PURPOSE: To determine ventilation requirements in order to eliminate, reduce or control any space-specific and/or work-introduced
contaminants
Saudi Aramco: Company General Use LP – T&I BP - Confined Space Ventilation Requirements - Form - v2 – March 2022
CONFINED SPACE VENTILATION REQUIREMENTS – BEST PRACTICE
VENTILATIO □ Natural ventilation (warning: not to be used as single means for PURPOSE OF □ Initial purging of space-specific
N TYPES TO initial purging and/or control/removal of airborne contaminants) VENTILATION: contaminants
BE USED: (Select all that apply)
□ Mechanical □ Control/removal of worked-introduced
(Select all that
□ Forced □ Draft □ Local exhaust/extraction contaminants
apply)
□ All of the above □ Comfort / cooling
□ All of the above
TOTAL VENTILATION VOLUME OF CONFINED SPACE SELECT REQUIRED AIR MOVER CAPACITY
REQUIREMENTS (RAMC) REMARKS
(with known confined M3 bbl l/sec CFM
space volume, select 16 100 □ 472 □ 1,000
RAMC. Add a 20-25%
80 500 □ 1,180 □ 2,500
correction factor for
air flow losses due to 160 1,000 □ 2,360 □ 5,000
internals. Round up to 800 5,000 □ 4,720 □ 10,000
the next RAMC figure)
1,600 10,000 □ 7,080 □ 15,000
(1) ≥ 4,000 ≥ 25,000 □ 9,440 □ 20,000
TYPICAL AIR 24” Jet Fans 10” Venturi type
MOVERS
CAPACITIES
(for the
selected Compressed Air Pressure Free Air Flow RPM Decibel Levels Compressed Air Pressure Free Air Flow Decibel Levels
RAMC, select (psi / bar) (CFM / M3/Hr) (@ 5 ft) (psi / bar) (CFM / M3/Hr) (@ 5 ft)
type and 40 / 2.75 8,104 / 13,769 1,565 92 40 / 2.75 4,898 / 8,321 76
number of Air 60 / 4.14 11,005 / 18,698 2,053 95 60 / 4.14 6,182 / 10,503 81
80 / 5.52 12,848 / 21,829 2,570 100 80 / 5.52 7,304 / 12,409 83
Mover(s) to
100 / 6.89 16,136 / 27, 415 3,138 112 100 / 6.89 8,220 / 13,965 85
meet
ventilation
requirements)
.
(2)
TYPE & □ Jet fans ______ Size: ____ Locations: ______________________ □ Fans □ Flexible ducts □ Flexible
NUMBER OF □ Venturis _2____ Size: __8”_ Locations: ________________________ OTHER AUXILIARY
AIR MOVERS Remarks: EQUIPMENT elbows □ Air chillers □
TO MEET ___________________________________________________ REQUIRED Saddle vents □ Air screens □ Other:
RAMC Note: Jet fans can be conveniently installed for either forced or draft (Select all that apply)
ventilation. ___________________
Saudi Aramco: Company General Use LP – T&I BP - Confined Space Ventilation Requirements - Form - v2 – March 2022
CONFINED SPACE VENTILATION REQUIREMENTS – BEST PRACTICE
Saudi Aramco: Company General Use LP – T&I BP - Confined Space Ventilation Requirements - Form - v2 – March 2022