04-D2C&D2H - Using Display and Keyboard
04-D2C&D2H - Using Display and Keyboard
DYNAC VECTOR II
Using display and keyboard.
Password levels
2
©2015 Konecranes Plc. All right reserved 2
Display
3
©2015 Konecranes Plc. All right reserved 3
Display
Text lines:
Status LEDs :
ready green Illuminates the AC-supply is on
run green Illuminates during run
fault red Illuminates due to fault trip
4
©2015 Konecranes Plc. All right reserved 4
Control keypad operation
Button descriptions :
5
©2015 Konecranes Plc. All right reserved 5
Control keypad operation
Clear
6
©2015 Konecranes Plc. All right reserved 6
Using keyboard
M8.
STOP READY
I/O term
H8.1.
STOP READY
I/O term
T8.1.1.
STOP READY
I/O term • Intuitive keyboard for changing and
Fault History 57 Thermistor Operation days
H1→Hxx → F T1→T13 → 0 monitoring of the parameters;
STOP READY
Active Faults
F0
• Better to try using keyboard than to hear
STOP READY STOP READY STOP READY
how to use it.
M6. I/O term
S6.7. I/O term
I 6.7.2. I/O term
7
©2015 Konecranes Plc. All right reserved 7
Using keyboard
8
©2015 Konecranes Plc. All right reserved 8
Parameter backup in control unit
• Group 4.1
• Three parameter groups:
– Active parameters
– User parameters
– Default parameters
• Loading/Saving
• Default parameter saving is for factory
Active
Parameters use only
User parameters
B4.1.3 Load ( Set 2 ) B4.1.2 Save
User Par User Par
Default parameters
( Set 1 )
B4.1.1 Load B4.1.4.1 Save
Default Par Default Par
(for factory
Factory Settings use only)
(Software Defaults)
NOTE! Not in
commercial use.
9
©2015 Konecranes Plc. All right reserved 9
Parameters saving on a display
reset
S TO P
select enter
10
©2015 Konecranes Plc. All right reserved 10
Monitoring
10.0 A 400.0 V
50.00 Hz
ready run fault
START
reset
STOP
select enter
11
©2015 Konecranes Plc. All right reserved 11
Monitoring
12
©2015 Konecranes Plc. All right reserved 12
Parameters groups
+ sign in the front of the Group code means that group is visible in panel, when group function is selected. – According to the password access
G3 Parameters
G3.1 Basic Parameter
different parameters groups can be
G3.2 I/O Parameters changed ;
G3.2.1 Digital Inputs
G3.2.2 Analog Input 1
G3.2.3 Analog Input 2
+ G3.2.3.7 AU-Speed Ref – You can view only the groups that are
+ G3.2.3.8 Torque Reference
+ G3.2.3.9 Speed Correction allowed by your password access;
+ G3.2.3.10 Torque Limit
+ G3.2.3.11 Load Feedback
G3.2.4 Analog Output
G3.2.4.1 Aout1 Function – List of all parameters can be found in
G3.2.4.2 Aout2 Function
G3.2.5 Relay Outputs parameter manual.
G3.3 Drive Control
G3.3.6 Limit Functions
+ G3.3.7 Ramp2
G3.3.8 Advanced Ramps
+ G3.3.9 Multistep
+ G3.3.10 SSU
G3.3.11 Prohib Freq
+ G3.3.12 Multicare
G3.3.12.1 Multicare 1
G3.3.12.2 Multicare 2
G3.3.13 Torque Control
G3.3.14 Load Control
13
©2015 Konecranes Plc. All right reserved 13
Access levels and passwords
• Full list of the parameters and required access level can be found in
a Drive Parameters Manual.
• Level 1 – Access denied- password 0
• Level 2 – Start-up - password 26
• Level 3 – Engineering- password 768
– password 2419
14
©2015 Konecranes Plc. All right reserved 14
Access level for start-up
15
©2015 Konecranes Plc. All right reserved 15
Engineering access level
«+» before the group means that the group will be shown, when its’ function is activated
G3 Parameters
G3.1 Basic Parameter
G3.2 I/O Parameters
G3.2.1 Digital Inputs
G3.2.2 Analog Input 1
G3.2.3 Analog Input 2
+ G3.2.3.7 AU-Speed Ref Example of
G3.2.4 Analog Output
G3.2.4.1 Aout1 Function
displaying of
G3.2.4.2 Aout2 Function parameters groups
G3.2.5 Relay Outputs
G3.3 Drive Control for closed loop
G3.3.6 Limit Functions system
G3.3.8 Advanced Ramps
+ G3.3.10 SSU
G3.3.11 Prohib Freq
G3.3.13 Torque Control
G3.3.14 Load Control
G3.4 Motor Parameter
G3.4.1 Motorset 1
G3.4.1.20 Additional
G3.4.1.21 ESR
+ G3.4.3 Closed Loop 1
G3.4.6.5 Brake Control
G3.6 Protection
16
©2015 Konecranes Plc. All right reserved 16
Menu Group 3 Parameters
• Password setting
• Includes basic parameters for adjusting motor,
• Digital and analog input and output;
• Selection and adjustment of the motor in an open loop or closed loop
system.
• Address setting and setup parameters of the profibas system
17
©2015 Konecranes Plc. All right reserved 17
Menu Group 4 Monitoring
18
©2015 Konecranes Plc. All right reserved 18
Menu Group 6 System Menu
• Includes drive system information. Also shows menus that are not
supported by crane software.
• Copy Parameters: Up to Keypad, Down from Keypad;
• Parameters Comparison;
• Keypad settings;
• System Info;
• Fan control.
19
©2015 Konecranes Plc. All right reserved 19
Menu Group 7 & 8
Active Faults and Fault History
20
©2015 Konecranes Plc. All right reserved 20
NOT JUST LIFTING
THINGS, BUT ENTIRE
BUSINESSES
21
©2015 Konecranes Plc. All right reserved 21