Assignment 3 PDF
Assignment 3 PDF
Fall 2023
Assignment No. 3
Due Date: 30/12/2023
Problem No. 1
Fig below shows the single line diagram of a simple 3 bus power system. Data for the system are
given in Table 1 and 2
a. Using the Gauss-Seidel method, determine the phasor values of the voltage at buses 2 and
3.
Problem No. 2
Repeat the Problem 1 considering bus 2 is PV bus. Use same data as given in tables 1 and 2. Fig
below shows the system to be considered now.
Problem No. 3
In the two-bus system shown in fig, bus 1 is a slack bus with pu. A load of 100 MW
and 50 MVAR is taken from bus 2. The line impedance is pu on a base of 100
MVA. Using Newton-Raphson method, obtain the voltage magnitude and phase angle of bus 2.
Start with an initial estimate of pu and Perform two iterations.
Problem No. 4
Fig below shows the single line diagram of a simple 3 bus power system with generation at buses
1 and 2. The voltage at bus 1 is per unit. Voltage magnitude at bus 2 is fixed at 1.05 pu
with a real power generation of 400 MW. A load consisting of 500 MW and 400 MVAR is taken
from bus 3. Line admittances are marked in per unit on a 100 MVA base. For the purpose of hand
calculations, line resistances and line charging susceptances are neglected.
a. Show that the expression for the real power at bus 2 and real and reactive power at bus 3
are
b. Using the Newton-Raphson method, start with the initial estimates of and
, and keeping per unit, determine the phasor values of and .
(Perform only two iterations)
c. Find the slack bus real and reactive power after second iteration
d. Determine the line flows and line losses after second iteration.