09c Annex Pump Design

This document provides design specifications for a pump for the Faidhoka Deepboring Lift Water Supply Project in Bhaktapur, Nepal. It specifies a discharge rate of 7 liters per second to pump water 250 meters from the source to a ground tank, with a total head difference of 40 meters. Pipe sizing calculations determine a 100mm diameter pipe is suitable. Total dynamic head is calculated as 317.65 meters. A 39 horsepower pump with a discharge of 7 liters per second at 317.65 meters of head is recommended. Electricity consumption estimates show the pump would use 29.08 kW of power and operate 12 hours per day, consuming 349 kWh per day.

Uploaded by

Abinash
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
89 views5 pages

09c Annex Pump Design

This document provides design specifications for a pump for the Faidhoka Deepboring Lift Water Supply Project in Bhaktapur, Nepal. It specifies a discharge rate of 7 liters per second to pump water 250 meters from the source to a ground tank, with a total head difference of 40 meters. Pipe sizing calculations determine a 100mm diameter pipe is suitable. Total dynamic head is calculated as 317.65 meters. A 39 horsepower pump with a discharge of 7 liters per second at 317.65 meters of head is recommended. Electricity consumption estimates show the pump would use 29.08 kW of power and operate 12 hours per day, consuming 349 kWh per day.

Uploaded by

Abinash
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 5

Government of Bagmati Province

Ministry of Water Supply, Energy and Irrigation


Water Supply and Sanitation Division No. 5
Bhaktapur

Project Name: Faidhoka Deepboring Lift Water Supply Project


Design of Pump

Boring Site 1 (Around WTP Area)


Distance of pumping main, L = 250.00 m
Total Ground level difference between Source proposed and Ground Tank = 40.00 m

The discharge to be pumped, Q = 302400 L/d


Discharge to be pumped per hour pumping 12 hours = 25200 L/h
= 7.000 lps
However adapt = 7.000 lps
By Lea's formula, economic size of pumping main, D is given then:
D = 1.22√Q
Hence, D = 102.07 mm
However available size of GI pipe nearest to this size is: = 100.00 mm
Hence, use 100 mmØGI Medium Class
Calculation of head loss :
Here, discharge, Q 7.00 Lps
For 100 mmØ GI pipe
Inner Diameter of Pipe , D = 100.00 mm
For length, L = 540.00 m
Pipe material being used GI
Velocity of flow, V = Q/A = 4Q/πD² = 0.89 m/s
Absolute roughness = 1.00 mm
Coefficient of friction, f = 0.0350
Using Darcy-Weisbach equation
Headloss, H1 = f.L/D.v²/2g = 7.65 m
Assume Headloss in Pressure Filter = 15.00
Total headloss = 22.65
Total head for pumping = Level difference + headloss + Suction head
Depth of Water Table = 250.00 m
However take the dynamic level of water below the sumpwell for submersible pump as
(Assumed) = 5.00 m
Total dynamic head, H = 317.65 m
Pump model :
Phase of power supply : 3 phase
Power of pump required: 29.08 kW (39 HP) (39 HP)
Discharge : 7 lps at 317.65 m head
Use Pump of 39 HP capacity
Government of Bagmati Province
Ministry of Water Supply, Energy and Irrigation
Water Supply and Sanitation Division No. 5
Bhaktapur

Project Name: Faidhoka Deepboring Lift Water Supply Project


Data for Pump Design
Adopted Avilable
Level Design Pumping Pumping Design Length of Size of GI Total
Pumping Avilable
S/N From To Distance(m) Difference Discharge Discharge Discharge Diameter GI Pipe Pipe for Dynamic Pump model
Hour Size of GI
(m) Lps Lit./hrs. M3/hrs. of Pipe for Bore Bore Hole Head
Hole
BPD 242/8A + UMAI 150-
1 Filter Near Intake RVT (Existing1) 500 290 7.00 12 25200.00 25.2 102.07 100.00 100.00 317.65 8/22 (25 HP)
Government of Bagmati Province
Ministry of Water Supply, Energy and Irrigation
Water Supply and Sanitation Division No. 5
Bhaktapur

Project Name: Faidhoka Deepboring Lift Water Supply Project


Summary of Pumps Used and Consumption of Electricity pumps
consumption Energy consumption
(kW) m³/hr Hours of (kWh)/day
Water Water Hours of
Total no pumping
No of pump No of demand demand pumping
Name of Design discharge of at
S.N. Model of pump running at a stanby at base at design at base
Lift/Station and head pumps one One Design
time pump year year year
required pump Total pump year
Total L/day L/day hr/day
kW kW m³/hr hr/day Base year Design year
7 lps at 317.65 m
1 Filter Near Intake 1 1 2 29.08 kW 29.08 25.2 25.2 1046891 ### 12 16 349.0 465.34
head
TOTAL 29.1 25.2 349.0 465.3
For 1 year 10615.67 9198 127388.7 169849.1

Capacity of Transformer Required:

Required
Capacity of Theoritical capacity
pump running at capacity of of
S.N. Station
a time transformer transfor
(kW) (kVA) mer
(KVA)

1 1st Stage 29.08 29 29


Government of Nepal
Ministry of Water Supply
Department of Water Supply and Sanitation Division
Division No. 5, Bhaktapur

Project Name: Tallo Pasekot Water Supply Project, Budhanilkantha-6


Design of Pump (Outside Office)

Boring Site 3
Distance of pumping main, L (including pipelength for filter) = 500.00 m
Total Ground level difference between Source proposed and Ground Tank = 24.00 m

The discharge to be pumped, Q = 1209600 L/d


Discharge to be pumped per hour pumping 18 hours = 67200 L/h
= 18.667 lps
However adapt discharge = 20.000 lps
By Lea's formula, economic size of pumping main, D is given then:
D = 1.22√Q
Hence, D = 166.68 mm
However available size of GI pipe nearest to this size is: = 150.00 mm
Hence, use 150 mmØ GI pipe having bore = 150.00 mm
Calculation of head loss :
Here, discharge, Q 20.00 Lps
For 150 mmØ GI pipe
Pipe bore, D = 150.00 mm
For length, L = 554.00 m
Pipe material being used GI
Velocity of flow, V = Q/A = 4Q/πD² = 1.13 m/s
Absolute roughness = 1.00 mm
Coefficient of friction, f = 0.0339
Using Darcy-Weisbach equation
Headloss, H1 = f.L/D.v²/2g = 8.17 m
Assume Headloss in Pressure Filter (Including Softener Filter) = 15.00
Total headloss = 23.17
Total head for pumping = Level difference + headloss + Suction head
Depth of Water Table = 30.00 m
However take the dynamic level of water below the sumpwell for submersible pump as
(Assumed) = 5.00 m
Total dynamic head, H = 82.17 m
Pump model :
Phase of power supply : 3 phase
Power of pump required: 20.06 kW (27 HP)
Discharge : 67 m³/hour at 82.17 m head
Use Pump of 25 HP capacity
Government of Nepal
Ministry of Water Supply
Department of Water Supply and Sanitation Division
Division No. 5, Bhaktapur

Project Name: Tallo Pasekot Water Supply Project, Budhanilkantha-6


Design of Pump (Surface Pumping to OHT)

Boring Site 3
Distance of pumping main, L = 350.00 m
Total Ground level difference between Source proposed and Overhead Tank = 75.00 m

The discharge to be pumped, Q = 518400 L/d


Discharge to be pumped per hour pumping 20 hours = 25920 L/h
= 7.200 lps
By Lea's formula, economic size of pumping main, D is given then:
D = 1.22√Q
Hence, D = 103.52 mm
However available size of GI pipe nearest to this size is: = 100.00 mm
Hence, use 100 mmØ GI pipe having bore = 100.00 mm
Calculation of head loss :
Here, discharge, Q 7.20 Lps
For 100 mmØ GI pipe
Pipe bore, D = 100.00 mm
For length, L = 425.00 m
Pipe material being used GI
Velocity of flow, V = Q/A = 4Q/πD² = 0.92 m/s
Absolute roughness = 1.00 mm
Coefficient of friction, f = 0.0389
Using Darcy-Weisbach equation
Headloss, H1 = f.L/D.v²/2g = 7.08 m

Total headloss = 7.08


Total head for pumping = Level difference + headloss + Suction head
Depth of Water Table for ground tank = 10.00 m
However take the dynamic level of water below the sumpwell for submersible pump as
(Assumed) m
Total dynamic head, H = 92.08 m
Pump model :
Phase of power supply : 3 phase
Power of pump required: 8.67 kW (12 HP)
Discharge : 26 m³/hour at 92.08 m head
Use Pump of 15 HP capacity