C-More Cable
C-More Cable
C-More Cable
PLC Communications
6
In This Chapter...
Introduction................................................................................................................ 6–2
DirectLOGIC PLCs Password Protection.................................................................... 6–2
PLC Communication Cables & Wiring Diagrams....................................................... 6–5
AutomationDirect PLCs RS-232C Serial:..................................................................... 6–7
AutomationDirect PLCs RS-422A/RS-485A:.............................................................. 6–10
Direct LOGIC Universal Isolated Network Adapter, p/n FA-ISOCON:....................... 6–16
Direct LOGIC Universal Converter, p/n F2-UNICON:............................................... 6–17
RS-422A/RS-485A Multi-Drop Wiring Diagram Examples........................................ 6–18
Allen-Bradley:.......................................................................................................... 6–22
GE:.......................................................................................................................... 6–27
GE VersaMax Micro:................................................................................................ 6–27
Mitsubishi:.............................................................................................................. 6–27
Omron:................................................................................................................... 6–29
Modicon ModBus RS-232:....................................................................................... 6–30
Modicon Micro Series:............................................................................................ 6–30
Modicon ModBus with RJ45:................................................................................... 6–30
Siemens:.................................................................................................................. 6–31
Chapter 6: PLC Communications
Introduction
1 The C-more family of touch panels is capable of communicating with a wide variety of
Programmable Logic Controllers. C-more is capable of communicating over RS232,
2 RS422 and RS485 serial networks as well as Ethernet networks. It communicates with all
AutomationDirect PLC’s utilizing various protocols. C-more also communicates with other
brands of PLCs by their different protocols. The table on the next page lists all of the various
3 PLCs and protocols that can be configured. The page after the protocol table lists the various
serial communication cables that are available to purchase. The rest of this chapter is devoted
4 to show the pin to pin connections of all the available cables plus wiring diagrams that the user
can refer to in order to construct their own cables, along with wiring diagrams of cables that
are not available for purchase. To simplify RS422/RS485 wiring schemes, we have included
5 wiring diagrams showing connections for available terminal connectors such as our ZIPLink
Communication Adapter Module, p/n ZL-CMA15, used for example with our DL-06 and
6 D2-260 PLCs and C-more D-Sub 15-pin to Terminal Block Adapter p/n EA-COMCON-3.
If you have difficulty determining whether the particular PLC and/or protocol you are using
7 will work with the C-more series of touch panels, please contact our technical support group
at 770-844-4200
11 C-more
Touch Panel
12
DL-06 PLC
13
14
C-more to
A Direct LOGIC
VGA 15-pin port
Port 2
B serial cable
p/n EA-2CBL-1
C
D
6-2 ®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20
Chapter 6: PLC Communications
all
K-Sequence
Direct NET
3
DL05/DL06
H0-ECOM/H0-ECOM100
Modbus (Koyo addressing)
Direct LOGIC Ethernet
4
DL105 all K-Sequence
D2-230 K-Sequence 5
K-Sequence
D2-240
Direct NET
K-Sequence
6
DL205 D2-250/D2-250-1/D2-260 Direct NET
Modbus (Koyo addressing)
7
Direct NET
D2-240/D2-250-1/D2-260
Using DCM Modbus (Koyo addressing) 8
H2-ECOM/H2-ECOM100 Direct LOGIC Ethernet
D3-330/330P (Requires the use of a Data Communications Unit)
D3-340
Direct NET
Direct NET
9
AutomationDirect
DL305 D3-350
K-Sequence
Direct NET
10
Modbus (Koyo addressing)
D3-350 DCM
Direct NET 11
Modbus (Koyo addressing)
D4-430
K-Sequence
Direct NET
12
D4-440
K-Sequence
Direct NET
13
K-Sequence
DL405
D4-450 Direct NET 14
Modbus (Koyo addressing)
GS Drives
GS Drives Serial C
GS Drives TCP/IP (GS-EDRV)
SOLO Temperature Controllers SOLO Temperature Controller D
PLC Compatibility Table continued on the next page.
®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20 6-3
Chapter 6: PLC Communications
6 MicroLogix 1100, 1400 and SLC 5/05, via native Ethernet port EtherNet/IP Client
MicroLogix 1000, 1100, 1200, 1400, 1500, SLC 5-03/04/05, all via ENI adapter
8 Mitsubishi
Q02, Q02H, Q06H, Q12H, Q25H
Q, QnA Serial
Q CPU
QnA Serial
9 Q, Qna Ethernet
984 CPU, Quantum 113 CPU, AEG Modicon Micro Series 110 CPU: 311-xx, 411-xx,
QnA Ethernet
Modbus RTU
512-xx, 612-xx
10 Modicon
Other devices using Modicon Modbus addressing
Modbus RTU
Modbus TCP/IP
11 Omron
C200 Adapter, C500
CJ1/CS1 Serial
Host Link
FINS
12 CJ1/CS1 Ethernet
S7-200 CPU, RS-485 Serial PPI
Siemens
13 S7-200 CPU, S7-300 CPU, S7-1200 CPU; Ethernet Ethernet ISO over TCP
14
A
B
C
D
6-4 ®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20
Chapter 6: PLC Communications
®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20 6-5
Chapter 6: PLC Communications
5
6
7 Part No. EA-MLOGIX-CBL Part No. EA-SLC-232-CBL
8
9
10
11 Part No. EA-PLC5-232-CBL Part No. EA-DH485-CBL
12
13
14
A Part No. EA-90-30-CBL Part No. EA-MITSU-CBL
B
C
D Part No. EA-MITSU-CBL-1 Part No. EA-OMRON-CBL
6-6 ®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20
Chapter 6: PLC Communications
TXD 4
Wiring Diagram
3 RXD
8 = do not use
7 = do not use
6 = do not use
(male)
15
15 = do not use
14 = do not use
13 = do not use
6
3 = RXD 5 = Logic GND
7
3 2 12 = do not use
4 = TXD RXD TXD
4 = do not use 11 = do not use
5 = do not use GND 1 5 3 = RXD (232C) 10 = do not use
123456
6 = do not use 1 2 = TXD (232C) 9 = do not use
shield 1
1 = Frame GND
Note: Use the above wiring diagram if you need to make your own cable. We recommend using 22 AWG shielded cable. 8
AutomationDirect PLCs RS-232C Serial: EA-2CBL-1 9
Direct Logic PLC (VGA style) 15-pin HD port:
To PLC
15-Pin HD Port
D2-250, D2-250-1, D2-260, DL06
RS-232C (p/n EA-2CBL-1)
To C-more Touch Panel
Serial Port2 10
15-pin Wiring Diagram
11
15-pin
HD D-sub
8 = do not use
7 = Sig GND
(male)
15
15 = do not use
14 = do not use
TXD
RXD
2
3
3 RXD
2 TXD
8 = do not use
7 = do not use
D-sub
(male) 15 = do not use
15 14 = do not use
12
6 = do not use 13 = do not use GND 7 5 6 = donot use 13 = do not use
5 = CTS
4 = RTS
3 = RXD 1 6
12 = do not use
11 = do not use RTS
10 = do not use CTS
4
5
5 = Logic GND
4 = do not use
3 = RXD (232C)
12 = do not use
11 = do not use
10 = do not use
13
2 = TXD 9 = do not use 2 = TXD (232C) 1 9 = do not use
1 = +5 VDC - N/C
HD = High Density shield 1 1 = Frame GND
Note: Use the above wiring diagram if you need to make your own cable. We recommend using 22 AWG shielded cable.
14
A
B
C
D
®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20 6-7
Chapter 6: PLC Communications
2 To PLC
RJ11 Port
RS-232C (p/n EA-3CBL) Panel PLC Port
3 RJ11 4-pin
Phone Plug
15-pin
D-sub
(4P4C) Wiring Diagram 8 = do not use (male) 15 = do not use
4 1 = RXD
2 = TXD
TXD 2
1
3
2
RXD
7 = do not use
6 = do not use
5 = Logic GND
14 = do not use
15 13 = do not use
12 = do not use
RXD TXD
3 = do not use 4 = do not use 11 = do not use
5 4 = Sig ground 1234
GND 4
shield
5
1
3 = RXD (232C)
2 = TXD (232C)
1 = Frame GND
1
10 = do not use
9 = do not use
6 Note: Use the above wiring diagram if you need to make your own cable. We recommend using 22 AWG shielded cable.
7
8
9
10
11
12
13
14
A
B
C
D
6-8 ®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20
Chapter 6: PLC Communications
6
2 = TXD (232C) 1 9 = do not use
1 = YOP Sense 1 7 1 = Frame GND
CTS
See PLC user manual YOM 8
for pin out details.
1
shield
Note: Use the above wiring diagram if you need to make your own cable. We recommend using 22 AWG shielded cable. 7
8
EA-4CBL-2
To PLC
25-Pin Port
Direct Logic PLC 25-pin D-sub port:
DL405, D3-350, DL305 DCU, and all DCMs,
To C-more Touch
Panel PLC Port
9
RS-232C (p/n EA-4CBL-2)
10
11
25-pin Wiring Diagram 15-pin
D-sub D-sub
13 = do not use (male) 25 = do not use TXD 2 3 RXD 8 = do not use
12 = do not use (male) 15 = do not use
25 24 = do not use 3 2 7 = do not use 14 = do not use
23 = do not use RXD
12
11 = do not use TXD 15 13 = do not use
10 = do not use 6 = do not use
22 = do not use GND 7 5
5 = Logic GND 12 = do not use
9 = do not use 21 = do not use
8 = do not use 4 4 = do not use 11 = do not use
7 = Signal GND 20 = do not use RTS 3 = RXD (232C) 10 = do not use
13
19 = do not use CTS 5
6 = do not use 2 = TXD (232C) 1 9 = do not use
5 = CTS 18 = do not use 1 = Frame GND
4 = RTS 17 = do not use shield 1
3 = RXD 16 = do not use
2 = TXD
1 = do not use
1 15 = do not use
14 = do not use
Note: Use the above wiring diagram if you need to make your own cable. We recommend using 22 AWG shielded cable.
14
A
B
C
D
®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20 6-9
Chapter 6: PLC Communications
3 To PLC Direct LOGIC DL-06, D2-250, D2-250-1, D2-260 (all Port 2) To C-more Touch
Panel PLC Port
15-Pin Port RS-422A
User Constructed
4
5
Wiring Diagram 13
15-pin Term. 15-pin
HD D-sub D-sub
TXD+ 9 9 RD+
(male) 8 = do not use (male) 15 = do not use
TXD– 10 10 RD– 7 = do not use 14 = do not use
6 8 = do not use
7 = Sig GND
6 = RXD–
15
15 = CTS–
14 = CTS+
RXD+
RXD–
13
6
11
12
SD+
6 = do not use
5 = Logic GND
SD– 4 = do not use
15
13 = Termination
12 = SD– (RS422)
11 = SD+ (RS422)
5 = do not use 13 = RXD+
7 5 3 = do not use 10 = RD– (RS422)
7 4 = do not use
3 = do not use
2 = do not use
1 6
12 = RTS-
11 = RTS+
10 = TXD–
GND
RTS– 12
15
2 = do not use 1
1 = Frame GND
9 = RD+ (RS422)
9 = TXD+ CTS–
1 = do not use
8 RTS+
CTS+
11
14
shield 1
9 Note: Use the above wiring diagram to make your own cable. We recommend Belden 8103 shielded cable or equivalent.
10 To PLC
25-Pin Port
Direct LOGIC D2-DCM*, D3-DCM* & D4-DCM* To C-more Touch
RS-422A Panel PLC Port
11 User Constructed
12 13 = CTS–
25-pin
D-sub
(male)
25 = do not use
24 = do not use TXD+ 14
Wiring Diagram 13 Term.
9 RD+
15-pin
D-sub
8 = do not use (male) 15 = do not use
12 = CTS+ 23 = do not use
13 11 = RTS–
10 = RTS+
9 = do not use
25 22 = do not use TXD–
21 = do not use RXD+ 17
20 = do not use
15 10 RD– 7 = do not use
11 SD+ 6 = do not use
5 = Logic GND
15
14 = do not use
13 = Termination
12 = SD– (RS422)
8 = do not use 16 12 SD– 4 = do not use
19 = do not use RXD– 11 = SD+ (RS422)
14 7=0V
6 = do not use
5 = do not use
18 = do not use
17 = RXD+
(RS422)
0V
RTS–
7
11
5 3 = do not use
2 = do not use 1
1 = Frame GND
10 = RD– (RS422)
9 = RD+ (RS422)
4 = do not use 13
16 = RXD–
A 3 = do not use CTS–
2 = do not use (RS422)
RTS+ 10 * Note: The DCM modules must be set for:
1 = do not use 1 15 = TXD–
CTS+ 12 Direct NET Slave, HEX mode.
(RS422)
B 14 = TXD+
(RS422)
shield 1
Note: Use the above wiring diagram to make your own cable. We recommend Belden 8103 shielded cable or equivalent.
C NOTE: The RS-422 wiring diagrams shown above are not for multi-drop networks involving connecting more
D than one PLC to a panel. Refer to the wiring diagram example on page 6-18 if more than one PLC will be
connected to a panel.
6-10 ®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20
Chapter 6: PLC Communications
2
25-pin
D-sub
14
Wiring Diagram 13
9
Term. 15-pin
D-sub
3
13 = do not use (male) 25 = do not use TXD+ RD+
12 = do not use 8 = do not use (male) 15 = do not use
11 = CTS+
10 = RXD–
(RS422)
24 = do not use
25 23 = CTS–
22 = do not use
TXD–
RXD+
16
9
10
11
RD– 7 = do not use
SD+
6 = do not use
5 = Logic GND
15
14 = do not use
13 = Termination
12 = SD– (RS422)
4
21 = do not use 10 12
9 = RXD+ RXD– SD– 4 = do not use 11 = SD+ (RS422)
(RS422)
8 = do not use
7=0V
20 = do not use
19 = RTS+
18 = RTS–
0V
RTS–
7
18
5 3 = do not use
2 = do not use 1
1 = Frame GND
10 = RD– (RS422)
9 = RD+ (RS422) 5
6 = do not use 17 = do not use
23
5 = do not use
4 = do not use
3 = do not use 1
16 = TXD–
(RS422)
15 = do not use
CTS–
RTS+ 19
11
6
2 = do not use 14 = TXD+ CTS+
1 = do not use (RS422) shield 1
Note: Use the above wiring diagram to make your own cable. We recommend Belden 8103 shielded cable or equivalent.
7
8
User Constructed
To PLC
25-Pin Port
Direct LOGIC D4-450 Port 3 To C-more Touch 9
RS-422A Panel PLC Port
RTS and CTS are not present on this port.
10
13 = TXD–
25-pin
D-sub
(male)
25 = RXD–
(RS422) TXD+ 12
Wiring Diagram 13
9
Term.
RD+
15-pin
D-sub 11
(RS422) 8 = do not use (male) 15 = do not use
12 = TXD+ 24 = RXD+ 13 10
(RS422)
11 = do not use
10 = do not use
25 (RS422)
23 = do not use
22 = do not use
TXD–
RXD+ 24
25
11
12
RD– 7 = do not use
SD+
6 = do not use
5 = Logic GND
15
14 = do not use
13 = Termination
12 = SD– (RS422)
12
9 = do not use RXD– SD– 4 = do not use 11 = SD+ (RS422)
21 = do not use
8 = do not use
7=0V
6 = do not use
20 = do not use
19 = do not use
18 = do not use
0V 7
shield
5
1
3 = do not use
2 = do not use 1
1 = Frame GND
10 = RD– (RS422)
9 = RD+ (RS422) 13
5 = do not use
14
4 = do not use 17 = do not use
3 = do not use 16 = do not use
2 = do not use 1 15 = do not use
1 = do not use 14 = do not use
Note: Use the above wiring diagram to make your own cable. We recommend Belden 8103 shielded cable or equivalent.
A
NOTE: The RS-422 wiring diagrams shown above are not for multi-drop networks involving connecting more
B
than one PLC to a panel. Refer to the wiring diagram example on page 6-18 if more than one PLC will be
connected to a panel. C
D
®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20 6-11
Chapter 6: PLC Communications
5
7 5 3 = do not use 10 = RD– (RS485)
4 = do not use 12 = RTS- GND
2 = do not use 1 9 = RD+ (RS485)
3 = do not use 1 6 11 = RTS+ RTS– 12
1 = Frame GND
2 = do not use 10 = TXD– 15
9 = TXD+ CTS–
1 = do not use
6 RTS+
CTS+
11
14
shield 1
7 Note: Use the above wiring diagram to make your own cable. We recommend Belden 9842 shielded cable or equivalent.
8 NOTE: The RS-485 wiring diagram shown above is not for multi-drop networks involving connecting more
than one PLC to a panel. Refer to the wiring diagram example on page 6-18 if more than one PLC will be
9 connected to a panel.
10
11
12
13
14
A
B
C
D
6-12 ®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20
Chapter 6: PLC Communications
RS422/485
RXD
TXD
232
RS-422/485 TX–
RS-422/485 RX+
SD–
SD+ 4
TX+
RX+
TXD
RXD
+5V
TX-
RX-
ZL-CMA15L
shield
See ZL-CMA15L specifications on
TERM EA-COMCON-3
5
termination resistor jumper.
Note: Use the above wiring diagram to make your own cable. We recommend Belden 8103 shielded cable or equivalent. 6
7
Direct LOGIC ZIPLink ZL-CMA15L Adapter Module to EA-COMCON-3 Terminal Block Adapter
RS-422A – PLC D2-250 (-1), D2-260 or DL06 – Port 2
Terminal Block Adapter
8
plugs into C-more 15-pin
9
RS-232 RXD
PLC Serial Comm. Port
RS-232 TXD Wiring Diagram
TERMINATE +5V
ZL-CMA15L
RXD
SIGNAL GND
RS-422/485 RX–
GND
SD–
10
RS-422/485 RX+ SD+
RS422/485
TXD
232
RS-422/485 TX– RD–
11
TX+
RX+
TXD
RXD
+5V
TX-
RX-
SG
Note: Use the above wiring diagram to make your own cable. We recommend Belden 9842 shielded cable or equivalent.
13
NOTE: The RS-422 and RS-485 wiring diagrams shown above are not for multi-drop networks involving
connecting more than one PLC to a panel. Refer to the wiring diagram examples starting on page 6-18 if
14
more than one PLC will be connected to a panel.
A
B
C
D
®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20 6-13
Chapter 6: PLC Communications
3 SIGNAL GND
TXD / RXD –
GND
RD –
*
4 TXD / RXD +
Productivity3000
SD –
SD +
PS485 Port RD +
5 * 120 Ω resistor
shield TERM
EA-COMCON-3
Note: Use the above wiring diagram to make your own cable. We recommend Belden 9842 shielded cable or equivalent.
6
7
8
AutomationDirect Productivity PAC
9 Removable Connector
included with
Productivity3000 CPU
RS-485
To C-more Touch
Panel Serial Port2
10
Wiring Diagram 13 15-pin
11
Term.
D-sub
TXD+ / RXD+ 3 9 RD+
8 = do not use (male) 15 = do not use
TXD+ / RXD+ + Term. 11 SD+ 7 = do not use 14 = do not use
15
13 shield 1
2 = do not use 1
1 = Frame GND
9 = RD+ (RS485)
Note: Use the above wiring diagram to make your own cable. We recommend Belden 9842 shielded cable or equivalent.
Use 120 ohm resistors as termination resistors (Term.)
14
A
B
C
NOTE: The RS-485 wiring diagrams shown above are not for multi-drop networks involving connecting more
D than one PLC to a panel. Refer to the wiring diagram examples starting on page 6-18 if more than one PLC
will be connected to a panel.
6-14 ®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20
Chapter 6: PLC Communications
4
RD+
Signal A 8 = do not use (male) 15 = do not use
RS-485 Signal A + Term. 11 SD+ 7 = do not use 14 = do not use
15
RS-485 8 10 6 = do not use 13 = Termination
RS-485 Signal B - Signal B
RD–
5 = Logic GND 12 = SD– (RS485)
5
12 SD– 4 = do not use
Logic Ground LG 11 = SD+ (RS485)
Logic 5 5 3 = do not use 10 = RD– (RS485)
Ground 2 = do not use 1 9 = RD+ (RS485)
shield 1 1 = Frame GND
Note: Use the above wiring diagram to make your own cable. We recommend Belden 9842 shielded cable or equivalent.
Use 120 ohm resistors as termination resistors (Term.)
6
7
8
9
10
11
12
13
14
A
B
C
NOTE: The RS-422 and RS-485 wiring diagrams shown above are not for multi-drop networks involving
connecting more than one PLC to a panel. Refer to the wiring diagram examples starting on page 6-18 if
more than one PLC will be connected to a panel.
D
®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20 6-15
Chapter 6: PLC Communications
3 RX–
RX+
SD–
SD+
RXD
4 TXD
TXD EN
TX–
TX+
RD–
RD+
B TXD shield TERM
5
RXD
CTS Ground the shield only at the equipment
C-A end where the FA-ISOCON is located. EA-COMCON-3
C +V
C-A
D
6
TX+
TX–
RX– See FA-ISOCON specificaitons to
RX+ properly configure the adapter. Note: When using multiple PLCs
C-B connected to one C-more touch
panel, only jumper the Term
7 FA-ISOCON
terminal to the RD+ terminal
when the panel is the last device
at one end of the network.
8 Port 2
9
10 Modular cable included
with the FA-ISOCON
PW
RU
CP
TX1
RX
1
R
N
U
DL05 PLC
TX2
11
2
RX
12 Note: Use the above wiring diagram to make your own cable. We recommend Belden 8103 shielded cable or equivalent.
13
14
A
B
C
D
6-16 ®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20
Chapter 6: PLC Communications
8
CPU TERM
D2-240 PLC CH 1
CH 2
9
CH 3
CH 4
10
PORT 1
PORT 2
®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20 6-17
Chapter 6: PLC Communications
TX+
RX+
TXD
RXD
+5V
TX-
RX-
SG
(ZL-CMA15L shown) across RS-422 connection)
Port 2
6 ZL-CMA15L
Shielded Cable
When connecting to a DirectLogic PLC
RXD
Cable Adapter
7
TXD
TXD
RXD
+5V
TX-
RX-
SG
(ZL-CMA15L shown)
Shielded Cable
8
9
10 Notes: 1. We recommend Belden 8103 shielded cable or equivalent.
2. Wiring Diagram for this example, ZL-CMA15(L)
To DL06 PLC port 2 To D2-250-1 PLC port 2
11 (example RS-422 connection) (example RS-422 connection)
RXD+
RXD+
RXD–
RXD–
TXD+
TXD+
RTS+
CTS+
RTS+
CTS+
TXD–
TXD–
RTS–
CTS–
RTS–
CTS–
GND
GND
12 7 10 9 6
*
13 11 14 12 15 7 10 9 6 13 11 14 12 15
13 7 = Sig GND
15-pin
HD D-sub
8 = do not use (male)
15
15 = CTS–
14 = CTS+
6 = RXD– 13 = RXD+
14
5 = do not use 12 = RTS-
4 = do not use 11 = RTS+
3 = do not use 10 = TXD–
2 = do not use 1 9 = TXD+
1 = do not use 6
A
HD = High Density
RXD+ RXD+
RXD– RXD–
B TXD+
TXD–
TXD+
TXD–
Signal GND Signal GND
6-18 ®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20
Chapter 6: PLC Communications
TERM
N-3
UST
IND
ICS
CO
RD+
ON
-COM
CTR
RD–
ELE
O
EA
SD+
KOY
SD–
GND
ZL-CMA15L
RXD
Cable Adapter
7
TXD
RS422/485 232
TX+
RX+
TXD
RXD
+5V
TX-
RX-
SG
(ZL-CMA15L shown)
Shielded Cable
Shielded Cable
8
9
Notes: 1. We recommend Belden 8103 shielded cable or equivalent.
2. Wiring Diagram for this example, ZL-CMA15(L) 10
To DL06 PLC port 2 To C-more Touch Panel
(example RS-422 connection)
11
* Term.
RXD+
RXD–
TXD+
RTS+
CTS+
TXD–
RTS–
CTS–
SHD
RD+
RD–
SD+
GND
SD–
GND
EA-COMCON-3
7 10 9 6 13 11 14 12 15 5 10 9 12 11 13 1
12
6 = RXD–
15-pin
HD D-sub
8 = do not use (male)
7 = Sig GND
15
15 = CTS–
14 = CTS+
13 = RXD+
8 = do not use
15-pin
D-sub 15 = do not use
13
7 = do not use (male) 14 = do not use
5 = do not use 12 = RTS-
14
6 = do not use 15 13 = Termination
4 = do not use 11 = RTS+ 5 = Logic GND 12 = SD– (RS422)
3 = do not use 10 = TXD– 4 = do not use 11 = SD+ (RS422)
2 = do not use 1 9 = TXD+ 3 = do not use 10 = RD– (RS422)
1 = do not use 6
2 = do not use 9 = RD+ (RS422)
HD = High Density 1 = Frame GND 1
RXD+ RXD+ A
RXD– RXD–
TXD+
TXD–
TXD+
TXD–
B
Signal GND Signal GND
shield
* Termination resistors required at both ends of the
network receive data signals to match the impedance
shield
C
of the cable (between 100 and 500 ohms). Jumper pin
Typical RS-422 Multi-Drop Wiring Diagram (cont-d)
using DirectLogic pin numbers to illustrate
13 to 9 on the C-more Touch Panel 15-pin connector
to place the 120 internal resistor into the network. If
the cable impedance is different, then use an external
resistor matched to the cable impedance.
D
®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20 6-19
Chapter 6: PLC Communications
TX+
RX+
TXD
RXD
+5V
TX-
RX-
SG
(ZL-CMA15L shown) across RS-422 connection)
Port 2
6 ZL-CMA15L
Shielded Cable
When connecting to a DirectLogic PLC
RXD
Cable Adapter
7
TXD
TXD
RXD
+5V
TX-
RX-
SG
(ZL-CMA15L shown)
Shielded Cable
8
9
10 Notes: 1. We recommend Belden 9842 shielded cable or equivalent.
2. Wiring Diagram for this example, ZL-CMA15(L)
12
RXD+
RXD+
RXD–
RXD–
TXD+
RTS+
CTS+
TXD+
RTS+
CTS+
TXD–
RTS–
CTS–
TXD–
RTS–
CTS–
GND
GND
7 6 10 13 9 11 14 12 15 7 6 10 13 9 11 14 12 15
13 *
15-pin
HD D-sub
A
3 = do not use 10 = TXD–
2 = do not use 1 9 = TXD+
1 = do not use 6
HD = High Density
B TXD– / RXD–
TXD+ / RXD+
TXD– / RXD–
TXD+ / RXD+
C
shield
6-20 ®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20
Chapter 6: PLC Communications
TERM
N-3
UST
IND
ICS
CO
RD+
ON
-COM
CTR
RD–
ELE
O
EA
SD+
KOY
SD–
GND
ZL-CMA15L
RXD
Cable Adapter
7
TXD
RS422/485 232
TX+
RX+
TXD
RXD
+5V
TX-
RX-
SG
(ZL-CMA15L shown)
Shielded Cable
Shielded Cable
8
9
Notes: 1. We recommend Belden 9842 shielded cable or equivalent.
2. Wiring Diagram for this example, ZL-CMA15(L) 10
To DL06 PLC port 2 To C-more Touch Panel
11
(example RS-485 connection)
* Term.
12
RXD+
RXD–
TXD+
RTS+
CTS+
TXD–
RTS–
CTS–
SHD
RD+
RD–
SD+
GND
GND
SD–
EA-COMCON-3
7 6 10 13 9 11 14 12 15 5 10 12 9 11 13 1
15-pin
13
HD D-sub
15-pin
14
8 = do not use (male) 15 = CTS–
7 = Sig GND 14 = CTS+ 8 = do not use D-sub 15 = do not use
6 = RXD– 15 13 = RXD+ 7 = do not use (male) 14 = do not use
5 = do not use 12 = RTS- 6 = do not use 15 13 = Termination
4 = do not use 11 = RTS+ 5 = Logic GND 12 = SD– (RS485)
3 = do not use 10 = TXD– 4 = do not use 11 = SD+ (RS485)
2 = do not use 1
1 = do not use 6
9 = TXD+
HD = High Density
3 = do not use
2 = do not use
1 = Frame GND 1
10 = RD– (RS485)
9 = RD+ (RS485)
A
TXD– / RXD–
TXD+ / RXD+
TXD– / RXD–
TXD+ / RXD+ B
Signal GND Signal GND
C
shield shield
®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20 6-21
Chapter 6: PLC Communications
Allen-Bradley:
EA-MLOGIX-CBL
1 Allen-Bradley MicroLogix™ 1000/1100/1200/1400/1500 To C-more Touch
To AB MicroLogix RS-232
RS-232C (p/n EA-MLOGIX-CBL) Panel PLC Port
2 communication channel
3 1 = do not use
2 = Sig GND
Mini Din
8-pin Male Wiring Diagram 8 = do not use
15-pin
D-sub
(male) 15 = do not use
7 = do not use 14 = do not use
4
3 = do not use TXD 7 3 RXD 6 = do not use 15 13 = do not use
0.290”
4 = RXD 6 7 8
5 = Logic GND 12 = do not use
3 4 5
RXD 4 2
5 = do not use 1 2
TXD
4 = do not use 11 = do not use
6 = do not use GND 2 5 3 = RXD (232C) 10 = do not use
0.35”
5 7 = TXD
8 = do not use
DIA. Nonstandard
keying shield 1 2 = TXD (232C) 1
1 = Frame GND
9 = do not use
Note: Use the above wiring diagram if you need to make your own cable. We recommend using 22 AWG shielded cable.
6
EA-SLC-232-CBL
7 To PLC
9-Pin Port
Allen-Bradley SLC 5-03/04/05, ControlLogix, CompactLogix,
FlexLogix, MicroLogix, DF1, RS-232C (p/n EA-SLC-232-CBL)
To C-more Touch
Panel PLC Port
8
9 9-pin
D-sub
(female) Wiring Diagram
15-pin
D-sub
8 = do not use (male)
7 = do not use
15 = do not use
14 = do not use
1 = do not use 1 3 3
10
6 = do not use TXD RXD 6 = do not use 15 13 = do not use
2 = RXD 7 = do not use 5 = Logic GND
2 2 12 = do not use
3 = TXD 8 = do not use RXD TXD
4 = do not use 11 = do not use
4 = do not use 9 = do not use GND 5 5 3 = RXD (232C) 10 = do not use
5 = Signal GND 9
12
EA-PLC5-232-CBL
13 To PLC
25-Pin Port
Allen-Bradley PLC5 DF1
RS-232C (p/n EA-PLC5-232-CBL)
To C-more Touch
Panel PLC Port
14
Wiring Diagram
A 25-pin
D-sub
13 = do not use (male) 25 = do not use TXD 2
12 = do not use
3 RXD 8 = do not use
15-pin
D-sub
(male) 15 = do not use
25 24 = do not use 3 2 TXD 7 = do not use 14 = do not use
11 = do not use 23 = do not use RXD
B 10 = do not use
9 = do not use
8 = do not use
22 = do not use GND 7
21 = do not use
shield
5
1
6
5
=
=
do not
Logic
use
GND
4 = do not use
15 13 = do not use
12 = do not use
11 = do not use
7 = Signal GND 20 = do not use 3 = RXD (232C) 10 = do not use
C 6 = do not use
5 = do not use
4 = do not use
19 = do not use
18 = do not use
17 = do not use
2 = TXD (232C) 1
1 = Frame GND
9 = do not use
D 2 = TXD
1 = do not use
1 15 = do not use
14 = do not use
Note: Use the above wiring diagram if you need to make your own cable. We recommend using 22 AWG shielded cable.
6-22 ®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20
Chapter 6: PLC Communications
Wiring Diagram 2
RJ45 8-pin
1 = TXD/RXD+
2 = TXD/RXD–
Phone Plug
(8P8C)
TXD/RXD+ 1
13
9
Term.
RD+
15-pin
D-sub
8 = do not use (male) 15 = do not use
3
3 = do not use 2 10 7 = do not use 14 = do not use
4 = Signal GND
5 = LE
6 = do not use
TXD/RXD–
11
12
RD–
SD+
6 = LE
5 = Logic GND
4 = do not use
15 13 = Termination
12 = SD– (RS485)
11 = SD+ (RS485)
4
SD– 3 = do not use 10 = RD– (RS485)
5
7 = Signal GND
5 6 LE * 2 = do not use 1 9 = RD+ (RS485)
8 = do not use LE *
4 1 = Frame GND
GND
7 5 * Note: The LE signal is wired in the cable
6
GND
as shown, but not required for
shield 1 point-to-point communications.
Note: Use the above wiring diagram if you need to make your own cable. We recommend Belden 9842 shielded cable or equivalent.
Allen-Bradley SLC500™, 5/01, /02, /03 DH-485/AIC to Multiple C-more Touch Panels 7
RS-485A (using C-more cable p/n EA-DH485-CBL)
DH-485 DH-485
9
10
Peripheral Peripheral
J2 J2
CPU CPU
J1 J1
AB 1747-AIC
DH485 Link Coupler
AB 1747-AIC
DH485 Link Coupler
11
AB 1747-C11 A
Cable 12
13
14
C-more
Touch Panel
C-more
Touch Panel
A
B
C-more
EA-DH485-CBL
Cable
C-more
EA-DH485-CBL
Cable
C
Note: The above diagram shows connecting multiple C-more touch panels to an Allen-Bradley DH485/AIC network
using the AB DH485 Link Coupler, p/n 1747-AIC. Select the “Allen-Bradly DH485/AIC SLC500 MircroLogix” driver
in the C-more Programming Software when starting the project. Also, set the AB channel configuration for DH485.
D
®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20 6-23
Chapter 6: PLC Communications
Allen-Bradley (cont’d):
1 Allen-Bradley SLC500™ 5/03 DH-485/AIC to Multiple C-more Touch Panels
(using C-more cables p/n EA-MLOGIX-CBL, EA-SLC-232-CBL)
3 PLC Controller
4 Channel 0 must be
set to DH485.
5 AB 1761-NET-AIC
AIC + Advanced
Interface Converter
AB 1761-NET-AIC
AIC + Advanced
Interface Converter
6 C-more
EA-MLOGIX-CBL
Cable
7 AB 1747-CP3
RS-232 Cable
8 To additional
C-more
Touch Panel
9 C-more
Touch Panel
C-more
Touch Panel
10
C-more
11 EA-MLOGIX-CBL
Cable
C-more
EA-SLC-232-CBL
Cable
12 Note: The above diagram shows connecting multiple C-more touch panels to an Allen-Bradley DH485/AIC network using the
AB AIC+ Advanced Interface Converter, p/n 1761-NET-AIC. Select the “Allen-Bradly DH485/AIC SLC500 MircroLogix” driver
in the C-more Programming Software when starting the project. Also, set the AB channel configuration for DH485.
13
14
A
B
C
D
6-24 ®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20
Chapter 6: PLC Communications
Allen-Bradley (cont’d):
Multiple Allen-Bradley PLCs connected to multiple C-more Touch Panels
(using AB Ethernet Network Interface p/n 761-NET-ENI with EtherNet/IP protocol)
1
Allen-Bradley
SLC 5/03 Modular
Allen-Bradley
MicroLogix 1000
Allen-Bradley
MicroLogix 1500
PLC Controller
2
PLC Controller PLC Controller
3
4
5
AB mini DIN to D-shell AB mini DIN to mini DIN
cable p/n 1761-CBL-AP00 cable p/n 1761-CBL-AM00
6
ETHERNET
RS232
FAULT
Ethernet
TX/RX ETHERNET
RS232
FAULT
Hub or Switch
IP
10/100 Base-T
TX/RX
PWR
7
ETHERNET CABLE IP
RS232
FAULT
EXTERNAL
PWR
TX/RX CABLE
EXTERNAL
IP
AB 1761-NET-ENI
8
PWR
AB 1761-NET-ENI
CABLE
EXTERNAL
Ethernet/IP
Network
AB 1761-NET-ENI
9
C-more
Touch Panel 10
C-more
Touch Panel
11
12
13
14
A
B
C
D
®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20 6-25
Chapter 6: PLC Communications
2
25-pin Wiring Diagram
3
15-pin
D-sub D-sub
13 = do not use (male) 25 = do not use TXD + 2 10 RD – 8 = do not use
12 = do not use (male) 15 = do not use
25 24 = do not use 3 12 7 = do not use 14 = do not use
11 = do not use 23 = do not use RXD + SD – 15 13 = do not use
4 10 = do not use
9 = do not use
8 = do not use
22 = do not use GND
21 = do not use
20 = do not use
TXD – 14
7 5
6 = do not use
5 = Logic GND
9 RD + 4 = do not use
12 = SD –
11 = SD +
7 = Signal GND 11 SD + 3 = do not use 10 = RD –
19 = do not use RXD – 16
5 6 = do not use
5 = do not use
4 = do not use
3 = RXD +
18 = do not use
17 = do not use
16 = RXD –
shield 1
2 = do not use 1
1 = Frame GND
9 = RD +
2 = TXD +
6 1 15 = do not use
1 = do not use 14 = TXD –
Notes:
1. Polarities must be swapped.
8
9
10
11
12
13
14
A
B
C
D
6-26 ®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20
Chapter 6: PLC Communications
GE: EA-90-30-CBL
To PLC
15-Pin Port
GE 90/30 and 90/70 15-pin D-sub port,
RS-422A (p/n EA-90-30-CBL)
To C-more Touch
Panel PLC Port 1
2
Wiring Diagram 13
15-pin Term. 15-pin
8 = CTS(B’)
7 = Logic GND
D-sub
(male)
15
15 = CTS(A’)
14 = do not use
SD(B)
SD(A)
13
12
9
10
RD+
D-sub
8 = do not use (male) 15 = do not use
RD– 7 = do not use 14 = do not use
3
6 = do not use 13 = SD(B) 15
11 11 SD+ 6 = do not use
4
5 = +5V 12 = SD(A) RD(B’) 13 = Termination
5 = Logic GND 12 = SD– (RS422)
4 = do not use 11 = RD(B’) RD(A’) 10 12 SD– 4 = do not use
3 = do not use 10 = RD(A’) 11 = SD+ (RS422)
GND 7 5 3 = do not use 10 = RD– (RS422)
2 = do not use 9 = do not use
5
2 = do not use 1 9 = RD+ (RS422)
1 = do not use 1 CTS(B’) 8
1 = Frame GND
CTS(A’) 15
+5V 5
shield 1
Note: Use the above wiring diagram if you need to make your own cable. We recommend Belden 8103 shielded cable or equivalent.
6
GE VersaMax Micro: User Constructed 7
GE VersaMax Micro Port 1 To C-more Touch
To PLC
RJ45 Port 1 RS-232C
Panel PLC Port
8
RJ45 8-pin
Phone Plug Wiring Diagram
15-pin
D-sub
9
1 = RTS (8P8C) (male)
10
2 = CTS 8 = do not use 15 = do not use
TXD 4 3 RXD 7 = do not use
3 = RXD 15 14 = do not use
4 = TXD RXD 3 2 TXD 6 = donot use 13 = do not use
5 = DCD 8 5 5 = Logic GND 12 = do not use
11
6 = DTR GND 4 = do not use 11 = do not use
7 = +5V shield 1 3 = RXD (232C) 10 = do not use
8 = GND 2 = TXD (232C) 1 9 = do not use
1 = Frame GND
Note: Use the above wiring diagram to make your own cable. We recommend using 22 AWG shielded cable.
12
Mitsubishi: EA-MITSU-CBL
To PLC
25-Pin Port
Mitsubishi FX Series 25-pin D-sub port,
RS-422A (p/n EA-MITSU-CBL)
To C-more Touch
Panel PLC Port
13
14
13 = do not use
25-pin
D-sub
(male) 25 = do not use SD+ 3
Wiring Diagram 13 Term.
9 RD+
8 = do not use
15-pin
D-sub
(male) 15 = do not use
A
12 = do not use 25 24 = do not use SD– 16 10 RD– 7 = do not use
B
11 = do not use 23 = do not use 14 = do not use
15
10 = do not use 22 = do not use RD+ 2 11 SD+ 6 = do not use 13 = Termination
9 = do not use 21 = do not use RD– 15 5 = Logic GND 12 = SD– (RS422)
8 = do not use 12 SD–
20 = do not use 4 = do not use 11 = SD+ (RS422)
7 = Signal GND
C
7 5 3 = do not use 10 = RD– (RS422)
6 = do not use 19 = do not use GND
18 = do not use GND 4 2 = do not use 1 9 = RD+ (RS422)
5 = do not use 1 = Frame GND
4 = Signal GND 17 = do not use 1
3 = SD+ (RS422) 16 = SD– (RS422) shield
2 = RD+ (RS422) 1
1 = do not use
15 = RD– (RS422)
14 = do not use
Note: Use the above wiring diagram if you need to make your own cable. We recommend Belden 8103 shielded cable or equivalent.
D
®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20 6-27
Chapter 6: PLC Communications
Mitsubishi(cont’d): EA-MITSU-CBL-1
1 To PLC
8-Pin Port
Mitsubishi FX Series 8-pin MINI-DIN,
RS-422A (p/n EA-MITSU-CBL-1)
To C-more Touch
Panel PLC Port
15
15 = do not use
14 = do not use
13 = Termination
4 = SD– (RS-422) RD+ 2 11 SD+ 5 = Logic GND
4
12 = SD– (RS422)
3 4 5
5 = do not use 1 2
1 12
RD– SD– 4 = do not use 11 = SD+ (RS422)
6 = do not use
3 5 3 = do not use 10 = RD– (RS422)
7 = SD+ (RS-422) GND 2 = do not use 9 = RD+ (RS422)
8 = do not use 1 1
6 User Constructed
7 Mitsubishi Q02 / Q02H / Q06H / Q12H / Q25H Serial Driver
and QnA Serial Driver with Direct Connection to To C-more Touch
Panel PLC Port
To PLC the Serial Port on Q00 and Q01 CPU’s
6-Pin Port
8 RS-232C
9 1 = RXD (232C)
2 = TXD (232C)
Mini Din
6-pin Male Wiring Diagram
8 = do not use
15-pin
D-sub
(male) 15 = do not use
TXD 2 3 RXD 7 = do not use
3 = Logic GND 15 14 = do not use
10 4 = do not use
5 = do not use
6 = do not use
5
3
6
4
RXD
GND
1
3
2
5
TXD 6 = donot use
5 = Logic GND
4 = do not use
13 = do not use
12 = do not use
11 = do not use
1 2 1 3 = RXD (232C) 10 = do not use
11 shield
2 = TXD (232C) 1
1 = Frame GND
9 = do not use
Note: Use the above wiring diagram to make your own cable. We recommend using 22 AWG shielded cable.
12 User Constructed
13 To PLC
9-Pin Port
Mitsubishi Q / QnA Serial PLC
QJ71C24N
To C-more Touch
Panel PLC Port
RS-232C
14
Wiring Diagram
A 9-pin
CD 1
15-pin
DTR 4
D-sub D-sub
B 1 = CD 1
(female)
6 = DSR RS
DSR 6
7
8 = do not use (male)
7 = do not use
6 = do not use 15
15 = do not use
14 = do not use
13 = do not use
2 = RXD 7 = RS 8 5 = Logic GND 12 = do not use
C 3 = TXD CS
8 = CS 3 3 4 = do not use 11 = do not use
4 = DTR 9 = do not use TXD RXD
3 = RXD (232C) 10 = do not use
5 = Signal GND 9 2 2
RXD TXD 2 = TXD (232C) 9 = do not use
1
1 = Frame GND
D GND 5 5
shield 1
Note: Use the above wiring diagram if you need to make your own cable. We recommend using 22 AWG shielded cable.
6-28 ®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20
Chapter 6: PLC Communications
Omron:
EA-OMRON-CBL
To PLC
25-Pin Port
Omron Host Link (C200 Adapter, C500),
RS-232C (p/n EA-OMRON-CBL)
To C-more Touch
Panel PLC Port
1
2
25-pin Wiring Diagram
3
15-pin
D-sub D-sub
13 = do not use (male) 25 = do not use TXD 2 3 RXD 8 = do not use
12 = do not use (male) 15 = do not use
25 24 = do not use 3 2 7 = do not use 14 = do not use
11 = do not use 23 = do not use RXD TXD 15 13 = do not use
10 = do not use
9 = do not use
8 = do not use
22 = do not use GND 7
21 = do not use
20 = do not use RTS
4
5
6 = do not use
5 = Logic GND
4 = do not use
12 = do not use
11 = do not use
4
7 = Signal GND 3 = RXD (232C) 10 = do not use
19 = do not use CTS 5
6 = do not use
5 = CTS
4 = RTS
18 = do not use
17 = do not use shield 1
2 = TXD (232C) 1
1 = Frame GND
9 = do not use
5
3 = RXD 16 = do not use
6
2 = TXD 1 15 = do not use
1 = do not use 14 = do not use
Note: Use the above wiring diagram if you need to make your own cable. We recommend using 22 AWG shielded cable.
User Constructed 7
To PLC
9-Pin Port
Omron FINS (CQM1, CPM1, CPM2, C200, CJ1 & CS1)
RS-232C
To C-more Touch
Panel PLC Port 8
9-pin 15-pin
9
D-sub D-sub
1 = do not use
(male)
9
6 = do not use TXD 2
Wiring Diagram
3 RXD
8 = do not use (male)
7 = do not use
6 = do not use 15
15 = do not use
14 = do not use
13 = do not use
10
2 = TXD 7 = do not use 5 = Logic GND 12 = do not use
11
3 = RXD 3 2
8 = do not use RXD TXD 4 = do not use 11 = do not use
4 = RTS 9 = Signal GND SG 9 5 3 = RXD (232C) 10 = do not use
5 = CTS 1 2 = TXD (232C) 9 = do not use
RTS 4
1 = Frame GND 1
CTS 5
shield 1
12
Note: Use the above wiring diagram to make your own cable. We recommend using 22 AWG shielded cable.
13
User Constructed
To Peripheral Omron Host Link CQM1 using CQM1-CIF02 Peripheral Port Connecting Cable To C-more Touch
Panel PLC Port
14
Port Cable RS-232C
A
9-pin
D-sub
(male) Wiring Diagram 8 = do not use
7 = do not use
15-pin
D-sub
(male) 15 = do not use
14 = do not use
B
1 = do not use 9 6 = do not use
C
6 = do not use TXD 3 3 RXD 15 13 = do not use
2 = RXD 7 = do not use 5 = Logic GND 12 = do not use
3 = TXD 2 2
8 = do not use RXD TXD 4 = do not use 11 = do not use
4 = do not use 9 = do not use GND 5 5 3 = RXD (232C) 10 = do not use
5 = Signal GND 1
D
2 = TXD (232C) 9 = do not use
shield 1 1 = Frame GND 1
Note: Use the above wiring diagram to make your own cable. We recommend using 22 AWG shielded cable.
®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20 6-29
Chapter 6: PLC Communications
2
9-pin 15-pin
3 1 = do not use
D-sub
(male)
9
Wiring Diagram
7 = do not use
D-sub
8 = do not use (male) 15 = do not use
14 = do not use
6 = DSR TXD 3 3 RXD 6 = do not use 15 13 = do not use
4
2 = RXD 7 = RTS 5 = Logic GND
2 2 12 = do not use
3 = TXD 8 = CTS RXD TXD
4 = do not use 11 = do not use
4 = DTR 9 = do not use GND 5 5 3 = RXD (232C) 10 = do not use
5 = Signal GND 1 2 = TXD (232C) 1
4 9 = do not use
5 DTR
DSR 6
7
1 = Frame GND
RTS
6 CTS 8
shield 1
Note: Use the above wiring diagram to make your own cable. We recommend using 22 AWG shielded cable.
9 RS-232C
10 9-pin
D-sub
(female) Wiring Diagram
15-pin
D-sub
8 = do not use (male)
7 = do not use
15 = do not use
14 = do not use
1 = do not use 1 2 3 6 = do not use 13 = do not use
11 6 = do not use TXD RXD 15
2 = TXD 7 = do not use 5 = Logic GND 12 = do not use
3 = RXD 3 2
8 = do not use RXD TXD 4 = do not use 11 = do not use
4 = do not use 9 = do not use GND 5 5 3 = RXD (232C) 10 = do not use
5 = Signal GND 9 2 = TXD (232C)
12
9 = do not use
shield 1 1 = Frame GND 1
Note: Use the above wiring diagram to make your own cable. We recommend using 22 AWG shielded cable.
C 5 = Logic GND
6 = RTS
7 = CTS
RTS
CTS
6
7
5 = Logic GND
4 = do not use
3 = RXD (232C)
12 = do not use
11 = do not use
10 = do not use
8 = do not use 2 = TXD (232C) 1 9 = do not use
Note: Use the above wiring diagram to make your own cable. We recommend using 22 AWG shielded cable.
6-30 ®
EA-USER-M Hardware User Manual, 3rd Ed, Rev A, 06/20
Chapter 6: PLC Communications
Siemens:
User Constructed
To PLC
9-Pin Port
Siemens S7-200 CPU Port 0 or 1
RS-485A
To C-more Touch
Panel PLC Port 1
2
Wiring Diagram 13
9-pin Term. 15-pin
D-sub
(male)
9
RS-485
Signal B
3 9
11
RD+
SD+
D-sub
8 = do not use (male) 15 = do not use
7 = do not use 14 = do not use
3
1 = Logic Com 6 = +5 VDC 15
6 = do not use 13 = Termination
4
2 = Logic Com RS-485 8 10 RD–
7 = +24 VDC Signal A 5 = Logic GND 12 = SD– (RS485)
3 = RS485 Sig B 8 = RS485 Sig A 12
4 = do not use SD– 4 = do not use 11 = SD+ (RS485)
9 = do not use Logic 5 5 3 = do not use 10 = RD– (RS485)
5 = Logic Com 1 Common
5
2 = do not use 1 9 = RD+ (RS485)
shield 1 1 = Frame GND
Note: Use the above wiring diagram to make your own cable. We recommend AutomationDirect L19954 shielded cable or equivalent.
6
7
8
9
10
11
12
13
14
A
B
C
D
®