Additional Instructions Intelligent Cleaning
About these Instructions These instructions are supplementary to the superordinate operating
instructions for the cleaning unit RS wash (D wash, P wash, SHERAprint
wash, 3Dewash). These instructions only describe the operation of the
machine with the ‘Intelligent Cleaning’ function and therefore do not
claim to be complete.
For general safety information and instructions on operating the
machine, please refer to the separate operating instructions of the
RS wash (D wash, P wash, SHERAprint wash, 3Dewash). →
The supplementary instructions are part of the product and must be
kept in its immediate vicinity and accessible to personnel at all times.
The personnel must have carefully read and understood these
instructions before starting any work. The basic prerequisite for safe
working is compliance with all the safety notes and handling
instructions given in these instructions.
In addition, the local occupational health and safety regulations and
general safety regulations for the area of application of the machine
apply.
Passing on and copying of this document, utilization and
communication of its contents are prohibited unless expressly
permitted. Violations will result in liability for damages.
Changes may have been made to the product after this
documentation’s publication date. We expressly reserve the right to
make any changes to the product.
The original instructions were written in German.
Our general terms and conditions apply.
© All rights reserved by Rapid Shape GmbH.
Table of Contents
Show saturation info at… To keep an overview of the saturation of your cleaning liquid, you can
set from which degree of saturation the saturation of each cleaning
bottle is displayed before each cleaning process:
1. Check the ‘Show saturation info at‘ box.
2. Set from which degree of saturation the saturation of each bottle
should be displayed automatically. To do this, press the arrow
buttons to set the percentage value. (By default, the degree of
saturation is displayed at 75%.)
At a lower saturation value, the saturation display will be shown
earlier than at a higher value.
Allow the use of cleaning liquid If the cleaning liquid reaches a saturation of 100%, it must be checked
with 100% saturation… whether the liquid can still absorb material or whether it must be
replaced. You can allow or prohibit the use of cleaning liquid with a
saturation of 100%:
1. Check the ‘Allow the use of cleaning liquid with 100%
saturation‘ box if you want to allow the use of cleaning liquid
with a saturation of 100%.
In this case, you can continue cleaning with a liquid which has a
degree of saturation of over 100%. However, to do so, you must
confirm that the cleaning liquid is OK and that it can still absorb
material.
2. Do not check the box if you generally do not want to allow the
use of cleaning liquid with a saturation of 100%.
3. Make the settings for the cleanliness grade. → Chapter 2.2.2
Allow the use of cleaning liquid To allow cleaning with a cleaning liquid of a lower cleanliness grade,
with lower cleanliness grade… please proceed as follows:
1. Check the ‘Allow the use of cleaning liquid with lower
cleanliness grade’ box.
Allow mixing of materials… To allow mixing of materials (and cleaning liquids), please proceed as
follows:
1. Check the ‘Allow mixing of materials‘ box.
2. Press the ‘Return ‘ button and then the ’Home ’ button to
return to the operator interface.
N O TE !
Wearing protective gloves protects the skin from contact
with skin damaging materials. During work steps in
which you work with printing materials, we therefore
always recommend the wearing of protective gloves.
Figure 10: Lift the upper part Figure 11: Lift off the upper part
8. Take two bottles of cleaning liquid and twist off the lids.
Place the lids in the storage inserts provided for this purpose in
the lower part of the container.
9. Place the opened bottles in the round openings of the lower part
of the container. Make sure that the position markings on the
bottles point to the markings in the lower part of the container.
These markings ensure that the bottles are correctly positioned
so that the RFID tags located on the bottles can be read by the
RFID reader.
10. Take the upper part of the container and insert the tube ends
into the bottles. Close the container.
Make sure that the container is not moved jerkily. The RFID tags
on the bottles could rotate away from the reader.
11. Connect the container to the machine. → Chapter 3.2
Figure 13: Insert the bottles Figure 14: Close the container
4.3 Specify the Cleaning Liquid Type before Start of the Cleaning
Process
For writing the ‘Cleaning Liquid Type’ on empty RFID tags, please
proceed as follows:
1. Prerequisite: At least one empty RFID tag (‘Empty TAG’) has
been detected. (→ Chapter 4.2)
2. Press the ‘Create Tag ’ button. The ‘Empty RFID-TAG(S)
detected’ display will be displayed.
3. Open the drop-down list at the position where ‘Empty TAG’ is
displayed.
4. In the drop-down list, select the cleaning liquid that is in the
respective cleaning bottle.
5. Now press the respective ‘Create Tag ’ button to write the
selected cleaning liquid on the empty tag.
6. Press the ‘Return ‘ button to return to the operator interface.
The RFID tags will be automatically read out again and the
‘Cleaning Liquid Type’ will now be displayed.
Figure 21: ‘Intelligent Cleaning Info‘, saturated cleaning bottle on the Pre-
Cleaning position (rear)
To reset the bottle status after a bottle refill, please proceed as follows:
1. Prerequisite: At least one bottle has been refilled with fresh
cleaning liquid. The container is connected to the machine.
(→ Chapter 4.4.2)
2. Call up the ‘Cleaning Liquid Info ’ menu.
3. Press the ‘Refill ‘ button. The ‘Intelligent Cleaning Refill’
display will be opened.
4. Press the respective ‘Create Tag ’ button to reset the
corresponding cleaning bottle.
Once the bottle status has been reset, the ‘Cleaning Grade’ will
be displayed with the value ‘0’. The bar display of the saturation
will also be reset.
5. Afterwards, press the ‘Return ‘ button to return to the
‘Cleaning Liquid Info’ menu.
Figure 22: ‘Intelligent Cleaning Refill‘, status of the Pre-Cleaning bottle not
reset after refill
6 Troubleshooting
Possible Causes The RFID tags cannot be read in. At least one cleaning bottle is missing
or at least one cleaning bottle is incorrectly positioned.
Further Procedure To close the warning note and resume the cleaning process, please
proceed as follows:
1. Check at which position (Pre- & Final Cleaning) the RFID tag
has not been detected. (‘No Tag‘)
2. Press the quick coupling on the cleaning liquid container while
pulling the container from the machine.
Cleaning liquid containers, that have cutouts in the housing in
the area of the cleaning bottles, do not have to be disconnected
from the machine for repositioning of the bottles. In this case,
the bottles can be rotated through the cutouts. After having
rotated the bottles, continue with step 6.
3. Open the cleaning liquid container. → Chapter 3.1
4. Correct the positioning of the bottles which were not detected
and then carefully close the container.
5. Reconnect the container to the machine. → Chapter 3.2
6. Now press the ‘Retry ’ button to perform a new reading of the
RFID tags. Provided that both tags could now be read, the
display will ask whether the cleaning liquid container is
connected to the machine. Check that the container is
connected correctly and confirm this with the ‘Confirm ’
button. The cleaning process will then be started.
Possible Causes You are about to clean a material with a cleaning liquid which,
however, has already been used previously for cleaning a different
material. Mixing of materials is not allowed in the ‘Cleanliness Grade
Settings’. → Chapter 2.2.2
Further Procedure To close the warning note and resume the cleaning process, please
proceed as follows:
1. Check at which position (Pre- & Final Cleaning) there is a
discrepancy between ‘Printed part material’ and the material
previously cleaned with the cleaning liquid .
2. Cancel the process by pressing the ‘Cancel ’ button.
You will automatically return to the operator interface.
3. Replace the respective bottles either with new bottles or replace
them with cleaning bottles which are already written with the
respective printing material.
4. Start the cleaning process again by pressing the ‘Start ’
button.
Possible Causes You are about to clean a material with a cleaning liquid which is not
intended for cleaning this material. Mixing of materials is not allowed
in the ‘Cleanliness Grade Settings’. → Chapter 2.2.2
Further Procedure To close the warning note and resume the cleaning process, please
proceed as follows:
1. Check at which position (Pre- & Final Cleaning) there is a
discrepancy between ‘Printed part requires’ and the cleaning
liquid in the bottles .
2. Cancel the process by pressing the ‘Cancel ’ button.
You will automatically return to the operator interface.
3. Replace the respective bottles with cleaning bottles filled with the
respective cleaning liquid.
4. Start the cleaning process again by pressing the ‘Start ’
button.
Possible Causes When checking the bottle status, at least one empty RFID tag has been
detected. → Chapter 4.2
Further Procedure To write information on the empty RFID tag, please proceed as follows:
1. Check at which position (Pre- & Final Cleaning) the RFID tag
has not been detected. (‘Empty Tag‘)
2. Open the drop-down list and select the cleaning liquid that is in
the respective cleaning bottle.
3. Now press the respective ‘Create Tag ’ button to write the
selected cleaning liquid on the empty tag.
4. Press the ‘Return ‘ button and then the ’Home ’ button to
return to the operator interface.
Possible Causes You are about to clean a material with a cleaning liquid of a lower
(purer) cleanliness grade than the material to be cleaned itself.
Cleaning materials with a cleaning liquid of a lower cleanliness grade
is allowed in the ‘Cleanliness Grade Settings’. → Chapter 2.2.2
Further Procedure To close the warning note and resume the cleaning process, please
proceed as follows:
1. Check at which position (Pre- & Final Cleaning) there is a
discrepancy between the cleanliness grade of the ‘Printed Part’
and the cleanliness grade of the cleaning liquid .
2. Cancel the process by pressing the ‘Cancel ’ button.
You will automatically return to the operator interface.
3. Replace the respective bottles with cleaning bottles which are
already written with the respective cleanliness grade.
4. Start the cleaning process again by pressing the ‘Start ’
button.
Figure 29: Warning note ’Cleanliness grade of cleaning liquid is lower than
printed part‘
Possible Causes You are about to clean a material with a cleaning liquid which has a
higher (dirtier) cleanliness grade than the material to be cleaned. It is
not possible to clean materials with a cleaning liquid which has a
higher cleanliness grade than the material to be cleaned, otherwise the
part will become contaminated.
Further Procedure To close the warning note and resume the cleaning process, please
proceed as follows:
1. Check at which position (Pre- & Final Cleaning) there is a
discrepancy between the cleanliness grade of the ‘Printed
Part‘ and the cleanliness grade of the cleaning liquid .
2. Cancel the process by pressing the ‘Cancel ’ button.
You will automatically return to the operator interface.
3. Replace the respective bottles either with new bottles or replace
them with cleaning bottles which are already written with the
respective cleanliness grade.
4. Start the cleaning process again by pressing the ‘Start ’
button.
Figure 30: Note ’Bottle in position one has an unexpected bottle type‘
Further Procedure To close the note and resume the cleaning process, please proceed as
follows:
1. Press the ‘Confirm ’ button to change the Final Cleaning
bottle in the Pre-Cleaning position to a Pre-Cleaning bottle.
The cleaning process will then be started afterwards.
Figure 31: Note ’Bottle in position two has an unexpected bottle type‘
Further Procedure To close the note and resume the cleaning process, please proceed as
follows:
1. Cancel the process by pressing the ‘Cancel ’ button.
You will automatically return to the operator interface.
2. Insert a new Final Cleaning bottle.
3. Start the cleaning process again by pressing the ‘Start ’
button.
Possible Causes At least one cleaning liquid has reached the set degree of saturation
in the ‘Saturation Settings’. (‚Show saturation info at‘ → Chapter 2.2.1)
Further Procedure To close the note and resume the cleaning process, please proceed as
follows:
1. Check which cleaning liquid will soon be saturated .
2. Press the ‘Confirm ’ button to confirm that you have read the
note. The cleaning process will then be started.