Toaz - Info Asme Sec Ix Wps Welding Variables and Data Smaw Saw Gtaw PR
Toaz - Info Asme Sec Ix Wps Welding Variables and Data Smaw Saw Gtaw PR
Toaz - Info Asme Sec Ix Wps Welding Variables and Data Smaw Saw Gtaw PR
Legend:
+ Addition, > Increase/greater than, ↑ Uphill, ← Forehand, ɸ Change
− Deletion, < Decrease/less than, ↓ Downhill, → Backhand
QW-254
WELDING VARIABLES, PROCEDURE SPECIFICATIONS (WPS)
Submerged-Arc Welding (SAW)
(ASME Sec IX, 2010)
Paragraph Brief of Variables Essential Supple Non
mentary essential
Essential
QW-402 Joints 0.1 ɸ Groove design X
0.4 - Backing X
0.10 ɸ Root spacing X
0.11 ± Retainers X
QW-403 Base 0.5 ɸ Group Number X
Metals 0.6 T Limits X
0.8 ɸ T Qualified X
0.9 t Pass > 1⁄2 in. (13 mm) X
0.11 ɸ P-No. qualified X
QW-404 Filler 0.4 ɸ F-Number X
Metals 0.5 ɸ A-Number X
0.6 ɸ Diameter X
0.9 ɸ Flux/wire class. X
0.10 ɸ Alloy flux X
0.24 ±,ɸ Supplemental X
0.27 ɸ Alloy elements X
0.29 ɸ Flux designation X
0.30 ɸ t X
0.33 ɸ Classification X
0.34 ɸ Flux type X
0.35 ɸ Flux/wire class. X X
0.36 Recrushed slag X
QW-405, Position 0.1 + Position X
Legend:
+ Addition, > Increase/greater than, ↑ Uphill, ← Forehand, ɸ Change
− Deletion, < Decrease/less than, ↓ Downhill, → Backhand
QW-256
WELDING VARIABLES, PROCEDURE SPECIFICATIONS (WPS)
Gas Tungsten-Arc Welding (GTAW)
(ASME Sec IX, 2010)
Paragraph Brief of Variables Essential Supple Non
mentary essential
Essential
QW-402 Joints 0.1 ɸ Groove design X
0.5 + Backing X
0.10 ɸ Root spacing X
0.11 ± Retainers X
QW-403 Base 0.5 ɸ Group Number X
Metals 0.6 T Limits X
0.8 T Qualified X
0.11 ɸ P-No. qualified X
QW-404 Filler 0.3 ɸ Size X
Metals 0.4 ɸ F-Number X
0.5 ɸ A-Number X
0.12 ɸ Classification X
0.14 ± Filler X
0.22 ± Consumable.insert X
0.23 ɸ Filler metal product form X
0.30 ɸ t X
0.33 ɸ Classification X
0.50 ± Flux X
QW-405 Position 0.1 + Position X
0.2 ɸ Position X
0.3 ɸ ↑↓ Vertical welding X
QW-406 Preheat 0.1 Decrease > 100°F (55°C) X
0.3 Increase > 100°F (55°C) (IP) X
QW-407 PWHT 0.1 ɸ PWHT X
0.2 ɸ PWHT (T & T range) X
0.4 T Limits X
QW-408 Gas 0.1 ± Trail or . comp. X
0.2 ɸ Single, mixture, or % X
0.3 ɸ Flow rate X
0.5 ± or ɸ Backing flow X
0.9 - Backing or comp X
0.10 ɸ Shielding or trailing X
QW-409 Elec 0.1 > Heat input X
Characteristics 0.3 ± Pulsing I X
0.4 ɸ Current or polarity X X
0.8 ɸ I & E range X
0.12 ɸ Tungsten electrode X
QW-410 0.1 ɸ String/weave X
Technique 0.3 ɸ Orifice, cup, or nozzle size X
0.5 ɸ Method cleaning X
0.6 ɸ Method back gouge X
0.7 ɸ Oscillation X
Technique
Legend:
+ Addition, > Increase/greater than, ↑ Uphill, ← Forehand, ɸ Change
− Deletion, < Decrease/less than, ↓ Downhill, → Backhand
Legend:
+ Addition, > Increase/greater than, ↑ Uphill, ← Forehand, ΦC
− Deletion, < Decrease/less than, ↓ Downhill, → Backhand
Uphill, ← Forehand, Φ Change
Downhill, → Backhand