Error Code Refrigerators
Error Code Refrigerators
Table of Contents
VOLTAGE AT POWER SUPPLY SOURCE .................................................................................................................................................................. 3
Error Codes in RS EON 603 Side By Side Refrigerator ............................................................................................................................................ 4
Error Codes in Converti Refrigerator ..................................................................................................................................................................... 8
Error Codes in Vesta Refrigerator ........................................................................................................................................................................13
Error Codes in NXW Refrigerator .........................................................................................................................................................................18
ERROR CODES IN RS EON VELVET RIT (SIDE BY SIDE) REFRIGERATOR ..................................................................................................................22
ERROR CODES IN RM EON VELVET RFD (4 Door) REFRIGERATOR .........................................................................................................................27
Steps for Diagnosis of PCB failure (LED indication Pattern)..................................................................................................................................31
Internal
Error Code E1
Malfunction decision The resistance across the refrigerator sensor wire should be approximately 2 kΩ at 25 ⁰C. The resistance
conditions should decrease with increase in temperature.
Supposed causes ● Disconnected sensor
● Sensor open or short
● PCB faulty
OK
V
Not OK
Check the resistance
value of the sensor Change the Sensor
OK
Error Code E2
Malfunction decision The resistance across the Freezer sensor wire should be approximately 2 kΩ at 25 ⁰C. The resistance
conditions should decrease with increase in temperature.
Supposed causes ● Disconnected sensor
● Sensor open or short
● PCB faulty
OK
V
Not OK
Check the resistance
value of the sensor Change the Sensor
OK
Error Code E6
Malfunction decision When Main PCB is not receiving communication form Display PCB or Door switch or Damper motor or inverter card
conditions the Display shows E6.
Supposed causes ● Disconnected connectors
● Wire open
● PCB faulty
OK
V
Not OK
Check wire
continuity between Internal wire defect
main PCB and display
OK
Error Code E9
Malfunction decision The resistance across the Defrost sensor wire should be approximately 2 kΩ at 25 ⁰C. The resistance should
conditions decrease with increase in temperature.
Supposed causes ● Disconnected sensor
● Sensor open or short
● PCB faulty
OK
V
Not OK
Check the resistance
value of the sensor Change the Sensor
OK
OK
V
Not OK
Check the resistance
value of the sensor Change the Sensor
OK
OK
V
Not OK
Check the resistance
value of the sensor Change the Sensor
OK
OK
V
Not OK
Check the resistance
value of the sensor Change the Sensor
OK
Supposed causes Memory recall feature may fail if there is power interruption at the moment when data is being
written to memory.
OK
V
Not OK
Check the resistance
value of the sensor Change the Sensor
OK
Communication Error
OK
V
Not OK
Check wire
continuity between Internal wire defect
main PCB and display
& Inverter PCB
OK
OK
V
Not OK
Check the resistance
value of the sensor Change the Sensor
OK
OK
V
Not OK
Check the resistance
value of the sensor Change the Sensor
OK
Door Alarm:
If door is left open for more than 2 mins the LEDs as per set temperature settings may
start blinking.
Error Code E1
Malfunction decision When Main PCB is not receiving communication form Display PCB or Door switch or Damper motor or inverter card
conditions the Display shows E1.
Supposed causes ● Disconnected connectors
● Wire open
● PCB faulty
OK
V
Not OK
Check wire contunity
between main PCB Internal wire defect
and display
OK
Error Code E2
Malfunction decision The resistance across the Refrigerator sensor wire should be approximately 2.1 kΩ at 25 ⁰C. The
conditions resistance should decrease with increase in temperature.
Supposed causes ● Disconnected sensor
● Sensor open or short
● PCB faulty
OK
Not OK
Check the resistance
value of the sensor Change the Sensor
OK
Error Code E3
Malfunction decision The resistance across the Defrost sensor wire should be approximately 2.1 kΩ at 25 ⁰C. The
conditions resistance should decrease with increase in temperature.
OK
Change PCB
Internal
Error Code D1
Malfunction decision Demo mode. All LED working but compressor won’t run
conditions
Supposed causes ● Demo mode Activated
OK
V
Note:
Er and Ec code will be displayed only in 4 hours after power-on.
Internal
For E0 error as sensor is part of Panel, changing panel is the only solution.
*Always check if switching refrigerator On and Off solves the issue first
Internal