Timoteo Residence - Structural02

This document provides general notes for a two storey residence project including design references, loading criteria, and a site plan layout. The design references include various concrete and steel standards. Loading criteria specifies dead loads for reinforced concrete and structural steel, as well as wind loads calculated based on national structural codes. A site plan shows the layout of the building.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
28 views1 page

Timoteo Residence - Structural02

This document provides general notes for a two storey residence project including design references, loading criteria, and a site plan layout. The design references include various concrete and steel standards. Loading criteria specifies dead loads for reinforced concrete and structural steel, as well as wind loads calculated based on national structural codes. A site plan shows the layout of the building.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Project:

1 2 3 4 1 2 3 4
GENERAL NOTES TWO STOREY RESIDENCE
A. DESIGN REFENRENCES
5925 5925
A. AMERICAN CONCRETE INSTITUTE ( ACI PUBLICATIONS ) E. AMERICAN WELDING SOCIETY (AWS) PUBLICATION D.1.1-2000
B. ACI 318-2005 BUILDING CODE REQUIREMENTS FOR F. AMERICAN SOCIETY FOR TESTING MATERIALS (ASTM)
STRUCTURAL CONCRETE G. NATIONAL STRUCTURAL CODE OF THE PHILIPPINES (NSCP), 6TH 2413 1400 2113 2413 1400 2113
C. ACI 315-80 MANUAL OF STANDARD PRACTICE FOR DETAILS EDITION
AND DETAILING OF CONCRETE REINFORCEMENT Location:
H. ASSOCIATION OF STRUCTURAL ENGINEERS OF THE PHILIPPINES
D. AMERICAN INSTITUTE OF STEEL CONSTRUCTION (ASEP) HANDBOOK OF STRUCTURAL STEEL SHAPES AND
PUBLICATION:MANUAL OF STEEL CONSTRUCTION, NINTH SECTIONS, 1987 C1F1 Enter address here
C1F1
EDITION "ALLOWABLE STRESS DESIGN" I. UNIFORM BUILDING CODE (UBC), VOL 2 1997 EDITION B-1 B-1 B-1
B. LOADING CRITERIA A A
Owner:
A. DEAD LOADS C. WIND LOAD (WL) C1F1 C1F1
100MM SLAB ON FILL

B-1
2213

2213
A.1. REINFORCED CONCRETE 150 pcf 24 KN/m3

B-1
ALL LOADINGS APPLICABLE TO THE STRUCTURE AND BUILDING WITH 10MM DIA @ 300MM E.W. S-1

B-1
77 KN/m3

3213

3213
A.2. STRUCTURAL STEEL 490 pcf SHALL BE COMPUTED BASED ON THE NATIONAL STRUCTURAL S-1
ON A WELL COMPACTED GRAVEL

B-1
A.3. SUPERIMPOSED DEAD LOADS: CODE OF THE PHILIPPINES 6TH EDITION (2010) IN
BED 50MM THK B-1
A.3.1. CEILING & CEILING SUSPENSION SYSTEM 5 psf 0.24 KPa
CONSIDERATION OF THE FOLLOWING:
B B Owner
A.3.2. 150mm THK. CHB WALL (VERTICAL AREA) 57 psf 2.73 KPa WIND VELOCITY, V 200 kph
2.11 KPa C1F1 C1F1 B-1
A,3.3. 100mm THK. CHB WALL (VERTICAL AREA) 44 psf OCCUPANCY CATEGORY III
-

B-1
A.3.4. FLOOR FINISH 25 psf 1.20 KPa IMPORTANCE FACTOR, Iw 1.15

2300

2300
S-1
A.3.5. INTERIOR PARTITION (HOR. AREA) 20 psf 0.96 KPa EXPOSURE TYPE C

7425

7425
A.3.6. WATER FROOFING 5 psf 0.24 KPa VELOCITY PRESSURE 47.3E-6.Kz.Kzt.V².Iw C1F1

A.3.7. MEPF UTILITIES 10 psf 0.48 KPa


C C2F2
C STAIRWELL

B-1
B. LIVE LOADS D. SEISMIC LOAD (EQ)

3213

3213
B-1 S-1
B.1. LIGHT ROOF LIVE LOADS
ALL LOADINGS APPLICABLE TO THE STRUCTURE AND BUILDING
C1F1
Engineering Consultant:

1713

1713

B-1
TRIBUTARY AREA 20 m² 20 psf 0.96 KN/m² SHALL BE COMPUTED BASED ON THE NATIONAL STRUCTURAL
20 < A <60 m² 16 psf 0.77 KN/m² CODE OF THE PHILIPPINES 6TH EDITION (2010) IN
CONSIDERATION OF THE FOLLOWING: C1F1

B-1
S-1
D D
60 < m² 12 psf 0.56 KN/m²
B.2. TYPICAL OFFICE FLOOR 50 psf 2.40 KN/m² SEISMIC ZONE FACTOR, Z 0.40 (ZONE 4)

1200

1200

B-1

B-1
B.3. LIGHT STORAGE 125 psf 6.00 KN/m² IMPORTANCE FACTOR, I 1.0

1200

1200
C1F1
12.00 KN/m² S-1
B.4. POWER CENTER 250 psf SOIL PROFILE TYPE SD
B.5. ROOF DECK 100 psf 4.80 KN/m² SEISMIC SOURCE TYPE A E E B-1 B-1
RHAF ANTHONY D. BARRANTES
B.6. LOBBIES, PARKING, HALLWAYS, STAIRS 100 psf 4.80 KN/m² NEAR SOURCE FACTOR, Na 1.0
C1F1 C1F1
B.7. BLOWER ROOM/ELECTRICAL ROOM/MACHINE ROOM 150 psf 7.20 KN/m² NEAR SOURCE FACTOR, Nv 1.0 ENGINEER
B.8. TANKS/PUMP ROOM 100 psf 4.80 KN/m² GLOBAL DUCTILITY CAPACITY, R 8.5
B.9. VAULT ROOM/RAMPS/DRIVERWAYS 100 psf 4.80 KN/m² DISTANCE TO SOURCE 38 kM 3813 2113
REG. NO.:0161015 PTR. NO.: 0166910
C. GENERAL
DATE: 05/28/2018 PLACE: NAVOTAS CITY
1. CONSTRUCTION NOTES AND TYPICAL DETAILS APPLY TO ALL DRAWINGS UNLESS OTHERWISE SHOWN OR NOTED. MODIFY TYPICAL
DETAILS AS DIRECTED TO MEET SPECIAL CONDITIONS. FOUNDATION PLAN SECOND FLOOR FRAMING PLAN
2. SHOP DRAWINGS WITH ERECTION AND PLACING DIAGRAMS OF ALL STRUCTURAL STEEL, MISCELLANEOUS IRON, PRE-CAST CONCRETE
ETC. SHALL BE SUBMITTED FOR ENGINEER'S APPROVAL BEFORE FABRICATION.
3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE ALL WORK IS TO BEGIN, CHECK WITH MECHANICAL AND ELECTRICAL
1 1 : 100
2 1 : 100
CONTRACTORS FOR CONDUITS, PIPE SLEEVES, ETC. TO BE EMBEDDED IN CONCRETE. RA 9266, Article IV section 33
Drawings and documents duly signed, stamped or sealed,as
4. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADEQUATE SHORINGS AND BRACINGS OF THE STRUCTURE FOR ALL instruments of Service, are the intellectual Property and
LOADS THAT MAYBE IMPOSED DURING CONSTRUCTION. Documents of the Architect,wether the object for which they are
made is executed or not, it shall be unlawful for any person to
LENGTH
D. CONCRETE & REINFORCEMENT 200 200 L/4 3-16mm∅ TOP L/4
duplicate or to make copies of said Documents for use in the
repetition of and for other projects or buildings, wether executed
partly or whole, without the written consent of the Architect or
1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM WITH THE LATEST BULDING CODE OF AMERICAN CONCRETE INSTITUTE (ACI-318). L/5 2-16mm∅
BARS L/5
Author of the said Documents.
2. ALL CONCRETE SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH AT THE END OF TWENTY EIGHT (28) DAYS WITH CORRESPONDING MID-BARS
All measurements are to be verified on site by the Contractor.
MAXIMUM SIZE AGGREGATE AND SLUMPS AS FOLLOWS : All discrepancies are to be immediately reported to the Architect
and Project Managers.

300

300
Contractors are to prepare and submit Shop Drawings to the
28-DAY 3-16mm∅ BOTTOM Architect prior to commencement of works.
STRUCTURALCOMPRESSIVE MAX. SLUMP @ @
LOCATION BARS
ELEMENTS STRENGTH MPa (psi) mm (in)
SUPPORT MIDSPAN 10mm∅ TIES SPACED 7 @
FOUNDATION PILECAP 41.4 (6000) 100 (4") 100mm 5@150mm, REST @
FOUNDATION TO 3RD LVL SLABS, BEAMS, COLUMNS 41.4 (6000) 100 (4") 200mm OC
3RD LVL TO UTILITY DECK LVL SLABS, BEAMS, COLUMNS 34.5 (5000) 100 (4") FOR RB Sheet Contents:
STP/CISTERN/FUEL TANK SLABS, BEAMS, RCWALL 41.4 (6000) 100 (4")

LENGTH
3. ALL REINFORCING BARS SHALL CONFORM TO ASTM A615 GRADE 60 FOR DIA. 12 AND LARGER BARS AND GRADE 40 FOR DIA. 10 200 200 L/4 2-16mm∅ TOP L/4
AND SMALLER BARS. L/5 2-16mm∅
BARS L/5
4. IN GENERAL, THE LATEST EDITION OF ACI-315, MANUAL OF STANDARD PRACTICE DETAILING REINFORCED CONCRETE STRUCTURES MID-BARS
SHALL BE ADHERED TO, UNLESS OTHERWISE SHOWN OR NOTED.
5. MAINTAIN MINIMUM CONCRETE COVER FOR REINFORCING STEEL AS FOLLOWS:

400

400
SUSPENDED SLABS 3/4 IN. ( 19 MM. )
2-16mm∅ BOTTOM
SLAB ON GRADE 1 1/2 IN. ( 38 MM. ) @ @ BARS
WALLS ABOVE GRADE 1 IN. ( 25 MM. ) SUPPORT MIDSPAN 10mm∅ TIES SPACED 7 @
BEAM STIRRUPS AND COLUMN 1 1/2 IN. ( 38 MM. )
100mm 5@150mm, REST @ FOUNDATION PLAN, SECOND FLOOR
WHERE CONCRETE TIES
IS EXPOSED TO EARTH 2 IN. ( 50 MM. 200mm OC FRAMING PLAN, ROOF FRAMING
BUT POURED AGAINST FORMS ) PLAN, COLUMN & WALL FOOTING
WHERE CONCRETE IS DEPOSITED DIRECTLY AGAINST EARTH 3 IN. ( 75 MM.
DETAILS & BEAM DETAILS
) FOR B-1

RC BEAM DETAILS
6. SPLICES SHALL BE SECURELY WIRED TOGETHER AND SHALL LAP OR EXTEND IN ACCORDANCE WITH TABLE 1 (TABLE OF LAP SPLICE
AND ANCHORAGE LENGTH) UNLESS OTHERWISE SHOWN ON DRAWINGS, SPLICES SHALL BE STAGGERED WHENEVER POSSIBLE.
7. ALL ANCHOR BOLTS, DOWELS, AND OTHER INSERTS, SHALL BE PROPERLY POSITIONED AND SECURED IN PLACE PRIOR TO PLACING
OF CONCRETE.
8. CONTRACTOR SHALL NOTE AND PROVIDE ALL MISCELLANEOUS CURBS, SILLS, STOOLS, EQUIPMENTS, AND MECHANICAL BASES THAT 1 : 100
ARE REQUIRED BY THE ARCHITECTURAL, ELECTRICAL, AND MECHANICAL DRAWINGS.
9. ALL CONCRETE SHALL BE KEPT MOIST FOR A MINIMUM OF SEVEN (7) CONSECUTIVE DAYS IMMEDIATELY AFTER POURING \BY THE
USE OF WET BURLAP, FOG SPRAYING, CURING COMPOUNDS OR OTHER APPROVED METHODS.
10. STRIPPING OF FORMS AND SHORES: 2-12mm Ø, 6-16 mm Ø RSB 4-16Ø mm RSB 5" THK CHB WALL WITH 10 mm dia.
VERTICAL BARS W/ VERTICAL BARS W/ VERT. BARS AT 0.80 AND HOR. BARS AT
FOUNDATION 24 HRS.
10mmØ TIES 10mmØ TIES EVERY 3 LAYERS OF CHB
SUSPENDED SLAB EXCEPT WHEN ADDITIONAL LOADS ARE IMPOSED 8 DAYS
WALLS 18 HRS. SP.@ 7-0.10, SP.@ 7-0.10,
BEAMS 14 DAYS 5-0.15, 0.20 REST 5-0.15, 0.20 REST

E. CONCRETE NOTES
N G L N G L NGL Drawn By: Author Date:
Checked By: - Designed By: -
ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE MINIMUM REQUIREMENTS OF THE NATIONAL STRUCTURAL CODE OF THE PHILIPPINES
(NSCP) 2010 OR THE AMERICAN CONCRETE INSTITUTE BUILDING CODE FOR REINFORCED CONCRETE ACI 318-EXCEPT AS MODIFIED HEREIN. Date Description By:
1. CONSTRUCTION OR COLD JOINTS SHALL BE LOCATED WITHIN THE MIDDLE THIRD OF SPANS OF SLABS, BEAMS, AND GIRDERS. FOR
CASE UNAVOIDABLE, PROPOSED LOCATION MUST BE APPROVED FIRST BY THE STRUCTURAL ENGINEER. Schematic Des.
2. PIPES OR DUCTS EXCEEDING ONE THIRD THE SLAB OR WALL THICKNESS SHALL NOT BE PLACED IN STRUCTURAL CONCRETE UNLESS 1.50 1.50
Design Dev't.
SPECIFICALLY DETAILED.
For HLURB
3. REINFORCING BARS, ANCHOR BOLTS, AND OTHER INSERTS SHALL BE SECURED IN PLACE BEFORE POURING CONCRETE. BAR
PLACEMENT AND SUPPORTS SHALL BE IN ACCORDANCE WITH THE RECOMMENDED ACI PRACTICE. 3-10 mm dia. CONT. DEF 0.60m
For Bldg. Permit
4. ALL INSERTS, ANCHOR BOLTS, ETC. TO BE EMBEDDED IN THE CONCRETE SHALL BE HOT DIP GALVANIZED UNLESS NOTED OTHERWISE. BARS WITH 10 mm dia.
5. IN GENERAL, THE LATEST EDITION OF THE MANUAL OF STANDARD PRACTICE FOR DETAILING CONCRETE STRUCTURES, ACI 315, SHALL Contract Doc.
BE ADHERED TO, UNLESS SHOWN OTHERWISE. TIES AT 0.30 M. O. C. For Bidding
6. USE OF ADMIXTURES IS PERMITTED TO PRODUCE PROPER SLUMP AND WORKABILITY BUT SUBJECT TO THE ENGINEER'S APPROVAL. 0.30 0.30 0.30m
ADDITION OF WATER TO CONCRETE AT JOB SITE IS NOT ALLOWED. For Construction
7. PREPARE AND SUBMIT CONCRETE MIX DESIGN INCLUDING AGGREGATES GRADATION, WATER AND CEMENT CONTENTS, AND CYLINDER
STRENGTH TEST RESULT FOR REVIEW.
F. CAMBER REQUIREMENTS SECTION 12mmØ RSB SECTION 12mmØ RSB 0.40m Rev. Date
Constn. Bulletin
Description By:
[email protected] BOTHWAYS [email protected] BOTHWAYS
1. UNLESS OTHERWISE NOTED ON THE PLANS OR SPECIFICATIONS CAMBER ALL RC BEAMS AT LEAST 10mm. FOR EVERY 4000mm. OF
CLEAR SPAN EXCEPT CANTILEVERS WHICH SHALL BE 50mm. FOR EVERY 3000mm. OF CLEAR SPAN.
2. UNLESS OTHERWISE NOTED IN PLANS OR SPECIFICATIONS, CAMBER ALL SLABS 8mm PER 3000mm. OF SHORTER SPAN AND 14mm.
FOR EVERY 2000mm. OF SLABS CANTILEVER SPAN
2-12mm Ø, 6-16 mm Ø RSB
VERTICAL BARS W/
4-16 mm Ø RSB
VERTICAL BARS W/ WF-1
G. FOUNDATION 10mmØ TIES 10mmØ TIES
0.40 SP.@ 7-0.10,
1. FOUNDATION IS DESIGNED BASED ON BORED PILE CAPACITY PROVIDEDMIGUEL
BY DIMADURA, M. CivEng
1.20 SP.@ 7-0.10, 1.0
2. FOUNDATION SHALL REST ON NATURAL SOIL. UNLESS OTHERWISE NOTED BY THE ENGINEER, NO PART OF THE FOUNDATION SHALL REST 5-0.15, 0.20 REST 0.20 5-0.15, 0.20 REST Cad File Ref.:
ON FILL.
3. THE CONTRACTOR SHALL NOTIFY THE ENGINEER AFTER FOOTING EXCAVATION HAVE BEEN COMPLETED AND PRIOR TO CONCRETING TO
CONFIRM THE DESIGN SOIL BEARING CAPACITY.
Last Modified:

0.30 Sheet No.:


0.20

1.0

S-01
1.20

PLAN (C1F1) PLAN (C2F2)

You might also like