MNO Manuale Vuoto Inglese
MNO Manuale Vuoto Inglese
MNO Manuale Vuoto Inglese
4_01-2023)
OPERATING MANUAL
LIQUID RING VACUUM PUMPS
AND COMPRESSORS
Series
TRH - TRS - TRM - TRV - SA
&
Systems type
HYDROSYS - OILSYS
OPERATING MANUAL FOR INSTALLATION,
START-UP AND MAINTENANCE FOR LIQUID
RING VACUUM PUMPS AND COMPRESSORS
This manual applies to TRAVAINI liquid ring pumps single stage series TRM, TRS, TRV, double stage series TRH,
compressors series SA and systems series HYDROSYS and OILSYS, which utilize above pump series. (Please see
chapters 20 or 21 for details pertaining to systems).
NOTE: Unless otherwise specified, the term pump used throughout this manual means also pump/motor assembly or
system type HYDROSYS and/or OILSYS.
Manufacturer:
POMPETRAVAINI S.p.A.
Via per Turbigo, 44 - 20022 CASTANO PRIMO - (Milano) - ITALY
Tel. +39 0331 889000 - www.pompetravaini.com
WARRANTY: All products manufactured by POMPETRAVAINI are guaranteed to meet the conditions listed on the
general terms & conditions of sales and/or conditions listed on the order confirmations.
Failure to strictly adhere to the instructions and recommendations listed in this manual, will void the
manufacturer’s warranty. Guarantee will be preserved only if the pump maintenance is carried out by
Pompetravaini or an authorized service. Any modification introduced to the pump without the
authorization of Pompetravaini will lead to the loss of the guarantee.
If it is strictly necessary to dismantle the pump, please consult Disassembling Instructions on our website
"www.pompetravaini.com”.
i
This manual is valid only for the listed pump series. This manual IS NOT for the total installation. Instruction and
maintenance manual for the installation must be obtained from the engineer that designed the installation.
Furthermore, the installation manual will take precedence over the pump manual.
The liquids handled by the pumps and also their parts could be potentially dangerous for persons and
environment: provide their possible disposal in conformity with the laws into force and a proper environment
management.
The present manual is not assigned for pumps subjected to the ATEX 2014/34/EU directive. In case the pump
is assigned in environments subjected to the application ATEX 99/92/CE directive or in case the pump is
provided with a nameplate indicating the ATEX stamp, it strictly forbidden proceed to start up the pumps but
necessary to consult POMPETRAVAINI for clarifications.
For pumps subjected to the ATEX 2014/34/EU directive it is available a dedicated integrative manual.
According to what expected from 2012/19/UE Directive on Waste Electric and Electronic Equipment the electrical
pump assembly from us supplied (pump coupled with an electrical motor of Pompetravaini supply or customer supply)
placed on the market after the 15th of August 2018 fell within the limits of application of the Directive. As a consequence,
conforming to article 14 of the 2012/19/UE Directive of the European Parliament of the 4th of July 2012, Pompetravaini
Spa is registered on the Italian list of EEE manufacturer.
The electrical pump assembly supplied by Pompetravaini Spa that should be discontinued from use must not be
disposed with common waste because it is composed of different materials that can be recycled at the appropriate
facilities. If it is not intended to proceed autonomously at the management of the electrical pump assembly at authorized
disposal companies it is possible to contact the Pompetravaini branch closer to you that will give you the necessary
information on a proper disposal in accordance with mandatory laws.
The pump unit must be previously cleaned up by the pumped product upon disposal.
After reclamation the electrical pump assembly is not potentially dangerous for human health and environment, not
containing harmful substances according to 2011/65/UE (RoHs) Directive, but if abandoned in the environment will
have a negative impact on the ecosystem. Sending the electrical pump assembly to an adequate process of disposal
and recovery of materials protect the environment and help to limits consumption of available resources with effective
recycling of materials. The abandonment in the environment of the apparatus or the illegal disposal of the same
are punished by law.
In preparing this manual, every possible effort has been made to help the customer and operator with the proper installation and operation of the pump
and/or system. Should you find errors, misunderstandings or discrepancies please
do not hesitate to bring them to our attention.
Continuing research of POMPETRAVAINI results in product improvements: therefore, any specifications may be subject to change without notice.
2 Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS
INDEX
1 - General instructions 9 - Electrical connections
1.1 - General instruction 10 - Check list prior to start-up
1.2 - Reading template 11 - Starting, operating and stopping procedures
2 - Safety instructions 11.1 - Start-up
3 - In case of emergency 11.2 - Operation
3.1 - Basic first aid 11.3 - Shut down
4 - Pump outlines 11.4 - Start-up of “OILSYS” systems
4.1 - Principle of operation 11.5 - Operation of “OILSYS” systems
4.2 - Service liquid properties 11.6 - Shut down of “OILSYS” systems
4.3 - Pump models and tables for material of 12 - Operating maintenance
construction 12.1 - “OILSYS” systems
5 - Unpacking, lifting and moving instructions 13 - Bearings maintenance
6 - Storage instructions 14 - Packed stuffing boxes
7 - Installation instructions 15 - Mechanical seals
7.1 - Piping connections 16 - Trouble shooting:
7.2 - Accessories problems, causes and solutions
7.3 - Installation schematics for vacuum pumps 17 - Repairing and removing pump from the
7.3.1 - Service liquid: installation
Once-through system (no recovery) 18 - Spare parts
7.3.2 - Service liquid: Partial recovery system 19 - Engineering data
7.3.3 - Service liquid: Total recovery system 19.1 - Influence of service liquid temperature,
7.4 - Installation schematics for compressors specific gravity and viscosity on pump
7.5 - Installation of “HYDROSYS” systems performance
7.6 - Installation of “OILSYS” systems 19.2- Service liquid temperature change across
7.7 - Service liquid (H2O at 15°C) flow (in m3/h) for the pump
vacuum pumps 19.3 - Operation with partial recovery of service
7.8 - Service liquid flow (H2O at 15°C) and pressure liquid
for compressors series “SA” 19.4 - Units conversion table
7.9 - Typical installation schematics for vacuum 20 - Engineering data for “HYDROSYS” systems
pumps 21 - Engineering data for “OILSYS” systems
7.10 - Typical installation schematics for 21.1 – Lifting and moving of “OILSYS” systems
compressors
7.11 - Connections location
7.12 - Pump engineering data
8 - Mounting and alignment instructions
8.1 - Assembly of base mounted pump unit
8.2 - Alignment procedures for monoblock and for
pump/motor assembly on baseplate
8.3 - Alignment instructions
KEY TO SYMBOLS
Signals for the operator’s safety.
i
DANGER: indicates imminent conditions of
Indications for the pump preservation danger of serious harm or death.
CAUTION: indicates a possible danger of minor
harm.
Warnings for the environment safeguard Electric dangers for the operator’s safety.
Pompetravaini ensures that its documentation is compliant in Italian and English languages.
Technical documentation and manuals provided in languages other than these two are subject to a translation
by third parties.
Documentation and manuals in the two official languages are available on the Pompetravaini website.
Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS 3
1 - GENERAL INSTRUCTIONS
IMPORTANT!
The pump is to be used only for the applications specified on the confirming order for which POMPETRAVAINI
has selected the design, materials of construction and tested the pump to meet the order specifications.
Therefore the pump CANNOT be used for applications other than those specified on the order.
i In the event the pump is to be used for different applications, please contact the sales office or representative
of the manufacturer. POMPETRAVAINI declines to assume any responsibility if the pump is used for different
applications without prior written consent confirmation.
Pumps are for industrial and continual use in installations fit for the purpose by authorized and trained personnel.
The use in unfit or unprotected installations, without proper precautions preventing the contact with untrained
personnel or children, is strictly forbidden
If construction and operation data of the pump in question are not available must be ISO 9001 Certified
requested to POMPETRAVAINI specifying the type and serial number printed on the S.p.A.
nameplate (see example at side) easily identifiable on the pump itself: always refer to 20022 CASTANO PRIMO (MILANO) - ITALY
it to request additional technical information and/or ordering spare parts. PUMP TYPE
The user is responsible for the verification of the ambient conditions where the pump
SERIAL NO. YEAR
will be stored or installed. Extreme low or high temperatures may severely damage the ITEM
pump or system unless proper precautions are taken. Q m3/h KW abs.
H m.c.l. mbar
POMPETRAVAINI does not guarantee repairs or alterations done by user or other
unauthorised personnel.
Special designs and constructions may vary from the information given in this manual. Please contact POMPETRAVAINI
should you have any difficulty or doubt.
NOTE: Drawings appearing in this manual are only schematics. These drawings are not for construction.
For construction drawings contact POMPETRAVAINI or the authorised local representative.
1.2 - READING THE INFORMATIONS MARKED ON PUMP’S NAMEPLATES AND SERVICE CARDS
The machinery Directive 2006/42/EC and the ATEX Directive 2014/34/EU require the marking of certain information on
the pump’s nameplates. The pump nameplate must be applied so that it is not easily removable and remains legible for
long time.
Furthermore, according to the regulations in force, it is necessary to provide the machines with a document, the
Declaration of Conformity, to the safety requirements imposed by the Machinery Directive for all pumps (usually named
as EC Declaration of Conformity) and to the ATEX Directive for pumps intended for use in environments subject to the
directive (usually named ATEX Declaration of Conformity).
Pompetravaini has chosen to make each Declaration supplied with the pump’s documentation unique, applying on it an
adhesive tag that incorporate the information of the pump nameplate applied on the pump.
In this way each Declaration of conformity is uniquely identified with the same serial number as the pump for which it was
issued. By convention in Pompetravaini this tag is called Service Card.
The pump nameplate must bear all the all the mandatory information required by the applicable directives (Machinery
Directive and ATEX Directive if requested). The appearance and arrangement of the markings on the nameplate may
differ depending on the type of pump and the recipient of the pump. Or for some branches of Pompetravaini customized
executions are provided. The minimum information required by the regulations remains present in the various possible
configurations.
The vacuum system packages are provided with a single nameplate that identify them as an assembly of pump, or pumps,
with vessel and accessories. The system nameplate is applied on the body of the vacuum pump (or on the pumps if the
system has more than one) and the serial number is unique for the whole system.
4 Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS
For Pompetravaini everything that is supplied as a vacuum package, identified by the serial number on the nameplate
and for the bill of material associated to the serial number, it is integral part of the package and therefore included in the
EC Declaration of Conformity and also ATEX Declaration of Conformity if required by the Order Confirmation.
The lasts are the ATEX markings, that begin with a string of characters identifying the level of protection of the pump. The
first row is the ATEX marking that refer to a use in a Zone classified for Gas. The second row is the ATEX marking that
refer to a use in a Zone classified for Dust.
There could be another string, for example for the Technical File 8TCx19R006) if necessary.
There are also symbols identifying some particularities of the pumps and systems.
The EC symbol identify a product subject to the Machinery Directive 2006/42/CE.
The trash bin symbol identify a product subject to the WEEE Directive 2012/19/EU
The symbol EX identify a pump that is also subject to the ATEX Directive 2014/34/EU
The Service Card tag applied on the Declaration of Conformity of the pump or vacuum system shows:
La Service Card applicata sulle Dichiarazioni di Conformità della pompa o dell’impianto riporta:
- Name of the manufacturer and address: Pompetravaini spa
- Issue date of the Service Card, es.: 01/04/2020
- Barcode identifying the production order
- Confirmation of Order number, es.: 2001864
- Serial number es.: HD114
Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS 5
- Pump code, es.: BA265A00207
- Pump type, es.: Centrifugal pump- Pompa centrifuga
- Model, es.: TBA 651/2-R/RA
- Weight, kg, es.: 116
- Pumped fluid, liquid or gas, es.: Acetone
- Portata richiesta, Q, m3/h: 16
- Potenza assorbita, kW, es.: 7,5
- Turn by minute/rpm, es.: 1450
- Pump head, for centrifugal pumps, m.c.l., es.: 46,8
- Suction pressure, for vacuum pumps, P in mbar, or discharge P out – mbar, for vacuum pumps
- ATEX markings (when applicable), es.: II 2 G Ex h IIB T4 Gb TBx19R006
The Service Card bears all the information of the pump nameplate and still others more as complement.
For the management system of Pompetravaini, starting with the serial number of the pump or vacuum system it is possible
to uniquely identify the product code and its bill of material.
This allows to associate everything provided with the order confirmation sent to the customer.
The code shown on the Service Card includes the pump as the main element, but also the electric motor, vessel or other
equipment and instruments included in the supply and included in the bill of material corresponding to the code.
On the Service Card are not marked the same symbols of the nameplate because it is requested by the norms and to
have more space for other information.
The EC Declaration of Conformity on which the Service Card is applied, such as the declaration of conformity to the ATEX
Directive, they are thus inclusive of everything that is part of the bill of materials associated with the specific code.
Pompetravaini has taken care of assessing that all other equipment and accessories supplied and included in the bill of
material are compliant with CE and ATEX requirements and guarantee a degree of protection equal to or higher than that
of the pump they are coupled to.
Each device, instrument or accessory has been selected and assembled by Pompetravaini according to the
manufacturer's instructions and so as not to compromise its certifications which are provided together with the
Pompetravaini documentation.
In the case of pump assemblies coupled with other accessories subject to the ATEX Directive 2013/34 / EU, all the
certifications of the individual components issued by their manufacturer remain valid, Pompetravaini has brought
everything together in a functional whole.
In this case the ATEX marking is for a vacuum system intended for an application with an atmosphere classified as Zone
0 inside and Zone 1 outside, therefore it includes the code of the certificate received from the Notified Body
(PTB06ATEX4001X) and the code of the Notified Body that deals with production surveillance (1370).
6 Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS
2 - SAFETY INSTRUCTIONS
CAUTION:
CAREFULLY READ FOLLOWING INSTRUCTIONS.
Strictly adhere to the instructions listed below to prevent personal injuries and/or equipment damage.
- ALWAYS apply the pump for the conditions outlined on the confirming order.
- Be ALWAYS informed on locations of first aid sites inside the company and carefully read safety and medical first aid
prescriptions in force.
- ALWAYS have a fire extinguisher in the vicinity of the pump installation.
- Any work on the pump must ALWAYS be carried out by at least 2 qualified people and expressly authorized.
- Electrical connections on the motor or accessories must ALWAYS be carried out by authorised personnel and in
accordance to the local codes.
- When approaching the pump ALWAYS be properly dressed (avoid use of clothes with wide sleeves, neckties,
necklaces, etc.) and/or wear safety equipment (hard hat, safety glasses, safety shoes, etc.) adequate for the work to
be done. Also refrain from wearing long and loose hair.
- DO NOT attempt to remove the safety guards when the pump is operating.
- After completion of the work ALWAYS re-install the safety guards previously removed.
- DO NOT operate the pump in the wrong direction of rotation.
- NEVER put hands or fingers in the pump openings or holes.
- ALWAYS disconnect the power to the motor prior to working or removing the pump from the installation.
- Make sure you have taken the necessary steps to prevent a possible inadvertent return of tension.
- Ensure the proper isolation of the components and ground connection before inserting the tension.
- ALWAYS stop the pump prior to touching it for whatever the reason. Wait for the complete pump stopping and make
sure that all the installation control devices are properly set in order to avoid any return flow.
- Pump and piping connected to the pump must NEVER be under pressure when maintenance or repair is carried out.
- NEVER work on the pump when it is hot.
- NEVER touch pump or piping having temperatures higher than 70°C or lower than -10°C.
- ALWAYS be careful when handling pumps that convey acids or hazardous fluids.
- NEVER step on pump and/or piping connected to the pump.
- ALWAYS make sure that the pump is permanently fixed and steady to the installation (i.e. during removal, handling,
installation, etc.)
DANGER!
Possible contact with hazardous media and hazardous substances There are certain components in the pump
which may be dangerous to people coming in their contact even during normal operation procedures and/or
maintenance, see table 1.
Take care of their possible disposal according to the laws into force and to a safe local environment
management.
CAUTION!
Danger due to smokes or vapours. In case smokes or vapours are released by the pump do not inhale and
immediately stop the pump for inspection.
Tab. 1
MATERIAL USE POSSIBLE DANGER
General lubrication, ball or roller
Oil and Grease Skin and eye irritation
bearings
Plastic and elastomer O-Ring, V-Ring, Splash ring,
Release of fumes and vapours when overheated
components Oil seals
Release of dangerous powders, release of fumes
Teflon & Kevlar fibres Packing rings
when overheated
Release of powder and fumes in case of rework,
Varnishes Exterior pump surface
flammable
Liquid compound Gasket between flat surfaces Skin, eye and breathing organs irritation
Protective liquid Pump inside surface Skin and eye rash
3 - IN CASE OF EMERGENCY
Should the pump break down leak gas and/or service liquid, immediately disconnect the electrical power following the
instructions given in chapter 11. Alert the maintenance personnel, at least two people should intervene using precautions
as it is required for the specific installation: pump may be handling dangerous and/or hazardous fluids.
After correction of all the problems that created the emergency situation, it is necessary to carry out all the recommended
starting procedures (see chapter 10).
4 - PUMP OUTLINES
The instructions given in this manual are for liquid ring vacuum pumps and compressors and for systems type
HYDROSYS or OILSYS which utilize said pumps.
NOTE: Capacities, vacuum and pressures are nominal and are the maximum attainable values under standard
operating conditions. Please contact POMPETRAVAINI for data on liquid ring compressors series TR…
T R H C 80 - 750 / C - M / GH - Z
T Manufacturer POMPETRAVAINI C C = Shaft sealing by mechanical seal
R Liquid ring pump B = Shaft sealing by stuffing box
M and V = Single stage pump with high vacuum M Monoblock design with motor flange
H S = Single stage pump with medium vacuum (upon request)
H = Two stage pump with high vacuum GH Material of construction
C Revision of hydraulic design GH - F - RA - A3 (see following table)
80 Ø Flange size (mm) Z Special design
750 Nominal capacity in m3/h
T R V X 100 7 / 1 - C / A3 - M / Z
T Manufacturer POMPETRAVAINI 1 Constructive project number
R Liquid ring pump C Shaft sealing by mechanical seal
8 Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS
V M e V = Single stage pump with high vacuum A3 Material of construction
X Stainless steel hydraulic plate version F - RX - A3 (see following table)
100 Ø Flange size (mm) M Monoblock design with motor flange
7 Nominal size rate Z Special design
Models for systems HYDROSYS and OILSYS are made out of a number which indicates the system size, followed by the
pump model number which is fitted in the system.
(ex.: HYDROSYS 5 – TRHB 50-420/C – M / GH).
Upon receipt verify that the material received is in exact compliance with that listed on the packing slip.
DANGER!
Danger due to cut, prick or abrasion. Take immediate actions to dispose of possible packaging parts that may
generate injuries or risks (for example edges, nails, splinters, etc.).
Organize the right management of materials subjected to controlled and differentiate disposal according to the
laws into force and to a safe environment management. The packaging could consist of the following materials:
wood FOR50 and/or cardboard PAP20 and/or cellophane LDPE 04 and/or stretch wrap PE-LD 04 and/or
polystyrene PS06 and/or packing strap PET1, PP05 (D.l.gs. 116/2020 and Decision 97/129/CE).
If the pump will be stored, as foreseen in our Operating Manuals, we recommend a proper care to avoid oil
dropping on the ground.
The pump or assembly must ALWAYS be moved and transported in the horizontal position.
Prior to moving the unit find the following:
- total weight
- center of gravity
- maximum outside dimensions
- lifting points location.
DANGER!
Danger due to overturning or crushing. For safe lifting to prevent material damages and/or personal injuries, it
is recommended to use ropes, or belts properly positioned on the pump and/or lifting eyebolts and make correct
movements.
Operate provided with apposite protective devices.
(For the Oilsys systems see chapter 21).
Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS 9
CAUTION!
Possible contact with fluids or harmful substances. Before removal after a period of operation, the pump,
together with auxiliary piping and jacketing, must be drained and decontaminated from the handled media.
Every hole and opening communicating with the inside of the pump must be properly plugged.
For removing the pump from the installation see chapter 19. Operate provided with apposite protective devices.
Fig. 2
Fig. 1
OK
(For the Oilsys systems see chapter 21)
----------------------------------------------------------------------------------------------------------------------------- --------------------------------
Fig. 3
>90°
NO
Fig. 4
10 Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS
6 - STORAGE INSTRUCTIONS
After receipt and inspection, if not immediately installed, the unit must be repackaged and stored.
For a proper storage proceed as follows:
- store the pump in a location that is closed, clean, dry and free of vibrations
- do not store in areas with less than 5°C temperature (for lower temperature it is necessary to completely drain the
pump of any liquids that are subject to freezing).
POSSIBILITY OF FREEZING!
i
Where the ambient temperature is less than 5°C it is recommended to drain the pump, piping, separator, heat
exchanger, etc. or add an anti-freeze solution to prevent damage to the equipment.
It is possible to use as antifreeze a mixture of surface-active glycol or other suitable products making sure they
are compatible with both pump gaskets and elastomers.
- fill the pump with a rust-preventative liquid that is compatible with the pump gaskets and elastomers. Rotate the shaft
by hand to impregnate all internal surfaces. Drain the excessive liquid from the pump and associated piping (see
chapter 11).
Please note that the pumps with cast iron internal parts have been treated at the factory, prior to shipment, with a rust-
preventative liquid: this liquid is capable of protecting the pump against rust for a period of 3 to 6 months.
A further solution, for long term storage, is to fill the pump with the rust inhibitor, rotate the pump shaft by hand to
eliminate any air pockets (the liquid must be suitable with gasket, elastomers and pump materials).
- plug all openings that connect the pump internals to the atmosphere
- protect all machined surfaces with an anti-rust material (grease, oils, etc.)
- cover the unit with plastic sheet or similar protective material
- rotate pump shaft at least every three months to avoid possible rust build-up or seizing
- keep the pump in a dry and clean place not subjected to vibrations caused by other sources
- pump accessories should be subjected to similar procedure.
7 - INSTALLATION INSTRUCTIONS
CAUTION!
Avoid installing the unit in narrow areas and lacking of ventilation where unfavorable conditions for the personnel
may take place. Allow the personnel a good visibility of the pump assembly by providing a proper lighting.
CAUTION!
A proper pump installation must not transmit vibrations to ambient in the permanent presence of personnel.
Information to determine the piping sizes and floor space requirements can be obtained from dimension drawings and
other engineering data. The information required is:
- size and location of suction and discharge flanges
- size and location of service liquid connection and connections for cooling, heating, flushing, draining, etc.
- location and size for mounting bolts for monoblock pump and/or baseplate and/or frame.
In the event additional accessories are required to complete the installation such as separators, piping, valves, etc. refer
to chapters 7.2 to 7.8.
Proper lifting devices should be available for installation and repair operations.
Pump assembly should be installed in an accessible location with adequate clear and clean space all around for
maintenance, so that an efficient and proper installation can be made.
It is important to have proper room around the unit for ventilation of motor and air cooled radiator, if applicable. Avoid
installing the unit in hidden locations, dusty and lacking of ventilation (minimum 0,6 meters of empty room around).
Select a mounting pad that will minimize vibrations or torsion of the pump baseplate or frame. It is generally preferred to
have a concrete base or sturdy steel beams. The installation must not transmit vibrations to the pump.
It is important to provide adequate anchor bolting for the pump frame or baseplate to be firmly attached to the foundations
(see fig. 5).
BASEPLATE
SPACER
CONCRETE
ANCHOR BOLT
Fig. 5
Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS 11
Concrete pads and other concrete works must be aged, dry and clean before the pump assembly can be positioned in
place. Complete all the work relating to the foundations and grouting of the pump assembly, before proceeding with the
mechanical and electrical portion of the installation.
CAUTION!
Possible contact with hazardous media and hazardous substances, cold or warm.
Be sure to pipe the correct connection from the installation to the respective pump connection ! operate only
provided with apposite protective devices.
To prevent any limb or foreign matters from entering the pump during installation, do not remove protection cap from
flanges or cover from openings until the piping is ready for hook-up.
Verify that all foreign objects such as welding bits, bolts, nuts, rags and dirt are removed from piping, separators, etc.
before these are connected to the pump.
Flanges should be connected parallel with each other, without stress and with bolt holes lined up. The weight of the pipe
must not weigh on the pump.
The flange gaskets should not interfere with the inside diameter of piping and/or flange.
i All piping must be independently supported, easily located and must not transmit forces or torque to the pump
due to the weight or to thermal expansions.
Piping size must never be less than the respective connection on the pump.
Suction and discharge flanges are vertical and identified with arrows.
To minimize friction losses and back-pressures, the discharge piping should be one size larger than the pump connection
size. To avoid back-pressure and possibility of flooding the pump when it stops, it is recommended to limit the rise of the
discharge piping to approximately 50 cm above the pump discharge flange.
Upon completion piping and connections should be tested for leakage under vacuum.
7.2 - ACCESSORIES
Listed below are common accessories that may be supplied with the pump or added at a later date. See fig. 6 to 15 for
locations and connection sizes on the pumps.
Vacuum gauge
Usually installed under the pump suction flange, will provide an indication of the pump operating vacuum (pressure).
Heat exchanger
It cools the service liquid for those systems with total liquid recovery: it can be plate and frame type, shell and tube type
or radiator type, depending upon the application.
Filter
Required to stop solids from entering the pump suction. Sizing of the filter is very important as it could create excessive
pressure drops which would affect the pump performance.
12 Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS
7.3 - INSTALLATION SCHEMATICS FOR LIQUID RING VACUUM PUMPS
CAUTION!
Possible contact with hazardous media and hazardous substances, cold or warm. Operate only provided with
apposite protective devices.
The working principle of the vacuum pump requires a continuous flow of fresh and clean liquid that enters the pump at
the service liquid connection identified by the letter Z (see chapter 7.11). The liquid is discharged together with the handled
gas through the pump discharge flange.
Dispose the waste liquids according to the current regulations protecting the environment. The obtained liquid-
water mixture must be collected and, according to the environmental disposal regulations, treated as special
liquid.
The quantity of said liquid will vary with pump size and degree of working vacuum (see performance curves and/or tab. 2).
The service liquid absorbs the compression heat generated by the pump compression therefore its temperature will rise
by some 3-4°C (for additional information see chapter 19).
There are three basic installation schematics listed below that may be considered, depending upon the quantity of service
liquid that is desired and possible to be recycled.
Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS 13
Separator/reservoir is considered a pressure vessel and as such it must be engineered and built to the applicable codes
(ISPESL, ASME, PED, etc.). Accessories such as pressure relief valve, check valve(non-return valve), automatic float
type drain valve(water trap), etc. are required in a compressor system.
Fig. 9, 10 and 11 illustrate the three possible types of installations.
OILSYS are factory packaged systems including liquid ring vacuum pump using oil for service liquid. For additional details
see chapter 21. The system is complete with oil circulating pump, heat exchanger, oil demister, cyclone for removal of
dust (optional) and other accessories upon request.
Installation is simple and does not require additional details other than those already discussed in the previous chapter.
Suction and discharge piping should be connected to the respective pump flanges. When locating the discharge piping it
should be noted that although the system is fitted with oil demister, there may still be traces of oil fumes carried by the
vented gas. Make sure therefore, that the selected area for vacuum pump discharge is suitable for such purpose.
All other connections, (heat exchanger, draining, etc.) must be properly done. See fig. 48 for location of connections.
7.7 - SERVICE LIQUID (H2O at 15°C) FLOW (in m3/h) FOR VACUUM PUMPS
The listed values are referred to the system with “Once-through” service liquid, handling dry air at 20°C (for more specific
data see the pump’s performance curve).
To reduce the amount of service liquid flow read the information given in chapter 19.
If the pump is handling saturated or condensable gases at relatively high temperatures, there will be condensation inside
the pump. In those cases, the service liquid flow listed below can be increased up to 25% to reduce the discharge
temperature and minimize the danger of pump cavitation at high vacuum.
14 Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS
Tab. 2
PUMP SUCTION PRESSURE (in mbar) PUMP SUCTION PRESSURE (in mbar)
MODEL 33 - 200 > 200 - 600 > 600 MODEL 200 - 600 > 600
TRH 32-4 0,20 0,20 0,16 TRS 32-20
0,34 0,24
TRH 32-20 TRS 32-50
0,36 0,30 0,28
TRH 32-45 TRS 40-55
0,78 0,44
TRH 32-60 TRS 40-80
TRH 40-110 0,90 0,70 0,60 TRS 40-100 0,96 0,57
TRH 40-140 TRS 40-150 1,17 0,72
TRH 40-190 1,00 0,85 0,70 TRS 50-220 2,40 1,29
TRH 50-280 2,40 1,70 0,90 TRS 100-550 2,90 1,74
TRH 50-340 3,00 2,22 1,20 TRS 100-700 3,30 2,10
TRH 50-420 3,60 2,76 1,60 TRS 100-980 9,00 5,40
TRH 80-600 2,50 1,98 1,30 TRS 125-1250 8,70 4,20
TRH 80-750 3,00 2,40 1,60 TRS 125-1550 9,90 4,50
TRH 100-870 TRS 200-1950 18,00 11,40
TRH 100-1260 7,40 5,70 3,80 TRS 200-2500 20,10 11,70
TRH 100-1600 TRS 200-3100 25,80 17,40
TRH 150-2000 12,00 9,60 6,00
TRH 150-2600 13,20 11,10 6,60
TRH 150-3100 16,20 14,10 8,70
7.8 - SERVICE LIQUID FLOW (H2O at 15°C) AND PRESSURE FOR COMPRESSORS SERIES “SA”
Values are applicable when the compressor suction is barometric pressure (1013 mbar) and the gas is air at 20°C.
SA0E3U
SA0G2D
SA0G2G
= 0,90 m3/h
= 1,00 m3/h
= 1,50 m3/h } constant throughout the field work
The minimum pressure inlet of the service liquid should be (according to the use of the compressor):
SA0E3U = 0,90 m3/h at minimum pressure of 2,5 to 3 bar
SA0G2D = 1,00 m3/h at minimum pressure of 2 to 3,5 bar
SA0G2G = 1,50 m3/h at minimum pressure of 2 to 3,5 bar
Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS 15
7.9 - TYPICAL INSTALLATION SCHEMATICS FOR VACUUM PUMPS
1 7
24
27
2
11
20
Fig. 6 19
1 Separator/reservoir
18
6 2 Non return valve
4
14
5 21 3 Shut off valve
3 16 38 27
4 Liquid ring vacuum pump
5 Solenoid valve
6 Electric motor
15 Level switch
16 Filter (y-strainer)
13A 27
13 11
14
9 38
26
16 Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS
7.10 - TYPICAL INSTALLATION SCHEMATICS FOR COMPRESSORS
2
14 23
2
1
20
28
7 19
48 18 Fig. 9
24 6
19 Valve for spare vacuum 4
27
connection 21
20 Vacuum gauge 11
14
3 16 5
21 Anti-cavitation valve 38 27
22 Circulating pump
2
14 23
2
10 1
20
Air or Gas
28
8 7 19 Fig. 11
Liquid-Gas mixture 15
18
48 24 6
25 4
Liquid 27
32 21
22 13A 27
11
14
13 9 38
26
Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS 17
7.11 - CONNECTIONS LOCATION
SEEN LATO
VISTA FROM SEEN FROM
VISTADRIVE
NON DRIVE
OPPOSTO END
COMANDO 5 LATO END
COMANDO V
COLLETTORE
MANIFOLD
7 7
V 5
6
1 8 4
8
2 1 9
9
S 4 S 2 S
(Sul lato opposto)
(Opposite side)
7
TRHE 32-4
TRMX-TRVX 257
TRMB 32 TRMX 327 & 400* TRMB & TRVB 40 / 50 TRVX 650 / 1000 / 1250
V
V V
D A
IN SERVICE
LIQUID
D
A
Z
Z S A* Z S A Z S A S
TRVN
Left rotation
S Z Z S S Z
SEEN FROM
VISTA LATODRIVE END
COMANDO
TRVA 65 COLLETTORI TRVA 65
MANIFOLDS
V V
V
A D
Z A A
Z
S Z D S S S S
18 Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS
VISTA LATO
SEE FROM VISTA
SEE FROM
OPPOSTO COMANDO
NON DRIVE END LATO COMANDO
DRIVE END
5 MANIFOLD
COLLETTORI V
V 5
Fig. 14 - Pomp
series TRS
(for details see
tab. 3)
10 8 4
8
9
9 10
S 4 S S
(Sul lato opposto)
(Opposite side)
Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS 19
Fig. 15 - Pump series SA
V(2) V(1) V(2) V(1)
V(1) – PRESSURE GAUGE
V(2) – VACUUM METER
Z
Z Z
S S S
All drawings are general and schematics (for additional details see the specific pump catalogue).
F F
Fig. 16 - Pump series
TRH – TRS – TRVA 65
with Cartridge Machanical
seals costruction
E E
F F F F
E E E E
20 Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS
7.12 - PUMP ENGINEERING DATA
Tab. 4
with baseplate
Weight ass.ly
Weight ass.ly
(LW) 50 Hz
(B5 design)
(LW) 60 Hz
Noise level
Noise level
Bare pump
Monoblock
Operating Installed
Vibration
Weight,
Level
speed Motor size Electric Motor
PUMP
frame size
MODEL
p
RPM kW
dB(A) dB(A) class kg kg kg 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz
TRHE 32-4 67 (78) 68 (79) 14 19 32 1450 1750 0,55 0,75 80 A 80 B
TRHC 32-20 25 31 41
1,1 1,5 80 B 90 S
TRHE 32-20 18 22,5 34
TRHC 32-45 28 34 44
66 (77) 69 (81) 2900 3500 1,5 2,2 90 S 90 L
TRHE 32-45 21 25,5 37
TRHC 32-60 30 36 47
2,2 3 90 L 100 L
TRHE 32-60 26 31 43
TRHC 40-110 67 79 92
TRHE 40-110 49 61 74
4 5,5 112 M 132 S
TRHC 40-140 79 88 119
65 (77) 68 (79)
TRHE 40-140 V1 67 76 100
TRHC 40-190 87 105 137
5,5 7,5 132 S 132 M
TRHE 40-190 75 93 118 1450 1750
TRHB 50-280 130 146 195 9 132 M
70 (82) 73 (86) 15 160 L
TRHB 50-340 140 170 212 11 160 M
TRHB 50-420 71 (82) 74 (87) 145 178 220 15 18,5 160 L 180 M
TRHC 80-600 220 245 360 22 30 180 L 200 L
76 (89) 79 (92)
TRHC 80-750 240 280 377 200 L 225 S
30 37
TRHE 100-870 412 574 225 M 250 M
TRHE 100-1260 79 (92) 82 (95) 485 652 980 1180 37 45 250 M 280 S
TRHE 100-1600 518 690 45 75 280 S 315 S
---
TRHA 150-2000 83 (98) 84 (99) 1330 1805 75 90 315 MA 315 MB
TRHA 150-2600 V2 1480 2095 740 890 90 110 315 MB 355 S
84 (99) 85 (99)
TRHA 150-3100 1630 2245 110 160 355 S 355 MB
with baseplate
Weight ass.ly
Weight ass.ly
(LW) 50 Hz
(B5 design)
(LW) 60 Hz
Noise level
Noise level
Bare pump
Monoblock
Operating Installed
Vibration
Weight,
Level
RPM kW
dB(A) dB(A) class kg kg kg 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz
TRSC 32-20 19 25 39
1,1 1,5 80 B 90 S
TRSE 32-20 15 19,5 31
69 (81) 70 (82) 2900 3500
TRSC 32-50 20 26 40
1,5 2,2 90 S 90 L
TRSE 32-50 17 21,5 33
TRSC 40-55 54 67 79
2,2 3 100 L 100 L
TRSE 40-55 34 47 59
66 (77) 68 (79)
TRSC 40-80 57 70 82
TRSE 40-80 37 50 62
3 4 100 L 112 M
TRSC 40-100 60 72 85
TRSE 40-100 V1 39 52 64
TRSC 40-150 71 88 96 1450 1750
67 (78) 69 (81) 4 5,5 112 M 132 S
TRSE 40-150 44 57 69
TRSC 50-220 87 104 122
5,5 7,5 132 S 132 M
TRSE 50-220 74 92 109
TRSC 100-550 200 225 327 15 18,5 160 L 180 M
76 (89) 78 (91)
TRSC 100-700 230 255 380 18,5 30 180 M 200 L
TRSB 100-980 78 (91) 80 (93) 250 290 385 30 37 200 L 225 S
TRSE 125-1250 436 596 37 45 250 M 280 S
79 (92) 82 (95) 980 1180
TRSE 125-1550 462 634 45 75 280 S 315 S
TRSA 200-1950 83 (98) 1125 --- 1600 90 315 MB
75 315 MA
TRSA 200-2500 85 (99) V2 1225 1700 740 890 110 355 S
84 (99)
TRSA 200-3100 1325 1800 110 160 355 S 355 MB
Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS 21
Weight ass.ly
Weight ass.ly
50 Hz motor
60 Hz motor
(LW) 50 Hz
(LW) 60 Hz
Noise level
Noise level
Monoblock
Monoblock
Operating Installed
Vibration
Level
speed Motor size Electric Motor
PUMP
frame size
MODEL
p
RPM kW
dB(A) dB(A) class kg Kg 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz
TRMX 253 64 (74) 66 (77) V1 2900 3500 0,75 1,1 80A 80B
TRMB 25-30 65 (75) 68 (79) 17 18 0,75 1,1 80 A 80 B
TRMX 257 64 (74) 66 (77) 27 27
1,5 2,2 90 S 90 L
TRMB 32-50 69 (79) 70 (81) 24 26 2900 3500
TRMB 32-75 37 42
70 (80) 73 (84)
TRMX 327 39 45
3 4 100 L 112 M
TRMB 40-110 66 71
68 (79) 69 (81) V1
TRMX 403 69 ---
TRMB 40-150 76 106
69 (80) 70 (82) 1750 4 5,5 112 M 132 S
TRMX 405 74 --- 1450
TRMB 40-200 103 111
74 (86) 5,5 7,5 132 S 132 M
TRMX 407 72 (84) 110 ---
TRMB 50-300 … 126 --- --- 132 M ---
7,5 ---
TRMX 503 71 (82) … V1 133 --- 1750 132M ---
with baseplate
Weight ass.ly
Weight ass.ly
(LW) 50 Hz
(B5 design)
(LW) 60 Hz
Noise level
Noise level
Bare pump
Monoblock
Operating Installed
Vibration
Weight,
Level
RPM kW
dB(A) dB(A) class Kg Kg Kg 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz
TRVX 257 64 (74) 66 (77) 18 2900 3500 1,5 2,2 90 S 90 L
TRVB 40-110 62
68 (79) 69 (81) 3 4 100 L 112 M
TRVX 403 60
TRVB 40-150 64
69 (80) 70 (82) --- --- 4 5,5 112 M 132 SB
TRVX 405 73
TRVB 40-200 78
72 (85) 74 (86) 5,5 7,5 132 S 132 M
TRVX 407 88
TRVB 50-300 72 (84) … 88 11
TRVX 503 71 (82) … --- 91 --- 1450 1750 ---
7,5 132 M 160 M
TRVA 65-300 133 155 161 11
TRVX 653 70 (82) 97 116 151 11
73 (86)
TRVA 65-450 146 176 201
11 15 160 M 160 L
TRVX 657 71 (82) V1 115 136 170
TRVX 1003 148 173 212 15 22 160 L 180 L
75 (88) 77 (90)
TRVX 1005 161 195 225 18,5 30 180 M
200 L
TRVX 1007 76 (89) 78 (91) 171 205 230 22 30 180 L
TRVX 1253 370 535 30 37 225 M 250 M
TRVX 1255 79 (92) 82 (95) 411 --- 580 980 1180 37 45 250 M 280 S
TRVX 1257 456 603 45 75 280 S 315 S
TRVN 40-70 70 (82) 73 (86) 35 --- 2900 3500 2,2 4 90 L 112 M
TRVN 40-110 50 --- 2900 3500 4 5,5 112M 132 S
72 (85) 74 (86) ---
TRVN 65-250 135 --- 1450 1750 7,5 11 132 M 160 M
TRVN 80-350 76 (89) 78 (91) 296 --- 975 1170 11 15 160 L 180 L
TRVN 80-500 310 --- 975 1170 15 18,5 180 L 200 L
82 (95) 83 (97) ---
TRVN 80-600 340 --- 975 1170 18,5 30 200 L 225 L
22 Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS
with baseplate
Weight ass.ly
(LW) 50 Hz
(LW) 60 Hz
Noise level
Noise level
Bare pump
Operating Installed
Vibration
Weight,
Level
speed Motor size Electric Motor
PUMP
frame size
MODEL
RPM kW
dB(A) dB(A) class kg kg 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz
11 15 160 M 160 M
SA0E3U 67 (79) 69(81) 56 110
15 22 160 M 180 M
11 18,5 160 M 160 L
SA0G2D 70(82) V1 83 135 2900 3500
18,5 37 160 L 200 L
69 (80)
139 15 22 160 M 180 M
SA0G2G 70(82) 87
157 22 45 180 L 225 M
Noise level (sound pressure level measured at 1 m distance, without motor, with pump installed in the system and sound
power level Lw) for pump series TRH, TRM, TRV when operating at 80 mbar and pump series TRS when operating at
250 mbar with motor at 50 Hz operating speed.
The values can change depending on the installed motor. Contact POMPETRAVAINI for further information.
The class of vibration level (values rms mm/s) show the limit values for the continuous working of the pump if properly
installed. For higher values it needs to proceed with maintenance of the pump following the table below.
- Weights are for pumps fitted with Mechanical Seals and in Cast Iron materials (tolerance 10%).
- The assemblies (Monoblock and with Baseplate) are suitable for 50 Hz motors, except where otherwise noted.
Indicated total weights for the assemblies are without motors.
- The installed motor size cover the whole performance curve when operating as vacuum pump.
- The electric motors over the frame size 315 M are not unified.
- For exact weights refer to the specific motor manufacturer data.
In order to have approximate values of the noise level for tha pump-motor assembly the sound power level of the motor
and the pump can be added. The tab. 5 shows some values of the motor noise level. The addition has to be calculated
using the diagram below.
In order to get the total sound power level it is necessary to calculate the difference between the pump and motor noise
level; by that value calculate, from the following diagram, the increment that will have to be added to the higher value of
the power sound level. Ex: motor 80 dB and pump 75 dB, level difference 5 dB, increment 1,2 dB, total power sound level
81,2 dB. Taking into account that the noise level depends on several factors, contact POMPETRAVAINI to know more
accurate values.
The noise level of the pumps is to be understood as lower / equal (≤) to that indicated in the tables because it depends
on the conditions of use. The values can change depending on the installed motor.
Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS 23
Tab. 5
POWER
Noise level Lp (Lw) Noise level Lp (Lw)
ATEX
dB(A) dB(A)
kW
8 poles 6 poles 4 poles 2 poles 8 poles 6 poles 4 poles 2 poles
0,75 55 (63) 50 (58) 48 (56) 59 (67) 54 (62) 48 (56) 53 (61) 64 (72)
1,1 55 (63) 50 (58) 54 (62) 60 (68) 54 (62) 48 (56) 56 (64) 64 (72)
1,5 57 (65) 53 (61) 54 (62) 63 (71) 56 (64) 57 (65) 56 (64) 71 (79)
2,2 57 (65) 55 (61) 55 (63) 63 (71) 60 (68) 59 (67) 57 (65) 71 (79)
3 58 (66) 57 (65) 55 (63) 67 (75) 60 (68) 62 (70) 57 (65) 74 (82)
4 60 (68) 57 (65) 58 (66) 69 (77) 64 (72) 62 (70) 62 (70) 74 (82)
5,5 60 (68) 57 (65) 61 (69) 72 (81) 64 (72) 62 (70) 66 (74) 75 (83)
7,5 60 (68) 63 (71) 61 (69) 72 (81) 64 (72) 66 (74) 69 (77) 77 (85)
11 63 (71) 64 (72) 68 (78) 74 (82) 66 (75) 66 (74) 71 (79) 77 (86)
15 65 (73) 64 (72) 68 (78) 74 (82) 67 (77) 69 (78) 71 (79) 78 (86)
18,5 67 (75) 66 (74) 68 (78) 74 (82) 70 (81) 71 (81) 72 (81) 78 (86)
22 67 (75) 66 (74) 68 (78) 74 (82) 70 (81) 71 (81) 72 (81) 76 (85)
30 69 (80) 68 (78) 73 (84) 82 (93) 70 (81) 72 (83) 72 (82) 78 (88)
37 67 (75) 70 (81) 75 (86) 82 (93) 62 (74) 72 (83) 75 (86) 78 (88)
45 67 (77) 72 (84) 75 (86) 82 (93) 62 (74) 67 (79) 75 (86) 80 (90)
55 67 (77) 72 (84) 78 (86) 84 (98) 63 (77) 67 (79) 77 (88) 80 (91)
75 67 (77) 77 (87) 73 (82) 79 (89) 65 (77) 67 (81) 72 (84) 77 (89)
90 67 (77) 77 (88) 73 (82) 79 (89) 65 (79) 71 (85) 72 (84) 77 (89)
110 73 (85) 77 (88) 79 (92) 84 (97) 65 (79) 72 (86) 73 (86) 77 (91)
132 76 (88) 77 (88) 79 (92) 84 (97) 72 (86) 77 (86) 85 (99)
160 78 (89) 79 (92) 84 (97) 77 (91) 85 (99)
200 79 (92) 84 (97) 77 (91) 85 (99)
250 83 (95) 84 (97)
3,0
2,8
2,6
2,4
2,2
dB increment to add
2,0
1,8
1,6
1,4
1,2
1,0
0,8
0,6
0,4
0,2
0,0
0 1 2 3 4 5 6 7 8 9 10 11 12
dB difference
24 Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS
8 - MOUNTING AND ALIGNMENT INSTRUCTIONS
DANGER!
Danger of collision, harm and crushing! Do not start up the pump without the needful guards on both coupling
and motor. The coupling procedures must be carried out when the pump is stopped, after having activated the
safety procedures to prevent an accidental start-up (also see chapter 2). Operate provided with apposite
protective devices (helmet, glasses, gloves, shoes, etc.).
i Flexible couplings must be properly aligned. Bad alignments will result in coupling failures and damage to pump
and motor bearings.
Assembly instructions for MONOBLOCK design are listed on paragraph 8.3 steps 1, 2, 4, 5, 6.
Assembly instructions for PUMP-MOTOR ON BASEPLATE are listed on paragraph 8.3 steps 7, 1, 8, 5, 9, 10, 11.
For pump driven with V-Belt, please consult POMPETRAVAINI for possible information.
8.2 - ALIGNMENT PROCEDURES FOR MONOBLOCK AND FOR PUMP/MOTOR ASSEMBLY ON BASEPLATE.
The pump/motor assembly is properly aligned by POMPETRAVAINI prior to shipment.
It is however required to verify the alignment prior to the start-up. Misalignment can occur during handling, transportation,
grouting of assembly, etc.
For alignment procedures of MONOBLOCK design see paragraph 8.3 steps 1, 2. 4, 5, 6.
For alignment procedure of BASEPLATE design see paragraph 8.3 steps 7, 1, 8, 5, 9, 10, 11.
PLEASE NOTE: Coupling sizes and permissible coupling tolerances listed in this manual are applicable to the particular
coupling brand installed by POMPETRAVAINI as a standard. For sizes and tolerances of other type
of couplings, follow the instructions given by their respective manufacturer.
NOTE: The following points must be followed with the sequence stated above and depending upon the type of
operation: alignment assembly or alignment verification.
1 - Thoroughly clean motor/pump shaft ends and shaft keys, place the shaft keys in the proper key way slots and fit the
coupling halves in line with the shaft ends. The use of rubber hammers and even pre-heating of the metal half couplings
may be required (see fig. 18).
Lightly tighten the set screws. Verify that both pump and motor shafts rotate freely.
Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS 25
LANTERN
SET SCREW
ALIGNMENT LINES
HALF COUPLING SHAFT
PUMP/MOTOR
SUPPORT
Fig. 18 FOOT
Fig. 19
2 - Insert the perforated metal sheet coupling guard inside the lantern so that the coupling is accessible from one of the
lateral openings. Couple the electric motor to the pump lantern engaging the two coupling halves, hands may reach
the coupling halves through the lateral opening (see fig. 20) tighten the assembly with bolts supplied with the unit
and install the supporting foot, when applicable (see fig. 19). When tightening the connecting screws between
lantern and motor make sure not to force the two half-couplings until they touch each other. If this occurs remove the
motor, axially move the half-coupling on the shaft and repeat the fixing procedure.
SAFETY
COUPLING GUARD OPENING
LANTERN
3 - Applying slight hand pressure to the coupling guard, rotate it so that one opening of the lantern is accessible (see fig. 21).
4 - Rotate by hand the coupling through the lateral opening of the lantern to make sure the pump is free.
5 - With a feeler gauge, check the distance between the two coupling halves. The gap value "S" should be as listed on
table 2 or as given by the coupling manufacturer.
In the event an adjustment is necessary, loosen the set screws on the coupling half and with a screw driver move the
coupling half to attain the gap "S" (see fig. 25). Then tighten the set screw and rotate the rotor by hand to make sure,
once more, that there is no obstruction.
6 - Rotate back the coupling guard by hand through the two openings of the lantern so that both openings are completely
covered. This will complete the alignment verification of the MONOBLOCK design.
7 - Remove the coupling guard and its extension (if there is one) attached to the pump, by removing the two locking
screws (see fig. 22 and 23).
26 Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS
COUPLING GUARD
EXTENSION
COUPLING GUARD
COUPLING GUARD
EXTENSION EXTENSION
8 - Place the electric motor on the baseplate and bring the two coupling halves together with approx. 2 mm gap between
them keeping the motor axially aligned with the pump shaft. In the event the two shaft heights do not align, proper
shimming under the pump or motor feet will be required. Mark the motor and/or pump anchoring bolt holes. Remove
motor and/or pump, drill and tap the holes, clean and mount pump and/or motor in place and lightly tighten the bolts
(see fig. 24).
Fig. 24
9 - With a straight edge ruler check the parallelism of the two coupling halves at several points ,90° from each other (see
fig. 26).
NOTE: Easier and more accurate readings can be attained with instruments such as Dial Indicators (if readily available).
Y1
HALF COUPLING HALF COUPLING
ØA X
SET SCREW
S SET SCREW
Fig. 25 Fig. 26
Y2
Fig. 27
If the maximum value of "X" is higher than that listed in the tab. 6 (for the given coupling size) it will be required to
correct the alignment by using shims under the pump or motor feet.
When the measured values fall within the tolerances, the pump and motor mounting bolts can be tightened.
10 - Angular misalignment can be measured with a caliper. Measure the outside coupling dimension at several points
(see fig. 27).
Find the minimum and maximum width of the coupling, the difference between these two readings "Y" (Y1-Y2) should
Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS 27
no exceed the value listed in tab. 6 for the given coupling size. Should this value be greater it will be necessary to
correct the alignment by shimming the pump and/or motor.
Following this operation it is recommended to check once more the value "X" to make sure that both values are within
the allowed tolerance (see point 9). Make sure that both set screws on the coupling halves are properly secured.
11 - Install the coupling guard and its extension (if applicable) on the pump, secure the two locking bolts.
The gap between motor frame and the guard should not be greater than 2 to 3 mm (see fig. 28).
2 ÷ 3 mm
Fig. 28
9 - ELECTRICAL CONNECTIONS
DANGER!
Electric danger. Electrical connections must be made exclusively by qualified personnel in accordance with the
instructions from the manufacturer of the motor or other electrical components and must adhere to the local
National Electrical Code. Always ground the motor verifying it is properly wired. When the pump is coupled on
baseframe carry out the ground connection also for the baseframe on the preposed position with screw or
through hole marked by the ground connection symbol.
Remove a portion of the paint on the connection point to ensure electrical continuity between the base and the
earthing cable It is advisable to have an electrical switch near the pump for emergency situations.
FOLLOW ALL SAFETY PRECAUTIONS AS LISTED IN CHAPTER 2.
BEFORE DOING ANY WORK TO THE INSTALLATION DISCONNECT ALL POWER SUPPLIES
All electric motors and possible connected accessories must be protected against overloading by means of
i
circuit breakers and/or fuses. Circuit breakers and fuses must be sized in accordance with the full load amperage
appearing on the motor nameplate.
It is recommended that motors over 5.5 kW be wired for Star-Delta start-up, to avoid electrical overloads to the
motor and mechanical overloads to the pump.
It is advisable to have an electrical switch near the pump for emergency situations.
Be sure to replace all safety guards before switching on the electrical power.
Prior to connecting the electrical wiring, turn the pump shaft by hand to make sure that it rotates freely.
Connect the electrical wiring in accordance with local electrical codes and be sure to ground the motor.
Motor connection should be as indicated on the motor tag (frequency and voltage) and as discussed in the motor
instruction manual.
If possible check the direction of rotation before the motor is coupled to the pump but protect the motor shaft to prevent
any accidents. When this is not possible briefly jog the pump to check its direction of rotation(see arrow on pump for
correct rotation). If the direction must be changed 2 of the 3 electrical wire leads must be alternated with each other (at
the terminal box or at the motor starter).
Please be aware that rotation in the wrong direction and/or pump running dry may cause severe pump damage.
Electrical instrumentation such as solenoid valves, level switches, temperature switches, etc. which are supplied with the
pump or systems must be connected and handled in accordance with the instructions supplied by their respective
manufacturers.
28 Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS
10 - CHECK LIST PRIOR TO START-UP
If the installed pump is designated to be used in environments subjected to the application of the ATEX 99/92/CE
directive but does not show the wording “ATEX” on the name plate, and the integrative ATEX manual hasn't
been received or undelivered, it strictly forbidden proceed to start up the pumps but necessary to consult
POMPETRAVAINI for clarifications.
CAUTION!
All questions listed below must have POSITIVE answers prior to proceeding to the pump start-up (the following
list may not be complete for special installations which may require further precautions as the cases dictate)..
- Is this manual entirely read and understood?
i
- Are all the safety protections in order?
- Are the electrical connections properly wired, grounded and protected?
- Is the position of the pump switch-off button evident, accessible and clear?
- The piping system has been flushed of any foreign particles, welding impurities, etc.?
- Have all piping and pump obstruction been removed?
- All connections and piping are leak proof and there are no external forces or moments applied to the piping or pump
flanges?
- Pump and motor are properly lubricated, if required?
- Pump/motor alignment has been checked?
- If mechanical seal requires flushing has this been connected?
- All valves in the installation are in the correct position?
- Has this pump’s direction of rotation been checked by jogging the motor?
- Are pump and installation ready for start-up?
Upon receipt and/or completion of installation, before turning on the power to the electric motor, rotate the pump shaft by
hand to make sure that the pump rotor is free. In the event the shaft does not turn, try to free it up by applying a torque to
the pump coupling with a pipe wrench. To free the rotor of a monoblock style pump (without coupling) introduce a bolt (or
similar tool) at the motor shaft end that has a threaded connection and apply the torque by hand.
In the event the pump does not become free with the above procedures, fill up the pump with a suitable solvent or
lubricating liquid, let it rest for several hours to allow softening of the rust build-up inside the pump, drain the pump and
apply torque to the pump shaft as described above to finally free the rotor.
i The selected solvent or lubricating fluid must be compatible with the pump, seals and gasketing materials.
New pumps from the factory and pumps coming from long term storage are likely impregnated with a rust preventative
liquid; before the start-up, these pumps should be subjected to fresh water rinsing for approximately 15 minutes.
The obtained liquid-water mixture must be collected and, according to the environmental disposal regulations, treated as
special liquid.
Dispose the waste liquids according to the current regulations protecting the environment.
i
CHECK PUMP-MOTOR COUPLING ALIGNMENT!
This must be done prior to the first start-up and before every start-up if pump or motor has been removed from
the installation for maintenance or other reasons. See chapter 8.2.
Prior to starting the pump verify that all auxiliary components are available, ready for use and, where required, they are
in the open position (i.e.: double mechanical seals are pressurized with buffer liquid, cooling liquid to heat exchanger is
open, etc.) and the pump bearings are lubricated.
If the gas and/or service liquid temperatures are in the dangerous levels, it is recommended to insulate the pump, piping
and separator to avoid direct contact with their surface, avoid freezing, thermal shock or loosing heat energy.
NOTE: See chapters 11.4 to 11.6 for OILSYS systems start-up, operation and shut-down.
11.1 - START-UP
(In the following, reference is made to certain ITEM numbers which appear on fig. 6 to 11 of chapters 7 and 20).
Open valve at gas discharge if installed and partially open the valve at the suction side.
When operating the pump as compressor there must be a check valve ITEM 2 fitted at the discharge side.
When pump ITEM 4 is fitted in a partial recovery or total recovery or HYDROSYS systems, as built by POMPETRAVAINI,
it is required to have drain valve ITEM 11 at separator ITEM 1 in the closed position, flow regulating valve ITEM 13 and
overflow valve ITEM 24 in the open positions. Separator overflow valve ITEM 24 should be piped to drain (or collecting
Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS 29
container). Before start-up fill the pump to the shaft centreline, separator and piping of system with service liquid through
pump inlet flange or fill connection ITEM 28. Check all components for leakage.
If the automatic drain valve ITEM 48 is installed, the overflow valve ITEM 24 must be closed after the filling.
CAUTION!
Possible contact with hazardous media, cold or warm, and pump surfaces, cold or warm.
During the following operations it is particularly important to avoid contact and/or inhale of possible spilled liquid
(vapour): therefore all safety precautions must be taken. Operate only provided with apposite protective devices.
Start all accessories (temperature switches, level switches, pressure switches, etc.) open cooling and flushing lines. Start
the pump and open the service liquid valve ITEM 3 (if applicable), soon after start the circulating pump ITEM 22 (if
applicable) and adjust the service liquid flow (see tab. 7).
Gradually open the valve at gas suction side till the required vacuum level is reached.
Check the system for abnormal conditions (see chapters 12 and 16).
If the system is fitted with a circulating pump and/or the service liquid has an excessive pressure the by-pass valve ITEM
13A (if available) or valve ITEM 13 can be adjusted to reduce the service liquid flow to the vacuum pump and/or optimize
the thermodynamic efficiency of the heat exchanger ITEM 9.
NOTE: HYDROSYS systems engineered with multiple pumps are fitted with isolating valves at suction, discharge, and
service liquid lines of each pump. When one or more pumps are not operating it is required to isolate the idle
pump(s) by closing these valves. When the pumps are put back into service the said valves (at suction and
discharge) must be opened.
11.2 - OPERATION
After starting the vacuum pump check the following:
- the vacuum level is as desired or adjust the flow regulating valve to the required vacuum
- flow and temperature of service liquid and/or cooling liquid are as expected (within 25% tolerance)
- motor does not draw more amperage than shown on its nameplate
- the pump-motor assembly does not have abnormal vibrations and noises such as cavitation
- there are no leaks from mechanical seals, joints and flushing or cooling liquid lines
- liquid level in separator is between the minimum and the maximum.
- the operating temperature at full load, does not exceed approximately 85°C
i CAUTION!
Never run the pump dry.
CAUTION!
Possible contact with warm surfaces. Operate only provided with apposite protective devices.
If the gas discharge is not open to the immediate atmosphere but it is piped to other locations, the pump discharge should
be checked for back-pressures that could cause higher power consumption and loss of pump capacity.
First close the service liquid flow and cooling liquid flow (if applicable) then shut down the circulating pump ITEM 22 (if
there is one).
Where possible, gradually decrease the vacuum level to 400/900 mbar in about 10 seconds max or, if compressor,
decrease the discharge pressure. The discharged service liquid from pump ITEM 4 helps producing a slow deceleration
rather than sadden stop.
Turn off the power to motor ITEM 6 and close any accessories and flushing lines.
Make sure the non-return valves ITEM 2, or similar, at suction and discharge lines are leak tight.
Should the system be idle for an extended period of time it is recommended to disconnect the electricity to the motor
panel, drain all liquids from pump, separator and piping. Refer to chapter 6 for storage procedures.
(In the following, reference is made to certain ITEM numbers which are listed in the figures and legend of chapters 12.1
and 19).
Open the valve at the gas discharge, if applicable, and partially close the valve at the suction side.
Close draining valve ITEM 11 and valves for condensate recovery ITEMS 13F and 13L which are on the frame separator
ITEM 1B; open the valve ITEM 13D which is between the circulating pump ITEM 22 and the frame separator ITEM 1B,
30 Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS
then partially open flow regulating valve ITEM 13 between the discharge of circulating pump ITEM 22 and the heat
exchanger ITEM 9 and the by-pass valve ITEM 13A.
If the system is fitted with a separator cyclone ITEM 1D and the adjacent collecting tank ITEM 1E, it is required to close
valves ITEM 11A and 12 and open valve ITEM 13E.
Fill frame separator with service oil through the filling plug ITEM 28. Proper oil level can be seen on sight glass ITEM 7.
Refer to tab. 11 and 12 for the required oil quantity.
Start and/or open applicable accessories (temperature switches, level switches, etc.) and circuitry for cooling and flushing.
Start vacuum pump ITEM 4 and soon after start the circulating pump ITEM 22. Adjust the circulating pump capacity with
valve ITEM 13.
Gradually open the system suction valve till the desired vacuum is achieved. Check the systems for abnormal noises or
vibrations (see chapters 12 and 16).
Adjust by-pass valve ITEM 13A to regulate the oil flow to the vacuum pump or to improve the thermodynamic efficiency
of the heat exchanger.
NOTE: OILSYS systems engineered with multiple pumps are fitted with isolating valves at suction, discharge, and
service liquid lines of each pump. When one or more pumps are not operating it is required to isolate the idle pump(s)
by closing these valves. When the pumps are put back into service the said valves (at suction and discharge) must
be opened.
12 - OPERATING MAINTENANCE
Periodically check the working conditions of the system by means of the instrumentation on the installation (pressure
gauges, vacuum gauges, temperature gauges, ampmeters, etc.) and if the pump is consistently handling the application
for which it was selected.
The operation of the pump should be without abnormal vibrations or noises, if any of these problems is noticed, the pump
should be stopped immediately, search for the cause and make the necessary corrections.
It is good practice to check the pump/motor alignment, the running conditions of the bearings and of the mechanical seals
(see chapter 13) at least once a year, even if no abnormalities have been noticed.
If there is a deterioration of the pump performance, which is not attributable to changes in system demands, the pump
must be stopped and proceed with necessary repairs or replacement.
If the mechanical seals are fitted with external flushing and/or quenching lines their pressures, temperatures and flows
must be checked constantly.
i
If during operation the pump seems to run irregularly, because of noise or vibrations, it is necessary to stop the
unit and investigate the causes of the malfunctioning (see chapter 18).
NEVER ALLOW THE PUMP TO OPERATE IN THE CAVITATION AREA!
Cavitation has the characteristic metallic sound, like if gravel was rotating inside the pump, and it causes also high pump
vibrations. This happens when the pump is running at absolute pressures close to the vapour tension of the service liquid
at the running conditions.
Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS 31
This is a damaging condition for the impellers, port plates and casings. The cavitation causes erosion taking away metal
particles and attacking the surface of the pump components. This is particularly damaging if the pump is handling
corrosive gases, see chapter 16 for suggestions to correct the problem.
Pump series TRH, TRM and TRV are designed for the application of an anti-cavitation valve that should be left open (if
required) see fig. 11 and 12 for the location. This valve should be connected toward the upper part of the discharge
separator so that, depending upon the operating vacuum, the pump can either take air or discharge excessive liquid.
For OILSYS systems the anti-cavitation valve ITEM 13H is piped from pump ITEM 4 to the frame separator ITEM 1B.
During operation it must be avoided to have sudden and frequent variations from high to low vacuum. (e.g.: suddenly
opening the suction valve when the pump is operating at pressures lower than 200 mbar).
This would flood the pump creating high power absorption that would put heavy stress on the motor and coupling.
Particular attention should be put on the quantity of the service liquid flow. The flow will depend upon the type of installation
(see chapter 7), the pump size, and/or the desired temperature rise.
The flow of service water at 15°C, for standard pumps and normal operating conditions at various vacuum levels, is listed
on the specific pump curves and/or on tab. 2 of chapter 7.7.
Usually the temperature rise of service water, when handling dry air at 20 °C, is approximately 4°C.
When condensable (e.g.: vapours) are present in the gas stream the heat load to be removed by the service water will
be higher, therefore the service water temperature rise will be higher.
The service liquid flow and its temperature will affect the pump performance.
Generally the low service liquid flow will decrease the pump capacity, while a high service liquid flow will increase the
absorbed power by flooding the pump (see chapter 19 for information and calculations).
Hard service water will generate limestone build-up inside the pump. The severity of the deposit will vary with the water
temperature. Limestone or mineral deposits on the surface of the internal pump components will cause an increase of
absorbed power, wear of the components and will possibly seize the pump.
It is recommended to monitor the water hardness and, if too high (>18°F), treat the water. If there are no alternatives,
there should be periodical flushing of the pump with a solution that will remove the specific deposits, or the pump must
be periodically disassembled, cleaned of all incrustations and re-assembled.
Systems with total service liquid recovery require periodical change of the service liquid contained in the closed loop. The
heat exchanger must be kept well cleaned of all mineral deposits for an effective thermodynamic heat exchange.
During operation, a closed loop system will lose some of the service liquid, due to evaporation and/or saturation of the
discharged gases. It will be required to periodically make-up fresh liquid into the system.
This operation is not required for those systems that are fitted with a float type automatic make-up valve ITEM 8. This
valve requires water at a pressure of approximately 1 bar.
Systems that handle condensable will experience a rise in the level of the service liquid in the separator. The excessive
liquid will be overflowed through the overflow valve or connection.
If the specific gravity of the condensable is higher than that of the service liquid, the condensable must be discharged
through the separator drain valve ITEM 11, preferably with system not running.
32 Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS
To replace the oil demister filter, simply disconnect the oil 1C 14 13G 1D 1B
scavenger line, remove the cover ITEM 1C, remove the used
filter element.
13 - BEARINGS MAINTENANCE
DANGER!
Danger due to collision, crushing or harm. Wait for the complete pump stopping before handling the unit. If the
pump still contains some fluid it may suddenly start to rotate once again. Take precautionary measures by
draining the pump or closing the pipes by mean of a valve. Possible contact with high temperature surfaces,
wait for the pump cooling. Maintenance must be absolutely carried out when the pump is at a standstill,
disconnecting the power supply and any other connection. Please make sure that the power supply is restored
only by the operator making the maintenance. It is necessary the presence of at least two operators and a
foreman must be aware there is a maintenance in progress.
Operate only provided with apposite protective devices.
FOLLOW THE SAFETY STANDARDS LISTED IN CHAPTER 2.
During assembly the bearings are already lubricated with high quality grease with working temperature limits -30°C
+140°C (for pumps type TRHA 150 and TRSA 200 the working temperature limits are -20°C +180°C).
The bearings must be lubricated every 2000/2500 hours, or at least once in a year, injecting a moderate quantity of good
quality lubricating grease (about 1/5th of the quantity shown in table 8). Any leakage of old grease must be removed. We
recommend replacing the bearings every 15000 hours or when replacing the mechanical seals (for replacement see the
"Disassembly and assembly instructions").
Dispose the waste grease according to the current regulations protecting the environment.
The sealed pre-greased never need lubrication, but must anyway controlled after 2000/2500 working hours.
Bearing temperature should not exceed the 85°C during normal working conditions and normal environments.
Bearings can overheat for reasons such as too much grease, misalignment of flexible coupling, wrong bearings, excessive
vibrations, bearing wear. See tab. 8 for bearing numbers and type used for each pump.
Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS 33
14 - PACKED STUFFING BOXES
DANGER!
Danger due to collision, crushing or abrasions. Possible contact with hazardous fluids, cold or warm. Wait for
the complete pump stopping before handling the unit. If the pump still contains some fluid it may suddenly start
to rotate once again. Take precautionary measures by draining the pump or closing the pipes by mean of a
valve. Remove protections only in case of maintenance. Operate only provided with apposite protective devices.
Pumps fitted with packed stuffing boxes require packing flushing either from an external source or directly from the
pumped media through pump internal passages.
This liquid is necessary to remove the friction heat generated between the shaft and the packing.
The dripping quantity is a function of the pump size and of the pressure in the stuffing box housing.
In any event the liquid drops coming out of the stuffing box should not exceed a temperature of 60 - 70°C in relation to
handling a liquid at ambient temperature.
15 – MECHANICAL SEALS
DANGER!
Danger due to collision, crushing or abrasions. Possible contact with hazardous fluids, cold or warm. Wait for
the complete pump stopping before handling the unit. If the pump still contains some fluid it may suddenly start
to rotate once again. Take precautionary measures by draining the pump or closing the pipes by mean of a
valve. Remove protections only in case of maintenance. Operate only provided with apposite protective devices.
Purpose of mechanical seals is to retain handled product inside the pump in the area where the shaft exits the pump
casing. Mechanical Seals can be of many different materials, types and configurations (see fig. 32-33-34 for some
examples).
To assure maximum reliability and safe operation Pompetravaini evaluates seal choices at time of pump selection in
connection with customer’s requirements, application and liquid details.
In the case of self-lubricated single mechanical seals (API Plan 01, 02 or 11, see fig. 32) flushing and /or pressure system
are not required, pump has been engineered to provide proper seal lubrication with pump operating pressure.
In the event the application requires increased safety margin against possibilities of product leaking through a single type
mechanical seal, it is possible to install two mechanical seals working simultaneously thus creating a safety barrier from
the pumped liquid.
There are two possible types of double mechanical seals: Back-to-Back (also known as “Opposite” type) API Plan 54,
see fig. 33 and in Series (also known as “Tandem” type) API Plan 52, see fig. 34.
Double mechanical seals Back-to-Back are generally selected where pumped liquid is absolutely not allowed to leak from
the pump. Double mechanical seals in Series are chosen where the pumped liquid may escape the pump toward the
pump exterior but it is controlled and contained in the closed seal loop but never to escape to the atmosphere.
Double mechanical seal installations require a flushing (buffer) liquid from an external source that is compatible with the
pumped product as well as the working conditions. Flushing liquid system is such as to guarantee adequate buffer liquid
pressure and temperature to the mechanical seals: seal flushing system with proper instrumentation and controls is of
paramount importance for a successful pump installation, it must be installed by qualified personnel familiar with every
details of the application and with system set-up.
34 Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS
All flushing systems MUST use tubing with diameters equal or larger than the connections provided on the pump, buffer
liquid must be compatible with the pumped product. Pressure on the buffer liquid should always be constant and/or high
enough to cover the entire pump performance.
In the case of ‘once through’ seal flushing (buffer liquid not recycled), it is very important the regulation and control of
pressure in the seal housing. In the double seal case it is recommended to adjust the buffer liquid pressure with a flow
regulating valve installed after the seal housing while reading pressure on a gauge installed between the seal housing
and the valve. Avoid controlling buffer liquid pressure before the seal housing, reading the pressure before the seal
housing is NOT recommended as it could lead to wrong conclusions which could be cause for serious damages.
With an adequate seal tank in the system (see fig. 37) a closed loop seal flushing, containing possible leakages is
provided. Adequate controls and/or instrumentation will provide pressure and liquid level controls in the tank to indicate
the conditions of the sealing system. Increase of liquid level (or pressure) is indication of product leaking through the
pump seal. Decrease of liquid level (or pressure) is indication of buffer liquid leaking inside the pump or to the atmosphere
through the outside seal, in which case the leakage is also visible.
The liquid to be used in the seal tank must offer full compatibility with the pumped liquid in the event the seal at pump
side will leak, (for example when the two liquids will mix there must not be any dangerous chemical reactions) as well the
liquid must offer good lubricating characteristics and good heat dissipation. Some good examples of suitable buffer liquids
are water, vaseline oils or vegetable oils.
Pressure in the seal tank is often kept with pressurized Ozone or Nitrogen bottle. Cooling of the buffer liquid in the loop
(picks up friction heat from the seal faces) is achieved with fresh liquid through the cooling coil fitted inside the seal tank.
Seal tank is provided with Inlet & Outlet connections for sealing liquid. DO NOT reverse these two connections; the liquid
circulates by natural heat convection (warm liquid moves upward and cold liquid downward), reversing the connections
would prevent the start of such natural phenomenon. The buffer liquid outlet connection going to pump seal housing is at
bottom of tank while the return connection is approximately at the middle of the tank.
Checking of proper liquid circulation is done while pump is in service; the piping at seal housing connection should be
colder by 3 to 5°C than the outlet tubing exiting the seal housing going to the tank. If this is not the case simply change
the tubing on the seal housing (connect tubing from inlet to the outlet and vice versa) do not change the connections on
the tank. Sometimes this adjustment is required because the rotation of the mechanical seal (and at times peculiar seal
design) generates an hydraulic pressure that could be opposite and higher than the natural. Only in ‘field’ check one can
be assured of the correct liquid circulation. Monitoring the pressure in the seal tank with pressure switches or pressure
gauges and/or controlling the liquid level in the tank allow the verification of possible seal leakages and prompt corrective
actions can be taken when required.
Use good quality gauges to monitor the pressure, with good dial and scale graduation adequate for good reading in the
anticipated pressure range. As a minimum use liquid filled gauges with dial size of minimum 60 mm and 2.5 accuracy.
Additional data and information may be requested from Pompetravaini or its local representative if required.
i Incorrect pressure of seal housing could cause severe damage to the rotating parts. To minimize seal system
malfunctions avoid pressure fluctuations in the seal loop as well as in the pump operating pressure.
when pump is in stand-by mode. Flushing liquid therefore must
be at least 0.5 bar over the maximum pump discharge pressure
throughout its performance.
A lower pressure, even if for a moment, will cause the
stationary part of internal seal to come out of its seat and the
pumped liquid will mix with the flushing liquid due to the higher
pressure inside the pump, see fig. 31.
In the case of double seals in series (Tandem) the pressure of
the flushing liquid should be as low as possible but high enough
to provide good flow in the circuit. High pressures (over 0.3 bar
over the atmospheric pressure) may push the stationary seat
of mechanical seal at product side (closer to pump impeller), out of its seat (especially when pump is at rest without
pressure), therefore flushing liquid would mix with the product inside the pump following seal system damage.
i Incorrect pressure in sealing system is the most common cause for seal system failure, therefore a continued
monitoring with prompt corrective actions are necessary.
Required flow and pressure for buffer liquid are listed in tab. 7 and/or contact Pompetravaini and/or seal supplier.
Standard mechanical seals supplied with our pumps meet ISO 3069/UNI EN 12756 standards, see pump “Disassembly
and Assembly Instructions” for overall dimensions. Special or non-standard seals can be installed after proper evaluation
by our technical department. Mechanical seals do not require maintenance until losses of liquid are visible (for seal
replacement see “Disassembly and Assembly Instructions”). Losses of few drops of liquid in several minutes is normally
considered acceptable and it is not an indication of seal failure.
Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS 35
Seal leakage or even seal failure should be properly corrected considering the impact on environment, toxicity and safety
issues.
CAUTION!
Pay attention to possible leakage of pumped liquid from mechanical seal which, by its characteristics, could be
harmful to the environment.
Mechanical seals should NEVER run dry, without flushing liquid (internal or external). This could cause severe damage
to the seal faces, O-Rings and elastomer.
Mechanical seals are wear parts: the actual mechanical seal life depends on the severity of the duty load.
It is recommended to check the wear of seal faces every 4000 working hours. This is an acceptable normal life span for
mechanical seals. Exceeding this life span can lead to losses due to wear and tear and will require seal replacement.
In case a mechanical seal is replaced, the condition of shaft sleeve (if present) must be checked: if the sleeve surface is
damaged, or in case of doubt, it is recommended to replace also the shaft sleeve together with the mechanical seals.
36 Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS
Pressure at least 0,5 bar over the
working pressure
Pump working pressure Pump working pressure
Fig. 32 Fig. 33
Typical example of self-flushed SINGLE Typical example of DOUBLE BACK-TO-BACK mechanical seal
mechanical seal - API Plan 01, 02 or 11 with liquid from an outside source – API Plan 54
Handled liquid
Pump working pressure
Fig. 34
Typical example of DOUBLE mechanical seals in SERIES with
buffer liquid from an outside source – API Plan 52
BussolaNon-contact safety
di sicurezza senza bushing
contatto Max pressure
Pressione 0,3 bardiover
max. superiore 0,3 bar
Sfiato alla pressione atmosferica
atmospheric pressure
Vent
Drenaggio
Drain Tenuta aContact auxiliary
labbro strisciante seal
Fig. 35
Fig. 36
Example of SINGLE mechanical seal with QUENCH
Example of SINGLE mechanical seal with QUENCH
API Plan 01/61
API Plan 01/62
(NOTE.: Continuous flushing is not possible)
Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS 37
Minimum level sensor
Tank fill plug
Gauge
Fig. 37
Typical example of seal tank,
Pressure switch pressurized, cooling liquid and
Outlet cooling liquid instrumentation. (Instrument
location can vary)
Temperature gauge
Liquid level (must be higher than
return liquid level from pump)
Tank pressure plug
NOTE: Tank installation
Drain must be at least 1 m
above the rotating
Inlet liquid (coming back from
pump shaft
mechanical seals)
Outlet liquid going to
Inlet cooling liquid mechanical seals
38 Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS
Tab. 8
BEARING MECHANICAL SEAL
PUMP MODEL Grease Quantity Diameter
Quantity Type Quantity
each bearing - gr. mm
TRHE 32-4 1 6302.2RS 1 16
TRHC & TRSC 32
2 6304.2RS 22
TRHE 32-20/45/60 - TRSE 32 2
TRHE 40-110 - TRSE 40 2 6305.2RS 28
1 6205.2RS
TRMB 25-30 22
1 6204.2RS
1 6305.2RS
TRMX 257 – TRMB 32-50
1 6205.2RS 24
TRVX 257 2 6007.2Z
1 6306.2RS
TRMB 32-75 28
1 6206.2RS
1 6306-2ZC3
TRMX 327 43
1 6206-2ZC3
1 6208.2Z
TRMB 40-110 – 3 kW
1 6206.2Z
1 6208.2Z
TRMB 40-110 – 4 kW
1 6306.2Z
1 6208.2Z --- 35
TRMB 40-150 – 4 kW
1 6306.2Z 1
1 6210.2ZC3
TRMB 40-150 – 5.5 kW
1 6208.2ZC3
TRVB 40-110 - TRVB 40-150 2 6208.2Z
1 6210.2ZC3
TRMB 40-200 – 5.5 kW
1 6208.2ZC3
TRMB 40-200 – 7.5 kW 1 6210.2ZC3
TRMB 50-300 – 7.5 kW 1 6208.2ZC3 45
1 6210.2Z
TRVB 40-200 - TRVB 50-300
1 6208.2Z
TRMX 403 & 405 6306-2ZC3
TRMX 407 2 6308-2ZC3 55
TRVX 403 & 405 6208-2Z 45
1 6208-2Z
TRVX 407 55
1 6210-2Z
TRHC & TRSC 40 - TRHE 40-140/190
2 6306.2RS 35
TRSC & TRSE 50
TRHB 50 - TRVA 50 - TRVA 65 2 6308 60 43
TRSB 100 - TRSC 100 2 6310 90 55
1 6310
TRHC 80 110
1 21310E
1 3210B 70
TRHC 80/1
1 6310-C3 80
1 6308-C3
TRVX 650 40 2 45
1 3207B
1 3210B 70
TRVX 1000 55
1 6310-C3 55
1 21313E 100
TRVX 1250
1 22213E 140
75
1 6314
TRHE 100 - TRSE 125 280
1 NU314E
2 7320B/UAM
TRHA 150 - TRSA 200 750 110
1 22320E-C3
TRVN 40-70 2 6307-2RS --- 1 32
TRVN 40-70/Z4 3 6308-2RS --- 1 32
TRVN 40-110 2 6308-2RS --- 1 35
6310-2Z
TRVN 65 2 --- 1 50
6311-2Z
6217-2RS
TRVN 80 2 --- 1 80
6317-2RS
NOTE: The supplied data are for pumps in STANDARD construction. For special construction (e.g. /1X-1Y-1W and belt
drive) please contact POMPETRAVAINI.
Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS 39
16 - TROUBLE SHOOTING: PROBLEMS, CAUSES AND SOLUTIONS
Consult the following tab. 9 when problems are experienced, if solutions are not found in this chart or should there be any
doubts, do not hesitate to contact POMPETRAVAINI or your local representative.
CAUSES SOLUTIONS
Check the voltage, the frequency, motor type, power consumption,
1 Defective motor or wired wrong
rotation, wiring connections, phase consistency
2 Leakage in suction piping Repair piping; check valves for leakage
Lower the service liquid temperature;
3 Service liquid high temperature check the level of the service liquid; adjust the cooling liquid flow;
adjust the radiator thermostat to lower temperature setting
4 Low service liquid flow Increase the service liquid flow
5 Coupling misalignment Re-align the coupling and the pump/motor assembly (see cap. 7)
6 Faulty bearing Replace the bearing(see “Disassembly & Assembly Instructions”)
Open the anti-cavitation valve or set the relief valve to a lower
7 Cavitation
vacuum (see tab. 3)
8 High service liquid flow Reduce the service liquid flow; adjust the by-pass valve
Check the discharge line for obstructions or high friction losses;
9 High back pressure
reduce the back-pressure to maximum 0.1 bar
Verify that the base surface is level and that all pump feet are
10 Wrong pump/motor assembly
resting on the surface, add spacers if required (see chapter 11)
Change the mechanical seal (see “Disassembly & Assembly
11 Mechanical seal failure
Instructions”)
12 Wrong pump mounting Remount the pump (see chapter 7)
13 Piping weight resting on pump Support the piping with hangers or other means (see chapter 11)
14 Inadequate seal lubrication Check flushing liquid temperature, flow and pressure
15 Mineral deposits from hard water Clean the pump
Disassemble the pump to remove the foreign objects (see
16 Foreign particles in pump
“Disassembly & Assembly Instructions”)
Open the vacuum regulating valve and/or the anti-cavitation valve
17 Low suction pressure
(see tab. 3)
18 Wrong pump rotation Reverse the rotation (see chapter 8)
Replace the defective gaskets (see the “Disassembly & Assembly
19 Bad gaskets
Instructions”)
Check the electrical connections (connectors, fuses, breakers)
20 Wrong motor connections
and the power supply line (see chapter 8)
Disassemble and repair the pump (see ”Disassembly & Assembly
21 Pump seized
Instructions”)
22 Pump undersized Select a pump with higher capacity
Disassemble and repair the pump (see “Disassembly & Assembly
23 Pump worn-out
Instructions”)
Reduce the liquid flow through the pump suction; install a
24 Excessive liquid flow through suction line
centrifugal separator (cyclone) before the pump
25 Instrumentation out of calibration Check the working characteristics, replace if required
40 Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS
17 - REPAIRING AND REMOVING PUMP FROM THE INSTALLATION
Should there be the need for pump repair a knowledge of the specific “Disassembly and Assembly Instructions” is
required.
DANGER!
Danger due to collision, crushing or harm. Wait for the complete pump stopping before handling the unit. If the
pump still contains some fluid it may suddenly start to rotate once again. Take precautionary measures by
draining the pump or closing the pipes by mean of a valve. Possible contact with high temperature surfaces,
wait for the pump cooling. Maintenance must be absolutely carried out when the pump is at a standstill,
disconnecting the power supply and any other connection. Please make sure that the power supply is restored
only by the operator making the maintenance. It is necessary the presence of at least two operators and a
foreman must be aware there is a maintenance in progress.
Operate only provided with apposite protective devices.
FOLLOW THE SAFETY STANDARDS LISTED IN CHAPTER 2.
To remove the pump and the motor from the installation proceed as follows:
- remove bolts from pump suction and discharge flanges
- remove the coupling guard
- remove the spacer of the coupling, if there is one
- if required, remove the motor anchor bolts on the baseplate, for base mounted assembly, or the bolts on the adapter
flange in the case of monoblock design
- remove the pump anchor bolts on the baseplate
- remove the pump from the installation. Avoid damaging other system components.
Before returning the pump to POMPETRAVAINI or an authorized service decontaminate the pump and ask for the
“handled media” examination form.
In case of pump removal from the installation dispose the unit by following the current regulations and the right
measures to protect the environment.
After pump repairs, re-install following the steps from "Assembly and Alignment" procedures and after (see the applicable
chapters).
18 - SPARE PARTS
When ordering the pump it is good practice to also order the necessary spare parts, especially when there are no stand-
by pumps in the installation. This will minimize unnecessary down times in the event of pump failure or routine
maintenance.
It is therefore, recommended to stock the following spare parts for each pump size:
1 Impeller set
1 Complete shaft assembly
1 Bearing set
1 Mechanical seal set (or packing set)
1 Gasket sets
1 Radial seal ring set
1 Bearing spacer set
1 Coupling rubber insert set
For better parts management, the VDMA 24296 standards suggest to stock the number of parts as a function of the
number of pumps being used in the plant.
On the pump nameplate are printed pump model, year of manufacture and pump serial number. When ordering spare
parts always provide this information. Pump type, parts item number (VDMA) and description as per the pump sectional
drawing and parts list is useful information that helps to supply correct spare parts for your pump.
We recommend the use of original spares: in case this is not respected, POMPETRAVAINI declines any responsibility
for possible damages and not correct running caused by not original spare parts.
Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS 41
19 - ENGINEERING DATA
19.1 - INFLUENCE OF SERVICE LIQUID TEMPERATURE, SPECIFIC GRAVITY AND VISCOSITY ON PUMP
PERFORMANCE
The performance of liquid ring vacuum pumps is based on the use of water at 15°C as service liquid. With water at
different temperatures the pump capacity and the maximum attainable vacuum level will vary in function of the type of
pump, as illustrated by the curve sets of fig. 38 and 39.
EXAMPLE: Pressure = 60 mbar - Water temperature = 24°C - Pump series TRH - Capacity (15°C water) = 120 m3/h
From curves of fig. 39 we find the correcting factor of 0,80, therefore the actual capacity for the pump at the
given conditions will be: 120 x 0,80 = 96 m3/h.
The maximum suction pressure before incurring cavitation will be approximately 45 mbar.
Regarding the performance variation due to changes of specific gravity and viscosity, it can be assumed a proportional
variation in power consumption however, the changes in capacity at different pressures must be analysed case by case.
Please refer the conditions to POMPETRAVAINI when these corrections are needed.
PRESSIONEABSOLUTE PRESSURE
ASSOLUTA - Absolute pressure
20 30 50 100 150 200 300 500 700 Torr
1,4
12°C 10°C
1,3
1,2
Fig. 38
14°C
Single stage pump 1,1 1,1
RAPPORTO DI PORTATA - Temperature factor
0,8 0,8
18°C
CAPACITY FACTOR
0,7 0,7
20°C
22°C
0,6 0,6
24°C
26°C
0,5 28°C 0,5
30°C
32°C
35°C
0,4 40°C 0,4
45°C 50°C
TEMPERATURA DELL'ACQUA DI ESERCIZIO
0,3 SERVICE
Service waterLIQUID TEMPERATURE
temperature
0,3
0,2 0,2
25 30 40 50 70 100 150 200 300 500 700 1000 mbar
PRESSIONE ASSOLUTA - Absolute pressure
ABSOLUTE PRESSURE
MAXIMUM OPERATING
LIMITE CAPACITA' PRESSURE
DI ASPIRAZIONE - Lowest allowable suction pressure
PRESSIONEABSOLUTE PRESSURE
ASSOLUTA - Absolute pressure
20 30 50 100 150 200 300 500 700 Torr
1,4
10°C
1,3
1,2
Fig. 39 12°C
RAPPORTO DI PORTATA - Temperature factor
0,2 0,2
25 30 40 50 70 100 150 200 300 500 700 1000 mbar
PRESSIONE ASSOLUTA - Absolute pressure
ABSOLUTE PRESSURE
LIMITE CAPACITA'
MAXIMUM OPERATINGDI ASPIRAZIONE
PRESSURE - Lowest allowable suction pressure
42 Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS
19.2 - SERVICE LIQUID TEMPERATURE CHANGE ACROSS THE PUMP
The service liquid of a liquid ring pump absorbs total heat Q T as follows:
QT (kJ/h) = Qc + QK + QR
Where:
QC = 0,9 x P x 3600 = Isothermal compression heat
QK = mV x r = Condensation heat
QR = mg x cp x Ta = Cooling heat (Generally negligible, ignored in calculation of Q T)
Once the QT is known it is possible to calculate the differential temperature T of the pump service liquid:
QT
T =
QA cp
Where:
QT = total heat load before calculated in kJ/h
QA = pump service liquid flow in m3/h
= service liquid density in kg/m3 (water = 1000)
cP = service liquid specific heat in kJ/kg x K
(Some values for cP: Water = 4,2 - Air = 1,0 - Water Vapour = 1,84)
NOTE: It can be assumed that the discharge gas and service liquid have same temperature.
(
QF m 3 h = ) Q A T
T2 − T1 + T ~T2+T
where:
QF = Fresh make-up flow from outside source in m3/h
QA = Total service liquid flow required for the operating
conditions in m3/h QF
T2+T
T = Service liquid temperature rise (see chapter 19.2)
T2 = Service liquid temperature to pump TG
T1 = Temperature of make-up liquid Recirculation
line
The fig. 40 indicates a generic schematic of a liquid ring kW
vacuum pump in a partial recovery system.
By closing the recirculation line the system would become a QA-QF
“once through” installation where all the service liquid is
drained, therefore: QF,T1
QA,T2
QA = QF and T2 = T1 Fig. 40
Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS 43
19.4 - UNIT CONVERSION TABLE
Vaporization heat
Saturated water
temperature
Absolute pressure Vacuum
44 Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS
20 - ENGINEERING DATA FOR “HYDROSYS” SYSTEMS
WORKING PRINCIPLE
The HYDROSYS packages main components are: a liquid ring vacuum pump ITEM 4 from series TRH, TRS, TRM, TRV,
an air/liquid separator reservoir ITEM 1, a heat exchanger ITEM 9, all mounted on a common and compact frame ITEM
30. When working, the vacuum pump discharges from the discharge port the gas handled with a portion of the liquid from
the pump internal liquid ring. This liquid must be continuously returned to the pump.
The gas/liquid mixture is separated in a cylindrical tank
(separator), the gas is vented through the top mounted (General schematic drawings)
discharge flange of the separator and the liquid is collected at 1
the bottom of the separator ready to be returned to the 28
vacuum pump.
During the suction and compression cycle of the vacuum 8
pump, all the energy is transformed into heat energy and 6 4
almost all of it is absorbed by the service liquid. Therefore the 7
liquid must be cooled prior to be returned to the pump, either
with a heat exchanger (total recovery system) or with the
addition of cool make-up liquid (partial recovery system).
The TOTAL RECOVERY system (see fig. 41 and legend on
following page) does not require an appreciable flow of make- 24
up from an external source but only the necessary amount to
compensate for the liquid lost due to evaporation, with the
discharged gases.
The heat exchanger sizing should be based on using a
minimum amount of cooling liquid (usually water) to keep the
service liquid at the ideal temperature for the best efficiency 30 9 33 13 22 27 11
of the vacuum pump. Remember, the higher the temperature
of the service liquid the higher the losses in pump capacity Fig. 41 - TOTAL RECOVERY system
and maximum vacuum, see chapter 19.
This system is particular suitable where the service liquid and
the condensed gases cannot be discharged to the
environment, either for pollution reasons or because the
fluids are too valuable.
The PARTIAL RECOVERY system (see fig. 42 and legend
on following page) requires a constant flow of cold make-up
liquid from an external source. This liquid must be of the same
nature as the service liquid being used by the pump. The
mixture of the make-up and the service liquid being
discharged by the pump, will have a constant temperature 13
when enters the vacuum pump service liquid connection.
The same amount of service liquid taken from the outside Fig. 42 - PARTIAL RECOVERY system
source must be overflowed through the separator overflow
connection situated at the pump shaft centreline.
This system is utilized in many applications for conditions where there is intermittent use, or low vacuum levels, or there
is no danger of pollution and the liquid can easily be drained.
Furthermore this may prove to be the only alternative to the total recovery system for those installations where the cooling
liquid is not available or it is too warm.
Numerous accessories are available to meet the customers' requests and suitable for the installation, process and
maintenance.
For materials of construction and some engineering data see tab. 10 and 11.
Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS 45
SOME EXAMPLES OF “HYDROSYS” SYSTEMS (General schematic drawings)
35 14 23
2 1A
13
20
17 10
32
15
33 9 13
48 LEGEND
1 Separator reservoir
1A Separator reservoir with removable lid
2 Check valve
4 Vacuum pump
34 33 26 13A
6 Electric motor
7 Level gauge
Fig. 43 - Accessories upon request 8 Float valve
9 Heat exchanger
10 Solenoid valve liquid make-up
30 6 9 4 13 12 11 Drain valve
8 12 Isolating valve
13 Service liquid flow regulating valve
28 13A By-pass valve
14 Pressure gauge
1
15 Level switch
17 Air ejector
20 Vacuum gauge
22 Circulating pump
23 Pressure relief valve
24 Overflow valve
24 25 Solenoid valve for overflow
7 26 Solenoid valve for cooling liquid
27 Thermometer
27 28 Fill connection
30 Frame
12 32 By-pass piping
6 13 4 22 33 Connection cooling lines
34 Temperature switch
Fig. 45 - Duplex system, total recovery (Top view) 35 Vacuum relief valve
48 Automatic drain valve (for systems used as
Compressor only)
Tab. 11 - GENERAL AND NOT BINDING ENGINEERING DETAILS FOR “HYDROSYS” & “OILSYS” SYSTEMS
Dry weight without Service Liquid Service Oil
PACKAGE Pump and Motor Quantity Quantity
Motor size
SERIES kg litres litres
HYDROSYS OILSYS HYDROSYS OILSYS
HYDROSYS 3 kW
2 80 180 12 40
OILSYS 2 poles / 50 Hz
HYDROSYS 4 kW
3 90 220 35 98
OILSYS 4 poles / 50 Hz
HYDROSYS 7,5 kW
4 120 280 50 110
OILSYS 4 poles / 50 Hz
HYDROSYS 15 kW
5 150 350 80 145
OILSYS 4 poles / 50 Hz
HYDROSYS 30 kW
6 230 500 135 186
OILSYS 4 poles / 50 Hz
HYDROSYS 45 kW
7 500 750 320 360
OILSYS 6 poles / 50 Hz
46 Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS
21 - ENGINEERING DATA FOR “OILSYS” SYSTEMS
WORKING PRINCIPLE
OILSYS packages main components are: a liquid ring vacuum pump ITEM 4 from series TRH, TRS, TRM, TRV, an
air/liquid separator reservoir ITEM 1B which is also a self-contained frame, a heat exchanger ITEM 9 and an oil demister
filter ITEM 1C.
Turbine type mineral oil, or equal (see tab. 12), is used for service Tab. 12 - SUGGESTED OILS
liquid. The characteristics of the chosen oil are such that at MANUFACTURER TYPE
pressures below 100 mbar, the pump capacity is greater than AGIP OTE 32
what would be when using water, and higher vacuum levels are ESSO TERESSO 32
attainable. When working, the vacuum pump discharges the gas LUBRA OLNEO 32
handled with a portion of the liquid in the special frame ITEM 1B MOBIL DTE LIGHT 32
that acts as separator of gas from the oil and let settle any SHELL TURBO OIL 32
condensable or particles coming through the pump suction
TOTAL PRESLIA 32
flange. The circulator pump ITEM 22 pumps the oil back to the
vacuum pump after it has been through the heat exchanger ITEM
9 and cooled at about 60/80°C. The gas is vented after being cleaned of all oil with the special oil demister element; a
pressure gauge ITEM 14 on the filter housing ITEM 1C gives indication of the degree of dirt contained by the filter element.
Special inspection openings ITEMS 43 are easily accessible for maintenance and cleaning of the frame separator.
Contrary to rotary vane vacuum pumps, there are no moving parts that come in contact with each other, therefore there
is no need for lubrication of the pump internals; these are very robust and reliable pump packages which offer extended
operating life even when handling condensable gases.
See tab. 13 for materials of construction and tab. 11 in chapter 20 for some engineering data.
6 13 20 2 13G 4 14 1C 28
(General schematic drawings)
13L 9
13
13A 1B 9 13 13D 22
43 11 13F 13A 1B 13H 27 22 13D Fig. 47 - Option with Shell & Tube heat exchanger
Fig. 46 - STANDARD design
LEGEND
1B - Frame separator 11 - Drain valve 13G - Oil drain valve
1C - Filter housing 11A - Drain valve 13H - Ant cavitation valve
1D - Cyclone separator 12 - Overflow valve 13L - Condensate drain valve
1E - Collecting tank 13 - Flow regulating valve 14 - Pressure gauge
2 - Check valve 13A - By-pass valve 20 - Vacuum gauge
4 - Vacuum pump 13C - By-pass valve 22 - Circulating pump
6 - Electric motor 13D - Isolating valve 27 - Thermometer
7 - Level gauge 13E - Isolating valve 28 - Fill connection
9 - Heat exchanger 13F - Condensate drain valve 43 - Inspection openings
Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS 47
21.1 – LIFTING AND MOVING OF OILSYS SYSTEMS
DANGER!
Danger due to overturning or crushing. The Oilsys systems must ALWAYS be handled and lifted and moved in
horizontal position and without any oil in the tank.
For a safe lifting it is necessary use only ropes or belts positioned on metal bars that were previously inserted
in the lifting holes present on the base (see fig. 48) and handle it carefully to avoid damages to the system or
harm to the operators.
The bars diameter MUST NOT BE MORE than 5 mm smaller than the diameter of the lifting holes on the base.
During handling always use appropriate protective devices.
The bars diameter must not be more than 5 mm smaller than the diameter of the lifting holes on the base.
The lifting bars, after having been inserted in the lifting holes, must be blocked at both ends to avoid the withdraw of the
rope or of the bars itself.
For the lifting with ropes or belts use only a balance beam to have a traction upright to the ground.
NOTE: The eyebolts intended for the lifting of a single component of the system MUST NOT be used to lift the entire
pump system.
Fig. 48
48 Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS
(blank page)
Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS 49
(blank page)
50 Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS
PRINTED IN ITALY
Continuing research of POMPETRAVAINI results in product improvements: therefore, any specification may subject to change without notice.
I Il Presidente
e responsabile tecnico
GB The President
and Technical Manager
F Le Président
et le Directeur Technique
D Der Geschäftsführer
und Technische Manager
E El presidente
y el director técnico
NL De algemeen
en technisch directeur
DK Direktøren
og Teknisk Chef
S Verkställande direktör
52 Operating manual liquid ring vacuum pumps and compressors series TRH - TRS - TRM - TRV - SA & Systems type HYDROSYS - OILSYS