Spesifikasi Flow Meter

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 4

 FLOWMETER SENSOR OUTFALL CONDENSOR

JUMLAH 1 EA

Manufactured by: Teledyne ISCO


Model: ISCO LaserFlow Flow Meter (MCERTS)

38.01 x 26.21 x 56.7 cm


Size (HxWxL)
(14.96 x 10.3 x 22.32 in)
Weight 8.7 kg (19.2 lbs)
Conductive Carbon Filled ABS, SST,
Materials Conductive Kynar,
Anodized Aluminum, UV-Rated PVC
Cable Lengths 5, 10, 15, or 23 m
Enclosure IP68
CE EN61326; FDA CDRH
Certifications
21CFR1040; IEC 60825-1
Laser Class Class 3R Laser Product
Temperature Operating: 0 to 60 °C (32 to 140 °F)
Range Storage: -40 to 60 °C (-40 to 140 °F)
Input voltage: 8 to 26 VDC
Power Required
12VDC Nominal
±5% of Reading. (Typical, under normal
Flow Accuracy
flow conditions)
Velocity
Technology Non-Contact Laser Doppler
Measurement
-4.6m/s to 4.6 m/s (-15 ft/s to 15 ft/s)
Range
Maximum Depth 3m (10 ft)
Bi-Directional
Measurement
a
Accuracy ±0.5% of reading ±0.03 m/s (0.1 ft/s)
Minimum Velocity 0.25 m/s (0.8 ft/s)
Level
Technology Non-Contact Ultrasonic
Measurement 0 to 3 m (0 to 10 ft)
Range from measurement point
Accuracy ±0.006 m (0.02 ft) at less than or equal to 1 ft level change;
@ 22 °C (72 °F) ±0.012 m (0.04 ft) at greater than or equal to 1 ft level change
Temperature ± 0.0002 x D (m) per degree C
Coefficient within ± 0.00011 x D (ft) per degree F
compensated (Where D = Distance from transducer to
range liquid surface)
Beam Angle 10° (5° from center line)
Ultrasonic Signal 50KHz
Optional Secondary Measurement:
TIENet™ 350 AV Sensor
Probe Size 19 x 33 x 152 mm
(HxWxL) (0.75 x 1.3 x 6.0 in)
Sensor: Epoxy, chlorinated CPVC, SST
Materials
Cable: UV-Rated PVC
Certifications CE EN61326
Temperature
0 to 70 °C (32 to 158 °F)
Range
Velocity
Submerged Continuous Wave Doppler
Technology
Ultrasonic
Measurement
-1.5 to 6.1 m/s (-5 to 20 ft/s)
Range
Velocity
Bi-Directional
Measurement
±0.03 m/s (±0.1 ft/s) from -5 to 5 ft/s
Accuracy ±2% of reading from 5 to 20 ft/s,
Uniform velocity profile
Minimum Depth 25 mm (0.08 ft)
Frequency 500 kHz
Level
Submerged Differential Linear Pressure
Technology
Transducer
Measurement
0.01 to 3.05 m (0.033 to 10 ft)
Range
± 0.01%FS
Accuracy
b
Maximum
10.5 m (34 ft)
Depth
Stability ±0.007 m/yr (±0.023 ft/yr)
a. Turbidity > 20 NTU; Distance from liquid surface to bottom of sensor < 48 inches.
b Maximum non-linearity, hysteresis, & temperature error from
actual liquid level.
 FLOW METER (KHUSUS LIMBAH), LOKASI NET POND (INLET 2” OUTLET 1.5”)
 FLOW METER (KHUSUS LIMBAH), LOKASI CLARIFIER ASH YARD (INLET 2” OUTLET 3”)

JUMLAH 4 EA

Manufactured by: Siemens-Milltronics


Model: MAG 5100W Magflo Meter

Applications

Water abstraction
Water treatment
Water distribution network (leak detection management)
Custody transfer water meters
Irrigation
Waste water treatment
Filtration plant (e.g. reverse osmosis and ultra filtration)
Industrial water applications

Measuring Range 0 to 10 m/s


Nominal Sizes From DN 25 to DN 2000 (1” to 78”)
Accuracy 0.2 % ±2.5 mm/s
Operating Pressure Max. 16 bar (Max. 150 psi)
Ambient Temperature From -40 to 70 °C (-40 to 158 °F)
Medium Temperature From -10 to 70 °C (14 to 158 °F)
EPDM
Liners NBR hard rubber
Ebonite hard rubber
Hastelloy C-276
Electrodes
Built-in grounding electrodes
Carbon steel, with corrosion resistant
Material
two-component epoxy coating
EPDM: WRAS, NSF/ANSI Standard 61,
DVGW 270,
Drinking Water Approvals ACS and BelgAqua
NBR: NSF/ANSI Standard 61, WRAS
Ebonite: WRAS
OILM R 49
Custody Transfer Approvals
MI-001
General Approval MCERTS Sira Certificate No. MC080136/00