0% found this document useful (0 votes)
36 views1 page

Uls Fos Wallap

Table 8 summarizes design information from ultimate limit state (ULS) and serviceability limit state (SLS) analyses. The ULS analysis provides factors of safety (FoS) greater than 1 for stability and bending moments, while the SLS analysis provides FoS greater than 1.25 (drained) or 1.4 (undrained) as a partial indication of stability as well as bending moments and displacements. Design values for bending moments and prop forces are taken as the greater of values from ULS analysis or 1.35 times values from SLS analysis.

Uploaded by

BinSayeed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
36 views1 page

Uls Fos Wallap

Table 8 summarizes design information from ultimate limit state (ULS) and serviceability limit state (SLS) analyses. The ULS analysis provides factors of safety (FoS) greater than 1 for stability and bending moments, while the SLS analysis provides FoS greater than 1.25 (drained) or 1.4 (undrained) as a partial indication of stability as well as bending moments and displacements. Design values for bending moments and prop forces are taken as the greater of values from ULS analysis or 1.35 times values from SLS analysis.

Uploaded by

BinSayeed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Table 8 summarises the design information obtained form the ULS and SLS analyses.

A detailed
discussion is given in Sections 7.1 and 7.2.

Type of analysis

Limit Equilibrium Soil-Structure Interaction

Equilibrium BM solution
FoS > 1
Design information indicates stability.
indicates stability
obtained with
(for cantilever and
ULS parameters ULS bending moments.
single prop cases)
ULS strut forces.

FoS > 1.25 (drained)


or SLS bending moments
Design information
FoS > 1.4 (undrained) and displacements.
obtained with
SLS strut forces.
SLS parameters
is a partial indication of
stability

Table 8
7.1 Verification of Ultimate Limit State
7.1.1 Bending moment
C580 (§ 6.6.2) states the ULS verification procedure as follows:
The ULS wall bending moments (MWd) and shear forces for use in the structural
design of the wall should be obtained as the greater of:
• the maximum bending moment from the ULS analyses (MULS)
• 1.35 times the maximum bending moment from the SLS analyses (MSLS)
What is being said here is that we have two versions of the design bending moment (MWd). One is derived
directly from the ULS analysis. The other is derived by considering the bending moment from the SLS
analysis to be the characteristic value of a permanent action (the bending moment) which is multiplied by
1.35 (Table 4, Column A1) to obtain the design bending moment. To summarise:
MWd is the greater of MULS or 1.35MSLS
The ultimate bending resistance of the wall, MWult, is related to the design bending moment, MWd, by:
MWd ≤ MWult / γMw.
For steel walls γMw = 1.0 i.e. subject to the provisos below you can use the Ultimate Moment Capacities
straight out of the "Table of steel pile moment capacities" in the WALLAP help system. There is no
distinction between moment capacities for temporary and permanent situations.
For reinforced concrete walls a proper design must be carried out for the concrete and steel section.
Eurocode 2 specifies
γM = γc = 1.5 for concrete
γM = γs = 1.15 for reinforcing bars
Bear in mind that:
• Bending and shear resistance are influenced by vertical loads in the wall.
• the characteristic bending strength of the wall may reduce with time e.g.
due to corrosion.

7.1.2 Prop forces (struts and anchors)


C580 (§7.4) states the ULS verification procedure as follows:
The ULS prop load (PPd) for use in the design of the struts/anchors should be
determined as the greater of:
• the prop force from the ULS analyses (PULS)
• 1.35 times the maximum prop force from the SLS analyses (PSLS)
The logic concerning the alternative forces is the same as for the bending moments (Section 7.1.1). To
summarise:
PPd is the greater of PULS or 1.35PSLS

WALLAP and Eurocode 7 p.19