Pressure Switches Hex 24 With Integrated Connector M.1

The document discusses pressure switches with integrated connectors that have: - Setting ranges up to 50 bar and maximum voltages up to 42V. - Compact and rugged zinc-plated steel designs suitable for industrial environments. - Integrated connector options from various manufacturers that allow for quick attachment and reliable connections with IP67 protection.

Uploaded by

Rodica Puscau
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
26 views10 pages

Pressure Switches Hex 24 With Integrated Connector M.1

The document discusses pressure switches with integrated connectors that have: - Setting ranges up to 50 bar and maximum voltages up to 42V. - Compact and rugged zinc-plated steel designs suitable for industrial environments. - Integrated connector options from various manufacturers that allow for quick attachment and reliable connections with IP67 protection.

Uploaded by

Rodica Puscau
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

M.

1 Pressure switches hex 24


hex 24 integrated
with integrated connector
NC or NO, maximum operating voltage up to 42 V

• Large selection of electrical plug-in types for quick


attachment and reliable connection

• High protection class (to IP67 or IP6K9K)

• Compact and rugged design in industrial environments


like construction and agricultural machinery or commercial
vehicles

• Switching point can be set on site with adjusting screw in the


connector1)

• High overpressure resistance, compact, small switches,


available as normally open or normally closed

• Vacuum switches with integrated connector available on request

1)
Pressure switches can also be supplied preset at factory.
22 The switching point is embossed onto pressure switches preset at factory.
The all-rounder
with the broad selection of options
NC or NO, maximum operating voltage up to 42 V

with 10 plug-in types


Deutsch
DT04-2P
M12x1 with 3 codings Bayonet with 4 codings
Coding: PIN 1+3 Coding: PIN 1+4 Coding A1-2.1 Coding A2-2.1

Coding: PIN 1+2 Coding A3-2.1 Coding A4-2.1


AMP
Superseal 1.5®

Packard
MetriPack 280® M

for 7 setting ranges


0.1 – 1 bar

0.5 – 3 bar
Deutsch
DT04-3P 1 – 10 bar

10 – 20 bar
20 – 50 bar

50 – 150 bar
with many
thread types 100 – 200 bar
AMP
Junior Timer®
G 1/4
Suitable for a broad
diversity of applications
G 1/8
• NBR Hydraulic/machine oil,
M 10x1 cyl. air, nitrogen, etc.
• EPDM Brake fluid, hydrogen,
Bayonet oxygen, acetylene, etc.
M 10x1 con. • FKM Hydraulic fluids (HFA, HFB,
DIN 72585
HFD), petrol/gasoline, etc.
M 12x1.5 cyl. • FFKM Hot water, chemical acids,
diluted alkalis, ketones,
NPT 1/8 esters, alcohols
• HNBR Hydraulic/machine oil,
esterbased bio-oils
NPT 1/4
• Silicone Water, food products
M12x1 DIN EN (FDA approval)
9/16-18 UNF
61076-2-101-A
7/16-20 UNF 23
M.1 Pressure switches hex 24
hex 24 integrated
with integrated connector
Technical details

0110 / 0111 Rated working voltage: 10 … 42 VAC/DC


Deutsch Rated current range 10 mA … 4 A
DT04-2P (resistive load, DC12 / AC12):
IP67, IP6K9K Switching power DC12 / AC12: 100 W / 100 VA

NBR
-40 °C … +100 °C
(diaphragm pressure switch)
0112 / 0113
NBR
AMP -30 °C … +100 °C
(piston pressure switch)
Superseal 1.5®
EPDM -30 °C … +120 °C
IP67
Temperature resistance FKM
-5 °C … +120 °C
of sealing materials: (diaphragm pressure switch)

0114 / 0115 FKM


-15 °C … +120 °C
(piston pressure switch)
Packard
MetriPack 280® FFKM -20 °C … +120 °C
IP67 Silicone -40 °C … +120 °C

HNBR -30 °C … +120 °C


0116 / 0117 Burst pressure
(diaphragm pressure switch): 400 bar
Deutsch
DT04-3P Burst pressure 700 bar (for threads M10, G 1/8, R 1/8 and NPT 1/8 up to max. 600 bar)
(piston pressure switch)
IP67, IP6K9K Switching frequency: 200 / min

1,000,000 cycles (for diaphragm pressure switches, life expectancy


Mechanical life expectancy:
0118 / 0119 value only applies for switching pressures to max. 50 bar)

AMP Pressure rise rate: ≤ 1,000 bar/s


Junior Timer®
Hysteresis: Average value 5…30 % depending on type, not adjustable
IP65, IPx4K
Vibration resistance: 10 g; 5…200 Hz sine wave, DIN EN 60068-2-6

Shock resistance: 294 m/s2; 14 ms half sine wave; DIN EN 60068-2-27


0120 / 0121
Bayonet Up to IP67 / IP6K9K according to manufacturer‘s specifications
Protection class: for the respective plug-in system only when plugged in,
DIN 72585 otherwise IP00
IP67, IP6K9K Weight: approx. 90 g

Contact assignment for bayonet connectors


0122 / 0123
M12x1 DIN EN Coding A1-2.1 Coding A2-2.1 Coding A3-2.1 Coding A4-2.1
61076-2-101-A
IP67

0124 / 0125
1 1 1 1
M12x1 DIN EN
60947-5-2

24 IP67 2 2 2 2
0110 / 0112 / 0114 / 0116 / 0118 / 0122 / 0124 M.1
Diaphragm pressure switches with integrated connector hex 24 integrated

 Setting ranges to up to 50 bar (higher settings refer to page 26)


 NC or NO, maximum voltage 42 V
 Zinc-plated steel (Cr VI-free)
 Overpressure safety up to 300 bar1)

Plug-in types for diaphragm pressure switches


Deutsch DT04-2P 0110 - XXX XX - X - XXX 0110 - XXX XX - X - XXX
AMP Superseal 1.5® 0112 - XXX XX - X - XXX 0112 - XXX XX - X - XXX
See
Packard MetriPack 280® 0114 - XXX XX - X - XXX 0114 - XXX XX - X - XXX table for
plug-in
Deutsch DT04-3P 0116 - XXX XX - X - XXX 0116 - XXX XX - X - XXX types

Refer to page 30/31 for height


page 23
AMP Junior Timer® 0118 - XXX XX - X - XXX 0118 - XXX XX - X - XXX
M12x1 DIN EN 61076-2-101-A (PIN 1+3) 0122 - XXX XX - X - XXX 0122 - XXX XX - X - XXX
M12x1 DIN EN 60947-5-2 (PIN 1+2 / PIN 1+4) 0124 - XXX XX - X - XXX 0124 - XXX XX - X - XXX

Adjustment range Male hex 24


Article number Article number
(Tolerance at room temperature) thread NO —› |: NC —› :|

Diaphragm pressure switches with integrated connector 9

G 1/4 XXXX - 403 03 - X - 011 XXXX - 404 03 - X - 015


G 1/8 XXXX - 403 28 - X - 603 XXXX - 404 28 - X - 604
M 10x1 cyl. XXXX - 403 13 - X - 003 XXXX - 404 13 - X - 004
0.1 - 1 (± 0.2) bar
M 10x1 con. XXXX - 403 01 - X - 009 XXXX - 404 01 - X - 013 M
M 12x1.5 cyl. XXXX - 403 02 - X - 010 XXXX - 404 02 - X - 014
NPT 1/8 XXXX - 403 04 - X - 012 XXXX - 404 04 - X - 016

G 1/4 XXXX - 423 03 - X - 070 XXXX - 424 03 - X - 070


G 1/8 XXXX - 423 28 - X - 070 XXXX - 424 28 - X - 070
M 10x1 cyl. XXXX - 423 13 - X - 070 XXXX - 424 13 - X - 070
0.5 - 3 (± 0.3) bar
M 10x1 con. XXXX - 423 01 - X - 070 XXXX - 424 01 - X - 070
M 12x1.5 cyl. XXXX - 423 02 - X - 070 XXXX - 424 02 - X - 070
NPT 1/8 XXXX - 423 04 - X - 070 XXXX - 424 04 - X - 070

G 1/4 XXXX - 407 03 - X - 027 XXXX - 408 03 - X - 031


G 1/8 XXXX - 407 28 - X - 607 XXXX - 408 28 - X - 608
M 10x1 cyl. XXXX - 407 13 - X - 007 XXXX - 408 13 - X - 008
1 - 10 (± 0.5) bar
M 10x1 con. XXXX - 407 01 - X - 025 XXXX - 408 01 - X - 029
M 12x1.5 cyl. XXXX - 407 02 - X - 026 XXXX - 408 02 - X - 030
NPT 1/8 XXXX - 407 04 - X - 028 XXXX - 408 04 - X - 032

Seal material – Application areas


NBR Hydraulic/machine oil, air, nitrogen, etc. 1
EPDM Brake fluid, hydrogen, oxygen, acetylene, etc. 2
FKM Hydraulic fluids (HFA, HFB, HFD), petrol/gasoline, etc. 3
FFKM Hot water, chemical acids, diluted alkalis, ketones, esters, alcohols 6
HNBR Hydraulic/machine oil, ester-based bio-oils 9
Refer to page 24 for the temperature range and application thresholds of sealing materials.

Article number: 01XX – XXX XX – X – XXX

RoHSII
1)
Static value. Dynamic value is 30-50 % lower. Values pertain to the hydraulic/pneumatic part of the pressure switch. compliant
25
M.1 0110 / 0112 / 0114 / 0116 / 0118 / 0122 / 0124
hex 24 integrated Diaphragm pressure switches with integrated connector

 Setting ranges up to 50 bar (lower settings refer to page 25)


 NC or NO, maximum operating voltage up to 42 V
 Zinc-plated steel (Cr VI-free)
 Overpressure safety up to 300 bar1)

Plug-in types for diaphragm pressure switches


Deutsch DT04-2P 0110 - XXX XX - X - XXX 0110 - XXX XX - X - XXX
AMP Superseal 1.5® 0112 - XXX XX - X - XXX 0112 - XXX XX - X - XXX
See table
for plug-in Packard MetriPack 280® 0114 - XXX XX - X - XXX 0114 - XXX XX - X - XXX
types
Refer to page 30/31 for height

page 23 Deutsch DT04-3P 0116 - XXX XX - X - XXX 0116 - XXX XX - X - XXX


AMP Junior Timer® 0118 - XXX XX - X - XXX 0118 - XXX XX - X - XXX
M12x1 DIN EN 61076-2-101-A (PIN 1+3) 0122 - XXX XX - X - XXX 0122 - XXX XX - X - XXX
M12x1 DIN EN 60947-5-2 (PIN 1+2 / PIN 1+4) 0124 - XXX XX - X - XXX 0124 - XXX XX - X - XXX

hex 24
Adjustment range Male Article number Article number
(tolerance at room temperature) thread NO —› |: NC —› :|

9
Diaphragm pressure switches with integrated connector
G 1/4 XXXX - 411 03 - X - 043 XXXX - 412 03 - X - 047

0122 Coding: PIN 1+3 G 1/8 XXXX - 411 28 - X - 611 XXXX - 412 28 - X - 612
M 10x1 cyl. XXXX - 411 13 - X - 011 XXXX - 412 13 - X - 012
10 - 20 (± 1) bar
M 10x1 con. XXXX - 411 01 - X - 041 XXXX - 412 01 - X - 045
M 12x1.5 cyl. XXXX - 411 02 - X - 042 XXXX - 412 02 - X - 046
NPT 1/8 XXXX - 411 04 - X - 044 XXXX - 412 04 - X - 048

G 1/4 XXXX - 415 03 - X - 059 XXXX - 416 03 - X - 063


G 1/8 XXXX - 415 28 - X - 615 XXXX - 416 28 - X - 616
M 10x1 cyl. XXXX - 415 13 - X - 015 XXXX - 416 13 - X - 016
0124 Coding: PIN 1+4 (NO) 20 - 50 (± 2) bar
M 10x1 con. XXXX - 415 01 - X - 057 XXXX - 416 01 - X - 061
M 12x1.5 cyl. XXXX - 415 02 - X - 058 XXXX - 416 02 - X - 062
NPT 1/8 XXXX - 415 04 - X - 060 XXXX - 416 04 - X - 064

Seal material – Application areas


NBR Hydraulic/machine oil, air, nitrogen, etc. 1
EPDM Brake fluid, hydrogen, oxygen, acetylene, etc. 2
FKM Hydraulic fluids (HFA, HFB, HFD), petrol/gasoline, etc. 3
0124 Coding: PIN 1+2 (NC)
FFKM Hot water, chemical acids, diluted alkalis, ketones, esters, alcohols 6
HNBR Hydraulic/machine oil, ester-based bio-oils 9
Refer to page 24 for the temperature range and application thresholds of sealing materials.

Article number: 01XX – XXX XX – X – XXX

RoHSII
26 compliant 1)
Static value. Dynamic value is 30-50 % lower. Values pertain to the hydraulic/pneumatic part of the pressure switch.
0111 / 0113 / 0115 / 0117 / 0119 / 0123 / 0125 M.1
Piston pressure switches with integrated connector hex 24 integrated

 Setting range up to 150 bar


 NC or NO, maximum operating voltage up to 42 V
 Zinc-plated steel (Cr VI-free)
 Overpressure safety up to 600 bar1)

Plug-in types for piston pressure switches


Deutsch DT04-2P 0111 - XXX XX - X - XXX 0111 - XXX XX - X - XXX
AMP Superseal 1.5® 0113 - XXX XX - X - XXX 0113 - XXX XX - X - XXX See table
for plug-in
Packard MetriPack 280® 0115 - XXX XX - X - XXX 0115 - XXX XX - X - XXX types
page 23

Refer to page 30/31 for height


Deutsch DT04-3P 0117 - XXX XX - X - XXX 0117 - XXX XX - X - XXX
AMP Junior Timer® 0119 - XXX XX - X - XXX 0119 - XXX XX - X - XXX
M12x1 DIN EN 61076-2-101-A (PIN 1+3) 0123 - XXX XX - X - XXX 0123 - XXX XX - X - XXX
M12x1 DIN EN 60947-5-2 (PIN 1+2 / PIN 1+4) 0125 - XXX XX - X - XXX 0125 - XXX XX - X - XXX

hex 24
Adjustment range Male Article number Article number
(tolerance at room temperature) thread NO —› |: NC —› :|

9
Piston pressure switches with integrated connector
G 1/4 XXXX - 419 03 - X - 011 XXXX - 420 03 - X - 015
G 1/8 XXXX - 419 28 - X - 603 XXXX - 420 28 - X - 604
0123 Coding: PIN 1+3
M 10x1 cyl. XXXX - 419 13 - X - 003 XXXX - 420 13 - X - 004
50 - 150 (± 5) bar M
M 10x1 con. XXXX - 419 01 - X - 009 XXXX - 420 01 - X - 013
M 12x1.5 cyl. XXXX - 419 02 - X - 010 XXXX - 420 02 - X - 014
NPT 1/8 XXXX - 419 04 - X - 012 XXXX - 420 04 - X - 016

G 1/4 DIN 3852-2-A XXXX - 493 60 - X - 011 XXXX - 494 60 - X - 015


100 - 200 (± 5) bar
M 12x1.5 DIN 3852-1-A XXXX - 493 68 - X - 010 XXXX - 494 68 - X - 014

Seal material – Application areas 0125 Coding: PIN 1+4 (NO)


NBR Hydraulic/machine oil, air, nitrogen, etc. 1
EPDM Brake fluid, hydrogen, oxygen, acetylene, etc. 2
FKM Hydraulic fluids (HFA, HFB, HFD), petrol/gasoline, etc. 3
HNBR Hydraulic/machine oil, ester-based bio-oils 9
Refer to page 24 for the temperature range and application thresholds of sealing materials.

Article number: 01XX – XXX XX – X – XXX


0125 Coding: PIN 1+2 (NC)

RoHSII
compliant
1)
Static value. Dynamic value is 30-50 % lower. Values pertain to the hydraulic/pneumatic part of the pressure switch. 27
M.1 0120
hex 24 integrated Diaphragm pressure switches with integrated bayonet connector

 NC or NO, maximum operating voltage up to 42 V


 Zinc-plated steel (Cr VI-free)
 Overpressure safety up to 300 bar1)

Adjustment range male Article number Article number


(tolerance at room temperature) thread NO —› |: NC —› :|
Bayonet ISO 15170
(DIN 72585)
0120 Diaphragm pressure switches with integrated connector

G 1/4 0120 - X03 03 - X - 011 0120 - X04 03 - X - 015


G 1/8 0120 - X03 28 - X - 603 0120 - X04 28 - X - 604
M 10x1 cyl. 0120 - X03 13 - X - 003 0120 - X04 13 - X - 004
0.1 - 1 (± 0.2) bar
M 10x1 con. 0120 - X03 01 - X - 009 0120 - X04 01 - X - 013
M 12x1.5 cyl. 0120 - X03 02 - X - 010 0120 - X04 02 - X - 014
49

NPT 1/8 0120 - X03 04 - X - 012 0120 - X04 04 - X - 016

hex 24 G 1/4 0120 - X23 03 - X - 070 0120 - X24 03 - X - 070


G 1/8 0120 - X23 28 - X - 070 0120 - X24 28 - X - 070
M 10x1 cyl. 0120 - X23 13 - X - 070 0120 - X24 13 - X - 070
9 0.5 - 3 (± 0.3) bar
M 10x1 con. 0120 - X23 01 - X - 070 0120 - X24 01 - X - 070
M 12x1.5 cyl. 0120 - X23 02 - X - 070 0120 - X24 02 - X - 070
NPT 1/8 0120 - X23 04 - X - 070 0120 - X24 04 - X - 070

G 1/4 0120 - X07 03 - X - 027 0120 - X08 03 - X - 031


G 1/8 0120 - X07 28 - X - 607 0120 - X08 28 - X - 608
M 10x1 cyl. 0120 - X07 13 - X - 007 0120 - X08 13 - X - 008
1 - 10 (± 0.5) bar
M 10x1 con. 0120 - X07 01 - X - 025 0120 - X08 01 - X - 029
M 12x1.5 cyl. 0120 - X07 02 - X - 026 0120 - X08 02 - X - 030
NPT 1/8 0120 - X07 04 - X - 028 0120 - X08 04 - X - 032

Coding
A1 - 2 . 1 4XX 4XX
A2-2.1 3XX 3XX
A3-2.1 2XX 2XX
A4-2.1 1XX 1XX

Seal material – Application areas


NBR Hydraulic/machine oil, air, nitrogen, etc. 1
EPDM Brake fluid, hydrogen, oxygen, acetylene, etc. 2
FKM Hydraulic fluids (HFA, HFB, HFD), petrol/gasoline, etc. 3
FFKM Hot water, chemical acids, diluted alkalis, ketones, esters, alcohols 6
HNBR Hydraulic/machine oil, ester-based bio-oils 9
Refer to page 24 for the temperature range and application thresholds of sealing materials.

Article number: 0120 – XXX XX – X – XXX

RoHSII
compliant
28 1)
Static value. Dynamic value is 30-50 % lower. Values pertain to the hydraulic/pneumatic part of the pressure switch.
0120 / 0121 M.1
Diaphragm/piston pressure switches with integrated bayonet hex 24 integrated
 NC or NO, maximum operating voltage up to 42 V
 Zinc-plated steel (Cr VI-free)
 Diaphragm variant: Overpressure safety up to 300 bar1)

 Piston variant: Overpressure safety up to 600 bar1)

Adjustment range male Article number Article number


(tolerance at room temperature) thread NO —› |: NC —› :|

0120 Diaphragm pressure switches with integrated connector Coding A1-2.1


G 1/4 0120 - X11 03 - X - 043 0120 - X12 03 - X - 047
G 1/8 0120 - X11 28 - X - 611 0120 - X12 28 - X - 612
M 10x1 cyl. 0120 - X11 13 - X - 011 0120 - X12 13 - X - 012
10 - 20 (± 1) bar
M 10x1 con. 0120 - X11 01 - X - 041 0120 - X12 01 - X - 045
M 12x1.5 cyl. 0120 - X11 02 - X - 042 0120 - X12 02 - X - 046
NPT 1/8 0120 - X11 04 - X - 044 0120 - X12 04 - X - 048

G 1/4 0120 - X15 03 - X - 059 0120 - X16 03 - X - 063 Coding A2-2.1


G 1/8 0120 - X15 28 - X - 615 0120 - X16 28 - X - 616
M 10x1 cyl. 0120 - X15 13 - X - 015 0120 - X16 13 - X - 016
20 - 50 (± 2) bar
M 10x1 con. 0120 - X15 01 - X - 057 0120 - X16 01 - X - 061
M 12x1.5 cyl. 0120 - X15 02 - X - 058 0120 - X16 02 - X - 062
NPT 1/8 0120 - X15 04 - X - 060 0120 - X16 04 - X - 064
M
0121 Piston pressure switches with integrated connector
G 1/4 0121 - X19 03 - X - 011 0121 - X20 03 - X - 015
Coding A3-2.1
G 1/8 0121 - X19 28 - X - 603 0121 - X20 28 - X - 604
M 10x1 cyl. 0121 - X19 13 - X - 003 0121 - X20 13 - X - 004
50 - 150 (± 5) bar
M 10x1 con. 0121 - X19 01 - X - 009 0121 - X20 01 - X - 013
M 12x1.5 cyl. 0121 - X19 02 - X - 010 0121 - X20 02 - X - 014
NPT 1/8 0121 - X19 04 - X - 012 0121 - X20 04 - X - 016

G 1/4 DIN 3852-2-A 0121 - X93 60 - X - 011 0121 - X94 60 - X - 015


100 - 200 (± 5) bar
M 12x1.5 DIN 3852-1-A 0121 - X93 68 - X - 010 0121 - X94 68 - X - 014

Coding Coding A4-2.1


A1 - 2 . 1 4XX 4XX
A2-2.1 3XX 3XX
A3-2.1 2XX 2XX
A4-2.1 1XX 1XX

Seal material – Application areas


NBR Hydraulic/machine oil, air, nitrogen, etc. 1
EPDM Brake fluid, hydrogen, oxygen, acetylene, etc. 2
FKM Hydraulic fluids (HFA, HFB, HFD), petrol/gasoline, etc. 3
FFKM Hot water, chemical acids, diluted alkalis, ketones, esters, alcohols 6
HNBR Hydraulic/machine oil, ester-based bio-oils 9
Refer to page 24 for the temperature range and application thresholds of sealing materials.

Article number: 012X – XXX XX – X – XXX

RoHSII
1)
Static value. Dynamic value is 30-50 % lower. Values pertain to the hydraulic/pneumatic part of the pressure switch.
compliant 29
M.1 Technical details,
hex 24 integrated
contact assignment & accessories
for hex 24 pressure switches with integrated connector

Mating plug accessories 1)

Please note: Mating plug


Deutsch DT04-2P AMP Packard
Mating plugs are type
(for DT06-2S) Superseal 1.5® MetriPack 280®
not included in the
Including 2 m
delivery and can be cable
ordered separately.

Cable cross-
2 x 0,5 mm² Radox cables 2 x 0,5 mm² Radox cables 2 x 0,5 mm² Radox cables
section
Protection class IP65 IP65 IP65

Article number 1-1-10-653-118 1-1-12-653-113 1-1-14-653-114


1)
For the pin assignment of the wires please refer to chapter M.10 Accessories (page 91)

Plug-in types for hex 24 diaphragm and piston pressure switches

Model / Type 0110 / 0111 0112 / 0113 0114 / 0115

Deutsch AMP Packard


Connector
DT04-2P Superseal 1.5® MetriPack 280®
Protection class IP67, IP6K9K IP67 IP67

Overall height H ≈ 61 mm H ≈ 61 mm H ≈ 62 mm
Contact
assignment

1 2 1 2 A B

30
Bayonet
Deutsch DT04-3P AMP M12x1 DIN EN 61076-2-101-LF (A)
DIN 72585/ISO 15170
(for DT04-3P) Junior Timer®
A1 - 2.1

2 x 0,5 mm² PUR cables 2 x 0,5 mm² Radox cables 2 x 0,5 mm² Radox cables 4 x 0.34 mm² PUR cables

IP67 IP65 IP65 IP67


M
1-1-36-653-160 1-1-18-653-116 1-1-20-653-112 1-1-00-653-162

0116 / 0117 0118 / 0119 0120 / 0121 0122 / 0123 0124 / 0125

0.18 mm 0.25 mm 0.35 mm

Deutsch AMP Bayonet M12x1 DIN EN M12x1 DIN EN


DT04-3P Junior Timer® DIN 72585/ISO 15170 61076-2-101-A 60947-5-2
IP67, IP6K9K IP65, IPx4K IP67, IP6K9K IP67 IP67

H ≈ 63 mm H ≈ 54 mm H ≈ 49 mm H ≈ 51 mm H ≈ 51 mm
0.18 mm 0.25 mm 0.35 mm
NO / NC NO NC
(black) (light grey) (dark grey)

2
A B 1 2 1 2 3 1 1 1
4

Coding:
A1-2.1 1: brown 3: blue 1: brown 2: black 4: white

31

0.35 mm 0.25 mm
0.35 mm 0.25 mm0.18
0.35 mmmm 0.18 mm
0.25 mm 0.18 mm