0% found this document useful (0 votes)
371 views31 pages

Multipurpose Hall

This document provides a bill of quantities for a 50,000 MT silo project. It includes 17 line items describing various civil works such as clearing land, excavation, filling, compacting sub-base and base courses, concrete work, reinforcement, formwork, and structural steel work. The total estimated quantity of materials and work is provided in relevant measuring units such as square meters, cubic meters, and metric tons.

Uploaded by

Naiyer Azam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
371 views31 pages

Multipurpose Hall

This document provides a bill of quantities for a 50,000 MT silo project. It includes 17 line items describing various civil works such as clearing land, excavation, filling, compacting sub-base and base courses, concrete work, reinforcement, formwork, and structural steel work. The total estimated quantity of materials and work is provided in relevant measuring units such as square meters, cubic meters, and metric tons.

Uploaded by

Naiyer Azam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 31

BOQ_ SILO PROJECT 50000 MT

S. NO. DESCRIPTION OF ITEM UNIT

A CIVIL WORK

Clearing and grubbing land including uprooting all vegetations, grass, bush, shrubs, saplings and
trees, removal of stumps of trees of all sizes including removing stumps of trees cut earlier and
1 Sqm
disposal of unserviceable materials with a lead upto 2kms and lifts and as directed by Engineer-In-
Charge complete in all respects.

Excavation for foundation in earth, soil of all types, sand, gravel and soft murrum, including
removing the excavated material up to a distance of 1.0 Km. beyond the excavation area & stacking
2
and spreading as directed, dewatering, preparing the bed for the foundation . complete as per
specification and as directed by Engineer in charge complete in all respects.

a) For all depths Cum


Filling with available excavated earth i/c leads and lifts and compacting by vibratory roller (10 MT
3 capacity if required) all complete as per gradation plan, drawings and as directed by Engineer In Cum
Charge Complete in all respects.

Providing laying ,Cutting & Filling earth from outside i/c leads and lifts and compacting by
4 vibratory roller (10 MT capacity if required) all complete as per gradation plan, drawings and as Cum
directed by Engineer In Charge Complete in all respects.( Earth From outside)

Cutting & Filling with available earth i/c leads and lifts and compacting by vibratory roller (10 MT
4(a) capacity if required) all complete as per gradation plan, drawings and as directed by Engineer In Cum
Charge Complete in all respects.

Providing and laying Coarse Graded Granular sub-base (GSB) Grading-II in road and shoulder as
per Table 400.2 complete as per Technical Specification Clause 401, Table 401.2 (CBR value shall
not be less than 25%).Latest version of IS code shall be followed. Subgrade shall be compacted to
5 minimum 95 % density with OMC and with Vibratory roller of 10 T capacity. compaction will Cum
execute as per specified IS codes i/c watering, base cleaning etc as per drawing and as directed by
engineer in charge complete in all respects.
Latest IS code shall be followed.

Providing and laying Wet MIX Macadam (WMM/WBM) base course of compacted thickness in
slope as specified in the drawings and as per clause 406.2.1.2 of MORTH, laying with mechanical
machine and compacting by vibratory roller and directed by Engineer -In- Charge. compaction will
6 Cum
execute as per specified IS codes i/c watering, base cleaning etc as per drawing and as directed by
engineer in charge complete in all respects.
Latest IS code shall be followed.

Supply & laying 230 mm thk. rubble soling as per General Specifications and of approved quality,
lay rubble packing with interstices filled with approved murrum or stone dust, or sand watered and
rolled to compaction in line, level, gradient, etc. complete. Finished dimensions shall be measured.
7 Cum
(Wherever required),using 150 mm to 230mm random stone including filling the voids with 80mm
trap metal and sand / grit ramming properly , watering etc. complete as per specifications, drawings
and directed by Engineer-in-charge.
Providing & laying Plain Cement Concrete of M10 Grade with 20 mm size graded stone aggregate
including placing, vibrating, compacting, finishing the surface in smooth finish to the correct level
8 Cum
including base cleaning, watering necessary scaffolding shuttering, curing etc complete in all
respects as per drawing, specifications and as directed by engineer in charge.

Providing and laying machine mixed machine vibrated watertight controlled reinforced cement
concrete M25 grade (including providing & mixing of water reducing admixture / superpalsticizer
(Sika, Fosroc OR BASF) as per manufactures specifications) as per design mix by weigh batching
9 using 20mm and smaller size machine crushed black trap metal or approved coarse aggregates and
sand in all heights and depths, types and size, including watering, placing (pouring), necessary
scaffolding, staging, hoisting, leaving pockets for the pipe flanges, sockets, etc. as directed keeping
drip moulds, grooves if any including curing, testing, etc. complete.

For all levels Cum


9A Extra for M30 grade Cum

TREMIX VACUUM DE-WATERED CONCRETE FLOORING


Providing and laying of cement concrete tremix flooring, using truss screed for Cement concrete mix
M-25 and mixing of recron etc. complete in all respects. The dura vapour barrier shall be used at the
base of trimix flooring. Process shall consist of laying out of panels, placing side form channels to
10 true and proper level on cement mortar bed, poker vibrating the concrete followed by at least two Cum
passes of screed vibrator, followed by one pass of leveling beam, all using 2 to 3mm flat on sides to
allow for hrinkage on dewatering the consolidated slab, floating the vacuumed slab with one pass of
skim floater, finishing with at least two passes of trowel using skim floater to give desired finish.
Reinforcement steel shall be paid seperately.

Extra for vaccum dewatering on trimix flooring as per drawing, specification and direction of
10 (a) Sqm
engineer in charge complete in all respects.

Providing and mixing of Polymer Based hardner @ 5 kg /sqm to be mix in trimix flooring as per
10 (b) Sqm
specification and as directed by engineer in charge complete in all respects.

Extra for supplying and filling polysulfied sealent (5 x 10 mm) with debonding tape,backer rod (5 x
15 mm) in the contraction joint of the Floor panels (5 x 25 mm) including mechanical cutting of the
10 c) RM
grooves etc. complete as per speciifcations, drawings and as directed by EIC. Groove shall be cut
within 24 Hrs once concrete has attained final set.

Providing and fixing in position centering, shuttering, staging for formwork of a adequate capacity
including strutting, propping, etc. deshuttering, decentring, etc. complete for all type of RCC works
11 and at all levels as per specification. Surface of the concrete shalll be free of honey combing, used
formwork that might give honeycombed or rough surface shall be avoided. All work to be executed
as per approved SOP or as directed by engineer in charge complete in all respects.

a) For All Levels (Cilo Work ) Sqm


a) For All Levels (Admin Building Work) Sqm

Placing and binding in position FE-500 reinforcement as per drawing including straightening,
cutting to required length, bending, binding with 16 Gauge annealed wire, welding if necessary,
providing concrete cover blocks of required thickness, giving strength results including provision of
12
wastage, rolling margin etc. complete as directed and specified. Lap will be paid as per standard
length of bar. Chairs and spacers will be paid seperately as per IS Code. Rate includes cost of
binding wire.( Steel Supply Free of Cost Uttar Pradesh Logistics Private Limited)

a) HYSD of TMT Fe 415 / Fe 500 D grade conforming to IS 1786 MT


Supply, Fabrication and erection of structural steel work in rolled sections like joists, channels,
angles, tees and trusses, plates, pipes, R.S. J channels etc.as per detailed designs and drawings in
required line and level and as directed by EIC including cutting, fabrication, hoisting, erecting,
fixing in position, making bolted/welded connections and applying approved make paint etc, all
complete as per specifications. Welding shall be done by approved electrodes only (Advani, ESAB
or equivalent). Painting of exposed surfaces includes surface preparation with copper slag (dry
13 abrasive)cleaning as per Sa 2.5 ISO 8501-1 cleaned surface.. It also includes protective coating of MT
first coat of Red Oxide in single coat (50 microns DFT) application (Air less spray in single coat
application). And two coat of synthetic enamel paint (2x 35 =70 microns DFT) of approved shade
(air less spray application)(After localized touch up of handling damages/welding burn out area if
applicable) (Brush or airless spray application) of approved make of Shalimar, Berger, Asian or
Equivalent but approved by QA/QC and applied as per specification and as directed by Engineer in
charge. And Total DFT shall not be less than 120 microns DFT.

Fixing of Anchor bolts of required size and dia. including nuts and washers in required line and
14 level as per detail, including concreting etc. complete as per specifications and as directed by Nos
Engineer in charge.

Providing and laying non-shrink grout with "Conbextra GP2" of "Fosrock" OR "Samcrete GP" under
15 base plates including all materials, labour, tools and tackles, curing etc. as per drawings, Cum
manufacturer's specifications and as directed by the Engineer -In- Charge.

Making of pockets in required size, line and level as per detail, while concreting etc. complete as per
16 Nos
specifications and as directed by Engineer in charge
Providing and laying 6mm thick cement plaster on RCC slabs, soffits of RCC slabs, chhajjas, staris
etc. in single coat in cement mortar 1:3 (1 Cement : 3 Sand) including chicken wire mesh, hacking of
17 Sq.m.
RCC surfaces, scaffolding and curing etc. complete in all respects or as directed by engineer in
charge.

Providing and laying 12mm thick finished internal cement plaster in CM 1:4 ( 1 Cement : 4 Sand)
on block masnory or reinforced cement concrete/PCC surfaces including chicken wire mesh
18 Sq.m.
finishing, hacking of RCC surface, making groove, drip mouldes if required and scaffolding and
curing etc. all complete as per specification, drawings and as directed by Engineer in charge.

Providing and laying 20mm thick sand faced Double coat Mala plaster externally in cement mortar
using approved screened sand in all positions including base coat of 12mm thick in Cement Mortar
1:4 using approved waterproofing compound as per manufacturer's specification curing the same for
19 not less than 2 days and keeping the surface of the base coat rough to receive the sand faced Sq.m.
treatment of 6 to 8mm thick in Cement Mortar 1:3 finishing the surface by taking out grains and
curing for fourteen days, i/c chicken wire mise wherever required as IS standard maiking grooves,
drip cources, scaffolding etc. complete as per specification and as directed by Engineer in charge.

Providing & applying 3 coats of exterior acrylic emulsion "Apex" , Weather shield or equivalent
of approved shade at all heights including necessary scaffolding and surface preparation, curing and
20 base coat application with Birla White cement, etc. complete as per manufacturer's recommendation Sqm
,drawings and directions of Engineer In Charge. (Rate including all materials, labour, preparation
of surface, scaffolding, cleaning the doors and windows after painting etc. complete. )

Providing and applying internal Acrylic Emulsion paint on wall surfaces of approved colour and
shade of ICI or equivalent make in three coats over newly prepared surfaces with application of
21 sponge roller to give an even finish to the walls / ceiling including surface preparation, base coat Sqm
application with Birla White putty etc. complete as per manufacturer's recommendation ,drawings
and directions of EIC.
Providing and applying two or more coats white wash i/c base preparation complete in all respects as
22 Sqm
directed by engineer in charge.
Providing and applying two or more coats enamel paint on steel and wood exposesd surface i/c base
23 prepration as per specifications, two coats red oxide base primer, scaffolding etc complete in all Sqm
respects.

Providing and making stripes on the floor (Pavement marking) with hot applied Thermoplastic paint
24 conforming to ASTM D36/BS-3262 (Part - I) as per drawing and Technical Specification Clause sqm
803 for Lane /center line/edge line/ transverse marking and any other markings as directed by EIC.

Providing and applying top surface neat cement puning floor on 35 mm thk base of cement mortar
25 Sqm
1:4( 1 cement: 4 coarse sand complete in all respects).

Pre construction anti-termite treatment to buildings shall be with emulsifiable insecticides as per
IS: 6313 (part II) (latest revision). The Contractor shall carry out the work through an approved
26
agency and provide a guarantee for seven years on a stamp paper from an approved agency. Only
plinth area shall be measured for payment.

Treatment of soil under floor using chemical emulsion @ one litre per hole, 300 mm apart including
a) drilling 12 mm diameter holes and plugging with cement mortar 1 : 2 ( 1 cement : 2 coarse sand) to Sqm
match the existing level with Chlorpysiphos/Lindane E.C. 20 % with 1 % concentration.

Providing and laying Food Grade Epoxy to seal gaps between base plate and top of silo wall as per
27 Cum
drawing , specifications are as directed by EIC.

Providing and fixing constructing brick masonry of minimum compressive strength of 35 kg/cm2
including hoisting and setting in position with cement mortar 1:6 ( 1 cement : 6 coarse Sand)
28
including racking out the joints scaffolding staging, curing etc. in true line , level, plumb in all
shapes situations etc. complete as per drawings, specification and as directed by Engineer in Charge.

a) For all levels Cum


Providing and fixing Half brick masonry in common burnt clay building bricks having crushing
strength not less than 35 Kg/ Sq.Cm.In cement mortar 1:4 (1 Cement: 4-Fine sand) in Super
29 Structure as per specifications including providing recesses, opening, scaffolding, staging, curing, Cum
finishing the joints flush and raking out joints all complete at all depths & heights.(Including 6mm
two no steel Bar every 4 steps)

Providing and fixing of fully vitrified floor tiles in floor and skirting or
equivalent(jhonson/Bell/Refin or equivalent make), in floor having minimum thickness of 7.2 mm.,
in desired colour and size (600x600 mm ), as approved by Architect and Engineer-in-charge, scratch
hardness, minimum 7 on Mohr's scale with a density of 2.2 to 2.3, and bonding strength of 250
30 Sqm
kg/sqcm. also chemical resistance should be meet ASTM & DIN Standards as per manufacturer's
specifications. The tiles shall be fixed in CM 1:4 (1 cement : 4 sand), joint should be done with
approved grouting, materialsetc. complete. Floor protector to be provided to protect the floor from
scratches as directed by the Engineer In Charge.

Providing and fixing minimum 18 mm thick mirror polish, machine cut Shera Grey Granite stone
for Stair landing, treads / risers, window sill & Door jamb, Thresh hold, wall top etc. in size as
per the design and approval of the Architect over 20mm thick (average) base of 1:4 cement mortar (1
31 Sqm
cement: 4 coarse sand) laid and jointed with white cement slurry mixed with pigment to match the
shade of stone including curing, rubbing, mirror polish etc. complete as per specification , drawings
and directed by EIC. Over bed mortar, white cement slurry shall be laid @ 3.3 kg/Sq.Mt in flooring.
Providing and laying polished green kota stone of uniform thickness of 20 to 25 mm with three
/four side machine cut edges for parapet top, including necessary bedding material in CM (1:4) and
32 finished with neat cement match with Kota colour, Groove, mouldings, Handling, Scaffolding, Sqm
Mirror polishing etc complete as per specification , drawings and as directed and up to the
satisfaction of Engineer-In-Charge for all level & lead.
point of 150’c after having done surface preparation and Primer painting work between terrace deck
& APP membrane (thickness as per manufacturer specification). Tensile strength of 560/360 N/5cm
L/C and Elongation of 45% L/C and penetration of 80 dmm of 60’c by loosely onto the substrate by
torch on application method and sealing all the joints and the edges. The overlaps must be minimum
75 mm on the length side of the membrane and 100 mm on the width side of membrane and properly
thermo-fused. For termination, taking the membrane to the parapet through a fillet and terminating
after crossing the flat portion of the parapet. If the parapet is very high, or there is any wall, the
membrane shall be terminated after tucking inside after a height of 1 mtr. This has to be minimum
300 mm if height of 1 mtr. is not available. The membrane shall be inserted inside a groove of 40
mm and will be filled by cement sand mortar and bituminous cauking compound after tucking in the
33 Sqm
membrane. For areas, where there is no parapet, the membrane shall be taken down about 150 mm as
a drip course and terminated .
Flashing: After the insertion of membrane in the groove of the parapet, putting membrane of
Aluminium surface in a strip of 100 mm. Expansion Joints: Wherever there is any expansion joint, a
double layer floating treatment shall be done. Pond Test: Pond test is to be conducted for minimum
72 hours with 150 mm water-head. Hydro test shall be performed for terrace water proofing by the
contractor including filling, emptying and cost of water etc. complete before laying screed concrete
over membrane. Work shall be carried out through an approved specialized agency. The supplier
shall submit performance guarantee certificate for maintenance free period of 10 years.
After hydroand
Supplying test, screed
fixing concrete glazed
in position (M20) or
shall be laid
partly in slope
glazed, (based
openable, on slope
double & down
or single leaf spout details
anodized 25
micron M2 Grade ) aluminium doors having aluminium frame of Indal/ Jindal / Hindalco make, &
weight of aluminium sections as for door frames, model no-19581 (@1.384 kg/m), model no-19582
(@1.300 kg/m) & model no-19535 (@1.243 kg/m) for door shutters, model no-19115(@ 3.186
kg/m) & model no-19546 (@3.060 kg/m) for glass door, model no-14069 (1.093 kg/m)approx. 8
kg/ m2 of opening area (excluding the weight of beading for glass/ panel fixing), size and shape as
per details at any level & height. Rate to include for supplying and fixing necessary hold fasts, all
hardwares, fixtures and fastenings of anodized aluminium as per requirement or as per drawing with
34 5 mm thick MODI/ Saint Gobain float glass for top portion and 6mm thick both side laminated Sqm
composite compact sheet of Mariono or Royel Touch and of approved shade or Alluminium.
Composite Panel of Alucobond/ Alpolic/ Durabuild or equivalent approved make for bottom portion
up to height of 900mm with EPDM gasket felt, aluminium beading, with all accessories like SS
handle (600 mm long one side & 150 mm other side), 125 mm long heavy duty SS hinges, flush
tower bolts, concealed cylindrical lock , silicon sealant for water tightness at all sides etc. complete
as per details and direction of the Engineer. (Measurement on the basis of out to out dimensions of
the frame). All fixtures shall be of " Dorma " make.
Interface with wall surface shall be provided with polysulphide sealent to get watertightness.
P/F anodized aluminium work for windows, ventilators and partitions with extruded built up
standard tubular and other sections of Hindalco / Jindal make, using model no. 20829 (@785 gm
/mt) and 20830 (@ 909 gm/mt) - Jindal make for 2 - track windows, model no - 20831 (@1.06
kg/mt) and 20832 (@1.248 kg/mt) for 3 - track windows, model no.20833 (@ 1.398 kg/m), model
no. 20834 (@1.648 kg/m) for 4 - track windows and model no. 20736 (@0.547 kg/m),model no.-
20072 (@1.095 kg/m) & model no. 20073 (@1.092) for fix glass window, model no.-19360
(@0.124 kg/m) for glazing clip, model no 20737 (@607 gm/mt), 20738 (@0.547 kg/m) for window
shutters and model no-14069(@ 1093 gm/mt), 20001 (@1.657 kg/m) & 20073 (@1.092 kg/m) ,
35 Sqm
fixed with rawl plugs and screws or with fixing clips or with expansion hold fasteners including
necessary all hardwares, fixtures and fastening as per requirement or as per drawing,filling up of
gaps at junctions, at top bottom and sides with required EPDM gaskets etc. All sections shall be
smooth, rust free, straight, mitred & jointed mechanically wherever 'required including cleat angle,
aluminium snap beading for glazing/ panelling C.P. brass/stainless steel screws, nylon rollers with
ball bearings, silicon sealant in gaps, concealed lock handle, etc. all complete. ( All Alu Section
Anodised M2 Grade).Interface with wall surface shall be provided with polysulphide sealant to get
water tightness.
Providing & fixing aluminum sun control louvers on exterior elevation with jindal/ hindalco tubular
box section (WS1229-2.030 kg/m) and louver blades (WS 3785-0419 kg/m) or model no-20782
(@.429 kg/m) for sun control louvers blade - Jindal make, or as per Architect's detail and confirming
36 Sqm
to IS : 733 and IS : 1285 i/c all hardwares, fixtures and fastening as per requirement or as per
drawing, silicon sealant for water tightness at all sides etc complete as per Architectural detail
drawing and direction of engineer in charge.

Aluminium Partition consisting of Aluminium Sections 63.5 MM X 38.1 MM X 2.00 MM thick


hollow anodised of Jindal / Hindalco make conforming to IS733 and IS 1285. The anodizing shall be
transparent and complying IS 1868 (minimum anodic coating of grade AC 15). The Sections would
be installed at an interval of 3’6” vertically and bottom section of size 114.60 x 44.45 x 2mm
37 Aluminium snap beeding for glazing/panelling etc. and 5.5 mm thick float Transparent Glass Sq.M
including providing screwless aluminium glazing clip. Bottom upto 3’ Ht Will be provided with
ACP cladding sheet , fixing clips, fasteners, filling up of gaps at junction, top, bottom, & sides with
required PVC/Nepprene felt etc.. The joints shall be smooth, mitred and jointed with cleat angle etc
as per direction of engineer/site Incharge. Total height of the partition is 10'-0".

Providing and fixing of Hollow metal fire rated doors (Avians or Equivalent) with panic bar as per
38 sqm
IS 3614 part-1 & part-2 for stability and integrity. Pressed Galvanized steel confirming to IS 277.

Supplying and fixing of Mechanically operated 16 g sheet rolling shutters of approved make, made
of required size M.S. lathe interlocked together through their entire length and jointed together at the
end by end locks mounted on specially designed pipe shaft with brackets, side guides and
arrangements for inside and outside locking with gear operations complete including the cost of
providing and fixing necessary 27.5 cm long wire springs grade No. 2 and MS top cover of required
thickness for rolling shutters as directed by Engineer-In-Charge.

Painting of exposed surfaces includes surface preparation with copper slag (dry abrasive) blast
39 sqm
cleaning as per Sa 2.5 ISO 8501-1 cleaned surface. Blasting profile shall be in the range of 60-80
micron. It also includes protective coating of first coat of Red Oxide in single coat (50 microns
DFT) application (Air less spray in single coat application). And two coat of synthetic enamel paint
(2x 35 =70 microns DFT) of approved make (air less spray application)(After localized touch up of
handling damages/welding burn out area if applicable) (Brush or airless spray application) of
approved make of Shalimar, Berger, Asian or Equivalent but approved by QA/QC and applied as per
specification and as directed by Engineer in charge.Total DFT shall not be less than 120 microns
DFT. In case of GI surface approved shade coat shall be applied over each primer.

Providing and fixing ceramic tiles in floors and skirting make as per drawing, minimum thickness 9
mm and approved shade & pattern, including backing coat of minimum 20mm thick cement mortar
40 1:4 (1cement: 4coarse sand), filling & pointing the joints with approved joint filler (Laticrete or Sqm
equivalent) etc. comp. Floor protector to be provided to protect the floor from scratches as
directed by the Engineer In Charge.

Providing and fixing ceramic tiles in dado make as per drawing, minimum thickness 9 mm and
approved shade & pattern, including backing coat of minimum 20mm thick cement mortar 1:3
41 Sqm
(1cement: 3coarse sand), filling & pointing the joints with approved joint filler (Laticrete or
equivalent) etc. comp.

Providing and laying M25 Grade Pre-cast kerb Stone (300 X 450 X 150/165) for outer line of paved
area, including admixtures, if required, including bed concrete with plain cement concrete 1:4:8 and
42 Rmt.
finishing the joints with CM 1:3 etc. complete. The Rate incuding all materials, labour, tools,
shuttering etc. as per drawings, specifications and directed by Engineer -In- Charge.
Providing and applying kerb stone painting with one coat of primer and 2 coats of approved make
43 enamel paint of yellow and black color of 500 mm long alternative strip as per IS :133-1975, Morth Sqm
technical specification section 800 & IRC -35.
Providing and fixing bricks in floors on 40 mm sand bed compacted with vibratory plate compactors
44 as per IRC:SP:63-2004 including materials, labours, tools, tackles and plants complete as per Sqm
specifications and as directed by Engineer-In-Charge.

Providing, Laying & Fixing of 60 mm thick Minimum M 35 grade paver block on 40 mm sand bed
45 compacted with vibratory plate compactors as per IRC:SP:63-2004 including materials, labours, Sqm
tools, tackles and plants complete as per specifications and as directed by Engineer-In-Charge.

Providing, Laying & Fixing of 80 mm thick M40 grade paver block on 40 mm sand bed compacted
46 with vibratory plate compactors as per IRC:SP:63-2004 including materials, labours, tools, tackles Sqm
and plants complete as per specifications and as directed by Engineer-In-Charge.

Providing and Laying of RCC NP-4 class pipe including lowering in require grade and jointing with
collar joint in C.M. 1:1 with proportion, using jute string soaked in cement slurry, finishing joints
47
and laying pipes to the designed grade and levels, curing etc.complete for all leads and lifts as
directed by Engineer-in-charge.
a) 200 mm Dia. RCC Hume Pipe Rmt.
b) Same as above but 200 mm dia. NP 3 Hume pipe Rmt.
Providing and fixing in true line and level false ceiling system at all heights including tiles of 600 x
600 ARMSTRONG Mineral Fiber ceiling tiles (Or approved equivalent)of type Prima dune plus (Or
approved equivalent) with Micro look. NRC of tile should be 0.50 Avg. Tile shall laid on Armstrong
grid systems (Or approved equivalent)with 15mm wide T-section flanges colour white. The
framework comprise of main runner spaced at 1200mm centres securely fixed to the structural soffit
by approved hangers at 1200mm maximum centres. Hangers (GI wire of 4.0mm dia) to be fixed by
approved roof plug, level adjusters and screws etc. The last hanger at the end of each main runner
should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees
48 Sqm
(with double stitching) to be interlocked between main runners at 600mm centres to form
1200x600mm modules. 'Cut cross tees longer than 600mm to be supported independently.
600mmx600mm modules to be formed by fitting 600mm long flush fitting cross tees centrally
between the 1200mm cross tees. Perimeter trim to be Armstrong wall angle secured to walls at
450mm maximum centres. Job includes cutting, making, diffusers, grills, light fixtures, etc
complete. Entire work shall be carried out as per shown on drawings and as per satisfaction of Site In
charge at all levels. Thermal Insulation of minimum 25mm thk. thermocol material to be provided
on the top of the ceiling.

Providing and fixing 28mm thk PVC / Sintex Doors of standard size(0.75/0.8 x 2.1) with Solid PVC
frame and shutter made of extruded PVC solid sections and grey shade as per manufacturers
49 specification etc. including all hardware hinges, tower bolts, aldrops, Door Accessories etc. fixing Sqm
joints fill with sealant complete, as per drawings and specifications given by Engineering -In-
Charge. (Sintex, Fomura, Solidor make).
respects ditected by engineer in charge.
a) Providng and fixing M-25 Grade cast in situ RCC pedestal (Size 450x450x600mm) in foundation
including excavation, reinforcement, shuttering, back filling, dressing etc. complete in all respects.
b) Providing and fixing of precast poles and panels, fixing of angle post, fixing of barbed wire,
including filling of panel joints, panel - pole joints, grouting as required, tamping, curing and
rendering, if required to give a smooth and even surface etc. all complete as per specifications,
drawings and and as directed by Engineer in charge.
c) Providing precast cement concrete panles of size (300 x 50 x 2140 mm) of M25 grade including
shuttering, ramming and tampering, curing, etc., complete as per detailed specifications and drawing
in true line , level, plumb etc. complete as per specification and as directed by Engineer in Charge.
49 d) Providing precast cement concrete poles of size (150 x 150 x2750 mm) of M25 grade including Rmt
shuttering, ramming and tampering, curing, etc., complete as per detailed specifications and drawing
in true line , level, plumb etc. complete as per specification and as directed by Engineer in Charge.
e) Providing and of concertina coil 450 mm dia, thickness (2.5+0.5) mm wire dia with zinc coated
250gm/sqm, ultimate tensile strength 140 -160 Kg/mm2,Weight not less than 13 Kg for 450 mm dia
80 no. of circles & 8.5 Kg for 450 mm dia 80 nos. of circles,130 to 180 no of clips as per 304AISI
with 1.5 mm thickness,50 mm thick 19 mm width strip with zinc coated 120 gm/m2 etc. complete as
per drawing, specification and as directed by Engineer-in-charge
e)Providing and fixing of G.I. Barbed wire fencing with Angle post 50x50 6mm as per drawing,
with barbed wire 6 horizontal rows on side of Y - shape interwoven with horizontal wires, of GI
barbed
Providingwires of designation
& laying A-4boulder
well graded IS 278materials
(Type A,(100
Sizemmdesignation-4,
to 50 mm) in2.65 mm
layers, dia) between
watered two
according
50 Cum.
to lines and levels or as directed by EIC.
Providing and laying gravel (25 - 10 mm )in filtration chamber as per drawing, specification and as
51 directed by engineer-in-charge

a) 25 mm - 10 mm Cum.
b) 10 mm - 6mm Cum.
c) Pea Gravel Cum.
Providing and laying coarse sand ( Sand free of silt and clay) as per drawing, specification and as
52 directed by engineer-in-charge Cum.

D ROAD WORK

Excavation for foundation in earth, soil of all types, sand, gravel and soft murrum, including
removing the excavated material up to a distance of 1.0 Km. beyond the excavation area & stacking
1 Cum
and spreading as directed, dewatering, preparing the bed for the foundation . complete as per
specification and as directed by Engineer in charge complete in all respects.

Construction of Subgrade and lower part of GSB with excaveted material in 250 mm layer wise
satisfying the requirements of minimum soaked CBR value as indicated in the drawings including
2 Cum
leads & lifts uo to distance of 2.0 km, all complete as per MoRT&H Technical Specification Clause
305. CBR value shall not be less than 12%.

Filling with available excavated earth i/c leads and lifts and compacting by vibratory roller (10 MT
3 capacity if required) all complete as per gradation plan, drawings and as directed by Engineer In Cum
Charge Complete in all respects.

Providing and laying Coarse Graded Granular sub-base (GSB) Grading-II in road and shoulder as
per Table 400.2 complete as per Technical Specification Clause 401, Table 401.2 (CBR value shall
not be less than 25%).Latest version of IS code shall be followed. Subgrade shall be compacted to
4 minimum 95 % density with OMC and with Vibratory roller of 10 T capacity. compaction will Cum
execute as per specified IS codes i/c watering, base cleaning etc as per drawing and as directed by
engineer in charge complete in all respects.
Latest IS code shall be followed.
Providing and laying Wet MIX Macadam (WMM/WBM) base course of compacted thickness in
slope as specified in the drawings and as per clause 406.2.1.2 of MORTH, laying with mechanical
machine and compacting by vibratory roller and directed by Engineer -In- Charge. compaction will
5 Cum
execute as per specified IS codes i/c watering, base cleaning etc as per drawing and as directed by
engineer in charge complete in all respects.
Latest IS code shall be followed.

Providing and laying Dense Bituminous Macadam (DBM) course complete as per MoRT&H
6 Cum
Technical Specification Clause 507.
Providing and laying Bituminous Concrete (BC) wearing course complete as per MoRT&H
7 Cum
Technical Specification Clause 509.
Providing bituminous prime coat @ 6kg/10 sqm over granular surface with bitumen emulsion
8 Sqm
complete as per Technical Specification Clause 502.
Providing emulsified tack coat over granular surface treated with primer/ existing surface @ 3 kg/10
9 Sqm
sqm as per Technical Specification Clause 503.

Providing and laying machine mixed machine vibrated watertight controlled plain cement concrete
M20 grade (including providing & mixing of superpalsticizer ( cico or equiv) as per manufactures
specifications) as per design mix by weigh batching using 20mm and smaller size machine crushed
black trap metal or approved coarse aggregates and sand in all heights and depths, types and size,
10 Cum
including watering, placing (pouring), necessary scaffolding, staging, hoisting, leaving pockets for
the pipe flanges, sockets, etc. as directed keeping drip moulds, grooves if any including curing,
necessay testing as directed by EIC and our QA/QC team, etc. complete. (Rate excluding
reinforcement, shuttering work).

Gst Extra as per Actual


QUANTITY AS
PER SITE RATES
ACTUAL
Rate Amount

18075.75 30 542,273

9669 150 1,450,350

3134.25 65 203,726

48000 250 12,000,000

1 155 155

1 2,400 2,400

1 2,500 2,500

1 2,700 2,700
646.5 5,000 3,232,500

472 6,500 3,068,000


3000 7,000 21,000,000

31.5 7,200 226,800

3206.25 110 352,688

3206.25 98 314,213

450 135 60,750

0 -

8000 700 5,600,000


2000 400 800,000

0 -

237.75 11,000 2,615,250


37.875 90,000 3,408,750

842.25 700 589,575

20.625 80,000 1,650,000

741 1,000 741,000

215.25 225 48,431

1185 350 414,750

1166.25 430 501,488

1554.75 250 388,688

1146 290 332,340


4125 150 618,750

82.5 200 16,500

110.25 607 66,922

139.5 385 53,708

0 -

4713.75 225 1,060,594

1.5 350,000 525,000

0 -

252.75 5,000 1,263,750

160.5 747 119,894

183.75 1,000 183,750

11.25 3,720 41,850


42.75 1,380 58,995

93.75 365 34,219

61.5 3,000 184,500

41.25 2,985 123,131


2.25 3,100 6,975

1 2,850 2,850

2.25 4,850 10,913

44.25 3,500 154,875

8 1,350 10,125

4.5 1,450 6,525

1192.5 752 896,760


477 450 214,650

156 250 39,000

686 880 603,240

7,045 1,050 7,396,988

0 -

12 600 7,200
31.5 750 23,625

141 1,200 169,200

3.75 4,500 16,875


802.5 2,850 2,287,125

1.2 2,000 2,400

0 -

1.2 2,100 2,520


1.2 2,000 2,400
1.2 2,100 2,520

1.2 1,900 2,280

0 -

6522 150 978,300

7344.75 2,350 17,260,163

2127 65 138,255

2067.75 2,350 4,859,213


1997.25 2,500 4,993,125

798 6,300 5,027,400

531.75 9,000 4,785,750

2067.75 65 134,404

3676.5 45 165,443

6.75 6,000 40,500

114,142,483
S.no

1
Work description

Clearing and grubbing land including uprooting all vegetations, grass, bush, shrubs, saplings and trees, removal of
stumps of trees of all sizes including removing stumps of trees cut earlier and disposal of unserviceable materials with a
lead upto 2kms and lifts and as directed by Engineer-In-Charge complete in all respects.

Silos area + office area


Excavation for foundation in earth, soil of all types, sand, gravel and soft murrum, including removing the excavated
material up to a distance of 1.0 Km. beyond the excavation area & stacking and spreading as directed, dewatering,
preparing the bed for the foundation . complete as per specification and as directed by Engineer in charge complete in
all respects.
Silos area 10 nos.
Prosses tower

Filling with available excavated earth i/c leads and lifts and compacting by vibratory roller (10 MT capacity if required)
all complete as per gradation plan, drawings and as directed by Engineer In Charge Complete in all respects.

Filling with available excavated earth i/c leads and lifts and compacting by vibratory roller (10 MT capacity if required)
all complete as per gradation plan, drawings and as directed by Engineer In Charge Complete in all respects.

Providing laying ,Cutting & Filling earth from outside i/c leads and lifts and compacting by vibratory roller (10 MT
capacity if required) all complete as per gradation plan, drawings and as directed by Engineer In Charge Complete in
all respects.( Earth From outside)

Cutting & Filling with available earth i/c leads and lifts and compacting by vibratory roller (10 MT capacity if required)
all complete as per gradation plan, drawings and as directed by Engineer In Charge Complete in all respects.

Providing and laying Coarse Graded Granular sub-base (GSB) Grading-II in road and shoulder as per Table 400.2
complete as per Technical Specification Clause 401, Table 401.2 (CBR value shall not be less than 25%).Latest
version of IS code shall be followed. Subgrade shall be compacted to minimum 95 % density with OMC and with
Vibratory roller of 10 T capacity. compaction will execute as per specified IS codes i/c watering, base cleaning etc as
per drawing and as directed by engineer in charge complete in all respects.
Latest IS code shall be followed.

Silos (GSB filling)

Providing and laying Wet MIX Macadam (WMM/WBM) base course of compacted thickness in slope as specified in
the drawings and as per clause 406.2.1.2 of MORTH, laying with mechanical machine and compacting by vibratory
roller and directed by Engineer -In- Charge. compaction will execute as per specified IS codes i/c watering, base
cleaning etc as per drawing and as directed by engineer in charge complete in all respects.
Latest IS code shall be followed.

Supply & laying 230 mm thk. rubble soling as per General Specifications and of approved quality, lay rubble packing
with interstices filled with approved murrum or stone dust, or sand watered and rolled to compaction in line, level,
gradient, etc. complete. Finished dimensions shall be measured. (Wherever required),using 150 mm to 230mm random
stone including filling the voids with 80mm trap metal and sand / grit ramming properly , watering etc. complete as per
specifications, drawings and directed by Engineer-in-charge.

Providing & laying Plain Cement Concrete of M10 Grade with 20 mm size graded stone aggregate including placing,
vibrating, compacting, finishing the surface in smooth finish to the correct level including base cleaning, watering
necessary scaffolding shuttering, curing etc complete in all respects as per drawing, specifications and as directed by
engineer in charge.
tunnel (Base)
Tower (base)
slab bottom

Providing and laying machine mixed machine vibrated watertight controlled reinforced cement concrete M25 grade
(including providing & mixing of water reducing admixture / superpalsticizer (Sika, Fosroc OR BASF) as per
manufactures specifications) as per design mix by weigh batching using 20mm and smaller size machine crushed black
trap metal or approved coarse aggregates and sand in all heights and depths, types and size, including watering, placing
(pouring), necessary scaffolding, staging, hoisting, leaving pockets for the pipe flanges, sockets, etc. as directed keeping
drip moulds, grooves if any including curing, testing, etc. complete.

Silos ring foundation


Silos ring Wall
Silos Slab
tunnel wall (4 nos)
tunnel wall (back side)
Tower foundation
Tower pit wall

Total concrete

Extra for vaccum dewatering on trimix flooring as per drawing, specification and direction of engineer in charge
complete in all respects.

Providing and mixing of Polymer Based hardner @ 5 kg /sqm to be mix in trimix flooring as per specification and as
directed by engineer in charge complete in all respects.

Extra for supplying and filling polysulfied sealent (5 x 10 mm) with debonding tape,backer rod (5 x 15 mm) in the
contraction joint of the Floor panels (5 x 25 mm) including mechanical cutting of the grooves etc. complete as per
speciifcations, drawings and as directed by EIC. Groove shall be cut within 24 Hrs once concrete has attained final set.

Providing and fixing in position centering, shuttering, staging for formwork of a adequate capacity including strutting,
propping, etc. deshuttering, decentring, etc. complete for all type of RCC works and at all levels as per specification.
Surface of the concrete shalll be free of honey combing, used formwork that might give honeycombed or rough surface
shall be avoided. All work to be executed as per approved SOP or as directed by engineer in charge complete in all
respects.
Silos outer
Silos inner
Silos outer Wall
Silos inner Wall
Silos Slab
tunnel wall (4 nos)
tunnel wall (back side)
Tower foundation
Tower pit wall
Placing and binding in position FE-500 reinforcement as per drawing including straightening, cutting to required
length, bending, binding with 16 Gauge annealed wire, welding if necessary, providing concrete cover blocks of
required thickness, giving strength results including provision of wastage, rolling margin etc. complete as directed and
specified. Lap will be paid as per standard length of bar. Chairs and spacers will be paid seperately as per IS Code. Rate
includes cost of binding wire.( Steel Supply Free of Cost Uttar Pradesh Logistics Private Limited)

HYSD of TMT Fe 415 / Fe 500 D grade conforming to IS 1786

Supply, Fabrication and erection of structural steel work in rolled sections like joists, channels, angles, tees and trusses,
plates, pipes, R.S. J channels etc.as per detailed designs and drawings in required line and level and as directed by EIC
including cutting, fabrication, hoisting, erecting, fixing in position, making bolted/welded connections and applying
approved make paint etc, all complete as per specifications. Welding shall be done by approved electrodes only
(Advani, ESAB or equivalent). Painting of exposed surfaces includes surface preparation with copper slag (dry
abrasive)cleaning as per Sa 2.5 ISO 8501-1 cleaned surface.. It also includes protective coating of first coat of Red
Oxide in single coat (50 microns DFT) application (Air less spray in single coat application). And two coat of synthetic
enamel paint (2x 35 =70 microns DFT) of approved shade (air less spray application)(After localized touch up of
handling damages/welding burn out area if applicable) (Brush or airless spray application) of approved make of
Shalimar, Berger, Asian or Equivalent but approved by QA/QC and applied as per specification and as directed by
Engineer in charge. And Total DFT shall not be less than 120 microns DFT.

Fixing of Anchor bolts of required size and dia. including nuts and washers in required line and level as per detail,
including concreting etc. complete as per specifications and as directed by Engineer in charge.

Providing and laying non-shrink grout with "Conbextra GP2" of "Fosrock" OR "Samcrete GP" under base plates
including all materials, labour, tools and tackles, curing etc. as per drawings, manufacturer's specifications and as
directed by the Engineer -In- Charge.
Making of pockets in required size, line and level as per detail, while concreting etc. complete as per specifications and
as directed by Engineer in charge

Providing and laying 6mm thick cement plaster on RCC slabs, soffits of RCC slabs, chhajjas, staris etc. in single coat
in cement mortar 1:3 (1 Cement : 3 Sand) including chicken wire mesh, hacking of RCC surfaces, scaffolding and
curing etc. complete in all respects or as directed by engineer in charge.

Providing and laying 12mm thick finished internal cement plaster in CM 1:4 ( 1 Cement : 4 Sand) on block masnory
or reinforced cement concrete/PCC surfaces including chicken wire mesh finishing, hacking of RCC surface, making
groove, drip mouldes if required and scaffolding and curing etc. all complete as per specification, drawings and as
directed by Engineer in charge.

Providing and laying 20mm thick sand faced Double coat Mala plaster externally in cement mortar using approved
screened sand in all positions including base coat of 12mm thick in Cement Mortar 1:4 using approved waterproofing
compound as per manufacturer's specification curing the same for not less than 2 days and keeping the surface of the
base coat rough to receive the sand faced treatment of 6 to 8mm thick in Cement Mortar 1:3 finishing the surface by
taking out grains and curing for fourteen days, i/c chicken wire mise wherever required as IS standard maiking grooves,
drip cources, scaffolding etc. complete as per specification and as directed by Engineer in charge.

Providing & applying 3 coats of exterior acrylic emulsion "Apex" , Weather shield or equivalent of approved shade at
all heights including necessary scaffolding and surface preparation, curing and base coat application with Birla White
cement, etc. complete as per manufacturer's recommendation ,drawings and directions of Engineer In Charge. (Rate
including all materials, labour, preparation of surface, scaffolding, cleaning the doors and windows after painting etc.
complete. )

Providing and applying internal Acrylic Emulsion paint on wall surfaces of approved colour and shade of ICI or
equivalent make in three coats over newly prepared surfaces with application of sponge roller to give an even finish to
the walls / ceiling including surface preparation, base coat application with Birla White putty etc. complete as per
manufacturer's recommendation ,drawings and directions of EIC.

Providing and applying two or more coats white wash i/c base preparation complete in all respects as directed by
engineer in charge.
Providing and applying two or more coats enamel paint on steel and wood exposesd surface i/c base prepration as per
specifications, two coats red oxide base primer, scaffolding etc complete in all respects.
Nos. Length Width Height Unit Qty

Total Sqm 84984

10.00 3.14 289 1.8 Cum 16334.28

2 175.5 33 1.8 Cum 20849.4


1 16.93 8 5.675 Cum 768.622
Total Cum 37952.302

10 3.14 256 0.25 Cum 4019.2

Total Cum 4019.2

10 100.48 0.9 0.1 Cum 90.432

2 182 2.7 0.1 Cum 98.28


2 37 2.7 0.1 Cum 19.98
1 15 15 0.1 Cum 22.5
10 3.14 256 0.1 Cum 803.84

Total Cum 1035.032

10 100.48 0.7 0.6 Cum 422.016


10 100.48 0.25 2 Cum 502.4
10 3.14 256 0.15 Cum 1205.76
4 182 2 0.25 Cum 364
4 37 2 0.25 Cum 74
2 20.5 0.5 2.8 Cum 57.4
2 20.5 0.4 1.25 Cum 20.5
2 20.5 0.3 2.1 Cum 25.83
1 14 0.2 2.25 Cum 6.3 16.2
1 21.5 0.5 1.25 Cum 13.4375
1 21.5 0.3 1.75 Cum 11.2875
Total cum 2702.931

10 100.48 0.6 Sqm 602.88


10 96.084 0.6 Sqm 576.504
10 99.067 2 Sqm 1981.34
10 100.637 2 Sqm 2012.74
10 100.48 0.15 Sqm 150.72
8 182 2 Sqm 2912
8 37 2 Sqm 592
2 20.5 2.8 Sqm 114.8
2 20.5 1.25 Sqm 51.25
2 20.5 2.1 Sqm 86.1
2 14 2.25 Sqm 63 16.2
2 21.5 1.25 Sqm 53.75
2 21.5 1.75 Sqm 75.25

10 100 nos 1000


644 0.25 161

84984

3.14 256 0.25 200.96

-2.5 16 0.25 -10

You might also like