39 Cid 246

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

TH355B TH360B Telehandler SLE00001-UP (MACHINE) POWERED BY 3054E E...

Page 1 of 4

Previous Screen

Product: TELEHANDLER
Model: TH360B TELEHANDLER SLE
Configuration: TH355B TH360B Telehandler SLE00001-UP (MACHINE) POWERED BY 3054E Engine

Troubleshooting
TH220B, TH330B, TH340B, TH350B, TH355B, TH360B, TH460B, TH560B and TH580B
Telehandlers
Media Number -RENR5195-06 Publication Date -01/10/2009 Date Updated -20/10/2009

i03717725

MID 039 - CID 0246 - FMI 12


SMCS - 7610-038-MCH

Part Number S/N


- SLB1-1499

Part Number S/N


- SLD1-1399

Part Number S/N


- JRK1-UP

Part Number S/N


- SLF1-2099

Part Number S/N


- SLG1-1299

Part Number S/N


- SLA1-849

Part Number S/N


- SLE1-4499

Part Number S/N


- SLC1-849

Part Number S/N


- SLH1-899

Conditions Which Generate This Code:

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 13/09/2020
TH355B TH360B Telehandler SLE00001-UP (MACHINE) POWERED BY 3054E E... Page 2 of 4

Illustration 1 g02003076

Schematic of the CAN A data link for the Programmable Hydraulic System (PHS)

This diagnostic code is recorded when the PHS does not receive expected information from the machine
ECM for a period of more than five seconds.

System Response:

This failure results in events that are logged against an ECM that can not be explained directly. The PHS
cannot communicate with the machine ECM or the ECM appears to communicate intermittently. Prior to
performing this procedure, check for an active diagnostic code of CID 0246 FMI 12.

Test Step 1. INSPECT THE HARNESS CONNECTORS.

A. Turn the key start switch and the disconnect switch to the OFF position.

B. Inspect the connections of the machine harness that are related to the CAN A data link.

C. Make sure that connectors are clean and tight.

Expected Result:

The machine harness is correct.

Results:

• OK - The machine harness is correct. Proceed to test step 2.

• NOT OK - The machine harness is not correct.

Repair: Repair the machine harness or replace the machine harness.

STOP

Test Step 2. CHECK FOR A SHORT TO GROUND.

A. The key start switch and the disconnect switch remain in the OFF position.

B. Disconnect the machine harness from all electronic control modules that use the CAN A data link.

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 13/09/2020
TH355B TH360B Telehandler SLE00001-UP (MACHINE) POWERED BY 3054E E... Page 3 of 4

C. At the machine harness connector for the ECM, measure the resistance between frame ground and the
CAN A data link circuits (contacts J2-67 and J2-68).

Expected Result:

The resistance measurement should be greater than 5000 ohms.

Results:

• YES - The resistance is less than 5000 ohms.

Repair: The machine harness has failed. There is a short between frame ground and the CAN A data
link circuit in the machine harness. Repair the machine harness or replace the machine harness.

STOP

• NO - The resistance is greater than 5000 ohms. The harness circuit resistance is correct. Proceed to
test step 3.

Test Step 3. CHECK FOR A SHORT TO THE +BATTERY CIRCUIT.

A. The key start switch and the disconnect switch remain in the OFF position.

B. All related control modules remain disconnected from the machine harness.

C. At the harness for the ECM, measure the resistance between the +battery circuit (contact J1-38)(wire
111-RD) and the supply voltage (contact J1-69)(wire 799-WH).

Expected Result:

The resistance is greater than 5000 ohms.

Results:

• OK - The resistance is greater than 5000 ohms. The harness circuit resistance is correct. Proceed to
test step 4.

• NOT OK - The resistance is less than 5000 ohms.

Repair: The harness has failed. There is a short between the +battery contact and the CAN A data
link circuit in the machine harness. Repair the machine harness or replace the machine harness.

STOP

Test Step 4. CHECK FOR AN OPEN HARNESS.

A. The key start switch and the disconnect switch remains in the OFF position.

B. All related control modules remain disconnected from the machine harness.

C. Check the continuity of the CAN A data link circuit in the machine harness.

D. Measure the resistance from contacts J2-67 and J2-68 of the machine ECM. Measure the resistance to
the corresponding contacts of each related electronic control module.

Expected Result:

The resistance measurement is less than 5 ohms.

Results:

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 13/09/2020
TH355B TH360B Telehandler SLE00001-UP (MACHINE) POWERED BY 3054E E... Page 4 of 4

• YES - The resistance measurement is less than 5 ohms.

Repair: The CAN A data link circuit in the machine harness is correct. The ECM has failed. It is
unlikely that the ECM has failed. Exit this procedure and perform this procedure for the diagnostic
code again. Replace the ECM if the cause of the diagnostic code is NOT found. See Testing and
Adjusting, "Electronic Control Module (ECM) - Replace".

STOP

• NO - The resistance is greater than 5 ohms.

Repair: The machine harness has failed. The CAN A data link circuit is open in the machine harness.
Repair the machine harness or replace the machine harness.

STOP

Copyright 1993 - 2020 Caterpillar


Inc.
All Rights Reserved.
Private Network For SIS Licensees.
Sun Sep 13 18:30:43 UTC+1000