Maritrans Version18
Maritrans Version18
Maritrans Version18
Uses Consumption
• Transparent waterproofing of Balconies and Terraces 0,8 - 1,2 kg/m2 in two or three layers.
• Transparent waterproofing of Ceramic surfaces This coverage is based on application by roller onto a smooth
• Transparent waterproofing of Glass and Glass-Bricks surface in optimum conditions. Factors like surface porosity,
• Transparent waterproofing and protection of Natural Stones temperature and application method can alter consumption.
• Transparent waterproofing of Transparent Plastics
(e.g. Polyacrylate, Polycarbonate)
• Transparent waterproofing and protection of Wood Colors
Also used as a transparent binder resin for sandcarpet exterior The MARITRANS coating is supplied transparent.
floor coating applications.
Technical Data *
PROPERTY RESULTS TEST METHOD
Composition Polyurethane high-solids pre-polymer
Elongation at Break 322% DIN EN ISO 527
Tensile Strength 25.4 N/mm 2 DIN EN ISO 527
E-modulus 69.5 N/mm 2 DIN EN ISO 527
Tear resistance 56.9 Ν/mm DIN ISO 34, Method Β
Elongation at break after 2000h of accelerated aging 298% DIN EN ISO 527
(DIN EN ISO 4892-3, 400 MJ/m2)
Tensile strength after 2000h of accelerated aging 25.5 N/mm 2 DIN EN ISO 527
(DIN EN ISO 4892-3, 400 MJ/m2)
Gloss retention after 2000h of accelerated aging Good DIN 67530
(DIN EN ISO 4892-3, 400 MJ/m2)
Surface chalking after 2000h of accelerated aging No chalking observed. DIN EN ISO 4628-6
(DIN EN ISO 4892-3, 400 MJ/m2) Chalking grade 0
Hardness (SHORE D Scale) 25 ASTM D 2240
Water vapor permeability 8.05 gr/m2 .24hours EN ISO 12572
Resistance to Water Pressure No Leak (1m water column, 24h) DIN EN 1928
Adhesion to absorbent ceramic tile >2,0 N/mm 2 (ceramic tile failure) ASTM D 903 (ELCOMETER)
Hydrolysis (5% KOH, 7days cycle) No significant elastomeric change Inhouse Lab
Service Temperature -40oC to +90oC Inhouse Lab
Tack Free Time 6-8 hours
Light Pedestrian Traffic Time 24 hours Conditions: 20oC, 50% RH
Final Curing time 7 days
Chemical Properties Good resistance against detergents, seawater and oils.
Application as a Transparent Waterproofing Coating.
Surface Preparation
Careful surface preparation is essential for optimum finish and durability.
The surface needs to be clean, dry and sound, free of any contamination, which may harmfully affect the adhesion of the membrane.
Maximum moisture content should not exceed 5%. New concrete structures need to dry for at least 28 days. Old coatings, dirt, fats,
oils, organic substances and dust need to be removed. Activate (prime) and degrease glass and glazed surfaces with the
MARISEAL® TILE-PRIMER. Possible surface irregularities need to be smoothened. Any loose pieces and dust need to be thoroughly
removed. Do not wash surface with water!
ATTENTION: Surfaces with trapped moisture (e.g. trapped moisture under tiles) must be left to dry completely (max. 5% moisture),
before the application of the MARITRANS coating.
WARNING: Do not apply the MARITRANS on ceramic surfaces with ascending nitric salts in the joints, without suitable pre-
treatment. Do not apply the MARITRANS on surfaces treated in the past with active silane, siloxane, silicon or other water-
repellents, because of expected poor adhesion. We recommend an adhesion test, if circumstances and surface history are not clear.
On marble and granite please perform an adhesion test, to ensure that adhesion is proper.
Finishing
If a satin matt surface is desired, apply one layer of the MARITRANS FINISH.
WARNING: The MARITRANS and/or the MARITRANS SYSTEM is slippery when wet. In order to avoid slipperiness during wet
days, sprinkle suitable aggregates onto the still wet coating to create an anti-slip surface. Please contact our R+D Dept. for more
details.
If applied onto concrete, make sure that the surface is clean, dry and sound, free of any contamination, which may harmfully affect
the adhesion of the membrane. Maximum moisture content should not exceed 5%. New concrete structures need to dry for at least
28 days. Old coatings, dirt, fats, oils, organic substances and dust need to be removed. Possible surface irregularities need to be
smoothened. Any loose pieces and dust need to be thoroughly removed. Do not wash surface with water!
Priming
Prime concrete surfaces with MARISEAL 750 primer and broadcast silica sand while still wet.
Sandcarpet Coating
Mix the MARITRANS with colored Silica Sand (corn size 0,7-1,2mm or 2,0-3,5mm) in a mixing ratio of 1:10 (resin: sand) by
weight, with a low speed mechanical mixer, until the mixture becomes fully homogenous.
Pour the mixture onto the prepared surface and apply by flat trowel.
For best results, the temperature during application and cure should be between 5oC and 35OC. Low temperatures retard cure while
high temperature speed up curing. High humidity may affect the final finish.
Packaging
MARITRANS is supplied in 20 kg, 10 kg, 5 kg and 1kg pails. Pails should be stored in dry and cool rooms for up to 9 months.
Protect the material against moisture and direct sunlight. Storage temperature: 5 0-300C. Products should remain in their original,
unopened containers, bearing the manufacturers name, product designation, batch number and application precaution labels.
Safety measures
MARITRANS contains isocyanates. See information supplied by the manufacturer. Please study the Safety Data sheet.
PROFESSIONAL USE ONLY.
Our technical advice for use, whether verbal, written or in tests, is given in good faith and reflect the current level of knowledge and experience with our products. When using our products, a detailed object-related
and qualified inspection is required in each individual case in order to determine whether the product and /or application technology in question meets the specific requirements and purposes. We are liable only for
our products being free from faults; correct application of our products therefore falls entirely within your scope of liability and responsibility. We will, of course, provide products of consistent quality within the scope
of our General Conditions of Sale and Delivery. Users are responsible for complying with local legislation and for obtaining any required approvals or authorizations. Values in this technical data sheet are given as
examples and may not be regarded as specifications. For product specifications contact our R+D department. The new edition of the technical data sheet supersedes the previous technical information and renders
it invalid. It is therefore necessary that you always have to hand the current code of practice.
* All values represent typical values and are not part of the product specification.