3998 18-1037002021-00069 Rev4
3998 18-1037002021-00069 Rev4
3998 18-1037002021-00069 Rev4
DOCUMENT TITLE: BASE LOAD DIAGRAM FOR CONDENSATE LOADING ARMS 129C-61-Z-0001, 129C-61-Z-0002 AND
VAPOR RECOVERY ARM 129C-96-Z-0002
DATE :
This document and all information are confidential and may not be used, reproduced or distributed without prior authorization of Technip Energies.
Ce document et toutes ses informations sont confidentiels et ne peuvent être utilisés, reproduits ou distribués sans l’autorisation préalable de Technip Energies.
REVISION HISTORY
0 Creation. - C. TCHA
1 Page 4 Updated 350 kg/m3 by 35 MPa C. TCHA
1 Page 4 Added following note: C. TCHA
(*) Bolt description is according
to drawing "RP129C-1-51-0008-
0006 LPB30/31 Metering
Platform Miscellaneous Details"
1 Page 4 Added Title block as per Project C. TCHA
Title Block
2 Page 4 Updated note for concrete S50. C. TCHA
Updated calculated values.
3 All pages Replaced “Rev50 As Built” by C. TCHA
“Rev1 Approved For
Construction”
3 Page 4 Updated locations of holes of C. TCHA
baseplate.
Updated hole diameter value.
3 Page 5 New page regarding dummy C. TCHA
manifold base loads.
4 Page 5 Added plate thickness value. C. TCHA
Updated base plate view.
Added forces and moments on
the view of the dummy manifold.
4 5 Page 4 Added plate thickness value. C. TCHA
Added note for anchor bolt
details.
P Dead Weight : N (kg) 408100 (41700) 408100 (41700) (*) Bolt description is according to drawing "RP129C-1-51-0008-0006
LPB30/31 Metering Platform Miscellaneous Details"
B Lateral Center of Gravity : m 0.77 0.77
Fv Total Wind Force : N 72000 - 4 - For anchor bolt details (rods, whashers and nuts), refer to document 3998_18-1037002021-00035
Interface Drawing for LPG, Condensate, and Vapor Recovery Loading Arms (T.EN reference:
24001C21436501)
Av Height of Total Wind Force : m 9.18 -
Fsh Horizontal Seismic Force : N - 17426
Fsv Vertical Seismic Force : N - 5713
As Height of Center of Gravity : m - 7.28
Stored position
CONTRACTOR REVIEW COMMENTS DO NOT INDICATE EITHER RESPONSIBILITY OR LIABILITY FOR ACCURACY AND COMPLETENESS OF THIS DOCUMENT OR ALTER ANY
CONTRACTUAL TERMS AND CONDITIONS.
Locations of drilled holes on arm baseplate (compatible with each arm) DATE :
8 TOLERANCES GENERALES
(SAUF INDICATIONS CONTRAIRES)
7 GENERALES TOLERANCE
(UNLESS OTHERWISE SPECIFIED)
6
DIMENSION / DIMENSIONAL : N/A
5 13-Nov-2023 APPROVED FOR CONSTRUCTION
B P & Fsv
ANGULAIRES / ANGULARS : N/A
4 25-Sep-2023 APPROVED FOR CONSTRUCTION
Fv
RUGOSITE / ROUGHNESS : N/A
3 30-Aug-2023 APPROVED FOR CONSTRUCTION MATIERE / MATERIAL :
2 09-May-2023 APPROVED FOR CONSTRUCTION N/A
PLAN REF / REF DRAWING :
1 15-Feb-2023 APPROVED FOR CONSTRUCTION
-
Fsh
0 20-Dec-2022 CREATION / FIRST ISSUE
-
REV. DD/MM/YYYY DESCRIPTION ECN SIGN -
Rb
N/A LOADING SYSTEMS
A3
ROUTE DES CLERIMOIS
N/A
Rb
WWW.TEN.COM
measurements on Berth 31
DESSINE PAR / DRAWN BY : NUMERO DE PLAN / DRAWING NUMBER : FOLIO / SHEET :
C. TCHA
(Note : Weight and Load estimate +/- 5 %)
APPROUVE PAR / APPROVED BY :
D. JAULT
24BLDC21436502 4/5
CE DOCUMENT ET TOUTES LES INFORMATIONS QU'IL CONTIENT SONT LA PROPRIETE CONFIDENTIELLE ET EXCLUSIVE DE T.EN Loading Systems ET NE PEUVENT ETRE REPRODUITS, UTILISES DIVULGUES OU RENDUSPUBLIC SANS L'AUTORISATION EXPRESS DE T.EN Loading Systems.
THIS DOCUMENT AND ALL THE INFORMATION CONTAINED HEREIN ARE THE CONFIDENTIAL AND EXCLUSIVE PROPERTY OF T.EN Loading Systems AND MAY NOT BE REPRODUCED, USED, DISCLOSED, OR MADE PUBLIC IN ANY MANNER PRIOR TO EXPRESS WRITTEN AUTHORIZATION BY T.EN Loading Systems.
Plate Thickness : mm 20
Holes Diameter : mm 26
Anchor Bolts : Nb x mm 4xM24
UNIT / EQUIP. No :
129C-61-Z-0001/0002 - 129C-96-Z-0002
DOCUMENT TITLE:
BASE LOAD DIAGRAM FOR CONDENSATE LOADING ARMS 129C-61-Z-0001, 129C-61-Z-0002 AND VAPOR RECOVERY ARM 129C-96-Z-0002
CONTRACTOR REVIEW COMMENTS DO NOT INDICATE EITHER RESPONSIBILITY OR LIABILITY FOR ACCURACY AND COMPLETENESS OF THIS DOCUMENT OR ALTER ANY
CONTRACTUAL TERMS AND CONDITIONS.
500 mm
DATE :
FZ
MZ 4 13-NOV-2023 Approved For Construction CTC DJA ARA
500 mm 400 mm 3 25-SEP-2023 Approved For Construction CTC DJA ARA
2 30-AUG-2023 Approved For Construction CTC DJA ARA
1 09-MAY-2023 Approved For Construction CTC DJA ARA
0 15-FEB-2023 Approved For Construction CTC DJA ARA
B 20-DEC-2022 Issued For Review CTC DJA ARA
Z
FY Rev. Issue Date Revision Description Prepared By Reviewed By Approved By
ARM SIDE
MY Y FX
400 mm 8 TOLERANCES GENERALES
(SAUF INDICATIONS CONTRAIRES)
X 7 GENERALES TOLERANCE
(UNLESS OTHERWISE SPECIFIED)
6
MX BASE PLATE DETAIL 5 13-Nov-2023 APPROVED FOR CONSTRUCTION
DIMENSION / DIMENSIONAL : N/A
SEA SIDE
BASE LOAD DIAGRAM
A3
ROUTE DES CLERIMOIS
89107 SENS CEDEX FRANCE - CS 10705
ECHELLE / SCALE :
P: +33 3 86 95 87 00 F: +33 3 86 95 19 16
N/A WWW.TEN.COM
D. JAULT
24BLDC21436502 5/5
CE DOCUMENT ET TOUTES LES INFORMATIONS QU'IL CONTIENT SONT LA PROPRIETE CONFIDENTIELLE ET EXCLUSIVE DE T.EN Loading Systems ET NE PEUVENT ETRE REPRODUITS, UTILISES DIVULGUES OU RENDUSPUBLIC SANS L'AUTORISATION EXPRESS DE T.EN Loading Systems.