RTT Standardisierung
RTT Standardisierung
RTT Standardisierung
C2 General
C2 General
Main Challenges & Approach
RTT Standardization is an opportunity to bring operational efficiencies and reduce dependencies on 3rd parties and control
infrastructure costs.
Main Challenges How are we doing it?
Patternless Fit for Single Purpose RTT structures Cataloged Site Design
Case–by-case site design leads to multiple structure types, variable Well-defined structure selection method creates a unified approach for
heights and custom-made solutions. Irregular statical calculation for the RTT site designs. Design offices to adopt Eurocode compliant
different structures from different Design offices. models and the respective component inventory enabling improved
control over the general site design.
High CW deployment complexity & Roof Diversity Reduce Deployment times & Construction Errors Mitigation
Rooftop sites bring specific challenges making each one a tailored Pre-defined part types and common connections will increase the ease
design/structure created to fulfill the demands of radio and of construction and reduce installation errors. Standard installation
maintenance of the building fabrics. guidelines simplifies handling and maintenance of steel structures.
RTT Standardization is intended to be a “one library fits all” approach thus securing flexibility and adaptability to
different roof types and site configurations.
C2 General 2
C2 General
RTT Standardization – Variables Analysis
1 Process efficiency 2 Ordering 3 Risks
• Every Site has unique items • Long lead times due to • High Quality Risks due to
and need to be handled as a step-by-step ordering site based construction
single case site Solution according Milestones
• Small missing parts can
• 3 rd
Party items cause a • No possible Forecast of cause a site build stop and
longer lead time for Material usage possible. spare parts need to be
Purchase Order and more Dependency on 3rd Party produced site based and
approval stages delivery time cause delay
Multipoles Monopole
Category 1 Category 2 Category 2b Category 3 Category 4 Category 4b
Support: Wall-mounted Support: Flat Roof Support: Flat Roof Support: Flat Roof / Pitched Roof Support: Pitched Roof Support: Pitched Roof
Application: Distributed Wall- Application: Distributed Flat Roof Application: Distributed Flat Roof Application: Centralized Flat Roof Application: Centralized Pitched Application: Centralized Pitched
mounted Roof Roof
Design Exposed Area: Design Exposed Area: Design Exposed Area: Design Exposed Area: Design Exposed Area: Design Exposed Area:
• 4.45m² @ 0.75[kN/m²] • 4.77m² @ 0.75[kN/m²] • 4.77m² @ 0.75[kN/m²] • 9.36m² @ 0.75[kN/m²] • 3.37m² @ 0.75[kN/m²] • 3.37m² @ 0.75[kN/m²]
• 3.34m² @ 1.00[kN/m²] • 3.58m² @ 1.00[kN/m²] • 3.58m² @ 1.00[kN/m²] • 7.02m² @ 1.00[kN/m²] • 2.53m² @ 1.00[kN/m²] • 2.53m² @ 1.00[kN/m²]
• 2.67m² @ 1.25 [kN/m²] • 2.86m² @ 1.25 [kN/m²] • 2.86m² @ 1.25 [kN/m²] • 5.62m² @ 1.25 [kN/m²] • 2.02m² @ 1.25 [kN/m²] • 2.02m² @ 1.25 [kN/m²]
C2 General 4
C2 General
Standardized RTT Catalogue Details (1/2)
All standardized structures consolidated in a certified catalog
RTT Structure Categories
Distributed Multipoles Monopole
Cat.1 Cat.2 Cat.2b Cat.3 Cat.4 Cat.4b
General Atributes
Height [m] 2m / 4m 3m / 6m 4m / 7m / 10m 4m / 7m / 10m 6m / 8m / 10m 6m / 8m / 10m
Distribution type Multipole Multipole Multipole Monopole Monopole Monopole
Support type Wall-Mounted Flat Roof Flat Roof Flat Roof Pitched Roof Pitched Roof
Support frame shape N/A L shape L shape X shape N/A N/A
Min: 2.435 x 2.435 Min: 3.850 x 3.850 Min: 5.32 x 5.32 Min: 2.15 x 2.15
Horizontal footprint [m²] 1.00 x 1.00* 1.00 x 1.00**
Max: 5.265 x 5.265 Max: 5.265 x 5.265 Max: 7.41 x 7.41 Max: 7.00 x 7.00
Wind pressure of 0.75 [kN/m²] 4,45 4,77 4,77 9,36 3,37 3,37
Wind pressure of 1.00 [kN/m²] 3,34 3,58 3,58 7,02 2,53 2,53
Wind pressure of 1.25 [kN/m²] 2,67 2,86 2,86 5,62 2,02 2,02
Material
Maximum Steel Weight [kg] 191 537 804 1,577 489 607
3,37
Pitched Roof Category 4/4b 2,53
2,02
9,36
Category 3 7,02
5,62 Legend:
Flat Wind pressure of 0.75 [kN/m²]
Roof
4,77 Wind pressure of 1.00 [kN/m²]
Category 2/2b 3,58
Wind pressure of 1.25 [kN/m²]
2,86
4,45
Wall Mounted Category 1 3,34
2,67
0 1 2 3 4 5 6 7 8 9 10
Design Exposed Area [m²]
KEY NOTES:
• This chart works as a reference guideline to assist the decision of the structural category to be adopted for a specific site, depending on the Design Exposed
Area and Roof Type
• This chart was defined for a reference values of Wind Pressure value, implying that for different Wind Pressure value, the Category chosen may be altered
C2 General 6
C2 General
Standardized RTT Catalogue Details (1/2)
All standardized structures consolidated in a certified catalog
RTT Technique Frame is
designed to support the
Equipment Installation on a
Rooftop Site .
Modular System
C2 General
C2 General
Sample Document
Szenario 1
https://tconglobal.com/wp-content/uploads/2020/03/rethinkingstandardization_blog_image.jpg
C2 General
C2 General
RTT Standardization – Trial Sites Status
Out of 20 Candidates 3 are in the
nearly build phase and the steel
ordering process has started
Next Steps :
- Steel pre-order
- Receive BnetzA approval for site
build
https://tconglobal.com/wp-content/uploads/2020/03/rethinkingstandardization_blog_image.jpg
C2 General
C2 General
Next Steps
1 Trial Sites 2 Processes 3 Documentation
• Implement the new parts for • Final Implement the new • Provide site selection
the Categories into the SKU process into the Acquisition criteria Guide to support
process scope Design Partner for selection
C2 General
C2 General