Foundation Drawing - 25M Mast

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

FOUNDATION LOADING AT BASE OF MAST

3500 WIND SPEED (M/S) 50


VERTICAL LOAD (KN) -
1100 BAR B1

1100
3500

DETAIL OF PADASTAL NOTES:-1) Reinforcement shown in drawing is for illustration only.


refer reinforcement table for actual qty
2) Concrete GRADE M25
3) Clear cover 50 mm
4) Steel : Fe-500
5)This drawing only for reference for actual prcatice discus with
TEMPLATE civil engineer as per your land and geographic condition.
FOUNDATION BOLTS 750mm, PCD:- 650 SCHEDULE OF REINFORCEMENT
M30X1000, 12 NOS
BAR DIA. SHAPE NOS LENGTH
1100
100

ANCHOR PLATE
300

750mm, PCD:- 650mm B1 16 24 3420


G.L. G.L.
75 MM CONDUIT PIPE
FOR CABLE ENTRY
B2 12 48 3900

BAR B1
2800

BAR B3 8
STIRRUPS OF 200 C/C B3 8 16 4100
BAR B4
8@75 C/C BOTH WAYS
B4 8 92 3900
BAR B2
400
500

12 @150 C/C BOTH WAYS OFFER NO :


DRAWN
PCC (1:4:8) CHK'D
APPV'D
3400
100

3500 MATERIAL: M.S. PRODUCT CODE : JTE-DFD-25M


3750
FINISH: DISCRIPTION : DETAIL FOUNDATION DRAWING FOR 25M MAST

QUANTITY : ALL THE DIMENSIONS ARE IN MM.

You might also like