After installing ProVisionaire Edge, launch the settings program and select the network interfaces to be used. Only one IP address should be assigned per interface. ProVisionaire Edge can monitor devices on a single subnet using one PC, and disruptions may occur if using multiple PCs or with ProVisionaire Monitoring Service. Once the PC and devices are connected to the network with IP addresses set, ProVisionaire Edge will automatically detect and register compatible devices for monitoring.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
53 views2 pages

ProVisionaire Edge Setup Manual EN

After installing ProVisionaire Edge, launch the settings program and select the network interfaces to be used. Only one IP address should be assigned per interface. ProVisionaire Edge can monitor devices on a single subnet using one PC, and disruptions may occur if using multiple PCs or with ProVisionaire Monitoring Service. Once the PC and devices are connected to the network with IP addresses set, ProVisionaire Edge will automatically detect and register compatible devices for monitoring.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

ProVisionaire Edge Setup

Thank you for downloading ProVisionaire Edge. This document describes how to set up ProVisionaire Edge
after installation. For the latest information on system requirements and compatible devices, please visit the
download page.

Initial Configuration of ProVisionaire Edge

After installing ProVisionaire Edge, launch "ProVisionaire Edge Setting" from the Windows menu and select
the network interfaces to be used.

Note 1 - IP address allocation for network interfaces

Only one IP address should be assigned to each network interface on ProVisionaire Edge. If you want to assign
multiple IP addresses to monitor several subnets, you will need to add additional network interfaces on your PC:
one interface for each IP address.

Note 2 - Number of PCs running ProVisionaire Edge

ProVisionaire Edge can run on one PC within a single subnet. If ProVisionaire Edge is running on more than one
PC, communication between other ProVisionaire applications and devices may be disrupted. Also, it cannot be
used in conjunction with ProVisionaire Monitoring Service: use ProVisionaire Edge instead of ProVisionaire
Monitoring Service.
Connections and IP addresses of compatible devices

Once you have set the IP addresses of the PC and the devices to be monitored, connect them to the network(s) -
ProVisionaire Edge automatically detects the compatible devices and registers them for monitoring.
For the latest supported devices and supported firmware versions, see the download page.
As of September 2023
Device Connector IP Address IP Address Setting
NETWORK
DM7 series *1 Any SETUP -> NETWORK -> FOR MIXER CONTROL
connector

RIVAGE PM series NETWORK [PC] 192.168.53.xxx


Cannot be changed.
(console, DSP) *2 connector (fixed)

NETWORK
CL/QL series *3 Any SETUP -> NETWORK -> FOR MIXER CONTROL
connector

Dante Primary
Rio-D2 series Any SETUP -> IP ADDRESS
connector

NETWORK
DME7 *3 Any Settings -> IP Settings -> DME Control Port
connector

Dante Primary Set by UNIT ID and DIP switches to 192.168.0.xxx, or by MTX-MRX Editor to
MRX7-D, MTX5-D Any
connector any address.

NETWORK Set by UNIT ID and DIP switches to 192.168.0.xxx, or by MTX-MRX Editor to


MTX3 *3 Any
connector any address.

NETWORK
PC-D series Any NETWORK -> CONTROL
connector

NETWORK Set by UNIT ID and DIP switches to 192.168.0.xxx, or by Amp Editor to any
XMV series *3 Any
connector address.

Dante Primary Set by UNIT ID and DIP switches to 192.168.0.xxx, or by Amp Editor to any
XMV-D series Any
connector address.

Expansion slot
Nexo NXAMPmkII series*4 Any REMOTE CONTROL SETTINGS
connector

Dante Primary
DZR/DXS-D series Any UTILITY -> NETWORK
connector

*1 - DME7 Control is not automatically detected. Please specify it with Manual IP.
*2 - It is recommended to use a dedicated network interface connected to the Network [PC] terminal of RIVAGE PM series for the best system
performance. Other devices should be connected via different network interfaces.

*3 - In order to reduce communication load on device NETWORK control terminals, it is recommended that devices connected via NETWORK control
terminals use different network interfaces from the Dante network.
*4 - For monitoring Nexo NXAMPmkII series amplifiers, use the NXRM104 or NXAE104 cards only.