Activated Carbon Adsorber (L1000V L8200V) BEKO

Download as pdf or txt
Download as pdf or txt
You are on page 1of 48

EN - english

Instructions for installation and operation

Activated-carbon adsorber without dust filter


CLEARPOINT® L 1000 – L 8200 V
08-068
Dear customer,
®
Thank you for deciding in favour of the CLEARPOINT V activated-carbon adsorber. Please read these
®
installation and operating instructions carefully before mounting and starting up the CLEARPOINT V
activated-carbon adsorber and follow our directions. Perfect functioning of the activated-carbon adsorber
can only be guaranteed when the provisions and notes stipulated here are strictly adhered to.

2 CLEARPOINT® L 205 – L295 V


Type plate CLEARPOINT® V activated-carbon adsorber

1 Type plate CLEARPOINT® V activated-carbon adsorber

Please enter the data from the type plate of the activated-carbon adsorber here!

CLEARPOINT® L 205 – L295 V 3


Contents

2 Contents
®
1 Type plate CLEARPOINT V activated-carbon adsorber ................................................................3
2 Contents ............................................................................................................................................4
3 General advice ..................................................................................................................................6
4 Safety instructions .............................................................................................................................7
4.1 Safety labelling ..................................................................................................................................7
4.1.1 Safety pictograms in accordance with DIN 4844 ..............................................................................7
4.1.2 Signal words in accordance with ANSI .............................................................................................8
4.2 General safety instructions................................................................................................................9
4.3 Special advice for plants under pressure in accordance with the 97/23/EC Pressure Equipment
Directive.......................................................................................................................................... 13
5 Residual risk ................................................................................................................................... 14
®
6 Field of application and proper use of the CLEARPOINT V activated-carbon adsorber.............. 14
7 Applied EU directives and harmonised standards ......................................................................... 15
®
8 General description of the CLEARPOINT V activated-carbon adsorber...................................... 16
9 Operating principle ......................................................................................................................... 17
10 Technical data ................................................................................................................................ 18
®
10.1 Technical data CLEARPOINT L 205-295 V ................................................................................. 18
10.2 Available options ............................................................................................................................ 20
10.3 Filter selection table ....................................................................................................................... 21
11 Description of the components....................................................................................................... 22
12 Transport and set-up ...................................................................................................................... 23
12.1 Safety during transport and set-up ................................................................................................. 23
12.2 Transport ........................................................................................................................................ 23
12.3 Set-up ............................................................................................................................................. 24
13 Installation ...................................................................................................................................... 25
13.1 Safety during the installation .......................................................................................................... 25
13.2 Minimum requirements................................................................................................................... 27
13.2.1 Filtration of the compressed air ...................................................................................................... 27
13.2.2 Water content of the compressed air ............................................................................................. 27
13.2.3 Inlet temperature of the compressed air ........................................................................................ 27
13.3 Installation examples ...................................................................................................................... 28
®
13.3.1 Installation diagram CLEARPOINT V with a refrigeration dryer ................................................... 28
®
13.3.2 Installation diagram CLEARPOINT V with an adsorption dryer ................................................... 29
13.4 Work steps during the installation .................................................................................................. 30
14 Start-up........................................................................................................................................... 31
14.1 Safety during the start-up ............................................................................................................... 31
14.2 Check prior to the start-up.............................................................................................................. 32
14.3 Initial start-up .................................................................................................................................. 33
14.4 Restart ............................................................................................................................................ 34
14.5 Removal from service..................................................................................................................... 34
15 Troubleshooting and fault elimination ............................................................................................ 35
15.1 Safety during troubleshooting and fault elimination ....................................................................... 35
15.2 Status and alarm indications .......................................................................................................... 37
16 Maintenance ................................................................................................................................... 39
16.1 Safety during maintenance............................................................................................................. 39

4 CLEARPOINT® L 205 – L295 V


Contents

16.2 Maintenance in general ...................................................................................................................41


®
16.3 Maintenance of the CLEARPOINT V activated-carbon adsorber .................................................41
16.3.1 Replacement of the activated carbon..............................................................................................42
16.4 Periodic inspections ........................................................................................................................44
17 Dismantling and disposal ................................................................................................................45
18 List of spare parts............................................................................................................................46
19 EC Declaration of Conformity..........................................................................................................46

CLEARPOINT® L 205 – L295 V 5


General advice

3 General advice

®
Prior to starting up the CLEARPOINT V activated carbon adsorber, it must be ensured that
the operating staff are instructed and skilled according to these instructions for installation and
operation with regard to the set-up, monitoring, operation and maintenance of the plant, as
well as to the safety measures to be observed.

The operating instructions must be accessible at all times at the place of application of the
device.

Non-observance of the installation and operating instructions involves risks for persons and
systems.

If you have any queries regarding these instructions, please contact BEKO TECHNOLOGIES
GMBH.

6 CLEARPOINT® L 205 – L295 V


Safety instructions

4 Safety instructions
4.1 Safety labelling
Safety instructions whose non-observance represents a threat to life and physical condition or can lead
to property damage are labelled in accordance with DIN 4844 and ANSI Z535.

4.1.1 Safety pictograms in accordance with DIN 4844

General danger symbol

Quickly escaping compressed air

Note

Observe operating instructions

Use eye protection

Wear light breathing protection

Use protective gloves

Wear ear protectors

CLEARPOINT® L 205 – L295 V 7


Safety instructions

4.1.2 Signal words in accordance with ANSI

Danger! Imminent hazard


Consequences of non-observance: serious injury or death

Warning! Potential hazard


Consequences of non-observance: possible serious injury or death

Caution! Imminent hazard


Consequences of non-observance: possibly injury or property damage

Notice! Potential hazard


Consequences of non-observance: possibly injury or property damage

Important! Additional advice, info, hints


Consequences of non-observance: disadvantages during operation and maintenance, no
danger

8 CLEARPOINT® L 205 – L295 V


Safety instructions

4.2 General safety instructions

Installation works must exclusively be carried out by authorised and qualified skilled
®
personnel. Prior to undertaking any measures on the CLEARPOINT V, the skilled personnel
shall read up on the device by carefully studying the operating instructions. The operator is
responsible for the adherence to these provisions. The respective directives in force apply to
the qualification and expertise of the skilled personnel.
For safe operation, the device must only be installed and operated in accordance with the
indications in the operating instructions. In addition, the national and operational statutory
provisions and safety regulations, as well as the accident prevention regulations required for
the respective case of application, need to be observed during employment. This applies
accordingly when accessories are used.

Danger!
Compressed air!
Risk of serious injury or death through contact with quickly or suddenly escaping
compressed air or through bursting and/or unsecured plant components.
All types of installation, maintenance and repair works must only be carried out when the
®
CLEARPOINT V is pressureless.
It is the operator’s duty to ensure that the connected pressure generator is secured against
exceeding of the maximum operating overpressure and the temperature limits at the
®
CLEARPOINT V.
The max. permissible operating parameters, such as the operating overpressure,
temperature and volume flow must not be exceeded. The max. permissible operating
parameters are specified on the type plate and in the technical data (see "Technical data"
section).
The operator must ensure through the installation of suitable safety devices that the safety-
relevant operating factors (pressure, temperature, flow) are not exceeded.
Pressure relief valves used need to be arranged in such a manner that endangering of
persons is excluded. Where required, observe the manufacturer's additional advice. Suitable
and permissible arming devices need to be provided in accordance with the local
regulations.
Never make structural modifications to the plant!
Use suitable tools and genuine spare parts and accessories only!
Only use fittings and connecting elements that are approved for this application. It is of vital
importance to observe the specifications of the respective manufacturer. Ensure that the
connections are installed according to good professional practice.
Only use pipes, valves and fittings which are suitable for the pressure and temperature
range. It is of vital importance to observe the specifications of the manufacturer.
Sudden impact through pressure build-up can cause damage and escape of compressed air.
Avoid a sudden pressure build-up by operating the valves slowly.
Check all pipe connections subsequent to the installation and retighten them if necessary!
The general safety and accident prevention regulations apply!
Prior to the start-up, a leak test needs to be carried out. This test shall only be effected by
correspondingly qualified skilled personnel in compliance with the safety regulations.

CLEARPOINT® L 205 – L295 V 9


Safety instructions

Caution!
Unauthorised intervention!
Unauthorised interventions may endanger persons and plants and lead to
malfunction.
Unauthorised interventions, modification and abuse of the pressure device are prohibited.
Operators of the devices must observe the local and national pressure equipment
regulations in the country of installation.

Danger!
High pressure!
Subsequent to the start-up, components of the plant are under pressure.
Risk of serious injury or death through contact with quickly or suddenly escaping
compressed air or through bursting and/or unsecured plant components.
Any installation, repair and maintenance works must only be carried out when the plant is
disconnected, pressureless and de-energised.

Warning!
Improper use and application!
Improper use and application can lead to injury and damage to plants.
The following use is considered improper and is therefore prohibited:
 Exceeding the max. permissible operating pressure
 Exceeding the max. permissible operating temperature
 Exceeding the max. permissible volume flow
 All individual cases of application which are described as improper

Caution!
Improper transport!
Improper transport can lead to injury and damage to plants.
®
The CLEARPOINT V must only be transported and installed by qualified and authorised
skilled personnel.
Only use suitable and technically unobjectionable lifting tools!
Only use lifting tools with a sufficient carrying capacity!
The respective national regulations and directives in force must be adhered to. Otherwise,
personal injuries may occur.

NOTE!
Damage through defective components!
®
Under no circumstances should you start up a damaged CLEARPOINT V. Defective
components can impair the operational reliability and cause further damage.

Caution!
Incorrect installation!
®
Incorrect installation of the CLEARPOINT V may endanger persons.
®
Ensure that the personnel in charge of the installation of the CLEARPOINT V are
sufficiently instructed and competent for this task.

10 CLEARPOINT® L 205 – L295 V


Safety instructions

Danger!
Incorrect start-up!
®
The incorrect start-up of the CLEARPOINT V may endanger persons.
®
Prior to starting up the CLEARPOINT V, it must be ensured that the operating staff are
instructed according to these instructions for installation and operation with regard to the set-
up, monitoring, operation and maintenance of the plant, as well as to the safety measures to
be observed.

CAUTION!
Operational reliability at risk!
®
Overloading the CLEARPOINT V can compromise the operational reliability!
Observe the permissible temperature range!
Do not exceed the permissible volume flow!

NOTE!
Operational reliability at risk!
Incorrect installation can compromise the operational reliability and affect service measures.
The clear diameter of the pipe joint must be at least as large as the mounting dimension of
®
the CLEARPOINT V.
It is strongly recommended to install a shut-off valve both upstream and downstream of the
®
CLEARPOINT V for the implementation of service measures.
To maintain the supply of compressed air during service failures, maintenance and repair
® ®
works on the CLEARPOINT V, the installation of a bypass line around the CLEARPOINT V
is advisable. This bypass line must have a shut-off valve.

Danger!
Mishandling!
®
Mishandling of the CLEARPOINT V may endanger persons.
®
Prior to starting up the CLEARPOINT V, it must be ensured that the operating staff are
instructed according to these instructions for installation and operation with regard to the set-
up, monitoring, operation and maintenance of the plant, as well as to the safety measures to
be observed.

Danger!
Incorrect maintenance!
®
The incorrect maintenance of the CLEARPOINT V may endanger persons.
Ensure that the personnel in charge of the operation, monitoring and maintenance of the
®
CLEARPOINT V are sufficiently instructed and competent for this task.

Caution!
Activated-carbon dust!
Eyes and respiration are endangered through quickly or suddenly escaping activated-

CLEARPOINT® L 205 – L295 V 11


Safety instructions

carbon dust.
Activated carbon can produce dust and wear debris!
Use eye protection!
During the start-up of the activated-carbon adsorber, compressed air might escape and
cause a very loud expansion noise. Wear silencing ear protectors.
Wear personal protective clothing!
Wear light breathing protection at strong dust development!

Caution!
Activated carbon produces dust and wear debris!
Endangering through dust explosion.
Use suitable tools and ex-protection-tested suction plants and accessories. Observe the
safety instructions.

12 CLEARPOINT® L 205 – L295 V


Safety instructions

4.3 Special advice for plants under pressure in accordance with the 97/23/EC
Pressure Equipment Directive
®
The CLEARPOINT V activated-carbon adsorber is a pressure device in the sense of the 97/23/EC
Pressure Equipment Directive. Therefore, the plant needs to be registered with the supervisory authority
in accordance with the local regulations, and requires the approval of the latter.

For the examination prior to the start-up and for periodic inspections, the national regulations need to be
observed, such as the industrial safety regulation in the Federal Republic of Germany. In countries
outside the EU, the respective regulations in force there need to be adhered to.

The proper use of pressure devices is the basic requirement for safe operation. As regards pressure
devices, the following needs to be observed:

®
The CLEARPOINT V must only be employed within the pressure and temperature range limits
indicated by the manufacturer on the type plate.
 No welding must be carried out on the pressure vessel of the device.

®
The CLEARPOINT V must neither be installed in insufficiently ventilated rooms nor near heat
sources or inflammable substances.

®
To avoid fractures resulting from material fatigue, the CLEARPOINT V should not be exposed
to vibrations during operation.
 The maximum operating pressure indicated by the manufacturer on the type plate must not be
exceeded. It is the operator's responsibility to install the appropriate safety and control devices.
®
Prior to the start-up of the CLEARPOINT V, the connected pressure generator (compressor
etc.) must be safeguarded against exceeding of the max. permissible operating pressure. The
integrated safeguard needs to be checked by an approved inspection agency.

®
The documents related to the CLEARPOINT V (manual, operating instructions, manufacturer's
declaration etc.) must be kept safe for future reference.

®
No objects whatsoever must be installed or placed on the CLEARPOINT V and the connecting
lines.
 Installation of the plant in frost-free places only.

WARNING!
Unauthorised intervention!
Unauthorised interventions may endanger persons and plants and lead to malfunction.
Unauthorised interventions, modification and abuse of the pressure devices are prohibited.
Operators of the devices must observe the local and national pressure equipment
regulations in the country of installation.

Warning!
High pressure!
®
Subsequent of the start-up of the CLEARPOINT V components of the plant are under
pressure. Serious injuries are possible.
®
Any installation, repair and maintenance works on the CLEARPOINT V must only be carried
out when the plant is pressureless.

CLEARPOINT® L 205 – L295 V 13


Residual risk

5 Residual risk
The plant offers state-of-the-art technology. However, certain residual risks remain.

 Risk through disregard of the safety instructions.

The safety instructions included in these operating instructions point to further residual risks. It is,
therefore, of vital importance to observe all safety instructions.

6 Field of application and proper use of the CLEARPOINT® V activated-carbon


adsorber
These operating instructions apply exclusively to the tank variants of the CLEARPOINTL 1000 V bis
L 8200 V activated-carbon adsorbers from BEKO TECHNOLOGIES GMBH and refer to the device type
without dust filter and internal tubing.
®
The CLEARPOINT V activated-carbon adsorber must only be applied under the conditions described in
this user manual, and only in connection with the components recommended or approved by the
manufacturer.
The field of application comprises the reduction of oil vapours and odorous substances from
compressed air or nitrogen. The system is intended for the use under industrial conditions inside
buildings.
Any other use is considered improper. The manufacturer shall not be liable for problems occurring as a
consequence of improper use. The operator alone is responsible for any hazard resulting from that.

Please check, prior to reading the operating instructions, whether or not these instructions
correspond to the device.
Read these installation and operating instructions carefully prior to any intervention regarding
®
the CLEARPOINT V.
The operating instructions must be accessible at all times at the place of application of the
device.
If you have any queries regarding these instructions, please contact BEKO
TECHNOLOGIES GMBH.

To ensure safe operation, the device must only be operated and maintained in accordance
with the indications in the operating instructions. In addition, the national and operational
statutory provisions and safety regulations, as well as the accident prevention regulations
required for the respective case of application, need to be observed during employment. This
applies accordingly when accessories are used.
Non-observance of the installation and operating instructions involves risks for persons and
systems.

Proper functioning and trouble-free operation of the activated-carbon adsorber is only ensured when the
transport, storage, set-up, installation, operation and maintenance are carried out in accordance with the
advice included in this user manual.
To handle the plant, the personnel must be trained to deal with devices of the compressed-air
technology and need to know the contents of this user manual as far as handling is concerned.
To start up and maintain the plant, the personnel must be familiar with the safety concepts of the
compressed-air technology. The personnel must be authorised and trained in such a manner that they
are capable of starting up and maintaining such facilities.
®
The proper employment and use of the CLEARPOINT V according to the directions requires the exact
compliance with the installation instructions, in particular in respect of:

 The place of installation, installation conditions


 The pressure and temperature of the inlet air

14 CLEARPOINT® L 205 – L295 V


Applied EU directives and harmonised standards

 The ambient temperature

The device is supplied as accepted in the factory. The operator only needs to establish the connections
with the compressed-air system, which is described in the following chapters.

WARNING!
Improper use!
The following is considered as improper use and is prohibited:
 Exceeding the max. permissible operating pressure
 Exceeding the max. permissible operating temperature
 Exceeding the max. permissible volume flow

®
Employment of the CLEARPOINT V in hazardous areas
 All individual cases of application which are not described as proper us

7 Applied EU directives and harmonised standards

Applied EU directives:

97/23/EC Pressure Equipment Directive

Harmonised standards applied:

EN 10216-2: Seamless steel tubes for pressure purposes. Technical delivery conditions -
Part 2: Non-alloy and alloy steel tubes with specified elevated temperature
properties
EN 10028-2: Flat products made of steels for pressure purposes - Part 2: Non-alloy and
alloy steels with specified elevated temperature properties
EN 10242: Threaded pipe fitting in malleable cast iron

AD-2000 bulletins

CLEARPOINT® L 205 – L295 V 15


General description of the CLEARPOINT® V activated-carbon adsorber

8 General description of the CLEARPOINT® V activated-carbon adsorber

®
The CLEARPOIINT L 1000 V bis L 8200 V activated-carbon adsorbers serve exclusively to separate
residual oil contents in the form of vapour or aerosol from compressed air and nitrogen.

The compressed air should be predried, and should not exceed a moisture content of 30% and a
temperature of +35°C. Exceeding these values will reduce the service life of the activated-carbon
adsorber. Therefore, the employment of a refrigeration or even an adsorption dryer is required upstream
of the activated-carbon adsorber.

With an appropriate dimensioning and when the operating parameters and load limits of the incoming
compressed air on which the dimensioning is based are adhered to, the oil content is drastically reduced
through the activated carbon contained in the adsorber. Besides the temperature, operating pressure
and volume flow, the exact life expectancy and dimensioning depends on the applied type of oil, the
compressor type and the humidity of the compressed air.

The following modifications of the operating conditions may lead to a reduction in the activated-carbon
adsorber’s service life:

 Increase of the volume flow


 Increase of the operating pressure
 Increase of the relative humidity of the compressed air
 Increase of the residual oil aerosol content at the inlet.

Therefore, you should benefit from the expertise of our special departments to design your activated-
carbon adsorber.

Depending on the actual quality of the compressed air in your supply network, a prefilter and at least a
refrigeration dryer is required for the incoming compressed air. The prefilter ensures that the oil aerosol
3
content of the incoming compressed air does not exceed a value of 0.01 mg/m . By treating the
compressed air with a refrigeration dryer, the maximum permissible humidity of the compressed air of
30% at the inlet into the adsorption dryer is guaranteed.

Not included in the scope of delivery:

 Prefilter
 Refrigeration dryer / adsorption dryer
 Afterfilter
 Internal tubing
 Oil check indicator

16 CLEARPOINT® L 205 – L295 V


Operating principle

9 Operating principle
The CLEARPOINT® V activated-carbon adsorber from BEKO TECHNOLOGIES GMBH functions
according to the principle of the accumulation of oil molecules on the surface and in the porous
structures of special activated carbon.

The activated carbon is in a container, through which the medium flows continuously top down.
The compressed air, from which the oil fractions need to be removed, enters the device through the
upper connection at the container.
Prior to that, the compressed air must have been filtered at least through a prefilter (residual oil aerosol
content 0.01 mg/m³ at +20°C) and should not exceed a relative humidity of 30% and a temperature of
+35°C. The service life of the activated-carbon adsorber will be reduced when these values are
exceeded. Therefore, the employment of a refrigeration dryer or even an adsorption dryer upstream of
the activated-carbon adsorber is advisable.

The compressed air flows through a compressed-air distributor and travels top down through the volume
filled with activated carbon. During this process, the activated carbon adsorbs the majority of the residual
oil aerosol contents and the oil vapour. Subsequently, the compressed air purified in this manner flows
through the lower compressed-air distributor to the outlet.
This process takes place without regeneration phases. The activated carbon is thus gradually saturated
with oil molecules and therefore needs to be replaced when the predefined service life has expired.

Activated carbon is able to reliably adsorb a wide range of non-polar hydrocarbons; there are, however,
restrictions regarding the adsorption capacity as far as polar hydrocarbons are concerned (e.g.
benzene). It must also be taken into account that abruptly changing operating conditions (pressure,
volume flow) may lead to desorption of the already intercalated hydrocarbons.
.

It is explicitly recommended to provide a shut-off valve both upstream and downstream of the activated-
carbon adsorber and to install a bypass around the activated-carbon adsorber. These components are
not included in the scope of delivery.

Fließbild
CLEARPOINT® L 1000 –L 8200 V

In order to reduce pressure loss, a fill of activated alumina was filled into the bottom of the container.

CLEARPOINT® L 205 – L295 V 17


Technical data

10 Technical data
®
10.1 Technical data CLEARPOINT L 205-295 V

®
Name CLEARPOINT L 1000 – L 8200 V
BEKO TECHNOLOGIES GMBH
Manufacturer Germany,
41468 Neuss, Im Taubental 7
Type Activated-carbon adsorber
Compressed air
Saturated up to 30%
Medium Free from water or condensate
Free from aggressive or corrosive
components
Minimum ambient temperature +5°C
Maximum ambient air temperature +50°C
Maximum air volume flow at the inlet See table
Minimum compressed-air inlet temperature +2°C
Maximum compressed-air inlet temperature +50°C
Recommended compressed-air inlet temperature +35°C*
Recommended residual humidity of the
< 30%*
compressed air at the inlet
Maximum permissible operating overpressure L
11 bar(g)
1000-8200 V
Recommended operating pressure 7 bar(g)
Residual oil content at the outlet max. 0.003 mg/m³
Adsorbent Activated carbon type 1
Service life at nominal performance data and
Approx. 10,000 operating hours
reference conditions
Compressed-air connection See table
Height x width x depth approx. See table
Weight approx. See table
Category acc. to PED 97/23/EC – fluid group 2 See table

Design data pressure vessel


Design pressure L 1000-8200 V 11 bar(g)
Design temperature -10 / +120°C
In accordance with PED 97/23/EC
Design and construction
and AD-2000

* The service life of the activated-carbon adsorber is reduced when this value is exceeded

18 CLEARPOINT® L 205 – L295 V


Technical data

Abmessungen
CLEARPOINT® L 1000 – L 8200 V

Volume Activated Category


Type Connection A** B** C** Weight
flow* carbon PED 97/23/EC

[m³/h] DN [mm] [mm] [mm] [kg] [kg] Fluid gr. 2

L 1000 V 1000 65 2300 650 630 100 305 IV


L 1250 V 1250 65 2300 700 680 130 355 IV
L 1550 V 1550 65 2270 750 755 165 420 IV
L 1700 V 1700 80 2335 750 805 180 500 IV
L 2000 V 2000 80 2360 850 855 210 600 IV
L 2300 V 2300 100 2480 850 905 245 670 IV
L 2600 V 2600 100 2500 1000 955 280 750 IV
L 2900 V 2900 100 2520 1000 1005 310 820 IV
L 3400 V 3400 100 2540 1000 1055 360 920 IV
L 4200 V 4200 150 2810 1100 1030 440 1120 IV
L 5000 V 5000 150 2870 1250 1130 530 1370 IV
L 6000 V 6000 150 2930 1250 1225 635 1630 IV
L 7000 V 7000 150 2970 1450 1345 740 1930 IV
L 8200 V 8200 150 3010 1450 1445 870 2220 IV

* Maximum volume flow at the inlet acc. to ISO 7183, related to +35°C and 7 bar(g)
** ±30 mm

CLEARPOINT® L 205 – L295 V 19


Technical data

10.2 Available options

Prefilter It is recommended to use a BEKO ultrafilter with an automatic


condensate drain. This prefilter ensures that the oil aerosol content of
the incoming air does not exceed a value of 0.01 mg/m³.
For details, please refer to the following filter selection table.

Afterfilter Downstream of each activated-carbon adsorber, an afterfilter


(minimum requirement 1 µm) must be installed that retains dusts and
particles from the activated carbon that develop due to the way the
system operates.

It is recommended to use a BEKO dust filter in an oil and grease-


free version.
For details, please refer to the following filter selection table.

Compressed-air dryer For the safe functioning of the CLEARPOINT® V, the compressed air
must not exceed a relative humidity of 30% at the inlet into the
activated-carbon adsorber. The service life of the activated-carbon
adsorber will be reduced when these values are exceeded. Therefore,
the employment of a refrigeration or even an adsorption dryer is
required upstream of the activated-carbon adsorber.
Please contact our specialist departments to select a suitable
compressed-air dryer.

Oil check indicator For the rough assessment of the compressed-air quality, an oil check
indicator can be used. The oil check indicator can be installed on the
head of the CLEARPOINT dust filter (you will find the adapter and oil
check indicator, as well as replacement test tubes, in our price list).

®
METPOINT OCV residual For the continuous qualitative assessment of the compressed-air
®
oil measuring device quality, the use of our METPOINT OCV residual oil measuring device
®
is advisable. By means of a measuring section, the METPOINT OCV
can be installed in the pipework downstream of the afterfilter, and will
then show the residual oil vapour content ONLINE.

Service determination Our service department will be happy to submit you a corresponding
residual oil content offer for the cyclic qualitative assessment of the compressed-air
quality.

20 CLEARPOINT® L 205 – L295 V


Technical data

10.3 Filter selection table

Option dust filter


Option prefilter
Filter + filter elements purified without oil
Model
Ultrafilter Dust filter outlet
(0.01 µm / 0.01 mg/m³ *) Filter element (1 µm / 0.1 mg/m³ *) Filter element

L 1000 V M023SWT 23S M025RFWMX-OF 25F-OF


L 1250 V M025SWT 25S M027RFWMX-OF 27F-OF
L 1550 V M025SWT 25S M027RFWMX-OF 27F-OF
L 1700 V M027SWT 27S M032RFWMX-OF 32F-OF
L 2000 V M030SWT 30S M032RFWMX-OF 32F-OF
L 2300 V L100SWT 88S L100RFWM 88F
L 2600 V L100SWT 88S L100 RFWM 88F
L 2900 V L100SWT 88S L100 RFWM 88F
L 3400 V L102SWT 88S L102 RFWM 88F
L 4200 V L102SWT 88S L102 RFWM 88F
L 5000 V L150 SWT 88S L150RFWM 88F
L 6000 V L150 SWT 88S L150 RFWM 88F
L 7000 V L156 SWT 88S L156 RFWM 88F
L 8200 V L156 SWT 88S L156 RFWM 88F

*at 20°C and 1 bar absolute according to ISO 8573

CLEARPOINT® L 205 – L295 V 21


Description of the components

11 Description of the components

1 Compressed-air INLET

2 Filler neck for activated carbon

3 Container for the activated-carbon filling

4 Manometer pressure vessel

5 Compressed-air - OUTLET

6 Draining nozzle for activated carbon

22 CLEARPOINT® L 205 – L295 V


Transport and set-up

12 Transport and set-up


12.1 Safety during transport and set-up

IMPORTANT!
Danger through improper transport!
®
The CLEARPOINT V must only be transported and installed by qualified and authorised
skilled personnel.
Only use suitable and technically sound lifting tools!
Only use lifting tools with a sufficient carrying capacity!
The respective national regulations and directives in force must be adhered to. Otherwise,
personal injuries may occur.

IMPORTANT!
Danger through damaged components!
®
Under no circumstances should you start up a damaged CLEARPOINT V. Defective
components can impair the operational reliability and cause further damage.

12.2 Transport
®
The CLEARPOINT V activated-carbon adsorber was thoroughly tested and packed prior to leaving the
factory. It was in a perfect condition when handed over to the forwarding agent.
®
Despite all due care, transport damage cannot be excluded. Therefore, check the CLEARPOINT V for
possible transport damage subsequent to transport and removal of the packaging material. The
forwarding agent and BEKO TECHNOLOGIES or the BEKO TECHNOLOGIES agency must be informed
immediately about any kind of damage. If no evident damage to the packaging or the plant was
ascertained but hidden defects are detected at a later moment in time, the forwarding agent must
immediately be informed so as to allow him to assess and document the damage.
In the event that the plant is damaged, it is imperative to contact the manufacturer to know whether or
not the system may be started up.

Please observe the following points regarding the transport:

 Provide suitable lifting tools for the transport.


 Persons in charge of the transport must have the corresponding qualification.
 With the lifting tools, the activated-carbon adsorber must only be lifted at the intended points
(transport pallet, frame, eyebolts on the top of the container).
 Observe the weight of the activated-carbon adsorber and the maximum permitted load of the
lifting tools and means of transport used.
 National regulations regarding accident prevention must be adhered to.

CLEARPOINT® L 205 – L295 V 23


Transport and set-up

12.3 Set-up
Observe the transport and lifting instructions on the packaging.
Provide suitable lifting tools for the transport and set-up.
®
Secure the CLEARPOINT V against shifting on the fork-lift truck.
®
Move the CLEARPOINT V to the place of installation.
®
The function and service life of the CLEARPOINT V depends on the conditions at the place of
installation. This place must meet the following requirements:
 The device is installed within a building.
 The device must not be operated in explosive or fire-endangered atmospheres, in an
environment with aggressive chemicals, superheated steam or strong contamination, or in a very
hot environment.

®
The CLEARPOINT V must be protected against moisture.
 The ambient temperature must not exceed/undercut the indications in the "Technical data"
section.

®
Choose an even, solid and vibration-free set-up area. The weight of the CLEARPOINT V must
be taken into account when choosing the area.

®
No vibrations must be transferred to the CLEARPOINT V. If necessary, install the activated-
carbon adsorber on vibration dampers.
 The pipework must be free from mechanical stress (otherwise risk of bursting).
 It must be ensured that vibrations from other plant components cannot be transferred. This also
and particularly concerns the pulsation of the compressed air as otherwise, the activated carbon
may be destroyed.

®
Set up the CLEARPOINT V in such a manner that the plant is easily accessible from the sides.
For checks of the pressure vessels, maintenance and repair measures, sufficient free space
®
must be available on all sides (at least 1.5 m) around the CLEARPOINT V.
 Install the activated-carbon adsorber in such a manner that the front panel with the manometer is
well accessible.
 The activated-carbon adsorber must be fixed on the floor area by means of the bores in the
frames or feet. In particular as far as devices without a frame construction are concerned, the
tank needs to be secured against tilting at the intended place of installation. In the further course
of the installation, the pipes and dust filters (not included in the scope of delivery) must be fixed
separately, if required.
 Ensure sufficient ventilation and heat removal.

®
Keep a safe distance from transport routes when setting up the CLEARPOINT V.
 Equip the plant with a suitable collision guard.

In the event of doubt, we recommend obtaining expert advice regarding the place of installation.
®
Remove the packaging of the CLEARPOINT V.
®
Move the CLEARPOINT V to the place of installation.
®
Position the CLEARPOINT V at the desired place and adjust the plant accordingly.

24 CLEARPOINT® L 205 – L295 V


Installation

13 Installation
13.1 Safety during the installation

Installation works must exclusively be carried out by authorised and qualified skilled
®
personnel. Prior to undertaking any measures on the CLEARPOINT V, the skilled personnel
shall read up on the device by carefully studying the operating instructions. The operator is
responsible for the adherence to these provisions. The respective directives in force apply to
the qualification and expertise of the skilled personnel.
For safe operation, the device must only be installed and operated in accordance with the
indications in the operating instructions. In addition, the national and operational statutory
provisions and safety regulations, as well as the accident prevention regulations required for
the respective case of application, need to be observed during employment. This applies
accordingly when accessories are used.

DANGER!
Compressed air!
Durch Kontakt mit schnell oder schlagartig entweichender Druckluft oder durch berstende
Anlagenteile besteht die Gefahr schwerer Personenschäden oder Tod.
Jegliche Installations-, Wartungs- und Reparaturarbeiten dürfen nur am drucklosen
®
CLEARPOINT V durchgeführt werden.
Es ist die Pflicht des Betreibers sicherzustellen, dass der angeschlossene Druckerzeuger
gegen Überschreiten des maximalen Betriebsüberdruckes und der Temperaturgrenzen am
®
CLEARPOINT V abgesichert ist.
The max. permissible operating parameters, such as the operating overpressure,
temperature and volume flow must not be exceeded. The max. permissible operating
parameters are specified on the type plate and in the technical data (see "Technical data"
section).
The operator must ensure through the installation of suitable safety devices that the safety-
relevant operating factors (pressure, temperature, flow) are not exceeded.
Pressure relief valves used need to be arranged in such a manner that endangering of
persons is excluded. Where required, observe the manufacturer's additional advice. Suitable
and permissible safety arming devices need to be provided in accordance with the local
regulations.
Niemals bauliche Veränderungen an der Anlage durchführen!
Nur geeignetes Werkzeug und Original Ersatz- und Zubehörteile verwenden!
Nur Armaturen und Verbindungselemente verwenden, die für diese Anwendung zugelassen
sind. Beachten Sie unbedingt die Angaben der jeweiligen Hersteller. Achten Sie auf
fachgerechte Montage der Anschlüsse.
Es sind nur Rohrleitungen, Ventile und Fittings einzusetzen, die für den Druck- und
Temperaturbereich geeignet sind. Beachten Sie unbedingt die Angaben des Herstellers.
Schlagartige Belastung durch Druckaufbau kann Beschädigungen und Austritt von Druckluft
verursachen. Vermeiden Sie schlagartigen Druckaufbau durch langsame Betätigung der
Ventile.
Prüfen Sie nach der Installation sämtliche Rohrverbindungen und ziehen Sie diese ggf.
nach!
Es gelten die allgemeinen Sicherheitsbestimmungen und Unfall-Verhütungs-Vorschriften!
Vor der Inbetriebnahme muss eine Dichtheitsprüfung durchgeführt werden. Durchführung
nur von entsprechend qualifiziertem Fachpersonal unter Beachtung der Sicherheits-
vorschriften..

CLEARPOINT® L 205 – L295 V 25


Installation

Danger!
Incorrect installation!
®
Incorrect installation of the CLEARPOINT V involves the risk of personal injury.
®
Ensure that the personnel in charge of the installation of the CLEARPOINT V are
sufficiently instructed and competent for this task.

NOTE!
Installation works!
Installation works at the compressed-air system must only be carried out by skilled
1
personnel authorised by the operator.

CAUTION!
Danger through damaged components!
®
Under no circumstances should you start up a damaged CLEARPOINT V. Defective
components can impair the operational reliability and cause further damage.

NOTE!
Operational reliability at risk!
Incorrect installation can compromise the operational reliability and affect service measures.
The clear diameter of the pipe joint must be at least as large as the mounting dimension of
®
the CLEARPOINT V.
It is strongly recommended to install a shut-off valve both upstream and downstream of the
®
CLEARPOINT V for the implementation of service measures.
To maintain the supply of compressed air during service failures, maintenance and repair
® ®
works on the CLEARPOINT V, the installation of a bypass line around the CLEARPOINT
V is advisable. This bypass line must have a shut-off valve.

1
Authorised skilled personnel are persons who are authorised by the operator, with experience and technical
training, who are well-grounded in the respective provisions and laws and capable of carrying out the required works
and of identifying and avoiding any risks during the machine transport, installation, operation and maintenance.

26 CLEARPOINT® L 205 – L295 V


Installation

13.2 Minimum requirements


13.2.1 Filtration of the compressed air

Prefilter: Super-fine filter (S) with condensate drain


max. residual content oil aerosols 0.01 mg/m³ at 20°C

Afterfilter: Dust filter (F) with manual drain


Particle classification 1 µm

13.2.2 Water content of the compressed air

Max. permissible residual humidity: < 30%

13.2.3 Inlet temperature of the compressed air

Recommended inlet temperature: + 35°C

Non-observance of the indicated minimum requirements regarding the installation and


permissible operating parameters can lead to drastic reduction of the service life of the
®
CLEARPOINT V activated-carbon adsorber.

CLEARPOINT® L 205 – L295 V 27


Installation

13.3 Installation examples


®
13.3.1 Installation diagram CLEARPOINT V with a refrigeration dryer

1 Universal filter (G) with BEKOMAT


2 Refrigeration dryer
3 Super-fine filter (S) with BEKOMAT
4 Activated-carbon adsorber
5 Dust filter (F) with manual drain
®
6 Sensor unit METPOINT OCV
® Oil- and grease-
7 Evaluation unit with user interface METPOINT OCV
free zone
H1/H2 Shut-off valves of the measuring section
H3 Shut-off valve of the bypass
H4 Vent valve of the measuring section

®
The depicted installation shows the minimum requirement regarding the installation of a CLEARPOINT
V activated-carbon adsorber. Other types of installation are possible (provided that they meet the defined
operating conditions).
®
For service measures, it is recommended to install a bypass around the CLEARPOINT V. This applies
generally to all components to be serviced in compressed-air systems. Please observe that this bypass
must also be free from oil and grease!

28 CLEARPOINT® L 205 – L295 V


Installation
®
13.3.2 Installation diagram CLEARPOINT V with an adsorption dryer

1 Super-fine filter (S) with BEKOMAT


2 Adsorption dryer
3 Dust filter (F) with manual drain
4 Activated-carbon adsorber
5 Dust filter (F) with manual drain
®
6 Sensor unit METPOINT OCV
® Oil-and grease-free
7 Evaluation unit with user interface METPOINT OCV
zone
H1/H2 Shut-off valves of the measuring section
H3 Shut-off valve of the bypass
H4 Vent valve of the measuring section

®
The depicted installation shows another installation possibility of the CLEARPOINT V activated-carbon
adsorber that meets the minimum requirements. Other types of installation are possible (provided that
they meet the defined operating conditions).
®
For service measures, it is recommended to install a bypass around the CLEARPOINT V. This applies
generally to all components to be serviced in compressed-air systems. Please observe that this bypass
must also be free from oil and grease!

CLEARPOINT® L 205 – L295 V 29


Installation

13.4 Work steps during the installation


It is strongly recommended to install a shut-off valve both upstream and downstream of the
®
CLEARPOINT V.
To maintain the supply of compressed air during service failures, maintenance and repair works on the
® ®
CLEARPOINT V, the installation of a bypass line around the CLEARPOINT V is advisable. This
bypass line must have a shut-off valve.
Installation example with prefilter, afterfilter, shut-off valves and bypass:

®
To install the CLEARPOINT V, proceed as follows:

®
Ensure that the conditions of use of the CLEARPOINT V are met and that the operation limits
are not exceeded.

®
Ensure that the system is pressureless prior to integrating the CLEARPOINT V into the
compressed-air system.
 Prior to installation, it must be ensured that all possible contaminations are removed from the
compressed-air system.
 Connect the following connections with your supply system or with your plant:

 Compressed-air inlet (1)


 Compressed-air outlet (2)

Carry out a leak test of the connections prior to the start-up.

30 CLEARPOINT® L 205 – L295 V


Start-up

14 Start-up
14.1 Safety during the start-up

It is imperative to observe all specifications and notes in these installation and operating
instructions
Non-observance of the installation and operating instructions involves risks for persons and
systems.
If you have any queries regarding these instructions, please contact BEKO
TECHNOLOGIES GMBH.

Warning!
Incorrect start-up!
®
The incorrect start-up of the CLEARPOINT V involves the risk of personal injury.
®
Prior to starting up the CLEARPOINT V, it must be ensured that the operating staff are
instructed according to these instructions for installation and operation with regard to the set-
up, monitoring, operation and maintenance of the plant, as well as to the safety measures to
be observed.

DANGER!
Compressed air!
Risk of serious injury or death through contact with quickly or suddenly escaping
compressed air or through bursting plant components.
Maintenance, inspection and installation works must exclusively be carried out by authorised
®
and qualified skilled personnel. Prior to undertaking any measures on the CLEARPOINT V
the skilled personnel shall read up on the device by carefully studying the operating
instructions. The operator is responsible for the adherence to these provisions. The
respective directives in force apply to the qualification and expertise of the skilled personnel.
It is the operator’s duty to ensure that the connected pressure generator is secured against
exceeding of the maximum operating overpressure and the temperature limits at the
®
CLEARPOINT V.
Do not exceed the max. permissible operating overpressure. The max. permissible operating
overpressure is specified on the type plate and in the technical data (see "Technical data"
section).
Sudden impact through pressure build-up can cause damage and escape of compressed air.
Avoid a sudden pressure build-up by operating the valves slowly.
The general safety and accident prevention regulations apply!

CAUTION!
Operational reliability at risk!
®
Overloading the CLEARPOINT V can compromise the operational reliability!
Observe the permissible temperature range!
Do not exceed the permissible volume flow!

Caution!
Activated-carbon dust!
Eyes and respiration are endangered through quickly or suddenly escaping activated-
carbon dust.
Activated carbon can produce dust and wear debris!
Use eye protection!
During the start-up of the activated-carbon adsorber, compressed air might escape and

CLEARPOINT® L 205 – L295 V 31


Start-up

cause a very loud expansion noise. Wear silencing ear protectors.


Wear personal protective clothing!
Wear light breathing protection at strong dust development!

14.2 Check prior to the start-up


As regards the check prior to the start-up, the country-specific provisions need to be observed.

The plant contains pressure equipment of different categories according to the 97/23/EC
Pressure Equipment Directive. For this reason it is necessary to register the entire plant with
the relevant authority in accordance with the local provisions and to have it approved.
In countries outside the EU, the respective regulations in force there need to be adhered to.

32 CLEARPOINT® L 205 – L295 V


Start-up

14.3 Initial start-up

Please fill in the data from the type plate of the activated-carbon adsorber into the
table on page 3!

Work steps:

®
Ensure that the conditions of use of the CLEARPOINT V are met and that the operation limits
are not exceeded.
 Check the operating data of the plant and compare these with the permissible operating data
from the "Technical data" section. Should you ascertain deviations, adjust the operating
parameters according to the specifications.
 Ensure that all installation steps were carried out properly.
 Check whether or not the activated-carbon adsorber is completely tubed. If not, carry out proper
installation.
 Check whether or not the shut-off valves upstream of the inlet and downstream of the outlet of
the activated-carbon adsorber are closed. If not, close both shut-off valves.
 Set the compressed-air system under system pressure upstream of the shut-off valve on the
entering side of the activated-carbon adsorber. If required, start the compressor.
 Open the shut-off valve upstream of the activated-carbon adsorber slowly. The activated-carbon
adsorber is set under operating pressure.

Filling of the activated-carbon adsorber with compressed air during the start-up must
be implemented as slowly as possible. Under no circumstances must the flow rates
which correspond to those of the nominal performance data be exceeded.
Recommended amount of compressed air during the filling of the activated-carbon
adsorber:
Pressure build-up approx. 1 bar/min (or 1% of the nominal performance)
This is particularly important during the initial start-up / subsequent to maintenance
measures. Flow rates which are too high cause high pressure difference and impulse-
like strong abrasive wear on the activated carbon which can also overwhelm the
downstream dust filter.

 Check all pipe connections for tightness.


 Open the shut-off valve downstream of the outlet filter slowly and set the entire compressed-air
system under pressure.

Filling of the downstream tank/pipe network must be implemented as slowly as possible and
must, under no circumstances, exceed the flow rates of the nominal performance data. The
operating pressure at the activated-carbon adsorber must be maintained (see manometer).
This is particularly important during the initial start-up/subsequent to maintenance measures.
Flow rates which are too high cause impulse-like strong abrasive wear on the activated
carbon which can also overwhelm the downstream dust filter.

CLEARPOINT® L 205 – L295 V 33


Start-up
®
Prior to delivery the activated carbon that is contained in the CLEARPOINT V is dried in the factory. If
the activated-carbon adsorber is not installed immediately after having been delivered, and if it is
installed downstream of an adsorption dryer, it may be necessary to allow dry compressed air to flow
through the activated-carbon adsorber for approximately four to six hours to remove the residual
moisture from the activated carbon.
®
If the activated-carbon adsorber is equipped with a METPOINT OCV, the initial start-up should be
®
implemented without METPOINT OCV. To prevent the risk of contaminations through dust, the
®
METPOINT OCV should only be installed after a trial run of several hours (for the installation of the
probe, the plant section again needs to be unpressurised).
®
Subsequent to the successful start-up, no other works are required. The CLEARPOINT V is now ready
to operate. In the event that unexpected failures occur during the running operation, please inform the
service technician who is responsible for you.

14.4 Restart
®
If the CLEARPOINT V is restarted after a longer down time, proceed as during the initial start-up.
®
Check, above all after completed maintenance or repair measures, whether the CLEARPOINT V is
completely tubed. If not, carry out proper installation.

14.5 Removal from service


For safety reasons, short-term removal from service should always be implemented together with the
compressor.

For the removal from service during maintenance or repair measures, please proceed as follows:

 Unpressurise the plant prior to any maintenance or repair measures!


 Open the bypass line (not included in the scope of delivery).
 Close the shut-off valves (not included in the scope of delivery) upstream and downstream of the
activated-carbon adsorber.
 Unpressurise the activated-carbon adsorber.

Stagnation pressure may occur in pipe sections or in the container due to plugging. It
is imperative to observe the manometer at the container during the pressure
reduction! Ensure that there is no stagnation pressure in pipe sections or in the
container. This is particularly possible if the compressed-air distributor or the filter
element of the afterfilter (not included in the scope of delivery) are blocked as a result
of a large amount of wear debris.

34 CLEARPOINT® L 205 – L295 V


Troubleshooting and fault elimination

15 Troubleshooting and fault elimination


15.1 Safety during troubleshooting and fault elimination
Works regarding the troubleshooting and fault elimination must exclusively be carried out by
authorised and qualified skilled personnel. Prior to undertaking any measures on the
®
CLEARPOINT V, the skilled personnel shall read up on the device by carefully studying the
operating instructions. The operator is responsible for the adherence to these provisions.
The respective directives in force apply to the qualification and expertise of the skilled
personnel.
For safe operation, the device must only be operated and maintained in accordance with the
indications in the operating instructions. In addition, the national and operational statutory
provisions and safety regulations, as well as the accident prevention regulations required for
the respective case of application, need to be observed during employment. This applies
accordingly when accessories are used.

Danger!
Incorrect fault elimination!
®
The incorrect fault elimination at the CLEARPOINT V involves the risk of personal injury.
Ensure that the personnel in charge of the operation, supervision and maintenance of the
®
CLEARPOINT V are sufficiently instructed and competent for this task.

NOTE!
Troubleshooting and fault elimination!
Operations, system performance tests, installation, setting and maintenance measures at the
2
compressed-air system must only be carried out by skilled personnel authorised by the
operator.

2
Authorised skilled personnel are persons who are authorised by the operator, with experience and technical
training, who are well-grounded in the respective provisions and laws and capable of carrying out the required works
and of identifying and avoiding any risks during the machine transport, installation, operation and maintenance.

CLEARPOINT® L 205 – L295 V 35


Troubleshooting and fault elimination

DANGER!
Compressed air!
Risk of serious injury or death through contact with quickly or suddenly escaping
compressed air or through bursting plant components.
All types of installation, maintenance and repair works must only be carried out when the
®
CLEARPOINT V is pressureless.
The max. permissible operating overpressure must not be exceeded. The max. permissible
operating overpressure is specified on the type plate and in the technical data (see
"Technical data" section).
Never make structural modifications to the plant!
Use suitable tools and genuine spare parts and accessories only!
Only use pipes, valves and fittings which are suitable for the pressure and temperature
range. It is of vital importance to observe the specifications of the manufacturer.
Check all pipe connections subsequent to maintenance or repair measures and retighten
them if necessary!
Prior to the restart, a leak test needs to be carried out. This test shall only be effected by
correspondingly qualified skilled personnel in compliance with the safety regulations.

36 CLEARPOINT® L 205 – L295 V


Troubleshooting and fault elimination

15.2 Status and alarm indications

Residual oil content too high

Possible cause of failure Fault elimination

Inlet volume flow too high  Reduce the inlet volume flow

Operating pressure too low  Increase the operating pressure

 Reduce the compressed-air temperature


Compressed-air temperature at the inlet too high at the inlet
 Install a precooler, if required

Inlet filter elements exhausted


 Replace the inlet filter elements
Pressure difference too high

Use of oil-contaminated filters or filter elements  Use of BEKO filters and filter elements in
downstream of the activated-carbon adsorber an oil- and grease-free version

Oil-contaminated circuit sections between the


 Clean the pipesection or install a new
activated-carbon adsorber and the measuring
pipesection
point

 Check the functioning of the condensate


Condensate drainage upstream of the activated-
drain (at the inlet filter), repair or replace
carbon adsorber does not work
it, if required

Max. absorption capacity of the activated carbon


 Replace the activated carbon
reached

CLEARPOINT® L 205 – L295 V 37


Troubleshooting and fault elimination

Container pressure too low / Operating pressure in the system too low

Possible cause of failure Fault elimination

 Check the pressure drop via the inlet filter


Pressure difference of the inlet filter is too high  Replace the filter element, if required

The compressed-air system upstream of the  Check the compressed-air system


activated-carbon adsorber is pressureless upstream of the activated-carbon adsorber
 Eliminate any faults

 Replace the dust filter element


Larger amounts of wear debris in the system:  Replace the activated carbon
clogged compressed-air distributor or filter  Clean the compressed-air distributor
elements
 Verify the operating conditions (pulsation,
volume flow)

NOTE!
In the event of malfunctions which are not listed here or which cannot be eliminated, please
contact BEKO TECHNOLOGIES GMBH.

38 CLEARPOINT® L 205 – L295 V


Maintenance

16 Maintenance
16.1 Safety during maintenance

Maintenance, inspection and installation works must exclusively be carried out by authorised
®
and qualified skilled personnel. Prior to undertaking any measures on the CLEARPOINT V
the skilled personnel shall read up on the device by carefully studying the operating
instructions. The operator is responsible for the adherence to these provisions. The
respective directives in force apply to the qualification and expertise of the skilled personnel.
For safe operation, the device must only be operated and maintained in accordance with the
indications in the operating instructions. In addition, the national and operational statutory
provisions and safety regulations, as well as the accident prevention regulations required for
the respective case of application, need to be observed during employment. This applies
accordingly when accessories are used.

Danger!
Incorrect maintenance!
®
Incorrect maintenance of the CLEARPOINT V involves the risk of personal injury.
Ensure that the personnel in charge of the operation, supervision and repair of the
®
CLEARPOINT V are sufficiently instructed and competent for this task.

NOTE!
Maintenance works!
Operation, system performance checks, installation, setting and maintenance measures at
3
the compressed-air system must only be carried out by skilled personnel authorised by the
operator.

3
Authorised skilled personnel are persons who are authorised by the operator, with experience and technical
training, who are well-grounded in the respective provisions and laws and capable of carrying out the required works
and of identifying and avoiding any risks during the machine transport, installation, operation and maintenance.

CLEARPOINT® L 205 – L295 V 39


Maintenance

DANGER!
Compressed air!
Risk of serious injury or death through contact with quickly or suddenly escaping
compressed air or through bursting plant components.
All types of installation, maintenance and repair works must only be carried out when the
®
CLEARPOINT V is pressureless.
Do not exceed the max. permissible operating overpressure. The max. permissible operating
overpressure is specified on the type plate and in the technical data (see "Technical data"
section.
Never make structural modifications to the plant!
Use suitable tools and genuine spare parts and accessories only!
Only use pipes, valves and fittings that are suitable for the pressure and temperature range.
It is of vital importance to observe the specifications of the manufacturer.
Check all pipe connections subsequent to maintenance or repair measures and retighten
them if necessary!
Prior to the restart, a leak test needs to be carried out. This test shall only be effected by
correspondingly qualified skilled personnel in compliance with the safety regulations.

Caution!
Activated-carbon dust!
Eyes and respiration are endangered through quickly or suddenly escaping activated-
carbon dust.
Activated carbon can produce dust and wear debris!
Use eye protection!
During the start-up of the activated-carbon adsorber, compressed air might escape and
cause a very loud expansion noise. Wear silencing ear protectors.
Wear personal protective clothing!
Wear light breathing protection at strong dust development!

Caution!
Activated carbon produces dust and wear debris!
Endangering through dust explosion.
Use suitable tools and ex-protection-tested suction plants and accessories. Observe the
safety instructions.

40 CLEARPOINT® L 205 – L295 V


Maintenance

16.2 Maintenance in general


The plant must be checked at regular intervals in accordance with the applicable national regulations. In
this respect, the following points need to be observed:
 In order to ensure high operational and performance reliability, regular maintenance measures
are required.
 Watch for abnormalities and possible malfunctions during the running operation.
 Deficiencies must immediately be reported to the responsible units/persons.
 For emergency cases, there must be the possibility to cut off the plant section.

16.3 Maintenance of the CLEARPOINT® V activated-carbon adsorber

Action daily weekly annually*

Check the exterior of the plant for contaminations,


x
damages and corrosion
Record the current operating parameters and compare
x
them with the indications under "Technical data"

Check the manometer x

Check all pipe connections and threaded connections and


x
retighten them if necessary

Check the activated-carbon adsorber for leaks x

Verify the result of the oil adsorption (e.g. by means of a


® x
METPOINT OCV or a laboratory analysis)

Replace the activated carbon x

* or every 10,000 operating hours

CLEARPOINT® L 205 – L295 V 41


Maintenance

16.3.1 Replacement of the activated carbon


Depending on the operating conditions, the activated carbon has a service lifetime of approximately
10,000 operating hours. Afterwards, the adsorption capacity of the activated carbon is exhausted.

As a matter of principle, replace the complete contents of the activated-carbon filling.

The activated carbon must be replaced by a correspondingly trained and authorised specialist company.
Please request the BEKO service.
The employed activated carbon is not subject to any labelling obligation in accordance with the
Ordinance on Hazardous Substances. However, the usual precautions regarding the handling of
chemicals need to be taken.
In the event of fire, there are no restrictions regarding the applicable fire-extinguishing agents. It is
recommended to use CO2, powder or a directed spray of water; use a directed spray of water or alcohol-
resistant foam in the event of larger fires. Special personal protective equipment for firefighting is not
required.
Spilled activated carbon should be removed, avoiding dust to the largest possible extent.

To replace the activated carbon, please carry out the following work steps:

1. Remove the plant from service. For this purpose, follow the directions in the "Removal from service"
section.

®
2. Place a suitable vessel under the CLEARPOINT V activated-carbon adsorber and open the
draining nozzle (6) at the bottom.

42 CLEARPOINT® L 205 – L295 V


Maintenance

3. Allow the used, activated carbon to flow into the receiver. Ensure sufficient dust extraction.
Subsequent to the full drainage of the container, reclose this nozzle with the seal and blind plug.

According to the industrial safety regulations, the selection of a suitable suction system
is incumbent on the operator of the plant. In this respect, the relevant regulations of
explosion protection need to be taken into account, as the dusts contained in the
activated carbon may induce an explosive atmosphere, depending on the amount and
consistency.
The suction system should be checked with regard to the dust explosion hazard and
approved for these areas (minimum requirement zone 22). Please use conductive
accessories only.
Where flammable vapours or gases exist, an additional approval for the gas explosion
protection is required. Where contamination through toxic, harmful, mutagenic or
mutation-promoting components is anticipated, suitable filters must additionally be
provided.

4. Fill the container with activated alumina until you reach pos. A. Subsequently fill the container with
activated carbon until you reach the lower edge of the upper circular weld (pos. B). Only use the
original activated carbon from BEKO TECHNOLOGIES GMBH. Use a commercially available funnel
for filling.

CLEARPOINT® L 205 – L295 V 43


Maintenance

5. Mount the fill plug with a seal at the filler neck (2) of the container.

6. Check the connections for tightness. In this respect, follow the directions in the "Initial start-up"
section.

16.4 Periodic inspections


®
The pressure vessel of the CLEARPOINT V activated-carbon adsorber must be checked at regular
intervals by a technical expert or an authorised expert. The determination of the time limits regarding
periodic inspections is incumbent on the operator and, depending on the classification into the pressure
device category in accordance with the Pressure Equipment Directive, must be carried out by a certified
inspection agency.

44 CLEARPOINT® L 205 – L295 V


Dismantling and disposal

17 Dismantling and disposal


®
When dismantling the CLEARPOINT V, all parts and operating media related to the plant must be
disposed of separately.

®
The CLEARPOINT V is supplied ready to operate with the following operating materials:

Type Amount [kg]


® Operating material
CLEARPOINT V undried
L 1000 V Activated carbon type 2 / activated alumina 100 / 22
L 1250 V Activated carbon type 2 / activated alumina 130 / 27
L 1550 V Activated carbon type 2 / activated alumina 165 / 35
L 1700 V Activated carbon type 2 / activated alumina 180 / 40
L 2000 V Activated carbon type 2 / activated alumina 210 / 60
L 2300 V Activated carbon type 2 / activated alumina 245 / 70
L 2600 V Activated carbon type 2 / activated alumina 280 / 80
L 2900 V Activated carbon type 2 / activated alumina 310 / 90
L 3400 V Activated carbon type 2 / activated alumina 360 / 100
L 4200 V Activated carbon type 2 / activated alumina 440 / 130
L 5000 V Activated carbon type 2 / activated alumina 530 / 170
L 6000 V Activated carbon type 2 / activated alumina 635 / 200
L 7000 V Activated carbon type 2 / activated alumina 740 / 240
L 8200 V Activated carbon type 2 / activated alumina 870 / 290

Adsorbent!
The activated carbon used must be supplied to proper disposal. The local regulations need
to be observed.

Waste code according to the EWC

Waste code Waste designation


06 13 02 Used activated carbon

CLEARPOINT® L 205 – L295 V 45


List of spare parts

18 List of spare parts

In a dry condition, activated carbon is significantly more absorptive regarding hydrocarbons and other air
pollutants as in a wet condition. Therefore, the design point for the dimensioning of activated-carbon
adsorbers lies at a relative humidity of 30% at BEKO Technologies.
In order to make activated carbon work well, new activated carbon or activated carbon used for the filling
of the activated-carbon adsorber during maintenance works should be in a very dry condition.
In order to have, as soon as possible, a fully absorptive activated-carbon adsorber again during
maintenance works, BEKO Technologies offers the supply of predried activated carbon.
We recommend checking the compressed-air distributors, which are installed between the upper and
lower girth flanges and the pipe, every 10,000 operating hours for damage and contamination and to
replace them, if required.

Type Order no. Order no. Order no.


CLEARPOINT V Activated carbon Activated carbon Compressed-air
predried undried distributor
2x each
L 1000 V 4024567 4024610 4019831
L 1250 V 4024568 4024611 4019831
L 1550 V 4024569 4024612 4019831
L 1700 V 4024570 4024613 4019831
L 2000 V 4024571 4024614 4019810
L 2300 V 4024572 4024615 4019810
L 2600 V 4024573 4024616 4019810
L 2900 V 4024574 4024617 4019810
L 3400 V 4024575 4024618 4019810
L 4200 V 4024576 4024619 4019813
L 5000 V 4024577 4024620 4019813
L 6000 V 4024578 4024621 4019813
L 7000 V 4024579 4024622 4019813
L 8200 V 4024580 4024623 4019813
Ersatzröhrchen für
Bestellnummer 4005900 für alle Größen
Ölprüfindikator

19 EC Declaration of Conformity
The Declaration of Conformity is enclosed with the vessel documents that were sent to you under
separate cover to the billing address.

46 CLEARPOINT® L 205 – L295 V


EC Declaration of Conformity

CLEARPOINT® L 205 – L295 V 47


Headquarter : 中华人民共和国 / China France
BEKO TECHNOLOGIES (Shanghai) Co. BEKO TECHNOLOGIES S.à.r.l.
Deutschland / Germany Ltd. Zone Industrielle
BEKO TECHNOLOGIES GMBH Rm.606 Tomson Commercial Building 1 Rue des Frères Rémy
Im Taubental 7 710 Dongfang Rd. F- 57200 Sarreguemines
D-41468 Neuss Pudong Shanghai China Tél. +33 387 283 800
Tel.: +49 (0)2131 988 0 P.C. 200122 [email protected]
[email protected] Tel. +86 21 508 158 85
[email protected]

India Italia / Italy 日本 / Japan


BEKO COMPRESSED AIR BEKO TECHNOLOGIES S.r.l BEKO TECHNOLOGIES K.K
TECHNOLOGIES Pvt. Ltd. Via Peano 86/88 KEIHIN THINK 8 Floor
Plot No.43/1, CIEEP, Gandhi Nagar, I - 10040 Leinì (TO) 1-1 Minamiwatarida-machi
Balanagar, Hyderabad - 500 037, INDIA Tel. +39 011 4500 576 Kawasaki-ku, Kawasaki-shi
Tel +91 40 23080275 [email protected] JP-210-0855
[email protected]
Tel. +81 44 328 76 01
[email protected]

Benelux Polska / Poland Scandinavia


BEKO TECHNOLOGIES B.V. BEKO TECHNOLOGIES Sp. z o.o. www.beko-technologies.com
Veenen 12 ul. Chłapowskiego 47
NL - 4703 RB Roosendaal PL-02-787 Warszawa
Tel. +31 165 320 300 Tel +48 (0)22 855 30 95
[email protected] [email protected]

España / Spain South East Asia 臺灣 / Taiwan


BEKO Tecnológica España S.L. BEKO TECHNOLOGIES S.E.Asia BEKO TECHNOLOGIES Co.,Ltd
Polígono Industrial "Armenteres" (Thailand) Ltd.
16F.-5, No.79, Sec. 1,
C./Primer de Maig, no.6 75/323 Romklao Road
Xintai 5th Rd., Xizhi Dist.,
E-08980 Sant Feliu de Llobregat Sansab, Minburi
New Taipei City 221,
Tel. +34 93 632 76 68 Bangkok 10510
Taiwan (R.O.C.)
[email protected] Thailand
Tel. +886 2 8698 3998
Tel. +66 (0) 2-918-2477
[email protected]
[email protected]

Česká Republika / Czech Republic United Kingdom USA


BEKO TECHNOLOGIES s.r.o. BEKO TECHNOLOGIES LTD. BEKO TECHNOLOGIES CORP.
Mlýnská 1392 2 West Court 900 Great SW Parkway
CZ - 562 01 Usti nad Orlici Buntsford Park Road US - Atlanta, GA 30336
Tel. +420 465 52 12 51 Bromsgrove Tel. +1 (404) 924-6900
[email protected] GB-Worcestershire B60 3DX [email protected]
Tel. +44 1527 575 778
[email protected]

Translation of the original operating instructions.


Original operating instructions in German.
Subject to technical changes / errors excepted.
CLEARPOINT Aktivkohleadsorber o.F. L1000-8200 V manual_en_2013_04

You might also like