DPM Question
DPM Question
2 Which one of mentioned three degrees of freedom does not depend on the input of a position reference
system.
A Surge
B Sway
C Yaw
4 Most modern DP systems have a built in Trainer. What would be one of the requirements to enter the
Trainer mode?
A Ensure DP is in control of the thrusters
B Ensure DP system is in Stand By Mode
C Ensure a DP system is in active control of vessel positioning
8 Explain the effects if a thruster drive fails such that thruster output falls to 50% of commanded output
on a thruster that is pushing the vessel to STBD (assume that this DP system does not use RPM
feedback for control purposes)
A Initially the vessel will move off location to PORT. The resulting position deviation causes the
control system to correct the error by pushing harder with the remaining thrusters to STBD. After a
few minutes the DP system will calculate an increased force from STBD.
B Initially the vessel will move off location to PORT. The resulting position deviation causes the
control system to correct the error by pushing harder with the remaining thrusters to STBD. After a
few minutes the DP system will calculate an increased current from PORT.
C No effect, the DP system control will increase the other thrusters to compensate. No errors will be
introduced. The calculated force will remain unchanged.
9 Which of the following statements is most true about a controllable pitch fixed RPM thruster driven by
electrical motor?
A Starting currents are very high, power consumption is about 25% at zero thrust, and certain types of
control failures may cause the thruster to run at 100%.
B Starting currents are minimal, power consumption is about zero at zero thrust, and almost all control
failures cause the thruster to shut down.
C Starting currents usually require an extra engine on-line, power consumption is constant regardless of
RPM, and all failure modes shut down the thruster.
13 If one thruster that is running 45% suddenly starts showing 20% feedback, what is the fastest method
to troubleshoot it from DP?
A Watch positioning ability carefully and observe calculated force while alternately enabling and
disabling the thruster.
B Compare the thruster’s load readings with other thrusters running at similar RPM.
C You cannot troubleshoot thruster feedback from DP, call the technician.
16 Is it acceptable to replace the faulty network switch by the switch from other manufacturer to keep the
vessel redundancy?
A Yes, it is possible to replace faulty network switch by any other network switch from different
manufacturer.
B No, we have to order & wait for the spare network switch from DP installation manufacturer.
C Yes, if network switch from other manufacturer has the same characteristics (same used LAN port
quantity, not less).