galvanised Weight
Part No Load Class Grating Locks
(mm) (l/s) (m²) Weep Holes Dirt Bucket (kg)

105980 110 4.5 216 No M125 Yes Yes 35.00

† 35mm head of water


‡ Rainfall intensity 75mm/hr (0.02083 l/s/m²)

ACO Car Park Gully - Vertical Outlet, Flanged Weep Hole


NEW!
50

450
300
300
110

30

Ø110
16
300
450

All dimensions in mm

Spigot Dia Flow Rate† Area Drained‡ Flanged & Galvanised Weight
Part No Load Class Grating Locks
(mm) (l/s) (m²) Weep Holes Dirt Bucket (kg)

105982 110 4.5 216 Yes M125 Yes Yes 47.00

† 35mm head of water


‡ Rainfall intensity 75mm/hr (0.02083 l/s/m²)

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Technical Data

ACO Car Park Gully - Horizontal Outlet, Framed


NEW!

300
180


Ø110
16
339 300

All dimensions in mm

Spigot Dia Flow Rate† Area Drained‡ Flanged & Galvanised Weight
Part No Load Class Grating Locks
(mm) (l/s) (m²) Weep Holes Dirt Bucket (kg)

105981 110 4.5 216 No M125 Yes Yes 40.00

† 35mm head of water


‡ Rainfall intensity 75mm/hr (0.02083 l/s/m²)

ACO Car Park Gully - Horizontal Outlet, Flanged Weep Hole NEW!
50

450

300
180

Ø110

31

339
16
300

450

All dimensions in mm

Spigot Dia Flow Rate† Area Drained‡ Flanged & Galvanised Weight
Part No Load Class Grating Locks
(mm) (l/s) (m²) Weep Holes Dirt Bucket (kg)

105983 110 4.5 216 Yes M125 Yes Yes 52.00

† 35mm head of water


‡ Rainfall intensity 75mm/hr (0.02083 l/s/m²)

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO Car Park Gullies - Accessories

Accessories
NEW!
Raising Ring 45mm

45

30
300
300
All dimensions in mm

Part No Clearance Holes for Grating Locks Weight (kg)

105984 Yes 7.90

Raising rings are suitable for all ACO Building Drainage Car Park Gullies and may be cascaded in increments of 45mm. Extension bolts for grating
locks not provided. M12 x 35mm stainless steel cap head screws supplied as standard.

Intumescent Fire Stop


NEW!
Ø127
127

All dimensions in mm

32
Part No Fire Rating Weight (kg)

105985 R30-120 0.30

Intumescent fire stop can only be used with vertical outlet Car Park Gullies. Please note that the Car Park gully flow rate is restricted to 3 l/s when a
fire stop is fitted (144m² area drained at a rainfall intensity of 75mm/hr (0.02083 l/s/m²).

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Installation Recommendations

Typical Flat Roof Construction Details

Warm Roof
Raising Ring
A warm roof is where the main mass of the
Two Layer mastic Ashpalt
roof structure lies below the main thermal
Reflective Layer Secure Bolted Grating
insulation. The waterproof membrane is of Chippings
Clamping Ring
positioned above the insulation.

Rigid Insulation Board

Sand / Cement Screed


To Falls

Vapour Barrier
Structural Deck
Outlet Body

Raising Ring

Secure Bolted Grating


Inverted Roof
Gravel Ballast Clamping Ring

An inverted roof is a form of warm roof where


the main mass of the roof structure lies below
Rigid Insulation Board
the main thermal insulation, however, the
waterproof membrane lies beneath the
thermal insulation.
Sand / Cement Screed
To Falls

Two Layer Mastic Ashphalt 33


on Isolating Membrane Structural Deck
Outlet Body

Secure Bolted Grating

Un-insulated Roof
Clamping Ring

A roof without thermal insulation. This type of


construction is only permitted in non-
habitable buildings, e.g. garages.

Two Layer Mastic Ashphalt


In Situ Cast Concrete Deck
on Isolating Membrane

Outlet Body

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO High Performance Rainwater Outlets

Typical Installation Guide & Construction Detail

HP 90° outlet Three Layer Built up Felt Roof Secure Bolted Grating

Clamping Ring

Firring Piece
Plywood Deck

Timber Joist
Insulation

Outlet Body Plaster ceiling with Internal Vapour Barrier

Secure Bolted Domical Grate

Gully outlet Clamping Ring


Sheet Lead Gutter Lining

Plywood Base

Insulated Gutter
Rigid Insulation Board

Ply Sub-base
Timber Spacers in
Insulated Gutter

34 Outlet Body

Refurbishment outlet
Main Waterproofing
ACO HP Refurbishment Outlet
(Fitted as Manufacturers Recommendations)
Refurbishment Insululation

New vapour barrier laid onto Structural Deck


cleaned existing roof

Refurbishment Outlet Spigot cut as required


Original Outlet Body

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Installation Recommendations

Typical Installation Guide & Construction Detail

RWP

Flat Grate with


Balcony outlet with downpipe RWP cut-out

Two Layer Mastic Ashphalt


Clamping Ring on Isolating Membrane

Sand / Cement Screed


To Falls

Structural Deck

Outlet Body

Two-way outlet

Outlet Body Reflective Chippings on Three


Screw Thread Connector
Layer Built Up Felt Roofing
Clamping Ring

Rigid Insulation Board

Vapour Barrier
35

Structural Deck

Two-way outlet with spout

Reflective Chippings on Three


Layer Built Up Felt Roofing
Outlet Body
Screw Thread Connector

Clamping Ring

Spout

Rigid Insulation Board

Vapour Barrier
Structural Deck
Hopper & RWP
(by others)

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO High Performance Rainwater Outlets

Typical Installation Guide & Construction Detail

Terrace grate

Paving Slab Ballasting


Terrace Grate
Paving Slab Supports
Raising Ring

Rigid Insulation Board

Sand / Cement Screed


To Falls

Structural Deck

Two Layer Mastic Ashphalt


on Isolating Membrane
Outlet Body

Metal deck support


36

Rigid Insulation Board


Timber Fillet
with integral vapour barrier to falls

Secure Bolted Grating


Three Layer Built up Felt Roof
Clamping Ring

Metal Deck

Deck Support

Metal Closure Plate

Outlet Body

Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Appendices

Refurbishment Outlet installation Guide

Step 1 Step 2
Remove redundant roofing materials; brush & clean surfaces ready for Lay new vapour barrier & bond into existing rainwater outlet.
new installation.

Step 3 Step 4
With the finned rubber seal removed, insert the ACO Refurbishment Bond strips of vapour barrier to the Refurbishment Outlet flanges and
Outlet into the sump of the existing rainwater outlet body. If necessary, existing vapour barrier to ensure a total seal.
reduce the spigot length of the new outlet to allow full insertion.
Replace rubber seal and re-insert. 37

Step 5 Step 6 Step 7


Cut and lay insulation board around Lay main waterproofing material over entire With the waterproofing material still pliable,
refurbishment outlet. If insulation is greater area and trim into the sump of the install clamping ring and tighten nuts evenly.
than 50mm thick, chamfer board so that refurbishment outlet, ensuring the spigot Fit the grating to complete the installation.
outlet is at same level as the outlet top outlet is clear or waterproofing material.
surface.
ACO High Performance Rainwater Outlets

Associated ACO Building Drainage Product Ranges

ACO Engineered Solutions

ACO Engineered Solutions offer the designer / specifier a Examples of ACO Engineered Solution applications include:
range of products virtually free from the constraints of ‘off ∙ Workable drainage where there is limited invert depths
the shelf’ items. Our engineers are able to offer detailed
∙ Refurbishment situations with replacement channels and
advice on all aspects of required design solutions, together
point drainage
with hydraulic flow analysis, practical site installation,
suitable materials and best practices. ACO Engineered ∙ Interface with threshold details

Solutions enjoy rigorous product management from initial ∙ Discreet channel applications
enquiry through to post-delivery. ∙ Radius channel applications

Uniclass July 2011


L73144
CI/SfB
(52.5) ACO Building Drainage
Drainage Systems

ACO FreeDeck

ACO FreeDeck is an advanced roof and balcony drainage system combining


line drainage with point drainage by using an open sided drainage channel
system to collect and convey rainwater to drainage points within a raised or
suspended deck structure. Manufactured in galvanised steel or stainless steel,
ACO FreeDeck channel is simply laid directly onto the insulation layer or Product catalogue
ACO FreeDeck - Level Access Flat Roof
waterproofing membrane. and Terrace Drainage Systems

38

ACO Building Drainage


Dr a i nage Syste ms

ACO DeckLine 125

ACO DeckLine 125 is a shallow invert hot-dipped galvanised steel linear


drainage system for applications up to and including Load Class C 250. It is
ideally suited for parking decks and areas such as structural slabs or where
excavation depth is limited. Available off the shelf ACO DeckLine is durable,
100% watertight and easy to install. ACO DeckLine 125 is tested and Product catalogue
ACO Deckline 125
certified to BS EN 1433. Galvanised Steel
Shallow Invert Surface Water Drainage System

All product brochures are available for viewing and downloading at www.acobd.co.uk
Associated ACO Building Drainage Product Ranges

Associated ACO Building Drainage Product Ranges

ACO Building Drainage


Pipework Systems

ACO PIPE®

ACO PIPE® is manufactured from thin-wall austenitic stainless steel in grades


304 and 316 and is pickle passivated for optimum durability and corrosion
resistance. ACO PIPE® is available in a wide range of socketed waste pipework
products and accessories for above and below ground rainwater and industrial
wastewater drainage applications. Used together with other ACO products it
creates a perfect system and one stop sustainable drainage solution with
unique advantages to the customer – lightweight, easy installation, low
Product catalogue
thermal expansion co-efficient, sustainable material, hygienic, near zero ACO PIPE® Stainless Steel Pipework Systems

maintenance. When used with ACO stainless steel gullies and channel systems
it provides a unique system for building drainage.

#! " '' &

ACO Building Drainage


Drainage Systems

ACO Modular 125

ACO Modular 125 Stainless Steel linear drainage is our most requested product
range as it is suitable for most applications. ACO Modular 125 is manufactured in
stainless steel grade 304 as standard and 316 to order. Available in a wide range of
lengths, constant depths, sloping inverts and gratings ‘off the shelf’, it can be
modified to meet your exact application requirements. Used together with ACO Gully 39
®
157 or 218 and ACO PIPE it offers the specifier, contractor and user the benefits of
a unified system for building drainage and one stop drainage solution with unique
advantages – fully tested and classified to BS EN 1433, CE marked, pickle Product catalogue

ACO Modular 125


passivated for optimum durability and corrosion resistance, vee-bottomed profiled
Stainless Steel Channel Drainage System

channel for enhanced flow efficiency, optional grating security locks and lightweight
channel sections for safe and easy installation.
ACO Technologies plc

ACO Building Drainage

ACO Water Management


Civils + Infrastructure
Urban + Landscape

ACO Sport

ACO Wildlife

ACO Building Drainage

A division of ACO Technologies plc


ACO Business Centre
Caxton Road
Bedford
Bedfordshire
MK41 0LF
Tel: 01462 810400
Fax: 01462 851490

e-mail: [email protected]
www.acobd.co.uk

The ACO Group: A strong family you can depend on.

© April 2015 ACO Technologies plc. All reasonable care has been taken in compiling the information in this document. All
recommendations and suggestions on the use of ACO products are made without guarantee since the conditions of use are beyond
the control of the Company. It is the customer's responsibility to ensure that each product is fit for its intended purpose, and that the
actual conditions of use are suitable. This brochure and any advice is provided by ACO Technologies plc (the Company) free of
charge and accordingly on terms that no liability including liability for negligence will attach to the Company or its servants or
agents arising out of or in connection with or in relation to this brochure or any such advice. Any goods supplied by the Company
will be supplied solely upon its standard conditions of sale, copies of which are available on request. The Company's policy of
continuous product development and improvement renders specifications liable to modification. Information provided in this
brochure is therefore subject to change without prior notification.