Premierflex 3000
Premierflex 3000
Premierflex 3000
BITUMAT PREMIERFLEX-3000 is available in two For details of installation methods and flashing
basic finishes: requirements, consult the relevant BITUMAT
• Black smooth finish with polyethylene Systems Design and Installation Manual.
surfaces for covered applications.
• Granule surfacing for exposed
applications.
PREMIERFLEX-3000
SBS Modified Waterproofing Membrane
TECHNICAL DATA
Property Typical Value Test Method
1. Softening point, °C 115 ASTM D 36
2. Penetration, @ 25 °C dmm 30 ASTM D 5
3. Low temperature flexibility, °C -15 to -18 ASTM D 5147
4. Heat resistance, Compound stability
@ 102 °C for 2 hours & 15 minutes No flow - Pass ASTM D 5147
5. Tensile strength, N/5 cm @ 23+2 °C
Longitudinal 800 (16 KN/m) ASTM D 5147
Transverse 600 (12 KN/m)
6. Tensile strength, N/5 cm @ -18+2 °C
Longitudinal 1000 (20 KN/m) ASTM D 5147
Transverse 750 (12.5 KN/m)
7. Elongation, % @ 23+2 °C
Longitudinal 40 ASTM D 5147
Transverse 45
8. Elongation, % @ -18+2 °C
Longitudinal 25 ASTM D 5147
Transverse 25
9. Load strain product @ 23+2 °C
Longitudinal 32,000 CGSB-37-GP-56M
Transverse 27,500
10. Load strain product @ -18+2 °C
Longitudinal 25,000 CGSB-37-GP-56M
Transverse 18,750
11. Lap joint strength, N/5 cm @ 25+2 °C
Same as membrane CGSB-37-GP-56M
Longitudinal
Transverse UEAtc
12. Tear resistance, N @ 23+2 °C
Longitudinal 400 ASTM D 5147
Transverse 400
13. Puncture resistance, N @ 25+2 °C 950 ASTM E 154,
Static indentation L3 UEAtc 5.1.9.
Dynamic indentation I3 UEAtc 5.1.10
14. Water absorption, % Wt @ 23°C / 24 hrs. <0.25 ASTM D 5147
15. Water vapour transmission, <0.30 ASTM E 96 procedure
g/m2/24 hrs. E 37.8 °C at 90% RH
16. Dimensional stability, %
Longitudinal + 0.5 ASTM D 5147
Transverse + 0.5
17. Resistance to leakage at joints Pass UEAtc
18. Resistance to aging & U.V. No change greater than ASTM
20% of the original G53
values UNI 8202
The information given in this Technical Data Sheet reflects typical median properties based on laboratory test, and practical experience; subject
to the tolerance levels of UEAtc directives. However, as the product is often used under conditions beyond our control, we can’t warrant but the
product itself.
THIS PUBLICATION AUTOMATICALLY SUPERSEDES ALL PREVIOUS PUBLICATIONS RELATING TO THIS PRODUCT.
MSD O9/2003