Pole Calc
Pole Calc
A. MAIN POLE
FIGURES
GIVEN DATA:
Applied Axial Load, PA = 195.997 kN from Staad
Diameter of Base Plate, DB = 1630 mm
Thickness of Base Plate, TB = 65 mm
Diameter of Steel Pipe, DP = 1348 mm
Stiffener Height, H = 300 mm
Base Length of Stiffener, L = 140 mm
Thickness of Stiffener, t = 20 mm
Length of Cantilever Connection, CL = 141 mm (DB/2 - Dp/2 - L)
Length of Simply Supported Connection, Ls = 264.7 mm (R*Interior Angle)
Yield Stress of Steel, fy = 248 MPa
A1 = 2086724 mm2
A2 = 3300636 mm2
Compressive strength of concrete, fc = 21.00 Mpa
BEARING CAPACITY
Allowable Bearing Stress of Concrete
Fp = 0.85 f'c - on full area of a concrete support
Fp = 0.85 f'c * (A2/A1)^(1/2) ≤ 1.7f'c - on less than the full area of a concrete support
where; A1 = Area of Steel concentrically bearing on concrete support
A2 = Maximum area of the portion of the supporting surface that
is geometrically similar to and concentric with the loaded area
Fp = 22.449
ts
300 mm
H
65 mm
` 265 mm
320 DB
W
TRIBUTARY AREA
265 140 mm
A. MAIN POLE
FIGURES
GIVEN DATA:
Applied Axial Load, PA = 0.958 kN from Staad
Length of Base Plate, LB = 250 mm
Width of Base Plate, WB = 250 mm
Thickness of Base Plate, TB = 10 mm
Diameter of Steel Pipe, DP = 114.3 mm
Stiffener Height, H = 105 mm
Base Length of Stiffener, L = 68 mm
Thickness of Stiffener, t = 7 mm
Length of Cantilever Connection, CL = 67.85 mm (DB/2 - Dp/2 - L)
Length of Simply Supported Connection, Ls = 125 mm (R*Interior Angle)
Yield Stress of Steel, fy = 248 MPa
A1 62500 mm2
A2 184900 mm2
BEARING CAPACITY
Allowable Bearing Stress of Concrete
Fp = 0.35 f'c - on full area of a concrete support
Fp = 0.35 f'c * (A2/A1)^(1/2) ≤ 0.7f'c - on less than the full area of a concrete support
where; A1 = Area of Steel concentrically bearing on concrete support
A2 = Maximum area of the portion of the supporting surface that
is geometrically similar to and concentric with the laded area
Fp = 12.642 MPa ≤ 14.7 Mpa OK!!!!
t
s
105 mm
H
10 mm
` 125 mm
125 DB
W
TRIBUTARY AREA
125 68 mm
ANCHOR RODS:
For anchors rods, the following interaction shall be satisfied:
FIGURE :
GIVEN DATA :
Applied Loads Pshear = 1.104 kN
Ptension = 0.044 kN
Diameter of Bolts: d = 16 mm
Diameter of Hole: d = 18 mm
Effective Area: A = 145.81 mm2
Bearing Area of Head: Ab = 292.90 mm2
Number of Bolts : n = 4 pcs
fv = Pshear / Av
fv = Ptension / As
FIGURE :
CONCRETE PROPERTIES
GIVEN DATA :
Pullout Strength
fN = f Ψ (Ab 8fc') (English)
y term is 1.0 for location where concrete cracking is likely to occur.
fN = 8.30 kips The pullout strength in tension of a single headed stud or bolt
fN = 36.91 kN SAFE
National Structural Code of the Philippine (NSCP Vol. 6), Section 412.7.2
FIGURE :
GIVEN DATA :
Applied Loads Pshear = 2.202 kN
Ptension = 3.149 kN
Diameter of Bolts: d = 16 mm
Diameter of Hole: d = 18 mm
Effective Area: A = 145.81 mm2
Bearing Area of Head: Ab = 292.90 mm2
Number of Bolts : n = 4 pcs
fv = Pshear / Av
fv = Ptension / As
FIGURE :
CONCRETE PROPERTIES
GIVEN DATA :
Pullout Strength
fN = f Ψ (Ab 8fc') (English)
y term is 1.0 for location where concrete cracking is likely to occur.
fN = 8.30 kips The pullout strength in tension of a single headed stud or bolt
fN = 36.91 kN SAFE
National Structural Code of the Philippine (NSCP Vol. 6), Section 412.7.2