The document contains calculations for selecting pipe sizes for two different flow rates. For a total flow of 1699.2 m3/hr, a pipe with an inner diameter of 207.2393174 mm (DN 250 UPVC) was selected. For a total flow of 1280.7 m3/hr, a pipe with an inner diameter of 179.917583 mm (DN 200 UPVC) was selected. Both selections were based on achieving an average velocity of 14 m/s for odour flow.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
65 views3 pages
Pipe Size Calculator
The document contains calculations for selecting pipe sizes for two different flow rates. For a total flow of 1699.2 m3/hr, a pipe with an inner diameter of 207.2393174 mm (DN 250 UPVC) was selected. For a total flow of 1280.7 m3/hr, a pipe with an inner diameter of 179.917583 mm (DN 200 UPVC) was selected. Both selections were based on achieving an average velocity of 14 m/s for odour flow.