0% found this document useful (0 votes)
41 views4 pages

7SD522 Ordering

This document provides selection and ordering information for the 7SD5 line differential protection relay from Siemens. The 7SD5 offers two-terminal and multi-terminal differential protection with optional distance protection. It has configurable current and voltage inputs, auxiliary power options, and housing variations. The relay provides various digital and analog inputs and outputs and can be ordered with different language and regional settings.

Uploaded by

mahesh reddy m
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
41 views4 pages

7SD522 Ordering

This document provides selection and ordering information for the 7SD5 line differential protection relay from Siemens. The 7SD5 offers two-terminal and multi-terminal differential protection with optional distance protection. It has configurable current and voltage inputs, auxiliary power options, and housing variations. The relay provides various digital and analog inputs and outputs and can be ordered with different language and regional settings.

Uploaded by

mahesh reddy m
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Line Differential Protection / 7SD52/53

Selection and ordering data

Description Order No. Short code


7SD5 combined multi-end line differential protection with distance protection

Device type1)
7SD5 - - -
1
Two-terminal differential relay with 4-line display 2 2
Two-terminal differential relay with grapical display 3 2
Multi-terminal differential relay with 4-line display
Multi-terminal differential relay with graphical display
2 3
see next page
2
3 3

Measurement input
Iph = 1 A2), Ie = 1 A2)
Iph = 1 A2), Ie = high (min. = 0.005 A)
1
2
3
Iph = 5 A2), Ie = 5 A2) 5
Iph = 5 A2), Ie = sensitive (min. = 0.005 A) 6

Auxiliary voltage (Power supply, BI trigger level) 4


24 to 48 V DC, trigger level binary input 19 V4) 2
60 to 125 V DC3), trigger level binary input 19 V4) 4
110 to 250 V DC3), 115 V AC, trigger level binary input 88 V4)
220 to 250 V DC3), 115 V AC, trigger level binary input 176 V4)
5
6
5
Binary/ Signal/ Fast High- Housing Flush- Flush- Surface-
indication command relay5) speed width mounting mounting mounting
inputs outputs incl.
live status
trip
output6)
referred
to 19”
housing/
screw-type
housing/
plug-in
housing/
screw-type 6
contact terminals terminals terminals

8 4 12 – ½ „ A
8
8
4
4
12
12


½
½ „
„ E
J
7
16 12 12 – „ C
16 12 12 – „ G
16 12 12 – „ L 8
16 4 15 5 „ N
16 4 15 5 „ Q
16 4 15 5 „ S
24 20 12 – „ D 9
24 20 12 – „ H
24 20 12 – „ M
„
24
24
12
12
15
15
5
5 „
P
R 10
24 12 15 5 „ T
24 4 18 10 „ W

Region-specific default / language settings and function versions 11


Region GE, German language (can be changed) A
Region world, English language (can be changed) B
Region US, US-English language (can be changed) C
Region world, French language (can be changed) D 12
Region world, Spanish language (can be changed) E
Region world, Italian language (can be changed) F

13
1) Redundant prot. data interface for Hot-Standby-service is possible 4) The binary input thresholds are selectable in three steps by means
with a two terminal differential relay (second prot. data interface is
needed)
of jumpers.
5) Fast relays are indentified in the terminal diagram. The time
14
2) Rated current 1/5 A can be selected by the means of jumpers. advantage compared to signal/command outputs is approx. 3 ms,
3) Transition between three auxiliary voltage ranges can be selected mainly for protection commands
by means of jumpers. 6) High-speed trip outputs are identified in the in the terminal dia-
gram. The time advantage compared to fast relays is approx. 5 ms 15
Siemens SIP · Edition No. 8 7/47
Line Differential Protection / 7SD52/53
Selection and ordering data

Description Order No. Short code

1 7SD5 combined multi-end line differential protection with distance protection

System interfaces
7SD52 - - -

No system interface 0
IEC protocol, electrical RS232 1
2 IEC protocol, electrical RS485
IEC protocol, optical 820 nm, ST-plug
2
see next
page
3

Further protocols see supplement L 9 L 0

3 PROFIBUS DP slave, RS485 A


PROFIBUS DP slave, optical 820 nm, double ring, ST connector 1) B
DNP 3.0, RS485 G

4 DNP 3.0, optical 820 nm, ST connector 1)


IEC 61850, 100 Mbit Etherrnet, electrical, double, RJ45 connector (EN100)
H
R
IEC 61850, 100 Mbit Ethernet, with integrated switch, optical, double, LC-connector (EN100) 2) S

DIGSI / Modem interface (on rear of device) and protection interface 1


5 See additional indication M 9 M

DIGSI / Modem interface (on rear of device)


Without DIGSI-interface on rear 0
6 DIGSI 4, electric RS232
DIGSI 4, electric RS485
1
2
DIGSI 4, optical 820 nm, ST plug 3

7 Protection data interface 1


FO5: Optical 820 nm, 2 ST-plugs, line length up to 1.5 km
via multimode FO cable for communication converter or direct FO connection 3) A
FO6: Optical 820 nm, 2 ST-plugs, line length up to 3.5 km
via multimode FO cable for direct FO connection
8 FO17: Optical 1300 nm, LC-Duplex-plugs, line length up to 24 km
B

via monomode FO cable for direct FO connection 4) G


FO18: Optical 1300 nm, LC-Duplex-plugs, line length up to 60 km
via monomode FO cable for direct FO connection 4) 5) H
9 FO19: Optical 1550 nm, LC-Duplex-plugs, line length up to 100 km
via monomode FO cable for direct FO connection 4) 6) J
FO30: Optical 820 nm, 2 ST-plugs, line length up to 1.5 km
via multimode FO cable for communication networks with
IEEE C37.94 interface or direct FO connection 7)
10 S

11

12

13 1) Not possible for surface mounting housing (Order No. pos. 5) For distances less than 25 km a set of optical attenuators
9 = E/G/H/Q/R). For the surface mounted version, please order 7XV5107-0AA00 must be installed to avoid saturation of the
a device with the appropriate electrical RS485 interface and an receiver element
external FO-converter 6) For distances less than 50 km a set of optical attenuators
14 2) Not possible for surface mounting housing (Order No. pos.
9 = E/G/H/Q/R) please order the relay with electrical interface and
7XV5107-0AA00 must be installed to avoid saturation of the
receiver element
use a separate fiber-optic switch. 7) Only available in flush-mounting housing (Order No. pos.
3) Communication converter 7XV5662, see Accessories. 9 ≠ E/G/H/Q/R).

15 4) Device for surface mounting housing (Order No. pos. 9 = E/G/H/Q/R)


will be delivered with external repeater 7XV5461-0Bx00.

7/48 Siemens SIP · Edition No. 8


Line Differential Protection / 7SD52/53
Selection and ordering data

Description Order No. Short code


7SD5 combined multi-end line differential protection with distance protection

Functions 1 / Protection interface 2


7SD52 - - -
1
Trip mode Auto-reclosure (ANSI 79) Synchro-check (ANSI 25)
3-pole without without
3-pole with without
0 see next
1 page 2
1-/3-pole without without 2
1-/3-pole with without 3
3-pole
3-pole
without
with
with
with
4
5
3
1-/3-pole without with 6
1-/3-pole with with 7

Functions 1 and Protection interface 2 6) 9 N 4


Functions 1
Trip mode Auto-reclosure (ANSI 79) Synchro-check (ANSI 25)
3-pole
3-pole
without
with
without
without
0
1
5
1-/3-pole without without 2
1-/3-pole with without 3
3-pole without with 4 6
3-pole with with 5
1-/3-pole without with 6
1-/3-pole with with 7

Protection interface 2
7
FO5: Optical 820 nm, 2 ST-plugs, line length up to 1.5 km
via multimode FO cable for communication converter or direct FO connection 1) A
FO6: Optical 820 nm, 2 ST-plugs, line length up to 3.5 km
via multimode FO cable for direct FO connection B 8
FO17: Optical 1300 nm, LC-Duplex-plugs, line length up to 24 km
via monomode FO cable for direct FO connection 2) G
FO18: Optical 1300 nm, LC-Duplex-plugs, line length up to 60 km
via monomode FO cable for direct FO connection 2) 3) H 9
FO19: Optical 1550 nm, LC-Duplex-plugs, line length up to 100 km
via monomode FO cable for direct FO connection 2) 4) J
FO30: Optical 820 nm, 2 ST-plugs, line length up to 1.5 km
via multimode FO cable for communication networks with
IEEE C37.94 interface or direct FO connection 5) S
10

11

12

13
1) Communication converter 7XV5662, see Accessories. 4) For distances less than 50 km a set of optical attenuators
2) Device for surface mounting housing (Order No. pos. 9 = E/G/H/Q/R) 7XV5107-0AA00 must be installed to avoid saturation of the
receiver element.
14
will be delivered with external repeater 7XV5461-0Bx00.
3) For distances less than 25 km a set of optical attenuators 5) Only available in flush-mounting housing (Order No. pos. 9 ≠
7XV5107-0AA00 must be installed to avoid saturation of the E/G/H/Q/R).
receiver element. 6) In a two terminal differential relay the protection interface 2 can
be used as redundant protection interface (Hot Standby). 15
Siemens SIP · Edition No. 8 7/49
Line Differential Protection / 7SD52/53
Selection and ordering data

Description Order No. Short code

1 7SD5 combined multi-end line differential protection with distance protection

Functions
7SD52 - - -

Time overcurrent pro- Ground fault Distance protection Distance protection (Ipick- Ground fault
tection/ Breaker failure protection (Pickup Z<, polygon, upI>,-VI/φ, -Z<), polygon, detection
2 protection (ANSI 50,
50N, 51, 51N, 50BF)
(ANSI 67N) MHO, parallel line
comp.) Power swing
parallel line comp. 2),
power swing det. (ANSI
for isolated/
compensated
detection (ANSI 21, 21, 21N, 68, 68T) networks 1)
21N, 68, 68T)
with without without without without
3 with without without with without
C
D
with without with without without E
with with without without without F

4 with
with
with
with
without
with
with
without
without
without
G
H
with without without without with J
with without without with with K

5 with
with
with
with
without
without
without
with
with
with
L
M

Additional functions 1
6 4 Remote commands/
24 Remote indications
Transformer
expansions
Fault locator Voltage protection,
frequence protection
Restricted ground
fault low impedance
(ANSI 27, 50) (ANSI 87N) 2)
with without 1-side measuring without without J

7 with
with
without
without
1-side measuring
2-side measuring
with
without
without
without
K
L
with without 2-side measuring with without M
with with 1-side measuring without without N
8 with with 1-side measuring with without P
with with 2-side measuring without without Q
with with 2-side measuring with without R
with with 1-side measuring without with S
9 with with 1-side measuring with with T
with with 2-side measuring without with U
with with 2-side measuring with with V

10 Additional functions 2
Measured values, External GPS Capacitive current
extended, synchronization load compensation
11 Min/Max values
without without without 0
without with without 1
with without without 2
12 with
without
with
without
without
with
3
4
without with with 5
with without with 6
13 with with with 7

14

15 1) Only available with Order No. Pos. 7 = 2 or 6


2) Only available with Order No. Pos. 7 = 1 or 5

7/50 Siemens SIP · Edition No. 8