SERVING THE GAS INDUSTRY WORLDWIDE

Technical Product Information

ULTRASONIC FLOWMETER USZ 08

Next Generation

RMG MESSTECHNIK GMBH


ULTRASONIC FLOWMETER USZ 08

Short description Measuring accuracy


Since its approval in 2001, the USZ 08 ultrasonic flow- Path geometry, 6-path technology and high signal
meter has been further developed on a continuous basis. amplitudes endow the gas meter with high measuring
On the front page, the evolution becomes evident. How- accuracy. Additionally, a two-stage error curve linea-
ever, it has not only been optical, but above all technical. rization can be performed.
In the meantime, sensors and electronics which were
originally bought in from external sources have been
Ultrasonic electronics
replaced by RMG's own developments. Next in line of
The new USE 09 ultrasonic electronic system features a
development objectives comes the approval of the
display, so that meter readings and parameters can be
USZ 08 with an integrated totalizer in accordance with
read directly from the gas meter. Pulse outputs are also
the European Measuring Instruments Directive (MID).
available.

Case and installation


The face-to-face length of the USZ 08 ultrasonic flow- Ultrasonic control computer
meter has been reduced to 3 DN. As the sensor sleeves In conjunction with the ERZ 2000, a combined ultrasonic
are also shorter now, the case has become more control computer and gas volume corrector, there are a
compact in all. number of other functions available, such as archives and
Installation conditions: DSfG and TCP/IP interfaces.
• Inlet pipe: 10 DN without or 5 DN with a
perforated-plate flow straightener Diagnostic USZ software
• Outlet pipe: 3 DN Using the new diagnostic USZ software, it is possible,
• Pipe diameter: Inside diameter of the meter -2%/+5% among other things, to read out and change parameters,
represent measured values graphically and create test
6-path technology certificates.
As to the USZ 08 ultrasonic flowmeter, RMG continues to
focus on the 6-path technology which has several Technical specifications
substantial advantages, such as Measuring uncertainty: ± 0.25% of the measured value
• insensitivity - the special arrangement of acoustic (6-path design)
paths reduces the influence of flow disturbances; Degree of protection: IP 65
• redundancy - even if two acoustic paths fail, measure- Temperature range: -20°C to +55°C
ments continue to conform to custody transfer require- -40°C to +80°C on request
ments; Pressure classes: PN 40 to PN 160 / ANSI 900
• transferability - the more acoustic paths available, the Explosion protection: II2 G EEx de IIC T5/T6
better the results achieved on the test stand can be Power supply: 24 V/DC
transferred to real measurement conditions.

Measuring ranges and dimensions


DN Measuring range Designs Dimensions Max. weight 1)
mm (in) m3/h mm kg
Qmin Qmax Length Width Height 2)
100 ( 4") 13 1000 3 -path design 300 340 320 165
150 ( 6") 20 2500 3 -path design 450 430 350 215
200 ( 8") 40 4000 6 -path design 600 500 385 280
250 (10") 65 6500 6 -path design 750 580 425 370
300 (12") 80 10000 6 -path design 900 660 450 500
400 (16") 130 16000 6 -path design 1200 820 500 900
500 (20") 200 25000 6 -path design 1500 1000 560 1400
600 (24") 320 40000 6 -path design 1800 1140 620 2000
1) depending on the pressure class 2) measured from the centerline of the pipe Larger gas meters on request

RMG MESSTECHNIK GMBH • Otto-Hahn-Str. 5 • 35510 Butzbach (Germany) • Phone: +49 (0)6033.897-0 •