Aco Rainwater Outlets Brochure
Aco Rainwater Outlets Brochure
Aco Rainwater Outlets Brochure
L73144
CI/Sf6 S2
(52.5) ACO Building Drainage
Dr ai nage Syste ms
Pipe Systems
*Available in 2015
www.acobd.co.uk
ACO High Performance Rainwater Outlets
Contents
Materials 4
Standard References 4
System Overview
The past few years have seen major advances All ACO Building Drainage High Performance ACO Building Drainage High Performance
and improvements in the materials used in Rainwater Outlets are manufactured from die- Rainwater Outlets - page 8
modern roofing technology. A specifier now cast marine-grade LM6 aluminium silicon Flat roofs
has renewed confidence to take full advantage alloy. This grade of aluminium alloy is highly
Low-pitched roofs
of the benefits flat and low-pitched roof corrosion resistant, weather-proof and
designs can offer. resistant to ultra-violet radiation. Balconies
Roof terraces
Flat roofs provide opportunities for planning All cast components are polyester powder
and design flexibility, for example; terracing, coated. For additional protection, this tough ACO Building Drainage Car Park Gullies
roof-top gardens, patios, car parks, delivery and resilient powder coated finish prevents - page 29
areas, building services and ventilation natural galvanic corrosion in applications
Multi storey car parks
equipment and the ability to add additional where dissimilar metals are dressed into the
Parking decks
storeys at a later date. outlets. 304 stainless steel fixings are used to
ensure long-service durability and reliability.
Large area roofs or irregular shaped buildings Standard References:
can be completed more quickly, easily and All ACO Building Drainage Rainwater Outlets
Design requirements and flow rate
cost effectively than a pitched roof. are available in leaded gun metal to BS EN
performance refer to EN 1253:2015 Gullies
1982:2008 to special order for lead or
for Buildings – Part 2: Roof drains and floor
Flat roofs also allow easy access to natural copper-clad roofs or connection to copper
gullies without trap.
light and because of the simple construction, pipework.
internal partitioning is easy and particularly
Roof drainage layout and hydraulic
advantageous for commercial or industrial ACO Building Drainage Car Park Gullies are
calculations refer to BS EN 12056-3:2000
buildings. manufactured from grey cast iron for robust
Gravity drainage systems inside buildings –
and durable applications to accommodate
Part 3: Roof drainage, layout and calculation.
heavy and frequent vehicle loads.
The following notes are intended as a guide to Rainfall intensity has a direct impact on the The runoff, or flow rate Q, from roofs, paved
the specifier who is designing a rainwater performance requirements of any rainwater areas as surfaces is calculated as follows and
drainage system for a roof. It is recommended drainage system. For roofs and paved areas, assumes that all surfaces are impermeable:
to refer to BS EN 12056-3:2000 Gravity it is normally impracticable to guard against
drainage systems inside buildings – Part 3: very infrequent, extremely heavy rainfall AxI
Roof drainage, layout and calculation for a situations so the designer should aim to strike Q = --------- litres/second
comprehensive design guide. a balance between the cost of the drainage 3600
system, the risk category of the building and
For any rainwater drainage system to work the frequency and subsequent consequences where
effectively and reliably, it is recommended the of flooding in the advent of particularly high
specifier considers the following: rainfall events. Q = Volumetric flow rate (l/s)
Geographical location of the building The United Kingdom experiences complex and A = Effective catchment area (m²)
varied rainfall patterns, for example; although
Rainfall intensity
the upland areas of northern and western I = Rainfall intensity (75mm/hr)
Storm duration and return period
parts of the British Isles experience higher
Effective catchment area of roof
average annual rainfall than the lowland areas
Risk category of the building however, the lowland areas experience more
Hydraulic capacity of the drainage frequent and more intense short duration Alternatively,
system(s) employed rainfall than the upland areas. BS EN 12056-
3:2000 provides further information and Q = r x A litres/second
guidance on this topic.
where
Practical Design Tips
A rainfall intensity of 75mm/hr
When designing an engineered rainwater (0.02083 l/s/m²) is used throughout Q = Volumetric flow rate (l/s)
scheme, the following design hints are this design catalogue.
suggested: r = Rainfall intensity (l/s/m²)
Do not design for the maximum outlet
hydraulic capacity. Allow a 10% factor of A = Effective catchment area (m²)
safety margin for intense storms and
leaf/debris blockage. For reference, a rainfall intensity of 75mm/hr
Always allow for a back-up outlet, even = 0.02083 l/s/m²
though only one outlet may be required.
5
Rainwater outlets should be inspected and
cleaned at least every 6 months to ensure Note. Using either of the formulae above to
reliable and continuous operation. calculate runoff (Q), for a given rainfall
intensity and by knowing the flow rate
performance of an individual rainwater outlet,
the effective roof area drained can be
calculated.
BR
Catchment area A
Catchment Area
TR2
D= LR x TR1 (m²)
TR1
Catchment area B
ACO HP vertical spigot outlet ACO HP two-way screw outlet ACO HP 45° & 90° outlets
General purpose rainwater outlets suitable for The two-way outlet is designed to be used at These angled problem solving outlets are
convenient direct connection to PVC-U ‘O’-ring the junction of roofs and parapet walls, or particularly relevant to suit more complex pipe
socket pipe to BS 4514:2001 or to cast iron wherever horizontal and vertical surfaces meet. run detail. Pipework connections as spigot or
pipework to BS 416:1990 or BS EN 877: This flexible design of outlet allows either a screwed outlets.
1999. Other connections can be made using horizontal or vertical outflow take-off. Pipework
an appropriate flexible coupling or heat shrink connections as for vertical screw details.
sleeving.
ACO HP vertical screw outlet ACO HP balcony spigot outlet ACO HP Refurbishment outlet
8
Screwed outlets are recommended where The balcony outlet provides discrete safe When an existing flat roof is being upgraded,
connection to the outlet occurs within the drainage for balconies and walkways. Supplied the refurbishment outlet is designed to fit
thickness of the slab and threaded connections complete with a ‘D’-shaped flat grating, the inside the existing outlet and pipework with
will form a completely gas-tight seal. outlet can be installed directly against a wall. minimal disruption without the need to remove
The grating is supplied with suitable apertures the original unit or pipework.
to accommodate 50mm, 75mm or 100mm
Vertical screw outlets have a female parallel
nominal bore rainwater downpipes, easily cut
thread to BS 21:1985 for connecting directly Outlets are supplied with a flexible finned pipe
on site to suit the application.
to pipes conforming to BS EN 10226:2005. seal ensuring a watertight connection to
This ensures a completely watertight seal when existing pipework. The ease of use and
screwed home into the outlet body. minimal disruption to the existing rainwater
system makes this an extremely cost effective
solution when upgrading flat roofs.
A range of ABS threaded adaptors are available
from ACO Building Drainage to allow
connection to PVC-U, socketless cast iron and
aluminium rainwater pipes.
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Technical Data
B
Membrane
D
C
E
† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).
Cast iron pipework to BS 416:1990 or Building Drainage HP vertical spigot outlets work shall be carried out strictly in
BS EN 877 :1999. with locked dome grating supplied by ACO accordance with the manufacturer’s
Building Drainage (a division of ACO instructions and the installation details are
PVC-U ‘O’-ring socketed pipe to
Technologies plc), ACO Business Centre, set out on Drawing No. *.
BS 4514:2001 (for 75HP-D, 100HP-D
Caxton Road, Bedford MK41 0LF.
and 150HP-D outlets only).
Connection to 50HP-D outlets via pipe * please delete or complete as appropriate.
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO High Performance Rainwater Outlets
A
B
Membrane
D
C
E
† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).
Cast iron pipework to BS 416:1990 or Drainage HP vertical spigot outlets with work shall be carried out strictly in
BS EN 877 :1999. locked flat grating supplied by ACO Building accordance with the manufacturer’s
Drainage (a division of ACO Technologies plc), instructions and the installation details are set
PVC-U ‘O’-ring socketed pipe to
ACO Business Centre, Caxton Road, Bedford out on Drawing No. *.
BS 4514:2001 (for 75HP-F, 100HP-F
MK41 0LF.
and 150HP-F outlets only).
Connection to 50HP-F outlets via pipe * please delete or complete as appropriate.
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Technical Data
B
Membrane
D
C
E
† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).
11
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO High Performance Rainwater Outlets
B Membrane
D
C
E
† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).
12
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Technical Data
Membrane
C
E
D
† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).
13
Cast iron pipework to BS 416:1990 or Drainage HP 45° spigot outlets with locked work shall be carried out strictly in
BS EN 877 :1999. dome grating supplied by ACO Building accordance with the manufacturer’s
Drainage (a division of ACO Technologies plc), instructions and the installation details are set
PVC-U ‘O’-ring socketed pipe to
ACO Business Centre, Caxton Road, Bedford out on Drawing No. *.
BS 4514:2001 (for 75/45HP-D, and
MK41 0LF.
100/45HP-D outlets only).
Connection to 50/45HP-D outlets via pipe * please delete or complete as appropriate.
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO High Performance Rainwater Outlets
NEW!
B Membrane
C
E
D
† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).
14
Cast iron pipework to BS 416:1990 or Drainage HP 45° spigot outlets with locked work shall be carried out strictly in
BS EN 877 :1999. flat grating supplied by ACO Building Drainage accordance with the manufacturer’s
(a division of ACO Technologies plc), instructions and the installation details are set
PVC-U ‘O’-ring socketed pipe to
ACO Business Centre, Caxton Road, Bedford out on Drawing No. *.
BS 4514:2001 (for 75/45HP-F and
MK41 0LF.
100/45HP-F outlets only).
Connection to 50/45HP-F outlets via pipe * please delete or complete as appropriate.
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Technical Data
B
Membrane
NEW!
E
D
† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).
15
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO High Performance Rainwater Outlets
B
Membrane
NEW!
E
D
† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).
16
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Technical Data
A
NEW!
B
Membrane
C
E
D
† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).
17
Cast iron pipework to BS 416:1990 or Drainage HP 90° spigot outlets with locked work shall be carried out strictly in
BS EN 877 :1999. dome grating supplied by ACO Building accordance with the manufacturer’s
Drainage (a division of ACO Technologies plc), instructions and the installation details are set
PVC-U ‘O’-ring socketed pipe to
ACO Business Centre, Caxton Road, Bedford out on Drawing No. *.
BS 4514:2001 (for 75/90HP-D and
MK41 0LF.
100/90HP-D outlets only).
Connection to 50/90HP-D outlets via pipe * please delete or complete as appropriate.
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO High Performance Rainwater Outlets
A
NEW!
B
Membrane
C
E
D
† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).
18
Cast iron pipework to BS 416:1990 or Drainage HP 90° spigot outlets with locked work shall be carried out strictly in
BS EN 877 :1999. flat grating supplied by ACO Building Drainage accordance with the manufacturer’s
(a division of ACO Technologies plc), ACO instructions and the installation details are set
PVC-U ‘O’-ring socketed pipe to
Business Centre, Caxton Road, Bedford out on Drawing No. *.
BS 4514:2001 (for 75/90HP-F and
MK41 0LF.
100/90HP-F outlets only).
Connection to 50/90HP-F outlets via pipe * please delete or complete as appropriate.
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Technical Data
A NEW!
B
Membrane
C
E
D
† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).
19
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO High Performance Rainwater Outlets
A
NEW!
B
Membrane
C
E
D
† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).
20
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Technical Data
A 230
B 160
Membrane
C
E
D
G
F
† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).
21
Cast iron pipework to BS 416:1990 or Drainage HP vertical spigot outlets with work shall be carried out strictly in
BS EN 877 :1999. locked flat grating supplied by ACO Building accordance with the manufacturer’s
Drainage (a division of ACO Technologies plc), instructions and the installation details are set
PVC-U ‘O’-ring socketed pipe to BS
ACO Business Centre, Caxton Road, Bedford out on Drawing No. *.
4514:2001 (for 75HP-BO and 100HP-BO
MK41 0LF.
outlets only).
Connection to 50HP-BO outlets via pipe * please delete or complete as appropriate.
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO High Performance Rainwater Outlets
E
Membrane
A
B
F
C
† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).
22
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Technical Data
A C
B D
Membrane
G
E
† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).
23
Cast iron pipework to BS 416:1990 or spigot outlets with locked dome grating work shall be carried out strictly in
BS EN 877 :1999. supplied by ACO Building Drainage (a division accordance with the manufacturer’s
of ACO Technologies plc), ACO Business instructions and the installation details are set
PVC-U ‘O’-ring socketed pipe to
Centre, Caxton Road, Bedford MK41 0LF. out on Drawing No. *.
BS 4514:2001.
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO High Performance Rainwater Outlets
A
B
D NEW!
Membrane
C
F
G
E
† Actual flow rate through outlets may be significantly higher but stated capacity limited to conform to BS EN 12056-3:2000 to prevent siphonic action for gravity rainwater
drainage systems.
† Flow rate measured at 35mm head of water over outlet body for outlets up to 110mm diameter and 45mm head for 160mm diameter outlets as per EN 1253-2:2015.
‡ Based on a rainfall intensity of 75mm/hr (0.02083 l/s/m²).
24
75HP-RFO : 71.5 to 78.5mm internal vertical spigot outlets with locked dome work shall be carried out strictly in
diameter. grating supplied by ACO Building Drainage accordance with the manufacturer’s
(a division of ACO Technologies plc), ACO instructions and the installation details are set
100HP-RFO : 97.0 to 104.0 mm
Business Centre, Caxton Road, Bedford out on Drawing No. *.
diameter.
MK41 0LF.
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Technical Data
NEW!
D
A*
A*
B B
105952 105953
ØC
ØC
25
Overflow modules are easily attached to an Overflow units are supplied with a PVC tube
appropriate circular 50/75HP or 100/150HP 250mm long that can be easily cut on site to
rainwater outlets in applications where grating the maximum permissible overflow height
blockage from leaves, for example, would lead required for the application. Overflow units are
to an excessive accumulation of water on the used in conjunction with an appropriate spigot
roof area. Unplanned excess water on the roof outlet unit.
area can lead to over-spill to the sides of the
building and significantly increase the load
applied to the roof structure.
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO High Performance Rainwater Outlets
A A
B
C C
105954 105955
50/75RR 100/150RR
26
A C A C
B
D E D E
105956 105957
HPBO-RR HPGO-RR
105956 HPBO-RR 50HP-BO; 75HP-BO; 100HP-BO 207 117 150 177 115 0.80
105957 HPGO-RR 75HP-GO; 100HP-GO 240 125 145 200 105 1.60
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Technical Data
150
B
Male Thread (A)
Discharge spouts provide a convenient and aesthetically pleasing finishing detail to attach to a parapet/vertical wall outlet pipe. Manufactured from
LM6 aluminium silicon alloy they can be directly connected to ACO Building Drainage ABS Threaded Adaptors with a watertight seal and secured to
the vertical wall using two fixing lugs. Discharge spout projection from the vertical wall’s: 40mm.
27
A A A
B
C C C
D D D
105962 105963 105964
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO High Performance Rainwater Outlets
Terrace grates are designed for installations with terraced paving slabs or block paviors. Terrace grates can only be used with raising rings for circular
outlets as shown on Page 26. A slotted fixing detail allows 90° rotational movement to accommodate slab/pavior patterns.
250
16
230
All dimensions in mm
Weight
Part No Product Ref Grating Size (mm)
(kg)
Deck supports are used where ACO Building Drainage HP Rainwater Outlets are installed in metal deck roof constructions, providing a stable and
secure interface between the outlet and roof. Deck Supports are manufactured from mild steel and primed in a red oxide paint finish and finished in a
polyester powder coat. They are suitable for all types of roof decking.
600
600
395
395
70
15
Ø2
Ø3
28
395 395
600 600
105966 105967
Weight
Part No Product Ref Suitable for Outlet Product Ref
(kg)
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Technical Data
ACO Building Drainage cast iron Car Park Key benefits Key features
Gullies are designed specifically for trafficked
Durable, robust cast iron construction Stainless steel bolted grating for security
car park applications with direct vehicle
access providing a robust, compact and Low profile design for shallow deck 110mm spigot outlet for easy pipe
Car Park gullies are ideal for multi-storey car Load Class M125 (12.5 tonne) grating to Removable galvanised steel dirt bucket
parks, shallow parking deck or podium deck BS EN 1253 Optional drainage weep hole facility
applications and particularly suited for high Locked grating Optional intumescent fire stop cartridge
traffic frequency. High flow rate – large area drainage R120/2 hour rating (vertical outlet
Easy maintenance versions only) 29
Shallow deck installation with 110mm Through deck installation with 110mm vertical
horizontal outlet with weep-hole drainage outlet complete with locked grating, galvanised
facility. Complete with locked grating and steel dirt bucket and R120/2 hour fire stop
galvanised steel dirt bucket. cartridge fitted.
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO Car Park Gullies
300
300
110
Ø110 16
300
All dimensions in mm
Spigot Dia Flow Rate† Area Drained‡ Flanged & Galvanised Weight
Part No Load Class Grating Locks
(mm) (l/s) (m²) Weep Holes Dirt Bucket (kg)
450
300
300
110
30
Ø110
16
300
450
All dimensions in mm
Spigot Dia Flow Rate† Area Drained‡ Flanged & Galvanised Weight
Part No Load Class Grating Locks
(mm) (l/s) (m²) Weep Holes Dirt Bucket (kg)
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Technical Data
300
180
3°
Ø110
16
339 300
All dimensions in mm
Spigot Dia Flow Rate† Area Drained‡ Flanged & Galvanised Weight
Part No Load Class Grating Locks
(mm) (l/s) (m²) Weep Holes Dirt Bucket (kg)
ACO Car Park Gully - Horizontal Outlet, Flanged Weep Hole NEW!
50
450
300
180
3°
Ø110
31
339
16
300
450
All dimensions in mm
Spigot Dia Flow Rate† Area Drained‡ Flanged & Galvanised Weight
Part No Load Class Grating Locks
(mm) (l/s) (m²) Weep Holes Dirt Bucket (kg)
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO Car Park Gullies - Accessories
Accessories
NEW!
Raising Ring 45mm
45
30
300
300
All dimensions in mm
Raising rings are suitable for all ACO Building Drainage Car Park Gullies and may be cascaded in increments of 45mm. Extension bolts for grating
locks not provided. M12 x 35mm stainless steel cap head screws supplied as standard.
All dimensions in mm
32
Part No Fire Rating Weight (kg)
Intumescent fire stop can only be used with vertical outlet Car Park Gullies. Please note that the Car Park gully flow rate is restricted to 3 l/s when a
fire stop is fitted (144m² area drained at a rainfall intensity of 75mm/hr (0.02083 l/s/m²).
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Installation Recommendations
Warm Roof
Raising Ring
A warm roof is where the main mass of the
Two Layer mastic Ashpalt
roof structure lies below the main thermal
Reflective Layer Secure Bolted Grating
insulation. The waterproof membrane is of Chippings
Clamping Ring
positioned above the insulation.
Vapour Barrier
Structural Deck
Outlet Body
Raising Ring
Un-insulated Roof
Clamping Ring
Outlet Body
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO High Performance Rainwater Outlets
HP 90° outlet Three Layer Built up Felt Roof Secure Bolted Grating
Clamping Ring
Firring Piece
Plywood Deck
Timber Joist
Insulation
Plywood Base
Insulated Gutter
Rigid Insulation Board
Ply Sub-base
Timber Spacers in
Insulated Gutter
34 Outlet Body
Refurbishment outlet
Main Waterproofing
ACO HP Refurbishment Outlet
(Fitted as Manufacturers Recommendations)
Refurbishment Insululation
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Installation Recommendations
RWP
Structural Deck
Outlet Body
Two-way outlet
Vapour Barrier
35
Structural Deck
Clamping Ring
Spout
Vapour Barrier
Structural Deck
Hopper & RWP
(by others)
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
ACO High Performance Rainwater Outlets
Terrace grate
Structural Deck
Metal Deck
Deck Support
Outlet Body
Contact the ACO Building Drainage Team on 01462 810400 or email [email protected] for further details.
Appendices
Step 1 Step 2
Remove redundant roofing materials; brush & clean surfaces ready for Lay new vapour barrier & bond into existing rainwater outlet.
new installation.
Step 3 Step 4
With the finned rubber seal removed, insert the ACO Refurbishment Bond strips of vapour barrier to the Refurbishment Outlet flanges and
Outlet into the sump of the existing rainwater outlet body. If necessary, existing vapour barrier to ensure a total seal.
reduce the spigot length of the new outlet to allow full insertion.
Replace rubber seal and re-insert. 37
ACO Engineered Solutions offer the designer / specifier a Examples of ACO Engineered Solution applications include:
range of products virtually free from the constraints of ‘off ∙ Workable drainage where there is limited invert depths
the shelf’ items. Our engineers are able to offer detailed
∙ Refurbishment situations with replacement channels and
advice on all aspects of required design solutions, together
point drainage
with hydraulic flow analysis, practical site installation,
suitable materials and best practices. ACO Engineered ∙ Interface with threshold details
Solutions enjoy rigorous product management from initial ∙ Discreet channel applications
enquiry through to post-delivery. ∙ Radius channel applications
ACO FreeDeck
38
All product brochures are available for viewing and downloading at www.acobd.co.uk
Associated ACO Building Drainage Product Ranges
ACO PIPE®
maintenance. When used with ACO stainless steel gullies and channel systems
it provides a unique system for building drainage.
ACO Modular 125 Stainless Steel linear drainage is our most requested product
range as it is suitable for most applications. ACO Modular 125 is manufactured in
stainless steel grade 304 as standard and 316 to order. Available in a wide range of
lengths, constant depths, sloping inverts and gratings ‘off the shelf’, it can be
modified to meet your exact application requirements. Used together with ACO Gully 39
®
157 or 218 and ACO PIPE it offers the specifier, contractor and user the benefits of
a unified system for building drainage and one stop drainage solution with unique
advantages – fully tested and classified to BS EN 1433, CE marked, pickle Product catalogue
channel for enhanced flow efficiency, optional grating security locks and lightweight
channel sections for safe and easy installation.
ACO Technologies plc
ACO Sport
ACO Wildlife
e-mail: [email protected]
www.acobd.co.uk
© April 2015 ACO Technologies plc. All reasonable care has been taken in compiling the information in this document. All
recommendations and suggestions on the use of ACO products are made without guarantee since the conditions of use are beyond
the control of the Company. It is the customer's responsibility to ensure that each product is fit for its intended purpose, and that the
actual conditions of use are suitable. This brochure and any advice is provided by ACO Technologies plc (the Company) free of
charge and accordingly on terms that no liability including liability for negligence will attach to the Company or its servants or
agents arising out of or in connection with or in relation to this brochure or any such advice. Any goods supplied by the Company
will be supplied solely upon its standard conditions of sale, copies of which are available on request. The Company's policy of
continuous product development and improvement renders specifications liable to modification. Information provided in this
brochure is therefore subject to change without prior notification.