Post Tension
Post Tension
No. of Tendons = 1
Dia of Duct = 90 mm
Height of Girder = 1300 mm
Anchorage Mid
tendon offset from girder soffit (mm) 400 100
c/c distance b/w tendons (mm) 0 0
Prestress Characteristics
Strand Type 15.4 mm dia seven-wire super stabilised low-relaxation strands
Ultimate Tensile Strength 1860 Mpa
modulus of elasticity 197 GPa
cross section area per strand 140 mm² 0 5 10
1400
Minimum breaking load 260.4 kN per strand
jacking (percentage of breaking load) 75%
1200
No. of strands per tendon 13
jacking force per tendon 2538.9
total no. of Tendons in girder 1 1000
Span L 25 (m)
Pjack 2538.9 (kN)
yb nc 0.395732 (m)
C1 6211.79 rad
EI 551.8611 (MNm²)
GRAPH POINTS
Girder
x 0 25 25 0 0
y 0 0 1300 1300 0
Girder CG
x 0 25
y 395.732 395.732
Tendons
x 0 2.5 5 7.5 10 12.5 15 17.5
ow-relaxation strands
100
80
60
40
20
0
0.35L 0.40L 0.45L 0.50L 0.55L 0.60L 0.65L 0.70L 0.75L
8.75 10 11.25 12.5 13.75 15 16.25 17.5 18.75
0.127 0.112 0.103 0.1 0.103 0.112 0.127 0.148 0.175
-0.0144 -0.0096 -0.0048 0 0.0048 0.0096 0.0144 0.0192 0.024
260.5 260.5 260.4 260.4 260.4 260.5 260.5 260.6 260.6
20 22.5 25 0
0
0.80L 0.85L 0.90L 0.95L 1.00L
20 21.25 22.5 23.75 25
0.208 0.247 0.292 0.343 0.4
0.0288 0.0336 0.0384 0.0432 0.048
260.7 260.9 261.0 261.1 261.3
0 0 0 0 0
67.18542337 71.27541928 75.35281699 79.41765531 83.46997293