AccuPyc 1340 Specifications

Environment Temperature: Stable between 15 to 35 oC (59 to 96 oF )


Temperature-controlled AccuPyc: temperature stability is
dependent upon specifications of the installed circulator.
Recommended range: 15 to 50 oC (59 to 122 oF)

Humidity: 20 to 80% relative, non-condensing

Physical Height: 17.9 cm (7.0 in.), analysis modules for 1-, 10-, and 100-cm3
units, and control module
25.9 cm (10.2 in.), 350-cm3 analysis module
43.0 cm (17.0 in.), 2000-cm3 analysis module
Width: 27.3 cm (10.7 in.), control module
27.3 cm (10.7 in.), control module
27.0 cm (10.6 in.), 2000-cm3 analysis module

Depth: 36.2 cm (14.3 in.)

Weight: 9.3 kg (20.5 lbs), control/analysis unit (1-, 10-, and 100-cm3
units)
7.9 kg (17.4 lbs), analysis module (1-, 10-, and 100 cm3 units)
10.5 kg (23.2 lbs), analysis module (350-cm3 unit)
3.6 kg (8.0 lbs), control module
26.0 kg (57.0 lbs), 2000-cm3 analysis module

Electrical Voltage: 90 to 264 VAC

Power: 30 VA

Frequency: 50 to 60 Hz

Sample Chamber 1 cm3 chamber: 1.15 cm ID x 1.1 cm D (0.45 in. ID x 0.44 in. D)
10 cm3 chamber: 1.80 cm ID x 3.93 cm D (0.72 in. ID x 1.55 in. D)
100 cm3 chamber: 4.62 cm ID x 6.17 cm D (1.82 in. ID x 2.43 in. D)
350 cm3 chamber: 5.84 cm ID x 13.94 cm D (2.30 in. ID x 5.49 in. D)
2000 cm3 cham- 9.7 cm ID x 26.00 cm D (3.80 in. ID x 10.20 in. D)
ber:

Analysis Precision: Reproducibility typically to within ± 0.01% of the nominal


full-scale sample cell chamber volume. Reproducibility
guaranteed to within ±0.02% of the nominal full-scale
volume on clean, dry, thermally equilibrated samples using
helium in the 15 to 35 ºC range.

Accuracy: Accurate to within 0.03% of reading, plus 0.03% of sample


capacity.
Computer Hardware Minimum Requirements: A computer is not required if the keypad / display is
and Software used. When used in this configuration data can be sent
to a USB equipped printer.

To run the Windows compatible software the follow-


ing applies:

Pentium 333 MHz or equivalent


One CD ROM drive
128 megabytes of RAM
1-gigabyte hard drive
1024 x 768 video display capability
Windows 2000 or XP professional
Ethernet port (capable of communicating with a 10
base-T ethernet card)

Gases Research grade helium is recommended. If unavailable, use helium with a dew
point of -67 oC (-88 oF) or lower. Carbon dioxide, argon, dry air, or nitrogen can
also be used for different applications. A multigas option is available for connec-
tion of mulitple gases).

In keeping with a policy of ongoing product improvement, specifications are subject to change without notice.