0% found this document useful (0 votes)
77 views46 pages

LMF - EN Version 21.4

The document discusses Winters Instruments' electromagnetic flowmeter (LMF series). It describes the company's global presence and support network. It then provides details on the LMF series, including its modular design, maintenance-free operation, and applications in industries like water treatment, utilities, and oil/gas. Technical specifications are also listed.

Uploaded by

fatbanumarfadi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
77 views46 pages

LMF - EN Version 21.4

The document discusses Winters Instruments' electromagnetic flowmeter (LMF series). It describes the company's global presence and support network. It then provides details on the LMF series, including its modular design, maintenance-free operation, and applications in industries like water treatment, utilities, and oil/gas. Technical specifications are also listed.

Uploaded by

fatbanumarfadi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 46

ELECTROMAGNETIC FLOWMETER

www.winters.com WINTERS INSTRUMENTS


www.wintersasia.com MANUFACTURER OF INDUSTRIAL INSTRUMENTATION
Why Winters?

We're There.

Global. Operating from 10 worldwide offices in Toronto,


Calgary, Buffalo, Houston, Dubai, Shanghai, Montevideo and
Buenos Aires, Winters works closely with a vast network of
distribution partners in over 90 countries to ensure that
customers receive the instrumentation they require. This
also allows Winters to provide local support to ensure our
customers are individually serviced in the markets they
operate in.

Cover All Markets. We work with customers in industries


such as fluid power, wastewater, pharmaceutical,
petrochemical, oil and gas, process control, HVAC, power
generation, plumbing, food and beverage, agriculture, pulp
and paper, and many others. In addition, many of Winters'
products are manufactured, tested and certified in
accordance to globally recognized third party agency
requirements (3A, CSA, CRN, CE, Ex, FM, UL, NACE,
RoHS).

High Field Support. Winters maintains field located regional


sales managers who provide on-site visits and product
support to distributors, end users and OEMs. Our customer
service team is well trained in order management and can
also provide telephone support on technical challenges. In
addition to our world class customer service, Winters
conducts training programs every quarter to provide our
distribution partners with comprehensive sales tools and
keep them up-to-date on new developments in
instrumentation.
LMF Electromagnetic Flowmeter

LMF11 LMF11B LMF12


General Applications Battery Operated Heat Meter (BTU)

LMF14B
LMF13 LMF14
Insertion Type
Sanitary Type Insertion Type
Battery Operated

Products Performance & Features Product Description

 Modular functional design, practically for a variety of LMF series of electromagnetic flowmeter SMD devices and
applications. surface mount (SMT) technology, circuit reliability, low power
 No moving parts in the tube, No wear and tear. consumption, and the use of 32-bit embedded microprocessor,
 Easy to choose, easy to install, Maintenance-free and fast computing, high precision, low frequency rectangular wave
very low operating costs. excitation, The stability of the measurement. All digital
 High corrosive resistance; solid and reliable. processing, anti-interference ability, reliable measurement, high
 Up to 400: 1 turndown ratio precision.
 Easily achieve the positive cumulative flow, Reverse
Cumulative and Difference Calculation. Ultra-low power EMI switching power supply, the use of a wide
 Built-in reference electrode, fully guarantee the range of power supply voltage changes, EMC performance.
stability of measurement. Built-in three integrators, respectively, for positive cumulative,
 A variety of IP protection and installation methods, inverse cumulative and the difference calculation. With the
can be install for continuous immersion in water. average flow of automatic computing function, easy to calibrate
 Adopt EEPROM memory to measure operation data, the instrument.
safe and reliable protection of memory.
At the same time also has a small signal cut off the function, the
user can set the lower limit of the display panel and the lower
Applications limit of the flow, thus removing the interference of small signal
flow. In order to enhance the safety, the flow meter is also
 Environmental protection and water treatment. equipped with a password latch function. After power meter, if
 Municipal water supply. you need to set parameters, you must enter the advanced
 Water distribution network monitoring, Utilities, password to set the parameters to prevent unauthorized
Waterworks. personnel to change the instrument parameters.
 Water supply, District heating/cooling water.
 Waste water & Sewage water applications. Even if incident suddenly power failure, the flow meter operation
 HVAC Industry results and user settings will not disappear, EEPROM can
 Food & Beverage and Pharmaceutical. protect the set parameters and cumulative value.
 Oil & Gas/ Petrochemical
 Fine Chemical
1
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF Electromagnetic Flowmeter

Classification of Products

LMF series smart electromagnetic flow meters consist of


sensor and smart signal transducer. And it can be classified
into two structures--- integral type and remote type according to
the set-up form of the sensor and transducer. In terms of
integral type electromagnetic flow meters, transducer and
sensor directly assembles as a full ball type and can not be
dissociated.
External power supply and Battery operated type is available
as following model.

Working principle

The metering system of the electromagnetic flow meter primary


is based on Faraday’s laws of electromagnetic induction, on the
channel border which is vertical each other with metering tube
axis and line of magnetic field mount one pair detecting
electrode, when the conductive liquid move along the metering
tube axis the conductive liquid cutting the line of magnetic field
induce the inductive E.M.F. This EMF detect out by two
electrodes on the metering tube, numerical value size is:

E = KBVD
Here: E - inductive EMF;
K - instrument constant;
B - magnetic induction
V - average flow velocity in metering tube section;
D - metering tube inner diameter;

When measuring flow rate, the fluid flow through magnetic field
vertical to flow direction, the conductive liquid movement induce
one EMF in direct proportion to average flow velocity, so that
require measured flow liquid conductivity higher than lowest
limit. It’s induction voltage signal is detected by two electrodes,
and pass through a cable transmit to converter, after through
signal treatment and correlative operation, take the integrating
flow and the instantaneous delivery indicate on the display
screen of the converter.
The sensed signal voltage is converted into the indexing,
analogue, and digital output signals in the converter.

Technical Parameters

1. Normal working conditions


Ambient temperature : -25 - 60 ° C
Relative humidity : 5% to 90%
Power supply : Single-phase AC power supply (85 ~ 250) V/ (45 ~ 63) Hz
DC power supply 16VDC ~ 36VDC
Power consumption : less than 20W

2
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF Electromagnetic Flowmeter

2. Measurement accuracy

LMF11/LMF11B: 土0.2%,0.5%; LMF12: 土0.5%; LMF13: 土0.5%; LMF14/LMF14B: 土1.5%

3. Output variables

3.1 Analog current output


• Load resistance : (0-10) mA, (0 -1.5) k Ω,
(4-20) mA, (0-750)Ω。
• Basic error : 0.1% ± 10μ A,

3.2 Digital frequency output


• Frequency output range : (1 ~ 5000) Hz
• Output Electrical Isolation : Opto-isolated, isolated voltage> 1000V
• Frequency output drive : FET output, the maximum withstand voltage 36VDC, the maximum load current
of 250mA

3.3 Digital pulse output


• Output pulse range: (0-100) pulse / sec <higher than the upper elbow, will lose pulse>
• Output pulse equivalent: (0.001-1.000) m³ / cp,
(0.001-1.000) LTR /cp,
(0.001-1.000) USG /cp,
(0.001-1.000) UKG /cp ;
Output pulse width : User software settings;
Output Electrical Isolation : Opto-isolated, isolated voltage> 1000V
Pulse output drive : FET output, the maximum withstand voltage
36VDC, the maximum load current of 250mA

3.4 Alarm output


• Alarm output contact : ALMH - upper limit alarm: ALML - lower limit alarm
• Output Electrical Isolation : Opto-isolated, isolated voltage> 1000V
• Alarm output drive : transistor output, the maximum withstand voltage of 36V, the maximum load
current of 250mA

3.5 Digital communication interface and communication protocol:


• MODBUS interface
• RTU format
• Physical interface RS-485
• Electrical isolation 1000V
• HART interface: support standard HART protocol, configure the HART Communicator, can display the
measured value online, and modify the instrument parameters

3
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF Electromagnetic Flowmeter

SPECIFICATIONS
LMF11 LMF11B LMF12 LMF13 LMF14 LMF14B
Insertion
General Type
Type General Type Heat Meter (BTU) Sanitary Type Insertion Type Battery
(Battery Operated)
Operated

Accuracy ±0.2% , ±0.5% ±0.5% ±1.0% ; ±1.5%

Repeatability ±0.06% , ±0.16% ±0.16% ±0.05%

Medium
-25 ~ 200℃ -25 ~ 130℃
temperature

Conductivity ≥ 5 μS / cm (softening water) ≥ 20 μS / cm)

Calibration range 3-2000mm 25-1200mm 3-2000mm 10-125mm 100-2000mm

0.6MPa / 1.0MPa / 1.6MPa /


0.6MPa / 1.0MPa / 1.6MPa / 2.5MPa / 4.0MPa / on request 1.0MPa
on request
Operating
Pressure
Class 150 /
N/A
Class 300

Flowrate 0.5 ~ 1.0 m/s

Flow direction Forward / Reverse

Hard rubber N/A


Lining
PTFE N/A PTFE
material
F46/ PFA N/A

SS316L
Electrode
material
Hastelloy B/ Hastelloy C/ Titanium/ Tantalum/ Platinum Iridium/ Tungsten carbide N/A

Number of
4 3 4 2
electrodes

Carbon steel N/A


Flange
material
SS304/ SS316/ SS316L

Installation Tri-clamp / Insertion flange/ Thread Type /


Flange Type / Wafer type (without flange)
method thread Online plug-in

IP 65
IP 65 IP 65
IP 67
Protection IP 67 IP 67
IP 68 IP 65 IP 68 IP 68
class IP 68 IP 68
(Remote type
(Remote type only) (Remote type only)
only)

Build-in lithium Build-in lithium


Power supply 230 VAC / 24 VDC battery/ 230 VAC / 24 VDC battery/
12V ~ 24V DC 12V ~ 24V DC

Output 4-20mA + pulse N/A 4-20mA 4-20mA + pulse N/A

HART / HART /
RS485 / GPRS / RS485 / GPRS
Communication Modbus / Modbus Modbus / HART / Modbus
CMDA / CMDA
Profibus Profibus

Sensor type Integrated / Remote Remote Integrated / Remote

Ambient Ambient Temperature -25 ~ 60°C, Humidity 5% to 90%

4
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF Electromagnetic Flowmeter

Flowmeter nominal size, pressure and flow range

The instantaneous volume flow is a function of the flow rate and the sensor aperture. The instantaneous flow bar graph
shows the flow range that each flow meter can measure, and gives several sensor specifications suitable for measuring
a given flow rate.

Size Pressure Min. flowrate Max. flowrate


DN MPa 0.5m/s 1.0m/s
3 4.0 0.2 l/min 4 l/min
4 4.0 0.4 l/min 8 l/min
6 4.0 1.0 l/min 20 l/min
8 4.0 1.5 l/min 30 l/min
10 4.0 2.25 l/min 45 l/min
15 4.0 5.0 l/min 100 l/min
20 4.0 7.5 l/min 150 l/min
25 4.0 10 l/min 200 l/min
32 4.0 20 l/min 400 l/min
40 4.0 30 l/min 600 l/min
50 4.0 3 m³/h 60 m³/h
65 4.0 6 m³/h 120 m³/h
80 4.0 9 m³/h 180 m³/h
100 1.6 12 m³/h 240 m³/h
125 1.6 21 m³/h 420 m³/h
150 1.6 30 m³/h 600 m³/h
200 1.6 54 m³/h 1080 m³/h
250 1.6 90 m³/h 1800 m³/h
300 1.6 120 m³/h 2400 m³/h
350 1.6 165 m³/h 3300 m³/h
400 1.6 225 m³/h 4500 m³/h
450 1.0 286 m³/h 5700 m³/h
500 1.0 330 m³/h 6600 m³/h
600 1.0 480 m³/h 9600 m³/h
700 1.0 660 m³/h 13200 m³/h
800 1.0 900 m³/h 18000 m³/h
900 1.0 1200 m³/h 24000 m³/h
1000 1.0 1350 m³/h 27000 m³/h
1200 0.6 2100 m³/h 42000 m³/h
1400 0.6 2700 m³/h 54000 m³/h
1600 0.6 3600 m³/h 72000 m³/h
1800 0.6 4500 m³/h 90000 m³/h
2000 0.6 5700 m³/h 114000 m³/h

5
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF Electromagnetic Flowmeter

The instantaneous flow of the electromagnetic flowmeter

example:
Instantaneous flow rate + 7m3 / h (maximum
value is the upper limit of the range). When the
flow rate is between 0.5 and 10 m / s, the
applicable sensor diameter [DN20-DN65].

DN3 - DN100 DN125- DN2000

6
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF Electromagnetic Flowmeter

Selection of Electrode Material(s)

The material of the electrode is selected according to the corrosiveness of the fluid to be measured.

Material Corrosion resistance

1. Domestic water, industrial water, raw water, urban water


SS 316L 2. Dilute acid, dilute alkali and other weak corrosive, alkaline salt solution

1. Hydrochloric acid <less than 10% concentration) and other non - oxidizing acid
2. Uranium hydroxide (concentration less than 50%) of all concentrations of ammonium
Hastelloy B hydroxide alkaline solution.
3. Phosphoric acid, organic acids
*Not applicable: nitric acid

1. A mixed solution of a mixed acid such as chromic acid and sulfuric acid
Hastelloy C 2. Oxidizing salts such as Fe +++, Cu ++, seawater
*Not applicable: hydrochloric acid

1. Salt, such as
a) chloride (oxide / magnesium / aluminum / calcium / plating / iron, etc.)
b) Sodium salt, ammonium salt, hypochlorite, sea water
Titanium 2. Concentration of less than 50% potassium hydroxide, ammonium hydroxide, barium
hydroxide alkaline solution
*Not applicable: hydrochloric acid, sulfuric acid, phosphoric acid, hydrofluoric acid and
other reducing acids

1. Hydrochloric acid (concentration less than 40%), dilute sulfuric acid and concentrated
sulfuric acid (not including fuming sulfuric acid)
2. Chlorine dioxide, ferric chloride, hypochlorous acid, sodium cyanide, lead acetate,
Tantalum etc.
3. Nitric acid (including fuming nitric acid) and other oxidizing acid, the temperature
below 80 ℃ of aqua regia
*Not applicable: Alkaline, hydrofluoric acid

1. Applicable: almost all acid, alkali, salt solution <including fuming sulfuric acid, fuming
Platinum (Pt) nitric acid)
*Not applicable: aqua regia, ammonium salt

Tungsten 1. Applicable: pulp, sewage, can interfere with solid particles


carbide *Not applicable: inorganic acid, organic acid, chloride

7
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF Electromagnetic Flowmeter

Selection of Lining Material(s)

Should be based on the corrosion of the measured medium, wear and temperature to choose. Hard / soft rubber can
be resistant to the general weak acid, alkali corrosion, temperature 65 ℃, soft rubber wear resistance, PTFE (PTFE)
almost resistant to heat acid other than strong acid, alkali corrosion, medium temperature up to 130 ℃, but not wear
and tear. Polyurethane rubber has good wear resistance, but not acid, alkali corrosion, temperature resistance is also
poor, the medium temperature is less than 65 ℃.

Lining material The main function Applicable scope

Hard rubber • Can be resistant to hydrochloric • Below 65ºC


acid at room temperature, acetic • General acid, alkali, salt solution
acid, oxalic acid, ammonia,
phosphoric acid and 50% sulfuric
acid, sodium hydroxide, potassium
hydroxide
• Avoid strong oxidants
Soft rubber • Have better flexibility, better wear • Below 65 ° C
resistance • Measure the general water,
• Resistance to the general low sewage, mud, pulp
concentration of acid, alkali, salt • Weak acid, weak base, salt
medium corrosion medium

Polypropylene • Have good insulation, physical and • Below 90 ° C


(PP) chemical properties, viscosity • Common water, hot water, sewage
• Weak vinegar, weak base, salt, and industrial wastewater
oxidizer

Polytetrafluoroethylene • The most stable chemical properties • -40ºC to 130ºC (PTFE)


(PTFE) of plastic in a material, the ability to • -40ºC to 180ºC (F46)
boil hydrochloric acid, sulfuric acid, • -40ºC to 200ºC (PFA)
High temperature insulation nitric acid and aqua regia, but also • Acid, alkali and other strong
(F46) resistant to alkali and a variety of corrosive media
organic solvents • Sanitary media
Solubility poly • Poor wear resistance and poor
tetrafluoroethylene adhesion
(PFA)

Protection Level

According to EN60529 standard, the enclosure protection class can be divided into:

• IP65 for the spray type, you can allow the faucet from any direction of the instrument water, spray pressure of
30kPa, the water is 12.5 liters / min, spray from the instrument from the distance of 3 meters.

• IP67 for the anti-flooding type, that is, the instrument can be immersed in water for a short time, the highest
point should be underwater at least 150cm, duration of at least 30 minutes.

• IP68 for the diving type, should be able to work long hours in the water, the maximum depth of its penetration
by the manufacturer and the user consultation.

Protection principle selection principle should be based on the above requirements and the actual conditions of
the instrument selected. If the instrument below the ground, often flooded, should use IP68: If the instrument on
the ground, you can use IP65.

8
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF
Electromagnetic Flowmeter
(General Application, Battery-operated)

LMF11 LMF11B LMF12


(General Application) (Battery-operated) Heat Meter (BTU)

Specification
Model LMF11 LMF11B LMF12

General Type
Type General Applications Heat Meter (BTU)
(Battery Operated)

Accuracy ±0.2%, ±0.5% ±0.5%

Repeatability ±0.06% , ±0.16% ±0.5%

Medium temperature -25 ~ 200℃

Conductivity ≥ 5 μS / cm (softening water ≥ 20 μS / cm)

Nominal size DN6 – DN2000 DN10 – DN1200 DN6 – DN2000

Operating Pressure 0.6MPa / 1.0MPa / 1.6MPa / 2.5MPa / 4.0MPa / on request

Flowrate 0.5 ~ 1.0 m/s

Flow direction Forward / Reverse

Electrode material SS316L/ Hastelloy B/ Hastelloy C/ Titanium/ Tantalum/ Platinum Iridium/ Tungsten carbide

Lining material Hard rubber/ PTFE/ F46/ PFA

Number of electrodes 4 3 4

Measuring tube
SS304
material

Flange material Carbon steel/ SS304/ SS316/ SS316L

Installation method Flange Type / Wafer type (without flange)

Build-in Lithium battery (≥ 6 yrs)


Power supply 230 VAC/ 24VDC External lithium battery pack (≥10 yrs) 230 VAC/ 24VDC
12-24 VDC external power

Low power consumption, standard conventional lithium battery pack (3.6V) for 5 to 6 years of continuous work and
Battery Life (LMF11B) optional external battery pack to achieve the maximum battery life more than 10 years, reducing flow meter after
installation maintenance costs.

IP65 IP65
Protection class IP67 IP68 IP67
IP68 (remote type only) IP68 (remote type only)

Output 4-20mA /Pulse/ Frequency N/A 4-20mA /Pulse/ Frequency

Electrical connection M20 x 1.5; 1 /2” – 14NPT M16 x 1.5 M20 x 1.5; 1 /2” – 14NPT

Communication HART / Modbus (RS485) RS485 / GPRS / CDMA Modbus (RS485)

Sensor Type Integrated / Remote Remote

Language Selectable English/ Chinese

9
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF Electromagnetic Flowmeter

LMF11 - Dimension (mm)

90
126
115
115
102

93.5 48

Ø123

118
78.5

2-M20x1.5 Ø100

n x Ød
B

84
C

30 2-M20x1.5
ØK

A ØD

LMF 11
Nominal size
DN6 ~ 450

110 152 180

Ø100
110

323
76

Ø80

241

LMF 11
Remote type with pipe mounting

10
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF Electromagnetic Flowmeter

LMF11 - Dimension (mm)

90
126 115
102
93.5 48

40
Ø123

118
78.5
78.5

2-M20x1.5
n-
Ø100
Ø
d

84
2-M20x1.5
30

E
F ØK
A ØD LMF11
Nominal size
DN 500 ~ 2000

11
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF Electromagnetic Flowmeter

LMF11/12 - Dimension (mm)

LMF11/12 Transducer (IP65)


Sensor nominal size below DN500
refer LMF11

LMF11/12 Remote Type Sensor


Nominal size
DN500 – DN2000

12
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF Electromagnetic Flowmeter

LMF11B - Dimension (mm)

Ø95 Ø123

118
180
.5
6 x1
M1
4-

Ød Ø100
nx
B

84
C

30 2-M20x1.5

A ØDI

DN

ØK
LMF11B
ØD
Nominal size
DN10 ~ 32

Ø95 151 Ø123


180

4 -M
16 x
1.5
393
76

Ø80

211

LMF11B
Remote type with pipe mounting

13
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF Electromagnetic Flowmeter

LMF11B - Dimension (mm)

Ø95 Ø123

118
180

Ø100
4-M16 x 1.5

d
Ø
x
n
C

84
B

30 2-M20x1.5

ØDI
A DN
K
LMF11B
D
Nominal size
DN40 ~ 450

Ø95 Ø123
180

118

x1.5
4-M16
n x Ød
Ø100
84

2-M20x1.5
30

F E
A ØK
ØD LMF11B
Nominal size
DN500 ~ 1200

14
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF Electromagnetic Flowmeter

LMF11 / LMF11B / LMF12 Nominal Dimension (mm)

Pressure
DN
MPa A B C E F ΦD ΦK n x Φd
10 90 60

15 95 50 95 65
4 x Φ14
20 105 75
150
25 100 55 115 85

32 4.0 105 60 140 100

40 110 65 150 110 4 x Φ18

50 121 76 165 125

65 197/202 130 85 185 145

80 135 90 200 160


8 x Φ18
100 145 100 220 180
247/252
125 161 116 245 210

150 297/302 171 126 280 240 8 x Φ22

200 348/352 199 154 335 295 12 x Φ26


1.6
250 398/402 224 179 405 355
12 x Φ22
300 249 204 440 400
498/502
350 274 229 500 460 16 x Φ22

400 305 260 565 515 16 x Φ26


598/602
450 330 285 615 565
20 x Φ26
500 360 403 240 670 620
/600 300
600 410 453 270 780 725 20 x Φ30

700 1.0 /700 467 560 350 895 840 24 x Φ30

800 /800 517 610 400 1010 950 24 x Φ33


400
900 /900 567 660 470 1110 1050 28 x Φ33

1000 /1000 617 712 570 1225 1160 28 x Φ36

1200 /1200 719 814 710 1400 1340 32 x Φ33


600
1400 /1400 819 914 900 1625 1560 36 x Φ36

1600 0.6 /1600 919 1036 1040 1825 1760 40 x Φ36

1800 /1800 1021 1138 800 1180 2045 1970 44 x Φ39

2000 /2000 1121 1238 1350 2265 2180 48 x Φ42

15
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF11 Electromagnetic Flowmeter
(General Application)
LMF11 – Ordering information

Description Series

General application flowmeter LMF11

Accuracy level

Standard ±0.5% A

High Precision ±0.2% B

Installation method

Flange F

Lining material

Hard Rubber H

PTFE T

F46 R

PFA P

on request Z

Nominal size Pressure rating

DN6 4.0MPa (PN40) 06

DN8 4.0MPa (PN40) 08

DN10 4.0MPa (PN40) 10

DN15 4.0MPa (PN40) 15

DN20 4.0MPa (PN40) 20

DN25 4.0MPa (PN40) 25

DN32 4.0MPa (PN40) 32

DN40 4.0MPa (PN40) 40

DN50 4.0MPa (PN40) 50

DN65 4.0MPa (PN40) 65

DN80 4.0MPa (PN40) 80

DN100 1.6MPa (PN16) 1H

DN125 1.6MPa (PN16) 1Q

DN150 1.6MPa (PN16) 1F

DN200 1.6MPa (PN16) 2H

DN250 1.6MPa (PN16) 2F

DN300 1.6MPa (PN16) 3H

DN350 1.6MPa (PN16) 3F

DN400 1.6MPa (PN16) 4H

DN450 1.0MPa (PN10) 4F

DN500 1.0MPa (PN10) 5H

DN600 1.0MPa (PN10) 6H

DN700 1.0MPa (PN10) 7H

DN800 1.0MPa (PN10) 8H

DN900 1.0MPa (PN10) 9H

DN1000 1.0MPa (PN10) 1T

DN1200 0.6MPa (PN6) 2M

DN1400 0.6MPa (PN6) 4M

DN1600 0.6MPa (PN6) 6M

DN1800 0.6MPa (PN6) 8M

DN2000 0.6MPa (PN6) 0M

16
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF11 Electromagnetic Flowmeter
(General Application)
LMF11 – Ordering information continue…

Note: When the accuracy is ± 0.2%, the caliber is limited to DN10 ~ DN1000.

Electrode material Electrode grounding

SS 316L Yes E

Hastelloy B Yes N

Hastelloy C Yes O

Titanium Yes I

Tantalum Yes Q

Platinum Iridium Yes G

Tungsten carbide Yes V

on request Yes Z

Operating pressure

0.6MPa (PN6) B

1.0MPa (PN10) C

1.6MPa (PN16) D

2.5MPa (PN25) E

4.0MPa (PN40) F

Class 150 G

Class 300 H

on request Z

Flange material

Wafer type (without flange) – Only available for DN6; DN8 & DN10 0

Carbon steel 1

SS 304 2

SS 316 3

SS 316L 4

Companion flange

No 0

Carbon steel 1

SS 304 2

SS 316 3

SS 316L 4

Grounding ring

No 0

SS 304 B

SS 316 C

SS 316L D

on request Z

Process temperature

Standard <65 ℃ 0

Standard <130 °C 1

Standard <180 °C 2

Standard <200 °C 3

Display LCD & sensor

Integrated T

Remote type R

17
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF11 Electromagnetic Flowmeter
(General Application)
LMF11 – Ordering information continue…

Output + Communication

4 ~ 20mA + pulse 01

4 ~ 20mA + HART 02

4 ~ 20mA + Modbus 03

4 ~ 20mA + Profibus 04

Power supply

230 VAC G

24 VDC K

Protection class

IP65 0

IP67 1

IP68 (Remote type only) 2

Explosion protection

No 0

Flameproof Ex-d, Ex-ia IIC T3~T6 EX

Electrical connection

M20 × 1.5 0

1/2 "-14 NPT 1

Cable length (Remote type only)

Standard 5 meters R5

on request (up to 50 meters) RX

Sensor selection material (Optional)

SS 304 -X

SS 316 -Y

SS 316L -Z

on request /0

18
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF11B
Electromagnetic Flowmeter
(Battery-operated)
LMF11B – Ordering information

Description Series

Battery-operated flowmeter LMF11B

Accuracy level

Standard ±0.5% A

High Precision ±0.2% B

Installation method

Flange F

Lining material

Hard Rubber H

PTFE T

F46 R

PFA P

on request Z

Nominal size Pressure rating

DN10 4.0MPa 10

DN15 4.0MPa 15

DN20 4.0MPa 20

DN25 4.0MPa 25

DN32 4.0MPa 32

DN40 4.0MPa 40

DN50 4.0MPa 50

DN65 4.0MPa 65

DN80 4.0MPa 80

DN100 1.6MPa 1H

DN125 1.6MPa 1Q

DN150 1.6MPa 1F

DN200 1.6MPa 2H

DN250 1.6MPa 2F

DN300 1.6MPa 3H

DN350 1.6MPa 3F

DN400 1.6MPa 4H

DN450 1.0MPa 4F

DN500 1.0MPa 5H

DN600 1.0MPa 6H

DN700 1.0MPa 7H

DN800 1.0MPa 8H

DN900 1.0MPa 9H

DN1000 1.0MPa 1T

DN1200 0.6MPa 2M

Electrode material

SS 316L E

Hastelloy C O

on request Z

19
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF11B
Electromagnetic Flowmeter
(Battery-operated)
LMF11B – Ordering information continue…

Operating pressure

0.6MPa B

1.0MPa C

1.6MPa D

2.5MPa E

4.0MPa F

on request Z

Flange material

Wafer type (without flange) 0

Carbon steel 1

SS 304 2

on request 3

Companion flange

No 0

Carbon steel 1

SS 304 2

on request Z

Grounding ring

No 0

SS 304 B

on request Z

Process temperature

Standard <65 ℃ 0

Standard <130 °C 1

Standard <180 °C 2

on request Z

Display LCD & sensor

Integrated T

Remote type R

Communication Power Source

RS485 Build-in lithium battery 01

RS485 12V-24VDC external power supply 02

GPRS Built-in lithium battery 03

CDMA Built-in lithium battery 04

Power supply

Built-in lithium battery C

Built-in lithium battery-powered + 12V-24VDC external power supply E

Protection class

IP68 2

Cable length (Remote type only)

Standard 5 meters R5

on request (up to 10 meters) RX

20
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF11B
Electromagnetic Flowmeter
(Battery-operated)
LMF11B – Ordering information continue…

Pressure sensor interface (optional)

No N

Yes Y

External power supply (optional)

External lithium battery pack 01

Solar power 02

Note 1: Modified PP lining only applies to the diameter DN25-DN300.

Note 2: DN10-20 F46 lining only.

Advantages:

- No External Power Required for Remote Locations (Battery Operated Type)


- Low power consumption, standard conventional lithium battery pack (3.6V) for 5 to 6 years of continuous work (depends on the
time interval, easy to change the battery).
- Optional external battery can be achieve the maximum battery life more than 10 years, it can be reduce the flow meter
maintenance costs.

More information of battery life 5 year service life for transmitter, data collection every 20 minutes.
The data of flow, for example:
2016/09/19/12:05 100l/s
2016/09/19/12:25 102l/s
2016/09/19/12:45 101l/s

Every 20 minutes, the transmitter will record the time and flow data.
The module will package 3 data, and send the data to data collection server every 1 hour.

This standard data collection and sending frequency in enough for most of application, more frequent of data collection and sending,
more power would be consume by transmitter or module, that would make the service life decrease.

5 year service life for CDMA/GPRS module, data sending every 1 hour.

21
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF12 Electromagnetic Flowmeter
(Heat Meter - BTU)
LMF12 – Ordering information

Description Series

Heat Meter (BTU )flowmeter LMF12

Accuracy level

Standard ±0.5% A

Installation method

Flange F

Temperature sensor

PT1000 T1

Lining material

Hard Rubber H

PTFE T

F46 R

PFA P

on request Z

Nominal size Pressure rating

DN6 4.0MPa 06

DN8 4.0MPa 08

DN10 4.0MPa 10

DN15 4.0MPa 15

DN20 4.0MPa 20

DN25 4.0MPa 25

DN32 4.0MPa 32

DN40 4.0MPa 40

DN50 4.0MPa 50

DN65 4.0MPa 65

DN80 4.0MPa 80

DN100 1.6MPa 1H

DN125 1.6MPa 1Q

DN150 1.6MPa 1F

DN200 1.6MPa 2H

DN250 1.6MPa 2F

DN300 1.6MPa 3H

DN350 1.6MPa 3F

DN400 1.6MPa 4H

DN450 1.0MPa 4F

DN500 1.0MPa 5H

DN600 1.0MPa 6H

DN700 1.0MPa 7H

DN800 1.0MPa 8H

DN900 1.0MPa 9H

DN1000 1.0MPa 1T

DN1200 0.6MPa 2M

22
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF12 Electromagnetic Flowmeter
(BTU Meter)
LMF12 – Ordering information continue…

Nominal size Pressure rating

DN1400 0.6MPa 4M

DN1600 0.6MPa 6M

DN1800 0.6MPa 8M

DN2000 0.6MPa 0M

Note: Standard without temperature sensor

Electrode material Electrode grounding

SS 316L Yes E

Hastelloy B Yes N

Hastelloy C Yes O

on request Yes Z

Operating pressure

0.6MPa B

1.0MPa C

1.6MPa D

2.5MPa E

4.0MPa F

on request Z

Flange material

Wafer type (without flange) 0

Carbon steel 1

SS 304 2

SS 316 3

SS 316L 4

Companion flange

No 0

Carbon steel 1

SS 304 2

SS 316 3

SS 316L 4

Grounding ring

No 0

SS 304 B

SS 316 C

SS 316L D

Process temperature

Standard <65 ℃ 0

Standard <90 °C 1

Standard <130 °C 2

Standard <180 °C 3

Standard <200 °C 4

Display LCD & sensor

Remote type R

Output + Communication

4 ~ 20mA + Modbus 01

23
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF12 Electromagnetic Flowmeter
(Heat Meter - BTU)
LMF12 – Ordering information continue…

Power supply

230 VAC G

24 VDC K

Protection class

IP65 0

IP67 1

IP68 2

Explosion protection

No 0

Flameproof Ex-d, Ex-ia IIC T3~T6 EX

Electrical connection

M20 × 1.5 0

1/2 "-14 NPT 1

Cable length (Remote type only)

Standard 5 meters R5

On request (up to 50 meters) RX

Sensor selection material (Optional)

SS 304 -X

SS 316 -Y

SS 316L -Z

24
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF13 Electromagnetic Flowmeter
(Sanitary Type)

LMF13 - Dimension (mm)

Pressure
DN
MPa L D H
10
15 100 287
20
180
25
32 110 297
40 1.0
50 152 339
65 230 170 357
80 180 367
100 200 387
270
125 246 426

25
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF13 Electromagnetic Flowmeter
(Sanitary Type)
LMF13 – Ordering information

LMF13 Series Flowmeter DN10-DN125

Accuracy standard: ± 0.5%

Description Series

Sanitary flowmeter LMF13

Pipe connection

Tri-Clamp (3A) T

DIN11851 R

on request Z

Lining material

F46 R

PFA P

Pipe connection size

DN10 10

DN15 15

DN20 20

DN25 25

DN32 32

DN40 40

DN50 50

DN65 65

DN80 80

DN100 1H

DN125 1Q

Electrode material Electrode grounding

SS 316L No S

Hastelloy B No B

Hastelloy C No H

Titanium No M

Tantalum No T

Platinum Iridium No P

Tri-clamp material

SS 304 0

SS 316 1

SS 316L 2

Tri-clamp pressure rating

1.0 MPa C

Process temperature

Standard <180 °C 1

Standard <200 °C 2

Display LCD & sensor

Integrated T

Remote type R

Power supply

230 VAC G

24 VDC K

26
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF13 Electromagnetic Flowmeter
(Sanitary Type)
LMF13 – Ordering information continue…

Output + Communication

4 ~ 20mA + pulse 01

4 ~ 20mA + HART 02

4 ~ 20mA + Modbus 03

4 ~ 20mA + Profibus 04

Protection class

IP65 (Standard) 0

Explosion protection

No 0

Flameproof Ex-d, Ex-ia IIC T3~T6 EX

Electrical connection

M20 × 1.5 0

1/2 "-14 NPT 1

Cable length (Remote type only)

Standard 5 meters R5

on request (up to 50 meters) RX

Sensor selection material (Optional)

SS 304 -X

SS 316 -Y

SS 316L -Z

27
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
Electromagnetic Flowmeter
LMF14
(Insertion Type)

Products Performance & Features

• LMF14 Insertion Type Electromagnetic Flowmeter with


simple installation, Plug-in/out type support insert into
the pipe and easily disassembly, re-installed without
stop water supply, convenient for regular calibration
and inspection.

• A variety of power supply options: 230VAC/ 24VDC/


Battery Operated

• Adopt EEPROM memory to measure operation data,


safe and reliable protection of memory.

LMF14 LMF14B
(Battery Operated)

Product Description

LMF series of electromagnetic flowmeter SMD devices and surface mount (SMT) technology, circuit
reliability, low power consumption, and the use of 32-bit embedded microprocessor, fast computing, high
precision, low frequency rectangular wave excitation, The stability of the measurement. All digital
processing, anti-interference ability, reliable measurement, high precision.

Ultra-low power EMI switching power supply, the use of a wide range of power supply voltage changes,
EMC performance. Built-in three integrators, respectively, for positive cumulative, inverse cumulative and
the difference calculation. With the average flow of automatic computing function, easy to calibrate the
instrument.

At the same time also has a small signal cut off the function, the user can set the lower limit of the display
panel and the lower limit of the flow, thus removing the interference of small signal flow. In order to
enhance the safety, the flow meter is also equipped with a password latch function. After power meter, if
you need to set parameters, you must enter the advanced password to set the parameters to prevent
unauthorized personnel to change the instrument parameters.

Even if the scene suddenly power, the flow meter operation results and user settings will not disappear,
EEPROM can protect the set parameters and cumulative value.

28
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
Electromagnetic Flowmeter
LMF14
(Insertion Type)

Working principle

The metering system of the electromagnetic flow meter primary is based on Faraday’s laws of
electromagnetic induction, on the
channel border which is vertical each other with metering tube axis and line of magnetic field mount one
pair detecting electrode,
when the conductive liquid move along the metering tube axis the conductive liquid cutting the line of
magnetic field induce the
inductive E.M.F. This EMF detect out by two electrodes on the metering tube, numerical value size is:

E=KBVD

E - inductive EMF;
K - instrument constant;
B - magnetic induction
V - average flow velocity in metering tube section;
D - metering tube inner diameter;

When measuring flow rate, the fluid flow through magnetic field vertical to flow direction, the conductive
liquid movement induce one EMF in direct proportion to average flow velocity, so that require measured
flow liquid conductivity higher than lowest limit. It’s induction voltage signal is detected by two electrodes,
and pass through a cable transmit to converter, after through signal treatment and correlative operation,
take the integrating flow and the instantaneous delivery indicate on the display screen of the converter.

The sensed signal voltage is converted into the indexing, analogue, and digital output signals in the
converter.

Technical Parameters

1. Normal working conditions


Ambient temperature : -25 - 60° C
Relative humidity : 5% to 90%
Power supply : Single-phase AC power supply 85 ~ 250 VAC/ 45 ~ 63 Hz
DC power supply 16VDC ~ 36VDC
Power consumption : Less than 20W

29
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
Electromagnetic Flowmeter
LMF14
(Insertion Type)

2. Measurement accuracy

LMF14/LMF14B: 土1.5%; 1.0%

3. Output variables

3.1 Analog current output


• Load resistance: (0-10) mA, (0 -1.5) k Ω,
(4-20) mA, (0-750)Ω。
• Basic error: 0.1% ± 10μ A,

3.2 Digital frequency output


• Frequency output range: (1 ~ 5000) Hz
• Output Electrical Isolation: Opto-isolated, isolated voltage> 1000V
• Frequency output drive: FET output, the maximum withstand voltage 36VDC, the maximum load
current of 250mA

3.3 Digital pulse output


• Output pulse range: (0-100) pulse / sec <higher than the upper elbow, will lose pulse>
• Output pulse equivalent: (0.001-1.000) m³ / cp,
(0.001-1.000) LTR /cp,
(0.001-1.000) USG /cp,
(0.001-1.000) UKG /cp ;
Output pulse width: User software settings;
Output Electrical Isolation: Opto-isolated, isolated voltage> 1000V Pulse
output drive: FET output, the maximum withstand voltage 36VDC, the
maximum load current of 250mA

3.4 Alarm output


• Alarm output contact: ALMH - upper limit alarm: ALML - lower limit alarm
• Output Electrical Isolation: Opto-isolated, isolated voltage> 1000V
• Alarm output drive: transistor output, the maximum withstand voltage of 36V, the maximum load
current of 250mA

3.5 Digital communication interface and communication protocol:


• MODBUS interface,
• RTU format,
• Physical interface RS-485,
• Electrical isolation 1000V
• HART interface: support standard HART protocol, configure the HART Communicator, can display
the measured value online, and modify the instrument parameters

30
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
Electromagnetic Flowmeter
LMF14
(Insertion Type)

Specifications
LMF14 LMF14B

Type Insertion Type Insertion Battery Operated


Accuracy ±1.0% ; ±1.5%

Repeatability ±0.05%

Medium temperature -25 ~ 130℃

Conductivity ≥ 5 μS / cm (softening water ≥ 20 μS / cm)

Nominal size 200-2000mm

0.6MPa / 1.0MPa / 1.6MPa /


Operating Pressure
on request

Flowrate 0.5 ~ 1.0 m/s

Flow direction Positive / Negative

Lining
PTFE
material

Electrode
SS316L
material

Number of electrodes 2

Installation method Insertion Fixed Flange / Plug-in/out

IP65 -
Protection
IP 67 -
class
IP 68 (Remote type only) IP68

Built-in lithium battery (3.6V)


External lithium battery
Power supply 240 VAC/ 24VDC
12V ~ 24V
(External Power)

Low power consumption, standard conventional lithium battery pack (3.6V) for 5 to 6
Battery Operated Life
years of continuous work and optional external battery pack to achieve the maximum
(LMF14B)
battery life more than 10 years, reducing flow meter after installation maintenance costs.

Output 4-20mA/ Pulse/ Frequency N/A

Communication HART / RS485 Modbus/ Profibus RS485 Modbus / GPRS / CMDA

Electrical connector M20×1.5; 1/2-14NPT M16×1.5

Sensor type Integrated /Remote Type

Ambient Ambient Temperature -25 ~ 60°C, Humidity 5% to 90%

31
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
Electromagnetic Flowmeter
LMF14
(Insertion Type)

Flowmeter nominal size, pressure and flow range

The instantaneous volume flow is a function of the flow rate and the sensor aperture. The instantaneous
flow bar graph shows the flow range that each flow meter can measure, and gives several sensor
specifications suitable for measuring a given flow rate.

Size Pressure Min. flowrate Max. flowrate


DN MPa 0.5m/s 1.0m/s
200 1.6 54 m³/h 1080 m³/h
250 1.6 90 m³/h 1800 m³/h
300 1.6 120 m³/h 2400 m³/h
350 1.6 165 m³/h 3300 m³/h
400 1.6 225 m³/h 4500 m³/h
450 1.0 286 m³/h 5700 m³/h
500 1.0 330 m³/h 6600 m³/h
600 1.0 480 m³/h 9600 m³/h
700 1.0 660 m³/h 13200 m³/h
800 1.0 900 m³/h 18000 m³/h
900 1.0 1200 m³/h 24000 m³/h
1000 1.0 1350 m³/h 27000 m³/h
1200 0.6 2100 m³/h 42000 m³/h
1400 0.6 2700 m³/h 54000 m³/h
1600 0.6 3600 m³/h 72000 m³/h
1800 0.6 4500 m³/h 90000 m³/h
2000 0.6 5700 m³/h 114000 m³/h

32
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
Electromagnetic Flowmeter
LMF14
(Insertion Type)

LMF14 - Dimension (mm) & Installation method

LMF14
Flange fixed type connection
DN200 ~ 2000

33
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
Electromagnetic Flowmeter
LMF14
(Insertion Type)

LMF14 - Dimension (mm) & Installation method

LMF14
Plug-in/out type connection
DN200 ~ 2000

34
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF14 Electromagnetic Flowmeter
(Insertion Type)
LMF14 – Ordering information

Description Series

Insertion flowmeter LMF14

Accuracy level

Standard ±1.5% A

High Precision ±1.0% B

Installation method

Fixed type without ball Valve B

Plug-in/out type with ball Valve Z

Lining material

PTFE T

on request Z

Nominal size

DN200 2H

DN250 2F

DN300 3H

DN350 3F

DN400 4H

DN450 4F

DN500 5H

DN600 6H

DN700 7H

DN800 8H

DN900 9H

DN1000 1T

DN1200 2M

DN1400 4M

DN1600 6M

DN1800 8M

DN2000 0M

Electrode material

SS 316L S

Hastelloy C H

Operating pressure

0.6MPa B

1.0MPa C

1.6MPa D

on request Z

Flange material Companion flange

SS 304 (DN100 PN1.6) No 0

SS 304 (DN100 PN1.6) Carbon steel + welding base 1

SS 304 (DN100 PN1.6) Stainless steel + welding base 2

Process temperature

Standard <130 °C 0

35
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF14 Electromagnetic Flowmeter
(Insertion Type)
LMF14 – Ordering information continue…

Display LCD & sensor

Integrated T

Remote type R

Output + communication

4 ~ 20mA + pulse 01

4 ~ 20mA + HART 02

4 ~ 20mA + Modbus 03

Power supply

240 VAC G

24 VDC K

Protection class

IP65 (standard) 0

IP67 1

IP68 (remote type only) 2

Explosion protection

No 0

Flameproof Ex-d, Ex-ia IIC T3~T6 EX

Electrical Connector

M20 x 1.5 0

1/2” – 14” NPT 1

Cable length (Remote type only)

Standard 5 meters R5

on request (up to 10 meters) RX

36
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF14B
Electromagnetic Flowmeter
(Insertion Type, Battery-operated)
LMF14B – Ordering information

Description Series

Insertion flowmeter with LMF14B


battery-operated

Accuracy level

Standard ±1.5% A

High Precision ±1.0% B

Installation method

Flange Fixed type B

Plug-in/out type with ball Valve Z

Lining material

PTFE T

on request Z

Nominal size

DN200 2H

DN250 2F

DN300 3H

DN350 3F

DN400 4H

DN450 4F

DN500 5H

DN600 6H

DN700 7H

DN800 8H

DN900 9H

DN1000 1T

DN1200 2M

DN1400 4M

DN1600 6M

DN1800 8M

DN2000 0M

Electrode material

SS 316L S

Hastelloy C H

Operating pressure

0.6MPa B

1.0MPa C

1.6MPa D

on request Z

Flange material Companion flange

SS 304 (DN100 PN1.6) No 0

SS 304 (DN100 PN1.6) Carbon steel + welding base 1

SS 304 (DN100 PN1.6) Stainless steel + welding base 2

Process temperature

Standard <130 °C 0

on request Z

37
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
LMF14B
Electromagnetic Flowmeter
(Insertion Type, Battery-operated)
LMF14B – Ordering information continue…

Display LCD & sensor

Integrated T

Remote type R

Communication Power Source

RS485 Built-in lithium battery 01

RS485 12V-24V external power supply 02

GPRS Built-in lithium battery 03

CDMA Built-in lithium battery 04

Power supply

Built-in lithium battery power supply G

Built-in lithium battery-powered + 12V-24V external power supply K

Protection class

IP65 (standard) 0

IP67 1

IP68 (remote type only) 2

Electrical Connector

M20 x 1.5 0

1/2” – 14” NPT 1

Cable length (Remote type only)

Standard 5 meters R5

on request (up to 10 meters) RX

Advantages:

- No External Power Required for Remote Locations (Battery Operated Type)


- Low power consumption, standard conventional lithium battery pack for 5 to 6 years of continuous work.
- Optional external battery can be achieve the maximum battery life more than 10 years, it can be reduce the flow meter
maintenance costs.

More information of battery life 5 year service life for transmitter, data collection every 20 minutes.
The data of flow, for example:
2016/09/19/12:05 100l/s
2016/09/19/12:25 102l/s
2016/09/19/12:45 101l/s

Every 20 minutes, the transmitter will record the time and flow data.
The module will package 3 data, and send the data to data collection server every 1 hour.

This standard data collection and sending frequency in enough for most of application, more frequent of data collection and sending,
more power would be consume by transmitter or module, that would make the service life decrease.

5 year service life for CDMA/GPRS module, data sending every 1 hour.

38
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
Correct Installation of
Electromagnetic Flowmeter

1. Choice of Installation Place


 Choosing no negative pressure in measuring tube;
 Avoiding being installed near motor, transformer, and other strong current equipment, to avoid jammer;
 Avoiding being installed near strong corrosion gas;
 Avoiding being installed in separated place, when measuring mixed fluid;
 Avoiding being under direct sunlight, ambient temperature should be -25-60 °C;
 Choosing place without or less vibration, if too much vibration, fixed support should be installed before and behind the pipe;
 Choosing relative humidity is 5%-90%;
 Avoiding being installed in place which can be exposed to rain or immersed.

2. Demands of straight length: (D is the diameter of flowmeter)


Electromagnetic flowmeter has less demands for straight length forward and backward, usually as for 90 ·c bend, T pattern three
way, reducer, widely open valve, it must have 5D straight length near axis of spindle, not headface of sensor; as for different
aperture valve, such as adjustable aperture valve, it must have 1 OD straight length. As for backward, it only needs 3D straight
length.

When measuring different medium of mixed fluid, distance between mixing point and flowmeter should be
>30D, as following picture shows:

3. Installation and Direction of Flow


Electromagnetic flowmeter can be installed horizontal, vertical, bias to the pipe: When horizontal installation, axis of electrode should
be horizontal, which prevents short insulation of electrodes due to bubble within fluid, and prevents electrodes being covered by
sediment in fluid. Sensor shouldn't be installed in the highest point, to avoid gas accumulation.

When vertical installation, direction of flow should be upward, so that when no flow or small flow, heavier solid particle in fluid will sink,
and lighter material will rise to leave electrode district, when measuring solid and liquid medium, it can avoid rubbing between
sediment of solid and uneven lining. As following picture shows.

Measuring pipe of sensor should be full of fluid, and have some backpressure. In order to prevent negative pressure (damaging
lining), electromagnetic flowmeter can't be installed behind the pump, but before the pump; when bias installation, it must be installed
in rising pipe; when installed in discharged pipe, it must be installed in lower point of pipe.

39
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
Correct Installation of
Electromagnetic Flowmeter

Controlling valve and stopping valve should be installed in downstream sensor, not upstream.

Methods of installing flowmeter in measuring well

40
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
Electromagnetic Flowmeter
Selection Checklist

Please fill & circle as selection. Mark (*) is important must be complete
Customer data
*Company Date
*Name Phone
*Department Mobile
Address Email

Process Characteristics
*Medium

*Conductivity

*Viscosity cP | cSt

Operating Condition
*SI unit kg/h m³/h Nm³/h
*Nom. Flowrate Operating Pressure bar
*Min. Flowrate *Static Pressure bar
*Max Flowrate *Operating Temperature °C

Sizing & Material


Installation method Flange type Insertion type Tri-clamp
*Pipe size (Please fill)
*Pressure rating 6 bar 10 bar 16 bar 25 bar 40 bar Special

*Electrode Material
Platinum Tungsten
SS316 Hastelloy C Titanium Tantalum
Iridium Carbide

*Lining Material
Rubber PP PTFE F46 PFA Special

41
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
Electromagnetic Flowmeter
Selection Checklist

Please fill & circle as selection. Mark (*) is important must be complete
Installation method & Electrical data
Integrated Remote type
Fixed Flange Insertion Type Fixed Flange
External power Built-in battery External power Built-in battery External power

*Power Source External Power Built-in Battery External Battery


*Voltage 220 VAC 24VDC

*Battery Life
6 months 1 year 2 years 3 years 5 years
8 years 10 years Please state

Output signal 4-20mA + pulse HART Modbus Profibus

Accessories (optional)
Built-in temperature sensor Yes No
*Grounding ring (for flange connection only) Yes No
*Cable length (for Remote type only) (Please fill) Meter(s)

Protection
Explosion protection No Ex d IIC T6
Ingress protection IP65 IP67 IP68

42
Electromagnetic Flowmeter - LMF

www.winters.com / www.wintersasia.com
WINTERS INSTRUMENTS
MANUFACTURER OF INDUSTRIAL INSTRUMENTATION

Winters Instruments operates globally and is distributed in over 90 countries. Please contact us for your
nearest Regional Manager.

Corporate – Canada Canada - Calgary USA - Buffalo USA - Houston


Winters Instruments Winters Instruments Winters Instruments Winters Instruments
121 Railside Road 4116 8th Street SE 600 Ensminger Road 10757 Cutten Road, Building 7
Toronto, Ontario Calgary, Alberta Buffalo, New York Houston, Texas
M3A 1B2 T2G 3A7 14150 77066
Tel: 416-444-2345 Tel: 403-723-6645 Tel: 716-874-8700 Tel: 281-880-8607
1-800-WINTERS 1-800-WINTERS 1-800-WINTERS 1-800-WINTERS
Fax: 416-444-8979 Fax: 403-723-6647 Fax: 716-874-8800 Fax: 281-880-8614
[email protected] [email protected] [email protected] [email protected]

Asia Latin America Middle East – North Africa - Europe


Winters Instruments Winters Instruments Winters Instruments
Shanghai WitHub Hi-Tech Alberellos 1916 1° Piso E1 P.O. Box 371722
Business Center, Suite 308 B1640BIN, Martinez Dubai Airport Free Zone Dubai,
No. 333, Hongqiao Road Buenos Aires, Argentina United Arab Emirates
Shanghai 200030 China Tel: 54-11-4733 3003 Tel: 971-4295-9177
Tel: 86-21-6104-2610 Fax: 54-11-4733-0572 Fax: 971-4295-9177
Fax: 86-21-6104-2615 [email protected] [email protected]
[email protected] www.winters.com.ar
www.wintersasia.com

Distributed by:

Download Winters’ literature at www.winters.com


Winters Instruments is IOS 9001:2008 Registered

You might also like