Lec 070645
Lec 070645
Lec 070645
LTM-1250-6.1
070645
21.03.2014
000001 ZE 0: system error OS-HC11 (observe parameters) initialising error processor-register erroneous E 2
no crane operation possible
if error re-occurs, then ZE should be replaced
000002 ZE 0: system error OS-HC11 (observe parameters) initialising error test total in EPROM/FLASH erroneous E 2
no crane operation possible
check program memory card or ZE
000006 ZE 0: system error OS-HC11 (observe parameters) initialising error RAM erroneous E 2
no crane operation possible
if error re-occurs, then ZE should be replaced
000013 ZE 0: system error OS-HC11 (observe parameters) Test sum in FLASH erroneous E 2
entry in error memory, all crane movements will be stopped
check program memory card
070645 1
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
000017 ZE 0: system error OS-HC11 (observe parameters) total of CPU-time distribution too great E 2
entry in error memory, all crane movements will be stopped
000018 ZE 0: system error OS-HC11 (observe parameters) arithmetic overflow (16 Bit) E 2
entry in error memory, all crane movements will be stopped
000019 ZE 0: system error OS-HC11 (observe parameters) division through zero (16 Bit) E 2
entry in error memory, all crane movements will be stopped
000023 ZE 0: system error OS-HC11 (observe parameters) program incapable of running (type identification) E 2
entry in error memory, all crane movements will be stopped
070645 2
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
000044 ZE 0: system error OS-HC11 (observe parameters) output parameter without effect, from inactive output E 2
entry in error memory, all crane movements will be stopped
000045 ZE 0: system error OS-HC11 (observe parameters) entry parameter undefined, from inactive input E 2
entry in error memory, all crane movements will be stopped
000047 ZE 0: system error OS-HC11 (observe parameters) realtime-control block not available E 2
entry in error memory, all crane movements will be stopped
000049 ZE 0: system error OS-HC11 (observe parameters) urgent modul, ZE not available E 2
entry in error memory, no crane operation possible
check ZE
070645 3
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
000052 ZE 0: system error OS-HC11 (observe parameters) file not open on close E 2
entry in error memory, all crane movements will be stopped
000053 ZE 0: system error OS-HC11 (observe parameters) system mask not available E 2
entry in error memory, all crane movements will be stopped
000054 ZE 0: system error OS-HC11 (observe parameters) system text not available E 2
entry in error memory, all crane movements will be stopped
000057 ZE 0: system error OS-HC11 (observe parameters) default load chart missing E 2
entry in error memory, all crane movements will be stopped
000058 ZE 0: system error OS-HC11 (observe parameters) amplifier erroneous or return power feed E 2
entry in error memory, all crane movements will be stopped
check wiring
070645 4
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
000066 ZE 0: system error OS-HC11 (observe parameters) ADC working outside the permissible tolerance E 2
entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced
000067 ZE 0: system error OS-HC11 (observe parameters) arithmetic processor not available E 2
entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced
000071 ZE 0: system error OS-HC11 (observe parameters) Structure file missing or faulty E 2
entry in error memory, no crane operation possible
070645 5
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
000074 ZE 0: system error OS-HC11 (observe parameters) transformation ASCII to BIN erroneous E 2
entry in error memory, all crane movements will be stopped
000076 ZE 0: system error OS-HC11 (observe parameters) incorrectly inserted power unit E 2
entry in error memory, all crane movements will be stopped
check memory card in power supply unit
070645 6
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
000094 ZE 0: system error OS-HC11 (observe parameters) transmission error parallel bus E 2
entry in error memory, all crane movements will be stopped
check ZE, bus circuit board, power supply unit
002002 ZE 0: system error OS-TMS initialising error test total in EPROM/FLASH erroneous E 2
entry of error in error memory, all crane movements will be stopped
replace ZE
070645 7
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
070645 8
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
070645 9
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
010260 ZE 0: output 2 safety chain error, diode defect or safety contact sticking X70:18 E 1
report of error, otherwise no reaction
checking of safety contact and diode
070645 10
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
070645 11
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
010460 ZE 0: output 4 safety chain error, diode defect or safety contact sticking X70:20 E 1
report of error, otherwise no reaction
checking of safety contact and diode
070645 12
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
010560 ZE 0: output 5 safety chain error, diode defect or safety contact sticking X70:21 E 1
report of error, otherwise no reaction
checking of safety contact and diode
070645 13
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
010660 ZE 0: output 6 safety chain error, diode defect or safety contact sticking X70:22 E 1
report of error, otherwise no reaction
checking of safety contact and diode
070645 14
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
010760 ZE 0: output 7 safety chain error, diode defect or safety contact sticking X70:23 E 1
report of error, otherwise no reaction
checking of safety contact and diode
070645 15
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
020051 ZE 0: LSB participant address 0 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
020053 ZE 0: LSB participant address 0 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
020054 ZE 0: LSB participant address 0 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
070645 16
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
020066 ZE 0: LSB participant address 0 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
020151 ZE 0: LSB participant address 1 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
020153 ZE 0: LSB participant address 1 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
020154 ZE 0: LSB participant address 1 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
070645 17
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
020166 ZE 0: LSB participant address 1 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
020251 ZE 0: LSB participant address 2 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
020253 ZE 0: LSB participant address 2 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
070645 18
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
020254 ZE 0: LSB participant address 2 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
020266 ZE 0: LSB participant address 2 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
020351 ZE 0: LSB participant address 3 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
070645 19
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
020353 ZE 0: LSB participant address 3 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
020354 ZE 0: LSB participant address 3 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
020366 ZE 0: LSB participant address 3 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 20
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
020451 ZE 0: LSB participant address 4 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
020453 ZE 0: LSB participant address 4 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
020454 ZE 0: LSB participant address 4 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
020466 ZE 0: LSB participant address 4 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 21
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
020551 ZE 0: LSB participant address 5 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
020553 ZE 0: LSB participant address 5 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
020554 ZE 0: LSB participant address 5 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
020566 ZE 0: LSB participant address 5 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 22
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
020651 ZE 0: LSB participant address 6 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
020653 ZE 0: LSB participant address 6 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
020654 ZE 0: LSB participant address 6 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
020666 ZE 0: LSB participant address 6 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 23
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
021151 ZE 0: LSB participant address 11 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
021153 ZE 0: LSB participant address 11 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
021154 ZE 0: LSB participant address 11 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
021166 ZE 0: LSB participant address 11 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 24
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
021251 ZE 0: LSB participant address 12 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
021253 ZE 0: LSB participant address 12 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
021254 ZE 0: LSB participant address 12 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
021266 ZE 0: LSB participant address 12 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 25
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
021351 ZE 0: LSB participant address 13 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
021353 ZE 0: LSB participant address 13 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
021354 ZE 0: LSB participant address 13 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
070645 26
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
021366 ZE 0: LSB participant address 13 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
021451 ZE 0: LSB participant address 14 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
021453 ZE 0: LSB participant address 14 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
021454 ZE 0: LSB participant address 14 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
070645 27
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
021466 ZE 0: LSB participant address 14 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
021551 ZE 0: LSB participant address 15 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
021553 ZE 0: LSB participant address 15 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
021554 ZE 0: LSB participant address 15 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
070645 28
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
021566 ZE 0: LSB participant address 15 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
022151 ZE 0: LSB participant address 21 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
022153 ZE 0: LSB participant address 21 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
070645 29
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
022154 ZE 0: LSB participant address 21 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
022166 ZE 0: LSB participant address 21 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
022251 ZE 0: LSB participant address 22 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
070645 30
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
022253 ZE 0: LSB participant address 22 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
022254 ZE 0: LSB participant address 22 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
022266 ZE 0: LSB participant address 22 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 31
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
022351 ZE 0: LSB participant address 23 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
022353 ZE 0: LSB participant address 23 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
022354 ZE 0: LSB participant address 23 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
022366 ZE 0: LSB participant address 23 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 32
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
022451 ZE 0: LSB participant address 24 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
022453 ZE 0: LSB participant address 24 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
022454 ZE 0: LSB participant address 24 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
022466 ZE 0: LSB participant address 24 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 33
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
022551 ZE 0: LSB participant address 25 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
022553 ZE 0: LSB participant address 25 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
022554 ZE 0: LSB participant address 25 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
022566 ZE 0: LSB participant address 25 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 34
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
022851 ZE 0: LSB participant address 28 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
022853 ZE 0: LSB participant address 28 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
022854 ZE 0: LSB participant address 28 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
022866 ZE 0: LSB participant address 28 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 35
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
022951 ZE 0: LSB participant address 29 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
022953 ZE 0: LSB participant address 29 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
022954 ZE 0: LSB participant address 29 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
022966 ZE 0: LSB participant address 29 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 36
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
023252 ZE 0: Control data transfer LSB has recognised Bus collisions, communication interrupted X635:z14/z16 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor
023255 ZE 0: Control data transfer LSB Bus connection faulty/defect, short circuit to supply voltage X635:z14/z16 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
023256 ZE 0: Control data transfer LSB Bus connection faulty/defect, no supply/short circuit to earth X635:z14/z16 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
023257 ZE 0: Control data transfer LSB has recognised network re-set (data transfer starts again) X635:z14/z16 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part
023258 ZE 0: Control data transfer LSB recognised participant with incorrect baud rate in bus X635:z14/z16 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors
023259 ZE 0: Control data transfer LSB recognised communication breakdown in bus X635:z14/z16 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network
023260 ZE 0: Control data transfer LSB driver error: no order to carry out X635:z14/z16 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software
023261 ZE 0: Control data transfer LSB driver error: undefined message appears X635:z14/z16 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination
023262 ZE 0: Control data transfer LSB Driver error: Initialization error X635:z14/z16 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination
070645 37
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
027602 ZE 0: input 28 sensor deficiency data short circuit to supply voltage X635:b26 E 1
report of error, otherwise no reaction
check supply, LICCON input, sensor lines to short or break, sensor
027702 ZE 0: input 29 sensor deficiency data short circuit to supply voltage X635:b28 E 1
report of error, otherwise no reaction
check supply, LICCON input, sensor lines to short or break, sensor
030002 ZE 0: LMB minimum pressure in fly jib retaining cylinder below minimum B 1
error report only
check pressure sensor for fly jib retaining cylinder and replace if necessary
070645 38
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
030041 ZE 0: LMB all data for actual operation mode not available B 3
program stop
install new data memory card with corrected charts
030052 ZE 0: LMB re-fitting with load more than 0.5t and utilization larger 20% B 1
load chart cannot be entered through OK-key
put load to ground or switch crane off and on again
030064 ZE 0: LMB measured overall torque smaller than half torque without charge B 2
LMB-Stop: Load torque increasing movements cannot be affected
move boom out of danger zone or check sensor (angle-, pressure-, length),if load or radius indication incorrect
070645 39
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
030067 ZE 0: LMB STOP, difference between length sensors 1 and 2 too great B 2
LMB-Stop: Load torque increasing movements cannot be affected
set the correct length sensors zero point
030079 ZE 0: LMB STOP, adjusted op. mode and crane configuration not identical B 2
LMB-Stop: Load torque increasing movements cannot be affected
set up crane according to selected operation mode
030122 ZE 0: LMB STOP, end of stroke switch 2 in auxiliary boom op. not connected B 2
LMB-Stop: Load torque increasing movements cannot be affected
connect end of stroke switch 2, or check limit switch or supply line
070645 40
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
030124 ZE 0: LMB STOP, end of stroke switch 3 in auxiliary boom op. not connected B 2
LMB-Stop: Load torque increasing movements cannot be affected
connect end of stroke switch 3, or check limit switch or supply line
030130 ZE 0: LMB STOP, hoist limit switch 4 with 2 winch device not connected E 2
LMB-Stop: Load torque increasing movements cannot be affected
Connect hoist limit switch 4, or check limit switch supply line
030135 ZE 0: LMB permissible deviation of data A/B tension meas. bracket 1 exceeded B 2
LMB-Stop: Load torque increasing movements cannot be affected
check tension connecting brackets or line, stress flow difference in both tension connecting brackets possible
030136 ZE 0: LMB permissible deviation of data A/B tension meas. bracket 2 exceeded B 2
LMB-Stop: Load torque increasing movements cannot be affected
check tension connecting brackets or line, stress flow difference in both tension connecting brackets possible
030137 ZE 0: LMB permissible deviation of data A/B tension meas. bracket 3 exceeded B 2
LMB-Stop: Load torque increasing movements cannot be affected
check tension connecting brackets or line, stress flow difference in both tension connecting brackets possible
030147 ZE 0: LMB working radius list in load chart with incorrect value B 2
LMB-Stop: Load torque increasing movements cannot be affected
install new data memory card with corrected charts
070645 41
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
030153 ZE 0: LMB selected attachment config. not corresponding with actual condition B 2
LMB-Stop: Load torque increasing movements cannot be affected
select load chart corresponding to actual crane configuration
030157 ZE 0: LMB selected slewing range not corresponding with actual condition B 2
LMB-Stop: Load torque increasing movements cannot be affected
enter chart that corresponds to the actual slewing range
030165 ZE 0: LMB difference between upper/lower angle sensor tele too great B 2
LMB-Stop: Load torque increasing movements cannot be affected
retrieve crane deflection through unloading, or check both angle sensors or their lines
070645 42
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
030182 ZE 0: LMB difference between angle sensor cylinder lower/upper too great B 2
LMB-Stop: Load torque increasing movements cannot be affected
retrieve crane deflection through unloading, or check both angle sensors or their lines
030187 ZE 0: LMB actual slewing range different from set slewing range B 2
LMB-Stop: Load torque increasing movements cannot be affected
enter chart according to actual slewing angle of the boom
030190 ZE 0: LMB angle sensor error: load, reach, pulley head height indication defect E 2
LMB-Stop: Load torque increasing movements cannot be affected
check LSB-connection, angle sensor
033941 ZE 0: crane control Emergency operation switched on, Caution shut-downs ineffective B
070645 43
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
034833 ZE 0: control diagnosis system Pressure cut-off swing gear outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check pressure hoist gear, carry out test program again
034856 ZE 0: control diagnosis system slewing gear turning with closed brakes E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
034857 ZE 0: control diagnosis system Initial current swing gear right above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
034858 ZE 0: control diagnosis system Initial current swing gear right below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
034859 ZE 0: control diagnosis system Initial current swing gear left above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
034860 ZE 0: control diagnosis system Initial current swing gear left below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
034861 ZE 0: control diagnosis system slewing speed right slewing gear too low E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
070645 44
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
034862 ZE 0: control diagnosis system slewing speed right slewing gear too high E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
034863 ZE 0: control diagnosis system slewing speed left slewing gear too low E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
034864 ZE 0: control diagnosis system slewing speed left slewing gear too high E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
034865 ZE 0: control diagnosis system Hysteresis right-hand swing gear too great
Carrying out of test program delayed / interrupted
Check proportional-flow valve
034866 ZE 0: control diagnosis system Hysteresis left-hand swing gear too great
Carrying out of test program delayed / interrupted
Check proportional-flow valve
035641 ZE 0: operation telescoping emergency op. telescope activated, caution switch-offs ineffective B
035808 ZE 0: operation slewing shut-down slewing right working area limitation ABB B
operational shut down
slew left until crane is in working area again - shunting through shut-down of working area limitation
035809 ZE 0: operation slewing shut-down slewing left working area limitation ABB B
operational shut down
slew right until crane is in working area again - shunting through shut-down of working area limitation
035810 ZE 0: operation slewing Shut-down free swing gear working area limitation ABB is active B
035811 ZE 0: operation slewing Shut off stop brake slewing gear working range limitation active B
070645 45
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
035812 ZE 0: operation slewing Shut off stop brake slewing gear slewing range limitation limit load B
035824 ZE 0: operation slewing Shut-down free swing gear swing area limitation load is on B
035828 ZE 0: operation slewing Shut off coasting slewing gear sliding arm monitor B
035829 ZE 0: operation slewing Shut off stop brake slewing gear sliding arm monitor B
070645 46
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
035890 ZE 0: operation slewing Slewing platform not bolted or impermissible bolting condition B 1
report of error, otherwise no reaction
Correct bolting position, check position ok: -supply, -input LICCON, -sensor line for short-circuit, -sensor
037313 ZE 0: operation instruments armrest left master switch 2X not in neutral when starting B 1
output of error, shut-down through application
release master switch briefly or check LICCON input, gear lines, sensor
039800 ZE 0: operation diagnosis system interruption, master switch defective or incorrectly deflected B 1
Carrying out of test program delayed / interrupted
Note direction of movements, carry out test program again
039814 ZE 0: operation diagnosis system Alignment aid not correctly shut down B 1
Invalid operation condition, no proper crane operation possible
Apply F key, end active test program
039820 ZE 0: operation diagnosis system interruption, boom angle beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Extend to correct luffing position, carry out test program again
070645 47
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
039821 ZE 0: operation diagnosis system interruption, tele length beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Extend to correct telescopic boom length length, carry out test program again
039822 ZE 0: operation diagnosis system interruption, hook load beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Note max. hook load, carry out test program again
100001 ZE 1: system error OS-HC11 (observe parameters) initialising error processor-register erroneous E 2
no crane operation possible
if error re-occurs, then ZE should be replaced
100002 ZE 1: system error OS-HC11 (observe parameters) initialising error test total in EPROM/FLASH erroneous E 2
no crane operation possible
check program memory card or ZE
100006 ZE 1: system error OS-HC11 (observe parameters) initialising error RAM erroneous E 2
no crane operation possible
if error re-occurs, then ZE should be replaced
070645 48
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
100013 ZE 1: system error OS-HC11 (observe parameters) Test sum in FLASH erroneous E 2
entry in error memory, all crane movements will be stopped
check program memory card
100017 ZE 1: system error OS-HC11 (observe parameters) total of CPU-time distribution too great E 2
entry in error memory, all crane movements will be stopped
100018 ZE 1: system error OS-HC11 (observe parameters) arithmetic overflow (16 Bit) E 2
entry in error memory, all crane movements will be stopped
100019 ZE 1: system error OS-HC11 (observe parameters) division through zero (16 Bit) E 2
entry in error memory, all crane movements will be stopped
070645 49
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
100023 ZE 1: system error OS-HC11 (observe parameters) program incapable of running (type identification) E 2
entry in error memory, all crane movements will be stopped
100044 ZE 1: system error OS-HC11 (observe parameters) output parameter without effect, from inactive output E 2
entry in error memory, all crane movements will be stopped
100045 ZE 1: system error OS-HC11 (observe parameters) entry parameter undefined, from inactive input E 2
entry in error memory, all crane movements will be stopped
100047 ZE 1: system error OS-HC11 (observe parameters) realtime-control block not available E 2
entry in error memory, all crane movements will be stopped
070645 50
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
100049 ZE 1: system error OS-HC11 (observe parameters) urgent modul, ZE not available E 2
entry in error memory, no crane operation possible
check ZE
100052 ZE 1: system error OS-HC11 (observe parameters) file not open on close E 2
entry in error memory, all crane movements will be stopped
100053 ZE 1: system error OS-HC11 (observe parameters) system mask not available E 2
entry in error memory, all crane movements will be stopped
100054 ZE 1: system error OS-HC11 (observe parameters) system text not available E 2
entry in error memory, all crane movements will be stopped
100057 ZE 1: system error OS-HC11 (observe parameters) default load chart missing E 2
entry in error memory, all crane movements will be stopped
070645 51
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
100058 ZE 1: system error OS-HC11 (observe parameters) amplifier erroneous or return power feed E 2
entry in error memory, all crane movements will be stopped
check wiring
100066 ZE 1: system error OS-HC11 (observe parameters) ADC working outside the permissible tolerance E 2
entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced
100067 ZE 1: system error OS-HC11 (observe parameters) arithmetic processor not available E 2
entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced
070645 52
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
100071 ZE 1: system error OS-HC11 (observe parameters) Structure file missing or faulty E 2
entry in error memory, no crane operation possible
100074 ZE 1: system error OS-HC11 (observe parameters) transformation ASCII to BIN erroneous E 2
entry in error memory, all crane movements will be stopped
100076 ZE 1: system error OS-HC11 (observe parameters) incorrectly inserted power unit E 2
entry in error memory, all crane movements will be stopped
check memory card in power supply unit
070645 53
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
100094 ZE 1: system error OS-HC11 (observe parameters) transmission error parallel bus E 2
entry in error memory, all crane movements will be stopped
check ZE, bus circuit board, power supply unit
102002 ZE 1: system error OS-TMS initialising error test total in EPROM/FLASH erroneous E 2
entry of error in error memory, all crane movements will be stopped
replace ZE
070645 54
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
070645 55
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
070645 56
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
110260 ZE 1: output 2 safety chain error, diode defect or safety contact sticking X71:18 E 1
report of error, otherwise no reaction
checking of safety contact and diode
070645 57
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
110360 ZE 1: output 3 safety chain error, diode defect or safety contact sticking X71:19 E 1
report of error, otherwise no reaction
checking of safety contact and diode
070645 58
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
110460 ZE 1: output 4 safety chain error, diode defect or safety contact sticking X71:20 E 1
report of error, otherwise no reaction
checking of safety contact and diode
070645 59
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
110560 ZE 1: output 5 safety chain error, diode defect or safety contact sticking X71:21 E 1
report of error, otherwise no reaction
checking of safety contact and diode
070645 60
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
110660 ZE 1: output 6 safety chain error, diode defect or safety contact sticking X71:22 E 1
report of error, otherwise no reaction
checking of safety contact and diode
070645 61
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
110760 ZE 1: output 7 safety chain error, diode defect or safety contact sticking X71:23 E 1
report of error, otherwise no reaction
checking of safety contact and diode
070645 62
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
070645 63
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
120051 ZE 1: LSB participant address 0 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
120053 ZE 1: LSB participant address 0 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
120054 ZE 1: LSB participant address 0 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
120066 ZE 1: LSB participant address 0 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 64
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
120151 ZE 1: LSB participant address 1 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
120153 ZE 1: LSB participant address 1 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
120154 ZE 1: LSB participant address 1 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
120166 ZE 1: LSB participant address 1 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 65
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
120851 ZE 1: LSB participant address 8 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
120853 ZE 1: LSB participant address 8 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
120854 ZE 1: LSB participant address 8 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
120866 ZE 1: LSB participant address 8 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 66
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
120951 ZE 1: LSB participant address 9 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
120953 ZE 1: LSB participant address 9 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
120954 ZE 1: LSB participant address 9 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
120966 ZE 1: LSB participant address 9 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 67
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
121051 ZE 1: LSB participant address 10 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
121053 ZE 1: LSB participant address 10 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
121054 ZE 1: LSB participant address 10 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
121066 ZE 1: LSB participant address 10 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 68
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
121151 ZE 1: LSB participant address 11 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
121153 ZE 1: LSB participant address 11 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
121154 ZE 1: LSB participant address 11 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
070645 69
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
121166 ZE 1: LSB participant address 11 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
121251 ZE 1: LSB participant address 12 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
121253 ZE 1: LSB participant address 12 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
121254 ZE 1: LSB participant address 12 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
070645 70
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
121266 ZE 1: LSB participant address 12 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
121351 ZE 1: LSB participant address 13 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
121353 ZE 1: LSB participant address 13 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
121354 ZE 1: LSB participant address 13 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
070645 71
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
121366 ZE 1: LSB participant address 13 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
121451 ZE 1: LSB participant address 14 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
121453 ZE 1: LSB participant address 14 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
070645 72
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
121454 ZE 1: LSB participant address 14 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
121466 ZE 1: LSB participant address 14 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
121651 ZE 1: LSB participant address 16 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
070645 73
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
121653 ZE 1: LSB participant address 16 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
121654 ZE 1: LSB participant address 16 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
121666 ZE 1: LSB participant address 16 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 74
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
121751 ZE 1: LSB participant address 17 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
121753 ZE 1: LSB participant address 17 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
121754 ZE 1: LSB participant address 17 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
121766 ZE 1: LSB participant address 17 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 75
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
121851 ZE 1: LSB participant address 18 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
121853 ZE 1: LSB participant address 18 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
121854 ZE 1: LSB participant address 18 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
121866 ZE 1: LSB participant address 18 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 76
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
121951 ZE 1: LSB participant address 19 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
121953 ZE 1: LSB participant address 19 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
121954 ZE 1: LSB participant address 19 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
121966 ZE 1: LSB participant address 19 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 77
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
122051 ZE 1: LSB participant address 20 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
122053 ZE 1: LSB participant address 20 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
122054 ZE 1: LSB participant address 20 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
122066 ZE 1: LSB participant address 20 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 78
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
122151 ZE 1: LSB participant address 21 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
122153 ZE 1: LSB participant address 21 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
122154 ZE 1: LSB participant address 21 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
122166 ZE 1: LSB participant address 21 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 79
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
122251 ZE 1: LSB participant address 22 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
122253 ZE 1: LSB participant address 22 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
122254 ZE 1: LSB participant address 22 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
070645 80
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
122266 ZE 1: LSB participant address 22 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
122351 ZE 1: LSB participant address 23 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
122353 ZE 1: LSB participant address 23 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
122354 ZE 1: LSB participant address 23 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
070645 81
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
122366 ZE 1: LSB participant address 23 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
122551 ZE 1: LSB participant address 25 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
122553 ZE 1: LSB participant address 25 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
122554 ZE 1: LSB participant address 25 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
070645 82
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
122566 ZE 1: LSB participant address 25 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
122651 ZE 1: LSB participant address 26 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
122653 ZE 1: LSB participant address 26 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
070645 83
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
122654 ZE 1: LSB participant address 26 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
122666 ZE 1: LSB participant address 26 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
122951 ZE 1: LSB participant address 29 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
070645 84
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
122953 ZE 1: LSB participant address 29 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
122954 ZE 1: LSB participant address 29 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
122966 ZE 1: LSB participant address 29 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 85
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
123051 ZE 1: LSB participant address 30 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
123053 ZE 1: LSB participant address 30 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
123054 ZE 1: LSB participant address 30 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
123066 ZE 1: LSB participant address 30 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
123252 ZE 1: Control data transfer LSB has recognised Bus collisions, communication interrupted X635A:z14/z16 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor
123255 ZE 1: Control data transfer LSB Bus connection faulty/defect, short circuit to supply voltage X635A:z14/z16 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
123256 ZE 1: Control data transfer LSB Bus connection faulty/defect, no supply/short circuit to earth X635A:z14/z16 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
070645 86
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
123257 ZE 1: Control data transfer LSB has recognised network re-set (data transfer starts again) X635A:z14/z16 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part
123258 ZE 1: Control data transfer LSB recognised participant with incorrect baud rate in bus X635A:z14/z16 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors
123259 ZE 1: Control data transfer LSB recognised communication breakdown in bus X635A:z14/z16 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network
123260 ZE 1: Control data transfer LSB driver error: no order to carry out X635A:z14/z16 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software
123261 ZE 1: Control data transfer LSB driver error: undefined message appears X635A:z14/z16 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination
123262 ZE 1: Control data transfer LSB Driver error: Initialization error X635A:z14/z16 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination
130570 ZE 1: remote control emergency operation telescoping movement selected with LICCON B 1
070645 87
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
130611 ZE 1: Data recorder Start: Crane number faulty (not 9 figures numerically) E 1
Data recorder software stops - no documentation possible!
Define crane number correctly (Sxxxxxxx.yyQ - KNFttt00vvrr.Q)
070645 88
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
132650 ZE 1: control telescoping Tele recognition faulty, more than one track switch reporting active B
Telescoping blocked, telestatus possibly tipped, possibly incorrect/no telescopic boom length length
Switched limit switch, check cylinder attachment
132680 ZE 1: control telescoping "Folding jib pivoted in" mounted, folding jib not mounted E
132681 ZE 1: control telescoping "Special auxiliary boom swung in" mounted, accessory not mounted E
070645 89
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
135608 ZE 1: operation telescoping shut-down tele OUT main boom working area limitation ABB B
135609 ZE 1: operation telescoping shut-down tele IN main boom working area limitation ABB B
135613 ZE 1: operation telescoping shut-down as flap not positioned and angle threshold exceeded B
135614 ZE 1: operation telescoping pressure retaining cylinder RFP N shut-down outside set range B
135616 ZE 1: operation telescoping shut-down extending accessory working area limitation ABB B
135617 ZE 1: operation telescoping shut-down retracting accessory working area limitation ABB B
070645 90
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
135629 ZE 1: operation telescoping Shut off hose drum accessories not clear B
operational shut down
070645 91
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
135660 ZE 1: operation telescoping unbolting telescope not possible, cylinder is not bolted B
135663 ZE 1: operation telescoping unbolting cylinder not possible, telescope is not bolted B
070645 92
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
135664 ZE 1: operation telescoping unbolting cylinder not possible, automatic system adjusted B
135665 ZE 1: operation telescoping unbolting telescope not possible, automatic system adjusted B
135670 ZE 1: operation telescoping shut-down both limit switches "flap in position" defect./missing B
135671 ZE 1: operation telescoping shut-down both limit switches "NA-boom 3 pos." defect./missing B
135672 ZE 1: operation telescoping shut-down both angle sensors "fly jib" defective/missing B
135673 ZE 1: operation telescoping shut-down both limit switches "lower fly jib" defective/missing B
135674 ZE 1: operation telescoping shut-down both limit switches "upper fly jib flap" defect./missing B
135675 ZE 1: operation telescoping shut-down both limit switches "upper fly jib stop"defect./missing B
070645 93
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
135684 ZE 1: operation telescoping shut-down both limit switches "transp. setting N" defect./missing B
135690 ZE 1: operation telescoping cylinder bolting is neither unpinned nor in a pivot section B
135708 ZE 1: operation luffing luffing up of main boom shut-down working area limitation ABB B 1
operational shut down
luff main boom down until crane is in working area again - shunting through shut-down of working area limitation
135709 ZE 1: operation luffing luffing down of main boom shut-down working area limitation ABB B 1
operational shut down
luff main boom up until crane in working area again - shunting through shut-down of working area limitation
070645 94
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
135712 ZE 1: operation luffing shut-down as lower fly jib and NA-boom 3 not positioned B
135713 ZE 1: operation luffing shut-down as flap not positioned and angle threshold exceeded B
135714 ZE 1: operation luffing pressure retaining cylinder RFP N shut-down outside set range B
070645 95
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
135741 ZE 1: operation luffing Luffing down shut-down, pressure supply auxiliary consumer selected B
135747 ZE 1: operation luffing Warning luffing up, dropping of load with reduction of reach B
135748 ZE 1: operation luffing Shut-down luffing up, dropping of load with reduction of reach B
070645 96
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
135770 ZE 1: operation luffing shut-down both limit switches "flap in position" defect./missing B
135772 ZE 1: operation luffing shut-down both angle sensors "fly jib" defective/missing B
135773 ZE 1: operation luffing shut-down both limit switches "lower fly jib" defective/missing B
135774 ZE 1: operation luffing shut-down both limit switches "upper fly jib flap" defect./missing B
135775 ZE 1: operation luffing shut-down both limit switches "upper fly jib stop"defect./missing B
070645 97
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
135784 ZE 1: operation luffing shut-down both limit switches "transp. setting N" defect./missing B
136006 ZE 1: operation additional equipment Shut off Luffing up fixed jib upper limit angle OGW B 1
operational shut down
luff main boom down until radius is within load chart again - shut-down can be shunted (danger)
136007 ZE 1: operation additional equipment Shut off Luffing down fixed jib lower limit angle UGW B 1
operational shut down
luff main boom up until radius is within load chart again- shut-down can be shunted (danger)
136008 ZE 1: operation additional equipment Shut off Luffing up fixed jib working range limitation ABB B 1
operational shut down
luff main boom down until crane is in working area again - shunting through shut-down of working area limitation
136009 ZE 1: operation additional equipment Shut off Luffing down fixed jib working range limitation ABB B 1
operational shut down
luff main boom up until crane in working area again - shunting through shut-down of working area limitation
070645 98
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
136041 ZE 1: operation additional equipment Emerg. op. crane control switched on Caution shut-down ineffective B
136047 ZE 1: operation additional equipment Warning luffing up, dropping of load with reduction of reach B
136048 ZE 1: operation additional equipment Shut-down luffing up, dropping of load with reduction of reach B
136049 ZE 1: operation additional equipment Shut off Luffing down fixed jib hoist limit switch 4 B 1
operational shut down
luff main boom up until end of stroke switch is no longer activated - shut-down can be shunted(danger)
136050 ZE 1: operation additional equipment Shut off Luffing down fixed jib hoist limit switch 1 B 1
operational shut down
luff main boom up until end of stroke switch is no longer activated - shut-down can be shunted(danger)
136051 ZE 1: operation additional equipment Shut off Luffing down fixed jib hoist limit switch 2 B 1
operational shut down
luff main boom up until end of stroke switch is no longer activated - shut-down can be shunted(danger)
136052 ZE 1: operation additional equipment Shut off Luffing down fixed jib hoist limit switch 3 B 1
operational shut down
luff main boom up until end of stroke switch is no longer activated - shut-down can be shunted(danger)
136081 ZE 1: operation additional equipment Shut off Luff down fixed jib hoist limit switch 1 erroneous/missing B
136082 ZE 1: operation additional equipment Shut off Luff down fixed jib hoist limit switch 2 erroneous/missing B
070645 99
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
136083 ZE 1: operation additional equipment Shut off Luff down fixed jib hoist limit switch 3 erroneous/missing B
136089 ZE 1: operation additional equipment Shut off Luff down fixed jib hoist limit switch 4 erroneous/missing B
137201 ZE 1: operation instruments armrest right master switch 1X not in neutral when starting B 1
output of error, shut-down through application
release master switch briefly or check LICCON input, gear lines, sensor
137312 ZE 1: operation instruments armrest left master switch 2Y not in neutral when starting B 1
output of error, shut-down through application
release master switch briefly or check LICCON input, gear lines, sensor
139800 ZE 1: operation diagnosis system interruption, master switch defective or incorrectly deflected B 1
Carrying out of test program delayed / interrupted
Note direction of movements, carry out test program again
139814 ZE 1: operation diagnosis system Alignment aid not correctly shut down B 1
Invalid operation condition, no proper crane operation possible
Apply F key, end active test program
139820 ZE 1: operation diagnosis system interruption, boom angle beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Extend to correct luffing position, carry out test program again
139821 ZE 1: operation diagnosis system interruption, tele length beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Extend to correct telescopic boom length length, carry out test program again
070645 100
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
139822 ZE 1: operation diagnosis system interruption, hook load beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Note max. hook load, carry out test program again
161002 E/A-Modul 1: system error OS-C167 initialising error test total in EPROM/FLASH erroneous E 2
error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul
070645 101
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
161088 E/A-Modul 1: system error OS-C167 Configuration does not match software condition E 1
Error output, possible error functions of module
Carry out EAM-download from LICCON
172052 E/A-Modul 1: input/output DEA0 output open, to low load, short circuit to supply voltage X613:17 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
172053 E/A-Modul 1: input/output DEA0 transistor current supply insufficient or missing X613:17 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
172055 E/A-Modul 1: input/output DEA0 excessive temperature, short circuit to ground or overload X613:17 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
172152 E/A-Modul 1: input/output DEA1 output open, to low load, short circuit to supply voltage X613:15 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
070645 102
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
172153 E/A-Modul 1: input/output DEA1 transistor current supply insufficient or missing X613:15 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
172155 E/A-Modul 1: input/output DEA1 excessive temperature, short circuit to ground or overload X613:15 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
172252 E/A-Modul 1: input/output DEA2 output open, to low load, short circuit to supply voltage X613:13 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
172253 E/A-Modul 1: input/output DEA2 transistor current supply insufficient or missing X613:13 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
172255 E/A-Modul 1: input/output DEA2 excessive temperature, short circuit to ground or overload X613:13 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
172352 E/A-Modul 1: input/output DEA3 output open, to low load, short circuit to supply voltage X613:11 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
172353 E/A-Modul 1: input/output DEA3 transistor current supply insufficient or missing X613:11 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
070645 103
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
172355 E/A-Modul 1: input/output DEA3 excessive temperature, short circuit to ground or overload X613:11 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
172452 E/A-Modul 1: input/output DEA4 output open, to low load, short circuit to supply voltage X613:9 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
172453 E/A-Modul 1: input/output DEA4 transistor current supply insufficient or missing X613:9 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
172455 E/A-Modul 1: input/output DEA4 excessive temperature, short circuit to ground or overload X613:9 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
172552 E/A-Modul 1: input/output DEA5 output open, to low load, short circuit to supply voltage X613:7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
172553 E/A-Modul 1: input/output DEA5 transistor current supply insufficient or missing X613:7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
172555 E/A-Modul 1: input/output DEA5 excessive temperature, short circuit to ground or overload X613:7 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
172652 E/A-Modul 1: input/output DEA6 output open, to low load, short circuit to supply voltage X613:5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
070645 104
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
172653 E/A-Modul 1: input/output DEA6 transistor current supply insufficient or missing X613:5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
172655 E/A-Modul 1: input/output DEA6 excessive temperature, short circuit to ground or overload X613:5 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
172752 E/A-Modul 1: input/output DEA7 output open, to low load, short circuit to supply voltage X613:3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
172753 E/A-Modul 1: input/output DEA7 transistor current supply insufficient or missing X613:3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
172755 E/A-Modul 1: input/output DEA7 excessive temperature, short circuit to ground or overload X613:3 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
173481 E/A-Modul 1: voltage input E4 short circuit to supply voltage, open line X612:9 E 1
symbol for brake pressure 1 is flashing on the display unit
check input signal on the E/A-Modul or sensor
173581 E/A-Modul 1: voltage input E5 short circuit to supply voltage, open line X612:7 E 1
symbol for brake pressure 2 is flashing on the display unit
check input signal on the E/A-Modul or sensor
173782 E/A-Modul 1: voltage input E7 short circuit to ground, open line, constant current 10 mA incorrect X612:3 E 1
no reaction
check input signal on the E/A-Modul or sensor
070645 105
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
173783 E/A-Modul 1: voltage input E7 short circuit to supply voltage, open line, lack of voltage X612:3 E 1
no reaction
check input signal on the E/A-Modul or sensor
179052 E/A-Modul 1: output A0 output open, to low load, short circuit to supply voltage X613:18 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
179055 E/A-Modul 1: output A0 excessive temperature, short circuit to ground or overload X613:18 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
179152 E/A-Modul 1: output A1 output open, to low load, short circuit to supply voltage X613:16 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
179155 E/A-Modul 1: output A1 excessive temperature, short circuit to ground or overload X613:16 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
179250 E/A-Modul 1: bridge output A2 short circuit to ground, junction not supplied X613:14 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul
070645 106
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
179251 E/A-Modul 1: bridge output A2 short circuit to supply voltage, excessive temperature X613:14 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul
179252 E/A-Modul 1: bridge output A2 output open, to low load, short circuit to supply voltage X613:14 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
179253 E/A-Modul 1: bridge output A2 transistor current supply insufficient or missing X613:14 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
179255 E/A-Modul 1: bridge output A2 excessive temperature, short circuit to ground or overload X613:14 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
179350 E/A-Modul 1: bridge output A3 short circuit to ground, junction not supplied X613:12 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul
179351 E/A-Modul 1: bridge output A3 short circuit to supply voltage, excessive temperature X613:12 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul
179352 E/A-Modul 1: bridge output A3 output open, to low load, short circuit to supply voltage X613:12 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
179353 E/A-Modul 1: bridge output A3 transistor current supply insufficient or missing X613:12 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
070645 107
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
179355 E/A-Modul 1: bridge output A3 excessive temperature, short circuit to ground or overload X613:12 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
183401 E/A-Modul 1: SPI-control unit Faulty data transfer E/A-module<>unit (time exceeded) X614:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul
183402 E/A-Modul 1: SPI-control unit Serious system error to SPI-connection (interface) X614:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul
183403 E/A-Modul 1: SPI-control unit break in line or short circuit to supply voltage X614:1/2/3/5/6/ E 1
error indication on display 7/8
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary
183404 E/A-Modul 1: SPI-control unit break in line or short circuit to ground X614:1/2/3/5/6/ E 1
error indication on display 7/8
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary
183406 E/A-Modul 1: SPI-control unit Data transfer faulty (faulty check byte) X614:1/2/3/5/6/ E 1
error indication on display 7/8
suppress EMV- interference
183407 E/A-Modul 1: SPI-control unit Unit faulty/missing, incorrect unit inserted (ID) X614:1/2/3/5/6/ E 1
error indication on display 7/8
check periphery and replace if necessary, check Software version, check EMV- interference
183408 E/A-Modul 1: SPI-control unit Data transfer faulty (incorrect number of data bytes received) X614:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul
183900 E/A-Modul 1: Control operating unit (SPI) Faulty initialisation data connection E/A-module<>unit X614:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul
183902 E/A-Modul 1: Control operating unit (SPI) Serious system error to SPI-connection (interface) X614:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul
070645 108
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
183905 E/A-Modul 1: Control operating unit (SPI) Initialisation error, resetting inputs/outputs faulty X614:1/2/3/5/6/ E 1
error indication on display 7/8
check wiring, check periphery and replace if necessary, check E/A-Modul and replace if necessary
183907 E/A-Modul 1: Control operating unit (SPI) Unit faulty/missing, incorrect unit inserted (ID) X614:1/2/3/5/6/ E 1
error indication on display 7/8
connect functional periphery unit, system then eliminates error independently
183908 E/A-Modul 1: Control operating unit (SPI) Data transfer faulty (incorrect number of data bytes received) X614:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul
184150 E/A-Modul 1: LSB-B participant address 1 reports an incorrect sensor type X613:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
184151 E/A-Modul 1: LSB-B participant address 1 was not configured for the block transfer X613:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
184153 E/A-Modul 1: LSB-B participant address 1 no longer reports or withdrawn during running period X613:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
184154 E/A-Modul 1: LSB-B participant address 1 Features other settings (parameters) as pre-entered set values X613:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
070645 109
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
184164 E/A-Modul 1: LSB-B participant address 1 reports tolerable error in self-test X613:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
184165 E/A-Modul 1: LSB-B participant address 1 reports intolerable error in self-test X613:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
184166 E/A-Modul 1: LSB-B participant address 1 with software version, that is no longer compatible X613:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
184250 E/A-Modul 1: LSB-B participant address 2 reports an incorrect sensor type X613:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
184251 E/A-Modul 1: LSB-B participant address 2 was not configured for the block transfer X613:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
184253 E/A-Modul 1: LSB-B participant address 2 no longer reports or withdrawn during running period X613:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
070645 110
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
184254 E/A-Modul 1: LSB-B participant address 2 Features other settings (parameters) as pre-entered set values X613:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
184264 E/A-Modul 1: LSB-B participant address 2 reports tolerable error in self-test X613:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
184265 E/A-Modul 1: LSB-B participant address 2 reports intolerable error in self-test X613:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
184266 E/A-Modul 1: LSB-B participant address 2 with software version, that is no longer compatible X613:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
184350 E/A-Modul 1: LSB-B participant address 3 reports an incorrect sensor type X613:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
184351 E/A-Modul 1: LSB-B participant address 3 was not configured for the block transfer X613:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
070645 111
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
184353 E/A-Modul 1: LSB-B participant address 3 no longer reports or withdrawn during running period X613:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
184354 E/A-Modul 1: LSB-B participant address 3 Features other settings (parameters) as pre-entered set values X613:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
184364 E/A-Modul 1: LSB-B participant address 3 reports tolerable error in self-test X613:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
184365 E/A-Modul 1: LSB-B participant address 3 reports intolerable error in self-test X613:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
184366 E/A-Modul 1: LSB-B participant address 3 with software version, that is no longer compatible X613:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
184450 E/A-Modul 1: LSB-B participant address 4 reports an incorrect sensor type X613:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
070645 112
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
184451 E/A-Modul 1: LSB-B participant address 4 was not configured for the block transfer X613:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
184453 E/A-Modul 1: LSB-B participant address 4 no longer reports or withdrawn during running period X613:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
184454 E/A-Modul 1: LSB-B participant address 4 Features other settings (parameters) as pre-entered set values X613:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
184464 E/A-Modul 1: LSB-B participant address 4 reports tolerable error in self-test X613:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
184465 E/A-Modul 1: LSB-B participant address 4 reports intolerable error in self-test X613:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
184466 E/A-Modul 1: LSB-B participant address 4 with software version, that is no longer compatible X613:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 113
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
184550 E/A-Modul 1: LSB-B participant address 5 reports an incorrect sensor type X613:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
184551 E/A-Modul 1: LSB-B participant address 5 was not configured for the block transfer X613:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
184553 E/A-Modul 1: LSB-B participant address 5 no longer reports or withdrawn during running period X613:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
184554 E/A-Modul 1: LSB-B participant address 5 Features other settings (parameters) as pre-entered set values X613:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
184564 E/A-Modul 1: LSB-B participant address 5 reports tolerable error in self-test X613:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
184565 E/A-Modul 1: LSB-B participant address 5 reports intolerable error in self-test X613:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
184566 E/A-Modul 1: LSB-B participant address 5 with software version, that is no longer compatible X613:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 114
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
184650 E/A-Modul 1: LSB-B participant address 6 reports an incorrect sensor type X613:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
184651 E/A-Modul 1: LSB-B participant address 6 was not configured for the block transfer X613:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
184653 E/A-Modul 1: LSB-B participant address 6 no longer reports or withdrawn during running period X613:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
184654 E/A-Modul 1: LSB-B participant address 6 Features other settings (parameters) as pre-entered set values X613:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
184664 E/A-Modul 1: LSB-B participant address 6 reports tolerable error in self-test X613:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
184665 E/A-Modul 1: LSB-B participant address 6 reports intolerable error in self-test X613:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
184666 E/A-Modul 1: LSB-B participant address 6 with software version, that is no longer compatible X613:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
187252 E/A-Modul 1: Control data transfer LSB-B has recognised Bus collisions, communication interrupted X613:4/6 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor
070645 115
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
187255 E/A-Modul 1: Control data transfer LSB-B Bus connection faulty/defect, short circuit to supply voltage X613:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
187256 E/A-Modul 1: Control data transfer LSB-B Bus connection faulty/defect, no supply/short circuit to earth X613:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
187257 E/A-Modul 1: Control data transfer LSB-B has recognised network re-set (data transfer starts again) X613:4/6 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part
187258 E/A-Modul 1: Control data transfer LSB-B recognised participant with incorrect baud rate in bus X613:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors
187259 E/A-Modul 1: Control data transfer LSB-B recognised communication breakdown in bus X613:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network
187260 E/A-Modul 1: Control data transfer LSB-B driver error: no order to carry out X613:4/6 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software
187261 E/A-Modul 1: Control data transfer LSB-B driver error: undefined message appears X613:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination
187262 E/A-Modul 1: Control data transfer LSB-B Driver error: Initialization error X613:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination
187530 E/A-Modul 1: CAN-participant engine Data transfer subscriber transfer cycle exceeded X615:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul
187531 E/A-Modul 1: CAN-participant engine Data transfer faulty/missing, max. cycle time exceeded X615:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
070645 116
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
187630 E/A-Modul 1: CAN-participant gear Data transfer subscriber transfer cycle exceeded X615:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul
187631 E/A-Modul 1: CAN-participant gear Data transfer faulty/missing, max. cycle time exceeded X615:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
187730 E/A-Modul 1: CAN-participant ABV (ABS/ASR) Data transfer subscriber transfer cycle exceeded X615:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul
187731 E/A-Modul 1: CAN-participant ABV (ABS/ASR) Data transfer faulty/missing, max. cycle time exceeded X615:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
187930 E/A-Modul 1: CAN-participant retarder Data transfer subscriber transfer cycle exceeded X615:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul
187931 E/A-Modul 1: CAN-participant retarder Data transfer faulty/missing, max. cycle time exceeded X615:5/6 E 1
parameterised substitute values for receiver signals will be used
Check CAN network, check faulty Bus user.
188030 E/A-Modul 1: CAN-user converter clutch unit CCU Data transfer subscriber transfer cycle exceeded X615:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul
188031 E/A-Modul 1: CAN-user converter clutch unit CCU Data transfer faulty/missing, max. cycle time exceeded X615:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
188530 E/A-Modul 1: CAN-participant E/A-Modul 1 Data transfer subscriber transfer cycle exceeded X615:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant
188531 E/A-Modul 1: CAN-participant E/A-Modul 1 Data transfer faulty/missing, max. cycle time exceeded X615:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
070645 117
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
188930 E/A-Modul 1: CAN-participant E/A-Modul 5 Data transfer subscriber transfer cycle exceeded X615:5/6 E 1
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant
188931 E/A-Modul 1: CAN-participant E/A-Modul 5 Data transfer faulty/missing, max. cycle time exceeded X615:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
189900 E/A-Modul 1: Control data transfer CAN internal error at Register-check Controller X615:5/6 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul
189901 E/A-Modul 1: Control data transfer CAN internal error at RAM-check Controller X615:5/6 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul
189902 E/A-Modul 1: Control data transfer CAN Configuration error Software X615:5/6 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul, check Software (test system ZE)
189903 E/A-Modul 1: Control data transfer CAN Transfer interrupted after continuous error X615:5/6 E 1
CAN-Transmission will be aborted
check bus lines/neutral point, replace neutral point or E/A-Modul
189910 E/A-Modul 1: Control data transfer CAN short-term error in bus connection X615:5/6 E 0
re-attachment of Modul to bus transmission
check bus lines/neutral point, unplug individual bus participant and check if error has been eliminated
189911 E/A-Modul 1: Control data transfer CAN permanent error bus connection X615:5/6 E 1
cyclic re-attachment of Modul to bus transmission
check bus lines/neutral point, unplug individual bus participant and check if error has been eliminated
189920 E/A-Modul 1: Control data transfer CAN active participant not responding X615:5/6 E 0
parameterised substitute values for receiver signals will be used
check error report for missing participant(s), test system ZE
189921 E/A-Modul 1: Control data transfer CAN No active subscriber responding X615:5/6 E 1
parameterised substitute values for receiver signals will be used
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul
070645 118
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
189950 E/A-Modul 1: Control data transfer CAN erroneous command test system X615:5/6 E 1
no reaction to unknown test system control command in CAN-System Software
check Software (test system)
192001 E/A-Modul 1: control engine long-term disruption E/A-Modul <-> engine control E 1
engine control and E/A-Modul at emergency speed
engine control and E/A-Modul, check CAN-bus-connections
192110 E/A-Modul 1: control transmission long-term disruption shift selector operation unit <-> gears E 1
transmission control and E/A-Modul (operation unit) in emergency drive program
check transmission control and E/A-Modul, CAN-bus-connection
192112 E/A-Modul 1: control transmission long-term disruption connection E/A-Modul <-> operation unit E 1
transmission control and E/A-Modul (operation unit) in emergency drive program
check connection E/A-Modul<>operation unit, power supplies operation unit; replace E/A- Modul or operation unit
192113 E/A-Modul 1: control transmission error in shift selector keys operation unit: key sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit
192114 E/A-Modul 1: control transmission shift selector operation unit: D key sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit
192115 E/A-Modul 1: control transmission shift selector operation unit: N key sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit
192116 E/A-Modul 1: control transmission shift selector operation unit: R key sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit
192117 E/A-Modul 1: control transmission shift selector operation unit: gear+ key sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit
192118 E/A-Modul 1: control transmission shift selector operation unit: gear- key sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit
070645 119
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
192119 E/A-Modul 1: control transmission shift selector operation unit: travel program key 1/2 sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit
192128 E/A-Modul 1: control transmission feedback of off-road gear simultaneously ON and OFF E 1
control system prevents disengagement of the off-road gear ON or OFF, remaining in actual position when ignition ON
check sensor for acknowledgement(s), check line connections to the E/A-Modul, replace E/A-Modul
194800 E/A-Modul 1: control diagnosis system error in diagnosis requirement CAN-participant engine E 0
ISO-Diagnosis-inquiry will be interrupted and if necessary carried out again
check CAN-network, check CAN-paticipants
070645 120
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
194801 E/A-Modul 1: control diagnosis system error in diagnosis requirement CAN-participant gears E 0
ISO-Diagnosis-inquiry will be interrupted and if necessary carried out again
check CAN-network, check CAN-paticipants
194802 E/A-Modul 1: control diagnosis system error in diagnosis requirement CAN-participant ABS E 0
ISO-Diagnosis-inquiry will be interrupted and if necessary carried out again
check CAN-network, check CAN-paticipants
194810 E/A-Modul 1: control diagnosis system error in test system-diagnosis CAN-participant engine E 0
ISO-Diagnosis-inquiry will be interrupted and if necessary carried out again
check CAN-network, check CAN-paticipants
194811 E/A-Modul 1: control diagnosis system error in test system-diagnosis CAN-participant gears E 0
ISO-Diagnosis-inquiry will be interrupted and if necessary carried out again
check CAN-network, check CAN-paticipants
194812 E/A-Modul 1: control diagnosis system error in test system-diagnosis CAN-participant ABS E 0
ISO-Diagnosis-inquiry will be interrupted and if necessary carried out again
check CAN-network, check CAN-paticipants
195151 E/A-Modul 1: operation transmission CAN-connection shift selector <-> gear electronics malfunctioning B
function is not carried out
195152 E/A-Modul 1: operation transmission connection shift selector <-> keyboard unit malfunctioning B
function is not carried out
195153 E/A-Modul 1: operation transmission pre-selection not neutral/crane op. cab malfunction <-> E/A-Modul B
function is not carried out
195154 E/A-Modul 1: operation transmission shift selector out of order: upper-carriage-operation mode B
function is not carried out
070645 121
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
195161 E/A-Modul 1: operation transmission shift selector out of order: key sticking B
function is not carried out
195172 E/A-Modul 1: operation transmission selection of travel direction prevented, op. type not recognized B
function is not carried out
195173 E/A-Modul 1: operation transmission selection of travel dir. prevented, multi-shift selector keys activ. B
function is not carried out
195174 E/A-Modul 1: operation transmission shift selector out of order when engine OFF B
function is not carried out
195175 E/A-Modul 1: operation transmission selection of travel dir. prevented, pre-selection in neutral only B
function is not carried out
195176 E/A-Modul 1: operation transmission selection of travel direction prevented, operation brake not active B
function is not carried out
195179 E/A-Modul 1: operation transmission pre-selection gear+ prevented, maximum gear attained B
function is not carried out
195180 E/A-Modul 1: operation transmission pre-selection gear+ prevented, rear axle not locked B
function is not carried out
195183 E/A-Modul 1: operation transmission pre-selection gear- prevented, minimum gear attained B
function is not carried out
070645 122
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
195190 E/A-Modul 1: operation transmission travel program change-over only possible in neutral B
function is not carried out
195501 E/A-Modul 1: operation axle suspension operation of 2-hand-function without activation of 2-hand-key B
function is not carried out
activate both keys simultaneously or start test program of keyboard unit
195503 E/A-Modul 1: operation axle suspension operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)
195505 E/A-Modul 1: operation axle suspension operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode
195570 E/A-Modul 1: operation axle suspension undefined condition: neither blocked nor with suspension B
function is not carried out
check blocked limit switch and buffered limit switch
195571 E/A-Modul 1: operation axle suspension undefined condition: blocked and with suspension B
function is not carried out
check blocked limit switch and buffered limit switch
195572 E/A-Modul 1: operation axle suspension function only possible on condition "axles with suspension" B
function is not carried out
switch axle suspension to suspended and lower axle, then block axles 5+6 and level axle suspension
195573 E/A-Modul 1: operation axle suspension function only possible on condition "axles blocked" B
function is not carried out
switch on axle blocking
070645 123
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
195574 E/A-Modul 1: operation axle suspension unauthorised switch-over in condition "axles with suspension" B
function is not carried out
lift blockage of function
195575 E/A-Modul 1: operation axle suspension unauthorised switch-over in condition "axles blocked" B
function is not carried out
lift blockage of function
195603 E/A-Modul 1: operation level/filling/draining operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)
195605 E/A-Modul 1: operation level/filling/draining operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode
195642 E/A-Modul 1: operation level/filling/draining no individual operation when level function is active B
function is not carried out
only activate level key
070645 124
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
195701 E/A-Modul 1: operation axle compensation operation of 2-hand-function without activation of 2-hand-key B
function is not carried out
195707 E/A-Modul 1: operation axle compensation operation from under-carriage without initialisation B
function is not carried out
195747 E/A-Modul 1: operation axle compensation axle long. compensation switchable only if axle suspens. blocked B
function is not carried out
195901 E/A-Modul 1: operation longitudinal lock operation of 2-hand-function without activation of 2-hand-key B
function is not carried out
activate both keys simultaneously or start test program of keyboard unit
195902 E/A-Modul 1: operation longitudinal lock operation from upper-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)
195903 E/A-Modul 1: operation longitudinal lock operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)
195904 E/A-Modul 1: operation longitudinal lock operation from upper-carriage with under-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to uppercarriage operation mode
195905 E/A-Modul 1: operation longitudinal lock operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode
195906 E/A-Modul 1: operation longitudinal lock operation from upper-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection to E/A-Modul 4
070645 125
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
195907 E/A-Modul 1: operation longitudinal lock operation from under-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection to E/A-Modul 4
195953 E/A-Modul 1: operation longitudinal lock switch-over prevented as axles are raised B
function is not carried out
switch on off-road gear
196001 E/A-Modul 1: operation transversal lock operation of 2-hand-function without activation of 2-hand-key B
function is not carried out
activate both keys simultaneously or start test program of keyboard unit
196003 E/A-Modul 1: operation transversal lock operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) on E/A-Modul 4, check LSB-connection (see electric circuit diagram)
196005 E/A-Modul 1: operation transversal lock operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode
196007 E/A-Modul 1: operation transversal lock operation from under-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection to E/A-Modul 4
070645 126
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
196052 E/A-Modul 1: operation transversal lock selection of transversal lock ON with no longitudinal lock selected B
function is not carried out
acivate longitudinal locking
196100 E/A-Modul 1: operation unlocking rear axle function simultaneously ON and OFF B
function is not carried out
do not simultaneously activate contrasting function keys
196101 E/A-Modul 1: operation unlocking rear axle operation of 2-hand-function without activation of 2-hand-key B
function is not carried out
activate both keys simultaneously or start test program of keyboard unit
196102 E/A-Modul 1: operation unlocking rear axle operation from upper-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)
196103 E/A-Modul 1: operation unlocking rear axle operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)
196104 E/A-Modul 1: operation unlocking rear axle operation from upper-carriage with under-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to uppercarriage operation mode
196105 E/A-Modul 1: operation unlocking rear axle operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode
196106 E/A-Modul 1: operation unlocking rear axle operation from upper-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection to E/A-Modul 4
196107 E/A-Modul 1: operation unlocking rear axle operation from under-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection to E/A-Modul 4
070645 127
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
196108 E/A-Modul 1: operation unlocking rear axle unauthorised operation from upper-carriage B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)
196109 E/A-Modul 1: operation unlocking rear axle unauthorised operation from under-carriage B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)
196112 E/A-Modul 1: operation unlocking rear axle unauthorised switching off of function B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)
196114 E/A-Modul 1: operation unlocking rear axle activation of function without operation mode B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)
196115 E/A-Modul 1: operation unlocking rear axle gear limit forwards exceeded with under-carriage operation mode B
function is not carried out
engage lower gear
196116 E/A-Modul 1: operation unlocking rear axle gear limit backwards exceeded with under-carriage operation mode B
function is not carried out
engage lower gear
196117 E/A-Modul 1: operation unlocking rear axle gear limit forwards exceeded with upper-carriage operation mode B
function is not carried out
engage lower gear
196118 E/A-Modul 1: operation unlocking rear axle gear limit backwards exceeded with upper-carriage operation mode B
function is not carried out
engage lower gear
070645 128
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
196119 E/A-Modul 1: operation unlocking rear axle no direction with under-carriage operation mode B
function is not carried out
check CAN-connection and LSB-connection
196120 E/A-Modul 1: operation unlocking rear axle no direction with upper-carriage operation mode B
function is not carried out
check CAN-connection and LSB-connection
196160 E/A-Modul 1: operation unlocking rear axle undefined condition: simultaneously locked and unlocked B
function is not carried out
check unlocking condition, Check locking limit switch and unlocking limit switch
196200 E/A-Modul 1: operation steering rear axle function simultaneously ON and OFF B
function is not carried out
do not simultaneously activate contrasting function keys
196202 E/A-Modul 1: operation steering rear axle operation from upper-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)
196203 E/A-Modul 1: operation steering rear axle operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)
196204 E/A-Modul 1: operation steering rear axle operation from upper-carriage with under-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to uppercarriage operation mode
196205 E/A-Modul 1: operation steering rear axle operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode
196208 E/A-Modul 1: operation steering rear axle unauthorised operation from upper-carriage B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)
196209 E/A-Modul 1: operation steering rear axle unauthorised operation from under-carriage B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)
070645 129
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
196263 E/A-Modul 1: operation steering rear axle no valid lock condition in upper-carriage operation mode B
function is not carried out
check unlocking condition, Check locking limit switch and unlocking limit switch
196264 E/A-Modul 1: operation steering rear axle no valid lock condition in under-carriage operation mode B
function is not carried out
check unlocking condition, Check locking limit switch and unlocking limit switch
196265 E/A-Modul 1: operation steering rear axle unauthorised steering selection in upper-carriage B
function is not carried out
steering only with rear axle unlocked, check LSB-connection
196266 E/A-Modul 1: operation steering rear axle unauthorised steering selection in under-carriage B
function is not carried out
steering only with rear axle unlocked, check LSB-connection
196570 E/A-Modul 1: operation brakes/pneumatics system upper-carriage parking brake only opened after signal CLOSE B
function is not carried out
196661 E/A-Modul 1: operation hydraulics/second. power outputs secondary output pump not engaged as engine ON B
function is not carried out
196662 E/A-Modul 1: operation hydraulics/second. power outputs secondary output pump not disengaged as engine ON B
function is not carried out
196663 E/A-Modul 1: operation hydraulics/second. power outputs secondary output pump not switchable as engine ON B
function is not carried out
196703 E/A-Modul 1: operation off-road gear operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)
070645 130
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
196704 E/A-Modul 1: operation off-road gear operation from upper-carriage with under-carriage operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)
196705 E/A-Modul 1: operation off-road gear operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to uppercarriage operation mode
196706 E/A-Modul 1: operation off-road gear operation from upper-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection to E/A-Modul 2
196707 E/A-Modul 1: operation off-road gear operation from under-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection to E/A-Modul 2
196775 E/A-Modul 1: operation off-road gear off-road gear and transfer box free in upper-carriage operation mode B
function is not carried out
do not disconnect transfer case in off-road gear ON or off-road gear not ON with disconnection of transfer gear
196776 E/A-Modul 1: operation off-road gear off-road gear and transfer box free in under-carriage operation mode B
function is not carried out
do not disconnect transfer case in off-road gear ON or off-road gear not ON with disconnection of transfer gear
196778 E/A-Modul 1: operation off-road gear speed too high for off-road gear B
function is not carried out
reduce speed
196779 E/A-Modul 1: operation off-road gear off-road gear ON and gears not neutral B
function is not carried out
switch transmission to neutral (N)
197030 E/A-Modul 1: operation heating/air.conditioning switching on air-conditioning only possible with engine running B
function is not carried out
start engine and repeat operation
197182 E/A-Modul 1: operation lighting indicator from upper-carriage in under-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to uppercarriage operation mode
070645 131
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
197183 E/A-Modul 1: operation lighting indicator from under-carriage in upper-carriage operation mode B
function is not carried out
switch off undercarriage indicator
197185 E/A-Modul 1: operation lighting hazard lights from upper-carriage and under-carriage B
function is not carried out
switch off warning light
197186 E/A-Modul 1: operation lighting rear fog lamp only with light B
function is not carried out
switch on full beam, dipped light or fog light
199890 E/A-Modul 1: operation diagnosis system test program not executable as engine is not OFF B
function is not carried out
199892 E/A-Modul 1: operation diagnosis system test program not executable as not in under-carriage op. mode B
function is not carried out
199895 E/A-Modul 1: operation diagnosis system start not possible as gears not in neutral B
function is not carried out
199922 E/A-Modul 1: operation optional device function not available in under-carriage operation mode B
function is not carried out
on customers request
199924 E/A-Modul 1: operation optional device no customized function in under-carriage operation mode B
function is not carried out
on customers request
070645 132
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
200001 ZE 2: system error OS-HC11 (observe parameters) initialising error processor-register erroneous E 2
no crane operation possible
if error re-occurs, then ZE should be replaced
200002 ZE 2: system error OS-HC11 (observe parameters) initialising error test total in EPROM/FLASH erroneous E 2
no crane operation possible
check program memory card or ZE
200006 ZE 2: system error OS-HC11 (observe parameters) initialising error RAM erroneous E 2
no crane operation possible
if error re-occurs, then ZE should be replaced
200013 ZE 2: system error OS-HC11 (observe parameters) Test sum in FLASH erroneous E 2
entry in error memory, all crane movements will be stopped
check program memory card
070645 133
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
200017 ZE 2: system error OS-HC11 (observe parameters) total of CPU-time distribution too great E 2
entry in error memory, all crane movements will be stopped
200018 ZE 2: system error OS-HC11 (observe parameters) arithmetic overflow (16 Bit) E 2
entry in error memory, all crane movements will be stopped
200019 ZE 2: system error OS-HC11 (observe parameters) division through zero (16 Bit) E 2
entry in error memory, all crane movements will be stopped
200023 ZE 2: system error OS-HC11 (observe parameters) program incapable of running (type identification) E 2
entry in error memory, all crane movements will be stopped
070645 134
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
200044 ZE 2: system error OS-HC11 (observe parameters) output parameter without effect, from inactive output E 2
entry in error memory, all crane movements will be stopped
200045 ZE 2: system error OS-HC11 (observe parameters) entry parameter undefined, from inactive input E 2
entry in error memory, all crane movements will be stopped
200047 ZE 2: system error OS-HC11 (observe parameters) realtime-control block not available E 2
entry in error memory, all crane movements will be stopped
200049 ZE 2: system error OS-HC11 (observe parameters) urgent modul, ZE not available E 2
entry in error memory, no crane operation possible
check ZE
070645 135
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
200052 ZE 2: system error OS-HC11 (observe parameters) file not open on close E 2
entry in error memory, all crane movements will be stopped
200053 ZE 2: system error OS-HC11 (observe parameters) system mask not available E 2
entry in error memory, all crane movements will be stopped
200054 ZE 2: system error OS-HC11 (observe parameters) system text not available E 2
entry in error memory, all crane movements will be stopped
200057 ZE 2: system error OS-HC11 (observe parameters) default load chart missing E 2
entry in error memory, all crane movements will be stopped
200058 ZE 2: system error OS-HC11 (observe parameters) amplifier erroneous or return power feed E 2
entry in error memory, all crane movements will be stopped
check wiring
070645 136
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
200066 ZE 2: system error OS-HC11 (observe parameters) ADC working outside the permissible tolerance E 2
entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced
200067 ZE 2: system error OS-HC11 (observe parameters) arithmetic processor not available E 2
entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced
200071 ZE 2: system error OS-HC11 (observe parameters) Structure file missing or faulty E 2
entry in error memory, no crane operation possible
070645 137
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
200074 ZE 2: system error OS-HC11 (observe parameters) transformation ASCII to BIN erroneous E 2
entry in error memory, all crane movements will be stopped
200076 ZE 2: system error OS-HC11 (observe parameters) incorrectly inserted power unit E 2
entry in error memory, all crane movements will be stopped
check memory card in power supply unit
070645 138
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
200094 ZE 2: system error OS-HC11 (observe parameters) transmission error parallel bus E 2
entry in error memory, all crane movements will be stopped
check ZE, bus circuit board, power supply unit
202002 ZE 2: system error OS-TMS initialising error test total in EPROM/FLASH erroneous E 2
entry of error in error memory, all crane movements will be stopped
replace ZE
070645 139
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
210060 ZE 2: output 0 safety chain error, diode defect or safety contact sticking X72:16 E 1
report of error, otherwise no reaction
checking of safety contact and diode
070645 140
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
210160 ZE 2: output 1 safety chain error, diode defect or safety contact sticking X72:17 E 1
report of error, otherwise no reaction
checking of safety contact and diode
070645 141
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
070645 142
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
210360 ZE 2: output 3 safety chain error, diode defect or safety contact sticking X72:19 E 1
report of error, otherwise no reaction
checking of safety contact and diode
070645 143
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
210460 ZE 2: output 4 safety chain error, diode defect or safety contact sticking X72:20 E 1
report of error, otherwise no reaction
checking of safety contact and diode
070645 144
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
210560 ZE 2: output 5 safety chain error, diode defect or safety contact sticking X72:21 E 1
report of error, otherwise no reaction
checking of safety contact and diode
070645 145
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
210660 ZE 2: output 6 safety chain error, diode defect or safety contact sticking X72:22 E 1
report of error, otherwise no reaction
checking of safety contact and diode
070645 146
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
210760 ZE 2: output 7 safety chain error, diode defect or safety contact sticking X72:23 E 1
report of error, otherwise no reaction
checking of safety contact and diode
070645 147
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
220051 ZE 2: LSB participant address 0 was not configured for the block transfer X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
220053 ZE 2: LSB participant address 0 no longer reports or withdrawn during running period X635B:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
070645 148
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
220054 ZE 2: LSB participant address 0 Features other settings (parameters) as pre-entered set values X635B:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
220066 ZE 2: LSB participant address 0 with software version, that is no longer compatible X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
220151 ZE 2: LSB participant address 1 was not configured for the block transfer X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
070645 149
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
220153 ZE 2: LSB participant address 1 no longer reports or withdrawn during running period X635B:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
220154 ZE 2: LSB participant address 1 Features other settings (parameters) as pre-entered set values X635B:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
220166 ZE 2: LSB participant address 1 with software version, that is no longer compatible X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 150
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
220251 ZE 2: LSB participant address 2 was not configured for the block transfer X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
220253 ZE 2: LSB participant address 2 no longer reports or withdrawn during running period X635B:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
220254 ZE 2: LSB participant address 2 Features other settings (parameters) as pre-entered set values X635B:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
220266 ZE 2: LSB participant address 2 with software version, that is no longer compatible X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 151
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
220951 ZE 2: LSB participant address 9 was not configured for the block transfer X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
220953 ZE 2: LSB participant address 9 no longer reports or withdrawn during running period X635B:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
220954 ZE 2: LSB participant address 9 Features other settings (parameters) as pre-entered set values X635B:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
220966 ZE 2: LSB participant address 9 with software version, that is no longer compatible X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 152
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
222151 ZE 2: LSB participant address 21 was not configured for the block transfer X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
222153 ZE 2: LSB participant address 21 no longer reports or withdrawn during running period X635B:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
222154 ZE 2: LSB participant address 21 Features other settings (parameters) as pre-entered set values X635B:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
222166 ZE 2: LSB participant address 21 with software version, that is no longer compatible X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 153
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
222351 ZE 2: LSB participant address 23 was not configured for the block transfer X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
222353 ZE 2: LSB participant address 23 no longer reports or withdrawn during running period X635B:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
222354 ZE 2: LSB participant address 23 Features other settings (parameters) as pre-entered set values X635B:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
222366 ZE 2: LSB participant address 23 with software version, that is no longer compatible X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 154
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
222451 ZE 2: LSB participant address 24 was not configured for the block transfer X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
222453 ZE 2: LSB participant address 24 no longer reports or withdrawn during running period X635B:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
222454 ZE 2: LSB participant address 24 Features other settings (parameters) as pre-entered set values X635B:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
222466 ZE 2: LSB participant address 24 with software version, that is no longer compatible X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 155
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
222651 ZE 2: LSB participant address 26 was not configured for the block transfer X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
222653 ZE 2: LSB participant address 26 no longer reports or withdrawn during running period X635B:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
222654 ZE 2: LSB participant address 26 Features other settings (parameters) as pre-entered set values X635B:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
070645 156
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
222666 ZE 2: LSB participant address 26 with software version, that is no longer compatible X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
222751 ZE 2: LSB participant address 27 was not configured for the block transfer X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
222753 ZE 2: LSB participant address 27 no longer reports or withdrawn during running period X635B:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
222754 ZE 2: LSB participant address 27 Features other settings (parameters) as pre-entered set values X635B:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
070645 157
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
222766 ZE 2: LSB participant address 27 with software version, that is no longer compatible X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
222851 ZE 2: LSB participant address 28 was not configured for the block transfer X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
222853 ZE 2: LSB participant address 28 no longer reports or withdrawn during running period X635B:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
222854 ZE 2: LSB participant address 28 Features other settings (parameters) as pre-entered set values X635B:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
070645 158
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
222866 ZE 2: LSB participant address 28 with software version, that is no longer compatible X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
222951 ZE 2: LSB participant address 29 was not configured for the block transfer X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
222953 ZE 2: LSB participant address 29 no longer reports or withdrawn during running period X635B:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
070645 159
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
222954 ZE 2: LSB participant address 29 Features other settings (parameters) as pre-entered set values X635B:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
222966 ZE 2: LSB participant address 29 with software version, that is no longer compatible X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
223252 ZE 2: Control data transfer LSB has recognised Bus collisions, communication interrupted X635B:z14/z16 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor
223255 ZE 2: Control data transfer LSB Bus connection faulty/defect, short circuit to supply voltage X635B:z14/z16 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
223256 ZE 2: Control data transfer LSB Bus connection faulty/defect, no supply/short circuit to earth X635B:z14/z16 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
223257 ZE 2: Control data transfer LSB has recognised network re-set (data transfer starts again) X635B:z14/z16 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part
223258 ZE 2: Control data transfer LSB recognised participant with incorrect baud rate in bus X635B:z14/z16 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors
070645 160
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
223259 ZE 2: Control data transfer LSB recognised communication breakdown in bus X635B:z14/z16 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network
223260 ZE 2: Control data transfer LSB driver error: no order to carry out X635B:z14/z16 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software
223261 ZE 2: Control data transfer LSB driver error: undefined message appears X635B:z14/z16 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination
223262 ZE 2: Control data transfer LSB Driver error: Initialization error X635B:z14/z16 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination
225702 ZE 2: input 9 sensor deficiency data short circuit to supply voltage X635B:d20 E 1
report of error, otherwise no reaction
check supply, LICCON input, sensor lines to short or break, sensor
230500 ZE 2: remote control transmit, maximum transmission cycle radio contact exceeded E 1
radio control deactivated
check radio receiver/-transmitter (battery!)
070645 161
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
233901 ZE 2: crane control Signal current engine momentum - Maximum erroneous / missing E 1
output of error, a medium torque will now be adjusted for the output limitation
check engine electronics, with permanent error contact after-sales service
234824 ZE 2: control diagnosis system Charge press. hoist gear or press. switch'Lower freely'faulty/not pre E 1
Carrying out of test program delayed / interrupted
Check charge pressure, carry out test program again
070645 162
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
234830 ZE 2: control diagnosis system Pressure cut-off pump outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check pressure reduction and pressure limitation LS, carry out test program again
234831 ZE 2: control diagnosis system Pressure cut-off hoist gear lift outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check pressure hoist gear, carry out test program again
234832 ZE 2: control diagnosis system Pressure cut-off hoist gear lower outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check pressure hoist gear, carry out test program again
234846 ZE 2: control diagnosis system Initial current winch lift above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
234847 ZE 2: control diagnosis system Initial current winch lift below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
234848 ZE 2: control diagnosis system Initial current winch lower above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
234849 ZE 2: control diagnosis system Initial current winch lower below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
070645 163
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
070645 164
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
070645 165
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
236100 ZE 2: Operation ballasting / counterweight carriage Counterweight UP selected, final position not started B 1
report of error, otherwise no reaction
Approach end position, if ok check: -supply, -input LICCON, -sensor line for short-circuit or interruption, -
236101 ZE 2: Operation ballasting / counterweight carriage Counterweight DOWN selected, final position not started B 1
report of error, otherwise no reaction
Approach end position, if ok check: -supply, -input LICCON, -sensor line for short-circuit or interruption, -
236144 ZE 2: Operation ballasting / counterweight carriage Shut-off crane engine not running B
237200 ZE 2: operation instruments armrest right master switch 1Y not in neutral when starting B 1
output of error, shut-down through application
release master switch briefly or check LICCON input, gear lines, sensor
237201 ZE 2: operation instruments armrest right master switch 1X not in neutral when starting B 1
output of error, shut-down through application
release master switch briefly or check LICCON input, gear lines, sensor
237312 ZE 2: operation instruments armrest left master switch 2Y not in neutral when starting B 1
output of error, shut-down through application
release master switch briefly or check LICCON input, gear lines, sensor
239800 ZE 2: operation diagnosis system interruption, master switch defective or incorrectly deflected B 1
Carrying out of test program delayed / interrupted
Note direction of movements, carry out test program again
070645 166
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
239814 ZE 2: operation diagnosis system Alignment aid not correctly shut down B 1
Invalid operation condition, no proper crane operation possible
Apply F key, end active test program
239820 ZE 2: operation diagnosis system interruption, boom angle beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Extend to correct luffing position, carry out test program again
239821 ZE 2: operation diagnosis system interruption, tele length beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Extend to correct telescopic boom length length, carry out test program again
239822 ZE 2: operation diagnosis system interruption, hook load beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Note max. hook load, carry out test program again
261002 E/A-Modul 2: system error OS-C167 initialising error test total in EPROM/FLASH erroneous E 2
error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul
070645 167
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
261088 E/A-Modul 2: system error OS-C167 Configuration does not match software condition E 1
Error output, possible error functions of module
Carry out EAM-download from LICCON
272052 E/A-Modul 2: input/output DEA0 output open, to low load, short circuit to supply voltage X623:17 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
070645 168
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
272053 E/A-Modul 2: input/output DEA0 transistor current supply insufficient or missing X623:17 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
272055 E/A-Modul 2: input/output DEA0 excessive temperature, short circuit to ground or overload X623:17 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
272152 E/A-Modul 2: input/output DEA1 output open, to low load, short circuit to supply voltage X623:15 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
272153 E/A-Modul 2: input/output DEA1 transistor current supply insufficient or missing X623:15 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
272155 E/A-Modul 2: input/output DEA1 excessive temperature, short circuit to ground or overload X623:15 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
272252 E/A-Modul 2: input/output DEA2 output open, to low load, short circuit to supply voltage X623:13 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
272253 E/A-Modul 2: input/output DEA2 transistor current supply insufficient or missing X623:13 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
070645 169
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
272255 E/A-Modul 2: input/output DEA2 excessive temperature, short circuit to ground or overload X623:13 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
272352 E/A-Modul 2: input/output DEA3 output open, to low load, short circuit to supply voltage X623:11 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
272353 E/A-Modul 2: input/output DEA3 transistor current supply insufficient or missing X623:11 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
272355 E/A-Modul 2: input/output DEA3 excessive temperature, short circuit to ground or overload X623:11 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
272452 E/A-Modul 2: input/output DEA4 output open, to low load, short circuit to supply voltage X623:9 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
272453 E/A-Modul 2: input/output DEA4 transistor current supply insufficient or missing X623:9 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
272455 E/A-Modul 2: input/output DEA4 excessive temperature, short circuit to ground or overload X623:9 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
272552 E/A-Modul 2: input/output DEA5 output open, to low load, short circuit to supply voltage X623:7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
070645 170
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
272553 E/A-Modul 2: input/output DEA5 transistor current supply insufficient or missing X623:7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
272555 E/A-Modul 2: input/output DEA5 excessive temperature, short circuit to ground or overload X623:7 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
272652 E/A-Modul 2: input/output DEA6 output open, to low load, short circuit to supply voltage X623:5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
272653 E/A-Modul 2: input/output DEA6 transistor current supply insufficient or missing X623:5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
272655 E/A-Modul 2: input/output DEA6 excessive temperature, short circuit to ground or overload X623:5 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
272752 E/A-Modul 2: input/output DEA7 output open, to low load, short circuit to supply voltage X623:3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
272753 E/A-Modul 2: input/output DEA7 transistor current supply insufficient or missing X623:3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
070645 171
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
272755 E/A-Modul 2: input/output DEA7 excessive temperature, short circuit to ground or overload X623:3 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
273481 E/A-Modul 2: voltage input E4 short circuit to supply voltage, open line X622:9 E 1
symbol for compressed air supply 1 is flashing on the display unit
check input signal on the E/A-Modul or sensor
273581 E/A-Modul 2: voltage input E5 short circuit to supply voltage, open line X622:7 E 1
symbol for compressed air supply 2 is flashing on the display unit
check input signal on the E/A-Modul or sensor
273681 E/A-Modul 2: voltage input E6 short circuit to supply voltage, open line X622:5 E 1
symbol for compressed air supply 3 is flashing on the display unit
check input signal on the E/A-Modul or sensor
273782 E/A-Modul 2: voltage input E7 short circuit to ground, open line, constant current 10 mA incorrect X622:3 E 1
no reaction
check input signal on the E/A-Modul or sensor
273783 E/A-Modul 2: voltage input E7 short circuit to supply voltage, open line, lack of voltage X622:3 E 1
no reaction
check input signal on the E/A-Modul or sensor
279052 E/A-Modul 2: output A0 output open, to low load, short circuit to supply voltage X623:18 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
279055 E/A-Modul 2: output A0 excessive temperature, short circuit to ground or overload X623:18 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
070645 172
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
279152 E/A-Modul 2: output A1 output open, to low load, short circuit to supply voltage X623:16 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
279155 E/A-Modul 2: output A1 excessive temperature, short circuit to ground or overload X623:16 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
279250 E/A-Modul 2: bridge output A2 short circuit to ground, junction not supplied X623:14 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul
279251 E/A-Modul 2: bridge output A2 short circuit to supply voltage, excessive temperature X623:14 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul
279252 E/A-Modul 2: bridge output A2 output open, to low load, short circuit to supply voltage X623:14 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
279253 E/A-Modul 2: bridge output A2 transistor current supply insufficient or missing X623:14 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
279255 E/A-Modul 2: bridge output A2 excessive temperature, short circuit to ground or overload X623:14 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
070645 173
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
279350 E/A-Modul 2: bridge output A3 short circuit to ground, junction not supplied X623:12 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul
279351 E/A-Modul 2: bridge output A3 short circuit to supply voltage, excessive temperature X623:12 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul
279352 E/A-Modul 2: bridge output A3 output open, to low load, short circuit to supply voltage X623:12 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
279353 E/A-Modul 2: bridge output A3 transistor current supply insufficient or missing X623:12 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
279355 E/A-Modul 2: bridge output A3 excessive temperature, short circuit to ground or overload X623:12 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
283301 E/A-Modul 2: SPI-display unit Faulty data transfer E/A-module<>unit (time exceeded) X624:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul
283302 E/A-Modul 2: SPI-display unit Serious system error to SPI-connection (interface) X624:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul
283303 E/A-Modul 2: SPI-display unit break in line or short circuit to supply voltage X624:1/2/3/5/6/ E 1
error indication on display 7/8
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary
283304 E/A-Modul 2: SPI-display unit break in line or short circuit to ground X624:1/2/3/5/6/ E 1
error indication on display 7/8
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary
070645 174
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
283306 E/A-Modul 2: SPI-display unit Data transfer faulty (faulty check byte) X624:1/2/3/5/6/ E 1
error indication on display 7/8
suppress EMV- interference
283307 E/A-Modul 2: SPI-display unit Unit faulty/missing, incorrect unit inserted (ID) X624:1/2/3/5/6/ E 1
error indication on display 7/8
check periphery and replace if necessary, check Software version, check EMV- interference
283308 E/A-Modul 2: SPI-display unit Data transfer faulty (incorrect number of data bytes received) X624:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul
283900 E/A-Modul 2: Control operating unit (SPI) Faulty initialisation data connection E/A-module<>unit X624:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul
283902 E/A-Modul 2: Control operating unit (SPI) Serious system error to SPI-connection (interface) X624:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul
283905 E/A-Modul 2: Control operating unit (SPI) Initialisation error, resetting inputs/outputs faulty X624:1/2/3/5/6/ E 1
error indication on display 7/8
check wiring, check periphery and replace if necessary, check E/A-Modul and replace if necessary
283907 E/A-Modul 2: Control operating unit (SPI) Unit faulty/missing, incorrect unit inserted (ID) X624:1/2/3/5/6/ E 1
error indication on display 7/8
connect functional periphery unit, system then eliminates error independently
283908 E/A-Modul 2: Control operating unit (SPI) Data transfer faulty (incorrect number of data bytes received) X624:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul
070645 175
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
284150 E/A-Modul 2: LSB-B participant address 1 reports an incorrect sensor type X623:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
284151 E/A-Modul 2: LSB-B participant address 1 was not configured for the block transfer X623:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
284153 E/A-Modul 2: LSB-B participant address 1 no longer reports or withdrawn during running period X623:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
284154 E/A-Modul 2: LSB-B participant address 1 Features other settings (parameters) as pre-entered set values X623:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
284164 E/A-Modul 2: LSB-B participant address 1 reports tolerable error in self-test X623:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
284165 E/A-Modul 2: LSB-B participant address 1 reports intolerable error in self-test X623:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
284166 E/A-Modul 2: LSB-B participant address 1 with software version, that is no longer compatible X623:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 176
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
284250 E/A-Modul 2: LSB-B participant address 2 reports an incorrect sensor type X623:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
284251 E/A-Modul 2: LSB-B participant address 2 was not configured for the block transfer X623:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
284253 E/A-Modul 2: LSB-B participant address 2 no longer reports or withdrawn during running period X623:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
284254 E/A-Modul 2: LSB-B participant address 2 Features other settings (parameters) as pre-entered set values X623:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
284264 E/A-Modul 2: LSB-B participant address 2 reports tolerable error in self-test X623:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
284265 E/A-Modul 2: LSB-B participant address 2 reports intolerable error in self-test X623:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
284266 E/A-Modul 2: LSB-B participant address 2 with software version, that is no longer compatible X623:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 177
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
284350 E/A-Modul 2: LSB-B participant address 3 reports an incorrect sensor type X623:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
284351 E/A-Modul 2: LSB-B participant address 3 was not configured for the block transfer X623:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
284353 E/A-Modul 2: LSB-B participant address 3 no longer reports or withdrawn during running period X623:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
284354 E/A-Modul 2: LSB-B participant address 3 Features other settings (parameters) as pre-entered set values X623:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
284364 E/A-Modul 2: LSB-B participant address 3 reports tolerable error in self-test X623:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
284365 E/A-Modul 2: LSB-B participant address 3 reports intolerable error in self-test X623:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
284366 E/A-Modul 2: LSB-B participant address 3 with software version, that is no longer compatible X623:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 178
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
284450 E/A-Modul 2: LSB-B participant address 4 reports an incorrect sensor type X623:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
284451 E/A-Modul 2: LSB-B participant address 4 was not configured for the block transfer X623:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
284453 E/A-Modul 2: LSB-B participant address 4 no longer reports or withdrawn during running period X623:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
284454 E/A-Modul 2: LSB-B participant address 4 Features other settings (parameters) as pre-entered set values X623:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
284464 E/A-Modul 2: LSB-B participant address 4 reports tolerable error in self-test X623:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
284465 E/A-Modul 2: LSB-B participant address 4 reports intolerable error in self-test X623:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
070645 179
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
284466 E/A-Modul 2: LSB-B participant address 4 with software version, that is no longer compatible X623:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
284550 E/A-Modul 2: LSB-B participant address 5 reports an incorrect sensor type X623:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
284551 E/A-Modul 2: LSB-B participant address 5 was not configured for the block transfer X623:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
284553 E/A-Modul 2: LSB-B participant address 5 no longer reports or withdrawn during running period X623:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
284554 E/A-Modul 2: LSB-B participant address 5 Features other settings (parameters) as pre-entered set values X623:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
284564 E/A-Modul 2: LSB-B participant address 5 reports tolerable error in self-test X623:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
070645 180
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
284565 E/A-Modul 2: LSB-B participant address 5 reports intolerable error in self-test X623:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
284566 E/A-Modul 2: LSB-B participant address 5 with software version, that is no longer compatible X623:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
284650 E/A-Modul 2: LSB-B participant address 6 reports an incorrect sensor type X623:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
284651 E/A-Modul 2: LSB-B participant address 6 was not configured for the block transfer X623:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
284653 E/A-Modul 2: LSB-B participant address 6 no longer reports or withdrawn during running period X623:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
284654 E/A-Modul 2: LSB-B participant address 6 Features other settings (parameters) as pre-entered set values X623:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
070645 181
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
284664 E/A-Modul 2: LSB-B participant address 6 reports tolerable error in self-test X623:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
284665 E/A-Modul 2: LSB-B participant address 6 reports intolerable error in self-test X623:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
284666 E/A-Modul 2: LSB-B participant address 6 with software version, that is no longer compatible X623:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
286650 E/A-Modul 2: LSB-B participant address 26 reports an incorrect sensor type X623:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
286651 E/A-Modul 2: LSB-B participant address 26 was not configured for the block transfer X623:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
286653 E/A-Modul 2: LSB-B participant address 26 no longer reports or withdrawn during running period X623:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
070645 182
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
286654 E/A-Modul 2: LSB-B participant address 26 Features other settings (parameters) as pre-entered set values X623:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
286664 E/A-Modul 2: LSB-B participant address 26 reports tolerable error in self-test X623:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
286665 E/A-Modul 2: LSB-B participant address 26 reports intolerable error in self-test X623:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
286666 E/A-Modul 2: LSB-B participant address 26 with software version, that is no longer compatible X623:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
286750 E/A-Modul 2: LSB-B participant address 27 reports an incorrect sensor type X623:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
286751 E/A-Modul 2: LSB-B participant address 27 was not configured for the block transfer X623:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
070645 183
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
286753 E/A-Modul 2: LSB-B participant address 27 no longer reports or withdrawn during running period X623:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
286754 E/A-Modul 2: LSB-B participant address 27 Features other settings (parameters) as pre-entered set values X623:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
286764 E/A-Modul 2: LSB-B participant address 27 reports tolerable error in self-test X623:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
286765 E/A-Modul 2: LSB-B participant address 27 reports intolerable error in self-test X623:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
286766 E/A-Modul 2: LSB-B participant address 27 with software version, that is no longer compatible X623:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
286850 E/A-Modul 2: LSB-B participant address 28 reports an incorrect sensor type X623:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
070645 184
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
286851 E/A-Modul 2: LSB-B participant address 28 was not configured for the block transfer X623:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
286853 E/A-Modul 2: LSB-B participant address 28 no longer reports or withdrawn during running period X623:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
286854 E/A-Modul 2: LSB-B participant address 28 Features other settings (parameters) as pre-entered set values X623:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
286864 E/A-Modul 2: LSB-B participant address 28 reports tolerable error in self-test X623:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
286865 E/A-Modul 2: LSB-B participant address 28 reports intolerable error in self-test X623:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
286866 E/A-Modul 2: LSB-B participant address 28 with software version, that is no longer compatible X623:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 185
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
286950 E/A-Modul 2: LSB-B participant address 29 reports an incorrect sensor type X623:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
286951 E/A-Modul 2: LSB-B participant address 29 was not configured for the block transfer X623:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
286953 E/A-Modul 2: LSB-B participant address 29 no longer reports or withdrawn during running period X623:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
286954 E/A-Modul 2: LSB-B participant address 29 Features other settings (parameters) as pre-entered set values X623:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
286964 E/A-Modul 2: LSB-B participant address 29 reports tolerable error in self-test X623:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
286965 E/A-Modul 2: LSB-B participant address 29 reports intolerable error in self-test X623:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
286966 E/A-Modul 2: LSB-B participant address 29 with software version, that is no longer compatible X623:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
287252 E/A-Modul 2: Control data transfer LSB-B has recognised Bus collisions, communication interrupted X623:4/6 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor
287255 E/A-Modul 2: Control data transfer LSB-B Bus connection faulty/defect, short circuit to supply voltage X623:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
070645 186
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
287256 E/A-Modul 2: Control data transfer LSB-B Bus connection faulty/defect, no supply/short circuit to earth X623:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
287257 E/A-Modul 2: Control data transfer LSB-B has recognised network re-set (data transfer starts again) X623:4/6 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part
287258 E/A-Modul 2: Control data transfer LSB-B recognised participant with incorrect baud rate in bus X623:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors
287259 E/A-Modul 2: Control data transfer LSB-B recognised communication breakdown in bus X623:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network
287260 E/A-Modul 2: Control data transfer LSB-B driver error: no order to carry out X623:4/6 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software
287261 E/A-Modul 2: Control data transfer LSB-B driver error: undefined message appears X623:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination
287262 E/A-Modul 2: Control data transfer LSB-B Driver error: Initialization error X623:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination
287530 E/A-Modul 2: CAN-participant engine Data transfer subscriber transfer cycle exceeded X625:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant
287531 E/A-Modul 2: CAN-participant engine Data transfer faulty/missing, max. cycle time exceeded X625:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant
287630 E/A-Modul 2: CAN-participant gear Data transfer subscriber transfer cycle exceeded X625:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul
070645 187
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
287631 E/A-Modul 2: CAN-participant gear Data transfer faulty/missing, max. cycle time exceeded X625:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
287730 E/A-Modul 2: CAN-participant ABV (ABS/ASR) Data transfer subscriber transfer cycle exceeded X625:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul
287731 E/A-Modul 2: CAN-participant ABV (ABS/ASR) Data transfer faulty/missing, max. cycle time exceeded X625:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
287930 E/A-Modul 2: CAN-participant retarder Data transfer subscriber transfer cycle exceeded X625:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul
287931 E/A-Modul 2: CAN-participant retarder Data transfer faulty/missing, max. cycle time exceeded X625:5/6 E 1
parameterised substitute values for receiver signals will be used
Check CAN network, check faulty Bus user.
288030 E/A-Modul 2: CAN-user converter clutch unit CCU Data transfer subscriber transfer cycle exceeded X625:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul
288031 E/A-Modul 2: CAN-user converter clutch unit CCU Data transfer faulty/missing, max. cycle time exceeded X625:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
288530 E/A-Modul 2: CAN-participant E/A-Modul 1 Data transfer subscriber transfer cycle exceeded X625:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant
288531 E/A-Modul 2: CAN-participant E/A-Modul 1 Data transfer faulty/missing, max. cycle time exceeded X625:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
288630 E/A-Modul 2: CAN-participant E/A-Modul 2 Data transfer subscriber transfer cycle exceeded X625:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant
070645 188
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
288631 E/A-Modul 2: CAN-participant E/A-Modul 2 Data transfer faulty/missing, max. cycle time exceeded X625:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
288930 E/A-Modul 2: CAN-participant E/A-Modul 5 Data transfer subscriber transfer cycle exceeded X625:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant
288931 E/A-Modul 2: CAN-participant E/A-Modul 5 Data transfer faulty/missing, max. cycle time exceeded X625:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
289900 E/A-Modul 2: Control data transfer CAN internal error at Register-check Controller X625:5/6 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul
289901 E/A-Modul 2: Control data transfer CAN internal error at RAM-check Controller X625:5/6 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul
289902 E/A-Modul 2: Control data transfer CAN Configuration error Software X625:5/6 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul, check Software (test system ZE)
289903 E/A-Modul 2: Control data transfer CAN Transfer interrupted after continuous error X625:5/6 E 1
CAN-Transmission will be aborted
check bus lines/neutral point, replace neutral point or E/A-Modul
289910 E/A-Modul 2: Control data transfer CAN short-term error in bus connection X625:5/6 E 0
re-attachment of Modul to bus transmission
check bus lines/neutral point, unplug individual bus participant and check if error has been eliminated
289911 E/A-Modul 2: Control data transfer CAN permanent error bus connection X625:5/6 E 1
cyclic re-attachment of Modul to bus transmission
check bus lines/neutral point, unplug individual bus participant and check if error has been eliminated
289920 E/A-Modul 2: Control data transfer CAN active participant not responding X625:5/6 E 0
parameterised substitute values for receiver signals will be used
check error report for missing participant(s), test system ZE
070645 189
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
289921 E/A-Modul 2: Control data transfer CAN No active subscriber responding X625:5/6 E 1
parameterised substitute values for receiver signals will be used
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul
289950 E/A-Modul 2: Control data transfer CAN erroneous command test system X625:5/6 E 1
no reaction to unknown test system control command in CAN-System Software
check Software (test system)
292001 E/A-Modul 2: control engine long-term disruption E/A-Modul <-> engine control E 1
engine control and E/A-Modul at emergency speed
engine control and E/A-Modul, check CAN-bus-connections
293038 E/A-Modul 2: control hydraulic/second. power outputs feedback secondary output pump active missing E 1
in case the pump is mechanically engaged; operation is possible
check pneumatic engagement mechanism of pump, sensor position; if necessary engage by hand with engine off
293039 E/A-Modul 2: control hydraulic/second. power outputs feedback secondary output pump inactive missing E 1
in case the pump is mechanically engaged, pump can be damaged in travel operation due to excessive speed
pneumatic engagement mechanism of the pump, check sensor position; if nec. disengage pump manually with engine off
293500 E/A-Modul 2: control heating/air conditioning servo-motor heating, circulated/fresh air or screen/foot erroneous E 1
servo motor relays a high signal to the diagnosis output
check water valve and air flaps of the heating or check servo motor
070645 190
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
294943 E/A-Modul 2: control optional device no signal from boom sensor in support E 1
control indicator for boom support flashing
check LSB-bus connection, check sensor
295050 E/A-Modul 2: operation engine no engine start possible as engine already recognized as ON B
function is not carried out
295055 E/A-Modul 2: operation engine STOP, ignition operators cab in upper-carriage operation mode B
function is not carried out
295056 E/A-Modul 2: operation engine STOP, ignition operators cab in under-carriage operation mode B
function is not carried out
295059 E/A-Modul 2: operation engine no start, CAN-connection E/A-Modul <-> engine elec. malfunc B
function is not carried out
295063 E/A-Modul 2: operation engine no start, engine-STOP-key activated in right support unit B
function is not carried out
070645 191
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
295064 E/A-Modul 2: operation engine no start, engine-STOP-key activated in left support unit B
function is not carried out
295079 E/A-Modul 2: operation engine support box-operation mode prevented: gears not in neutral B
function is not carried out
295080 E/A-Modul 2: operation engine travel operation not possible when key activated on support box B
function is not carried out
070645 192
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
295914 E/A-Modul 2: operation longitudinal lock activation of function without operation mode B
function is not carried out
start engine and repeat operation
296660 E/A-Modul 2: operation hydraulics/second. power outputs secondary output pump not engaged as compr. air supply too low B
function is not carried out
296663 E/A-Modul 2: operation hydraulics/second. power outputs secondary output pump not switchable as engine ON B
function is not carried out
296666 E/A-Modul 2: operation hydraulics/second. power outputs hyd. crane system pump not engaged as compr. air supply too low B
function is not carried out
296777 E/A-Modul 2: operation off-road gear Clear distributor gear active or no report B
function is not carried out
do not disconnect transfer case in off-road gear ON or off-road gear not ON with disconnection of transfer gear
300001 ZE 3: system error OS-HC11 (observe parameters) initialising error processor-register erroneous E 2
no crane operation possible
if error re-occurs, then ZE should be replaced
300002 ZE 3: system error OS-HC11 (observe parameters) initialising error test total in EPROM/FLASH erroneous E 2
no crane operation possible
check program memory card or ZE
300006 ZE 3: system error OS-HC11 (observe parameters) initialising error RAM erroneous E 2
no crane operation possible
if error re-occurs, then ZE should be replaced
070645 193
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
300013 ZE 3: system error OS-HC11 (observe parameters) Test sum in FLASH erroneous E 2
entry in error memory, all crane movements will be stopped
check program memory card
300017 ZE 3: system error OS-HC11 (observe parameters) total of CPU-time distribution too great E 2
entry in error memory, all crane movements will be stopped
300018 ZE 3: system error OS-HC11 (observe parameters) arithmetic overflow (16 Bit) E 2
entry in error memory, all crane movements will be stopped
300019 ZE 3: system error OS-HC11 (observe parameters) division through zero (16 Bit) E 2
entry in error memory, all crane movements will be stopped
070645 194
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
300023 ZE 3: system error OS-HC11 (observe parameters) program incapable of running (type identification) E 2
entry in error memory, all crane movements will be stopped
300044 ZE 3: system error OS-HC11 (observe parameters) output parameter without effect, from inactive output E 2
entry in error memory, all crane movements will be stopped
070645 195
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
300045 ZE 3: system error OS-HC11 (observe parameters) entry parameter undefined, from inactive input E 2
entry in error memory, all crane movements will be stopped
300047 ZE 3: system error OS-HC11 (observe parameters) realtime-control block not available E 2
entry in error memory, all crane movements will be stopped
300049 ZE 3: system error OS-HC11 (observe parameters) urgent modul, ZE not available E 2
entry in error memory, no crane operation possible
check ZE
300052 ZE 3: system error OS-HC11 (observe parameters) file not open on close E 2
entry in error memory, all crane movements will be stopped
300053 ZE 3: system error OS-HC11 (observe parameters) system mask not available E 2
entry in error memory, all crane movements will be stopped
300054 ZE 3: system error OS-HC11 (observe parameters) system text not available E 2
entry in error memory, all crane movements will be stopped
070645 196
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
300057 ZE 3: system error OS-HC11 (observe parameters) default load chart missing E 2
entry in error memory, all crane movements will be stopped
300058 ZE 3: system error OS-HC11 (observe parameters) amplifier erroneous or return power feed E 2
entry in error memory, all crane movements will be stopped
check wiring
070645 197
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
300066 ZE 3: system error OS-HC11 (observe parameters) ADC working outside the permissible tolerance E 2
entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced
300067 ZE 3: system error OS-HC11 (observe parameters) arithmetic processor not available E 2
entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced
300071 ZE 3: system error OS-HC11 (observe parameters) Structure file missing or faulty E 2
entry in error memory, no crane operation possible
300074 ZE 3: system error OS-HC11 (observe parameters) transformation ASCII to BIN erroneous E 2
entry in error memory, all crane movements will be stopped
300076 ZE 3: system error OS-HC11 (observe parameters) incorrectly inserted power unit E 2
entry in error memory, all crane movements will be stopped
check memory card in power supply unit
070645 198
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
300094 ZE 3: system error OS-HC11 (observe parameters) transmission error parallel bus E 2
entry in error memory, all crane movements will be stopped
check ZE, bus circuit board, power supply unit
070645 199
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
302002 ZE 3: system error OS-TMS initialising error test total in EPROM/FLASH erroneous E 2
entry of error in error memory, all crane movements will be stopped
replace ZE
070645 200
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
310060 ZE 3: output 0 safety chain error, diode defect or safety contact sticking X73:16 E 1
report of error, otherwise no reaction
checking of safety contact and diode
070645 201
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
310160 ZE 3: output 1 safety chain error, diode defect or safety contact sticking X73:17 E 1
report of error, otherwise no reaction
checking of safety contact and diode
070645 202
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
070645 203
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
310460 ZE 3: output 4 safety chain error, diode defect or safety contact sticking X73:20 E 1
report of error, otherwise no reaction
checking of safety contact and diode
070645 204
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
310560 ZE 3: output 5 safety chain error, diode defect or safety contact sticking X73:21 E 1
report of error, otherwise no reaction
checking of safety contact and diode
070645 205
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
070645 206
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
310760 ZE 3: output 7 safety chain error, diode defect or safety contact sticking X73:23 E 1
report of error, otherwise no reaction
checking of safety contact and diode
070645 207
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
070645 208
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
320051 ZE 3: LSB participant address 0 was not configured for the block transfer X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
320053 ZE 3: LSB participant address 0 no longer reports or withdrawn during running period X635C:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
320054 ZE 3: LSB participant address 0 Features other settings (parameters) as pre-entered set values X635C:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
320066 ZE 3: LSB participant address 0 with software version, that is no longer compatible X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 209
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
320151 ZE 3: LSB participant address 1 was not configured for the block transfer X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
320153 ZE 3: LSB participant address 1 no longer reports or withdrawn during running period X635C:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
320154 ZE 3: LSB participant address 1 Features other settings (parameters) as pre-entered set values X635C:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
320166 ZE 3: LSB participant address 1 with software version, that is no longer compatible X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 210
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
320951 ZE 3: LSB participant address 9 was not configured for the block transfer X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
320953 ZE 3: LSB participant address 9 no longer reports or withdrawn during running period X635C:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
320954 ZE 3: LSB participant address 9 Features other settings (parameters) as pre-entered set values X635C:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
320966 ZE 3: LSB participant address 9 with software version, that is no longer compatible X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 211
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
321051 ZE 3: LSB participant address 10 was not configured for the block transfer X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
321053 ZE 3: LSB participant address 10 no longer reports or withdrawn during running period X635C:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
321054 ZE 3: LSB participant address 10 Features other settings (parameters) as pre-entered set values X635C:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
070645 212
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
321066 ZE 3: LSB participant address 10 with software version, that is no longer compatible X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
321151 ZE 3: LSB participant address 11 was not configured for the block transfer X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
321153 ZE 3: LSB participant address 11 no longer reports or withdrawn during running period X635C:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
321154 ZE 3: LSB participant address 11 Features other settings (parameters) as pre-entered set values X635C:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
070645 213
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
321166 ZE 3: LSB participant address 11 with software version, that is no longer compatible X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
321251 ZE 3: LSB participant address 12 was not configured for the block transfer X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
321253 ZE 3: LSB participant address 12 no longer reports or withdrawn during running period X635C:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
321254 ZE 3: LSB participant address 12 Features other settings (parameters) as pre-entered set values X635C:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
070645 214
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
321266 ZE 3: LSB participant address 12 with software version, that is no longer compatible X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
321351 ZE 3: LSB participant address 13 was not configured for the block transfer X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
321353 ZE 3: LSB participant address 13 no longer reports or withdrawn during running period X635C:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
070645 215
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
321354 ZE 3: LSB participant address 13 Features other settings (parameters) as pre-entered set values X635C:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
321366 ZE 3: LSB participant address 13 with software version, that is no longer compatible X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
321451 ZE 3: LSB participant address 14 was not configured for the block transfer X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
070645 216
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
321453 ZE 3: LSB participant address 14 no longer reports or withdrawn during running period X635C:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
321454 ZE 3: LSB participant address 14 Features other settings (parameters) as pre-entered set values X635C:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
321466 ZE 3: LSB participant address 14 with software version, that is no longer compatible X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 217
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
321551 ZE 3: LSB participant address 15 was not configured for the block transfer X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
321553 ZE 3: LSB participant address 15 no longer reports or withdrawn during running period X635C:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
321554 ZE 3: LSB participant address 15 Features other settings (parameters) as pre-entered set values X635C:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
321566 ZE 3: LSB participant address 15 with software version, that is no longer compatible X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 218
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
321651 ZE 3: LSB participant address 16 was not configured for the block transfer X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
321653 ZE 3: LSB participant address 16 no longer reports or withdrawn during running period X635C:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
321654 ZE 3: LSB participant address 16 Features other settings (parameters) as pre-entered set values X635C:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
321666 ZE 3: LSB participant address 16 with software version, that is no longer compatible X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 219
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
322151 ZE 3: LSB participant address 21 was not configured for the block transfer X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
322153 ZE 3: LSB participant address 21 no longer reports or withdrawn during running period X635C:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
322154 ZE 3: LSB participant address 21 Features other settings (parameters) as pre-entered set values X635C:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
322166 ZE 3: LSB participant address 21 with software version, that is no longer compatible X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 220
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
322251 ZE 3: LSB participant address 22 was not configured for the block transfer X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
322253 ZE 3: LSB participant address 22 no longer reports or withdrawn during running period X635C:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
322254 ZE 3: LSB participant address 22 Features other settings (parameters) as pre-entered set values X635C:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
322266 ZE 3: LSB participant address 22 with software version, that is no longer compatible X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 221
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
322851 ZE 3: LSB participant address 28 was not configured for the block transfer X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
322853 ZE 3: LSB participant address 28 no longer reports or withdrawn during running period X635C:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
322854 ZE 3: LSB participant address 28 Features other settings (parameters) as pre-entered set values X635C:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
322866 ZE 3: LSB participant address 28 with software version, that is no longer compatible X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 222
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
323252 ZE 3: Control data transfer LSB has recognised Bus collisions, communication interrupted X635C:z14/z16 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor
323255 ZE 3: Control data transfer LSB Bus connection faulty/defect, short circuit to supply voltage X635C:z14/z16 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
323256 ZE 3: Control data transfer LSB Bus connection faulty/defect, no supply/short circuit to earth X635C:z14/z16 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
323257 ZE 3: Control data transfer LSB has recognised network re-set (data transfer starts again) X635C:z14/z16 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part
323258 ZE 3: Control data transfer LSB recognised participant with incorrect baud rate in bus X635C:z14/z16 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors
323259 ZE 3: Control data transfer LSB recognised communication breakdown in bus X635C:z14/z16 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network
323260 ZE 3: Control data transfer LSB driver error: no order to carry out X635C:z14/z16 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software
323261 ZE 3: Control data transfer LSB driver error: undefined message appears X635C:z14/z16 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination
323262 ZE 3: Control data transfer LSB Driver error: Initialization error X635C:z14/z16 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination
070645 223
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
333029 ZE 3: control auxiliary equipment Switch "Hose drum brake open" switched or short circuit E 1
Telescoping is shut off
Fix short circuit
070645 224
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
335112 ZE 3: operation winch 2 shut-down as lower fly jib and NA-boom 3 not positioned B
Operation conditional switch off, may not be shunted
reel winch in until limit switch is no longer actuated - shut-down cannot be shunted
335113 ZE 3: operation winch 2 shut-down as flap not positioned and angle threshold exceeded B
Operation conditional switch off, may not be shunted
check as to why the flap is not in position - shut-down cannot be shunted
335114 ZE 3: operation winch 2 pressure retaining cylinder RFP N shut-down outside set range B
Operation conditional switch off, may not be shunted
Wind off winch until pressure is once again within the desired range - shut-down may not be shunted .
335116 ZE 3: operation winch 2 luffing up accessory shut-down working area limitation ABB B
operational shut down
reel winch out until crane in working area again - shunting through shutting down of working area limitation
335117 ZE 3: operation winch 2 luffing down accessory shut-down working area limitation ABB B
operational shut down
reel winch in until crane in working area again - shunting through shutting down of working area limitation
070645 225
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
335161 ZE 3: operation winch 2 Winch shut-down not mounted or incompletely / incorrectly mounted B
operational shut down
Release master switch - check pin on winch frame
335170 ZE 3: operation winch 2 shut-down both limit switches "flap in position" defect./missing B
Operation conditional switch off, may not be shunted
release master switch - error elimination see corresponding system error
070645 226
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
335171 ZE 3: operation winch 2 shut-down both limit switches "NA-boom 3 pos." defect./missing B
Operation conditional switch off, may not be shunted
release master switch - error elimination see corresponding system error
335172 ZE 3: operation winch 2 shut-down both angle sensors "fly jib" defective/missing B
Operation conditional switch off, may not be shunted
release master switch - error elimination see corresponding system error
335173 ZE 3: operation winch 2 shut-down both limit switches "lower fly jib" defective/missing B
Operation conditional switch off, may not be shunted
release master switch - error elimination see corresponding system error
335174 ZE 3: operation winch 2 shut-down both limit switches "upper fly jib flap" defect./missing B
Operation conditional switch off, may not be shunted
release master switch - error elimination see corresponding system error
335175 ZE 3: operation winch 2 shut-down both limit switches "upper fly jib stop"defect./missing B
Operation conditional switch off, may not be shunted
release master switch - error elimination see corresponding system error
335184 ZE 3: operation winch 2 shut-down both limit switches "transp. setting N" defect./missing B
070645 227
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
336018 ZE 3: operation additional equipment Shut-off incorrect operation type, incorrectly set up or not sold B 1
336029 ZE 3: operation additional equipment Button "Spool hose drum up / out" is stuck or actuated during start B 1
operational shut down
Release button or fix short circuit
361002 E/A-Modul 3: system error OS-C167 initialising error test total in EPROM/FLASH erroneous E 2
error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul
070645 228
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
361088 E/A-Modul 3: system error OS-C167 Configuration does not match software condition E 1
Error output, possible error functions of module
Carry out EAM-download from LICCON
372052 E/A-Modul 3: input/output DEA0 output open, to low load, short circuit to supply voltage X633:17 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
372053 E/A-Modul 3: input/output DEA0 transistor current supply insufficient or missing X633:17 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
372055 E/A-Modul 3: input/output DEA0 excessive temperature, short circuit to ground or overload X633:17 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
070645 229
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
372152 E/A-Modul 3: input/output DEA1 output open, to low load, short circuit to supply voltage X633:15 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
372153 E/A-Modul 3: input/output DEA1 transistor current supply insufficient or missing X633:15 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
372155 E/A-Modul 3: input/output DEA1 excessive temperature, short circuit to ground or overload X633:15 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
372252 E/A-Modul 3: input/output DEA2 output open, to low load, short circuit to supply voltage X633:13 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
372253 E/A-Modul 3: input/output DEA2 transistor current supply insufficient or missing X633:13 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
372255 E/A-Modul 3: input/output DEA2 excessive temperature, short circuit to ground or overload X633:13 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
372352 E/A-Modul 3: input/output DEA3 output open, to low load, short circuit to supply voltage X633:11 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
372353 E/A-Modul 3: input/output DEA3 transistor current supply insufficient or missing X633:11 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
070645 230
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
372355 E/A-Modul 3: input/output DEA3 excessive temperature, short circuit to ground or overload X633:11 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
372452 E/A-Modul 3: input/output DEA4 output open, to low load, short circuit to supply voltage X633:9 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
372453 E/A-Modul 3: input/output DEA4 transistor current supply insufficient or missing X633:9 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
372455 E/A-Modul 3: input/output DEA4 excessive temperature, short circuit to ground or overload X633:9 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
372552 E/A-Modul 3: input/output DEA5 output open, to low load, short circuit to supply voltage X633:7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
372553 E/A-Modul 3: input/output DEA5 transistor current supply insufficient or missing X633:7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
372555 E/A-Modul 3: input/output DEA5 excessive temperature, short circuit to ground or overload X633:7 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
070645 231
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
372652 E/A-Modul 3: input/output DEA6 output open, to low load, short circuit to supply voltage X633:5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
372653 E/A-Modul 3: input/output DEA6 transistor current supply insufficient or missing X633:5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
372655 E/A-Modul 3: input/output DEA6 excessive temperature, short circuit to ground or overload X633:5 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
372752 E/A-Modul 3: input/output DEA7 output open, to low load, short circuit to supply voltage X633:3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
372753 E/A-Modul 3: input/output DEA7 transistor current supply insufficient or missing X633:3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
372755 E/A-Modul 3: input/output DEA7 excessive temperature, short circuit to ground or overload X633:3 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
373080 E/A-Modul 3: current input E0 short circuit to ground, open line, voltage sensor erroneous X632:17 E 1
on both support operating units "E." is flashing on the display for support force front right
check input signal on the E/A-Modul or sensor
070645 232
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
373180 E/A-Modul 3: current input E1 short circuit to ground, open line, voltage sensor erroneous X632:15 E 1
on both support operating units "E." is flashing on the display for support force rear right
check input signal on the E/A-Modul or sensor
373280 E/A-Modul 3: current input E2 short circuit to ground, open line, voltage sensor erroneous X632:13 E 1
both outer LEDs for transversal inclination on both support operating units are flashing
check input signal on the E/A-Modul or sensor
373380 E/A-Modul 3: current input E3 short circuit to ground, open line, voltage sensor erroneous X632:11 E 1
both outer LEDs for longitudinal inclination are flashing on both support units
check input signal on the E/A-Modul or sensor
373782 E/A-Modul 3: voltage input E7 short circuit to ground, open line, constant current 10 mA incorrect X632:3 E 1
symbol for diesel tank is flashing on the display unit, as are 3 question marks on monitor in uppercarriage
check input signal on the E/A-Modul or sensor
373783 E/A-Modul 3: voltage input E7 short circuit to supply voltage, open line, lack of voltage X632:3 E 1
symbol for diesel tank is flashing on the display unit, as are 3 question marks on monitor in uppercarriage
check input signal on the E/A-Modul or sensor
379052 E/A-Modul 3: output A0 output open, to low load, short circuit to supply voltage X633:18 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
070645 233
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
379055 E/A-Modul 3: output A0 excessive temperature, short circuit to ground or overload X633:18 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
379152 E/A-Modul 3: output A1 output open, to low load, short circuit to supply voltage X633:16 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
379155 E/A-Modul 3: output A1 excessive temperature, short circuit to ground or overload X633:16 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
379250 E/A-Modul 3: bridge output A2 short circuit to ground, junction not supplied X633:14 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul
379251 E/A-Modul 3: bridge output A2 short circuit to supply voltage, excessive temperature X633:14 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul
379252 E/A-Modul 3: bridge output A2 output open, to low load, short circuit to supply voltage X633:14 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
379253 E/A-Modul 3: bridge output A2 transistor current supply insufficient or missing X633:14 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
070645 234
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
379255 E/A-Modul 3: bridge output A2 excessive temperature, short circuit to ground or overload X633:14 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
379350 E/A-Modul 3: bridge output A3 short circuit to ground, junction not supplied X633:12 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul
379351 E/A-Modul 3: bridge output A3 short circuit to supply voltage, excessive temperature X633:12 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul
379352 E/A-Modul 3: bridge output A3 output open, to low load, short circuit to supply voltage X633:12 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
379353 E/A-Modul 3: bridge output A3 transistor current supply insufficient or missing X633:12 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
379355 E/A-Modul 3: bridge output A3 excessive temperature, short circuit to ground or overload X633:12 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
383501 E/A-Modul 3: SPI-support unit right Faulty data transfer E/A-module<>unit (time exceeded) X634:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul
383502 E/A-Modul 3: SPI-support unit right Serious system error to SPI-connection (interface) X634:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul
070645 235
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
383503 E/A-Modul 3: SPI-support unit right break in line or short circuit to supply voltage X634:1/2/3/5/6/ E 1
error indication on display 7/8
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary
383504 E/A-Modul 3: SPI-support unit right break in line or short circuit to ground X634:1/2/3/5/6/ E 1
error indication on display 7/8
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary
383506 E/A-Modul 3: SPI-support unit right Data transfer faulty (faulty check byte) X634:1/2/3/5/6/ E 1
error indication on display 7/8
suppress EMV- interference
383507 E/A-Modul 3: SPI-support unit right Unit faulty/missing, incorrect unit inserted (ID) X634:1/2/3/5/6/ E 1
error indication on display 7/8
check periphery and replace if necessary, check Software version, check EMV- interference
383508 E/A-Modul 3: SPI-support unit right Data transfer faulty (incorrect number of data bytes received) X634:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul
383900 E/A-Modul 3: Control operating unit (SPI) Faulty initialisation data connection E/A-module<>unit X634:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul
383902 E/A-Modul 3: Control operating unit (SPI) Serious system error to SPI-connection (interface) X634:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul
383905 E/A-Modul 3: Control operating unit (SPI) Initialisation error, resetting inputs/outputs faulty X634:1/2/3/5/6/ E 1
error indication on display 7/8
check wiring, check periphery and replace if necessary, check E/A-Modul and replace if necessary
383907 E/A-Modul 3: Control operating unit (SPI) Unit faulty/missing, incorrect unit inserted (ID) X634:1/2/3/5/6/ E 1
error indication on display 7/8
connect functional periphery unit, system then eliminates error independently
383908 E/A-Modul 3: Control operating unit (SPI) Data transfer faulty (incorrect number of data bytes received) X634:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul
070645 236
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
384150 E/A-Modul 3: LSB-B participant address 1 reports an incorrect sensor type X633:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
384151 E/A-Modul 3: LSB-B participant address 1 was not configured for the block transfer X633:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
384153 E/A-Modul 3: LSB-B participant address 1 no longer reports or withdrawn during running period X633:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
384154 E/A-Modul 3: LSB-B participant address 1 Features other settings (parameters) as pre-entered set values X633:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
384164 E/A-Modul 3: LSB-B participant address 1 reports tolerable error in self-test X633:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
384165 E/A-Modul 3: LSB-B participant address 1 reports intolerable error in self-test X633:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
384166 E/A-Modul 3: LSB-B participant address 1 with software version, that is no longer compatible X633:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 237
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
384250 E/A-Modul 3: LSB-B participant address 2 reports an incorrect sensor type X633:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
384251 E/A-Modul 3: LSB-B participant address 2 was not configured for the block transfer X633:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
384253 E/A-Modul 3: LSB-B participant address 2 no longer reports or withdrawn during running period X633:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
384254 E/A-Modul 3: LSB-B participant address 2 Features other settings (parameters) as pre-entered set values X633:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
384264 E/A-Modul 3: LSB-B participant address 2 reports tolerable error in self-test X633:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
384265 E/A-Modul 3: LSB-B participant address 2 reports intolerable error in self-test X633:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
070645 238
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
384266 E/A-Modul 3: LSB-B participant address 2 with software version, that is no longer compatible X633:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
384350 E/A-Modul 3: LSB-B participant address 3 reports an incorrect sensor type X633:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
384351 E/A-Modul 3: LSB-B participant address 3 was not configured for the block transfer X633:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
384353 E/A-Modul 3: LSB-B participant address 3 no longer reports or withdrawn during running period X633:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
384354 E/A-Modul 3: LSB-B participant address 3 Features other settings (parameters) as pre-entered set values X633:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
384364 E/A-Modul 3: LSB-B participant address 3 reports tolerable error in self-test X633:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
070645 239
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
384365 E/A-Modul 3: LSB-B participant address 3 reports intolerable error in self-test X633:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
384366 E/A-Modul 3: LSB-B participant address 3 with software version, that is no longer compatible X633:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
384450 E/A-Modul 3: LSB-B participant address 4 reports an incorrect sensor type X633:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
384451 E/A-Modul 3: LSB-B participant address 4 was not configured for the block transfer X633:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
384453 E/A-Modul 3: LSB-B participant address 4 no longer reports or withdrawn during running period X633:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
384454 E/A-Modul 3: LSB-B participant address 4 Features other settings (parameters) as pre-entered set values X633:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
070645 240
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
384464 E/A-Modul 3: LSB-B participant address 4 reports tolerable error in self-test X633:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
384465 E/A-Modul 3: LSB-B participant address 4 reports intolerable error in self-test X633:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
384466 E/A-Modul 3: LSB-B participant address 4 with software version, that is no longer compatible X633:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
384550 E/A-Modul 3: LSB-B participant address 5 reports an incorrect sensor type X633:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
384551 E/A-Modul 3: LSB-B participant address 5 was not configured for the block transfer X633:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
384553 E/A-Modul 3: LSB-B participant address 5 no longer reports or withdrawn during running period X633:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
070645 241
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
384554 E/A-Modul 3: LSB-B participant address 5 Features other settings (parameters) as pre-entered set values X633:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
384564 E/A-Modul 3: LSB-B participant address 5 reports tolerable error in self-test X633:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
384565 E/A-Modul 3: LSB-B participant address 5 reports intolerable error in self-test X633:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
384566 E/A-Modul 3: LSB-B participant address 5 with software version, that is no longer compatible X633:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
384650 E/A-Modul 3: LSB-B participant address 6 reports an incorrect sensor type X633:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
384651 E/A-Modul 3: LSB-B participant address 6 was not configured for the block transfer X633:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
070645 242
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
384653 E/A-Modul 3: LSB-B participant address 6 no longer reports or withdrawn during running period X633:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
384654 E/A-Modul 3: LSB-B participant address 6 Features other settings (parameters) as pre-entered set values X633:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
384664 E/A-Modul 3: LSB-B participant address 6 reports tolerable error in self-test X633:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
384665 E/A-Modul 3: LSB-B participant address 6 reports intolerable error in self-test X633:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
384666 E/A-Modul 3: LSB-B participant address 6 with software version, that is no longer compatible X633:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
387252 E/A-Modul 3: Control data transfer LSB-B has recognised Bus collisions, communication interrupted X633:4/6 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor
387255 E/A-Modul 3: Control data transfer LSB-B Bus connection faulty/defect, short circuit to supply voltage X633:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
387256 E/A-Modul 3: Control data transfer LSB-B Bus connection faulty/defect, no supply/short circuit to earth X633:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
387257 E/A-Modul 3: Control data transfer LSB-B has recognised network re-set (data transfer starts again) X633:4/6 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part
070645 243
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
387258 E/A-Modul 3: Control data transfer LSB-B recognised participant with incorrect baud rate in bus X633:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors
387259 E/A-Modul 3: Control data transfer LSB-B recognised communication breakdown in bus X633:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network
387260 E/A-Modul 3: Control data transfer LSB-B driver error: no order to carry out X633:4/6 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software
387261 E/A-Modul 3: Control data transfer LSB-B driver error: undefined message appears X633:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination
387262 E/A-Modul 3: Control data transfer LSB-B Driver error: Initialization error X633:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination
392510 E/A-Modul 3: control axle suspension/level signals from transfer contact "axle elevated" simultaneous IN E 1
raise axles 3+4 function defective, function can be carried out with defective feedback
change-contact pressure switch >120 bar, Check cabling to short against supply voltage
392511 E/A-Modul 3: control axle suspension/level signals from transfer contact "axle elevated" simultaneous OUT E 1
raise axles 3+4 function defective, function can be carried out with defective feedback
change-contact pressure switch >120 bar, check cabling for wire break, fuse Kl.15
392830 E/A-Modul 3: control supports location coding for right support unit erroneous (set value = 0) E 2
support functions are blocked
check line connection to E/A-Modul, check ground connection from signal, replace E/A-Modul
392832 E/A-Modul 3: control supports right support unit key sticking or activated after switching on E 1
right support blocked
check/unplug/replace support operating unit release activated key
070645 244
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
396440 E/A-Modul 3: operation supports simultaneous UP and DOWN operation of support control unit B
function is not carried out
actuate UP key or DOWN key of the respective support operating unit, start test program support service unit
396441 E/A-Modul 3: operation supports simultaneous IN and OUT operation of support control unit B
function is not carried out
actuate OFF key or ON key of the respective support operating unit, start test program support operating unit
396442 E/A-Modul 3: operation supports simultaneous UP and DOWN operation on upper-carriage monitor B
function is not carried out
actuate UP key or DOWN key of the respective support operating unit, start test program support service unit
396443 E/A-Modul 3: operation supports simultaneous IN and OUT operation on upper-carriage monitor B
function is not carried out
actuate OFF key or ON key of the respective support operating unit, start test program support operating unit
070645 245
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
396444 E/A-Modul 3: operation supports simultaneous left and right operation of support control unit B
function is not carried out
actuate support from only one operating position, start test program support operating unit
396445 E/A-Modul 3: operation supports simultaneous operation of support control unit and upper-carriage B
function is not carried out
actuate support from only one operating position, start test program support operating unit
396446 E/A-Modul 3: operation supports simultaneous operation of support control unit and upper-carriage B
function is not carried out
actuate support from only one operating position, start test program support operating unit
396447 E/A-Modul 3: operation supports operation of support control unit with travel direction D engaged B
function is not carried out
switch transmission to neutral (N)
396448 E/A-Modul 3: operation supports operation of support control unit with travel direction R engaged B
function is not carried out
switch transmission to neutral (N)
396449 E/A-Modul 3: operation supports op. of upper-carriage monitor with travel direction D engaged B
function is not carried out
switch transmission to neutral (N)
399890 E/A-Modul 3: operation diagnosis system test program not executable as engine is not OFF B
function is not carried out
shut down engine
399892 E/A-Modul 3: operation diagnosis system test program not executable as not in under-carriage op. mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode
070645 246
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
402002 ZE 4: system error OS-TMS initialising error test total in EPROM/FLASH erroneous E 2
entry of error in error memory, all crane movements will be stopped
replace ZE
461002 E/A-Modul 4: system error OS-C167 initialising error test total in EPROM/FLASH erroneous E 2
error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul
070645 247
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
461088 E/A-Modul 4: system error OS-C167 Configuration does not match software condition E 1
Error output, possible error functions of module
Carry out EAM-download from LICCON
472052 E/A-Modul 4: input/output DEA0 output open, to low load, short circuit to supply voltage X643:17 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
472053 E/A-Modul 4: input/output DEA0 transistor current supply insufficient or missing X643:17 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
070645 248
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
472055 E/A-Modul 4: input/output DEA0 excessive temperature, short circuit to ground or overload X643:17 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
472152 E/A-Modul 4: input/output DEA1 output open, to low load, short circuit to supply voltage X643:15 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
472153 E/A-Modul 4: input/output DEA1 transistor current supply insufficient or missing X643:15 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
472155 E/A-Modul 4: input/output DEA1 excessive temperature, short circuit to ground or overload X643:15 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
472252 E/A-Modul 4: input/output DEA2 output open, to low load, short circuit to supply voltage X643:13 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
472253 E/A-Modul 4: input/output DEA2 transistor current supply insufficient or missing X643:13 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
472255 E/A-Modul 4: input/output DEA2 excessive temperature, short circuit to ground or overload X643:13 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
070645 249
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
472352 E/A-Modul 4: input/output DEA3 output open, to low load, short circuit to supply voltage X643:11 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
472353 E/A-Modul 4: input/output DEA3 transistor current supply insufficient or missing X643:11 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
472355 E/A-Modul 4: input/output DEA3 excessive temperature, short circuit to ground or overload X643:11 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
472452 E/A-Modul 4: input/output DEA4 output open, to low load, short circuit to supply voltage X643:9 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
472453 E/A-Modul 4: input/output DEA4 transistor current supply insufficient or missing X643:9 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
472455 E/A-Modul 4: input/output DEA4 excessive temperature, short circuit to ground or overload X643:9 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
472552 E/A-Modul 4: input/output DEA5 output open, to low load, short circuit to supply voltage X643:7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
472553 E/A-Modul 4: input/output DEA5 transistor current supply insufficient or missing X643:7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
070645 250
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
472555 E/A-Modul 4: input/output DEA5 excessive temperature, short circuit to ground or overload X643:7 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
472652 E/A-Modul 4: input/output DEA6 output open, to low load, short circuit to supply voltage X643:5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
472653 E/A-Modul 4: input/output DEA6 transistor current supply insufficient or missing X643:5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
472655 E/A-Modul 4: input/output DEA6 excessive temperature, short circuit to ground or overload X643:5 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
472752 E/A-Modul 4: input/output DEA7 output open, to low load, short circuit to supply voltage X643:3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
472753 E/A-Modul 4: input/output DEA7 transistor current supply insufficient or missing X643:3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
472755 E/A-Modul 4: input/output DEA7 excessive temperature, short circuit to ground or overload X643:3 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
070645 251
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
473080 E/A-Modul 4: current input E0 short circuit to ground, open line, voltage sensor erroneous X642:17 E 1
on both support operating units "E." is flashing on the display for support force front left
check input signal on the E/A-Modul or sensor
473180 E/A-Modul 4: current input E1 short circuit to ground, open line, voltage sensor erroneous X642:15 E 1
on both support operating units "E." is flashing on the display for support force rear left
check input signal on the E/A-Modul or sensor
479052 E/A-Modul 4: output A0 output open, to low load, short circuit to supply voltage X643:18 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
479055 E/A-Modul 4: output A0 excessive temperature, short circuit to ground or overload X643:18 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
479152 E/A-Modul 4: output A1 output open, to low load, short circuit to supply voltage X643:16 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
070645 252
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
479155 E/A-Modul 4: output A1 excessive temperature, short circuit to ground or overload X643:16 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
479250 E/A-Modul 4: bridge output A2 short circuit to ground, junction not supplied X643:14 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul
479251 E/A-Modul 4: bridge output A2 short circuit to supply voltage, excessive temperature X643:14 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul
479252 E/A-Modul 4: bridge output A2 output open, to low load, short circuit to supply voltage X643:14 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
479253 E/A-Modul 4: bridge output A2 transistor current supply insufficient or missing X643:14 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
479255 E/A-Modul 4: bridge output A2 excessive temperature, short circuit to ground or overload X643:14 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
479350 E/A-Modul 4: bridge output A3 short circuit to ground, junction not supplied X643:12 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul
479351 E/A-Modul 4: bridge output A3 short circuit to supply voltage, excessive temperature X643:12 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul
070645 253
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
479352 E/A-Modul 4: bridge output A3 output open, to low load, short circuit to supply voltage X643:12 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
479353 E/A-Modul 4: bridge output A3 transistor current supply insufficient or missing X643:12 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
479355 E/A-Modul 4: bridge output A3 excessive temperature, short circuit to ground or overload X643:12 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
483601 E/A-Modul 4: SPI-support unit left Faulty data transfer E/A-module<>unit (time exceeded) X644:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul
483602 E/A-Modul 4: SPI-support unit left Serious system error to SPI-connection (interface) X644:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul
483603 E/A-Modul 4: SPI-support unit left break in line or short circuit to supply voltage X644:1/2/3/5/6/ E 1
error indication on display 7/8
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary
483604 E/A-Modul 4: SPI-support unit left break in line or short circuit to ground X644:1/2/3/5/6/ E 1
error indication on display 7/8
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary
483606 E/A-Modul 4: SPI-support unit left Data transfer faulty (faulty check byte) X644:1/2/3/5/6/ E 1
error indication on display 7/8
suppress EMV- interference
483607 E/A-Modul 4: SPI-support unit left Unit faulty/missing, incorrect unit inserted (ID) X644:1/2/3/5/6/ E 1
error indication on display 7/8
check periphery and replace if necessary, check Software version, check EMV- interference
070645 254
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
483608 E/A-Modul 4: SPI-support unit left Data transfer faulty (incorrect number of data bytes received) X644:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul
483900 E/A-Modul 4: Control operating unit (SPI) Faulty initialisation data connection E/A-module<>unit X644:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul
483902 E/A-Modul 4: Control operating unit (SPI) Serious system error to SPI-connection (interface) X644:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul
483905 E/A-Modul 4: Control operating unit (SPI) Initialisation error, resetting inputs/outputs faulty X644:1/2/3/5/6/ E 1
error indication on display 7/8
check wiring, check periphery and replace if necessary, check E/A-Modul and replace if necessary
483907 E/A-Modul 4: Control operating unit (SPI) Unit faulty/missing, incorrect unit inserted (ID) X644:1/2/3/5/6/ E 1
error indication on display 7/8
connect functional periphery unit, system then eliminates error independently
483908 E/A-Modul 4: Control operating unit (SPI) Data transfer faulty (incorrect number of data bytes received) X644:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul
484150 E/A-Modul 4: LSB-B participant address 1 reports an incorrect sensor type X643:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
070645 255
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
484151 E/A-Modul 4: LSB-B participant address 1 was not configured for the block transfer X643:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
484153 E/A-Modul 4: LSB-B participant address 1 no longer reports or withdrawn during running period X643:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
484154 E/A-Modul 4: LSB-B participant address 1 Features other settings (parameters) as pre-entered set values X643:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
484164 E/A-Modul 4: LSB-B participant address 1 reports tolerable error in self-test X643:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
484165 E/A-Modul 4: LSB-B participant address 1 reports intolerable error in self-test X643:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
484166 E/A-Modul 4: LSB-B participant address 1 with software version, that is no longer compatible X643:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 256
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
484250 E/A-Modul 4: LSB-B participant address 2 reports an incorrect sensor type X643:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
484251 E/A-Modul 4: LSB-B participant address 2 was not configured for the block transfer X643:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
484253 E/A-Modul 4: LSB-B participant address 2 no longer reports or withdrawn during running period X643:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
484254 E/A-Modul 4: LSB-B participant address 2 Features other settings (parameters) as pre-entered set values X643:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
484264 E/A-Modul 4: LSB-B participant address 2 reports tolerable error in self-test X643:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
484265 E/A-Modul 4: LSB-B participant address 2 reports intolerable error in self-test X643:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
484266 E/A-Modul 4: LSB-B participant address 2 with software version, that is no longer compatible X643:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 257
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
484350 E/A-Modul 4: LSB-B participant address 3 reports an incorrect sensor type X643:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
484351 E/A-Modul 4: LSB-B participant address 3 was not configured for the block transfer X643:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
484353 E/A-Modul 4: LSB-B participant address 3 no longer reports or withdrawn during running period X643:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
484354 E/A-Modul 4: LSB-B participant address 3 Features other settings (parameters) as pre-entered set values X643:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
484364 E/A-Modul 4: LSB-B participant address 3 reports tolerable error in self-test X643:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
484365 E/A-Modul 4: LSB-B participant address 3 reports intolerable error in self-test X643:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
484366 E/A-Modul 4: LSB-B participant address 3 with software version, that is no longer compatible X643:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 258
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
484450 E/A-Modul 4: LSB-B participant address 4 reports an incorrect sensor type X643:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
484451 E/A-Modul 4: LSB-B participant address 4 was not configured for the block transfer X643:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
484453 E/A-Modul 4: LSB-B participant address 4 no longer reports or withdrawn during running period X643:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
484454 E/A-Modul 4: LSB-B participant address 4 Features other settings (parameters) as pre-entered set values X643:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
484464 E/A-Modul 4: LSB-B participant address 4 reports tolerable error in self-test X643:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
484465 E/A-Modul 4: LSB-B participant address 4 reports intolerable error in self-test X643:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
484466 E/A-Modul 4: LSB-B participant address 4 with software version, that is no longer compatible X643:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 259
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
484550 E/A-Modul 4: LSB-B participant address 5 reports an incorrect sensor type X643:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
484551 E/A-Modul 4: LSB-B participant address 5 was not configured for the block transfer X643:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
484553 E/A-Modul 4: LSB-B participant address 5 no longer reports or withdrawn during running period X643:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
484554 E/A-Modul 4: LSB-B participant address 5 Features other settings (parameters) as pre-entered set values X643:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
484564 E/A-Modul 4: LSB-B participant address 5 reports tolerable error in self-test X643:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
484565 E/A-Modul 4: LSB-B participant address 5 reports intolerable error in self-test X643:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
484566 E/A-Modul 4: LSB-B participant address 5 with software version, that is no longer compatible X643:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 260
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
484650 E/A-Modul 4: LSB-B participant address 6 reports an incorrect sensor type X643:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
484651 E/A-Modul 4: LSB-B participant address 6 was not configured for the block transfer X643:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
484653 E/A-Modul 4: LSB-B participant address 6 no longer reports or withdrawn during running period X643:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
484654 E/A-Modul 4: LSB-B participant address 6 Features other settings (parameters) as pre-entered set values X643:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
484664 E/A-Modul 4: LSB-B participant address 6 reports tolerable error in self-test X643:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
484665 E/A-Modul 4: LSB-B participant address 6 reports intolerable error in self-test X643:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
070645 261
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
484666 E/A-Modul 4: LSB-B participant address 6 with software version, that is no longer compatible X643:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
487252 E/A-Modul 4: Control data transfer LSB-B has recognised Bus collisions, communication interrupted X643:4/6 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor
487255 E/A-Modul 4: Control data transfer LSB-B Bus connection faulty/defect, short circuit to supply voltage X643:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
487256 E/A-Modul 4: Control data transfer LSB-B Bus connection faulty/defect, no supply/short circuit to earth X643:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
487257 E/A-Modul 4: Control data transfer LSB-B has recognised network re-set (data transfer starts again) X643:4/6 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part
487258 E/A-Modul 4: Control data transfer LSB-B recognised participant with incorrect baud rate in bus X643:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors
487259 E/A-Modul 4: Control data transfer LSB-B recognised communication breakdown in bus X643:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network
487260 E/A-Modul 4: Control data transfer LSB-B driver error: no order to carry out X643:4/6 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software
487261 E/A-Modul 4: Control data transfer LSB-B driver error: undefined message appears X643:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination
070645 262
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
487262 E/A-Modul 4: Control data transfer LSB-B Driver error: Initialization error X643:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination
492747 E/A-Modul 4: control steering signal from steering pump flow switch erroneous E 1
control indicator for steering pump flashing
check line connections, power supply 10 mA from E/A-Modul; replace sensor or E/A-Modul
492748 E/A-Modul 4: control steering signal from auxiliary steering pump flow switch erroneous E 1
control indicator for auxiliary steering pump flashing
check line connections, power supply 10 mA from E/A-Modul; replace sensor or E/A-Modul
492831 E/A-Modul 4: control supports location coding for left support unit erroneous (set value = 1) E 2
support functions are blocked
check line connection to E/A-Modul, check power supply from signal, replace E/A-Modul
492833 E/A-Modul 4: control supports left support unit key sticking or activated after switching on E 1
left support blocked
check/unplug/replace support operating unit release activated key
070645 263
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
496014 E/A-Modul 4: operation transversal lock activation of function without operation mode B
function is not carried out
start engine and repeat operation
496100 E/A-Modul 4: operation unlocking rear axle function simultaneously ON and OFF B
function is not carried out
do not simultaneously activate contrasting function keys
496112 E/A-Modul 4: operation unlocking rear axle unauthorised switching off of function B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)
496114 E/A-Modul 4: operation unlocking rear axle activation of function without operation mode B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)
070645 264
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
496160 E/A-Modul 4: operation unlocking rear axle undefined condition: simultaneously locked and unlocked B
function is not carried out
check unlocking condition, Check locking limit switch and unlocking limit switch
496200 E/A-Modul 4: operation steering rear axle function simultaneously ON and OFF B
function is not carried out
do not simultaneously activate contrasting function keys
496214 E/A-Modul 4: operation steering rear axle activation of function without operation mode B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)
496440 E/A-Modul 4: operation supports simultaneous UP and DOWN operation of support control unit B
function is not carried out
actuate UP key or DOWN key of the respective support operating unit, start test program support service unit
496441 E/A-Modul 4: operation supports simultaneous IN and OUT operation of support control unit B
function is not carried out
actuate OFF key or ON key of the respective support operating unit, start test program support operating unit
496442 E/A-Modul 4: operation supports simultaneous UP and DOWN operation on upper-carriage monitor B
function is not carried out
actuate UP key or DOWN key of the respective support operating unit, start test program support service unit
496443 E/A-Modul 4: operation supports simultaneous IN and OUT operation on upper-carriage monitor B
function is not carried out
actuate OFF key or ON key of the respective support operating unit, start test program support operating unit
070645 265
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
496444 E/A-Modul 4: operation supports simultaneous left and right operation of support control unit B
function is not carried out
activate support from only one operating position or start test program support operating unit
496445 E/A-Modul 4: operation supports simultaneous operation of support control unit and upper-carriage B
function is not carried out
activate support from only one operating position or start test program support operating unit
496446 E/A-Modul 4: operation supports simultaneous operation of support control unit and upper-carriage B
function is not carried out
activate support from only one operating position or start test program support operating unit
496447 E/A-Modul 4: operation supports operation of support control unit with travel direction D engaged B
function is not carried out
switch transmission to neutral (N)
496448 E/A-Modul 4: operation supports operation of support control unit with travel direction R engaged B
function is not carried out
switch transmission to neutral (N)
496449 E/A-Modul 4: operation supports op. of upper-carriage monitor with travel direction D engaged B
function is not carried out
switch transmission to neutral (N)
499890 E/A-Modul 4: operation diagnosis system test program not executable as engine is not OFF B
function is not carried out
shut down engine
499892 E/A-Modul 4: operation diagnosis system test program not executable as not in under-carriage op. mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode
070645 266
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
502002 ZE 5: system error OS-TMS initialising error test total in EPROM/FLASH erroneous E 2
entry of error in error memory, all crane movements will be stopped
replace ZE
561002 E/A-Modul 5: system error OS-C167 initialising error test total in EPROM/FLASH erroneous E 2
error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul
070645 267
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
561088 E/A-Modul 5: system error OS-C167 Configuration does not match software condition E 1
Error output, possible error functions of module
Carry out EAM-download from LICCON
572052 E/A-Modul 5: input/output DEA0 output open, to low load, short circuit to supply voltage X653:17 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
572053 E/A-Modul 5: input/output DEA0 transistor current supply insufficient or missing X653:17 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
070645 268
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
572055 E/A-Modul 5: input/output DEA0 excessive temperature, short circuit to ground or overload X653:17 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
572152 E/A-Modul 5: input/output DEA1 output open, to low load, short circuit to supply voltage X653:15 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
572153 E/A-Modul 5: input/output DEA1 transistor current supply insufficient or missing X653:15 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
572155 E/A-Modul 5: input/output DEA1 excessive temperature, short circuit to ground or overload X653:15 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
572252 E/A-Modul 5: input/output DEA2 output open, to low load, short circuit to supply voltage X653:13 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
572253 E/A-Modul 5: input/output DEA2 transistor current supply insufficient or missing X653:13 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
572255 E/A-Modul 5: input/output DEA2 excessive temperature, short circuit to ground or overload X653:13 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
070645 269
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
572352 E/A-Modul 5: input/output DEA3 output open, to low load, short circuit to supply voltage X653:11 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
572353 E/A-Modul 5: input/output DEA3 transistor current supply insufficient or missing X653:11 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
572355 E/A-Modul 5: input/output DEA3 excessive temperature, short circuit to ground or overload X653:11 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
572452 E/A-Modul 5: input/output DEA4 output open, to low load, short circuit to supply voltage X653:9 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
572453 E/A-Modul 5: input/output DEA4 transistor current supply insufficient or missing X653:9 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
572455 E/A-Modul 5: input/output DEA4 excessive temperature, short circuit to ground or overload X653:9 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
572552 E/A-Modul 5: input/output DEA5 output open, to low load, short circuit to supply voltage X653:7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
572553 E/A-Modul 5: input/output DEA5 transistor current supply insufficient or missing X653:7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
070645 270
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
572555 E/A-Modul 5: input/output DEA5 excessive temperature, short circuit to ground or overload X653:7 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
572652 E/A-Modul 5: input/output DEA6 output open, to low load, short circuit to supply voltage X653:5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
572653 E/A-Modul 5: input/output DEA6 transistor current supply insufficient or missing X653:5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
572655 E/A-Modul 5: input/output DEA6 excessive temperature, short circuit to ground or overload X653:5 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
572752 E/A-Modul 5: input/output DEA7 output open, to low load, short circuit to supply voltage X653:3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
572753 E/A-Modul 5: input/output DEA7 transistor current supply insufficient or missing X653:3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
572755 E/A-Modul 5: input/output DEA7 excessive temperature, short circuit to ground or overload X653:3 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
070645 271
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
573482 E/A-Modul 5: voltage input E4 short circuit to ground, open line, constant current 10 mA incorrect X652:9 E 1
gear oil temperature warning light flashing on the display unit
check input signal on the E/A-Modul or sensor
573483 E/A-Modul 5: voltage input E4 short circuit to supply voltage, open line, lack of voltage X652:9 E 1
gear oil temperature warning light flashing on the display unit
check input signal on the E/A-Modul or sensor
579052 E/A-Modul 5: output A0 output open, to low load, short circuit to supply voltage X653:18 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
579055 E/A-Modul 5: output A0 excessive temperature, short circuit to ground or overload X653:18 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
579152 E/A-Modul 5: output A1 output open, to low load, short circuit to supply voltage X653:16 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
579155 E/A-Modul 5: output A1 excessive temperature, short circuit to ground or overload X653:16 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
070645 272
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
579250 E/A-Modul 5: bridge output A2 short circuit to ground, junction not supplied X653:14 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul
579251 E/A-Modul 5: bridge output A2 short circuit to supply voltage, excessive temperature X653:14 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul
579252 E/A-Modul 5: bridge output A2 output open, to low load, short circuit to supply voltage X653:14 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
579253 E/A-Modul 5: bridge output A2 transistor current supply insufficient or missing X653:14 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
579255 E/A-Modul 5: bridge output A2 excessive temperature, short circuit to ground or overload X653:14 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
579350 E/A-Modul 5: bridge output A3 short circuit to ground, junction not supplied X653:12 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul
579351 E/A-Modul 5: bridge output A3 short circuit to supply voltage, excessive temperature X653:12 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul
579352 E/A-Modul 5: bridge output A3 output open, to low load, short circuit to supply voltage X653:12 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
579353 E/A-Modul 5: bridge output A3 transistor current supply insufficient or missing X653:12 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
070645 273
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
579355 E/A-Modul 5: bridge output A3 excessive temperature, short circuit to ground or overload X653:12 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
584150 E/A-Modul 5: LSB-B participant address 1 reports an incorrect sensor type X653:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
584151 E/A-Modul 5: LSB-B participant address 1 was not configured for the block transfer X653:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
584153 E/A-Modul 5: LSB-B participant address 1 no longer reports or withdrawn during running period X653:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
584154 E/A-Modul 5: LSB-B participant address 1 Features other settings (parameters) as pre-entered set values X653:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
584164 E/A-Modul 5: LSB-B participant address 1 reports tolerable error in self-test X653:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
070645 274
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
584165 E/A-Modul 5: LSB-B participant address 1 reports intolerable error in self-test X653:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
584166 E/A-Modul 5: LSB-B participant address 1 with software version, that is no longer compatible X653:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
584250 E/A-Modul 5: LSB-B participant address 2 reports an incorrect sensor type X653:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
584251 E/A-Modul 5: LSB-B participant address 2 was not configured for the block transfer X653:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
584253 E/A-Modul 5: LSB-B participant address 2 no longer reports or withdrawn during running period X653:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
584254 E/A-Modul 5: LSB-B participant address 2 Features other settings (parameters) as pre-entered set values X653:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
070645 275
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
584264 E/A-Modul 5: LSB-B participant address 2 reports tolerable error in self-test X653:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
584265 E/A-Modul 5: LSB-B participant address 2 reports intolerable error in self-test X653:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
584266 E/A-Modul 5: LSB-B participant address 2 with software version, that is no longer compatible X653:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
584350 E/A-Modul 5: LSB-B participant address 3 reports an incorrect sensor type X653:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
584351 E/A-Modul 5: LSB-B participant address 3 was not configured for the block transfer X653:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
584353 E/A-Modul 5: LSB-B participant address 3 no longer reports or withdrawn during running period X653:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
070645 276
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
584354 E/A-Modul 5: LSB-B participant address 3 Features other settings (parameters) as pre-entered set values X653:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
584364 E/A-Modul 5: LSB-B participant address 3 reports tolerable error in self-test X653:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
584365 E/A-Modul 5: LSB-B participant address 3 reports intolerable error in self-test X653:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
584366 E/A-Modul 5: LSB-B participant address 3 with software version, that is no longer compatible X653:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
584450 E/A-Modul 5: LSB-B participant address 4 reports an incorrect sensor type X653:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
584451 E/A-Modul 5: LSB-B participant address 4 was not configured for the block transfer X653:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
070645 277
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
584453 E/A-Modul 5: LSB-B participant address 4 no longer reports or withdrawn during running period X653:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
584454 E/A-Modul 5: LSB-B participant address 4 Features other settings (parameters) as pre-entered set values X653:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
584464 E/A-Modul 5: LSB-B participant address 4 reports tolerable error in self-test X653:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
584465 E/A-Modul 5: LSB-B participant address 4 reports intolerable error in self-test X653:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
584466 E/A-Modul 5: LSB-B participant address 4 with software version, that is no longer compatible X653:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
584550 E/A-Modul 5: LSB-B participant address 5 reports an incorrect sensor type X653:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
070645 278
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
584551 E/A-Modul 5: LSB-B participant address 5 was not configured for the block transfer X653:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
584553 E/A-Modul 5: LSB-B participant address 5 no longer reports or withdrawn during running period X653:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
584554 E/A-Modul 5: LSB-B participant address 5 Features other settings (parameters) as pre-entered set values X653:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
584564 E/A-Modul 5: LSB-B participant address 5 reports tolerable error in self-test X653:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
584565 E/A-Modul 5: LSB-B participant address 5 reports intolerable error in self-test X653:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
584566 E/A-Modul 5: LSB-B participant address 5 with software version, that is no longer compatible X653:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 279
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
584650 E/A-Modul 5: LSB-B participant address 6 reports an incorrect sensor type X653:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
584651 E/A-Modul 5: LSB-B participant address 6 was not configured for the block transfer X653:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
584653 E/A-Modul 5: LSB-B participant address 6 no longer reports or withdrawn during running period X653:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
584654 E/A-Modul 5: LSB-B participant address 6 Features other settings (parameters) as pre-entered set values X653:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
584664 E/A-Modul 5: LSB-B participant address 6 reports tolerable error in self-test X653:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
584665 E/A-Modul 5: LSB-B participant address 6 reports intolerable error in self-test X653:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
584666 E/A-Modul 5: LSB-B participant address 6 with software version, that is no longer compatible X653:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
587252 E/A-Modul 5: Control data transfer LSB-B has recognised Bus collisions, communication interrupted X653:4/6 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor
587255 E/A-Modul 5: Control data transfer LSB-B Bus connection faulty/defect, short circuit to supply voltage X653:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
070645 280
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
587256 E/A-Modul 5: Control data transfer LSB-B Bus connection faulty/defect, no supply/short circuit to earth X653:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
587257 E/A-Modul 5: Control data transfer LSB-B has recognised network re-set (data transfer starts again) X653:4/6 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part
587258 E/A-Modul 5: Control data transfer LSB-B recognised participant with incorrect baud rate in bus X653:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors
587259 E/A-Modul 5: Control data transfer LSB-B recognised communication breakdown in bus X653:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network
587260 E/A-Modul 5: Control data transfer LSB-B driver error: no order to carry out X653:4/6 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software
587261 E/A-Modul 5: Control data transfer LSB-B driver error: undefined message appears X653:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination
587262 E/A-Modul 5: Control data transfer LSB-B Driver error: Initialization error X653:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination
587530 E/A-Modul 5: CAN-participant engine Data transfer subscriber transfer cycle exceeded X655:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant
587531 E/A-Modul 5: CAN-participant engine Data transfer faulty/missing, max. cycle time exceeded X655:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
587630 E/A-Modul 5: CAN-participant gear Data transfer subscriber transfer cycle exceeded X655:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul
070645 281
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
587631 E/A-Modul 5: CAN-participant gear Data transfer faulty/missing, max. cycle time exceeded X655:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
587730 E/A-Modul 5: CAN-participant ABV (ABS/ASR) Data transfer subscriber transfer cycle exceeded X655:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul
587731 E/A-Modul 5: CAN-participant ABV (ABS/ASR) Data transfer faulty/missing, max. cycle time exceeded X655:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
587930 E/A-Modul 5: CAN-participant retarder Data transfer subscriber transfer cycle exceeded X655:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul
587931 E/A-Modul 5: CAN-participant retarder Data transfer faulty/missing, max. cycle time exceeded X655:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
588030 E/A-Modul 5: CAN-user converter clutch unit CCU Data transfer subscriber transfer cycle exceeded X655:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul
588031 E/A-Modul 5: CAN-user converter clutch unit CCU Data transfer faulty/missing, max. cycle time exceeded X655:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
588530 E/A-Modul 5: CAN-participant E/A-Modul 1 Data transfer subscriber transfer cycle exceeded X655:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant
588531 E/A-Modul 5: CAN-participant E/A-Modul 1 Data transfer faulty/missing, max. cycle time exceeded X655:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
588930 E/A-Modul 5: CAN-participant E/A-Modul 5 Data transfer subscriber transfer cycle exceeded X655:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant
070645 282
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
588931 E/A-Modul 5: CAN-participant E/A-Modul 5 Data transfer faulty/missing, max. cycle time exceeded X655:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
589900 E/A-Modul 5: Control data transfer CAN internal error at Register-check Controller X655:5/6 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul
589901 E/A-Modul 5: Control data transfer CAN internal error at RAM-check Controller X655:5/6 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul
589902 E/A-Modul 5: Control data transfer CAN Configuration error Software X655:5/6 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul, check Software (test system ZE)
589903 E/A-Modul 5: Control data transfer CAN Transfer interrupted after continuous error X655:5/6 E 1
CAN-Transmission will be aborted
check bus lines/neutral point, replace neutral point or E/A-Modul
589910 E/A-Modul 5: Control data transfer CAN short-term error in bus connection X655:5/6 E 0
re-attachment of Modul to bus transmission
check bus lines/neutral point, unplug individual bus participant and check if error has been eliminated
589911 E/A-Modul 5: Control data transfer CAN permanent error bus connection X655:5/6 E 1
cyclic re-attachment of Modul to bus transmission
check bus lines/neutral point, unplug individual bus participant and check if error has been eliminated
589920 E/A-Modul 5: Control data transfer CAN active participant not responding X655:5/6 E 0
parameterised substitute values for receiver signals will be used
check error report for missing participant(s), test system ZE
589921 E/A-Modul 5: Control data transfer CAN No active subscriber responding X655:5/6 E 1
parameterised substitute values for receiver signals will be used
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul
589950 E/A-Modul 5: Control data transfer CAN erroneous command test system X655:5/6 E 1
no reaction to unknown test system control command in CAN-System Software
check Software (test system)
070645 283
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
592001 E/A-Modul 5: control engine long-term disruption E/A-Modul <-> engine control E 1
engine control and E/A-Modul at emergency speed
engine control and E/A-Modul, check CAN-bus-connections
592005 E/A-Modul 5: control engine condition erroneous: CAN-signal engine ON <-> load ctrl. D+ OFF E 1
identification engine ON/OFF possibly erronous
check alternator line connection to display unit, check alternator signal
592006 E/A-Modul 5: control engine condition erroneous: CAN-signal engine OFF <-> load ctrl. D+ ON E 1
identification engine ON/OFF possibly erronous
check alternator line connection to display unit, check alternator signal
592036 E/A-Modul 5: control engine Travel speed Tachograph <> Gear output RPM not plausible E 1
Tempomat/Temposet-function blocked, engine will be limited in the torque output
Tacograph connection <>E/A-Modul, signals to inputs from E/A-Modul, check gear speed; replace E/A-Modul Taco
592121 E/A-Modul 5: control transmission shift selector-specified gear range/travel direction erroneous E 1
travel switch signals will be switched off, emergency operation
check CAN-bus system, Check Software in E/A-Modules (test system)
592123 E/A-Modul 5: control transmission switch prevention ("do not shift"), retrieve gear error E 1
transmission control shift-selector primary controls neutral or prevents the selection of a travel direction D/R
check transmission, E/A-Modul 5, lines
592124 E/A-Modul 5: control transmission control device reports error ("check trans"), retrieve gear error E 1
error report will be reported through control device if diagnosis key is permanently actuated
activate diagnosis key permanently until system error transmission appears
070645 284
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
592957 E/A-Modul 5: control brakes/pneumatic system brake pressure switch 0.5 bar signal "op. brakes active" missing E 1
operation brake signal activated if circle 1+2 > 1,5 bar, stronger application of the brake necessary
check connection from brake pressure switch to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593160 E/A-Modul 5: instruments operators cab auxiliary brakes signal level 1 missing E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593161 E/A-Modul 5: instruments operators cab auxiliary brakes signal level 2 missing E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593162 E/A-Modul 5: instruments operators cab auxiliary brakes signal level 3 missing E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593165 E/A-Modul 5: instruments operators cab auxiliary brakes signal level 1 short to supply voltage E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593166 E/A-Modul 5: instruments operators cab auxiliary brakes signal level 2 short to supply voltage E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593167 E/A-Modul 5: instruments operators cab auxiliary brakes signal level 3 short to supply voltage E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593175 E/A-Modul 5: instruments operators cab Tempomat lever no signal or supply voltage missing E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593176 E/A-Modul 5: instruments operators cab Tempomat lever signal SET+ no signal or short to ground E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593177 E/A-Modul 5: instruments operators cab Tempomat lever signal SET- no signal or short to ground E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
070645 285
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
593178 E/A-Modul 5: instruments operators cab Tempomat lever signal OFF no signal or short to ground E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593179 E/A-Modul 5: instruments operators cab Tempomat lever signal QUIT short to supply voltage E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593180 E/A-Modul 5: instruments operators cab Tempomat lever signal TEMPOSET short to supply voltage E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593181 E/A-Modul 5: instruments operators cab Tempomat lever signal TEMPOMAT SET+ without returning (QUIT) E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593182 E/A-Modul 5: instruments operators cab Tempomat lever signal TEMPOMAT SET- without returning (QUIT) E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593183 E/A-Modul 5: instruments operators cab Tempomat lever signal OFF without returning (QUIT) E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593184 E/A-Modul 5: instruments operators cab Tempomat lever signals SET+, SET-, OFF erroneous combination E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
070645 286
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
595074 E/A-Modul 5: operation engine accelerator operators cab blocked in upper-carriage operation mode B
function is not carried out
595075 E/A-Modul 5: operation engine accelerator operators cab blocked in support operation mode B
function is not carried out
595076 E/A-Modul 5: operation engine accelerator op. cab blocked when auxiliary brake active or selected B
function is not carried out
595077 E/A-Modul 5: operation engine accelerator upper-carr. activated on malf. of GAS <-> E/A-Modul B
function is not carried out
595194 E/A-Modul 5: operation transmission selection of travel dir. prevented due to gear malf. "do not shift" B
function is not carried out
595195 E/A-Modul 5: operation transmission pre-selection not neutral after gear malfunction "do not shift" B
function is not carried out
596885 E/A-Modul 5: operation instruments operators cab Tempomat lever blocked in upper-carriage operation mode B
function is not carried out
596886 E/A-Modul 5: operation instruments operators cab Tempomat lever blocked in support operation mode B
function is not carried out
070645 287
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
661002 E/A-Modul 6: system error OS-C167 initialising error test total in EPROM/FLASH erroneous E 2
error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul
661088 E/A-Modul 6: system error OS-C167 Configuration does not match software condition E 1
Error output, possible error functions of module
Carry out EAM-download from LICCON
070645 288
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
672052 E/A-Modul 6: input/output DEA0 output open, to low load, short circuit to supply voltage X663:17 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
672053 E/A-Modul 6: input/output DEA0 transistor current supply insufficient or missing X663:17 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
672055 E/A-Modul 6: input/output DEA0 excessive temperature, short circuit to ground or overload X663:17 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
672152 E/A-Modul 6: input/output DEA1 output open, to low load, short circuit to supply voltage X663:15 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
672153 E/A-Modul 6: input/output DEA1 transistor current supply insufficient or missing X663:15 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
672155 E/A-Modul 6: input/output DEA1 excessive temperature, short circuit to ground or overload X663:15 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
070645 289
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
672252 E/A-Modul 6: input/output DEA2 output open, to low load, short circuit to supply voltage X663:13 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
672253 E/A-Modul 6: input/output DEA2 transistor current supply insufficient or missing X663:13 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
672255 E/A-Modul 6: input/output DEA2 excessive temperature, short circuit to ground or overload X663:13 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
672352 E/A-Modul 6: input/output DEA3 output open, to low load, short circuit to supply voltage X663:11 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
672353 E/A-Modul 6: input/output DEA3 transistor current supply insufficient or missing X663:11 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
672355 E/A-Modul 6: input/output DEA3 excessive temperature, short circuit to ground or overload X663:11 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
672452 E/A-Modul 6: input/output DEA4 output open, to low load, short circuit to supply voltage X663:9 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
672453 E/A-Modul 6: input/output DEA4 transistor current supply insufficient or missing X663:9 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
070645 290
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
672455 E/A-Modul 6: input/output DEA4 excessive temperature, short circuit to ground or overload X663:9 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
672552 E/A-Modul 6: input/output DEA5 output open, to low load, short circuit to supply voltage X663:7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
672553 E/A-Modul 6: input/output DEA5 transistor current supply insufficient or missing X663:7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
672555 E/A-Modul 6: input/output DEA5 excessive temperature, short circuit to ground or overload X663:7 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
672652 E/A-Modul 6: input/output DEA6 output open, to low load, short circuit to supply voltage X663:5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
672653 E/A-Modul 6: input/output DEA6 transistor current supply insufficient or missing X663:5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
672655 E/A-Modul 6: input/output DEA6 excessive temperature, short circuit to ground or overload X663:5 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
070645 291
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
672752 E/A-Modul 6: input/output DEA7 output open, to low load, short circuit to supply voltage X663:3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
672753 E/A-Modul 6: input/output DEA7 transistor current supply insufficient or missing X663:3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
672755 E/A-Modul 6: input/output DEA7 excessive temperature, short circuit to ground or overload X663:3 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
673782 E/A-Modul 6: voltage input E7 short circuit to ground, open line, constant current 10 mA incorrect X662:3 E 1
display Liccon:??? %
check input signal on the E/A-Modul or sensor
673783 E/A-Modul 6: voltage input E7 short circuit to supply voltage, open line, lack of voltage X662:3 E 1
display Liccon:??? %
check input signal on the E/A-Modul or sensor
679052 E/A-Modul 6: output A0 output open, to low load, short circuit to supply voltage X663:18 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
679055 E/A-Modul 6: output A0 excessive temperature, short circuit to ground or overload X663:18 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
070645 292
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
679152 E/A-Modul 6: output A1 output open, to low load, short circuit to supply voltage X663:16 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
679155 E/A-Modul 6: output A1 excessive temperature, short circuit to ground or overload X663:16 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
679250 E/A-Modul 6: bridge output A2 short circuit to ground, junction not supplied X663:14 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul
679251 E/A-Modul 6: bridge output A2 short circuit to supply voltage, excessive temperature X663:14 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul
679252 E/A-Modul 6: bridge output A2 output open, to low load, short circuit to supply voltage X663:14 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
679253 E/A-Modul 6: bridge output A2 transistor current supply insufficient or missing X663:14 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
679255 E/A-Modul 6: bridge output A2 excessive temperature, short circuit to ground or overload X663:14 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
070645 293
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
679350 E/A-Modul 6: bridge output A3 short circuit to ground, junction not supplied X663:12 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul
679351 E/A-Modul 6: bridge output A3 short circuit to supply voltage, excessive temperature X663:12 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul
679352 E/A-Modul 6: bridge output A3 output open, to low load, short circuit to supply voltage X663:12 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
679353 E/A-Modul 6: bridge output A3 transistor current supply insufficient or missing X663:12 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
679355 E/A-Modul 6: bridge output A3 excessive temperature, short circuit to ground or overload X663:12 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul
684150 E/A-Modul 6: LSB-B participant address 1 reports an incorrect sensor type X663:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
070645 294
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
684151 E/A-Modul 6: LSB-B participant address 1 was not configured for the block transfer X663:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
684153 E/A-Modul 6: LSB-B participant address 1 no longer reports or withdrawn during running period X663:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
684154 E/A-Modul 6: LSB-B participant address 1 Features other settings (parameters) as pre-entered set values X663:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
684164 E/A-Modul 6: LSB-B participant address 1 reports tolerable error in self-test X663:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
684165 E/A-Modul 6: LSB-B participant address 1 reports intolerable error in self-test X663:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
684166 E/A-Modul 6: LSB-B participant address 1 with software version, that is no longer compatible X663:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 295
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
684250 E/A-Modul 6: LSB-B participant address 2 reports an incorrect sensor type X663:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
684251 E/A-Modul 6: LSB-B participant address 2 was not configured for the block transfer X663:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
684253 E/A-Modul 6: LSB-B participant address 2 no longer reports or withdrawn during running period X663:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
684254 E/A-Modul 6: LSB-B participant address 2 Features other settings (parameters) as pre-entered set values X663:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
684264 E/A-Modul 6: LSB-B participant address 2 reports tolerable error in self-test X663:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
684265 E/A-Modul 6: LSB-B participant address 2 reports intolerable error in self-test X663:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
684266 E/A-Modul 6: LSB-B participant address 2 with software version, that is no longer compatible X663:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
070645 296
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
686150 E/A-Modul 6: LSB-B participant address 21 reports an incorrect sensor type X663:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
686151 E/A-Modul 6: LSB-B participant address 21 was not configured for the block transfer X663:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
686153 E/A-Modul 6: LSB-B participant address 21 no longer reports or withdrawn during running period X663:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
686154 E/A-Modul 6: LSB-B participant address 21 Features other settings (parameters) as pre-entered set values X663:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
686164 E/A-Modul 6: LSB-B participant address 21 reports tolerable error in self-test X663:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor
686165 E/A-Modul 6: LSB-B participant address 21 reports intolerable error in self-test X663:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
686166 E/A-Modul 6: LSB-B participant address 21 with software version, that is no longer compatible X663:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
687252 E/A-Modul 6: Control data transfer LSB-B has recognised Bus collisions, communication interrupted X663:4/6 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor
070645 297
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
687255 E/A-Modul 6: Control data transfer LSB-B Bus connection faulty/defect, short circuit to supply voltage X663:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
687256 E/A-Modul 6: Control data transfer LSB-B Bus connection faulty/defect, no supply/short circuit to earth X663:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
687257 E/A-Modul 6: Control data transfer LSB-B has recognised network re-set (data transfer starts again) X663:4/6 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part
687258 E/A-Modul 6: Control data transfer LSB-B recognised participant with incorrect baud rate in bus X663:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors
687259 E/A-Modul 6: Control data transfer LSB-B recognised communication breakdown in bus X663:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network
687260 E/A-Modul 6: Control data transfer LSB-B driver error: no order to carry out X663:4/6 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software
687261 E/A-Modul 6: Control data transfer LSB-B driver error: undefined message appears X663:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination
687262 E/A-Modul 6: Control data transfer LSB-B Driver error: Initialization error X663:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination
687530 E/A-Modul 6: CAN-participant engine Data transfer subscriber transfer cycle exceeded X665:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
Check CAN network, check faulty Bus user.
687531 E/A-Modul 6: CAN-participant engine Data transfer faulty/missing, max. cycle time exceeded X665:5/6 E 1
parameterised substitute values for receiver signals will be used
Check CAN network, check faulty Bus user.
070645 298
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
689030 E/A-Modul 6: CAN-participant E/A-Modul 6 Data transfer subscriber transfer cycle exceeded X665:5/6 E 0
CAN-Transmission will be aborted
Check CAN network, replace E/A-Modul
689031 E/A-Modul 6: CAN-participant E/A-Modul 6 Data transfer faulty/missing, max. cycle time exceeded X665:5/6 E 1
CAN-Information from participant has exceeded the defined cycle time
Check CAN network, check faulty Bus user.
689900 E/A-Modul 6: Control data transfer CAN internal error at Register-check Controller X665:5/6 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul
689901 E/A-Modul 6: Control data transfer CAN internal error at RAM-check Controller X665:5/6 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul
689902 E/A-Modul 6: Control data transfer CAN Configuration error Software X665:5/6 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul, check Software (test system ZE)
689903 E/A-Modul 6: Control data transfer CAN Transfer interrupted after continuous error X665:5/6 E 1
CAN-Transmission will be aborted
Check CAN network, replace E/A-Modul
689910 E/A-Modul 6: Control data transfer CAN short-term error in bus connection X665:5/6 E 0
re-attachment of Modul to bus transmission
Check CAN network, connect individual Bus users and check if error has been remedied
689911 E/A-Modul 6: Control data transfer CAN permanent error bus connection X665:5/6 E 1
cyclic re-attachment of Modul to bus transmission
Check CAN network, connect individual Bus users and check if error has been remedied
689920 E/A-Modul 6: Control data transfer CAN active participant not responding X665:5/6 E 0
parameterised substitute values for receiver signals will be used
check error report for missing participant(s), test system ZE
689921 E/A-Modul 6: Control data transfer CAN No active subscriber responding X665:5/6 E 1
parameterised substitute values for receiver signals will be used
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul
070645 299
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
689950 E/A-Modul 6: Control data transfer CAN erroneous command test system X665:5/6 E 1
no reaction to unknown test system control command in CAN-System Software
check Software (test system)
692001 E/A-Modul 6: control engine long-term disruption E/A-Modul <-> engine control E 1
with permanent CAN-disruption engine control goes to emergency speed, ctrl. through E/A-Modul also emergency speed
After re-establishment of the CAN-communication the motor electronics remain in emergency speed --> ignition on/off
692005 E/A-Modul 6: control engine condition erroneous: CAN-signal engine ON <-> load ctrl. D+ OFF E 1
692006 E/A-Modul 6: control engine condition erroneous: CAN-signal engine OFF <-> load ctrl. D+ ON E 1
696953 E/A-Modul 6: operation instruments crane operators cab Engine-Stop UC actuated/sticking/short circuit to supply upon start B
Key Engine-Stop without function
Release key; key sticks or signal line/entry has short-circuit to supply voltage
701000 Power supply unit: Memory card faulty, transmission error, addressing error E 2
Shut-down
Replace slide-in card
702100 Power supply unit: RAM-memory faulty, transmission error, addressing error E 2
Shut-down
Replace slide-in card, check connections ZE/bus motherboard/power supply unit
702101 Power supply unit: RAM-memory faulty, transmission error, addressing error E 2
Shut-down
Replace slide-in card, check connections ZE/bus motherboard/power supply unit
702200 Power supply unit: FLASH- memory faulty, transmission error, addressing error E 2
Shut-down
Replace slide-in card, check connections ZE/bus motherboard/power supply unit
070645 300
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
702300 Power supply unit: EEPROM- memory faulty, transmission error, addressing error E 2
Shut-down
Replace slide-in card, check connections ZE/bus motherboard/power supply unit
702400 Power supply unit: Globalbus-/QW-transmission faulty, transmission error, addressing error E 2
Shut-down
Replace slide-in card, check connections ZE/bus motherboard/power supply unit
702401 Power supply unit: Globalbus-/QW-transmission faulty, transmission error, addressing error E 2
Shut-down
Check ZE/bus motherboard/power supply unit connections
702500 Power supply unit: FLASH- memory, - module faulty, transmission error, addressing error E 2
Shut-down
Replace slide-in card, check connections ZE/bus motherboard/power supply unit
703001 Power supply unit: FPGA faulty, transmission error, addressing error E 2
Shut-down
Replace slide-in card, check connections ZE/bus motherboard/power supply unit
709003 Power supply unit: internal error ADC-conversion faulty, processor error, time exceeded E 2
Shut-down
Replace power supply unit
709010 Power supply unit: internal error Signal to Done-Pin incorrect (0) E 2
Shut-down
Check ZE/bus motherboard/power supply unit
709011 Power supply unit: internal error Signal to Done-Pin incorrect (1) E 2
Shut-down
Check ZE/bus motherboard/power supply unit
070645 301
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
709020 Power supply unit: internal error SCI transmission error, time exceeded (overrun) E 2
Shut-down
Replace power supply unit
709030 Power supply unit: internal error LCA-design time exceeded (ZE 0 faulty/missing) E 2
Shut-down
Check ZE/bus motherboard/power supply unit
709050 Power supply unit: internal error Bus controller addressing/time exceeded/data transmission (P1) E 2
Shut-down
Replace power supply unit
709060 Power supply unit: internal error Signal error "Control on" different 0, relay contact sticking E 2
Shut-down
Check plug/connections/relay
709080 Power supply unit: internal error Initialising error excess/lack of voltage E 2
Shut-down
Check voltage supply, replace power supply unit
709081 Power supply unit: internal error Lack of voltage (P0 = channel, P1 = value) E 2
Shut-down
Check voltage supply, replace power supply unit
709082 Power supply unit: internal error Excess voltage (P0 = channel, P1 = value) E 2
Shut-down
Check voltage supply, replace power supply unit
709099 Power supply unit: internal error Power supply unit off, power supply unit shut-down (note parameter) E 2
Shut-down
Replace power supply unit
070645 302
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
810162 ABV: CAN-bus system Speed signal Tachograph to CAN faulty/missing/implausible X94:1/2/3 E 1
ABV function not restricted
check CAN-network, ABV-control device, speed signal C3, E/A-Modul 5
810168 ABV: CAN-bus system CAN-communication engine erroneous/missing (ID 592) X94:1/2/3 E 0
ABV function not restricted
check CAN-network, check/replace ABV-control device
811001 ABV: control device error or power supply Kl.15/30 excess voltage X94:7/9 E 1
ABS: inactive
check net supply control device
811002 ABV: control device error or power supply Kl.15/30 voltage below required value X94:7/9 E 1
ABS: inactive
check net supply control device
811010 ABV: control device error or power supply Kl.15/30 defect X94:7/9 E 1
ABS: inactive, ASR: inactive
replace control device
811012 ABV: control device error or power supply Kl.15/30 incorrect parameters X94:7/9 E 1
ABS: inactive, ASR: inactive
replace control device
070645 303
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
811029 ABV: control device error or power supply Kl.15/30 monitor switch time for solenoid valve actuated X94:7/9 E 0
ABS: inactive, ASR: inactive
check solenoid valve, control device
811094 ABV: control device error or power supply Kl.15/30 Wheel speeds/tyre dimensions implausible, incorrect parameterisation X94:7/9 E 1
ABS: wheel not regulated, ASR: inactive
check tires, magnet wheels, sensors
811102 ABV: control device error or power supply Kl.15/30 voltage below required value X94:7/9 E 1
ABS: inactive
check net supply control device
811103 ABV: control device error or power supply Kl.15/30 interruption X94:7/9 E 1
ABS: inactive
check net supply control device
811202 ABV: control device error or power supply Kl.15/30 voltage below required value X94:7/9 E 1
ABS: inactive
check net supply control device
811203 ABV: control device error or power supply Kl.15/30 interruption X94:7/9 E 1
ABS: inactive
check net supply control device
811602 ABV: control device error, power supply Kl.31 voltage below required value X94:10/12 E 1
ABS: inactive
check net supply control device
811609 ABV: control device error, power supply Kl.31 interruption X94:10/12 E 1
ABS: inactive
check net supply control device
811702 ABV: control device error, power supply Kl.31 voltage below required value X94:10/12 E 1
ABS: inactive
check net supply control device
811709 ABV: control device error, power supply Kl.31 interruption X94:10/12 E 1
ABS: inactive
check net supply control device
070645 304
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
813021 ABV: ABS-solenoid valve front axle right short circuit to ground X96:7/8/9 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813022 ABV: ABS-solenoid valve front axle right short circuit to supply voltage X96:7/8/9 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
070645 305
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
813027 ABV: ABS-solenoid valve front axle right short circuit to ground X96:7/8/9 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813028 ABV: ABS-solenoid valve front axle right short circuit to supply voltage X96:7/8/9 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813030 ABV: ABS-solenoid valve front axle right external control X96:7/8/9 E 2
ABS: front/rear diagonal and differential brakes inactive
check cabling, valve (ohm resistance), control device
813121 ABV: ABS-solenoid valve front axle left short circuit to ground X95:1/2/3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813122 ABV: ABS-solenoid valve front axle left short circuit to supply voltage X95:1/2/3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813127 ABV: ABS-solenoid valve front axle left short circuit to ground X95:1/2/3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
070645 306
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
813128 ABV: ABS-solenoid valve front axle left short circuit to supply voltage X95:1/2/3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813130 ABV: ABS-solenoid valve front axle left external control X95:1/2/3 E 2
ABS: front/rear diagonal and differential brakes inactive
check cabling, valve (ohm resistance), control device
813221 ABV: ABS-solenoid valve rear axle right short circuit to ground X97:10/11/12 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813222 ABV: ABS-solenoid valve rear axle right short circuit to supply voltage X97:10/11/12 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813227 ABV: ABS-solenoid valve rear axle right short circuit to ground X97:10/11/12 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813228 ABV: ABS-solenoid valve rear axle right short circuit to supply voltage X97:10/11/12 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813230 ABV: ABS-solenoid valve rear axle right external control X97:10/11/12 E 2
ABS: front/rear diagonal and differential brakes inactive
check cabling, valve (ohm resistance), control device
070645 307
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
813321 ABV: ABS-solenoid valve rear axle left short circuit to ground X97:1/2/3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813322 ABV: ABS-solenoid valve rear axle left short circuit to supply voltage X97:1/2/3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813327 ABV: ABS-solenoid valve rear axle left short circuit to ground X97:1/2/3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813328 ABV: ABS-solenoid valve rear axle left short circuit to supply voltage X97:1/2/3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813330 ABV: ABS-solenoid valve rear axle left external control X97:1/2/3 E 2
ABS: front/rear diagonal and differential brakes inactive
check cabling, valve (ohm resistance), control device
813604 ABV: valve front axle right and rear axle left short circuit to ground X96/X97 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813605 ABV: valve front axle right and rear axle left short circuit to supply voltage X96/X97 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
070645 308
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
813704 ABV: valve front axle left and rear axle right short circuit to ground X96/X98 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813705 ABV: valve front axle left and rear axle right short circuit to supply voltage X96/X98 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
814041 ABV: speed sensor front axle right short circuit to ground X96:4/5 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
814042 ABV: speed sensor front axle right short circuit to supply voltage X96:4/5 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
814044 ABV: speed sensor front axle right winding short X96:4/5 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
070645 309
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
814045 ABV: speed sensor front axle right magnet wheel defect X96:4/5 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel
814046 ABV: speed sensor front axle right sensor vibration X96:4/5 E 0
ABS: partly inactive, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel
814047 ABV: speed sensor front axle right shimmed magnet wheel X96:4/5 E 0
814048 ABV: speed sensor front axle right Air gap, clearance sensor<>magnet wheel too large X96:4/5 E 1
ABS: wheel not regulated, ASR: inactive
check play in wheel bearing, sensor voltage, ohm resistance of cabling; push sensor on magnet wheel
814141 ABV: speed sensor front axle left short circuit to ground X95:4/5 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
814142 ABV: speed sensor front axle left short circuit to supply voltage X95:4/5 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
814144 ABV: speed sensor front axle left winding short X95:4/5 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
814145 ABV: speed sensor front axle left magnet wheel defect X95:4/5 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel
814146 ABV: speed sensor front axle left sensor vibration X95:4/5 E 0
ABS: partly inactive, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel
070645 310
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
814147 ABV: speed sensor front axle left shimmed magnet wheel X95:4/5 E 0
814148 ABV: speed sensor front axle left Air gap, clearance sensor<>magnet wheel too large X95:4/5 E 1
ABS: wheel not regulated, ASR: inactive
check play in wheel bearing, sensor voltage, ohm resistance of cabling; push sensor on magnet wheel
814241 ABV: speed sensor rear axle right short circuit to ground X97:8/9 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
814242 ABV: speed sensor rear axle right short circuit to supply voltage X97:8/9 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
814244 ABV: speed sensor rear axle right winding short X97:8/9 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
814245 ABV: speed sensor rear axle right magnet wheel defect X97:8/9 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel
814246 ABV: speed sensor rear axle right sensor vibration X97:8/9 E 0
ABS: partly inactive, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel
814247 ABV: speed sensor rear axle right shimmed magnet wheel X97:8/9 E 0
814248 ABV: speed sensor rear axle right Air gap, clearance sensor<>magnet wheel too large X97:8/9 E 1
ABS: wheel not regulated, ASR: inactive
check play in wheel bearing, sensor voltage, ohm resistance of cabling; push sensor on magnet wheel
070645 311
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
814341 ABV: speed sensor rear axle left short circuit to ground X97:5/6 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
814342 ABV: speed sensor rear axle left short circuit to supply voltage X97:5/6 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
814344 ABV: speed sensor rear axle left winding short X97:5/6 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
814345 ABV: speed sensor rear axle left magnet wheel defect X97:5/6 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel
814346 ABV: speed sensor rear axle left sensor vibration X97:5/6 E 0
ABS: partly inactive, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel
814347 ABV: speed sensor rear axle left shimmed magnet wheel X97:5/6 E 0
814348 ABV: speed sensor rear axle left Air gap, clearance sensor<>magnet wheel too large X97:5/6 E 1
ABS: wheel not regulated, ASR: inactive
check play in wheel bearing, sensor voltage, ohm resistance of cabling; push sensor on magnet wheel
821111 retarder: Output AD1 - re-circulation valve short circuit to ground X46:1 E 1
ECU no longer selects recirculation valve, response time becomes longer
RESET - otherwise check cabling between ECU and recirculation valve, check recirculation valve (internal resistance)
821112 retarder: Output AD1 - re-circulation valve short circuit to supply voltage X46:1 E 1
ECU no longer selects recirculation valve, response time becomes longer
INT OFF/ON - otherwise check cabling between ECU and recirculation valve
070645 312
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
821911 retarder: Output AIP- proportional-flow valve short circuit to ground X46:4 E 1
ECU switches off the intarder; Intarder no longer available
RESET - otherwise check cabling between ECU and proportional-flow valve, check pr.-flow valve (int. resistance)
821912 retarder: Output AIP- proportional-flow valve short circuit to supply voltage X46:4 E 1
ECU switches off the intarder; Intarder no longer available
RESET - otherwise check cabling between ECU and proportional-flow valve
822111 retarder: Output ADM1 - Dimensions proportional-flow valve short circuit to ground X46:3 E 1
ECU switches off the intarder; Intarder no longer available
RESET - otherwise check cabling between ECU and proportional-flow valve
822112 retarder: Output ADM1 - Dimensions proportional-flow valve short circuit to supply voltage X46:3 E 1
ECU switches off the intarder; Intarder no longer available
RESET - otherwise check cabling between ECU and proportional-flow valve, check pr.-flow valve (int. resistance)
822316 retarder: Amperemeter channel proportional-flow valve Malfunction limit fallen short of X46:3/4 E 1
ECU switches off the intarder; Intarder no longer available
RESET - otherwise replace ECU
822317 retarder: Amperemeter channel proportional-flow valve Malfunction limit exceeded X46:3/4 E 1
ECU switches off the intarder; Intarder no longer available
RESET - otherwise replace ECU
823211 retarder: Input ER1 - temperature sensor short circuit to ground X46:9 E 1
ECU limits the braking action to 100 kW
INT OFF/ON - otherwise check cabling between ECU and temperature sensor, check temperature sensor (resistance)
070645 313
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
823318 retarder: Inputs ED1..ED5 - brake stage switch Check sum / signal(s) implausible X46:15/16/17/42 E 1
ECU reduces the set braking level under certain circumstances /43
INT OFF/ON - otherwise check cabling between ECU and brake level switch, check brake level switch
824319 retarder: CAN transmission malfunction Data transfer faulty/missing, signal error X46:22/49/21/48 E 1
no reaction
RESET - otherwise check CAN-Bus line, check shut-down resistance
824415 retarder: CAN-Bus Data transfer faulty/missing, max. cycle time exceeded X46:22/49/21/48 E 1
ECU switches off the intarder; Intarder no longer available
RESET - otherwise check CAN-Bus line
824615 retarder: CAN-Bus data transfer Data transfer faulty/missing, max. cycle time exceeded X46:22/49/21/48 E 1
no reaction
RESET - otherwise check CAN-Bus line, check shut-down resistance
825819 retarder: CAN-data transfer ABS/ASR (ID 512) Data transfer faulty/missing, signal error X46:22/49 E 1
ECU switches off the intarder; Intarder no longer available
INT OFF/ON - otherwise check ABS-ECU, check CAN-Bus line, check shut-down resistance
825919 retarder: CAN-data transfer engine (ID 592) Data transfer faulty/missing, signal error X46:22/49 E 1
ECU limits the braking action to 350 kW
INT OFF/ON - otherwise check FMR-ECU, check CAN-Bus line, check shut-down resistance
826119 retarder: CAN-data transfer engine (ID 593) Data transfer faulty/missing, signal error X46:22/49 E 1
ECU limits the braking action to 350 kW
INT OFF/ON - otherwise check FMR-ECU, check CAN-Bus line, check shut-down resistance
826219 retarder: CAN-data transfer gears (ID 556) Data transfer faulty/missing, signal error X46:22/49 E 1
ECU limits the power to 250 mA, the automatic brake (Bremsomat) is not available
INT OFF/ON - otherwise check TCU-ECU, check CAN-Bus line, check shut-down resistance
070645 314
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
827216 retarder: Supply VPI1/VPI2 Kl.15 Malfunction limit fallen short of X46:53/31 E 1
ECU switches off the intarder; Intarder no longer available
RESET - otherwise check mains voltage (battery, dynamo)
828218 retarder: Operating hours counter Check sum / signal(s) implausible X46 E 0
ECU resets the operating hour counter back to 0
replace ECU
828415 retarder: System error Data transfer faulty/missing, max. cycle time exceeded X46 E 1
ECU switches off the intarder; Intarder no longer available
replace ECU
843300 heating, air cond.: Aux. heater chassis steering device error E 1
843302 heating, air cond.: Aux. heater chassis repeated glow interruption E 1
843303 heating, air cond.: Aux. heater chassis lack of voltage/excess voltage E 1
843304 heating, air cond.: Aux. heater chassis premature glow identification E 1
070645 315
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
843305 heating, air cond.: Aux. heater chassis glow probe interruption/short circuit E 1
843306 heating, air cond.: Aux. heater chassis temperature probe interruption/short circuit E 1
843307 heating, air cond.: Aux. heater chassis metering pump/solenoid valve interruption/short circuit E 1
843308 heating, air cond.: Aux. heater chassis blower motor interruption/short circuit/erroneous speed E 1
843309 heating, air cond.: Aux. heater chassis glow pin interruption/short circuit E 1
843311 heating, air cond.: Aux. heater chassis water pump interruption/short circuit E 1
843312 heating, air cond.: Aux. heater chassis set value sensor interruption/short circuit E 1
859912 gear CLBT 755: ECU error report oil pressure or oil level insufficient J E 1
report
check oil level/oil pressure and sensor
859913 gear CLBT 755: ECU error report supply voltage to ECU insufficient J1A:2A/3A E 1
report
check 12V-supply through voltage transformer, supply lines
070645 316
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
859914 gear CLBT 755: ECU error report pressure switch for signal "forwards" defective/missing J1B:3P E 1
report
check sensor, lines
859915 gear CLBT 755: ECU error report pressure switch for signal "backwards" defective/missing J1B:1R E 1
report
check sensor, lines
859921 gear CLBT 755: ECU error report load signal TPS accelerator defective/missing J1B:1P/2P E 1
only still full- or partial load switches will be carried out, switch quality worse
check accelerator, CAN, E/A-Modul 5, ECU, lines
859922 gear CLBT 755: ECU error report output speed sensor defective/missing J1A:1L/1M E 1
report
check sensor, lines, ECU, installation sensor
859923 gear CLBT 755: ECU error report shift selector sig. (primary) from E/A-Modul 5 defective/missing J1A:1F/1H/2F/1G E 1
emergency program, perhaps gear pre-selection not possible
check ECU, E/A-Module 1+5, time relay Kl.15 ECU, lines
859924 gear CLBT 755: ECU error report oil temperature too high J1B:2L/1N E 1
report, emergency program
check cooling, sensor, ECU, lines
859931 gear CLBT 755: ECU error report shift selector signal (secondary) defective/missing J E 1
report
check ECU, cabling, no second travel switch installed!
859932 gear CLBT 755: ECU error report direction signal defective J1B:1R/3P/3N E 1
859933 gear CLBT 755: ECU error report oil temperature sensor outside the admissable measuring scale J1B:2L/1N E 1
report, emergency program
859934 gear CLBT 755: ECU error report internal memory test: PROM defective J1B E 1
replace ECU
070645 317
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
859941 gear CLBT 755: ECU error report solenoid valve J defective/missing J1B:3M/3L E 1
report
check ECU, valve, lines
859942 gear CLBT 755: ECU error report solenoid valve F defective/missing J1B:1W/2T E 1
report
check ECU, valve, lines
859943 gear CLBT 755: ECU error report solenoid valve D defective/missing J1B:1S/2T E 1
report
check ECU, valve, lines
859944 gear CLBT 755: ECU error report solenoid valve C defective/missing J1B:1S/3L E 1
report
check ECU, valve, lines
859945 gear CLBT 755: ECU error report solenoid valve B defective/missing J1B:1W/1T E 1
report
check ECU, valve, lines
859946 gear CLBT 755: ECU error report solenoid valve A defective/missing J1B:3T/1T E 1
report
check ECU, valve, lines
859951 gear CLBT 755: ECU error report solenoid valve G defective/missing J1B:2Y/1Y E 1
report
check ECU, valve, lines
859952 gear CLBT 755: ECU error report solenoid valve E defective/missing J1B:2W/3Y E 1
report
check ECU, valve, lines
859953 gear CLBT 755: ECU error report solenoid valve H defective/missing J1B:2M/3Y E 1
report
check ECU, valve, lines
859954 gear CLBT 755: ECU error report solenoid valve chain A, B, C, D, F, J defective J1B E 1
report
check ECU, valves, lines
070645 318
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
859966 gear CLBT 755: ECU error report bi-directional interface defective connection/transmission J1B E 1
report
incorrect ECU
859969 gear CLBT 755: ECU error report control device error/ test active J1B E 1
report
check ECU
880400 Engine chassis: CAN-Data transfer I/O-Module (ID90x) erroneous/maximum cycle time exceeded A700.X2: E 1
Emerg. op.: Momentum and RPM limitation of engine
Check cable / plug / I/O-Module(s)
880401 Engine chassis: CAN-Data transfer Coupling (ID 556) erroneous/maximum cycle time exceeded A700.X2: E 1
last received value or replacement value
Check cable / plug / coupling module
880402 Engine chassis: CAN-Data transfer Gear (ID564) erroneous/maximum cycle time exceeded A700.X2: E 1
last received value or replacement value
Check cable / plug / gear module
880403 Engine chassis: CAN-Data transfer Gear (ID564) erroneous/maximum cycle time exceeded A700.X2: E 1
last received value or replacement value
Check cable / plug / gear module
880404 Engine chassis: CAN-Data transfer Gear (ID668) erroneous/maximum cycle time exceeded A700.X2: E 1
last received value or replacement value
Check cable / plug / gear module
880405 Engine chassis: CAN-Data transfer ABV (ID512) erroneous/maximum cycle time exceeded A700.X2: E 1
last received value or replacement value
Check cable / plug / ABS/ASR-Module1
880406 Engine chassis: CAN-Data transfer ABV (ID513) erroneous/maximum cycle time exceeded A700.X2: E 1
last received value or replacement value
Check cable / plug / ABS/ASR-Module1
880407 Engine chassis: CAN-Data transfer ABV2 (ID514) erroneous/maximum cycle time exceeded A700.X2: E 1
last received value or replacement value
Check cable / plug / ABS/ASR-Module2
070645 319
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
880408 Engine chassis: CAN-Data transfer ABV2 (ID515) erroneous/maximum cycle time exceeded A700.X2: E 1
last received value or replacement value
Check cable / plug / ABS/ASR-Module2
880409 Engine chassis: CAN-Data transfer Retarder (ID 772) erroneous/maximum cycle time exceeded A700.X2: E 1
last received value or replacement value
Check cable / plug / retarder module
880410 Engine chassis: CAN-Data transfer WSK (ID 776) erroneous/maximum cycle time exceeded A700.X2: E 1
last received value or replacement value
Check cable / plug / converter module
880502 Engine chassis: CAN-engine control unit Data communication failed / interrupted (Sending timeout) A700.X2: E 1
last received value or replacement value
Check cable / plug / CAN-participant
880503 Engine chassis: CAN-engine control unit Data communication interrupted (Passive error) A700.X2: E 1
last received value or replacement value
Check cable / plug / CAN-participant
880504 Engine chassis: CAN-engine control unit Data communication interrupted (BusOff) A700.X2: E 1
last received value or replacement value
Check cable / plug / CAN-participant
880800 Engine chassis: CAN-Data transfer Data communication Tachograph problem A700.X2: E 2
Moment limitation of engine - dep. on configuration
Check cable / plug / tachograph
880801 Engine chassis: CAN-Data transfer Data communication TSC1 problem A700.X2: E 0
Engine shut off / emerg. op. - depending on configuration
Check cable / plug / CAN-participant
880802 Engine chassis: CAN-Data transfer Data communication failed / interrupted (Sending timeout) A700.X2: E 0
Engine shut off / emerg. op. - depending on configuration
Check cable / plug / CAN-participant
880803 Engine chassis: CAN-Data transfer Data communication interrupted (Passive error) A700.X2: E 2
Engine shut off / emerg. op. - depending on configuration
Check cable / plug / CAN-participant
070645 320
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
880804 Engine chassis: CAN-Data transfer Data communication interrupted (BusOff) A700.X2: E 2
Engine shut off / emerg. op. - depending on configuration
Check cable / plug / CAN-participant
881101 Engine chassis: Memory error EEPROM Check sum via parameter memory is erroneous A700 E 2
Engine cannot be started or engine shut off
Turn ignition off and on, if error not fixable, replace engine control unites
070645 321
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
881102 Engine chassis: Memory error EEPROM Parameter memory in EEPROM is invalid A700 E 2
Engine cannot be started or engine shut off
Turn ignition off and on, if error not fixable, replace engine control unites
881103 Engine chassis: Memory error EEPROM Check sum via ECU-Page is erroneous A700 E 0
No
Turn ignition off and on, if error not fixable, replace engine control unites
881104 Engine chassis: Memory error EEPROM Check sum via NMI-Page is erroneous A700 E 0
No
Turn ignition off and on, if error not fixable, replace engine control unites
881105 Engine chassis: Memory error EEPROM Check sum via Work data-Page is erroneous A700 E 0
No
Turn ignition off and on, if error not fixable, replace engine control unites
881106 Engine chassis: Memory error EEPROM Check sum via load collective is erroneous A700 E 0
No
Turn ignition off and on, if error not fixable, replace engine control unites
881107 Engine chassis: Memory error EEPROM Structure size of load collective has changed A700 E 0
No
Turn ignition off and on, if error not fixable, replace engine control unites
881108 Engine chassis: Memory error EEPROM EEPROM has insufficient memory for load collective free A700 E 0
No
Turn ignition off and on, if error not fixable, replace engine control unites
881200 Engine chassis: Power supply Supply voltage too low A700.X2: E 2
Engine cannot be started or engine shut off
Check power supply (battery, alternator, wiring, plug).
881201 Engine chassis: Power supply Supply voltage too high A700.X2: E 2
Engine cannot be started or engine shut off; only communication with diagnostics tool
Check power supply (battery, alternator, wiring, plug)
881202 Engine chassis: Power supply Digital output short circuit after supply voltage A700.X2: E 1
Engine shut off; only communication with diagnostics tool
Wiring, check engine control unit; replace engine control unit if nec.
070645 322
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
881203 Engine chassis: Power supply Error at release of power outputs A700.X2: E 1
Power outputs cannot be activated or deactivated
Wiring, check engine control unit; replace engine control unit if nec.
881204 Engine chassis: Power supply Current supply PS1 erroneous/missing A700.X2: E 2
Engine cannot be started or engine shut off
Check power supply (battery, alternator, wiring, plug) in rel. to PS1
881501 Engine chassis: Configuration error Full load curve (incorrect Offset) A700 E 1
The power curve match is limited internally
New data set, or replace engine control unit
882101 Engine chassis: Travel pedal maximum signal difference channel 1 and 2 exceeded A700 E 1
Use low value
Check wiring engine control unit to travel pedal. Check travel pedal / replace
070645 323
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
882900 Engine chassis: Air flap Short circuit after ground or broken wire A700.X2:12/13 E 1
Air vent is not actuated
Check cable harness / plug / air vent / engine control unit
882901 Engine chassis: Air flap short circuit to supply voltage A700.X2:12/13 E 1
Air vent is not actuated
Check cable harness / plug / air vent / engine control unit
882902 Engine chassis: Air flap Hardware error (Transistor defective) A700.X2:12/13 E 1
Air vent is not actuated
Check engine control unit
882905 Engine chassis: Air flap Logic threshold breach in shut off condition A700.X2:12/13 E 1
Air vent is not actuated
Check cable harness / plug / air vent / engine control unit
882906 Engine chassis: Air flap Logic threshold breach (Current less than perm. minimum value) A700.X2:12/13 E 1
Air vent is not actuated
Check cable harness / plug / air vent / engine control unit
882907 Engine chassis: Air flap Logic threshold breach (Current more than perm. maximum value) A700.X2:12/13 E 1
Air vent is not actuated
Check cable harness / plug / air vent / engine control unit
883003 Engine chassis: High pressure pump 1 Rule deviation negative A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
883004 Engine chassis: High pressure pump 1 Rule deviation positive A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
070645 324
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
883005 Engine chassis: High pressure pump 1 Current to high in shut off condition A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
883006 Engine chassis: High pressure pump 1 Current to low in actuated condition A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
883007 Engine chassis: High pressure pump 1 Current to high in actuated condition A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
883008 Engine chassis: High pressure pump 1 UeberCurrent LowSide (ground switch ) A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
883009 Engine chassis: High pressure pump 1 UeberCurrent HighSide (Plus-switch) A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
883103 Engine chassis: High pressure pump 2 Rule deviation negative A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
883104 Engine chassis: High pressure pump 2 Rule deviation positive A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
883105 Engine chassis: High pressure pump 2 Current to high in shut off condition A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
883106 Engine chassis: High pressure pump 2 Current to low in actuated condition A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
070645 325
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
883107 Engine chassis: High pressure pump 2 Current to high in actuated condition A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
883108 Engine chassis: High pressure pump 2 UeberCurrent LowSide (ground switch ) A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
883109 Engine chassis: High pressure pump 2 UeberCurrent HighSide (Plus-switch) A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
883300 Engine chassis: Fan control Short circuit after ground or broken wire A700.X2:26/27 E 1
The fan control is deactivated. Resulting in maximum vent position
Check wiring harness / plug / fan proportional valve / engine control unit
883301 Engine chassis: Fan control short circuit to supply voltage A700.X2:26/27 E 1
The fan control is deactivated. Resulting in maximum vent position
Check wiring harness / plug / fan proportional valve / engine control unit
883302 Engine chassis: Fan control Hardware error (Transistor defective) A700.X2:26/27 E 1
The fan control is deactivated. Resulting in maximum vent position
Check engine control unit
070645 326
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
883305 Engine chassis: Fan control Logic threshold breach in shut off condition A700.X2:26/27 E 1
The fan control is deactivated. Resulting in maximum vent position
Check wiring harness / plug / fan proportional valve / engine control unit
883306 Engine chassis: Fan control Logic threshold breach (Current less than perm. minimum value) A700.X2:26/27 E 1
The fan control is deactivated. Resulting in maximum vent position
Check wiring harness / plug / fan proportional valve / engine control unit
883307 Engine chassis: Fan control Logic threshold breach (Current more than perm. maximum value) A700.X2:26/27 E 1
The fan control is deactivated. Resulting in maximum vent position
Check wiring harness / plug / fan proportional valve / engine control unit
883400 Engine chassis: Engine brake Short circuit after ground or broken wire A700.X2:11 E 1
Engine brake flap is not actuated
Check cable harness / plug / engine brake flap / engine control unit
883401 Engine chassis: Engine brake short circuit to supply voltage A700.X2:11 E 1
Engine brake flap is not actuated
Check cable harness / plug / engine brake flap / engine control unit
883402 Engine chassis: Engine brake Hardware error (Transistor defective) A700.X2:11 E 1
Engine brake flap is not actuated
Check engine control unit
883405 Engine chassis: Engine brake Logic threshold breach in shut off condition A700.X2:11 E 1
Engine brake flap is not actuated
Check cable harness / plug / engine brake flap / engine control unit
070645 327
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
883406 Engine chassis: Engine brake Logic threshold breach (Current less than perm. minimum value) A700.X2:11 E 1
Engine brake flap is not actuated
Check cable harness / plug / engine brake flap / engine control unit
883407 Engine chassis: Engine brake Logic threshold breach (Current more than perm. maximum value) A700.X2:11 E 1
Engine brake flap is not actuated
Check cable harness / plug / engine brake flap / engine control unit
883500 Engine chassis: Heater flange unit 1 Short circuit after ground or broken wire A700.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
883501 Engine chassis: Heater flange unit 1 short circuit to supply voltage A700.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
883502 Engine chassis: Heater flange unit 1 Hardware error (Transistor defective) A700.X2:39/64 E 0
Failure of pre- and afterheat phase
Check engine control unit
883503 Engine chassis: Heater flange unit 1 Rule deviation negative A700.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
883504 Engine chassis: Heater flange unit 1 Rule deviation positive A700.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
883505 Engine chassis: Heater flange unit 1 Logic threshold breach in shut off condition A700.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
883506 Engine chassis: Heater flange unit 1 Logic threshold breach (Current less than perm. minimum value) A700.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
883507 Engine chassis: Heater flange unit 1 Logic threshold breach (Current more than perm. maximum value) A700.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
070645 328
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
883511 Engine chassis: Heater flange unit 1 No voltage on heater element A700.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
883512 Engine chassis: Heater flange unit 1 Voltage on heater element A700.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
883600 Engine chassis: Heater flange unit 2 Short circuit after ground or broken wire A700.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
883601 Engine chassis: Heater flange unit 2 short circuit to supply voltage A700.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
883602 Engine chassis: Heater flange unit 2 Hardware error (Transistor defective) A700.X2:25/65 E 0
Failure of pre- and afterheat phase
Check engine control unit
883603 Engine chassis: Heater flange unit 2 Rule deviation negative A700.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
883604 Engine chassis: Heater flange unit 2 Rule deviation positive A700.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
883605 Engine chassis: Heater flange unit 2 Logic threshold breach in shut off condition A700.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
883606 Engine chassis: Heater flange unit 2 Logic threshold breach (Current less than perm. minimum value) A700.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
883607 Engine chassis: Heater flange unit 2 Logic threshold breach (Current more than perm. maximum value) A700.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
070645 329
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
883611 Engine chassis: Heater flange unit 2 No voltage on heater element A700.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
883612 Engine chassis: Heater flange unit 2 Voltage on heater element A700.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
883700 Engine chassis: Solenoid valves Short circuit after ground or broken wire A700.X2:25/65 E 0
Failure of after heat phase
Check cable harness / plug / solenoid valve flame start system/ engine control unit
883701 Engine chassis: Solenoid valves short circuit to supply voltage A700.X2:25/65 E 0
Failure of after heat phase
Check cable harness / plug / solenoid valve flame start system/ engine control unit
883702 Engine chassis: Solenoid valves Hardware error (Transistor defective) A700.X2:25/65 E 0
Failure of after heat phase
Check engine control unit
883705 Engine chassis: Solenoid valves Logic threshold breach in shut off condition A700.X2:25/65 E 0
Failure of after heat phase
Check cable harness / plug / solenoid valve flame start system/ engine control unit
883706 Engine chassis: Solenoid valves Logic threshold breach (Current less than perm. minimum value) A700.X2:25/65 E 0
Failure of after heat phase
Check cable harness / plug / solenoid valve flame start system/ engine control unit
883707 Engine chassis: Solenoid valves Logic threshold breach (Current more than perm. maximum value) A700.X2:25/65 E 0
Failure of after heat phase
Check cable harness / plug / solenoid valve flame start system/ engine control unit
070645 330
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
883800 Engine chassis: Turbo charger Short circuit after ground or broken wire A700 E 0
Still to be defined
Check cable harness / plug / solenoid valve Turbo charger / engine control unit
883801 Engine chassis: Turbo charger short circuit to supply voltage A700 E 0
Still to be defined
Check cable harness / plug / solenoid valve Turbo charger / engine control unit
883802 Engine chassis: Turbo charger Hardware error (Transistor defective) A700 E 0
Still to be defined
Check engine control unit
883805 Engine chassis: Turbo charger Logic threshold breach in shut off condition A700 E 0
Still to be defined
Check cable harness / plug / solenoid valve Turbo charger / engine control unit
883806 Engine chassis: Turbo charger Logic threshold breach (Current less than perm. minimum value) A700 E 0
Still to be defined
Check cable harness / plug / solenoid valve Turbo charger / engine control unit
883807 Engine chassis: Turbo charger Logic threshold breach (Current more than perm. maximum value) A700 E 0
Still to be defined
Check cable harness / plug / solenoid valve Turbo charger / engine control unit
883900 Engine chassis: Exhaust return (AGR) Short circuit after ground or broken wire A700.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit
883901 Engine chassis: Exhaust return (AGR) short circuit to supply voltage A700.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit
070645 331
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
883902 Engine chassis: Exhaust return (AGR) Hardware error (Transistor defective) A700.X1: E 1
External AGR is not actuated
Check engine control unit
883903 Engine chassis: Exhaust return (AGR) Rule deviation negative A700.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit
883904 Engine chassis: Exhaust return (AGR) Rule deviation positive A700.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit
883905 Engine chassis: Exhaust return (AGR) Logic threshold breach (Current higher than perm. min. value) A700.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit
883906 Engine chassis: Exhaust return (AGR) Logic threshold breach (Current less than perm. minimum value) A700.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit
883907 Engine chassis: Exhaust return (AGR) Logic threshold breach (Current more than perm. maximum value) A700.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit
883911 Engine chassis: Exhaust return (AGR) open without actuation A700.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit
883912 Engine chassis: Exhaust return (AGR) closed despite actuation A700.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit
884000 Engine chassis: Emerg. Op. indicator Short circuit after ground or broken wire A700.X2:42 E 1
None
Check cable harness / plug / warn. light / engine control unit
884001 Engine chassis: Emerg. Op. indicator short circuit to supply voltage A700.X2:42 E 1
None
Check cable harness / plug / warn. light / engine control unit
070645 332
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
884002 Engine chassis: Emerg. Op. indicator Hardware error (Transistor defective) A700.X2:42 E 1
None
Check engine control unit
884100 Engine chassis: Indicator light preglow / start readiness Short circuit after ground or broken wire A700.X2:28 E 1
None
Check cable harness / plug / warn. light / engine control unit
884101 Engine chassis: Indicator light preglow / start readiness short circuit to supply voltage A700.X2:28 E 1
None
Check cable harness / plug / warn. light / engine control unit
884102 Engine chassis: Indicator light preglow / start readiness Hardware error (Transistor defective) A700.X2:28 E 1
None
Check engine control unit
884200 Engine chassis: Charge indicator Alternator Short circuit after ground or broken wire A700.X2:14 E 1
None
Check cable harness / plug / warn. light / engine control unit
884201 Engine chassis: Charge indicator Alternator short circuit to supply voltage A700.X2:14 E 1
None
Check cable harness / plug / warn. light / engine control unit
884202 Engine chassis: Charge indicator Alternator Hardware error (Transistor defective) A700.X2:14 E 1
None
Check engine control unit
884900 Engine chassis: RPM signal output Short circuit after ground or broken wire A700 E 1
None
Check cable harness / plug / connected. module
884901 Engine chassis: RPM signal output short circuit to supply voltage A700 E 1
None
Check cable harness / plug / connected. module
885000 Engine chassis: Cylinder A1 Current back test erroneous or broken wire A700.X1:22/8 E 0
No
Check cable / plug / solenoid valve / engine control unit
070645 333
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
885100 Engine chassis: Cylinder A2 Current back test erroneous or broken wire A700.X1:21/7 E 0
No
Check cable / plug / solenoid valve / engine control unit
070645 334
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
885200 Engine chassis: Cylinder A3 Current back test erroneous or broken wire A700.X1:20/6 E 0
No
Check cable / plug / solenoid valve / engine control unit
070645 335
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
885300 Engine chassis: Cylinder A4 Current back test erroneous or broken wire A700.X1:19/5 E 0
No
Check cable / plug / solenoid valve / engine control unit
070645 336
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
885800 Engine chassis: Cylinder B1 Current back test erroneous or broken wire A700.X1:18/4 E 0
No
Check cable / plug / solenoid valve / engine control unit
070645 337
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
885900 Engine chassis: Cylinder B2 Current back test erroneous or broken wire A700.X1:17/3 E 0
No
Check cable / plug / solenoid valve / engine control unit
070645 338
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
886000 Engine chassis: Cylinder B3 Current back test erroneous or broken wire A700.X1:16/2 E 0
No
Check cable / plug / solenoid valve / engine control unit
070645 339
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
886100 Engine chassis: Cylinder B4 Current back test erroneous or broken wire A700.X1:15/1 E 0
No
Check cable / plug / solenoid valve / engine control unit
070645 340
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
886903 Engine chassis: Injection system Short circuit Plus switch after ground on bank A A700 E 1
No
Check cable / plug / solenoid valve / engine control unit
886904 Engine chassis: Injection system Short circuit Plus switch after ground on bank B A700 E 1
No
Check cable / plug / solenoid valve / engine control unit
886905 Engine chassis: Injection system Short circuit Plus switch after supply voltage on bank A A700 E 1
No
Check cable / plug / solenoid valve / engine control unit
886906 Engine chassis: Injection system Short circuit Plus switch after supply voltage on bank B A700 E 1
No
Check cable / plug / solenoid valve / engine control unit
886907 Engine chassis: Injection system Short circuit Ground switch after ground on bank A A700 E 1
at CR-Motor occurs shut off of bank A
Check cable / plug / solenoid valve / engine control unit
886908 Engine chassis: Injection system Short circuit Ground switch after ground on bank B A700 E 1
at CR-Motor occurs shut off of bank B
Check cable / plug / solenoid valve / engine control unit
070645 341
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
886909 Engine chassis: Injection system Short circuit Ground switch after supply voltage on bank A A700 E 1
No
Check cable / plug / solenoid valve / engine control unit
886910 Engine chassis: Injection system Short circuit Ground switch after supply voltage on bank B A700 E 1
No
Check cable / plug / solenoid valve / engine control unit
887000 Engine chassis: Overspeed RPM sensor 1 Warning threshold exceeded A700 E 1
None
Check engine op. (excess. speed due to push op.); engine control unit
887001 Engine chassis: Overspeed RPM sensor 2 Warning threshold exceeded A700 E 1
None
Check engine op. (excess. speed due to push op.); engine control unit
887002 Engine chassis: Overspeed RPM sensor 1 Safety threshold exceeded A700 E 2
Engine shut off
Check engine op. (excess. speed due to push op.); engine control unit
887003 Engine chassis: Overspeed RPM sensor 2 Safety threshold exceeded A700 E 2
Engine shut off
Check engine op. (excess. speed due to push op.); engine control unit
887103 Engine chassis: Synchronization not possible, RPM is too low A700 E 1
Engine start not possible
Turn ign. on / off; check RPM and phase sensor
070645 342
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
887104 Engine chassis: Synchronization Index counter camshaft gear erroneous A700 E 1
Engine start not possible
Turn ign. on / off; check RPM and phase sensor
887202 Engine chassis: RPM sensor 1 impermissible signal difference (Gradient breach) A700.X1:69/55/4 E 1
Em. shut off at simult. failure of redundant sensor (1 or 2). Otherwise RPM deter. via red. sensor 1
Check distance of RPM sensor to flywheel (0.5-2.0 mm); flywheel, wiring to RPM sensor
887302 Engine chassis: RPM sensor 2 impermissible signal difference (Gradient breach) A700.X1:68/54/4 E 1
Em. shut off at simult. failure of redundant sensor (1 or 2). Otherwise RPM deter. via red. sensor 0
Check distance of RPM sensor to flywheel (0.5-2.0 mm); flywheel, wiring to RPM sensor
070645 343
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
887500 Engine chassis: Travel pedal channel 1 Short circuit after ground or line interruption A700.X2:33/34/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)
887501 Engine chassis: Travel pedal channel 1 short circuit to supply voltage A700.X2:33/34/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
887502 Engine chassis: Travel pedal channel 1 Supply voltage Short circuit after ground A700.X2:33/34/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring engine control unit/Sensor (Short circuit after ground)
887503 Engine chassis: Travel pedal channel 1 Supply voltage Short circuit after supply voltage A700.X2:33/34/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
887504 Engine chassis: Travel pedal channel 1 Signal outside permissible range (Limit 1) A700.X2:33/34/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 5
Check medium for operating range problem. If nec., remedy mechanical problem
887505 Engine chassis: Travel pedal channel 1 Signal outside permissible range (Limit 2) A700.X2:33/34/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 5
Check medium for operating range problem. If nec., remedy mechanical problem
887600 Engine chassis: Travel pedal channel 2 Short circuit after ground or line interruption A700.X2:47/48/4 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 9
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)
887601 Engine chassis: Travel pedal channel 2 short circuit to supply voltage A700.X2:47/48/4 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 9
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
070645 344
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
887602 Engine chassis: Travel pedal channel 2 Supply voltage Short circuit after ground A700.X2:47/48/4 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 9
Check wiring engine control unit/Sensor (Short circuit after ground)
887603 Engine chassis: Travel pedal channel 2 Supply voltage Short circuit after supply voltage A700.X2:47/48/4 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 9
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
887604 Engine chassis: Travel pedal channel 2 Signal outside permissible range (Limit 1) A700.X2:47/48/4 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 9
Check medium for operating range problem. If nec., remedy mechanical problem
887605 Engine chassis: Travel pedal channel 2 Signal outside permissible range (Limit 2) A700.X2:47/48/4 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 9
Check medium for operating range problem. If nec., remedy mechanical problem
887700 Engine chassis: Sensor coolant level Short circuit after ground or line interruption A700.X2:19/20/2 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)
887701 Engine chassis: Sensor coolant level short circuit to supply voltage A700.X2:19/20/2 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
887702 Engine chassis: Sensor coolant level Supply voltage Short circuit after ground A700.X2:19/20/2 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring engine control unit/Sensor (Short circuit after ground)
887703 Engine chassis: Sensor coolant level Supply voltage Short circuit after supply voltage A700.X2:19/20/2 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
887704 Engine chassis: Sensor coolant level Signal outside permissible range (Limit 1) A700.X2:19/20/2 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 1
Check medium for operating range problem. If nec., remedy mechanical problem
887705 Engine chassis: Sensor coolant level Signal outside permissible range (Limit 2) A700.X2:19/20/2 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 1
Check medium for operating range problem. If nec., remedy mechanical problem
070645 345
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
887800 Engine chassis: Sensor oil level Short circuit after ground or line interruption A700 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)
887801 Engine chassis: Sensor oil level short circuit to supply voltage A700 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
887802 Engine chassis: Sensor oil level Supply voltage Short circuit after ground A700 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
887803 Engine chassis: Sensor oil level Supply voltage Short circuit after supply voltage A700 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
887804 Engine chassis: Sensor oil level Signal outside permissible range (Limit 1) A700 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
887805 Engine chassis: Sensor oil level Signal outside permissible range (Limit 2) A700 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
888400 Engine chassis: Sensor charge air pr, Short circuit after ground or line interruption A700.X1:61/47/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 3
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)
888401 Engine chassis: Sensor charge air pr, short circuit to supply voltage A700.X1:61/47/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 3
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
888402 Engine chassis: Sensor charge air pr, Supply voltage Short circuit after ground A700.X1:61/47/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 3
Check wiring engine control unit/Sensor (Short circuit after ground)
888403 Engine chassis: Sensor charge air pr, Supply voltage Short circuit after supply voltage A700.X1:61/47/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 3
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
070645 346
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
888404 Engine chassis: Sensor charge air pr, Signal outside permissible range (Limit 1) A700.X1:61/47/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 3
Check medium for operating range problem. If nec., remedy mechanical problem
888405 Engine chassis: Sensor charge air pr, Signal outside permissible range (Limit 2) A700.X1:61/47/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 3
Check medium for operating range problem. If nec., remedy mechanical problem
888500 Engine chassis: Sensor oil pr. Short circuit after ground or line interruption A700.X1:63/49/3 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)
888501 Engine chassis: Sensor oil pr. short circuit to supply voltage A700.X1:63/49/3 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
888502 Engine chassis: Sensor oil pr. Supply voltage Short circuit after ground A700.X1:63/49/3 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring engine control unit/Sensor (Short circuit after ground)
888503 Engine chassis: Sensor oil pr. Supply voltage Short circuit after supply voltage A700.X1:63/49/3 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
888504 Engine chassis: Sensor oil pr. Signal outside permissible range (Limit 1) A700.X1:63/49/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 5
Check medium for operating range problem. If nec., remedy mechanical problem
888505 Engine chassis: Sensor oil pr. Signal outside permissible range (Limit 2) A700.X1:63/49/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 5
Check medium for operating range problem. If nec., remedy mechanical problem
888600 Engine chassis: Sensor fuel pr. Short circuit after ground or line interruption A700.X1:62/48/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 4
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)
888601 Engine chassis: Sensor fuel pr. short circuit to supply voltage A700.X1:62/48/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 4
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
070645 347
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
888602 Engine chassis: Sensor fuel pr. Supply voltage Short circuit after ground A700.X1:62/48/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 4
Check wiring engine control unit/Sensor (Short circuit after ground)
888603 Engine chassis: Sensor fuel pr. Supply voltage Short circuit after supply voltage A700.X1:62/48/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 4
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
888604 Engine chassis: Sensor fuel pr. Signal outside permissible range (Limit 1) A700.X1:62/48/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 4
Check medium for operating range problem. If nec., remedy mechanical problem
888605 Engine chassis: Sensor fuel pr. Signal outside permissible range (Limit 2) A700.X1:62/48/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 4
Check medium for operating range problem. If nec., remedy mechanical problem
888700 Engine chassis: Sensor Air filter contamination Short circuit after ground or line interruption A700.X2:5/6/7 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)
888701 Engine chassis: Sensor Air filter contamination short circuit to supply voltage A700.X2:5/6/7 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
888702 Engine chassis: Sensor Air filter contamination Supply voltage Short circuit after ground A700.X2:5/6/7 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
888703 Engine chassis: Sensor Air filter contamination Supply voltage Short circuit after supply voltage A700.X2:5/6/7 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
888704 Engine chassis: Sensor Air filter contamination Signal outside permissible range (Limit 1) A700.X2:5/6/7 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
888705 Engine chassis: Sensor Air filter contamination Signal outside permissible range (Limit 2) A700.X2:5/6/7 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
070645 348
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
888800 Engine chassis: Common Rail Pr. sensor 1 Short circuit after ground or line interruption A700.X1:60/46/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 2
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)
888801 Engine chassis: Common Rail Pr. sensor 1 short circuit to supply voltage A700.X1:60/46/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 2
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
888802 Engine chassis: Common Rail Pr. sensor 1 Supply voltage Short circuit after ground A700.X1:60/46/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 2
Check wiring engine control unit/Sensor (Short circuit after ground)
888803 Engine chassis: Common Rail Pr. sensor 1 Supply voltage Short circuit after supply voltage A700.X1:60/46/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 2
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
888804 Engine chassis: Common Rail Pr. sensor 1 Signal outside permissible range (Limit 1) A700.X1:60/46/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 2
Check medium for operating range problem. If nec., remedy mechanical problem
888805 Engine chassis: Common Rail Pr. sensor 1 Signal outside permissible range (Limit 2) A700.X1:60/46/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 2
Check medium for operating range problem. If nec., remedy mechanical problem
888900 Engine chassis: Common Rail Pr. sensor 2 Short circuit after ground or line interruption A700.X1:59/45/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)
888901 Engine chassis: Common Rail Pr. sensor 2 short circuit to supply voltage A700.X1:59/45/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
888902 Engine chassis: Common Rail Pr. sensor 2 Supply voltage Short circuit after ground A700.X1:59/45/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring engine control unit/Sensor (Short circuit after ground)
888903 Engine chassis: Common Rail Pr. sensor 2 Supply voltage Short circuit after supply voltage A700.X1:59/45/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
070645 349
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
888904 Engine chassis: Common Rail Pr. sensor 2 Signal outside permissible range (Limit 1) A700.X1:59/45/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 1
Check medium for operating range problem. If nec., remedy mechanical problem
888905 Engine chassis: Common Rail Pr. sensor 2 Signal outside permissible range (Limit 2) A700.X1:59/45/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 1
Check medium for operating range problem. If nec., remedy mechanical problem
889000 Engine chassis: Sensor ambient pr. Short circuit after ground or line interruption A700 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)
889001 Engine chassis: Sensor ambient pr. short circuit to supply voltage A700 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
889002 Engine chassis: Sensor ambient pr. Supply voltage Short circuit after ground A700 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
889003 Engine chassis: Sensor ambient pr. Supply voltage Short circuit after supply voltage A700 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
889300 Engine chassis: Sensor Water in fuel short circuit to ground A700.X2: E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
889301 Engine chassis: Sensor Water in fuel short circuit to supply voltage A700.X2: E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)
889302 Engine chassis: Sensor Water in fuel Supply voltage Short circuit after ground A700.X2: E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
889303 Engine chassis: Sensor Water in fuel Supply voltage Short circuit after supply voltage A700.X2: E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
070645 350
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
889304 Engine chassis: Sensor Water in fuel Signal outside permissible range (Limit 1) A700.X2: E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
889305 Engine chassis: Sensor Water in fuel Signal outside permissible range (Limit 2) A700.X2: E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
889401 Engine chassis: Sensor Intercooler-Temperature short circuit to supply voltage A700.X2: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)
889402 Engine chassis: Sensor Intercooler-Temperature Supply voltage Short circuit after ground A700.X2: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
889403 Engine chassis: Sensor Intercooler-Temperature Supply voltage Short circuit after supply voltage A700.X2: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
889404 Engine chassis: Sensor Intercooler-Temperature Signal outside permissible range (Limit 1) A700.X2: E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
889405 Engine chassis: Sensor Intercooler-Temperature Signal outside permissible range (Limit 2) A700.X2: E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
889500 Engine chassis: Oil temperature sensor short circuit to ground A700.X2:46/60 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
889501 Engine chassis: Oil temperature sensor short circuit to supply voltage A700.X2:46/60 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)
070645 351
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
889502 Engine chassis: Oil temperature sensor Supply voltage Short circuit after ground A700.X2:46/60 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
889503 Engine chassis: Oil temperature sensor Supply voltage Short circuit after supply voltage A700.X2:46/60 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
889504 Engine chassis: Oil temperature sensor Signal outside permissible range (Limit 1) A700.X2:46/60 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
889505 Engine chassis: Oil temperature sensor Signal outside permissible range (Limit 2) A700.X2:46/60 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
889600 Engine chassis: Sensor fuel temperature short circuit to ground A700.X1:38/52 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
889601 Engine chassis: Sensor fuel temperature short circuit to supply voltage A700.X1:38/52 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)
889602 Engine chassis: Sensor fuel temperature Supply voltage Short circuit after ground A700.X1:38/52 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
889603 Engine chassis: Sensor fuel temperature Supply voltage Short circuit after supply voltage A700.X1:38/52 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
889604 Engine chassis: Sensor fuel temperature Signal outside permissible range (Limit 1) A700.X1:38/52 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
889605 Engine chassis: Sensor fuel temperature Signal outside permissible range (Limit 2) A700.X1:38/52 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
070645 352
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
889700 Engine chassis: Sensor charge air temperature short circuit to ground A700.X1: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
889701 Engine chassis: Sensor charge air temperature short circuit to supply voltage A700.X1: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)
889702 Engine chassis: Sensor charge air temperature Supply voltage Short circuit after ground A700.X1: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
889703 Engine chassis: Sensor charge air temperature Supply voltage Short circuit after supply voltage A700.X1: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
889704 Engine chassis: Sensor charge air temperature Signal outside permissible range (Limit 1) A700.X1: E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
889705 Engine chassis: Sensor charge air temperature Signal outside permissible range (Limit 2) A700.X1: E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
889800 Engine chassis: Sensor coolant temperature short circuit to ground A700.X1:51/37 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
889801 Engine chassis: Sensor coolant temperature short circuit to supply voltage A700.X1:51/37 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)
889802 Engine chassis: Sensor coolant temperature Supply voltage Short circuit after ground A700.X1:51/37 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
889803 Engine chassis: Sensor coolant temperature Supply voltage Short circuit after supply voltage A700.X1:51/37 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
070645 353
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
889804 Engine chassis: Sensor coolant temperature Signal outside permissible range (Limit 1) A700.X1:51/37 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
889805 Engine chassis: Sensor coolant temperature Signal outside permissible range (Limit 2) A700.X1:51/37 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
889900 Engine chassis: Sensor internal temperature short circuit to ground A700 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
889901 Engine chassis: Sensor internal temperature short circuit to supply voltage A700 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)
889902 Engine chassis: Sensor internal temperature Supply voltage Short circuit after ground A700 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
889903 Engine chassis: Sensor internal temperature Supply voltage Short circuit after supply voltage A700 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
889904 Engine chassis: Sensor internal temperature Signal outside permissible range (Limit 1) A700 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
889905 Engine chassis: Sensor internal temperature Signal outside permissible range (Limit 2) A700 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
890400 Engine uppercarr. CAN-Data transfer I/O-Module (ID90x) erroneous/maximum cycle time exceeded A750.X2: E 1
Emerg. op.: Momentum and RPM limitation of engine
Check cable / plug / I/O-Module(s)
890401 Engine uppercarr. CAN-Data transfer Coupling (ID 556) erroneous/maximum cycle time exceeded A750.X2: E 1
last received value or replacement value
Check cable / plug / coupling module
070645 354
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
890402 Engine uppercarr. CAN-Data transfer Gear (ID564) erroneous/maximum cycle time exceeded A750.X2: E 1
last received value or replacement value
Check cable / plug / gear module
890403 Engine uppercarr. CAN-Data transfer Gear (ID564) erroneous/maximum cycle time exceeded A750.X2: E 1
last received value or replacement value
Check cable / plug / gear module
890404 Engine uppercarr. CAN-Data transfer Gear (ID668) erroneous/maximum cycle time exceeded A750.X2: E 1
last received value or replacement value
Check cable / plug / gear module
890405 Engine uppercarr. CAN-Data transfer ABV (ID512) erroneous/maximum cycle time exceeded A750.X2: E 1
last received value or replacement value
Check cable / plug / ABS/ASR-Module1
890406 Engine uppercarr. CAN-Data transfer ABV (ID513) erroneous/maximum cycle time exceeded A750.X2: E 1
last received value or replacement value
Check cable / plug / ABS/ASR-Module1
890407 Engine uppercarr. CAN-Data transfer ABV2 (ID514) erroneous/maximum cycle time exceeded A750.X2: E 1
last received value or replacement value
Check cable / plug / ABS/ASR-Module2
890408 Engine uppercarr. CAN-Data transfer ABV2 (ID515) erroneous/maximum cycle time exceeded A750.X2: E 1
last received value or replacement value
Check cable / plug / ABS/ASR-Module2
890409 Engine uppercarr. CAN-Data transfer Retarder (ID 772) erroneous/maximum cycle time exceeded A750.X2: E 1
last received value or replacement value
Check cable / plug / retarder module
890410 Engine uppercarr. CAN-Data transfer WSK (ID 776) erroneous/maximum cycle time exceeded A750.X2: E 1
last received value or replacement value
Check cable / plug / converter module
890502 Engine uppercarr. CAN-engine control unit Data communication failed / interrupted (Sending timeout) A750.X2: E 1
last received value or replacement value
Check cable / plug / CAN-participant
070645 355
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
890503 Engine uppercarr. CAN-engine control unit Data communication interrupted (Passive error) A750.X2: E 1
last received value or replacement value
Check cable / plug / CAN-participant
890504 Engine uppercarr. CAN-engine control unit Data communication interrupted (BusOff) A750.X2: E 1
last received value or replacement value
Check cable / plug / CAN-participant
890800 Engine uppercarr. CAN-Data transfer Data communication Tachograph problem A750.X2: E 2
Moment limitation of engine - dep. on configuration
Check cable / plug / tachograph
890801 Engine uppercarr. CAN-Data transfer Data communication TSC1 problem A750.X2: E 0
Engine shut off / emerg. op. - depending on configuration
Check cable / plug / CAN-participant
890802 Engine uppercarr. CAN-Data transfer Data communication failed / interrupted (Sending timeout) A750.X2: E 0
Engine shut off / emerg. op. - depending on configuration
Check cable / plug / CAN-participant
890803 Engine uppercarr. CAN-Data transfer Data communication interrupted (Passive error) A750.X2: E 2
Engine shut off / emerg. op. - depending on configuration
Check cable / plug / CAN-participant
890804 Engine uppercarr. CAN-Data transfer Data communication interrupted (BusOff) A750.X2: E 2
Engine shut off / emerg. op. - depending on configuration
Check cable / plug / CAN-participant
070645 356
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
891101 Engine uppercarr. Memory error EEPROM Check sum via parameter memory is erroneous A750 E 2
Engine cannot be started or engine shut off
Turn ignition off and on, if error not fixable, replace engine control unites
891102 Engine uppercarr. Memory error EEPROM Parameter memory in EEPROM is invalid A750 E 2
Engine cannot be started or engine shut off
Turn ignition off and on, if error not fixable, replace engine control unites
891103 Engine uppercarr. Memory error EEPROM Check sum via ECU-Page is erroneous A750 E 0
No
Turn ignition off and on, if error not fixable, replace engine control unites
891104 Engine uppercarr. Memory error EEPROM Check sum via NMI-Page is erroneous A750 E 0
No
Turn ignition off and on, if error not fixable, replace engine control unites
891105 Engine uppercarr. Memory error EEPROM Check sum via Work data-Page is erroneous A750 E 0
No
Turn ignition off and on, if error not fixable, replace engine control unites
070645 357
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
891106 Engine uppercarr. Memory error EEPROM Check sum via load collective is erroneous A750 E 0
No
Turn ignition off and on, if error not fixable, replace engine control unites
891107 Engine uppercarr. Memory error EEPROM Structure size of load collective has changed A750 E 0
No
Turn ignition off and on, if error not fixable, replace engine control unites
891108 Engine uppercarr. Memory error EEPROM EEPROM has insufficient memory for load collective free A750 E 0
No
Turn ignition off and on, if error not fixable, replace engine control unites
891200 Engine uppercarr. Power supply Supply voltage too low A750.X2: E 2
Engine cannot be started or engine shut off
Check power supply (battery, alternator, wiring, plug).
891201 Engine uppercarr. Power supply Supply voltage too high A750.X2: E 2
Engine cannot be started or engine shut off; only communication with diagnostics tool
Check power supply (battery, alternator, wiring, plug)
891202 Engine uppercarr. Power supply Digital output short circuit after supply voltage A750.X2: E 1
Engine shut off; only communication with diagnostics tool
Wiring, check engine control unit; replace engine control unit if nec.
891203 Engine uppercarr. Power supply Error at release of power outputs A750.X2: E 1
Power outputs cannot be activated or deactivated
Wiring, check engine control unit; replace engine control unit if nec.
891204 Engine uppercarr. Power supply Current supply PS1 erroneous/missing A750.X2: E 2
Engine cannot be started or engine shut off
Check power supply (battery, alternator, wiring, plug) in rel. to PS1
891501 Engine uppercarr. Configuration error Full load curve (incorrect Offset) A750 E 1
The power curve match is limited internally
New data set, or replace engine control unit
070645 358
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
892101 Engine uppercarr. Travel pedal maximum signal difference channel 1 and 2 exceeded A750 E 1
Use low value
Check wiring engine control unit to travel pedal. Check travel pedal / replace
892900 Engine uppercarr. Air flap Short circuit after ground or broken wire A750.X2:12/13 E 1
Air vent is not actuated
Check cable harness / plug / air vent / engine control unit
892901 Engine uppercarr. Air flap short circuit to supply voltage A750.X2:12/13 E 1
Air vent is not actuated
Check cable harness / plug / air vent / engine control unit
892902 Engine uppercarr. Air flap Hardware error (Transistor defective) A750.X2:12/13 E 1
Air vent is not actuated
Check engine control unit
070645 359
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
892905 Engine uppercarr. Air flap Logic threshold breach in shut off condition A750.X2:12/13 E 1
Air vent is not actuated
Check cable harness / plug / air vent / engine control unit
892906 Engine uppercarr. Air flap Logic threshold breach (Current less than perm. minimum value) A750.X2:12/13 E 1
Air vent is not actuated
Check cable harness / plug / air vent / engine control unit
892907 Engine uppercarr. Air flap Logic threshold breach (Current more than perm. maximum value) A750.X2:12/13 E 1
Air vent is not actuated
Check cable harness / plug / air vent / engine control unit
893003 Engine uppercarr. High pressure pump 1 Rule deviation negative A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
893004 Engine uppercarr. High pressure pump 1 Rule deviation positive A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
893005 Engine uppercarr. High pressure pump 1 Current to high in shut off condition A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
893006 Engine uppercarr. High pressure pump 1 Current to low in actuated condition A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
893007 Engine uppercarr. High pressure pump 1 Current to high in actuated condition A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
893008 Engine uppercarr. High pressure pump 1 UeberCurrent LowSide (ground switch ) A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
070645 360
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
893009 Engine uppercarr. High pressure pump 1 UeberCurrent HighSide (Plus-switch) A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
893103 Engine uppercarr. High pressure pump 2 Rule deviation negative A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
893104 Engine uppercarr. High pressure pump 2 Rule deviation positive A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
893105 Engine uppercarr. High pressure pump 2 Current to high in shut off condition A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
893106 Engine uppercarr. High pressure pump 2 Current to low in actuated condition A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
893107 Engine uppercarr. High pressure pump 2 Current to high in actuated condition A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
893108 Engine uppercarr. High pressure pump 2 UeberCurrent LowSide (ground switch ) A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
893109 Engine uppercarr. High pressure pump 2 UeberCurrent HighSide (Plus-switch) A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit
070645 361
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
893300 Engine uppercarr. Fan control Short circuit after ground or broken wire A750.X2:26/27 E 1
The fan control is deactivated. Resulting in maximum vent position
Check wiring harness / plug / fan proportional valve / engine control unit
893301 Engine uppercarr. Fan control short circuit to supply voltage A750.X2:26/27 E 1
The fan control is deactivated. Resulting in maximum vent position
Check wiring harness / plug / fan proportional valve / engine control unit
893302 Engine uppercarr. Fan control Hardware error (Transistor defective) A750.X2:26/27 E 1
The fan control is deactivated. Resulting in maximum vent position
Check engine control unit
893305 Engine uppercarr. Fan control Logic threshold breach in shut off condition A750.X2:26/27 E 1
The fan control is deactivated. Resulting in maximum vent position
Check wiring harness / plug / fan proportional valve / engine control unit
893306 Engine uppercarr. Fan control Logic threshold breach (Current less than perm. minimum value) A750.X2:26/27 E 1
The fan control is deactivated. Resulting in maximum vent position
Check wiring harness / plug / fan proportional valve / engine control unit
893307 Engine uppercarr. Fan control Logic threshold breach (Current more than perm. maximum value) A750.X2:26/27 E 1
The fan control is deactivated. Resulting in maximum vent position
Check wiring harness / plug / fan proportional valve / engine control unit
070645 362
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
893400 Engine uppercarr. Engine brake Short circuit after ground or broken wire A750.X2:11 E 1
Engine brake flap is not actuated
Check cable harness / plug / engine brake flap / engine control unit
893401 Engine uppercarr. Engine brake short circuit to supply voltage A750.X2:11 E 1
Engine brake flap is not actuated
Check cable harness / plug / engine brake flap / engine control unit
893402 Engine uppercarr. Engine brake Hardware error (Transistor defective) A750.X2:11 E 1
Engine brake flap is not actuated
Check engine control unit
893405 Engine uppercarr. Engine brake Logic threshold breach in shut off condition A750.X2:11 E 1
Engine brake flap is not actuated
Check cable harness / plug / engine brake flap / engine control unit
893406 Engine uppercarr. Engine brake Logic threshold breach (Current less than perm. minimum value) A750.X2:11 E 1
Engine brake flap is not actuated
Check cable harness / plug / engine brake flap / engine control unit
893407 Engine uppercarr. Engine brake Logic threshold breach (Current more than perm. maximum value) A750.X2:11 E 1
Engine brake flap is not actuated
Check cable harness / plug / engine brake flap / engine control unit
893500 Engine uppercarr. Heater flange unit 1 Short circuit after ground or broken wire A750.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
893501 Engine uppercarr. Heater flange unit 1 short circuit to supply voltage A750.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
070645 363
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
893502 Engine uppercarr. Heater flange unit 1 Hardware error (Transistor defective) A750.X2:39/64 E 0
Failure of pre- and afterheat phase
Check engine control unit
893503 Engine uppercarr. Heater flange unit 1 Rule deviation negative A750.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
893504 Engine uppercarr. Heater flange unit 1 Rule deviation positive A750.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
893505 Engine uppercarr. Heater flange unit 1 Logic threshold breach in shut off condition A750.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
893506 Engine uppercarr. Heater flange unit 1 Logic threshold breach (Current less than perm. minimum value) A750.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
893507 Engine uppercarr. Heater flange unit 1 Logic threshold breach (Current more than perm. maximum value) A750.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
893511 Engine uppercarr. Heater flange unit 1 No voltage on heater element A750.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
893512 Engine uppercarr. Heater flange unit 1 Voltage on heater element A750.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
893600 Engine uppercarr. Heater flange unit 2 Short circuit after ground or broken wire A750.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
893601 Engine uppercarr. Heater flange unit 2 short circuit to supply voltage A750.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
070645 364
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
893602 Engine uppercarr. Heater flange unit 2 Hardware error (Transistor defective) A750.X2:25/65 E 0
Failure of pre- and afterheat phase
Check engine control unit
893603 Engine uppercarr. Heater flange unit 2 Rule deviation negative A750.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
893604 Engine uppercarr. Heater flange unit 2 Rule deviation positive A750.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
893605 Engine uppercarr. Heater flange unit 2 Logic threshold breach in shut off condition A750.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
893606 Engine uppercarr. Heater flange unit 2 Logic threshold breach (Current less than perm. minimum value) A750.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
893607 Engine uppercarr. Heater flange unit 2 Logic threshold breach (Current more than perm. maximum value) A750.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
893611 Engine uppercarr. Heater flange unit 2 No voltage on heater element A750.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
893612 Engine uppercarr. Heater flange unit 2 Voltage on heater element A750.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit
893700 Engine uppercarr. Solenoid valves Short circuit after ground or broken wire A750.X2:25/65 E 0
Failure of after heat phase
Check cable harness / plug / solenoid valve flame start system/ engine control unit
893701 Engine uppercarr. Solenoid valves short circuit to supply voltage A750.X2:25/65 E 0
Failure of after heat phase
Check cable harness / plug / solenoid valve flame start system/ engine control unit
070645 365
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
893702 Engine uppercarr. Solenoid valves Hardware error (Transistor defective) A750.X2:25/65 E 0
Failure of after heat phase
Check engine control unit
893705 Engine uppercarr. Solenoid valves Logic threshold breach in shut off condition A750.X2:25/65 E 0
Failure of after heat phase
Check cable harness / plug / solenoid valve flame start system/ engine control unit
893706 Engine uppercarr. Solenoid valves Logic threshold breach (Current less than perm. minimum value) A750.X2:25/65 E 0
Failure of after heat phase
Check cable harness / plug / solenoid valve flame start system/ engine control unit
893707 Engine uppercarr. Solenoid valves Logic threshold breach (Current more than perm. maximum value) A750.X2:25/65 E 0
Failure of after heat phase
Check cable harness / plug / solenoid valve flame start system/ engine control unit
893800 Engine uppercarr. Turbo charger Short circuit after ground or broken wire A750 E 0
Still to be defined
Check cable harness / plug / solenoid valve Turbo charger / engine control unit
893801 Engine uppercarr. Turbo charger short circuit to supply voltage A750 E 0
Still to be defined
Check cable harness / plug / solenoid valve Turbo charger / engine control unit
893802 Engine uppercarr. Turbo charger Hardware error (Transistor defective) A750 E 0
Still to be defined
Check engine control unit
070645 366
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
893805 Engine uppercarr. Turbo charger Logic threshold breach in shut off condition A750 E 0
Still to be defined
Check cable harness / plug / solenoid valve Turbo charger / engine control unit
893806 Engine uppercarr. Turbo charger Logic threshold breach (Current less than perm. minimum value) A750 E 0
Still to be defined
Check cable harness / plug / solenoid valve Turbo charger / engine control unit
893807 Engine uppercarr. Turbo charger Logic threshold breach (Current more than perm. maximum value) A750 E 0
Still to be defined
Check cable harness / plug / solenoid valve Turbo charger / engine control unit
893900 Engine uppercarr. Exhaust return (AGR) Short circuit after ground or broken wire A750.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit
893901 Engine uppercarr. Exhaust return (AGR) short circuit to supply voltage A750.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit
893902 Engine uppercarr. Exhaust return (AGR) Hardware error (Transistor defective) A750.X1: E 1
External AGR is not actuated
Check engine control unit
893903 Engine uppercarr. Exhaust return (AGR) Rule deviation negative A750.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit
893904 Engine uppercarr. Exhaust return (AGR) Rule deviation positive A750.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit
893905 Engine uppercarr. Exhaust return (AGR) Logic threshold breach (Current higher than perm. min. value) A750.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit
070645 367
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
893906 Engine uppercarr. Exhaust return (AGR) Logic threshold breach (Current less than perm. minimum value) A750.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit
893907 Engine uppercarr. Exhaust return (AGR) Logic threshold breach (Current more than perm. maximum value) A750.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit
893911 Engine uppercarr. Exhaust return (AGR) open without actuation A750.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit
893912 Engine uppercarr. Exhaust return (AGR) closed despite actuation A750.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit
894000 Engine uppercarr. Emerg. Op. indicator Short circuit after ground or broken wire A750.X2:42 E 1
None
Check cable harness / plug / warn. light / engine control unit
894001 Engine uppercarr. Emerg. Op. indicator short circuit to supply voltage A750.X2:42 E 1
None
Check cable harness / plug / warn. light / engine control unit
894002 Engine uppercarr. Emerg. Op. indicator Hardware error (Transistor defective) A750.X2:42 E 1
None
Check engine control unit
894100 Engine uppercarr. Indicator light preglow / start readiness Short circuit after ground or broken wire A750.X2:28 E 1
None
Check cable harness / plug / warn. light / engine control unit
894101 Engine uppercarr. Indicator light preglow / start readiness short circuit to supply voltage A750.X2:28 E 1
None
Check cable harness / plug / warn. light / engine control unit
894102 Engine uppercarr. Indicator light preglow / start readiness Hardware error (Transistor defective) A750.X2:28 E 1
None
Check engine control unit
070645 368
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
894200 Engine uppercarr. Charge indicator Alternator Short circuit after ground or broken wire A750.X2:14 E 1
None
Check cable harness / plug / warn. light / engine control unit
894201 Engine uppercarr. Charge indicator Alternator short circuit to supply voltage A750.X2:14 E 1
None
Check cable harness / plug / warn. light / engine control unit
894202 Engine uppercarr. Charge indicator Alternator Hardware error (Transistor defective) A750.X2:14 E 1
None
Check engine control unit
894900 Engine uppercarr. RPM signal output Short circuit after ground or broken wire A750 E 1
None
Check cable harness / plug / connected. module
894901 Engine uppercarr. RPM signal output short circuit to supply voltage A750 E 1
None
Check cable harness / plug / connected. module
895000 Engine uppercarr. Cylinder A1 Current back test erroneous or broken wire A750.X1:22/8 E 0
No
Check cable / plug / solenoid valve / engine control unit
070645 369
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
895100 Engine uppercarr. Cylinder A2 Current back test erroneous or broken wire A750.X1:21/7 E 0
No
Check cable / plug / solenoid valve / engine control unit
070645 370
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
895200 Engine uppercarr. Cylinder A3 Current back test erroneous or broken wire A750.X1:20/6 E 0
No
Check cable / plug / solenoid valve / engine control unit
070645 371
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
895300 Engine uppercarr. Cylinder A4 Current back test erroneous or broken wire A750.X1:19/5 E 0
No
Check cable / plug / solenoid valve / engine control unit
070645 372
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
895800 Engine uppercarr. Cylinder B1 Current back test erroneous or broken wire A750.X1:18/4 E 0
No
Check cable / plug / solenoid valve / engine control unit
070645 373
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
895900 Engine uppercarr. Cylinder B2 Current back test erroneous or broken wire A750.X1:17/3 E 0
No
Check cable / plug / solenoid valve / engine control unit
896000 Engine uppercarr. Cylinder B3 Current back test erroneous or broken wire A750.X1:16/2 E 0
No
Check cable / plug / solenoid valve / engine control unit
070645 374
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
896100 Engine uppercarr. Cylinder B4 Current back test erroneous or broken wire A750.X1:15/1 E 0
No
Check cable / plug / solenoid valve / engine control unit
070645 375
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
070645 376
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
896903 Engine uppercarr. Injection system Short circuit Plus switch after ground on bank A A750 E 1
No
Check cable / plug / solenoid valve / engine control unit
896904 Engine uppercarr. Injection system Short circuit Plus switch after ground on bank B A750 E 1
No
Check cable / plug / solenoid valve / engine control unit
896905 Engine uppercarr. Injection system Short circuit Plus switch after supply voltage on bank A A750 E 1
No
Check cable / plug / solenoid valve / engine control unit
896906 Engine uppercarr. Injection system Short circuit Plus switch after supply voltage on bank B A750 E 1
No
Check cable / plug / solenoid valve / engine control unit
896907 Engine uppercarr. Injection system Short circuit Ground switch after ground on bank A A750 E 1
at CR-Motor occurs shut off of bank A
Check cable / plug / solenoid valve / engine control unit
896908 Engine uppercarr. Injection system Short circuit Ground switch after ground on bank B A750 E 1
at CR-Motor occurs shut off of bank B
Check cable / plug / solenoid valve / engine control unit
896909 Engine uppercarr. Injection system Short circuit Ground switch after supply voltage on bank A A750 E 1
No
Check cable / plug / solenoid valve / engine control unit
896910 Engine uppercarr. Injection system Short circuit Ground switch after supply voltage on bank B A750 E 1
No
Check cable / plug / solenoid valve / engine control unit
897000 Engine uppercarr. Overspeed RPM sensor 1 Warning threshold exceeded A750 E 1
None
Check engine op. (excess. speed due to push op.); engine control unit
897001 Engine uppercarr. Overspeed RPM sensor 2 Warning threshold exceeded A750 E 1
None
Check engine op. (excess. speed due to push op.); engine control unit
070645 377
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
897002 Engine uppercarr. Overspeed RPM sensor 1 Safety threshold exceeded A750 E 2
Engine shut off
Check engine op. (excess. speed due to push op.); engine control unit
897003 Engine uppercarr. Overspeed RPM sensor 2 Safety threshold exceeded A750 E 2
Engine shut off
Check engine op. (excess. speed due to push op.); engine control unit
897103 Engine uppercarr. Synchronization not possible, RPM is too low A750 E 1
Engine start not possible
Turn ign. on / off; check RPM and phase sensor
897104 Engine uppercarr. Synchronization Index counter camshaft gear erroneous A750 E 1
Engine start not possible
Turn ign. on / off; check RPM and phase sensor
897202 Engine uppercarr. RPM sensor 1 impermissible signal difference (Gradient breach) A750.X1:69/55/4 E 1
Em. shut off at simult. failure of redundant sensor (1 or 2). Otherwise RPM deter. via red. sensor 1
Check distance of RPM sensor to flywheel (0.5-2.0 mm); flywheel, wiring to RPM sensor
070645 378
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
897302 Engine uppercarr. RPM sensor 2 impermissible signal difference (Gradient breach) A750.X1:68/54/4 E 1
Em. shut off at simult. failure of redundant sensor (1 or 2). Otherwise RPM deter. via red. sensor 0
Check distance of RPM sensor to flywheel (0.5-2.0 mm); flywheel, wiring to RPM sensor
897500 Engine uppercarr. Travel pedal channel 1 Short circuit after ground or line interruption A750.X2:33/34/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)
897501 Engine uppercarr. Travel pedal channel 1 short circuit to supply voltage A750.X2:33/34/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
070645 379
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
897502 Engine uppercarr. Travel pedal channel 1 Supply voltage Short circuit after ground A750.X2:33/34/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring engine control unit/Sensor (Short circuit after ground)
897503 Engine uppercarr. Travel pedal channel 1 Supply voltage Short circuit after supply voltage A750.X2:33/34/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
897504 Engine uppercarr. Travel pedal channel 1 Signal outside permissible range (Limit 1) A750.X2:33/34/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 5
Check medium for operating range problem. If nec., remedy mechanical problem
897505 Engine uppercarr. Travel pedal channel 1 Signal outside permissible range (Limit 2) A750.X2:33/34/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 5
Check medium for operating range problem. If nec., remedy mechanical problem
897600 Engine uppercarr. Travel pedal channel 2 Short circuit after ground or line interruption A750.X2:47/48/4 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 9
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)
897601 Engine uppercarr. Travel pedal channel 2 short circuit to supply voltage A750.X2:47/48/4 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 9
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
897602 Engine uppercarr. Travel pedal channel 2 Supply voltage Short circuit after ground A750.X2:47/48/4 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 9
Check wiring engine control unit/Sensor (Short circuit after ground)
897603 Engine uppercarr. Travel pedal channel 2 Supply voltage Short circuit after supply voltage A750.X2:47/48/4 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 9
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
897604 Engine uppercarr. Travel pedal channel 2 Signal outside permissible range (Limit 1) A750.X2:47/48/4 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 9
Check medium for operating range problem. If nec., remedy mechanical problem
897605 Engine uppercarr. Travel pedal channel 2 Signal outside permissible range (Limit 2) A750.X2:47/48/4 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 9
Check medium for operating range problem. If nec., remedy mechanical problem
070645 380
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
897700 Engine uppercarr. Sensor coolant level Short circuit after ground or line interruption A750.X2:19/20/2 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)
897701 Engine uppercarr. Sensor coolant level short circuit to supply voltage A750.X2:19/20/2 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
897702 Engine uppercarr. Sensor coolant level Supply voltage Short circuit after ground A750.X2:19/20/2 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring engine control unit/Sensor (Short circuit after ground)
897703 Engine uppercarr. Sensor coolant level Supply voltage Short circuit after supply voltage A750.X2:19/20/2 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
897704 Engine uppercarr. Sensor coolant level Signal outside permissible range (Limit 1) A750.X2:19/20/2 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 1
Check medium for operating range problem. If nec., remedy mechanical problem
897705 Engine uppercarr. Sensor coolant level Signal outside permissible range (Limit 2) A750.X2:19/20/2 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 1
Check medium for operating range problem. If nec., remedy mechanical problem
897800 Engine uppercarr. Sensor oil level Short circuit after ground or line interruption A750 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)
897801 Engine uppercarr. Sensor oil level short circuit to supply voltage A750 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
897802 Engine uppercarr. Sensor oil level Supply voltage Short circuit after ground A750 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
897803 Engine uppercarr. Sensor oil level Supply voltage Short circuit after supply voltage A750 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
070645 381
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
897804 Engine uppercarr. Sensor oil level Signal outside permissible range (Limit 1) A750 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
897805 Engine uppercarr. Sensor oil level Signal outside permissible range (Limit 2) A750 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
898400 Engine uppercarr. Sensor charge air pr, Short circuit after ground or line interruption A750.X1:61/47/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 3
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)
898401 Engine uppercarr. Sensor charge air pr, short circuit to supply voltage A750.X1:61/47/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 3
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
898402 Engine uppercarr. Sensor charge air pr, Supply voltage Short circuit after ground A750.X1:61/47/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 3
Check wiring engine control unit/Sensor (Short circuit after ground)
898403 Engine uppercarr. Sensor charge air pr, Supply voltage Short circuit after supply voltage A750.X1:61/47/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 3
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
898404 Engine uppercarr. Sensor charge air pr, Signal outside permissible range (Limit 1) A750.X1:61/47/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 3
Check medium for operating range problem. If nec., remedy mechanical problem
898405 Engine uppercarr. Sensor charge air pr, Signal outside permissible range (Limit 2) A750.X1:61/47/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 3
Check medium for operating range problem. If nec., remedy mechanical problem
898500 Engine uppercarr. Sensor oil pr. Short circuit after ground or line interruption A750.X1:63/49/3 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)
898501 Engine uppercarr. Sensor oil pr. short circuit to supply voltage A750.X1:63/49/3 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
070645 382
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
898502 Engine uppercarr. Sensor oil pr. Supply voltage Short circuit after ground A750.X1:63/49/3 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring engine control unit/Sensor (Short circuit after ground)
898503 Engine uppercarr. Sensor oil pr. Supply voltage Short circuit after supply voltage A750.X1:63/49/3 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
898504 Engine uppercarr. Sensor oil pr. Signal outside permissible range (Limit 1) A750.X1:63/49/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 5
Check medium for operating range problem. If nec., remedy mechanical problem
898505 Engine uppercarr. Sensor oil pr. Signal outside permissible range (Limit 2) A750.X1:63/49/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 5
Check medium for operating range problem. If nec., remedy mechanical problem
898600 Engine uppercarr. Sensor fuel pr. Short circuit after ground or line interruption A750.X1:62/48/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 4
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)
898601 Engine uppercarr. Sensor fuel pr. short circuit to supply voltage A750.X1:62/48/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 4
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
898602 Engine uppercarr. Sensor fuel pr. Supply voltage Short circuit after ground A750.X1:62/48/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 4
Check wiring engine control unit/Sensor (Short circuit after ground)
898603 Engine uppercarr. Sensor fuel pr. Supply voltage Short circuit after supply voltage A750.X1:62/48/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 4
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
898604 Engine uppercarr. Sensor fuel pr. Signal outside permissible range (Limit 1) A750.X1:62/48/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 4
Check medium for operating range problem. If nec., remedy mechanical problem
898605 Engine uppercarr. Sensor fuel pr. Signal outside permissible range (Limit 2) A750.X1:62/48/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 4
Check medium for operating range problem. If nec., remedy mechanical problem
070645 383
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
898700 Engine uppercarr. Sensor Air filter contamination Short circuit after ground or line interruption A750.X2:5/6/7 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)
898701 Engine uppercarr. Sensor Air filter contamination short circuit to supply voltage A750.X2:5/6/7 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
898702 Engine uppercarr. Sensor Air filter contamination Supply voltage Short circuit after ground A750.X2:5/6/7 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
898703 Engine uppercarr. Sensor Air filter contamination Supply voltage Short circuit after supply voltage A750.X2:5/6/7 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
898704 Engine uppercarr. Sensor Air filter contamination Signal outside permissible range (Limit 1) A750.X2:5/6/7 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
898705 Engine uppercarr. Sensor Air filter contamination Signal outside permissible range (Limit 2) A750.X2:5/6/7 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
898800 Engine uppercarr. Common Rail Pr. sensor 1 Short circuit after ground or line interruption A750.X1:60/46/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 2
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)
898801 Engine uppercarr. Common Rail Pr. sensor 1 short circuit to supply voltage A750.X1:60/46/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 2
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
898802 Engine uppercarr. Common Rail Pr. sensor 1 Supply voltage Short circuit after ground A750.X1:60/46/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 2
Check wiring engine control unit/Sensor (Short circuit after ground)
898803 Engine uppercarr. Common Rail Pr. sensor 1 Supply voltage Short circuit after supply voltage A750.X1:60/46/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 2
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
070645 384
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
898804 Engine uppercarr. Common Rail Pr. sensor 1 Signal outside permissible range (Limit 1) A750.X1:60/46/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 2
Check medium for operating range problem. If nec., remedy mechanical problem
898805 Engine uppercarr. Common Rail Pr. sensor 1 Signal outside permissible range (Limit 2) A750.X1:60/46/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 2
Check medium for operating range problem. If nec., remedy mechanical problem
898900 Engine uppercarr. Common Rail Pr. sensor 2 Short circuit after ground or line interruption A750.X1:59/45/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)
898901 Engine uppercarr. Common Rail Pr. sensor 2 short circuit to supply voltage A750.X1:59/45/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
898902 Engine uppercarr. Common Rail Pr. sensor 2 Supply voltage Short circuit after ground A750.X1:59/45/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring engine control unit/Sensor (Short circuit after ground)
898903 Engine uppercarr. Common Rail Pr. sensor 2 Supply voltage Short circuit after supply voltage A750.X1:59/45/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
898904 Engine uppercarr. Common Rail Pr. sensor 2 Signal outside permissible range (Limit 1) A750.X1:59/45/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 1
Check medium for operating range problem. If nec., remedy mechanical problem
898905 Engine uppercarr. Common Rail Pr. sensor 2 Signal outside permissible range (Limit 2) A750.X1:59/45/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 1
Check medium for operating range problem. If nec., remedy mechanical problem
899000 Engine uppercarr. Sensor ambient pr. Short circuit after ground or line interruption A750 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)
899001 Engine uppercarr. Sensor ambient pr. short circuit to supply voltage A750 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
070645 385
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
899002 Engine uppercarr. Sensor ambient pr. Supply voltage Short circuit after ground A750 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
899003 Engine uppercarr. Sensor ambient pr. Supply voltage Short circuit after supply voltage A750 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
899300 Engine uppercarr. Sensor Water in fuel short circuit to ground A750.X2: E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
899301 Engine uppercarr. Sensor Water in fuel short circuit to supply voltage A750.X2: E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)
899302 Engine uppercarr. Sensor Water in fuel Supply voltage Short circuit after ground A750.X2: E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
899303 Engine uppercarr. Sensor Water in fuel Supply voltage Short circuit after supply voltage A750.X2: E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
899304 Engine uppercarr. Sensor Water in fuel Signal outside permissible range (Limit 1) A750.X2: E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
899305 Engine uppercarr. Sensor Water in fuel Signal outside permissible range (Limit 2) A750.X2: E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
899401 Engine uppercarr. Sensor Intercooler-Temperature short circuit to supply voltage A750.X2: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)
070645 386
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
899402 Engine uppercarr. Sensor Intercooler-Temperature Supply voltage Short circuit after ground A750.X2: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
899403 Engine uppercarr. Sensor Intercooler-Temperature Supply voltage Short circuit after supply voltage A750.X2: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
899404 Engine uppercarr. Sensor Intercooler-Temperature Signal outside permissible range (Limit 1) A750.X2: E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
899405 Engine uppercarr. Sensor Intercooler-Temperature Signal outside permissible range (Limit 2) A750.X2: E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
899500 Engine uppercarr. Oil temperature sensor short circuit to ground A750.X2:46/60 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
899501 Engine uppercarr. Oil temperature sensor short circuit to supply voltage A750.X2:46/60 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)
899502 Engine uppercarr. Oil temperature sensor Supply voltage Short circuit after ground A750.X2:46/60 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
899503 Engine uppercarr. Oil temperature sensor Supply voltage Short circuit after supply voltage A750.X2:46/60 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
899504 Engine uppercarr. Oil temperature sensor Signal outside permissible range (Limit 1) A750.X2:46/60 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
899505 Engine uppercarr. Oil temperature sensor Signal outside permissible range (Limit 2) A750.X2:46/60 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
070645 387
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
899600 Engine uppercarr. Sensor fuel temperature short circuit to ground A750.X1:38/52 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
899601 Engine uppercarr. Sensor fuel temperature short circuit to supply voltage A750.X1:38/52 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)
899602 Engine uppercarr. Sensor fuel temperature Supply voltage Short circuit after ground A750.X1:38/52 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
899603 Engine uppercarr. Sensor fuel temperature Supply voltage Short circuit after supply voltage A750.X1:38/52 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
899604 Engine uppercarr. Sensor fuel temperature Signal outside permissible range (Limit 1) A750.X1:38/52 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
899605 Engine uppercarr. Sensor fuel temperature Signal outside permissible range (Limit 2) A750.X1:38/52 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
899700 Engine uppercarr. Sensor charge air temperature short circuit to ground A750.X1: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
899701 Engine uppercarr. Sensor charge air temperature short circuit to supply voltage A750.X1: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)
899702 Engine uppercarr. Sensor charge air temperature Supply voltage Short circuit after ground A750.X1: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
899703 Engine uppercarr. Sensor charge air temperature Supply voltage Short circuit after supply voltage A750.X1: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
070645 388
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
899704 Engine uppercarr. Sensor charge air temperature Signal outside permissible range (Limit 1) A750.X1: E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
899705 Engine uppercarr. Sensor charge air temperature Signal outside permissible range (Limit 2) A750.X1: E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
899800 Engine uppercarr. Sensor coolant temperature short circuit to ground A750.X1:51/37 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
899801 Engine uppercarr. Sensor coolant temperature short circuit to supply voltage A750.X1:51/37 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)
899802 Engine uppercarr. Sensor coolant temperature Supply voltage Short circuit after ground A750.X1:51/37 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
899803 Engine uppercarr. Sensor coolant temperature Supply voltage Short circuit after supply voltage A750.X1:51/37 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
899804 Engine uppercarr. Sensor coolant temperature Signal outside permissible range (Limit 1) A750.X1:51/37 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
899805 Engine uppercarr. Sensor coolant temperature Signal outside permissible range (Limit 2) A750.X1:51/37 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
899900 Engine uppercarr. Sensor internal temperature short circuit to ground A750 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
899901 Engine uppercarr. Sensor internal temperature short circuit to supply voltage A750 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)
070645 389
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
899902 Engine uppercarr. Sensor internal temperature Supply voltage Short circuit after ground A750 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)
899903 Engine uppercarr. Sensor internal temperature Supply voltage Short circuit after supply voltage A750 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)
899904 Engine uppercarr. Sensor internal temperature Signal outside permissible range (Limit 1) A750 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
899905 Engine uppercarr. Sensor internal temperature Signal outside permissible range (Limit 2) A750 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem
930106 engine V8: control device engine Data communication CAN faulty / interrupted X275:1/4/7 E 1
emergency operation
check cable/plugs for shorts
930107 engine V8: control device engine Data communication CAN cancelled X275:1/4/7 E 1
emergency operation
check cable/plugs for UB- or shorts to ground
930208 engine V8: CAN-participant ABV (ABS/ASR) Data transfer faulty/missing, max. cycle time exceeded X275:1/4/7 E 1
limited function
check cable/plugs/ABS-/ASR-electronics
930308 engine V8: CAN-participant gear Data transfer faulty/missing, max. cycle time exceeded X275:1/4/7 E 1
limited function
check cable/plugs/gear electronics
930408 engine V8: CAN-participant E/A-Modul Data transfer faulty/missing, max. cycle time exceeded X275:1/4/7 E 1
emergency operation
check cable/plugs/E/A-Modul(e)
930508 engine V8: CAN signals gear Data transfer faulty/missing, max. cycle time exceeded X275:1/4/7 E 1
limited function
check cable/plugs/gear electronics
070645 390
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
930608 engine V8: CAN signals travel switch Data transfer faulty/missing, max. cycle time exceeded X275:1/4/7 E 1
limited function
check cable/plugs/E/A-Modul(e)
930910 engine V8: speed 1/2 inadmissable signal difference/plausability control defective X273:18/19/20/2 E 1
switch-over to other speed sensor or engine-stop 1
check cable/plugs/sensor, distance to flywheel
931002 engine V8: accelerator 1 sensor defect high/short circ. to supply voltage X274:16/17 E 1
switch-over to accelerator 2,speed limitation, torque limitation or 20-23
check cable/plugs for UB-shorts
931003 engine V8: accelerator 1 sensor defect low/short circuit to ground X274:16/17 E 1
switch-over to accelerator 2,speed limitation, torque limitation or 20-23
check cable/plugs for breaks or short to ground
931102 engine V8: accelerator 2 sensor defect high/short circ. to supply voltage X274:14/15 E 1
switch-over to accelerator 1, speed limitation, torque limitation or emergency operation at error code 16-19
check cable/plugs for UB-shorts
931103 engine V8: accelerator 2 sensor defect low/short circuit to ground X274:14/15 E 1
switch-over to accelerator 1, speed limitation, torque limitation or emergency operation at error code 16-19
check cable/plugs for breaks or short to ground
070645 391
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
931210 engine V8: accelerator 1/2 inadmissable signal difference/plausability control defective X274:14/15/16/1 E 1
gas withdrawal (idle) 7
check pedal unit, check condition of operation brake
931280 engine V8: accelerator 1/2 Actuation with selected/active auxiliary brake X274:14/15/16/1 B
Travel pedal lock 7
Release travel pedal, switch off auxiliary brake
931611 engine V8: trigger signal box EDC excess current recognition X271:7/10 E 1
engine-Stop
check cable/plugs, replace LH-ECU1, check EDC-actuator, if necessary replace injector pump
931701 engine V8: signal box feedback EDC unit defect X271:13/14/15 E 1
engine-Stop
check cable/plugs, replace LH-ECU1, check EDC-actuator, if necessary replace injector pump
070645 392
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
931917 engine V8: supply KL30 voltage below required value X272:1 E 1
generate error report; Reset: automatic after error counter sequence or regulator reset
check main circuit voltage, check battery
932012 engine V8: start engine KL50 short circuit to ground X274:13 E 1
generate error report; Reset: automatic after error counter sequence or regulator reset
check cable/plugs for short to ground
932112 engine V8: DA, flame type heater plugs diagnosis short circuit to ground X271:9 E 1
error report
check cable/plugs for short to ground, replace Relaismodul
932113 engine V8: DA, flame type heater plugs diagnosis open signal circuits X271:9 E 1
shut off FGK and MVE
check cable/plugs for breaks, replace Relaismodul
932114 engine V8: DA, flame type heater plugs diagnosis short circuit to supply voltage X271:9 E 1
error report
check cable/plugs for UB-shorts, replace Relaismodul
070645 393
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
932512 engine V8: Speed signal tachograph short circuit to ground X275:9 E 1
Signal is ignored, switch off of functions TMAT/TSET, reduction of maximum moment due to Vset
Check or replace line connection tachograph<->ECU, tachograph, ECU
932513 engine V8: Speed signal tachograph open signal circuits X275:9 E 1
Signal is ignored, switch off of functions TMAT/TSET, reduction of maximum moment due to Vset
Check or replace line connection tachograph<->ECU, tachograph, ECU
932514 engine V8: Speed signal tachograph short circuit to supply voltage X275:9 E 1
Signal is ignored, switch off of functions TMAT/TSET, reduction of maximum moment due to Vset
Check or replace line connection tachograph<->ECU, tachograph, ECU
932602 engine V8: oil pressure sensor sensor defect high/short circ. to supply voltage X273:1/2/3 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor
932603 engine V8: oil pressure sensor sensor defect low/short circuit to ground X273:1/2/3 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor
932702 engine V8: charge air pressure sensor sensor defect high/short circ. to supply voltage X273:4/5/6 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor
932703 engine V8: charge air pressure sensor sensor defect low/short circuit to ground X273:4/5/6 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor
932802 engine V8: air filter sensor sensor defect high/short circ. to supply voltage X273:7/8/9 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor
932803 engine V8: air filter sensor sensor defect low/short circuit to ground X273:7/8/9 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor
933102 engine V8: charge air temperature sensor sensor defect high/short circ. to supply voltage X273:12/15 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor
070645 394
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
933103 engine V8: charge air temperature sensor sensor defect low/short circuit to ground X273:12/15 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor
933202 engine V8: coolant temperature sensor sensor defect high/short circ. to supply voltage X273:10/11 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor
933203 engine V8: coolant temperature sensor sensor defect low/short circuit to ground X273:10/11 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor
933313 engine V8: coolant level sensor open signal circuits X274:10/11 E 1
signal ignored, substitute value used
check cable/plugs for defects or breaks, replace sensor
933402 engine V8: oil temperature sensor sensor defect high/short circ. to supply voltage X273:16/17 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor
933403 engine V8: oil temperature sensor sensor defect low/short circuit to ground X273:16/17 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor
933512 engine V8: Sensor jib-movement-detector (NBF) short circuit to ground X271:1/2 E 1
Change-over to power-regulated operation
Check line connection ECU<->NBF sensor, NBV sensor; Replace NBF sensor
933513 engine V8: Sensor jib-movement-detector (NBF) open signal circuits X271:1/2 E 1
Change-over to power-regulated operation
Check line connection ECU<->NBF sensor, NBV sensor; Replace NBF sensor
933514 engine V8: Sensor jib-movement-detector (NBF) short circuit to supply voltage X271:1/2 E 1
Change-over to power-regulated operation
Check line connection ECU<->NBF sensor, NBV sensor; Replace NBF sensor
933601 engine V8: trigger flame type heater plug(s) FGK unit defect X271:4 E 1
shut off FGK and MVE
check cable/plugs for defects or breaks, check FGK, replace Relaismodul
070645 395
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
933614 engine V8: trigger flame type heater plug(s) FGK short circuit to supply voltage X271:4 E 1
933615 engine V8: trigger flame type heater plug(s) FGK open electric circuit X271:4 E 1
error report
check cable/plugs for breaks, replace Relaismodul
933618 engine V8: trigger flame type heater plug(s) FGK excess temperature X271:4 E 1
shut off FGK and MVE
check cable/plugs for short to ground, replace Relaismodul
933714 engine V8: solenoid valve additional flow for starting short circuit to supply voltage X271:6 E 1
933715 engine V8: solenoid valve additional flow for starting open electric circuit X271:6 E 1
FSA data defective, FGK activation removed, MVE reset: automatic after error counter sequence, after regulator reset
933718 engine V8: solenoid valve additional flow for starting excess temperature X271:6 E 1
shut off FGK and MVE
check cable/plugs for short to ground, replace Relaismodul
933814 engine V8: engine start 50A short circuit to supply voltage X271:5 E 1
933815 engine V8: engine start 50A open electric circuit X271:5 E 1
starting procedure interrupted, shut down FGK and MVE
check cable/plugs for breaks, replace Relaismodul
933908 engine V8: CAN-signals retarder Data transfer faulty/missing, max. cycle time exceeded X27 E 1
limited function
Check cable/plug/RET-electronics/CAN-Bus system
070645 396
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
934008 engine V8: CAN-signals WSK Data transfer faulty/missing, max. cycle time exceeded X27 E 1
limited function
Check cable/plug/WSK-electronics/CAN-Bus system
replace ECU
934504 engine V8: Calculation spray begin (SB) level exceeded X271 E 1
Change-over to controlled injection-start operation (SB)
934505 engine V8: Calculation spray begin (SB) below minimum level X271 E 1
Change-over to controlled injection-start operation (SB)
934526 engine V8: Calculation spray begin (SB) No synchronisation possible X271 E 1
Change-over to controlled injection-start operation (SB)
Checking of OT signal transmitter and NBF
070645 397
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
936124 engine V8: charge air temperature pre-warning disruption limit 1 X273:12/15 E 1
warning, engine-protection-info, output reduction
reduce output, check air suction routing and engine
936125 engine V8: charge air temperature pre-warning disruption limit 2 X273:12/15 E 1
warning, engine-protection-info, output reduction
reduce output, if necessary shut off engine, check air suction routing and engine
936522 engine V8: air filter pressure pre-warning disruption limit 1 X273:7/8/9 E 1
pre-warning
replace air filter at next opportunity
936525 engine V8: air filter pressure pre-warning disruption limit 2 X273:7/8/9 E 1
warning
replace air filter immediately
070645 398
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
936824 engine V8: charge air pressure pre-warning disruption limit 1 X273:4/5/6 E 1
signal ignored, substitute value will be used, error report
check air suction routing
936825 engine V8: charge air pressure pre-warning disruption limit 2 X273:4/5/6 E 1
signal ignored, substitute value will be used, error report
check air suction routing
938250 engine V8: change engine oil filter service report interval 1 attained/exceeded X27 E 1
report
check and return
938350 engine V8: change engine oil service report interval 1 attained/exceeded X27 E 1
report
change oil and return
938351 engine V8: change engine oil service report interval 2 attained/exceeded X27 E 1
report
change oil and return
938352 engine V8: change engine oil service report interval 3 attained/exceeded X27 E 1
report
change oil and return
938353 engine V8: change engine oil service report interval 4 attained/exceeded X27 E 1
report
change oil and return
070645 399
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
938354 engine V8: change engine oil service report interval 5 attained/exceeded X27 E 1
report
change oil and return
938355 engine V8: change engine oil service report interval 6 attained/exceeded X27 E 1
report
change oil and return
938356 engine V8: change engine oil service report interval 7 attained/exceeded X27 E 1
report
change oil and return
938357 engine V8: change engine oil service report interval 8 attained/exceeded X27 E 1
report
change oil and return
938358 engine V8: change engine oil service report interval 9 attained/exceeded X27 E 1
report
change oil and return
938359 engine V8: change engine oil service report interval 10 attained/exceeded X27 E 1
report
change oil and return
938650 engine V8: check battery service report interval 1 attained/exceeded X27 E 1
report
check and return
938750 engine V8: change water filter service report interval 1 attained/exceeded X27 E 1
report
change filter and return
938850 engine V8: check antifreeze service report interval 1 attained/exceeded X27 E 1
report
check and return
938950 engine V8: fuel filter level 1 service report interval 1 attained/exceeded X27 E 1
report
change filter and return
070645 400
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
939050 engine V8: fuel filter level 2 service report interval 1 attained/exceeded X27 E 1
report
change filter and return
939150 engine V8: valve clearance service report interval 1 attained/exceeded X27 E 1
report
check and return
939250 engine V8: fuel injection valves service report interval 1 attained/exceeded X27 E 1
report
check and return
940106 Engine uppercarr. control device engine Data communication CAN faulty / interrupted X705:1/4/7 E 1
emergency operation
check cable/plugs for shorts
940107 Engine uppercarr. control device engine Data communication CAN cancelled X705:1/4/7 E 1
emergency operation
check cable/plugs for UB- or shorts to ground
940208 Engine uppercarr. CAN-participant ABV (ABS/ASR) Data transfer faulty/missing, max. cycle time exceeded X705:1/4/7 E 1
limited function
check cable/plugs/ABS-/ASR-electronics
940308 Engine uppercarr. CAN-participant gear Data transfer faulty/missing, max. cycle time exceeded X705:1/4/7 E 1
limited function
check cable/plugs/gear electronics
940408 Engine uppercarr. CAN-participant E/A-Modul Data transfer faulty/missing, max. cycle time exceeded X705:1/4/7 E 1
emergency operation
check cable/plugs/E/A-Modul(e)
070645 401
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
940910 Engine uppercarr. speed 1/2 inadmissable signal difference/plausability control defective X703:18/19/20/2 E 1
switch-over to other speed sensor or engine-stop 1
check cable/plugs/sensor, distance to flywheel
941002 Engine uppercarr. accelerator 1 sensor defect high/short circ. to supply voltage X704:16/17 E 1
switch-over to accelerator 2,speed limitation, torque limitation or 20-23
check cable/plugs for UB-shorts
941003 Engine uppercarr. accelerator 1 sensor defect low/short circuit to ground X704:16/17 E 1
switch-over to accelerator 2,speed limitation, torque limitation or 20-23
check cable/plugs for breaks or short to ground
941102 Engine uppercarr. accelerator 2 sensor defect high/short circ. to supply voltage X704:14/15 E 1
switch-over to accelerator 1, speed limitation, torque limitation or emergency operation at error code 16-19
check cable/plugs for UB-shorts
941103 Engine uppercarr. accelerator 2 sensor defect low/short circuit to ground X704:14/15 E 1
switch-over to accelerator 1, speed limitation, torque limitation or emergency operation at error code 16-19
check cable/plugs for breaks or short to ground
070645 402
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
941210 Engine uppercarr. accelerator 1/2 inadmissable signal difference/plausability control defective X704:14/15/16/1 E 1
gas withdrawal (idle) 7
check pedal unit, check condition of operation brake
941611 Engine uppercarr. trigger signal box EDC excess current recognition X701:7/10 E 1
engine-Stop
check cable/plugs, replace LH-ECU1, check EDC-actuator, if necessary replace injector pump
941701 Engine uppercarr. signal box feedback EDC unit defect X701:13/14/15 E 1
engine-Stop
check cable/plugs, replace LH-ECU1, check EDC-actuator, if necessary replace injector pump
941906 Engine uppercarr. supply KL30 Data communication CAN faulty / interrupted X702:1 E 1
generate error report Reset: automatic after error counter sequence or after regulator-reset
check main circuit voltage, check battery
941907 Engine uppercarr. supply KL30 Data communication CAN cancelled X702:1 E 1
generate error report; Reset: automatic after error counter sequence or regulator reset
check main circuit voltage, check battery
942012 Engine uppercarr. start engine KL50 short circuit to ground X704:13 E 1
generate error report; Reset: automatic after error counter sequence or regulator reset
check cable/plugs for short to ground
070645 403
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
942112 Engine uppercarr. DA, flame type heater plugs diagnosis short circuit to ground X701:9 E 1
error report
check cable/plugs for short to ground, replace Relaismodul
942113 Engine uppercarr. DA, flame type heater plugs diagnosis open signal circuits X701:9 E 1
shut off FGK and MVE
check cable/plugs for breaks, replace Relaismodul
942114 Engine uppercarr. DA, flame type heater plugs diagnosis short circuit to supply voltage X701:9 E 1
error report
check cable/plugs for UB-shorts, replace Relaismodul
942602 Engine uppercarr. oil pressure sensor sensor defect high/short circ. to supply voltage X703:1/2/3 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor
942603 Engine uppercarr. oil pressure sensor sensor defect low/short circuit to ground X703:1/2/3 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor
942702 Engine uppercarr. charge air pressure sensor sensor defect high/short circ. to supply voltage X703:4/5/6 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor
942703 Engine uppercarr. charge air pressure sensor sensor defect low/short circuit to ground X703:4/5/6 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor
942802 Engine uppercarr. air filter sensor sensor defect high/short circ. to supply voltage X703:7/8/9 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor
942803 Engine uppercarr. air filter sensor sensor defect low/short circuit to ground X703:7/8/9 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor
943102 Engine uppercarr. charge air temperature sensor sensor defect high/short circ. to supply voltage X703:12/15 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor
070645 404
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
943103 Engine uppercarr. charge air temperature sensor sensor defect low/short circuit to ground X703:12/15 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor
943202 Engine uppercarr. coolant temperature sensor sensor defect high/short circ. to supply voltage X703:10/11 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor
943203 Engine uppercarr. coolant temperature sensor sensor defect low/short circuit to ground X703:10/11 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor
943313 Engine uppercarr. coolant level sensor open signal circuits X704:10/11 E 1
signal ignored, substitute value used
check cable/plugs for defects or breaks, replace sensor
943402 Engine uppercarr. oil temperature sensor sensor defect high/short circ. to supply voltage X703:16/17 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor
943403 Engine uppercarr. oil temperature sensor sensor defect low/short circuit to ground X703:16/17 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor
943601 Engine uppercarr. trigger flame type heater plug(s) FGK unit defect X701:4 E 1
shut off FGK and MVE
943614 Engine uppercarr. trigger flame type heater plug(s) FGK short circuit to supply voltage X701:4 E 1
943615 Engine uppercarr. trigger flame type heater plug(s) FGK open electric circuit X701:4 E 1
error report
check cable/plugs for breaks, replace Relaismodul
943618 Engine uppercarr. trigger flame type heater plug(s) FGK excess temperature X701:4 E 1
shut off FGK and MVE
check cable/plugs for short to ground, replace Relaismodul
070645 405
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
943714 Engine uppercarr. solenoid valve additional flow for starting short circuit to supply voltage X701:6 E 1
943715 Engine uppercarr. solenoid valve additional flow for starting open electric circuit X701:6 E 1
FSA data defective, FGK activation removed, MVE reset: automatic after error counter sequence, after regulator reset
943718 Engine uppercarr. solenoid valve additional flow for starting excess temperature X701:6 E 1
shut off FGK and MVE
check cable/plugs for short to ground, replace Relaismodul
943814 Engine uppercarr. engine start 50A short circuit to supply voltage X701:5 E 1
943815 Engine uppercarr. engine start 50A open electric circuit X701:5 E 1
starting procedure interrupted, shut down FGK and MVE
check cable/plugs for breaks, replace Relaismodul
070645 406
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
946124 Engine uppercarr. charge air temperature pre-warning disruption limit 1 X703:12/15 E 1
warning, engine-protection-info, output reduction
reduce output, check air suction routing and engine
946125 Engine uppercarr. charge air temperature pre-warning disruption limit 2 X703:12/15 E 1
warning, engine-protection-info, output reduction
reduce output, if necessary shut off engine, check air suction routing and engine
946522 Engine uppercarr. air filter pressure pre-warning disruption limit 1 X703:7/8/9 E 1
pre-warning
replace air filter at next opportunity
946525 Engine uppercarr. air filter pressure pre-warning disruption limit 2 X703:7/8/9 E 1
warning
replace air filter immediately
070645 407
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
946824 Engine uppercarr. charge air pressure pre-warning disruption limit 1 X703:4/5/6 E 1
signal ignored, substitute value will be used, error report
check air suction routing
946825 Engine uppercarr. charge air pressure pre-warning disruption limit 2 X703:4/5/6 E 1
signal ignored, substitute value will be used, error report
check air suction routing
948250 Engine uppercarr. change engine oil filter service report interval 1 attained/exceeded X70 E 1
report
check and return
948350 Engine uppercarr. change engine oil service report interval 1 attained/exceeded X70 E 1
report
change oil and return
948351 Engine uppercarr. change engine oil service report interval 2 attained/exceeded X70 E 1
report
change oil and return
070645 408
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
948352 Engine uppercarr. change engine oil service report interval 3 attained/exceeded X70 E 1
report
change oil and return
948353 Engine uppercarr. change engine oil service report interval 4 attained/exceeded X70 E 1
report
change oil and return
948354 Engine uppercarr. change engine oil service report interval 5 attained/exceeded X70 E 1
report
change oil and return
948355 Engine uppercarr. change engine oil service report interval 6 attained/exceeded X70 E 1
report
change oil and return
948356 Engine uppercarr. change engine oil service report interval 7 attained/exceeded X70 E 1
report
change oil and return
948357 Engine uppercarr. change engine oil service report interval 8 attained/exceeded X70 E 1
report
change oil and return
948358 Engine uppercarr. change engine oil service report interval 9 attained/exceeded X70 E 1
report
change oil and return
948359 Engine uppercarr. change engine oil service report interval 10 attained/exceeded X70 E 1
report
change oil and return
948650 Engine uppercarr. check battery service report interval 1 attained/exceeded X70 E 1
report
check and return
948750 Engine uppercarr. change water filter service report interval 1 attained/exceeded X70 E 1
report
change filter and return
070645 409
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
948850 Engine uppercarr. check antifreeze service report interval 1 attained/exceeded X70 E 1
report
check and return
948950 Engine uppercarr. fuel filter level 1 service report interval 1 attained/exceeded X70 E 1
report
change filter and return
949150 Engine uppercarr. valve clearance service report interval 1 attained/exceeded X70 E 1
report
check and return
949250 Engine uppercarr. fuel injection valves service report interval 1 attained/exceeded X70 E 1
report
check and return
949450 Engine uppercarr. Exhaust gas recirculation (AGR) service report interval 1 attained/exceeded X70 E 1
report
change filter and return
971020 gear ASTRONIC: Main cut-off valve Y10 short circuit to ground E 1
Travel: Switching blocked - condition: Clutch opens, neutral switching blocked - automatic blocked
RESET - otherwise replace gear adjuster, ZF 10
971021 gear ASTRONIC: Main cut-off valve Y10 short circuit to supply voltage E 1
Switching blocked
RESET - otherwise replace gear adjuster, ZF 74
971120 gear ASTRONIC: Solenoid valve Y1 gear brake short circuit to ground E 1
Increased switch times - sporadic upshift locking - automatic blocked
RESET - otherwise replace gear adjuster, ZF 17
070645 410
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
971121 gear ASTRONIC: Solenoid valve Y1 gear brake short circuit to supply voltage E 1
Switching blocked
RESET - otherwise replace gear adjuster, ZF 81
971221 gear ASTRONIC: Solenoid valve Y2 splitter short circuit to supply voltage E 1
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 66
971321 gear ASTRONIC: Solenoid valve Y3 splitter short circuit to supply voltage E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 67
971421 gear ASTRONIC: Solenoid valve Y4 gap short circuit to supply voltage E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 68
070645 411
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
971521 gear ASTRONIC: Solenoid valve Y5 gap short circuit to supply voltage E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 69
971621 gear ASTRONIC: Solenoid valve Y6 switching short circuit to supply voltage E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 70
971721 gear ASTRONIC: Solenoid valve Y7 switching short circuit to supply voltage E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 71
070645 412
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
971821 gear ASTRONIC: Solenoid valve Y8 group short circuit to supply voltage E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 72
971921 gear ASTRONIC: Solenoid valve Y9 group short circuit to supply voltage E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 73
070645 413
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
070645 414
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
070645 415
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
070645 416
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
973520 gear ASTRONIC: Sensor gear input speed 1 short circuit to ground X45:6/11/18 E 1
Travel: Switching blocked - Automatic blocked
RESET- otherwise replace sensor, cable harness or gear adjuster, ZF 22
973521 gear ASTRONIC: Sensor gear input speed 1 short circuit to supply voltage X45:6/11/18 E 1
No function limitation - Automatic blocked
RESET- otherwise replace sensor, cable harness or gear adjuster, ZF 86
973542 gear ASTRONIC: Sensor gear input speed 1 faulty/not present X45:6/11/18 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - otherwise replace cable harness or speed sensor, ZF 99
973642 gear ASTRONIC: Gear output rpm 2,travel speed CAN faulty/not present E 1
No function limitation
RESET - check tacho system, ZF 100
973742 gear ASTRONIC: Sensor gear input speed 1/2 faulty/not present E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - check speed sensor 1 and 2, ZF 101
070645 417
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
974020 gear ASTRONIC: Solenoid valve Y15 "Clutch closes slowly" short circuit to ground X45:7 E 1
Increased switch times - sporadic upshift locking - automatic blocked
RESET - otherwise replace gear adjuster, ZF 19
974021 gear ASTRONIC: Solenoid valve Y15 "Clutch closes slowly" short circuit to supply voltage X45:7 E 2
Switching blocked - clutch function limited - condition: Neutral switching - system not available
RESET - otherwise replace cable harness coupling adjuster or coupling adjuster, ZF 83
974022 gear ASTRONIC: Solenoid valve Y15 "Clutch closes slowly" interruption X45:7 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - otherwise replace cable harness coupling adjuster or coupling adjuster, ZF 51
974033 gear ASTRONIC: Solenoid valve Y15 "Clutch closes slowly" Mechanical error X45:7 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - otherwise replace coupling adjuster, ZF 122
974120 gear ASTRONIC: Solenoid valve Y14 "Clutch closes quickly" short circuit to ground X45:8 E 1
Increased switch times - sporadic upshift locking - automatic blocked
RESET - otherwise replace gear adjuster, ZF 21
974121 gear ASTRONIC: Solenoid valve Y14 "Clutch closes quickly" short circuit to supply voltage X45:8 E 2
Switching blocked - clutch function limited - condition: Neutral switching - system not available
RESET - otherwise replace cable harness coupling adjuster or coupling adjuster, ZF 85
974122 gear ASTRONIC: Solenoid valve Y14 "Clutch closes quickly" interruption X45:8 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - otherwise replace cable harness coupling adjuster or coupling adjuster, ZF 53
974133 gear ASTRONIC: Solenoid valve Y14 "Clutch closes quickly" Mechanical error X45:8 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - otherwise replace coupling adjuster, ZF 123
974220 gear ASTRONIC: Solenoid valve Y17 "Clutch opens slowly" short circuit to ground X45:9 E 1
Increased switch times - sporadic upshift locking - automatic blocked
RESET - otherwise replace gear adjuster, ZF 18
070645 418
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
974221 gear ASTRONIC: Solenoid valve Y17 "Clutch opens slowly" short circuit to supply voltage X45:9 E 2
Switching blocked - clutch function limited - condition: Neutral switching - system not available
RESET - otherwise replace cable harness coupling adjuster or coupling adjuster, ZF 82
974222 gear ASTRONIC: Solenoid valve Y17 "Clutch opens slowly" interruption X45:9 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - otherwise replace cable harness coupling adjuster or coupling adjuster, ZF 50
974233 gear ASTRONIC: Solenoid valve Y17 "Clutch opens slowly" Mechanical error X45:9 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - otherwise replace coupling adjuster, ZF 120
974320 gear ASTRONIC: Solenoid valve Y16 "Clutch opens quickly" short circuit to ground X45:12 E 1
Increased switch times - sporadic upshift locking - automatic blocked
RESET - otherwise replace gear adjuster, ZF 20
974321 gear ASTRONIC: Solenoid valve Y16 "Clutch opens quickly" short circuit to supply voltage X45:12 E 2
Switching blocked - clutch function limited - condition: Neutral switching - system not available
RESET - otherwise replace cable harness coupling adjuster or coupling adjuster, ZF 84
974322 gear ASTRONIC: Solenoid valve Y16 "Clutch opens quickly" interruption X45:12 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - otherwise replace cable harness coupling adjuster or coupling adjuster, ZF 52
974333 gear ASTRONIC: Solenoid valve Y16 "Clutch opens quickly" Mechanical error X45:12 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - otherwise replace coupling adjuster, ZF 121
974424 gear ASTRONIC: Sensor clutch voltage below required value X45:10/15 E 1
Travel: Reduced comfort when travelling, no ranging, automatic time-controlled neutral switching, automatically blocked
RESET - Replace gear adjuster or coupling adjuster, ZF 107
070645 419
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
975421 gear ASTRONIC: TCU power supply short circuit to supply voltage X44:1/4/5 E 1
No function limitation
RESET - otherwise replace sensor or cables or gear adjuster, ZF 86
070645 420
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
976401 gear ASTRONIC: CAN-interface system Permanent error, Bus communication interrupted X44:8/12 E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - check cables of CAN communication, ZF 177
976404 gear ASTRONIC: CAN-interface system Memory error (queue overrun) X44:8/12 E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - check cables of CAN communication, ZF 179
976501 gear ASTRONIC: CAN-interface ZF Permanent error, Bus communication interrupted X44:8/12 E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - check cables of CAN communication, ZF 188
976503 gear ASTRONIC: CAN-interface ZF Faulty/missing, max. cycle time exceeded X44:8/12 E 1
Travel: Switching blocked - condition: automat. Engagement of last start-up gear - reverse gear blocked
RESET - otherwise replace gear adjuster, ZF 110
976611 gear ASTRONIC: Internal error TCU Memory error (stack watch) 4 E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - load software again - otherwise replace gear adjuster, ZF 189
976613 gear ASTRONIC: Internal error TCU EEPROM parameter check sum 4 E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - Enter EOL parameter check sum again, ZF 191
070645 421
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
976703 gear ASTRONIC: CAN-data transfer ABS/ASR (ID 512) Faulty/missing, max. cycle time exceeded X44:8/12 E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - check CAN-communication ECU - ABS, ZF 216
976803 gear ASTRONIC: CAN-data transfer ABS/ASR (ID 513) Faulty/missing, max. cycle time exceeded X44:8/12 E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - check CAN-communication ECU - ABS, ZF 217
976903 gear ASTRONIC: CAN-data transfer E/A-module (ID 588) Faulty/missing, max. cycle time exceeded X44:8/12 E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - check CAN-communication ECU - EA-module, ZF 230
977003 gear ASTRONIC: CAN-data transfer engine (ID 592) Faulty/missing, max. cycle time exceeded X44:8/12 E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - check CAN-communication ECU - MOT, ZF 218
977103 gear ASTRONIC: CAN-data transfer engine (ID 593) Faulty/missing, max. cycle time exceeded X44:8/12 E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - check CAN-communication ECU - MOT, ZF 219
977203 gear ASTRONIC: CAN-data transfer retarder (ID 772) Faulty/missing, max. cycle time exceeded X44:8/12 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - check CAN-communication ECU - INT, ZF 220
977603 gear ASTRONIC: CAN-data transfer Intarder (12xx) Faulty/missing, max. cycle time exceeded X44:8/12 E 1
Loss of comfort during start-up, switching and ranging
RESET - check CAN-communication ECU - INT, ZF 225
977703 gear ASTRONIC: CAN-data transfer engine (ID 1360) Faulty/missing, max. cycle time exceeded X44:8/12 E 2
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - check CAN-communication ECU - MOT, ZF 223
070645 422
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
978142 gear ASTRONIC: CAN-signal average speed front axle faulty/not present X44:8/12 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - check CAN-communication ECU - ABS, ZF 197
978242 gear ASTRONIC: CAN-signal differential speed front axle faulty/not present X44:8/12 E 1
No function limitation
RESET - check CAN-communication ECU - ABS, ZF 198
978342 gear ASTRONIC: CAN-signal intarder actual moment faulty/not present X44:8/12 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - check CAN-communication ECU - INT, ZF 28
978502 gear ASTRONIC: CAN-signal Telma actual moment Signal on CAN faulty/not present X44:8/12 E 1
No function limitation
RESET - check CAN-communication ECU - EA-module, ZF 229
979140 gear ASTRONIC: CAN-signal drive moment Soll Communication faulty/not present X44:8/12 E 1
Travel: Gear switching blocked - condition: Start-up gears can be switched - automatic blocked
RESET - check CAN-communication ECU - MOT, ZF 163
979242 gear ASTRONIC: CAN-signal drive moment Ist faulty/not present X44:8/12 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - check CAN-communication ECU - MOT, ZF 171
979342 gear ASTRONIC: CAN-signal engine moment dynamic faulty/not present X44:8/12 E 1
No function limitation
RESET - check CAN-communication ECU - MOT, ZF 167
070645 423
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
979442 gear ASTRONIC: CAN-signal engine break moment faulty/not present X44:8/12 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - check CAN-communication ECU - MOT, ZF 31
070645 424
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
981912 WSK: Outlet proportional valve retarder short circuit to supply voltage E 1
WSK-ECU no longer controls the prop.-valve; (line permanently active; if no earth shut-down path - permanent brake)
Check cables, prop.-valve; replace WSK-ECU, ZF 11
982111 WSK: Outlet earth switching proportional valve retarder short circuit to ground E 1
WSK-ECU shuts down the retarder; retarder no longer available. (line permanently active)
Check cables, prop.-valve; replace WSK-ECU, ZF 14
982112 WSK: Outlet earth switching proportional valve retarder short circuit to supply voltage E 1
WSK-ECU shuts down the retarder; retarder no longer available
Check cables, prop.-valve; replace WSK-ECU, ZF 15
982212 WSK: Outlet earth switching WK-valve short circuit to supply voltage E 1
WSK-ECU no longer controls outlet (WK-valve), only converter operation possible (depending on status output WK-valve)
Check cables, WK-valve (inner resistance approx. 120 Ohm; measure the WSK-ECU at the plug); replace WSK-ECU, ZF 17
070645 425
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
982316 WSK: Current sensing proportional valve retarder Permissible signal range fallen short of E 1
WSK-ECU shuts down the retarder; retarder no longer available
Replace WSK-ECU, ZF 24
982317 WSK: Current sensing proportional valve retarder Permissible signal range exceeded E 1
WSK-ECU shuts down the retarder; retarder no longer available
Replace WSK-ECU, ZF 25
070645 426
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
Replace WSK-ECU, ZF 35
070645 427