Wincc Flexible 2008 Runtime-Connection

The document provides instructions for connecting a PC running WinCC flexible Runtime to various controllers. The PC can connect to controllers via a communication processor or COM ports 1-4. The connections require specific hardware depending on the controller type, such as a CP 5511 module for a SIMATIC S7 via PROFIBUS DP connection. Common controller connections include SIMATIC S7 via PPI or MPI using a CP module or adapter. The PC must meet the manufacturer's requirements for electrical installation of communication hardware.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
57 views1 page

Wincc Flexible 2008 Runtime-Connection

The document provides instructions for connecting a PC running WinCC flexible Runtime to various controllers. The PC can connect to controllers via a communication processor or COM ports 1-4. The connections require specific hardware depending on the controller type, such as a CP 5511 module for a SIMATIC S7 via PROFIBUS DP connection. Common controller connections include SIMATIC S7 via PPI or MPI using a CP module or adapter. The PC must meet the manufacturer's requirements for electrical installation of communication hardware.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Setting up WinCC flexible Runtime

5.2 Electrical installation

5.2 Electrical installation

Connecting the PC to the controller


The PC is connected to the controller via a communciation processor or via the COM1 to
COM4 ports. Please refer to the hardware description from the manufacturer for the proper
electrical installation of your PC.
The table below shows the use of the interfaces:

Controller PC interface
SIMATIC S5 over AS511 COM1 to COM4 6)
requires an RS232/TTY adapter
SIMATIC S5 via PROFIBUS DP 1) via CP CP 5511, CP 5512, CP 5611
SIMATIC S7 via PPI via CP CP 5511, CP 5512, CP 5611, CP 5613, CP 5614
via PC/PPI adapter 2)
SIMATIC S7 via MPI via CP CP 5511, CP 5512, CP 5611, CP 5613, CP 5614
via PC/MPI adapter 3)
via PC adapter USB 3)
via Teleservice V5.1
SIMATIC S7 via PROFIBUS DP 4) via CP CP 5511, CP 5512, CP 5611, CP 5613, CP 5614
SIMATIC S7 -PROFINET via CP CP 1512, CP 1612, CP 1613
(Ethernet (TCP/IP)
SIMATIC 500/505 - NITP COM1 through COM4 (depending on arrangement)
SIMATIC 500/505 - PROFIBUS DP via CP CP 5511, CP 5512, CP 5611
SIMATIC HMI HTTP Protocol Ethernet 5)
OPC Ethernet network cards
Allen Bradley via DF, DH+, DH485 COM1 through COM4, depending on arrangement
Allen-Bradley Ethernet IP Ethernet
LG GLOFA-GM COM1 through COM4, depending on arrangement
Mitsubishi FX COM1 through COM4, depending on arrangement
Mitsubishi P4 COM1 through COM4, depending on arrangement
Modicon Modbus RTU COM1 through COM4, depending on arrangement
Modicon Modbus TCP/IP Ethernet
Omron COM1 through COM4, depending on arrangement
Telemecanique — not supported

1) WinCC flexible Runtime is passive node (DP slave)


2) Point-to-point connection with S7-200 only, no configuration transfer
3) Point-to-point connection with S7-300 or S7-400 only
4) WinCC flexible Runtime is active node
5) WinCC flexible Runtime must be installed on the devices
6)COM2 is blocked for the following devices:

WinCC flexible 2008 Runtime


User's Manual, 07/2008, 6AV6691-1BA01-3AB0 23