0% found this document useful (0 votes)
113 views13 pages

Welding Q4

This document contains 50 multiple choice questions related to welding codes and standards. The questions cover topics such as welding processes, filler metals, preheat and post weld heat treatment requirements, qualifications, and non-destructive testing. The document is a welding inspector examination with answers provided for each question.

Uploaded by

Ahmed Haridi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
113 views13 pages

Welding Q4

This document contains 50 multiple choice questions related to welding codes and standards. The questions cover topics such as welding processes, filler metals, preheat and post weld heat treatment requirements, qualifications, and non-destructive testing. The document is a welding inspector examination with answers provided for each question.

Uploaded by

Ahmed Haridi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 13

Name of Inspector:

Date:
Company:
1. WHICH AWS CODE DEALS WITH STANDARD
WELDING TERMS AND DEFINITION ----------------------
-
A) AWS A 2.4 B) AWS A 3.0 C) AWS A 1.1 D) AWS A
4.3
ANSWER:
2. WHICH ASME CODE DEALS WITH GAS
TRANSMISSION AND DISTRIBUTION OF PIPING
SYSTEM------------------------
A) ASME B 31.8 B) ASME B 31.3 C) ASME B 31.4
D) ASME B 31
ANSWER:
3. GTAW PROCESS CAN BE USED FOR ALL PASSES
FOR BUTT WELDS IN PIPING AND NOZZLE LESS
THAN ------------------NOMINAL DIAMETER
A) 20MM B) 1” C) 250 MM D) 30MM
ANSWER:
4. LOW HYDROGEN ELECTRODE MEANS ----------------
--------
A) LESS THAN OR EQUAL TO 8 GRAM OF
HYDROGEN PER 100 GRAM OF DEPOSITED
WELD METAL.
B) LESS THAN OR EQUAL TO 8 ML OF HYDROGEN
PER 100 GRAM OF
DEPOSITED WELD METAL.
C) LESS THAN OR EQUAL TO 0.8 ML OF
HYDROGEN PER 1000 GRAM
DEPOSITED WELD METAL.

D) BOTH A AND B
ANSWER:

5. COMPRESSED GAS ASSOCIATION CGA G-11.1


DEALS WITH -----------------
A) ARGON (GARDE A)
B) ARGON (TYPE A)
C) CO2 (TYPE A)
D) CO2 (GRADE A)

ANSWER:
6. IF THE PROCEDURE IS NOT QUALIFIED IN THE
VERTICAL POSITION
THEN THE DIRECTION OF WELDING SHALL BE---
------------------------

A) FLAT & HORIZONTAL


B) VERTICAL DOWN
C) FLAT
D) VERTICAL UP
ANSWER:
7. THE WIND VELOCITY IN THE WELD AREA FOR
GTAW, GMAW, OR GAS SHEILDED FCAW SHALL
NOT EXCEED --------------------------
A) 2.2 KM/S
B) 2.0 M/S
C) 8 KM/HR (2.2 M/S)
D) NONE OF THE ABOVE
ANSWER:

8. FOR PIPELINE GRATER THAN 16” DIAMETER


AT LEAST 2 WELDERS
SHALL BE USED IN THE OPPOSITE QUADRANT
IT (TRUE OR FALSE.)
ANSWER:
9. A PARTICULAR WELD JOINT SHALL BE
COMPLETED WITH IN---------
HOURS OF STARTING.

A) 48
B) 4
C) 24
D) 12

ANSWER:
10. THE USE OF NITROGEN AS A BACKING GAS
FOR STAINLESS STEEL
IS NOT PERMITTED (TRUE OR FALSE)
ANSWER:
11. THE BACK PURGE FOR CARBON AND LOW
ALLOY STEEL REDUCE
THE OXYGEN LEVEL BELOW -------------------

A) 2%
B) 1%
C) 0.5%
D) 6%
ANSWER:
12. THE MINIMUM DISTANCE BETWEEN TWO
PARALLEL BUTT WELD
SHALL BE ---------------------
A) 25 MM
B) 60MM
C) 20MM
D) BOTH A & C
ANSWER:
13. THE PREHEAT TEMPERATURE SHALL BE
ESTABLISHED OVER A MINIMUM DISTANCE
OF -------------------ON EACH SIDE OF THE
WELD.
A) 75MM
B) 70 MM
C) NONE OF THE ABOVE
D) 60MM
ANSWER:
14. THE MNIMUM PWHT SOAK TIME SHALL BE --
--------HOURS
A) 1.5 HOURS
B) 20 MIN
C) 1
D) 10 MIN
ANSWER:
15. THE REPAIR EXCEED 30%, THEN
RADIOGRAPHY SHALL INCREASE
TO -----------------------------
A) 30%
B) 60%
C) 50%
D) NONE
ANSWER:
16. WELD JOINT MAY BE REPAIRED ATLEAST ----
-------------------
A) SINGLE
B) TWICE
C) INFINITY
D) NONE
ANSWER:
17. THE REMOTE CURRENT CONTROL SHALL BE
USED IF THE
WELDING IS MORE THAN ----------------------
FROM THE WELDING
POWER SOURCE
A) 25M
B) 35M
C) 30M
D) BOTH B & C
ANSWER:
17. THE ELECTRODE SHALL BE STORED
CONTINUOUSLY IN OVEN AT
MINIMUM---------------------------CELCIUS
A) 200 DEG
B) 150 DEG
C) 145 DEG
D) NONE OF THE ABOVE
ANSWER:
18. AN OPENED SAW FLUXES SHALL BE STORED
IN A CONTAINER AT
------------------CELCIUS
A) 65 DEG
B) 70 DEG
C) 75 DEG
D) 60 DEG
ANSWER:
19. PRIOR TO USE ALL ELECTRODE SHALL BE
DRIED AT 260-430 D CEL
FOR --------------------------HOURS MINIMUM
A) 24 HR
B) 2 DAYS
C) NONE
D) 2 HR
ANSWER:
20. ALL WELDS ARE 100% RADIOGRAPHED NEAR
THE -------------------
OF PAVED ROAD, RAIL ROAD, AND AIR PORT
CROSSING.
A) 600M
B) 700M
C) 60M
D) BOTH A AND B
ANSWER:
21. WHICH SAES DEALS WITH WELDING
REQUIREMENTS FOR PRESSURE VESSEL-------
-----------------
A) W-10
B) W-11
C) W-14
D) W-17
ANSWER:
22. WHICH ONE IS NOT RELATED WITH
WELDING PROCEDURE SPECIFICATION

A) PRE HEAT
B) POSITION
C) FILLER METALS
D) NONE OF THE ABOVE
ANSWER:
23. ELECTRODES SHALL BE RE-DRIED ------------------
---------TIMES
A) 2
B) 1
C) RE-DRIED IS NOT ALLOWED
D) NONE
ANSWER:
24. WELDING CLEARANCE SHALL NOT BE LESS
THAN--------------------------
ALL AROUND THE PIPE

A) 400 MM
B) 900MM
C) 600 MM
D) NONE OF THE ABOVE
ANSWER:
25. WHAT IS THE MAXIMUM SMAW ELECTRODE TO
BE USED FOR NON LOW HYDOGEN ELECTRODE S----
-------------------

A) 4MM
B) 5MM
C) 6MM
D) NONE
ANSWER:
26. THE TIME FOR SECOND OR HOT PASS DURING
VERTICAL UP PROGRESSION IS-----------------------------
-
A) 6 MIN
B) 5 MIN
C) 15MIN
D) 1 HOURS
ANSWER:
27. SAIC-W-2048 DENOTE------------------------
A) PRE,DURING,FINAL WELDING INSPECTION
OF PIPELINES
B) SELECTION OF NDE
C) WELD SUMMARY
D) TEMPERATURE TIE-IN
ANSWER:
28. SATR –W-2013 DENOTE----------------------------------
A) WEEKLY WELDER REPAIR RATE
B) WEEKLY WELDER REPAIR RATE AND TRACER
WELD REPORT
C) WEEKLY WELD STATUS
D) NONE
ANSWER:
29. IN “E7018” ELECTRODE, THE NUMBER (1)
REFER TO
A) T.STRENGH
B) POSITION
C) CHEMICAL CHARACTERISTIC
D) NONE
ANSWER:
30. IN “EXXT-X” ELECTRODE, THE LETTER (T)
DENOTE----------------------

A) T.STRENGH
B) TUBULAR
C) POSITION
D) ALL THE ABOVE
ANSWER:
31. “ERXXS-X” RELATED TO WHICH PROCESS ---------
---------------

A) SMAW
B) GMAW
C) MMAW
D) FCAW
ANSWER:
32. IF THE WELD JOINT IS WET OR MOISTURE ON
THE SURFACE THEN HEATING FOR A DISTANCE OF-
--------------------------FROM THE WELD JOINT
A) 200MM
B) 100MM
C) 250MM
D) 75MM
ANSWER:
33. FOR PIPELINE LESS THAN 16” DIA ----------------
-----------------CLAMP
MAY BE USED
A) INTERNAL
B) EXTERNAL
C) BOTH A & B
D) INTERNAL ONLY
ANSWER:
34. WHAT IS THE FORMULA FOR HEAT INPUT?
35. IF A WELDER IS QUALIFIED FOR 0.75” DIA,
THEN WHAT IS THE MIN & MAX DIA HE IS
QUALIFIED?

A) 0.75” MIN & UNLIMITED


B) UNLIMITED
C) LESS THAN 0.75”MAX
D) WELDED SIZE & UNLIMITED
ANSWER:
36. IF A WELDER IS QUALIFIED FOR 2” THIKNESS
WHAT IS THE MAX
THICKNESS HE IS QUALIFIED?
A) LESS THAN 2”
B) UNLIMITED
C) GREATER THAN 2”
D) 1” O.D & ABOVE
ANSWER:
37. IF A WELDER WELDS 26” DIA PIPE, HE IS
QUALIFIED FOR 2G POSITIONS WHAT ARE ALL THE
POSITION HE IS QUALIFIED?
A) ALL
B) FLAT & O.H
C) VER & O.H
D) F & H
ANSWER:
39. GMAW & FCAW SHALL NOT BE USED FOR THE
ROOT PASS ON SINGLE SIDED TEE OR CORNER
JOINT. (SAY TRUE OR FALSE)
ANSWER:
40. PERMANENT BACKING RINGS OR STRIPS
SHALL BE USED OR NOT
ANSWER:
41. FOR PIPE DIA OF 101.6 M OR LESS, HOW
MANY EQUALLY SPACED TACKS ARE NEEDED?
A) 4
B) 3
C) 2
D) 1
ANSWER:
41. ANY TEMPORARY WELDED ATTACHMENTS
OR TEMPORARY TACK WELD SHALL GROUND
OFF, ATTACHMENTS MAY BE CUT OFF NO
CLOSER THAN --------------------FROM THE BASE
METAL SURFACE
A) 4MM
B) 3MM
C) 6MM
D) 7 MM
ANSWER:
42. AN INERT BACKING SHALL BE USED FOR
GTAW OR GMAW ROOT
PASSES ON THE SINGLE SIDED GROOVE
WELDS OF ASME------------
A) P.NO-1
B) P.NO-1A
C) P.NO-5 OR GREATER
D) P.NO-1B
ANSWER:

43. TEMPERATURE INDICATING CRAYON SHALL


BE USED FOR ANY WELD JOINT THAT IS TO BE
COATED- SAY (TRUE OR FALSE)

ANSWER:
44. THE PWHT SHALL BE APPLIED OVER AN AREA
EXTENDING ATLEAST -----------------------TIMES THE
THICKNESS OF THE MATERIAL TO BE WELDED
FROM THE EACH END OF THE WELD NOT LESS
THEN -------------------FROM EACH END OF THE WELD
A) 3 & 25 MM
B) 6 & 20 MM
C) NONE
D) 1.5 & 20 MM
ANSWER:
45. SAES –W 015 STANS FOR

A) STRIP LINING APPLICATION


B) WELDING REQUIREMENTS OF API TANKS
C) NONE
D) WELDING OF REQUIREMENTS OF
OFFSHORE STRUCTURES
ANSWER:
46. THE MAXIMUM HARDNESS NO FOR P1
MATERIALS IS -------------------
FOR SOUR SERVICE.
A) 150BHN
B) 200BHN
C) 500BHN
D) NONE
ANSWER:
47. WHAT IS THE MAXIMUM ACCEPTABLE ROOT
REINFORCEMENT-------

A) 5MM
B) 3MM
C) 7MM
D) 8MM
ANSWER:
48. ASME SEC II C DEALS WITH ------------------------
A) FERROUS MATERIALS
B) NON FERROUS MATERIALS
C) FILLER METALS,RODS,ELECTRODES
D) ALL THE ABOVE
ANSWER:
49. ASME SEC IX DEALS WITH-------------------

A) PRESSURE VESSEL
B) NDT
C) WELDING & BRAZING QUALIFICATION
D) NONE
ANSWER:
50. HI-LO GAUGE IS USED TO MEASURE-----------------
-----
A) MISALIGNMENT
B) ROOT GAP
C) ALL THE ABOVE
ANSWER:
ANSWERS
1. B
2. A
3. B
4. B
5. A
6. B
7. C
8. TRUE
9. C
10. TRUE
11. B
12. C
13. A
14. 1
15. C
16. B
17. C
18. A
19. D
20. C
21. A
22. D
23. B
24. B
25. B
26. C
27. A
28. A
29. B
30. B
31. B
32. B
33. C
34. H.I
35. A
36. D
37. D
38. OO
39. TRUE
40. SHALL NOT BE USED
41. B
42. C
43. FALSE
44. A
45. A
46. B
47. B
48. C
49. C
50. C

You might also like