Ask 800

The document describes the ASK 800 transmitter with remote seal for level and differential pressure measurement. It has a measuring range of 10 mbar to 40 bar, uses proven and mature technology combined with a microprocessor-controlled electronic. The remote seal is directly mounted to a process flange and uses an isolated diaphragm to measure differential pressure and convert it to a 4-20 mA output signal. The transmitter provides intelligent functions like PID control, communication via HART protocol, and corrosion resistant materials for remote seal wetted parts.

Uploaded by

eletrica.sme
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
620 views10 pages

Ask 800

The document describes the ASK 800 transmitter with remote seal for level and differential pressure measurement. It has a measuring range of 10 mbar to 40 bar, uses proven and mature technology combined with a microprocessor-controlled electronic. The remote seal is directly mounted to a process flange and uses an isolated diaphragm to measure differential pressure and convert it to a 4-20 mA output signal. The transmitter provides intelligent functions like PID control, communication via HART protocol, and corrosion resistant materials for remote seal wetted parts.

Uploaded by

eletrica.sme
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

Contrans P ASK 800

HART Transmitter with Remote Seal for Level and


Differential Pressure
Span: 10 mbar to 40 bar
(1 kPa to 4,000 kPa)

10/15-6.35 EN

(20857.bmp)

n Isolation between Process and Transmitter with Measuring The transmitter ASK 800 combines proven, mature technology wi-
Media having: • High Temperatures and Viscosities •Corro- th a trend-setting microprocessor controlled electronic.
sive Ingredients, a Tendency to Polymerization It is based on a proven, highly-stable measuring mechanism, on
n Prevention of Deposits in the Process Connection Flanges by which a remote seal with flange is fitted directly onto on side. The
internal sensing diaphragm is slightly deflected corresponding to
Extended Remote Seals
n Mounting to various DIN or ANSI Flanges
the differential pressure present between the remote seal and the

n
equalizing side and converted into an electrical signal by the elec-
Microprocessor technology tronics. Apart from a high accuracy with an almost complete com-
n High turn down ratio 30 : 1 pensation of ambient influences, both measuring mechanism and
n Digital communication using the "HART"-Protocol without
electronic provide a substantial increase in functionality.The digital
indicator can be so configured that the measured value can be il-
disturbing the output signal 4...20 mA
n Lower range value, span and damping are externally adjust-
lustrated as a physical unit, percentage value or current. In additi-
on the measuring mechanism temperature can be indicated. The
able process wetted parts of the remote seal can be selected from dif-
n Transfer response configurable: ferent materials such as stainless steel, Hastelloy C, Monel or tan-
• linear • freely programmable • PID-controller talum and others, depending upon the required resistance to
n "Intrinsic Safety" or "Flameproof Enclosure" explosion protec-
corrosion.
Various filling liquids, for example for the food and beverage indu-
tion or mounting on "Zone 0"
n
stry, complete the spectrum of applications. The Transmitter ASK
E.M.C. according to IEC 801 800 is thus an efficient, intelligent element, a must for every type of
automation.
Data Sheet
Transmitter ASK 800 with Remote Seal
for Level and Differential Pressure 15-6.35 EN

Technical Data

Measuring Mechanism Max. permissible voltage ripple of the power supply during the
communication:
Measuring limits
• 7 Vpp at 50 Hz ≤ f ≤ 100 Hz
-100% and +100% of the max. span
• 1 Vpp at 100 Hz < f ≤ 200 Hz
Lower range value
• 0.2 Vpp at 200 Hz < f ≤ 300 Hz
Continuously adjustable between the measuring limits
The following can, for example, be configured:
Span
Digital indication of process pressure, temperature, per-
Arbitrary - continuously adjustable within the range limits.
centage value, current, arbitrary process variables
The adjusted span must not to be lower than the minimum
Damping
span. Smallest span: 10 mbar.
Transfer function
2...60 mbar (0.2...6 kPa)
Alarm signalling Imin/Imax
13.34...400 mbar (1.334...40 kPa)
PID Controller; adjustment with five parameters;
0.0834...2.5 bar (8.34...250 kPa)
- Setpoint w
0.534...16 bar (53.4...1,600 kPa)
- Proportional gain Kp
1.334...40 bar (133.4...4,000 kPa)
- Reset time Tn
Characteristic
- Derivative gain KD
Linear, rising or falling Freely programmable
- Derivative action time TD
Over-ranging limit
Write-over of parameters can be prevented by the interlock
Each side may be over-loaded up to 100% of the nominal-
switch. All stored data is secured even in the event of power
pressure
supply failure.
Measuring chamber volume (equalizing side)
A detailed description of all functions can be found in the Instruc-
approx. 14 cm3
tions 42/15-910 EN.
Isolating diaphragm (equalizing side)
1.4404 (≡316 L stainless steel) General and Safety Data
Blanking plug Ambient Conditions
1.4571 (≡316 Ti stainless steel)
Ambient temperature range
Power Supply -40°C...+80°C
Transmitter operating voltage Storage and transport temperature range
UB,max= DC 45 V UB,min= DC 11.5 V -50°C...+80°C
Humidity
Output signal ≤95%, annual mean, condensation permissible
4...20 mA
Output signal limits Amplifier Enclosure, Mounting, Weight
Imin 3.5 mA, Imax 22.5 mA Material
Standard adjustment: Imin 3.8 mA and Imax 20.5 mA Die cast copperfree aluminium (GD-AlSi)/polycarbonate
Load R Protective varnish
U 11.5V US Supply voltage Epoxy resin, gravel-grey, RAL 7032
R ≤ S kΩ Degree of Protection
I Imax 20...22.5mA (adjustable)
max
IP 65 (jet waterproof) according to EN 60 529
Digital Communication (≡ NEMA standard type 4)
Standardized communication protocol "HART" 5.1 Type of Mounting / Sealing
Minimum load for communication: 250 Ω Flanged to side of container
Recommended lead-length for communication: Seal type: non metallic
• screened multi-wire: max. 1.5 km Weight
• screened two-wire: max. 3 km Approx. 12 kg
Functional Diagram ASK 800 with Remote Seal
Measuring capsule Overload diaphragm
Remote seal ( HP) Sensing diaphragm
MICROPROCESSOR-
based electronics

4...20mA
DC 11.5...45V

TEST
INSTRUMENT

Equalizing side ( LP) Sensor body


M01060E1.EPS

Page 2 of 10 08.2000
Data Sheet
Transmitter ASK 800 with Remote Seal
for Level and Differential Pressure 15-6.35 EN

Technical Data

Application limits: permissible temperature/minimum pressure


The pressure has to be linearly interpolated between the stated temperatures
Filling-Liquid Silicone Oil Carbon Fluoride Distilled Water Vegetable Oil Vac.-proof Design
Identification IB L D PF IC
Density at 20 °C (kg/m3) 924 1880 998 920 1055
Operating Temperature (°C) -30...+250 -30...+150 +5...+70 -10...+250 -30...+200
Static Pressure (mbar abs.)
at 20 °C > 500 > 1000 > 1000 > 500 > 5
100 °C > 500 > 1000 --- > 1000 > 25
150 °C > 500 > 1000 --- > 1000 > 38
200 °C > 750 --- --- > 1000 > 50
250 °C > 1000 --- --- > 1000 ---

Transient Response at reference conditions Explosion protection, Certification


(see Instructions for further data)(1.4404 isolating diaphragm material, silicone for Zone 0
oil filling liquid).All values are limit values and refers to the output span. The
effects identified with a * are with reference to the measuring range and are to Definition of "Zone 0":
be multiplied by the turn-down factor. The ratio range/calibrated span should "Zone 0" includes all areas in which, permanently or for long periods of
be as small as possible. time, a dangerously explosive atmosphere exists.
Conformity1) including hysteresis and dead band Type Approval
terminal-based 0.1 % according to VbF "Zone 0". Gas group IIC and for flammable liquids of the
Hysteresis 0.05 % hazard classes AI, AII or B.
Power supply Instrument Mounting
voltage effect per volt 0.005 % The measuring mechanism can be directly connected onto "Zone 0"
Type Approval Certificate: PTB No. III B/S-1949
The following specifications are valid for a linear transfer function. The effect
PTB No. Ex-93.C.4004 (EEx ia IIC T6)
appearing at the output with non linear transfer functions is dependent on the
Type Approval: 08/PTB No. III B/S-1949
function and is to be calculated accordingly
for Zone 1
Static pressure effect per 100 bar When the transmitter is installed in "Zone 1", the type of protection "Intrin-
Measuring ranges ≤ 2.5 bar sic Safety EEx ia" is sufficient.
on zero 0.2 % Explosion protection Intrinsic Safety "i"
on span 0.1 % Identification Code (DIN EN 50 014): EEx ia IIC T6
Measuring ranges ≥ 16 bar Type Approval Certificate: PTB No. Ex-93.C.4004
on zero 0.5 % Connected to an intrinsically safe current circuit with the highest values:
on span 0.75 %
Ambient temperature effect acc. to DIN 16 086 Tempera- Umax Imax Pmax Max. ambient
Thermal change (-20°C...+60°C) ture class temperature
2)
on zero 0.1 % +0.6 mbar/10K
on span 0.1 % +0.1%/10K 2) T6 45 V 130 mA 0.5 W 40 °C
Temperature coefficient (-40°C...+80°C) 3) T5 45 V 130 mA 0.8 W 40 °C
on zero 0.05 %/10K +0.6 mbar/10K2)
on span 0.15 %/10K 2) T4 45 V 130 mA 1.0 W 80 °C
Long-term drift within 6 months 0.05 % T4 45 V 130 mA 1.2 W 60 °C
Rise time acc. to DIN 16 086
internal capacitance Ceq ≤ 0.010 µF, internal inductance is negligably small
dependant on range and turn-down factor 0.15...1.6s
Type of protection: Flameproof Enclosure "d"
additional adjustable time constant 0...60s
1)
Identification Code (DIN EN 50 014):EEx d IIC T6
Additionally with turn-down factor >1:10
Measuring range Type Approval Certificate: PTB No. Ex-91.C.1077
± (0.005 × 0.05) %
adjusted span Operating conditions: max. ambient temperature 75°C
2)
Measuring mechanism and remote seal with same temperature BASEEFA Type N Approval
3)
With carbon fluoride filling liquid -20°C...+80°C Ex N IIC T5 (Tamb: - 40 °C to + 80 °C)
Electrical Connections Functional Diagram-Communication
Cable gland or One Han 8U plug (option)
female thread (standard)
+ +
p
UB US
+# – –
+ IA + FSK
AS 800 Power supply
TEST

Contrans P
~181

FSK-Modem
~76

Screw terminals for


0.5...2.5 mm 2- wires Plug connection diagram
34
IBIS
Socket-insert RS 232C
1 2 (view on
sockets) M01058E2.EPS
M01063E1.EPS +

08.2000 Page 3 of 10
Data Sheet
Transmitter ASK 800 with Remote Seal
for Level and Differential Pressure 15-6.35 EN

Ordering Data

To order, the order number and the data of the adjustable values: lower and upper range values, will suffice.

Transmitter ASK 800 Order No. 1 5 9 . . - 2 -

Nominal pressure

PN 100 (10 MPa) 316 Ti St.St. (1.4571) . . . . . . . . . . . . . . . 43


Measuring range 1 5 9 9 0 -
Order No. 2 -
0 . . . 60 mbar (6 kPa)  ........................... ... . . . . . . . . . 10
0 . . . 400 mbar (40 kPa)  adjusted from ...to...mbar/kPa1) . . . . ... . . . . . . . . . 14
0 . . . 2.5 bar (250 kPa)  ........................... ... . . . . . . . . . 18
Measuring range Order No. 1 5 9 6 3 - 2 -
0 . . . 16 bar (1,600 kPa) adjusted from ...to...bar/kPa1) . . . . . . . . . . . . . . . . . 36
0 . . . 40 bar (4,000 kPa) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Isolating diaphragm material


316 St.St. (1.4404) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 050

Flange-O-rings
Buna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 060
Viton (restricted operating temperature -18°C...+80°C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
PTFE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161

Process connection (equalizing side)


Flange connection and 1/4-18 NPT top and bottom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 064
Process connection acc. to DIN 19213 and 1/4-18 NPT top and bottom (for PN100,316Ti St.St.2))191

Filling liquid
Silicone oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 070
Carbon fluoride (restricted operating temperature -20°C...+80°C) . . . . . . . . . . . . . . . . . . . . . . 137

Output signal
4 . . . 20 mA, linear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 023
4 . . . 20 mA, Characteristic acc. to table of values, max. 22 pairs: Input(%);Output(%) . . . . 221

Electrical connection
One Pg 13.5 cable gland . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 044
Two Pg 13,5 cable glands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268
Two 1/2-14 NPT female threads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270
One plug connector (Han 8U) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272
Order No. 1 5 9 . . - 2 - / / / ...

If necessary, Code Nos. are to be suffixed to the Order No.

1)
Possible units: mbar, bar, Pa, kPa, mmH2O, mmHg, psi, g/cm2, kg/cm2, inches H2O, inches Hg, feet H2O.
2)
Other variations upon request.

Page 4 of 10 08.2000
Data Sheet
Transmitter ASK 800 with Remote Seal
for Level and Differential Pressure 15-6.35 EN

Additional Ordering Data for Instrument Options (Code Nos.)

Code Nos. can be continuously suffixed to the Order No.

Instrument Options Code No.

Ex-design: EEx ia IIC T6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 557


EEx d IIC T6 (only when combined with Order No. 270) . . . . . . . . . . . . . . . . . . . . . 558
for "Zone 0" (only combined with Code No. 557) . . . . . . . . . . . . . . . . . . . . . . . . . . 264
BASEEFA Type N Approval, Ex N IIC T5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274

Analogue indicating instrument (Scale markings: 0...100 % linear) Normal or Ex "i" design . . . . . . . . . 206
Digital indicating instrument: Normal or Ex "i" design:
(indicates %, however with Code No. 415 process pressure) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244
Digital indicating instrument: Ex "d" design:
(indicates %, however with Code No. 415 process pressure) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
Scale indication... (please define value: e.g. 0...15 m1); 4...20 mA proportional; only combinable
with Code No. 244/245, not with Code No. 415) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 416

PID Controller,Parameter: nominal value [%]; Kp (0...40); Tn [s] (0.1...3600); KD (0...40); TD [s] (1...3600)2) 415
Alarm signalling with 3.6 mA (Standard: 21 mA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 417
Max. output current... (please state value 20...22.5 mA; Standard: 20.5 mA) . . . . . . . . . . . . . . . . . . . 418
Min. output current... (please state value 3.5...4 mA; Standard: 3.8 mA) . . . . . . . . . . . . . . . . . . . . . . . 420
Electrical damping TG=... (please state value to be adjusted: 0...60 s) . . . . . . . . . . . . . . . . . . . . . . . . 259

Tagging (on Type plate, max. 32 characters) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205


Tagging on Tie-on plate (stainless steel, max. 32 characters) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202

Flange screws - stainless steel (not with carbon steel flanges) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193

Documentation
Instructions (state total number of copies)3)
German (42/15-992, no details required for one copy) . . . . . . . . . . . . . . . . . . . . . . . . . (...copies) Z2D
English (42/15-992 EN, Order-No. always required) . . . . . . . . . . . . . . . . . . . . . . . . . . . (...copies) Z2E
French (42/15-992 FR, Order-No. always required) . . . . . . . . . . . . . . . . . . . . . . . . . . . (...copies) Z2F

Digital Communication: User Interface "IBIS" (Data Sheet 15-6.96 EN), FSK-Modem (Data Sheet 15-6.97 EN)

Mounting Accessories see Data Sheet 15-8.98 EN (e.g. fixing screws, O ring seals)
Certificates see Data Sheet 15-6.99 EN

1)
Possible units: pressure units, as listed under "adjusted from... to..."; m, cm, mm, inches, feet, m3, l, barrels, gallons, yard3,
inches3, feet3, g, kg, t, pounds, short tons, long tons (further units see Technical Information: B 92 M 508 V)
2)
To optimise the process it is necessary to have the additional facilities available with IBIS and a modem. When no values
stipulated-standard values will be programmed i.e. setpoint = 50% and Kp = 1. Tn, KD and TD are switched off (0).
3)
One copy without charge

Scope of Supply
1 Instructions Supplied against special order:
1 Blanking plug Connecting pipe unions, flanges, valves, manifolds, remote seals,
1 Instrument socket with plug connector Power supply e.g. TZN 128 (Data sheet 18-8.39 EN),
Spare Parts Transmitter ASK.

08.2000 Page 5 of 10
Data Sheet
Flush Diaphragm Remote Seals DN 80 / ANSI 3"
15-6.35 EN

Ordering Data

Relevant Code Nos. can be continuously suffixed to the transmitter Order No.

Flush diaphragm remote seals DN 80 / ANSI 3" Code No.

Mounting
Direct mounting (on ASK 800 without capillary tube) . . . . . . . . . . . . . . . . . . 729

Material: Diaphragm and Body


sealing surface
1.4404(316 L st.st.) 1.4404 . . . . . . . . . . . . . . . . . . . . . . . . . . 605
Hastelloy C 1.4006 (410 st.st.) . . . . . . . . . . . . . . . . . . . . . . 606
Monel 1.4404 . . . . . . . . . . . . . . . . . . . . . . . . . . 607
Tantalum 1.4006 . . . . . . . . . . . . . . . . . . . . . . . . . . 608

Sealing surface1): Form E (DIN 2526) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 062


Form V 13 (DIN 2513) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 643
Form N (DIN 2512)(only with Code No. 605) . . . . . . . . . . . . . . . . . . . . . . . . 644

Form RF (ANSI B 16.5)


150 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 604
300 psi up to 1500 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 724

Form RJF (ANSI B 16.5)(only with Code No. 605)


300 up to 600 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 646
1500 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 645

with blank flange (DIN 2527) stainless steel 1)


Pressure rating PN 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 786
PN 40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 787
PN 64 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 788
PN 100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 789

with blank flange (ANSI B 16.5 DN 3"-RF) stainless steel 1)


Pressure rating 150 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 790
300 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 791
600 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 792
1500 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 793

Filling liquid
Silicone Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 074
Carbon Fluoride . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 687
Distilled Water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 688
Vegetable Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 673
Vacuum-Proof Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 739

Additional Mandatory Code Nos.

with FEP coating (medium temperature ≤ 150 °C, only with Code Nos. 605/606) . . . . . . . . . . . . . 662
Ex Design for "Zone 0" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 689

(Add the remote seal Code Nos. ... / / / ...


Order No. to the transmitter Order No.) 7 2 9

1)
The ordering data for DIN und ANSI cannot be combined with each other.

Page 6 of 10 08.2000
Data Sheet
Extended Diaphragm Remote Seals DN 80 / ANSI 3"
15-6.35 EN

Ordering Data

Relevant Code Nos. can be continuously suffixed to the transmitter Order No.

Extended diaphragm remote seals DN 80 / ANSI 3" Code No.

Mounting
Direct mounting (on ASK 800 without capillary tube) . . . . . . . . . . . . . . . . . . 729

Material: 1.4404≡316 L st.st.; 1.4571≡316 Ti st.st.


Extension and sealing surface
Diaphragm Form E, V13 Form N Form RJF
and RF Ext./seal.surf.
1.4404 1.4571/1.4404 1.4571/1.4404 1.4571/1.4404 . . . . . . . . . . . 640
Hastelloy C Hastelloy C - - . . . . . . . . . . . . . . . . 641
Hastelloy C 1.4571 - - . . . . . . . . . . . . . . . . 642

Extension length: 50 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 647


100 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 648
150 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 649

Sealing surface1): Form E (DIN 2526) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 062


Form V 13 (DIN 2513) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 643
Form N (DIN 2512)(only with Code No. 640) . . . . . . . . . . . . . . . . . . . . . . . . 644

Form RF (ANSI B 16.5)


150 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 604
300 psi up to 1500 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 724

Form RJF (ANSI B 16.5)(only with Code No. 640)


300 up to 600 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 646
1500 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 645

with blank flange (DIN 2527) stainless steel 1)


Pressure rating PN 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 786
PN 40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 787
PN 64 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 788
PN 100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 789

with blank flange (ANSI B 16.5 DN 3"-RF) stainless steel 1)


Pressure rating 150 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 790
300 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 791
600 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 792
1500 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 793

Filling liquid
Silicone Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 074
Carbon Fluoride . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 687
Distilled Water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 688
Vegetable Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 673
Vacuum-Proof Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 739

Additional Mandatory Code Nos.

Ex Design for "Zone 0" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 689

(Add the remote seal Code Nos. ... / / / ...


Order No. to the transmitter Order No.) 7 2 9

1)
The ordering data for DIN und ANSI cannot be combined with each other.

08.2000 Page 7 of 10
Data Sheet
Transmitter ASK 800 with Remote Seal
for Level and Differential Pressure 15-6.35 EN

Dimensional Diagrams

Errors and omissions excepted. All dimensions in millimeters (mm). Seals and fixing materials not supplied.
a b ~294

80
10
79 2)

DIN

ød3
ød2

ød4

105
øK
øD
Contrans
ANSI

~28
108
~161 1)

34
4 6 12 13
Design with
extended diaphragm Form V13 Sealing Surface
Ext. length
50/100/150
mm c b
a
90

ø 138

ø 120
7
1
ød3
ød1

ød4
øK
øD
41.3

3
~200 1)

M 0 10 6 4 E 1.E PS
5

9 12 13

ø 82 Remote Seal Dimensions


11 8 Sealing surface a c ∅d1
3)
∅ d2 ∅ d3
Form E (DIN 2526)
19 17 76.1 78 138
Form RF (ANSI B 16.5)
Form V 13 (DIN 2513)
DN 80 Form N (DIN 2512) 19 17 76.1 78 138
or
ANSI 3" Ring Joint Form RJF 22 22 76.1 78 146
1 1/4-18 NPT female thread. (300/600psi)(ANSI B 16.5)
2 Thread for fixing screws: 7/16 UNF, 16 mm deep. Ring Joint Form RJF 22 22 76.1 78 168
Minimum screw-in length is 12mm. (1500psi)(ANSI B 16.5)
Whith flange acc. to DIN 19 213: M10, Minimum screw-in
Flange Connection Dimensions
length acc. to DIN 19 213.
3 60 x 32mm oval flange. Nominal Screws *)
4 Electrical connections: Pg 13.5 cable gland bottom or ∅K ∅ D ∅ d4
pressure Number Thread b
two glands top and bottom or 1/2-14 NPT femal threads on
top and bottom or plug Han 8U bottom. PN 16/40 160 200 138 8 M 16 20/24
5 Type plate. DN 80 PN 64 170 215 138 8 M 20 28
6 Locking excenter (only with EEx "d"-version).
7 Measuring mechanism plate. PN 100 180 230 138 8 M 24 32
8 Enclosure cover (electr. connection/analogue instrument). 300 psi 168.3 209.5 127 8 M 20 28.6
9 Enclosure cover (connection for digital instrument). ANSI 3" 600 psi 168.3 209.5 127 8 M 20 31.8
10 Tie-on plate e.g. for tag number (optional).
11 Sealing plug. 1500 psi 203 266.7 127 8 M 24 47.6
12 Mating flange acc. to DIN/ANSI (not supplied). *) not supplied
13 Flat seal (not supplied). 1) with dig. indic. instrument +29 mm 2) with analogue indic. instr. +24 mm 3) +/-1.5%

Page 8 of 10 08.2000
08.2000 Page 9 of 10
ABB Automation Products GmbH Subject to technical changes.
Schillerstraße 72 Printed in the Fed. Rep. of Germany
10/15-6.35 EN 08.2000
D-32425 Minden
Tel. +49(0)571 830-0
Fax +49(0)571 830-1846
http://www.abb.de/automation

You might also like