0% found this document useful (0 votes)
4K views1 page

How To Check Error Code 01

Error code 01 indicates a fan problem where the fan is locked when the inverter is turned off. To troubleshoot, disconnect all power sources except the battery and turn on the inverter to check if the problem persists. If so, check if the fan is running or blocked, and clear any obstructions. Also check that the fan wiring is securely connected. If the fan still does not run after ensuring proper wiring and clearing obstructions, replace the fan with the same model.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
4K views1 page

How To Check Error Code 01

Error code 01 indicates a fan problem where the fan is locked when the inverter is turned off. To troubleshoot, disconnect all power sources except the battery and turn on the inverter to check if the problem persists. If so, check if the fan is running or blocked, and clear any obstructions. Also check that the fan wiring is securely connected. If the fan still does not run after ensuring proper wiring and clearing obstructions, replace the fan with the same model.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Trouble shooting for error 01

Suitable for SAKO inverter: SUNSEE/SUNON/SUNON PLUS/SUNPOLO


Error code 01: Fan problem (Fan is locked when inverter is turned off)
Trouble shooting:
Step 1. Disconnect the load, grid input and solar input,just connect with battery and turn on the inverter. If
still problem, go to step 2
Step 2. Check if the fan works or not. If fans doesn’t run, check if anything block the fan. If the fan is blocked
and doesn’t run, go to step 3
Step 3. Disconnect the input power source, open the cover, and check if the fan wire is well connected or get
loosed. If get loosed, make the well connected. If there is nothing block the fan and wires are well connected,
fan stil not run, go to step 4

Step 4. If step 1-3 have been well checked and the fan still not work, replace the fan (need same model)