Kee 01
Kee 01
AC Ammeter panel
ELECTRICAL TRAINER - 0-5A AC Ammeter
- Selector switch for 3 phase current
measurement.
FWD/REV, STAR/DELTA Switch panel
- FWD/REV, 3 pole 3 way switch, 6A/440V
- Star/Delta switch 3 pole, 3 way, 6A/440V
Lamp Load panel
- 3 Lamp Load socket with 15/40/60/100W
Bulb.
- On/OFF toggle should be provided for
each bulb socket.
1 Ph Motor, Alternator & Sync Panel
KEE-01 Electrical Trainer is a rouged training - 1ph 230V/2A & 230V/4A AC output
system for the Electrical laboratories mounted supply.
on Allumunium profile rack with sturdy table Consist of 1 Phase AC/DC Resistive Load
top flat panel. Each panel has ABS molded panel
plastic sturdy enclosure with 4mm shrouded - 750E/600E/300E/212E/162E/
connectors showing circuit diagram & its 125E/112E/100E 200W Load.
connection tag numbers for easy - 9 Way Selector switch for selection of
understanding and connections. The product load resistors
helps you to get fully acquainted with the Table Top 1 Phase Transformer 500VA
basic concepts and functioning of an Electrical (2Nos)
Trainer. - Transformer with 500VA Primary Input
(0-230V) and secondary Output (200V)
Specifications
Trainer control panel is provided in Table Top 3 Phase Transformer 500VA
40X40mm Aluminum profile rack with sturdy - 3ØTransformer with 300VA RYB Primary
table top flat panel. Input (230V/415V) and 3Ø 300VA RYB
Secondary Output (230V/415V)
It has 8 no’s of ABS plastic panel mounted
on the aluminum rack with mimic diagram of Accessories:
components Set of Shrouded Cables
All input & output are terminated in 4mm Set of Manuals with Experiments.
shrouded connector and 4mm banana cable Demo CD showing Experiments
is provided for experiments.
Optional Accessories:
3phase DOL starter 4pole MCB, contractor
& relay panel Variac
- 4 pole MCB of 415 V/4A - 0-270V /2A Variac (1 phase Transformer)
- DOL 9A Contactor with 230V / 50 Hz / - 0-470V /6A Variac (3 phase Transformer)
11VA COIL Working Table (KWT-01)….1 No
- Bimetallic thermal O/L relay with range Multimeter … 1 No
1.4A - 2.3A Tool Kit… 1 No
- R-Y-B Input display Indicators. Experiment List
- Manual start / stop with local trip contact 1. Study of Manufacturing Quality Tests.
3 phase multifunction meter Panel (2 Nos) 2. Study of Insulation resistance test.
- Bidirectional Multifunction 3. Study of Single Phase Transformer and
- 3 Phase ¾ wire, 415V, CT Input 5A calculate it’s Turn’s Ratio
- LCD/LED display, Aux supply 230V, 4. Study the Polarity Test of Single Phase &
45-65 Hz, 5W 3 phase Transformer
- V, A, Hz, Pf, KVA, KW, KWH 5. Study of Performance tests.
- Modbus RTU RS485 connections 6. Study the Open Circuit Test of Single
Phase & 3 phase Transformer
AC Voltmeter panel 7. Study the Short Circuit Test of Single
- 0-500V AC Voltmeter Phase & 3 phase Transformer
- Selector switch for 3 phase voltage 8. Scott connection : Using 2 nos. of 1 ph.
measurement. Transformer
9. Study of Load regulation test.
10. Study of Back to back test (sumpner test)
11. Study & measure winding Temperature of
the Single Phase & 3 phase Transformer
12. Measurement of winding resistance by
DC V-I method.
13. Study the working of Single Phase & 3
phase Transformer with load & Effect of
type of load on transformer output
waveform
14. Study the working of Single Phase
Transformer and measure secondary
output Voltage in series & parallel
connection
15. Study of Scott connection for 3phase to 2
phase conversion
16. Three phase transformers - basic
configurations — their effect on capacity
utilization regulation.
17. Study of Phasor Groups in 3 Phase
Transformer connections
18. Study of using Tertiary winding on 3 ph.
transformers for suppressing harmonics.
19. Study of Load regulation, efficiency &
Temp. rise test on 3 ph. Transformers
20. Study of Manufacturing Quality Tests on 3
phase transformers
21. Determination of zero sequence
reactance of 3 ph. transformer.
22. Determination of equivalent circuit of 3 ph.
Transformer
23. Self & mutual inductance measurement of
1 phase transformer
24. Determination of equivalent circuit of 3 ph.
transformer.
25. Effect of variety of three phase
connections on regulation and current
carrying capacity of transformers.
26. Harmonic cancellation & shift in phasor
diagram due to different connections,
Working of Teaser transformer
27. Back to back test (sumpner test) on two
identical single phase transformers.