Carrier-Ducted-Brochure-QSM QSH v3 LR

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

INCLUDES

PARTS & LABOUR

Carrier
Inverter Ducted
Air Conditioners
About Carrier Inverter Ducted
Air Conditioners

Ducted Air Conditioning consists of an indoor and


outdoor unit. The indoor unit is concealed in the
roof with ducts around the home distributing the
air. The outdoor unit is situated outside of the
home.

Who is Carrier Air Conditioners?

Founded by the inventor of modern air conditioning


Willis Carrier, Carrier is one of the world’s leaders
in high technology heating, air conditioning and
refrigeration solutions. Carrier provides sustainable
solutions, integrating energy efficient products,
building controls and energy services for residential,
commercial, retail, transport and food services
customers. Carrier improves the world around us
through engineered innovation and environmental
stewardship. Carrier is also a leading provider to the
aerospace and building systems industries.

In 1902, Willis Carrier solved one of mankind’s


most elusive challenges by controlling the indoor
environment through modern air conditioning. His
invention enabled countless industries, promoting
global productivity, health and personal comfort.
Products

Slim Line Ducted – QSM Series


Slim line ducted provide solution in light commercial
applications and are ideal for hotels, offices and
apartments.

Compact design to fit into most ceiling space

Static pressure of upto 160Pa

Constant air volume technology for optimal


airflow

New eccentric fan design for improved


performance

Easy to install and maintain

7 year warranty

Drain pump included

Constant Air Volume Control


With the constant air volume control technology
the duct will automatically adjust to perfect
static pressure and keep a constant air volume.

Air Volume

Lack Perfect Over

Air Volume

Lack Perfect Over

Air Volume

Lack Perfect Over


Products

High Static Pressure – QSH series


High static ducted are ideal for residential applications,
where ducts run to numerous outlets.

Concealed installation

Static pressure of 200Pa

Long ducted connection

Constant air volume technology for optimal


airflow

Quiet operation

Easy to install and maintain

7 year warranty

Drain pump optional

Easy Maintenance
The unit can be serviced from both top and
bottom. And with QSH170, the splitabble design
allows the fan part and the coil part to be carried
into or out of the ceiling, for the ease of renovation
or retrofit installation or service.

Model: 42QSH170D8S
High Static Ducted
Product Specifications

SYSTEM HIGH STATIC


INDOOR 42QSH090D8S 42QSH105D8S 42QSH125D8S-1 42QSH140D8S 42QSH170D8S
OUTDOOR 38QSH090D8S 38QSH105D8S 38QSH125D8S-1 38QSH140D8S 38QSH170D8S
Refrigerant type R32 R32 R32 R32 R32

Power supply (Volts-Phase-Hz) 220-240V /1/50Hz 220-240V /1/50Hz 220-240V /1/50Hz 220-240V /1/50Hz 220-240V /1/50Hz

Max input current A 21 21 31 30 31

Capacity - rated kW 8.60 10.05 12.40 13.60 16.20


Capacity - range (min
kW 2.40 ~ 11.70 2.40 ~ 11.70 3.2 ~ 17.95 4.08 ~ 16.43 3.52 ~ 20.80
~ max)
COOLING
Efficiency (rated) EER 3.37 3.14 3.38 3.14 3.29
Operating current
A 11.07 13.67 18.00 18.14 22.50
(rated)
Capacity - rated kW 9.14 10.40 12.80 14.00 17.00
Capacity - range (min
kW 2.09 ~ 12.49 2.09 ~ 12.49 2.73 ~ 18.45 3.33 ~ 18.42 2.93 ~ 21.10
~ max)
HEATING
Efficiency (rated) COP 3.94 3.66 3.94 3.74 3.91
Operating current
A 10.10 12.24 14.60 15.62 19.50
(rated)
Dimension (WxDxH) mm 1200x625x380 1200x625x380 1200x625x380 1200x625x380 1400x858x440

Net weight kg 54 54 53.3 54.3 81.1


Airflow volume
l/s 655/487/333 655/487/333 858/665/397 985/761/513 1056/833/635
INDOOR (H/M/L)
UNIT
ESP Rated / max Pa 37 / 200 37 / 200 50 / 200 50 / 200 50 / 200

Air inlet duct flange mm 1145 / 334 1145 / 334 1145 / 334 1145 / 334 1188 / 385

Air outlet duct flange mm 1000 / 253 1000 / 253 1000 / 253 1000 / 253 1188 / 385

Dimension (WxDxH) mm 946x410x810 946x410x810 952x415x1333 952x415x1333 952x415x1333

Net weight kg 70 70 97.7 97.7 97.7


dBA
OUTDOOR Operating noise
(@ 67 68 70 70 71
UNIT (sound power) (H)
swl)
Cooling usable
˚C 0~50 0~50 0~50 0~50 0~50
temperature range
Heating usable
˚C -20~24 -20~24 -20~24 -20~24 -20~24
temperature range
Liquid line Ø (mm) 9.52 9.52 9.52 9.52 9.52

Gas line Ø (mm) 15.9 15.9 15.9 15.9 19

Coupler style - flare flare flare flare flare


Drain (inside
PIPE SIZE mm 21 21 21 21 21
diameter) Ø
Maximum length m 75 75 75 75 75

Pre-charged length m 15 15 15 15 15
Maximum height
m 30 30 30 30 30
difference
Slim Ducted
Product Specifications

SYSTEM SLIM LINE DUCTED


INDOOR 42QSM053D8S 42QSM060D8S 42QSM070D8S 42QSM080D8S
OUTDOOR 38QSM053D8S 38QSM060D8S 38QSM070D8S 38QSM080D8S
Refrigerant type R32 R32 R32 R32

Power supply (Volts-Phase-Hz) 220-240V /1/50Hz 220-240V /1/50Hz 220-240V /1/50Hz 220-240V /1/50Hz

Max input current A 13.5 16 16 16

Capacity - rated kW 5.28 5.83 7.08 7.85


Capacity - range (min ~
kW 2.55 ~ 5.86 2.65 ~ 8.83 2.65 ~ 8.83 2.65 ~ 8.83
max)
COOLING
Efficiency (rated) EER 3.41 3.35 3.22 3.14
Operating current
A 7.1 7.27 9.16 10.44
(rated)
Capacity - rated kW 5.65 6.47 7.08 8.25
Capacity - range (min ~
kW 2.2 ~ 6.15 1.76 ~ 10.52 1.76 ~ 10.52 1.76 ~ 10.52
max)
HEATING
Efficiency (rated) COP 3.79 4.02 3.87 3.59
Operating current
A 6.8 6.57 7.44 9.32
(rated)
Dimension (WxDxH) mm 880x674x210 1100x774x249 1100x774x249 1100x774x249

Net weight kg 24.4 31.6 31.6 31.6

INDOOR Airflow volume (H/M/L) l/s 253/196/143 416/361/290 416/361/290 416/361/290


UNIT ESP Rated / max Pa 25 / 100 25 / 160 25 / 160 25 / 160

Air inlet duct flange mm 782 / 190 1001 / 228 1001 / 228 1001 / 228

Air outlet duct flange mm 706 / 136 926 / 175 926 / 175 926 / 175

Dimension (WxDxH) mm 805x330x554 890x342x673 890x342x673 890x342x673

Net weight kg 32.5 45 45 45


dBA
Operating noise (sound
OUTDOOR (@ 61 66 66.5 67
power) (H)
UNIT swl)
Cooling usable
˚C -10 ~ 46 0~50 0~50 0~50
temperature range
Heating usable
˚C -15~24 -20~24 -20~24 -20~24
temperature range
Liquid line Ø (mm) 6.35 9.52 9.52 9.52

Gas line Ø (mm) 12.7 15.9 15.9 15.9

Coupler style - flare flare flare flare

PIPE SIZE Drain (inside diameter) Ø mm 20 21 21 21

Maximum length m 30 50 50 50

Pre-charged length m 15 15 15 15
Maximum height
m 20 25 25 25
difference
Slim Ducted
Product Specifications

SYSTEM SLIM LINE DUCTED


INDOOR 42QSM090D8S 42QSM105D8S 42QSM125D8S 42QSM140D8S
OUTDOOR 38QSM090D8S 38QSM105D8S 38QSM125D8S 38QSM140D8S
Refrigerant type R32 R32 R32 R32

Power supply (Volts-Phase-Hz) 220-240V /1/50Hz 220-240V /1/50Hz 220-240V /1/50Hz 220-240V /1/50Hz

Max input current A 21 21 31 31

Capacity - rated kW 8.70 10.15 12.30 13.60


Capacity - range (min ~
kW 2.95 ~ 12.05 2.95 ~ 12.05 3.75 ~ 15.24 3.75 ~ 15.24
max)
COOLING
Efficiency (rated) EER 3.28 3.14 3.45 3.29
Operating current
A 11.29 13.79 16.30 18.00
(rated)
Capacity - rated kW 9.28 10.87 13.00 14.50
Capacity - range (min ~
kW 2.43 ~12.82 2.43 ~12.82 3.08 ~ 18.46 3.08 ~ 18.46
max)
HEATING
Efficiency (rated) COP 4.00 3.79 4.04 3.81
Operating current
A 10.14 12.40 14.40 17.00
(rated)
Dimension (WxDxH) mm 1360x774x249 1360x774x249 1200x874x300 1200x874x300

Net weight kg 39.9 39.9 47 47

INDOOR Airflow volume (H/M/L) l/s 615/489/326 615/489/326 525/428/258 525/428/258


UNIT ESP Rated / max Pa 37 / 160 37 / 160 50 / 160 50 / 160

Air inlet duct flange mm 1261 / 228 1261 / 228 1101 / 280 1101 / 280

Air outlet duct flange mm 1186 / 175 1186 / 175 1044 / 227 1044 / 227

Dimension (WxDxH) mm 946x410x810 946x410x810 952x415x1333 952x415x1333

Net weight kg 70 70 95.1 95.1


dBA
Operating noise (sound
OUTDOOR (@ 67 67 70 70
power) (H)
UNIT swl)
Cooling usable
˚C 0~50 0~50 0~50 0~50
temperature range
Heating usable
˚C -20~24 -20~24 -20~24 -20~24
temperature range
Liquid line Ø (mm) 9.52 9.52 9.52 9.52

Gas line Ø (mm) 15.9 15.9 19 19

Coupler style - flare flare flare flare

PIPE SIZE Drain (inside diameter) Ø mm 21 21 21 21

Maximum length m 75 75 75 75

Pre-charged length m 15 15 15 15
Maximum height
m 30 30 30 30
difference
Carrier Inverter Ducted Air Conditioners

AHIC is committed to continuously


improving its product to ensure
the highest quality and reliability
standards, and to meet local
regulations and market requirements.

Product specifications in this brochure


are only indicative and are subject to
change. These are not intended to be
used in place of the engineering or
installation book.

All features and specifications are


subject to change without prior
notice.

All images provided in this catalogue


are used for illustration purposes only.

Cooling and heating capacities


mentioned for the products are
nominal capacities
at standard operation conditions.

Equipment rates in accordance with INCLUDES


MEPS 3823.2-2011 E&OE PARTS & LABOUR
Part number: 1030-092022
Date: Sep 2023

MEPS MINIMUM
ENERGY
PERFORMANCE
COMPLIANT STANDARDS

MEPS SALES AND SERVICE: 13 COOL (13 2665)


COMPLIANT
AHIC (Australia) Pty Ltd- Level 1, 152 Wellington Road, Clayton, VIC 3168
ABN 37 606 792 456 AU 22499

carrierair.com.au