2021 EMC Fundamentals Guide
2021 EMC Fundamentals Guide
2021 EMC
FUNDAMENTALS
GUIDE
rohde-schwarz.com/emc-testing
INTERFERENCE TECHNOLOGY
TABLE OF CONTENTS
2021 EMC Supplier Guide 5
What is EMC? 10
GHERY PETTIT
Pettit EMC Consulting LLC
REFERENCE SECTION 32
Common Commercial EMC Standards 32
LinkedIn Groups 42
Index of Advertisers 48
ANNIVERSARY
When EMI protection is important, top manufacturers choose Spira EMI gaskets. Spira gaskets are
well known for solving EMI shielding problems that no other gasket can solve, and are perfect for
both military and commercial applications. Gaskets are designed to be highly reliable, and built to
last the life of the system. Salt fog, high humidity and RoHS versions are available. Choose Spira
gaskets to pass your shielding tests the first time.
EMI & Environmental Spira-Shield. All Spira Shielded Honeycomb Groundbreaking new book
Connector-Seal Gaskets. gaskets utilize our unique Air-Vent and Fan Filters. on EMI Shielding Theory.
Superior EMI and environ- patented spiral design High and reliable shielded A new, more accurate and
mental protection for flange- which yields EMI shielding filters at competitive prices efficient way for engineers to
mounted connectors in front quality up to 165 dB with providing over 80dB of understand electromagnetic
or back mount configurations. exceptionally long life. shielding at 1GHz. shielding theory and practice.
Introduction
In this section, we provide a quick guide to some of the top suppliers in each EMC category–test equipment,
components, materials, services, and more. To find a product that meets your needs for applications, frequen-
cies, standards requirements, etc., please search these individual supplier websites for the latest information and
availability. If you have trouble finding a particular product or solution, email [email protected] for further
supplier contacts.
TESTING LABORATORIES
CABLES & CONNECTORS
SHIELDED ROOMS
TEST EQUIPMENT
EMI RECEIVERS
CERTIFICATION
CONSULTANTS
COMPONENTS
WORKSHOPS
AMPLIFIERS
SHIELDING
ANTENNAS
TESTING
MEDIA
COMPANY WEBSITE
Aaronia AG www.aaronia.com X X X X
Advanced Test Equipment
www.atecorp.com X X X X X X X X X X X X
Rentals (ATEC)
AH Systems, Inc. www.ahsystems.com X X X X X X
Altair- US www.altair.com X X
American Certification Body
https://acbcert.com/ X X X X X X
A Inc.
Ametek- CTS Compliance Test
www.ametek-cts.com X X X X X
Solutions
Anritsu Company www.anritsu.com X X X X X
API Technologies www.apitech.com X X
AR RF/Microwave
www.arworld.us X X X X X X X X
Instrumentation
Astrodyne www.astrodyneTDI.com X
B Beehive Electronics www.beehive-electronics.com X
Captor Corporation (EMC Div.) www.captorcorp.com X
Coilcraft www.coilcraft.com X X
C
CPI- Communications &
www.cpii.com/emc X
Power Industries (USA)
Dassault System Simulia
www.3ds.com/ X
Corp
TESTING LABORATORIES
CABLES & CONNECTORS
SHIELDED ROOMS
TEST EQUIPMENT
EMI RECEIVERS
CERTIFICATION
CONSULTANTS
COMPONENTS
WORKSHOPS
AMPLIFIERS
SHIELDING
ANTENNAS
TESTING
MEDIA
COMPANY WEBSITE
Prana www.prana-rd.com X
Pulse Power &
https://ppmtest.com/ X
Measurement Ltd
TESTING LABORATORIES
CABLES & CONNECTORS
SHIELDED ROOMS
TEST EQUIPMENT
EMI RECEIVERS
CERTIFICATION
CONSULTANTS
COMPONENTS
WORKSHOPS
AMPLIFIERS
SHIELDING
ANTENNAS
TESTING
MEDIA
COMPANY WEBSITE
Radiometrics www.radiomet.com X
R&B Laboratory, Inc. www.rblaboratory.com X
Retlif Testing
www.retlif.com X X X
Laboratories
RIGOL Technologies www.rigolna.com X X X X X
R
R&K Company Limited www.rk-microwave.com X X
Rohde & Schwarz GmbH
www.rohde-schwarz.com/de X X X X X X X
& Co. KG
Rohde & Schwarz USA,
www.rohde-schwarz-usa.com X X X X X X X
Inc.
Schaffner EMC, Inc. www.schaffner.com X X X X
Schurter, Inc. www.schurter.com X X
Schwarzbeck Mess-
www.schwarzbeck.com X
Elektronik
S Select Fabricators www.select-fabricators.com X X
Siglent Technologies www.siglentna.com X
Signal Hound www.signalhound.com X X X X
Solar Electronics www.solar-emc.com X
Spira Mfg. Corp. www.spira-emi.com X
TDK www.tdk.com X X X X
Tektronix www.tek.com X
Teledyne LeCroy www.teledynelecroy.com X
TESEQ Inc. www.teseq.com X
Test Equity www.testequity.com/leasing/ X X X X
Thurlby Thandar (AIM-
www.aimtti.com X X
TTi)
T
www.toyotechus.com/emc-
Toyotech (Toyo)
electromagnetic-compatibility/
X X X X
TPI www.rf-consultant.com X
Transient Specialists www.transientspecialists.com X
www.trsrentelco.com/
TRSRenTelCo categories/spectrum- X X X X X X X
analyzers/emc-test-equipment
Vectawave Technology www.vectawave.com X
V V Technical Textiles /
www.vtechtextiles.com X
Shieldex US
www.schaffner.com
WHAT IS EMC?
Ghery S. Pettit
[email protected]
Introduction
This article will serve as an introduction to the topic. It is aimed at the people who have been told by their man-
agement, “You are now my EMC person. Go figure out what it is and how we must deal with it!” It will not be an all
encompassing treatment of the subject, but it will provide the reader with a start and some ideas of where to go
for more information.
WHAT IS EMC? in value, but they will not exceed it. The example shown
is for a 50% duty cycle signal with a frequency of 500
EMC stands for electromagnetic compatibility. You will MHz, a rise and fall time of .03 x 10-9 seconds, a pulse
see some people refer to EMC/EMI, but this is partially width of .97 x 10-9 seconds and an amplitude of 3.3 volts.
redundant. EMI (electromagnetic interference) is just a
part of EMC. The two major parts of EMC are EMI and
EMS (electromagnetic susceptibility) as it is called in the
aerospace and military world and electromagnetic immu-
nity (as it is called in the commercial world). Susceptibility
and immunity are pretty much the same thing, just called
by different terms. Susceptibility is a measure of how
a device reacts to various items in the electromagnetic
environment and immunity is simply a demonstration of
its failure to react to certain levels of these phenomena.
Emissions are regulated in the commercial world in var-
ious ways and immunity for commercial products is reg-
ulated in certain countries and not at all in many others.
In the aerospace and military world, a common standard Figure 1: Frequencies resulting from a 500 MHz trapezoidal waveform
for emissions and susceptibility is MIL-STD-461G. Var-
ious tests and levels are called out for various services There are a couple of key things to note in Figure 1, in-
and products. In the commercial world, it depends on cluding that the computed harmonics do not always rise
what product is being discussed, but for information tech- to the envelope in Figure 2, but never exceed it. If you
nology equipment (ITE), broadcast receivers, and multi- were to look at the signal (ideal) in both the time and fre-
media equipment, CISPR 32 provides limits for emissions quency domains, it will look something like the following:
and CISPR 35 provides tests and test levels for immunity.
In the U.S., the FCC in Part 15 of its rules provides limits
for emissions and does not mandate immunity for digital
devices. In fact, the rules specifically state that a Part 15
device must accept any interference received. Countries
that mandate immunity, on the other hand, require that
products not suffer inference when tested to the levels
called out in the applicable standards.
signer, but it definitely is RF and will certainly radiate and Finally, there is a path for the interfering emission to
cause interference to licensed services. travel from the source to the victim. This may be a direct
radiation path or a conducted path. It may fall under the
Why is this preceding information important? It gives the control of the operator of the source, it may fall under
EMC engineer a tool for computing the frequencies that the control of the operator of the victim, or a combination
may come from the product, at least as harmonics of of both.
intentionally generated digital signals. It also gives a tool
for computing the amplitudes of these signals. The next HOW DO I FIX AN EMC PROBLEM?
step, at least for computing the radiated or conducted To quote a retired professor (Todd Hubing), “It depends.”
emissions, will be to compute the coupling factor or fac- What is the problem? Did your product fail an EMC test?
tors, as a function of frequency. Or, if the measurements Is it causing harmful interference to another device or
have already been performed, then troubleshooting to service? Fix your product. This is especially important if
bring them into compliance may be the next thing on the you only control the source (in the case of emissions) or
agenda. the victim (in the case of immunity testing). If you control
both the source and victim, you may be able to alter the
Another means by which RF energy can be created by path and leave the source and/or victim alone.
a product is due to transmission lines that are not prop-
erly terminated. The frequency of these emissions will Let’s assume that your product is failing an emissions
not necessarily be harmonically related to the frequency test. This is not the best time to find out that you have an
of the signal being sent down the transmission line, but, EMC problem as marketing probably wants to ship the
will instead, be related to the propagation velocity of the product soon and you are being called the roadblock to
wave down the transmission line and its length. This ter- shipping and are therefore the bad guy. Never mind that
mination may be designed into the product at either end you have been telling the project team for a year that
of the transmission line and each has its advantages and there are areas they need to address, and they have
disadvantages. Troubleshooting these emissions can refused to make changes you’ve recommended. This
take more detective work. is where a prime requirement to being an EMC engi-
neer comes in—you must have a thick skin and stick to
There are a number of ways that RF energy created by your guns. No data showing compliance, no shipment
a product through its normal operation can generate and of product. Get to know the project lawyers well in ad-
radiate unintentional emissions that can cause interfer- vance, they likely will be on your side. You’ll spend long
ence or simply failure to pass emissions limits. This paper hours in the lab finding and fixing the problem(s). Oh,
will not go into detail on each as this would be way be- and your fixes must be manufacturable and, ideally,
yond the scope of a single paper, but things to consider cheap (or even free). Sometimes these are, and some-
are current loops, exit points from PWBs for cables, by- times they aren’t. Sometimes a product that passed in
passing (all filters are not created equal and installation the lab last week or last month will have had a change
methods are critical), component layout, trace routing, made by a vendor as it was easier for them to make
chassis and packaging design, and “grounding”. Notice the part and your company’s specification wasn’t tight
that I put quotation marks around grounding. Grounding enough to prevent the change. Can you find this prob-
in the EMC sense does not mean connection to earth lem quickly and tell the program team how to fix it? Oh,
ground. Ask yourself how this would be possible for a and there are some problems that you will find repeated-
satellite in geosynchronous orbit around the earth. Ob- ly over a career as new designers come and go, creat-
viously, it isn’t, and satellites typically have to meet far ing job security for EMC engineers. So, from a personal
more stringent EMC requirements than your computer on point of view, these easy to find and fix problems aren’t
your desk. all bad. At least not after you’ve found and fixed them a
few times over the years. It you are new to the game it
WHAT IS A MODEL FOR INTERFERENCE? will take a bit longer.
There are three basic components in the interference
model that must be considered. IMMUNITY
I haven’t discussed immunity as a separate issue much
There is a source. This may be a board, a complete de- in this paper. The good news (at least on the commercial
vice, or natural event. It generates the emission that is side of the discussion) is that immunity isn’t typically a
causing the problem. major issue for designers and EMC engineers. Prior to
immunity requirements being published for the first time
There is a victim. This is the device (component, board, about 30 years ago one major manufacturer only had in-
or full product) that suffers interference that causes what- ternal specifications for electrostatic discharge and pow-
ever malfunction is being noted. This may be an unin- er line surges. Nothing else in their experience showed
tended operation or a failure to operate on the part of the itself to be an issue. Some of the commercial immunity
device suffering as a victim. requirements are so low that the EMC engineer can tell
the project designers 6 months in advance that he will • Introduction to Electromagnetic Compatibility, 2nd
run the test only because it is required, but not to wor- Edition, Clayton R. Paul, John Wiley & Sons, 2006
ry as the product will pass. Or the company may have
internal requirements for significantly higher test levels, Clayton has passed away, much to the sorrow of
in which case more attention must be paid to the test those of us who knew him, but if I was limited to a
phenomena. ESD and surge testing, however, do not single book on EMC, this is the one I would have. Not
fall in the camp of serious concern. If a designer lives a simple, easy to read, treatment on the subject, but
and works in an area where humidity levels are typically complete and comprehensive. I highly recommend
high, he probably doesn’t have much experience or wor- this book.
ry about ESD failures. If, however, he lives and works in
an area like the front range of Colorado or Washington • PCB Design for Real-World EMI Control, Bruce Ar-
D.C. where humidity levels can be very low, he likely will chambeault and James Drewniak, Kluwer Academic
be a firm believer in ESD. Likewise for electrical surge, if Publishers, 2002/2004
the designer lives in an area where lightning storms are
common surge is an issue. If not, no worries. However, The title says it all. It is limited to PCBs, but it is a
the product must be sold and used in areas where these great treatment on the subject, by two gentlemen
are common problems. who are well respected in the EMC world. Bruce is
a past president of the IEEE EMC Society and has
Then there are the immunity or susceptibility matters that been around the block more than once.
must be considered to avoid problems like the U.S.S.
Forrestal in the late 1960s. Susceptibility can be a serious There are plenty more books and papers that you can
matter. Three V/m may be adequate for some commer- read and learn from. This is just a start, but for someone
cial environments, but the flight deck of an aircraft carrier new to the EMC world this will be a great start.
is not one of those environments. Do a Google search
and look for the video and discussion of what went wrong Have fun and feel free to ask questions when you have
on the Forrestal to see what I mean. some. I don’t say “if” because after 44 years I still have
many.
CONCLUSION
EMC is a matter deserving of serious consideration. It
may only be a matter of whether a product can ship on
time, or it may be a matter of life and death. Learn about
it, ask questions of people who are considered experts
in the subject (I’ll give you my definition of “expert” some
time), and read books and articles on the subject. Also,
attend events where you can learn more about EMC by
listening to papers, talking with vendors, and networking
with “your fellow wizards”. You’ll find in many of those
places that EMC folks (engineers and technicians) are
EMC professionals first and employees of X, Y, or Z com-
pany second. They won’t disclose company secrets, but
they will help you fight a common enemy—EMC issues.
Listed below are a few places where you can learn more
about EMC.
Kenneth Wyatt
Wyatt Technical Services
[email protected]
BASIC EMI CONCEPTS second. The actual physical mechanism of near light
speed propagation is due to a “kink” in the E-field, which
Understanding EMC is all about two important concepts: propagates along the molecules of copper. Refer to Ref-
(1) all currents flow in loops and (2) high frequency sig- erences 1, 2, and 3 for further details.
nals are propagated as electromagnetic waves in trans-
mission lines and the field energy travels through the di-
electric. The two concepts are related because they are
intertwined together. Digital signals create the propagat-
ing field, which induces the convection current to flow in
the copper traces/planes.
Where some board designs go wrong is when high dV/ Most of us were taught the “circuit theory” point of view
dt return signals, such as those from low frequency DC- and it is important when we visualize how return currents
DC switch mode converters or high di/dt return signals want to flow back to the source. However, we also need
get comingled with I/O circuit return currents or sensitive to consider the fact that the energy of the signal is not
analog return currents. We’ll discuss PC board design only the current flow, but an electromagnetic wave front
in the next article. Just be aware of the importance of moving through the dielectric, or a “field theory” point of
designing defined signal and power supply return paths. view. Keeping these two concepts in mind just reinforc-
That’s why the use of solid return planes under high fre- es the importance of designing transmission lines (power
quency signals and then segregating digital, power, and and signal traces with return path directly adjacent), rath-
analog circuitry (keeping them separate) on your board is er than just simple circuit trace routing.
so important.
It is very important to note that all power distribution
HOW SIGNALS MOVE networks (PDNs) and high frequency signal traces are
At frequencies greater than DC, digital signals start to transmission lines and the energy is transferred as elec-
propagate as electromagnetic tromagnetic waves at about half the speed of light in nor-
mal FR4-type board dielectrics. We’ll show what happens
waves in transmission lines. As shown in Figure 1, a high when the return path or return plane is interrupted by a
frequency signal propagates along a microstrip transmis- gap in the next article. More on PDN design may be found
sion line (circuit trace over return plane, for example), in Reference 4, 5, and 6.
and the wave front induces a conduction current in the
copper trace and back along the return plane. Of course, DIFFERENTIAL MODE VERSUS COMMON
this conduction current cannot flow through the PC board MODE CURRENTS
dielectric, but the charge at the wave front repels a like Referring to Figure 2, the differential mode current (in
charge on the return plane, which “appears” as if current blue) is the digital signal itself (in this case, shown in a
is flowing. This is the same principle for capacitors and ribbon cable). As described above, the conduction cur-
Maxwell called this effect “displacement current”. rent and associated return current flow simultaneously as
the signal wave front moves along the transmission line
The signal’s wave front travels at some fraction of the formed by the microstrip and return plane.
speed of light, as determined by the dielectric constant
of the material, while the conduction current is comprised The common mode current (in red) is a little more complex
of a high density of free electrons moving at about 1 cm/ in that it may be generated in a number of ways. In the fig-
ure, the impedance of the return plane results in small volt- SUMMARY
age drops due to multiple simultaneous switching noise To summarize product design for EMI compliance, a prop-
(SSN) by the ICs. These voltage drops induce common erly designed PC board with adjacent return planes to
noise currents to flow all over the return (or reference) all signals and PDNs, properly bonded I/O cable shields,
plane and hence, couple into the various signal traces. well bonded shielded enclosures with minimal slots or
gaps, and common mode filtering on all I/O and power
cables for unshielded products is generally required for
best EMI performance. Paying attention to these factors
early in the design greatly reduces the risk of EMC and
EMI compliance failures.
REFERENCES
1. Bogatin, Signal Integrity - Simplified, 3rd edition,
Prentice-Hall, 2018.
2. Morrison, Grounding and Shielding - Circuits and In-
terference, Wiley, 2016.
3. Morrison, Fast Circuit Boards - Energy Management,
Figure 2 - An example of differential and common mode currents.
Wiley, 2018.
4. Smith and Bogatin, Principles of Power Integrity for
Besides SSN, common mode currents can also be created
PDN Design, Prentice-Hall, 2017.
by gaps in return planes, poorly terminated cable shields,
5. Sandler, Power Integrity - Measuring, Optimizing,
or unbalanced transmission line geometry. The problem is
and Troubleshooting Power Related Parameters in
that these harmonic currents tend to escape out along the
Electronic Systems, McGraw Hill, 2014.
outside of shielded I/O or power cables and radiate. These
6. Novak and Miller, Frequency-Domain Characteriza-
currents can be very small, on the order of μA. It takes just
tion of Power Distribution Networks, Artech House,
5 to 8 μA of current to fail the FCC class B test limit.
2007.
Introduction
While unrealistic to discuss all aspects of product design in a single article, I’ll try to describe the most common design
issues I find in the hundreds of client products I’ve had a chance to work on. These issues generally include PC board
design, cables, shielding, and filtering. More detailed information may be found in the Reference section below.
As previously mentioned, the top three product failures I run into include (1) radiated emissions, (2) radiated sus-
ceptibility, and (3) electrostatic discharge. Other failures can include things like conducted emissions, electrically fast
transient, conducted susceptibility, and electrical surge. Most of these last items are also the result of the same poor
product designs, which cause the top three failures.
NOTE: I prefer to avoid the word “ground” in this article or in my consulting practice. The reason is that there are too many misinterpretations,
which can also lead to EMC failures. It’s much more clear to use power and power return, and signal and signal return - or just “return plane” or
reference plane. Finally, cable shields or shielded enclosures are “bonded” together - not “grounded”. The only exception is the so called “safety
ground” or earth ground. But these have nothing at all to do with proper EMC design - just personal safety against electrical shock. I suppose
the one exception would be the earth ground connection on a three-wire power line filter. Also, occasionally, there will be an earth ground on a
PC board - especially for power supplies, but again, connecting a product or system to earth ground will not improve EMI, due to the very high
inductance (length) of the wire.
DESIGN FOR COMPLIANCE ESSENTIALS information on the physics of signal propagation through
PC boards.
PC BOARD DESIGN
The single most important factor in achieving EMC/EMI
compliance revolves around the printed circuit board de-
sign. It’s important to note that not all information sources
(books, magazine articles, or manufacturer’s application
notes) are correct when it comes to designing PC boards
for EMC compliance - especially sources older than 10
years, or so. In addition, many “rules of thumb” are based
on specific designs, which may not apply to future or
leveraged designs. Some rules of thumb were just plain
lucky to have worked.
Figure 1 - A propagating wave along a microstrip with reference plane. Figure,
PC boards must be designed from a physics point of view courtesy Eric Bogatin.
and the most important consideration is that high frequen-
cy signals, clocks, and power distribution networks (PDNs) In order to satisfy both the circuit and field theory view-
must be designed as transmission lines. This means that points, we now see the importance of adjacent power
the signal or energy transferred is propagated as an elec- and power return planes, as well as adjacent signal and
tromagnetic wave. PDNs are a special case, as they must signal return planes. PDN design also requires both bulk
carry both DC current and be able to supply energy for and decoupling “energy storage” capacitors. The bulk ca-
switching transients with minimal simultaneous switching pacitors 4.7 to 10 μF, typ.) are usually placed near the
noise (SSN). The characteristic impedance of PDNs is de- power input connector and the decoupling capacitors (1
signed with very low impedance (0.1 to 1.0 Ohms, typical- to 10 nF, typ) nearest the noisiest switching devices - and
ly). Signal traces, on the other hand, are usually designed most importantly, with minimal trace length connecting
with a characteristic impedance of 50 to 100 Ohms. these from the power pins to signal return plane. Ideally,
all decoupling capacitors should be mounted right over
The previous article introduced the concept of the circuit (or close to) the connecting vias and multiple vias should
theory and field theory viewpoints. A successful PC board be used for each capacitor to reduce series inductance.
design accounts for both viewpoints. Circuit theory sug-
gests that current flows in loops from source to load and Signal or power routed referenced to a single plane will
back to the source. In many cases of product failure, the always have a defined return path back to the source.
return path has not been well defined and in some cases, Figure 2 shows how the electromagnetic field stays with-
the path is broken. Breaks or gaps in the return path are in the dielectric on both sides of the return plane. The
major causes of radiated emissions, radiated susceptibil- dielectric is not shown for clarity.
ity, and ESD failures.
nal (or power) return plane. It’s also a good idea to run
multiple connecting vias between the two return planes
in order to guarantee the lowest impedance path back to
the source. The EMI performance will be significantly im-
proved using this, or similar designs. In many cases, sim-
ply rearranging the stack-up is enough to pass emissions.
Note that when running signals between the top and bot-
tom layers, you’ll still need to include “stitching” vias be-
tween the return planes and stitching capacitors between
Figure 3 - A signal trace passing through two reference planes. If the reference the power and power return planes right at the point of
planes are the same potential (signal or power returns, for example), then stitch- signal penetration in order to minimize the return path.
ing vias next to the signal via should be sufficient. However, if the planes are Ideally, these stitching vias should be located within 1 to 2
different potentials (power and return, for example), then stitching capacitors mm of each signal via.
must be installed very close to the signal via. Lack of a defined return path
will cause the electromagnetic field to leak around the dielectric, as shown, and Other Tips - Other design tips include placement of all
couple into other signal vias or radiate out board edges. power and I/O connectors along one edge of the board.
This tends to reduce the high frequency voltage drop be-
For example, let’s take a look at a poor (but very typical) tween connectors, thus minimizing cable radiation. Also,
board stack-up that I see often. See Figure 4. segregation of digital, analog, and RF circuits is a good
idea, because this minimizes cross coupling between
noisy and sensitive circuitry in the return plane.
es is shown in Figure 7. Note the harmonic currents are inch. See Reference 5 and 6 for more detail on shield-
10 to 15 dB higher for the gapped trace (in red). Failing ing. Interference Technology also has a free download-
to pay attention to the signal and power return paths is a able 2017 EMI Shielding Guide with excellent information
major cause of radiated emissions failures. (Reference 7).
Figure 7 - The resulting common mode currents on an attached wire (to the
return plane) as measured with a current probe. The trace in aqua is the un-
gapped return path and the trace in red, the gapped return path. The difference
is 10 to 15 dB higher for the gapped return path. These harmonic currents will
tend to radiate and will likely cause radiated emissions failures.
SHIELDING Figure 9 - A handy chart for determining resonant frequency versus cable or slot
The two issues with shielded enclosures is getting all length in free space. Half-wavelength slots simulate dipole antennas and are
pieces well-bonded to each other and to allow power or particularly troublesome. Figure, courtesy Patrick André.
I/O cable to penetrate it without causing leakage of com-
mon mode currents. Bonding between sheet metal may Cable Penetration - The number one issue I find when
require EMI gaskets or other bonding techniques. Slots tracking down a radiated emissions problem is cable ra-
or apertures in shielded enclosures become issues when diation. The reason cables radiate is that they penetrate a
the longest dimension approaches a half wavelength. shielded enclosure without some sort of treatment - either
bonding the cable shield to the metal enclosure or com-
mon mode filtering at the I/O or power connector (Figure
10 and 11). This occurs frequently, because most con-
nectors today are attached directly to the circuit board
and are then poked through holes in the shield. Once the
cable is plugged in, it is “penetrating the shield” and EMI
is the usual result.
Figure 8 - A chart of attenuation versus slot length. Figure, courtesy Henry Ott.
Figure 10 - Penetrating the shield with a cable defeats the shield. This example
Figure 8 shows a handy chart for determining the 20 dB shows how external energy sources can induce noise currents in I/O cables,
attenuation of a given slot length. For example, if a prod- which can potentially disrupt internal circuitry. The reverse is also true, where
uct design requires at least a 20 dB shielding effective- internal noise currents can flow out the cable and cause emissions failures. Fig-
ness, then the longest slot length can be just one-half ure, courtesy Henry Ott.
There are four combinations or cases that must be con- ical topology is shown in Figure 13. The “X” capacitor is
sidered: shielded or unshielded products, and shielded or designed to filter differential mode, while the CM choke
unshielded cables. Power cables are usually unshielded and “Y” capacitors are designed to filter common mode.
for consumer/commercial products and so require power The resistor shown is usually 100 kOhm and the purpose
line filtering at the point of penetration or at the connector is merely to bleed off the line voltage stored on the capac-
of the circuit board. Shielded cables must have the shield itors to a safe level.
bonded (ideally in a 360 degree connection) to the prod-
uct’s shielded enclosure. If the product does not have a
shielded enclosure, then filtering must be added at the
point of penetration or at the I/O connector of the PC
board. Figure 11 shows the usual result when connectors
simply poke through a shielded enclosure.
Figure 12 - A typical common mode filter used for I/O filtering. The two windings
are wound in opposite directions and so tend to cancel the common mode currents.
FILTERING
I won’t go into very much detail here, because Interfer-
ence Technology has an excellent EMI Filter Guide free
for the downloading (see Reference 8). Suffice to say,
filters, as well as transient protection, are important at
power and I/O connectors. Typically, these will be com-
mon mode topologies, as shown in Figure 12. Most sig-
nal-level common mode chokes may be obtained in sur-
face mount packaging. Power chokes are much larger to
handle the current and may be obtained as either surface
mount or through-hole mount, depending on the current
rating. Many Ethernet connectors also have built-in com- Figure 14 - Five common filter topologies, depending on the source and load
mon mode filtering. impedances. Figure, courtesy Würth Electronik.
Power supply input filters are generally designed to sup- For general purpose filtering of signals, the handy chart of
press both differential and common mode currents. A typ- possible filter topologies may be found in Reference 9 and
is reproduced here in Figure 14. The appropriate topolo- Power line surge protection usually requires much larger
gy depends on the source and load impedances. If these transient protection devices and they can come in a va-
impedances are not known, then either the “PI” or “T” to- riety of types. Gas discharge or metal oxide varistors are
pology may be used (#3 or #5 on the chart, respectively). the most common, but larger silicon-based devices are
also available. More information on the design of surge
Ferrite or inductive components should not be used in se- protection may be found in Reference 9.
ries with the power pins of ICs, as this will only reduce
the ability of the local decoupling capacitors to supply SUMMARY
required energy during simultaneous switching of the Most EMC/EMI failures are due to poor shielding, pene-
IC output stages with the resulting higher power supply tration of cables through shields, poor cable shield termi-
noise. If used, they should be inserted “upstream” from nation, poor filtering, and above all, poor PC board layout
the bulk capacitor. and stack-up. Paying attention to these common design
faults will pay off with a lower risk of compliance failures
Ferrite Chokes - One common filter element usually and result in lower project costs and schedule slippage.
added to I/O cables is the ferrite choke. Ferrite chokes
come in either the clamp-on types or solid cores meant REFERENCES
to be assembled along with the cable assembly. Often, 1. Bogatin, Signal Integrity - Simplified, Prentice-Hall,
these are used as a last resort to reduce cable emis- 3rd edition, 2018.
sions or susceptibility. 2. Morrison, Grounding and Shielding - Circuits and
Interference, Wiley, 2016.
Ferrite chokes have an associated impedance versus
frequency characteristic, often peaking around 100 to 3. Morrison, Fast Circuit Boards - Energy Management,
300 MHz. Some materials are designed to peak below Wiley, 2018.
100 MHz for lower frequency applications. Maximum im- 4. Wyatt, Gaps in Return Planes - Bad News for EMI
pedances can range from 25 to 1000 Ohms, depending (with video demo), https://interferencetechnology.
on the ferrite material used and style of choke. com/gaps-return-planes-bad-news-emi/
5. Ott, Electromagnetic Compatibility Engineering,
You may have noticed that clipping a ferrite choke onto a
Wiley, 2009.
cable sometimes has no effect. This is usually due to the
fact the choke has the same, or lower, effective imped- 6. André and Wyatt, EMI Troubleshooting Cookbook for
ance than the source and load impedances. The attenua- Product Designers, SciTech, 2014.
tion of a ferrite choke is easily calculated. 7. ITEM, 2017 EMI Shielding Guide, https://
i n t e r f e r e n c e t e c h n o l o g y. c o m / w p - c o n t e n t /
Attenuation (dB) = 20 * log((Zin + Zferrite + Zload) / (Zin + Zload)) uploads/2017/06/2017_IT_EMI-Shielding-Guide_
Low-Res.pdf
For example, if we add a 100 Ohm ferrite choke to a
power supply cable with system impedance of 10 Ohms 8. ITEM, 2017 EMC Filters Guide, https://
(source and load), the attenuation would be: i n t e r f e r e n c e t e c h n o l o g y. c o m / w p - c o n t e n t /
uploads/2017/05/2017-IT_EMC_Filters_Guide_Low-
Attenuation = 20 * log((10 + 100 + 10) / (10 + 10)) = 15.5 dB Res.pdf
9. Würth Electronik, Trilogy of Magnetics, 4th edition,
Refer to Reference 9 for much additional detail on ferrite 2010.
chokes and general filter design.
TRANSIENT PROTECTION
In order to protect internal circuitry from electrical tran-
sients, such as ESD, electrically fast transient (EFT), or
power line surge, due to lightning, transient protective
devices should be installed at all power and I/O ports.
These devices sense the transient and “clamp” the tran-
sient pulse to a specified clamp voltage.
Introduction
Input filters are today as ever a requisite factor for successful EMC validation of switching controllers, irrespective
of the size of the AC component involved. Switching controllers create conducted EMC interferences due to AC
components in their lines, independent of their individual topology and application. Certain component manufac-
turers have therefore optimized their power modules for a low line-bound and radiated emission of interferences.
These types of modules’ residual ripple generally exhibits a negligibly low value, meaning that an output filter can
be dispensed within most applications. Since the input current at the step-down converter is pulsating, this may
generate radio-frequency interferences in the application. Depending on the specific application, the hardware
developer decides whether an input filter is necessary directly before the power module or in another position in
the switch. The design process of input filters for optimized power modules and the measurement techniques that
are used is discussed in this article.
INPUT FILTERS – THE KEY TO SUCCESSFUL To reduce differential mode noises, at least one simple
LC filter must be fitted at the input of the converter as a
EMC VALIDATION measure to minimize the AC component in the line. In
high-impedance systems, such an input filter can theo-
As a starting point it is useful to illustrate how differential
retically produce a voltage attenuation of 40 dB/decade
mode noises develop in the first place. Differential mode
in the stopband. In practice, a lower degree of attenuation
noises are interference signals in a system with a sym-
is achieved since the terminating impedances are low-
metrical current back and forth between the source and
ohm in their nature and also because the components
the load in the lines of a switching controller.
themselves exhibit losses. In dimensioning the LC filter a
corner frequency fc is selected that is below the switching
frequency fsw of the power module. If the factor is one
tenth, theoretically an insertion loss of 40 dB is achieved
at the switching frequency at which the highest spectral
amplitude occurs.
(1)
(2)
Figure 1 – Symmetrical system
In the input circuit, the clock frequency of the power mod- As an example for the calculation of the filter, an induc-
ule includes an AC component superimposed over the tance of 10 μH is selected and Equation (2) is trans-
useful current and is similar in its configuration to the cur- formed to:
rent through the storage inductance of the power module.
The input current flows into the input capacitor Cin. Real (3)
capacitors possess a resistive component, the ESR, and
an inductive component, the ESL as shown in Figure 2. In arranging the filter components, as shown in Figure 3,
the filter capacitor can be positioned on the side of the
Due to the ESR of the input capacitor and the impedanc- voltage source or on the input side of the power module.
es of the lines of the power module, the AC component The decisive factor for the attenuation of the pulsating
produces an undesirable voltage drop. current drawn from the voltage source is the inductance
of the filter inductor.
In this form, the noise voltage shows up as a differen-
tial-mode signal. The amplitude of the interference voltage
occurring at the input capacitor is essentially dependent
on the ESR of the capacitor used. Electrolytic capacitors
have a relatively high ESR, the value of which can range
between just a few milliohms up to several ohms. As a
consequence, the interference voltage can vary between
a few millivolts up to several volts. Ceramic capacitors,
on the other hand, have a very small ESR of just a few
milliohms and thus result in a noise voltage of a few mil-
livolts. In addition, the circuit-board design of the power
module exerts a great effect on the interference voltage.
Figure 3 – Arrangement of the components of the input filter
(4)
Figure 2 – Development of the noise voltage In addition, the corner frequency fc of the input filter should
lie far below the crossover frequency fco of the power current in the input circuit. Figure 5 shows the impedance
module. curves of three rod core chokes based on an example of
the Würth Electronics WE-SD product family.
(5)
The length of the cable between the DUT and the LISN
should not exceed 80 cm. The EMI receiver evaluates the
asymmetric noise voltage that is decoupled at the LISN
for the separate leads of the cable.
CASE STUDY – MEASURED NOISE VOLTAGE This power module operates at a clock frequency of 370
The following section describes the measurement of the kHz. In the interference spectrum, the highest amplitude
noise volt-age using a Würth Elektronik MagI³C power (red peak: 68 dBμV) can be measured at this frequency.
module evaluation board fitted with a Variable Step Down The amplitude density of the noise voltage drops at a rate
Regulator Module (171 020 601) as an example. of approx. 40 dB/decade, meaning that no significant in-
terference level can be seen above the 15th harmonic.
Already during the preliminary phase it is possible to mea- Nevertheless, it is only above the 9th harmonic that the
sure the AC component at the power module’s input using interference level is more than 10 dB below the limit for
an oscilloscope. By running an analysis within the time the average detector (dark blue line).
domain, the anticipated interference spectrum can be es-
timated at the start of the work on the design of the filter. Equation (3) can now be used to calculate a suitable LC
input filter. Due to the relatively low switching frequency, Finally, the equations can be used to calculate an atten-
an inductor with a low SRF and an inductance of 4.7 μH uating resistance.
is selected and the filter capacitance is calculated.
(11)
(9)
The higher the value of the attenuation resistance, the
The selected filter capacitor is the one with a little higher higher the attenuation of the filter resonance. In this
capacitance of 10 μF. The maximum input current is cal- case, the next higher resistance of the E12 series of 1 Ω
culated using Equation (8). can be selected.
This calculation requires the efficiency of the evaluation A value of 47 μF is selected for the attenuation capacitor.
board, which is determined by measurement and in this This may be, for example, a Würth Elektronik eiCap ce-
case has a value of 91%. ramic capacitor of the WCAP-CSGP series.
SUMMARY
Irrespective of the size of the AC component involved,
an input filter is today as ever a requisite factor for a
successful EMC validation of a switching controller. Sim-
ple-to-apply equations can be used to calculate such an
input filter on an individual basis. Taking the impedances
of the filter and the switching controller into account in
Figure 13 – Noise voltage with an input filter the equations, this enables oscillations to be avoided and
also ensures the control stability of the switching con-
The interference level measured at the 370 kHz switching troller itself. A targeted selection of the filter components
frequency has a value of 30 dBμV. The levels of all har- lays the foundations for an optimal design of the filter.
monics are lower than 20 dBμV and are thus sufficiently Equipped with an appropriate degree of technical skill in
attenuated. The average level at 370 kHz corresponds to EMC testing methods, the hardware developer can de-
the peak level and is 18 dB lower than the average limit of sign his switch purposefully and, wherever necessary,
47 dBμV. In measuring such conducted interferences in make any adjustments to the filter himself.
the practical context, a signal-to-noise ratio of this dimen-
sion is entirely sufficient in order to confirm the conformity
of this measurement.
www.InterferenceTechnology.com
2021 EMC FUNDAMENTALS GUIDE
►COMMERCIAL STANDARDS
The following are some of the most common commercial EMC standards. Most standards have a fee associated and
most on the list are linked back to the source where they’re available. If you’re purchasing the printed version of this
guide, then refer to the Standards Organizations in the References section for standards purchase information. Note
that many Euro Norm (EN) versions of IEC standards may be purchased at a considerable discount from the Estonian
Centre for Standardization, https://www.evs.ee.
FCC
(https://www.ecfr.gov)
ANSI
(http://webstore.ansi.org)
IEC
(https://webstore.iec.ch)
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current
IEC 61000-3-2
emissions (equipment input current ≤ 16 A per phase)
Electromagnetic compatibility (EMC) - Part 6-5: Generic standards - Immunity for power
IEC 61000-6-5
station and substation environments
Electrical equipment for measurement, control and laboratory use – EMC requirements –
IEC 61326-1
Part 1: General requirements
Electrical equipment for measurement, control and laboratory use - EMC requirements
- Part 2-1: Particular requirements - Test configurations, operational conditions and
IEC 61326-2-1
performance criteria for sensitive test and measurement equipment for EMC unprotected
applications
Electrical equipment for measurement, control and laboratory use - EMC requirements
- Part 2-2: Particular requirements - Test configurations, operational conditions and
IEC 61326-2-2
performance criteria for portable test, measuring and monitoring equipment used in low-
voltage distribution systems
Electrical equipment for measurement, control and laboratory use - EMC requirements
IEC 61326-2-3 - Part 2-3: Particular requirements - Test configuration, operational conditions and
performance criteria for transducers with integrated or remote signal conditioning
Electrical equipment for measurement, control and laboratory use - EMC requirements
- Part 2-4: Particular requirements - Test configurations, operational conditions and
IEC 61326-2-4
performance criteria for insulation monitoring devices according to IEC 61557-8 and for
equipment for insulation fault location according to IEC 61557-9
Electrical equipment for measurement, control and laboratory use - EMC requirements
IEC 61326-2-5 - Part 2-5: Particular requirements - Test configurations, operational conditions and
performance criteria for field devices with field bus interfaces according to IEC 61784-1
Electrical equipment for measurement, control and laboratory use - EMC requirements -
IEC 61326-2-6
Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical equipment
Electrical equipment for measurement, control and laboratory use - EMC requirements -
IEC 61326-3-1 Part 3-1: Immunity requirements for safety-related systems and for equipment intended
to perform safety-related functions (functional safety) - General industrial applications
Electrical equipment for measurement, control and laboratory use - EMC requirements -
Part 3-2: Immunity requirements for safety-related systems and for equipment intended
IEC 61326-3-2
to perform safety-related functions (functional safety) - Industrial applications with
specified electromagnetic environment
Electrostatics - Part 3-1: Methods for simulation of electrostatic effects - Human body
IEC 61340-3-1
model (HBM) electrostatic discharge test waveforms
CISPR
(https://webstore.iec.ch)
Specification for radio disturbance and immunity measuring apparatus and methods -
CISPR 16-1-5 Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration
sites and reference test sites for 5 MHz to 18 GHz
Specification for radio disturbance and immunity measuring apparatus and methods
CISPR 16-1-6 - Part 1-6: Radio disturbance and immunity measuring apparatus - EMC antenna
calibration
Specification for radio disturbance and immunity measuring apparatus and methods
CISPR 16-2-1 - Part 2-1: Methods of measurement of disturbances and immunity - Conducted
disturbance measurements
Specification for radio disturbance and immunity measuring apparatus and methods
CISPR 16-2-2 - Part 2-2: Methods of measurement of disturbances and immunity - Measurement of
disturbance power
Specification for radio disturbance and immunity measuring apparatus and methods -
CISPR 16-2-3 Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance
measurements
Specification for radio disturbance and immunity measuring apparatus and methods
CISPR 16-2-4 - Part 2-4: Methods of measurement of disturbances and immunity - Immunity
measurements
Specification for radio disturbance and immunity measuring apparatus and methods -
CISPR TR 16-2-5 Part 2-5: In situ measurements for disturbing emissions produced by physically large
equipment
Specification for radio disturbance and immunity measuring apparatus and methods -
CISPR TR 16-3
Part 3: CISPR technical reports
Specification for radio disturbance and immunity measuring apparatus and methods - Part
CISPR TR 16-4-1
4-1: Uncertainties, statistics and limit modelling - Uncertainties in standardized EMC tests
Specification for radio disturbance and immunity measuring apparatus and methods
CISPR 16-4-2 - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation
uncertainty
Specification for radio disturbance and immunity measuring apparatus and methods -
CISPR TR 16-4-3 Part 4-3: Uncertainties, statistics and limit modelling - Statistical considerations in the
determination of EMC compliance of mass-produced products
Specification for radio disturbance and immunity measuring apparatus and methods
CISPR TR 16-4-4 - Part 4-4: Uncertainties, statistics and limit modelling - Statistics of complaints and a
model for the calculation of limits for the protection of radio services
Specification for radio disturbance and immunity measuring apparatus and methods
CISPR TR 16-4-5 - Part 4-5: Uncertainties, statistics and limit modelling - Conditions for the use of
alternative test methods
CISPR 17 Methods of measurement of the suppression characteristics of passive EMC filtering devices
Radio interference characteristics of overhead power lines and high-voltage equipment -
CISPR TR 18-1
Part 1: Description of phenomena
Radio interference characteristics of overhead power lines and high-voltage equipment -
CISPR TR 18-2
Part 2: Methods of measurement and procedure for determining limits
Radio interference characteristics of overhead power lines and high-voltage equipment -
CISPR TR 18-3
Part 3: Code of practice for minimizing the generation of radio noise
IEC 60601-1 General requirements for basic safety and essential performance
IEC TR 60601-4-3 Considerations of unaddressed safety aspects in the third edition of IEC 60601-1
FDA Center for Devices & Radiological Health (CDRH) SAE EMC Standards
https://www.fda.gov/MedicalDevices/default.htm http://www.sae.org/servlets/works/committeeHome.
do?comtID=TEVEES17
Federal Communications Commission (FCC)
www.fcc.gov VCCI (Japan, Voluntary Control Council for Interference)
http://www.vcci.jp/vcci_e/
Federal Standards
https://quicksearch.dla.mil/qsSearch.aspx
IMPEDANCE OF A WIRE
Assuming the rise time of a clock is 7% of the period, we Reflection coefficient (ρ), given fwd/rev power
can approximate the bandwidth as shown.
Gain,dBi-to-Antenna Factor
E-FIELD FROM Field Strength given watts, numeric gain, distance in meters
DIFFERENTIAL-MODE CURRENT
f = frequency (Hz)
E-FIELD FROM
COMMON-MODE CURRENT
L = length of wire (m) 0.5 oz. copper = 0.7 mils = 0.018 mm
d = measurement distance (3 m or 10 m, typ.) (Assump- Convert mils to mm: multiply by 0.0254 mm/mil
tion that the wire is electrically short)
Convert mm to mils: multiply by 39.4 mil/mm
Wavelength(m) = 300/f(MHz)
Half wavelength(ft.) = 468/f(MHz)
RESONANCE OF STRUCTURES
Use this chart to for determining the relative radiation versus size in wavelength.
Image Source: Bruce Archambeault.
LINKEDIN GROUPS
Electromagnetic Compatibility Forum
EMC Experts
EMC Troubleshooters
ESD Experts
EMI/EMC Testing
iNARTE
IEEE
COMMON SYMBOLS
A Amperes, unit of electrical current
AC Alternating Current
AM Amplitude modulated
DC Direct Current
Ratio of the electric field (E) to the magnetic field (H), in the far-field this is the characteristic impedance of free
E/H
space, approximately 377 Ω
EM Electromagnetic
FM Frequency modulated
I Electric current
Pd Power density, unit of measurement of power per unit area (W/m2 or mW/cm2)
R Resistance
RF Radio Frequency
W/m2 Watts per square meter, a unit for power density, one W/m2 equals 0.1 mw/cm2
ACRONYMS
(Antenna Factor) - The ratio of the received field strength to the voltage at the terminals of a receiving antenna.
AF
Units are 1/m.
(Absorber-Lined Chamber) - A shielded room with RF-absorbing material on the walls and ceiling. In many
ALC
cases, the floor is reflective.
(Amplitude Modulation) - A technique for putting information on a sinusoidal carrier signal by varying the
AM
amplitude of the carrier.
(Bulk Current Injection) - An EMC test where common-mode currents are coupled onto the power and
BCI
communications cables of an EUT.
CE (Conducted Emissions) - The RF energy generated by electronic equipment, which is conducted on power cables.
CE Marking The marking signifying a product meets the required European Directives.
CENELEC French acronym for the “European Committee for Electrotechnical Standardization”.
(Conducted Immunity) - A measure of the immunity to RF energy coupled onto cables and wires of an electronic
CI
product.
CISPR French acronym for “International Special Committee on Radio Interference”.
Conducted Energy transmitted via cables or PC board connections.
Coupling
A structure or medium that transmits energy from a noise source to a victim circuit or system.
Path
(Conducted Susceptibility) - RF energy or electrical noise coupled onto I/O cables and power wiring that can
CS
disrupt electronic equipment.
CW (Continuous Wave) - A sinusoidal waveform with a constant amplitude and frequency.
(Electromagnetic Compatibility) - The ability of a product to coexist in its intended electromagnetic environment
EMC
without causing or suffering disruption or damage.
(Electromagnetic Interference) - When electromagnetic energy is transmitted from an electronic device
EMI to a victim circuit or system via radiated or conducted paths (or both) and which causes circuit upset
in the victim.
(Electromagnetic Pulse) - Strong electromagnetic transients such as those created by lightning or
EMP
nuclear blasts.
(Electrostatic Discharge) - A sudden surge in current (positive or negative) due to an electric spark or
ESD secondary discharge causing circuit disruption or component damage. Typically characterized by rise
times less than 1 ns and total pulse widths on the order of microseconds.
(Equivalent Series Inductance) - Generally refers to the parasitic series inductance of a capacitor or
ESL
inductor. It could also include the extra series inductance of any connecting traces or vias on a PC board.
ESR (Equivalent Series Resistance) - Generally refers to the parasitic series resistance of a capacitor or inductor.
EU European Union.
EUT (Equipment Under Test) - The device being evaluated.
When you get far enough from a radiating source the radiated field can be considered planar (or
Far Field
plane waves).
FCC U.S. Federal Communications Commission.
(Frequency Modulation) - A technique for putting information on a sinusoidal “carrier” signal by varying
FM
the frequency of the carrier.
IEC International Electrotechnical Commission
(Industrial, Scientific and Medical equipment) - A class of electronic equipment including industrial
ISM
controllers, test & measurement equipment, medical products and other scientific equipment.
(Information Technology Equipment) - A class of electronic devices covering a broad range of equipment
ITE including computers, printers and external peripherals; also includes, telecommunications equipment,
and multi-media devices.
ACRONYMS
(Line Impedance Stabilization Network) - Used to match the 50-Ohm impedance of measuring
LISN
receivers to the power line.
(Multi-Layer Ceramic Capacitor) - A surface mount capacitor type often used as decoupling or energy
MLCC
storage capacitors in a power distribution network.
Near Field When you are close enough to a radiating source that its field is considered spherical rather than planar.
Noise Source A source that generates an electromagnetic perturbation or disruption to other circuits or systems.
OATS (Open Area Test Site) - An outdoor EMC test site free of reflecting objects except a ground plane.
(Power Distribution Network) - The wiring and circuit traces from the power source to the electronic
PDN circuitry. This includes the parasitic components (R, L, C) of the circuit board, traces, bypass
capacitance and any series inductances.
(Power Line Transient) - A sudden positive or negative surge in the voltage on a power supply input
PLT
(DC source or AC line).
(Power Integrity) - Refers to the quality of the energy transfer along the power supply circuitry from the
PI
voltage regulator module (VRM) to the die of the ICs. High switching noise or oscillations mean a low PI.
Radiated Energy transmitted through the air via antenna or loops.
(Radiated Emissions) - The energy generated by a circuit or equipment, which is radiated directly from the
RE
circuits, chassis and/or cables of equipment.
Radio Frequency Interference) - The disruption of an electronic device or system due to electromagnetic
RFI
emissions at radio frequencies (usually a few kHz to a few GHz). Also EMI.
Radiated Immunity) - The ability of circuits or systems to be immune from radiated energy coupled to
RI
the chassis, circuit boards and/or cables. Also Radiated Susceptibility (RS).
(Radio Frequency) - A frequency at which electromagnetic radiation of energy is useful for
RF
communications.
(Radiated Susceptibility) - The ability of equipment or circuits to withstand or reject nearby radiated RF
RS
sources. Also Radiated Immunity (RI).
Spread Spectrum Clock Generation) - This technique takes the energy from a CW clock signal and
SSCG spreads it out wider, which results in a lower effective amplitude for the fundamental and high-order
harmonics. Used to achieve improved radiated or conducted emission margin to the limits.
(Voltage Regulator Module) - A linear or switch-mode voltage regulator. Generally, there will be several
VRM
of these mounted to a PC board in order to supply different levels of required voltages.
(Voltage Standing Wave Ratio) - A measure of how well the load is impedance matched to its
VSWR transmission line. This is calculated by dividing the voltage at the peak of a standing wave by the
voltage at the null in the standing wave. A good match is less than 1.2:1.
(Crosstalk) - A measure of the electromagnetic coupling from one circuit to another. This is a common
XTALK
problem between one circuit trace and another.
INDEX OF ADVERTISERS