SDongleA-05 MODBUS TCP Guide
SDongleA-05 MODBUS TCP Guide
Issue 01
Date 2021-11-07
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees
or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Website: https://e.huawei.com
Preface
Purpose
This document describes how to enable/disable Modbus TCP and provides the
common-fault rectification methods, operations, and tool use guide.
Intended Audience
This document is intended for Modbus TCP personnel. Operator must:
● Be familiar with the product networking and related NEs' versions.
● Have device maintenance experience and be familiar with device operation
and maintenance.
Symbol Conventions
The symbols that may be found in this document are defined as follows.
Symbol Description
Change History
Issue Date Description
Contents
Preface........................................................................................................................................... ii
1 Before You Start....................................................................................................................... 1
1.1 Software of Device.................................................................................................................................................................. 1
1.2 Precautions................................................................................................................................................................................ 1
2 Networking Diagram.............................................................................................................. 2
3 Operations.................................................................................................................................3
3.1 Enable/Disable MODBUS TCP............................................................................................................................................. 3
3.1.1 Environment Setup.............................................................................................................................................................. 3
3.1.2 Procedure................................................................................................................................................................................ 3
3.1.3 Troubleshooting................................................................................................................................................................. 10
SDongleA-05 V100R001C00SPC124
SUN2000L V200R001C00SPC115
SUN2000MA V100R001C00SPC139
1.2 Precautions
Before enable/disable Modbus TCP, pay attention to the following:
● During the configuration, ensure that the Dongle is not powered off.
● After the configuration is complete, you do not need to perform the
configuration again after the device is powered off and then powered on.
● After the inverter is replaced, reconfigure the inverter.
● After the Dongle is replaced, you do not need to reconfigure the inverter.
2 Networking Diagram
NOTE
The Dongle and the customer's device must be in the same LAN. The access mode is not
limited (either network cable or Wi-Fi).
3 Operations
3.1.2 Procedure
Step 1 Downloading and Installing the App
Search for SUN2000 in the following app market, download the app installation
package (the version number must be 3.2.00.015 or later), and install the app by
following the instructions.
● Baidu Mobile Assistant (Android)
● Huawei AppGallery (Android)
After the installation is complete, the SUN2000 icon is displayed.
The WiFi name of the connected inverter is SUN2000-SN, which can be obtained from the
inverter label.
If you log in to the SUN2000 for the first time and do not change the WiFi
password, you can scan the WiFi QR code of the SUN2000 to connect to the WiFi
network.
Step 4 Select a user name and enter the password (select installer, and enter the correct
password, which is 00000a by default) to log in to the operation console.
Step 7 On the Communication configuration page, click Dongle parameter settings. The
Dongle parameter settings page is displayed.
NOTE
If the MODBUS TCP function is disabled, customer devices cannot access the network.
If the restriction function is enabled, you must configure a trustlist IP address (currently,
only one trustlist IP address is supported) so that only the client devices with the trustlist IP
address can access the network.
If unrestricted is enabled, all client devices on the same LAN can access the network, but
only one client device can access the network at a time.
----End
3.1.3 Troubleshooting
If Modbus TCP is not found in step 6, check whether the inverter version and app
version meet requirements.
If MODBUS TCP still cannot be used after the configuration is complete, check
whether the SDongle version meets the requirements.
.