Lec 070645

Download as pdf or txt
Download as pdf or txt
You are on page 1of 429

LICCON Error Code Manual

LTM-1250-6.1
070645
21.03.2014

LIEBHERR-WERK EHINGEN GMBH, Postfach 1361, D-89582 Ehingen/Donau


Tel 0049 7391 502-0, Fax 0049 7391 502-3399
www.liebherr.com, E-Mail: info.lwe@liebherr.com
LICCON ERROR CODE (LEC)

Reference Identification number Illustration number

Electrics Superstructure 2 4096

Electrics Carrier /tmp/zfile 28.12.2004

Error list -515405 9131-700.00.00.000.012


Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

000001 ZE 0: system error OS-HC11 (observe parameters) initialising error processor-register erroneous E 2
no crane operation possible
if error re-occurs, then ZE should be replaced

000002 ZE 0: system error OS-HC11 (observe parameters) initialising error test total in EPROM/FLASH erroneous E 2
no crane operation possible
check program memory card or ZE

000006 ZE 0: system error OS-HC11 (observe parameters) initialising error RAM erroneous E 2
no crane operation possible
if error re-occurs, then ZE should be replaced

000007 ZE 0: system error OS-HC11 (observe parameters) UART erroneous E 2


no crane operation possible
if error re-occurs, then ZE should be replaced

000010 ZE 0: system error OS-HC11 (observe parameters) system routine inaccessible E 2


entry in error memory, all crane movements will be stopped

000011 ZE 0: system error OS-HC11 (observe parameters) ZE-watchdog expired E 2


entry in error memory, all crane movements will be stopped
check ZE

000012 ZE 0: system error OS-HC11 (observe parameters) type-identification in EPROM erroneous E 2


entry in error memory, no crane operation possible
check program memory card

000013 ZE 0: system error OS-HC11 (observe parameters) Test sum in FLASH erroneous E 2
entry in error memory, all crane movements will be stopped
check program memory card

000014 ZE 0: system error OS-HC11 (observe parameters) program already running E 2


entry in error memory, all crane movements will be stopped

000015 ZE 0: system error OS-HC11 (observe parameters) program not available E 2


entry in error memory, all crane movements will be stopped

070645 1
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

000016 ZE 0: system error OS-HC11 (observe parameters) system-, driver-watchdog expired E 2


entry in error memory, all crane movements will be stopped

000017 ZE 0: system error OS-HC11 (observe parameters) total of CPU-time distribution too great E 2
entry in error memory, all crane movements will be stopped

000018 ZE 0: system error OS-HC11 (observe parameters) arithmetic overflow (16 Bit) E 2
entry in error memory, all crane movements will be stopped

000019 ZE 0: system error OS-HC11 (observe parameters) division through zero (16 Bit) E 2
entry in error memory, all crane movements will be stopped

000020 ZE 0: system error OS-HC11 (observe parameters) task-watchdog expired E 2


entry in error memory, all crane movements will be stopped

000021 ZE 0: system error OS-HC11 (observe parameters) illegal opcode trap E 2


entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

000022 ZE 0: system error OS-HC11 (observe parameters) task inactive E 2


entry in error memory, all crane movements will be stopped

000023 ZE 0: system error OS-HC11 (observe parameters) program incapable of running (type identification) E 2
entry in error memory, all crane movements will be stopped

000024 ZE 0: system error OS-HC11 (observe parameters) task already used E 2


entry in error memory, all crane movements will be stopped

000025 ZE 0: system error OS-HC11 (observe parameters) realtime-module already used E 2


entry in error memory, all crane movements will be stopped

070645 2
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

000026 ZE 0: system error OS-HC11 (observe parameters) regulator-module already used E 2


entry in error memory, all crane movements will be stopped

000030 ZE 0: system error OS-HC11 (observe parameters) unacceptable bank address E 2


entry in error memory, all crane movements will be stopped

000041 ZE 0: system error OS-HC11 (observe parameters) arithmetic error E 2


entry in error memory, all crane movements will be stopped

000044 ZE 0: system error OS-HC11 (observe parameters) output parameter without effect, from inactive output E 2
entry in error memory, all crane movements will be stopped

000045 ZE 0: system error OS-HC11 (observe parameters) entry parameter undefined, from inactive input E 2
entry in error memory, all crane movements will be stopped

000046 ZE 0: system error OS-HC11 (observe parameters) impermissible regulator parameter E 2


entry in error memory, all crane movements will be stopped

000047 ZE 0: system error OS-HC11 (observe parameters) realtime-control block not available E 2
entry in error memory, all crane movements will be stopped

000048 ZE 0: system error OS-HC11 (observe parameters) realtime-control block inactive E 2


entry in error memory, all crane movements will be stopped

000049 ZE 0: system error OS-HC11 (observe parameters) urgent modul, ZE not available E 2
entry in error memory, no crane operation possible
check ZE

000050 ZE 0: system error OS-HC11 (observe parameters) file not available E 2


entry in error memory, all crane movements will be stopped

070645 3
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

000051 ZE 0: system error OS-HC11 (observe parameters) file already opened E 2


entry in error memory, all crane movements will be stopped

000052 ZE 0: system error OS-HC11 (observe parameters) file not open on close E 2
entry in error memory, all crane movements will be stopped

000053 ZE 0: system error OS-HC11 (observe parameters) system mask not available E 2
entry in error memory, all crane movements will be stopped

000054 ZE 0: system error OS-HC11 (observe parameters) system text not available E 2
entry in error memory, all crane movements will be stopped

000055 ZE 0: system error OS-HC11 (observe parameters) symbol not available E 2


entry in error memory, all crane movements will be stopped

000056 ZE 0: system error OS-HC11 (observe parameters) invalid mark in symbol E 2


entry in error memory, all crane movements will be stopped

000057 ZE 0: system error OS-HC11 (observe parameters) default load chart missing E 2
entry in error memory, all crane movements will be stopped

000058 ZE 0: system error OS-HC11 (observe parameters) amplifier erroneous or return power feed E 2
entry in error memory, all crane movements will be stopped
check wiring

000059 ZE 0: system error OS-HC11 (observe parameters) subroutine not reenterant E 2


entry in error memory, all crane movements will be stopped

000060 ZE 0: system error OS-HC11 (observe parameters) transmission error SCI E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

070645 4
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

000061 ZE 0: system error OS-HC11 (observe parameters) SCI-BREAK E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

000062 ZE 0: system error OS-HC11 (observe parameters) SCI not connected E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

000063 ZE 0: system error OS-HC11 (observe parameters) monitor error in operation E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

000065 ZE 0: system error OS-HC11 (observe parameters) impermissible bus address E 2


entry in error memory, all crane movements will be stopped

000066 ZE 0: system error OS-HC11 (observe parameters) ADC working outside the permissible tolerance E 2
entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

000067 ZE 0: system error OS-HC11 (observe parameters) arithmetic processor not available E 2
entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

000068 ZE 0: system error OS-HC11 (observe parameters) impermissible interrupt E 2


entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

000070 ZE 0: system error OS-HC11 (observe parameters) various structure versions E 2


entry in error memory, no crane operation possible

000071 ZE 0: system error OS-HC11 (observe parameters) Structure file missing or faulty E 2
entry in error memory, no crane operation possible

000072 ZE 0: system error OS-HC11 (observe parameters) structure entry senseless E 2


entry in error memory, no crane operation possible

070645 5
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

000073 ZE 0: system error OS-HC11 (observe parameters) interpreter error E 2


entry in error memory, all crane movements will be stopped

000074 ZE 0: system error OS-HC11 (observe parameters) transformation ASCII to BIN erroneous E 2
entry in error memory, all crane movements will be stopped

000075 ZE 0: system error OS-HC11 (observe parameters) SPI-error E 2


entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

000076 ZE 0: system error OS-HC11 (observe parameters) incorrectly inserted power unit E 2
entry in error memory, all crane movements will be stopped
check memory card in power supply unit

000077 ZE 0: system error OS-HC11 (observe parameters) BAF-call-up erroneous E 2


entry in error memory, all crane movements will be stopped

000078 ZE 0: system error OS-HC11 (observe parameters) impermissible parameter E 2


entry in error memory, all crane movements will be stopped

000079 ZE 0: system error OS-HC11 (observe parameters) no right of access E 2


entry in error memory, all crane movements will be stopped

000080 ZE 0: system error OS-HC11 (observe parameters) Fatal internal error E 2


entry in error memory, all crane movements will be stopped

000081 ZE 0: system error OS-HC11 (observe parameters) stack overflow E 2


entry in error memory, all crane movements will be stopped

000082 ZE 0: system error OS-HC11 (observe parameters) hardware-watchdog erroneous E 2


entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

070645 6
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

000094 ZE 0: system error OS-HC11 (observe parameters) transmission error parallel bus E 2
entry in error memory, all crane movements will be stopped
check ZE, bus circuit board, power supply unit

000095 ZE 0: system error OS-HC11 (observe parameters) DMA-error E 2


entry in error memory, all crane movements will be stopped
check ZE, bus circuit board, power supply unit

000099 ZE 0: system error OS-HC11 (observe parameters) DSP0 erroneous E 2


entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

002001 ZE 0: system error OS-TMS initialising error processor-register erroneous E 2


entry of error in error memory, all crane movements will be stopped
replace ZE

002002 ZE 0: system error OS-TMS initialising error test total in EPROM/FLASH erroneous E 2
entry of error in error memory, all crane movements will be stopped
replace ZE

002006 ZE 0: system error OS-TMS initialising error RAM erroneous E 2


entry of error in error memory, all crane movements will be stopped
replace ZE

002007 ZE 0: system error OS-TMS UART erroneous E 2


entry of error in error memory, all crane movements will be stopped
replace ZE

002020 ZE 0: system error OS-TMS task-watchdog expired E 2


entry of error in error memory, all crane movements will be stopped
elimination only possible through after-sales service

002021 ZE 0: system error OS-TMS illegal opcode trap E 2


entry of error in error memory, all crane movements will be stopped
elimination only possible through after-sales service

002082 ZE 0: system error OS-TMS hardware-watchdog erroneous E 2


entry of error in error memory, all crane movements will be stopped
elimination only possible through after-sales service

070645 7
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

010012 ZE 0: output 0 short circuit to ground X70:16 E 1

010013 ZE 0: output 0 open signal circuits X70:16 E 1

010014 ZE 0: output 0 short circuit to supply voltage X70:16 E 1

010054 ZE 0: output 0 short circuit to supply voltage X70:16 E 1

010058 ZE 0: output 0 positive switching transistor: disruption X70:16 E 1

010070 ZE 0: output 0 measuring system defect X70:16 E 1


no crane operation possible entry in error list

010071 ZE 0: output 0 short circuit to ground or transistor defect X70:16 E 1

010072 ZE 0: output 0 outside source feeding X70:16 E 1

010073 ZE 0: output 0 open circuit or short circuit to supply voltage/ground X70:16 E 1

010112 ZE 0: output 1 short circuit to ground X70:17 E 1

070645 8
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

010113 ZE 0: output 1 open signal circuits X70:17 E 1

010114 ZE 0: output 1 short circuit to supply voltage X70:17 E 1

010154 ZE 0: output 1 short circuit to supply voltage X70:17 E 1

010158 ZE 0: output 1 positive switching transistor: disruption X70:17 E 1

010170 ZE 0: output 1 measuring system defect X70:17 E 1


no crane operation possible entry in error list

010171 ZE 0: output 1 short circuit to ground or transistor defect X70:17 E 1

010172 ZE 0: output 1 outside source feeding X70:17 E 1

010173 ZE 0: output 1 open circuit or short circuit to supply voltage/ground X70:17 E 1

010212 ZE 0: output 2 short circuit to ground X70:18 E 1

010213 ZE 0: output 2 open signal circuits X70:18 E 1

070645 9
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

010214 ZE 0: output 2 short circuit to supply voltage X70:18 E 1

010254 ZE 0: output 2 short circuit to supply voltage X70:18 E 1

010258 ZE 0: output 2 positive switching transistor: disruption X70:18 E 1

010260 ZE 0: output 2 safety chain error, diode defect or safety contact sticking X70:18 E 1
report of error, otherwise no reaction
checking of safety contact and diode

010270 ZE 0: output 2 measuring system defect X70:18 E 1


no crane operation possible entry in error list

010271 ZE 0: output 2 short circuit to ground or transistor defect X70:18 E 1

010272 ZE 0: output 2 outside source feeding X70:18 E 1

010273 ZE 0: output 2 open circuit or short circuit to supply voltage/ground X70:18 E 1

010312 ZE 0: output 3 short circuit to ground X70:19 E 1

010313 ZE 0: output 3 open signal circuits X70:19 E 1

070645 10
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

010314 ZE 0: output 3 short circuit to supply voltage X70:19 E 1

010354 ZE 0: output 3 short circuit to supply voltage X70:19 E 1

010358 ZE 0: output 3 positive switching transistor: disruption X70:19 E 1

010370 ZE 0: output 3 measuring system defect X70:19 E 1


no crane operation possible entry in error list

010371 ZE 0: output 3 short circuit to ground or transistor defect X70:19 E 1

010372 ZE 0: output 3 outside source feeding X70:19 E 1

010373 ZE 0: output 3 open circuit or short circuit to supply voltage/ground X70:19 E 1

010412 ZE 0: output 4 short circuit to ground X70:20 E 1

010413 ZE 0: output 4 open signal circuits X70:20 E 1

010414 ZE 0: output 4 short circuit to supply voltage X70:20 E 1

070645 11
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

010454 ZE 0: output 4 short circuit to supply voltage X70:20 E 1

010458 ZE 0: output 4 positive switching transistor: disruption X70:20 E 1

010460 ZE 0: output 4 safety chain error, diode defect or safety contact sticking X70:20 E 1
report of error, otherwise no reaction
checking of safety contact and diode

010470 ZE 0: output 4 measuring system defect X70:20 E 1


no crane operation possible entry in error list

010471 ZE 0: output 4 short circuit to ground or transistor defect X70:20 E 1

010472 ZE 0: output 4 outside source feeding X70:20 E 1

010473 ZE 0: output 4 open circuit or short circuit to supply voltage/ground X70:20 E 1

010512 ZE 0: output 5 short circuit to ground X70:21 E 1

010513 ZE 0: output 5 open signal circuits X70:21 E 1

010514 ZE 0: output 5 short circuit to supply voltage X70:21 E 1

070645 12
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

010554 ZE 0: output 5 short circuit to supply voltage X70:21 E 1

010558 ZE 0: output 5 positive switching transistor: disruption X70:21 E 1

010560 ZE 0: output 5 safety chain error, diode defect or safety contact sticking X70:21 E 1
report of error, otherwise no reaction
checking of safety contact and diode

010570 ZE 0: output 5 measuring system defect X70:21 E 1


no crane operation possible entry in error list

010571 ZE 0: output 5 short circuit to ground or transistor defect X70:21 E 1

010572 ZE 0: output 5 outside source feeding X70:21 E 1

010573 ZE 0: output 5 open circuit or short circuit to supply voltage/ground X70:21 E 1

010612 ZE 0: output 6 short circuit to ground X70:22 E 1

010613 ZE 0: output 6 open signal circuits X70:22 E 1

010614 ZE 0: output 6 short circuit to supply voltage X70:22 E 1

070645 13
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

010654 ZE 0: output 6 short circuit to supply voltage X70:22 E 1

010658 ZE 0: output 6 positive switching transistor: disruption X70:22 E 1

010660 ZE 0: output 6 safety chain error, diode defect or safety contact sticking X70:22 E 1
report of error, otherwise no reaction
checking of safety contact and diode

010670 ZE 0: output 6 measuring system defect X70:22 E 1


no crane operation possible entry in error list

010671 ZE 0: output 6 short circuit to ground or transistor defect X70:22 E 1

010672 ZE 0: output 6 outside source feeding X70:22 E 1

010673 ZE 0: output 6 open circuit or short circuit to supply voltage/ground X70:22 E 1

010712 ZE 0: output 7 short circuit to ground X70:23 E 1

010713 ZE 0: output 7 open signal circuits X70:23 E 1

010714 ZE 0: output 7 short circuit to supply voltage X70:23 E 1

070645 14
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

010754 ZE 0: output 7 short circuit to supply voltage X70:23 E 1

010758 ZE 0: output 7 positive switching transistor: disruption X70:23 E 1

010760 ZE 0: output 7 safety chain error, diode defect or safety contact sticking X70:23 E 1
report of error, otherwise no reaction
checking of safety contact and diode

010770 ZE 0: output 7 measuring system defect X70:23 E 1


no crane operation possible entry in error list

010771 ZE 0: output 7 short circuit to ground or transistor defect X70:23 E 1

010772 ZE 0: output 7 outside source feeding X70:23 E 1

010773 ZE 0: output 7 open circuit or short circuit to supply voltage/ground X70:23 E 1

014959 ZE 0: all output supply voltage missing X70 E 1

015059 ZE 0: output group 0 supply voltage missing X70:12 E 1

015159 ZE 0: output group 1 supply voltage missing X70:24 E 1

070645 15
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

015259 ZE 0: output group 2 supply voltage missing X70:25 E 1

015359 ZE 0: output group 3 supply voltage missing X70:13 E 1

020004 ZE 0: LSB participant address 0 level exceeded X635:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

020005 ZE 0: LSB participant address 0 below minimum level X635:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

020018 ZE 0: LSB participant address 0 excess temperature X635:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

020050 ZE 0: LSB participant address 0 reports an incorrect sensor type X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

020051 ZE 0: LSB participant address 0 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

020053 ZE 0: LSB participant address 0 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

020054 ZE 0: LSB participant address 0 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

020064 ZE 0: LSB participant address 0 reports tolerable error in self-test X635:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

070645 16
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

020065 ZE 0: LSB participant address 0 reports intolerable error in self-test X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

020066 ZE 0: LSB participant address 0 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

020067 ZE 0: LSB participant address 0 supports no download function X635:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

020104 ZE 0: LSB participant address 1 level exceeded X635:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

020105 ZE 0: LSB participant address 1 below minimum level X635:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

020118 ZE 0: LSB participant address 1 excess temperature X635:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

020150 ZE 0: LSB participant address 1 reports an incorrect sensor type X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

020151 ZE 0: LSB participant address 1 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

020153 ZE 0: LSB participant address 1 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

020154 ZE 0: LSB participant address 1 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

070645 17
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

020164 ZE 0: LSB participant address 1 reports tolerable error in self-test X635:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

020165 ZE 0: LSB participant address 1 reports intolerable error in self-test X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

020166 ZE 0: LSB participant address 1 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

020167 ZE 0: LSB participant address 1 supports no download function X635:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

020204 ZE 0: LSB participant address 2 level exceeded X635:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

020205 ZE 0: LSB participant address 2 below minimum level X635:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

020218 ZE 0: LSB participant address 2 excess temperature X635:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

020250 ZE 0: LSB participant address 2 reports an incorrect sensor type X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

020251 ZE 0: LSB participant address 2 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

020253 ZE 0: LSB participant address 2 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

070645 18
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

020254 ZE 0: LSB participant address 2 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

020264 ZE 0: LSB participant address 2 reports tolerable error in self-test X635:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

020265 ZE 0: LSB participant address 2 reports intolerable error in self-test X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

020266 ZE 0: LSB participant address 2 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

020267 ZE 0: LSB participant address 2 supports no download function X635:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

020304 ZE 0: LSB participant address 3 level exceeded X635:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

020305 ZE 0: LSB participant address 3 below minimum level X635:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

020318 ZE 0: LSB participant address 3 excess temperature X635:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

020350 ZE 0: LSB participant address 3 reports an incorrect sensor type X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

020351 ZE 0: LSB participant address 3 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

070645 19
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

020353 ZE 0: LSB participant address 3 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

020354 ZE 0: LSB participant address 3 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

020364 ZE 0: LSB participant address 3 reports tolerable error in self-test X635:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

020365 ZE 0: LSB participant address 3 reports intolerable error in self-test X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

020366 ZE 0: LSB participant address 3 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

020367 ZE 0: LSB participant address 3 supports no download function X635:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

020404 ZE 0: LSB participant address 4 level exceeded X635:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

020405 ZE 0: LSB participant address 4 below minimum level X635:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

020418 ZE 0: LSB participant address 4 excess temperature X635:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

020450 ZE 0: LSB participant address 4 reports an incorrect sensor type X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

070645 20
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

020451 ZE 0: LSB participant address 4 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

020453 ZE 0: LSB participant address 4 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

020454 ZE 0: LSB participant address 4 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

020464 ZE 0: LSB participant address 4 reports tolerable error in self-test X635:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

020465 ZE 0: LSB participant address 4 reports intolerable error in self-test X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

020466 ZE 0: LSB participant address 4 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

020467 ZE 0: LSB participant address 4 supports no download function X635:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

020504 ZE 0: LSB participant address 5 level exceeded X635:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

020505 ZE 0: LSB participant address 5 below minimum level X635:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

020518 ZE 0: LSB participant address 5 excess temperature X635:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

070645 21
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

020550 ZE 0: LSB participant address 5 reports an incorrect sensor type X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

020551 ZE 0: LSB participant address 5 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

020553 ZE 0: LSB participant address 5 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

020554 ZE 0: LSB participant address 5 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

020564 ZE 0: LSB participant address 5 reports tolerable error in self-test X635:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

020565 ZE 0: LSB participant address 5 reports intolerable error in self-test X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

020566 ZE 0: LSB participant address 5 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

020567 ZE 0: LSB participant address 5 supports no download function X635:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

020604 ZE 0: LSB participant address 6 level exceeded X635:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

020605 ZE 0: LSB participant address 6 below minimum level X635:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

070645 22
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

020618 ZE 0: LSB participant address 6 excess temperature X635:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

020650 ZE 0: LSB participant address 6 reports an incorrect sensor type X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

020651 ZE 0: LSB participant address 6 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

020653 ZE 0: LSB participant address 6 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

020654 ZE 0: LSB participant address 6 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

020664 ZE 0: LSB participant address 6 reports tolerable error in self-test X635:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

020665 ZE 0: LSB participant address 6 reports intolerable error in self-test X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

020666 ZE 0: LSB participant address 6 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

020667 ZE 0: LSB participant address 6 supports no download function X635:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

021104 ZE 0: LSB participant address 11 level exceeded X635:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

070645 23
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

021105 ZE 0: LSB participant address 11 below minimum level X635:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

021118 ZE 0: LSB participant address 11 excess temperature X635:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

021150 ZE 0: LSB participant address 11 reports an incorrect sensor type X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

021151 ZE 0: LSB participant address 11 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

021153 ZE 0: LSB participant address 11 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

021154 ZE 0: LSB participant address 11 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

021164 ZE 0: LSB participant address 11 reports tolerable error in self-test X635:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

021165 ZE 0: LSB participant address 11 reports intolerable error in self-test X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

021166 ZE 0: LSB participant address 11 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

021167 ZE 0: LSB participant address 11 supports no download function X635:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

070645 24
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

021204 ZE 0: LSB participant address 12 level exceeded X635:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

021205 ZE 0: LSB participant address 12 below minimum level X635:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

021218 ZE 0: LSB participant address 12 excess temperature X635:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

021250 ZE 0: LSB participant address 12 reports an incorrect sensor type X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

021251 ZE 0: LSB participant address 12 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

021253 ZE 0: LSB participant address 12 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

021254 ZE 0: LSB participant address 12 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

021264 ZE 0: LSB participant address 12 reports tolerable error in self-test X635:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

021265 ZE 0: LSB participant address 12 reports intolerable error in self-test X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

021266 ZE 0: LSB participant address 12 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

070645 25
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

021267 ZE 0: LSB participant address 12 supports no download function X635:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

021304 ZE 0: LSB participant address 13 level exceeded X635:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

021305 ZE 0: LSB participant address 13 below minimum level X635:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

021318 ZE 0: LSB participant address 13 excess temperature X635:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

021350 ZE 0: LSB participant address 13 reports an incorrect sensor type X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

021351 ZE 0: LSB participant address 13 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

021353 ZE 0: LSB participant address 13 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

021354 ZE 0: LSB participant address 13 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

021364 ZE 0: LSB participant address 13 reports tolerable error in self-test X635:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

021365 ZE 0: LSB participant address 13 reports intolerable error in self-test X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

070645 26
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

021366 ZE 0: LSB participant address 13 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

021367 ZE 0: LSB participant address 13 supports no download function X635:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

021404 ZE 0: LSB participant address 14 level exceeded X635:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

021405 ZE 0: LSB participant address 14 below minimum level X635:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

021418 ZE 0: LSB participant address 14 excess temperature X635:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

021450 ZE 0: LSB participant address 14 reports an incorrect sensor type X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

021451 ZE 0: LSB participant address 14 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

021453 ZE 0: LSB participant address 14 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

021454 ZE 0: LSB participant address 14 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

021464 ZE 0: LSB participant address 14 reports tolerable error in self-test X635:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

070645 27
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

021465 ZE 0: LSB participant address 14 reports intolerable error in self-test X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

021466 ZE 0: LSB participant address 14 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

021467 ZE 0: LSB participant address 14 supports no download function X635:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

021504 ZE 0: LSB participant address 15 level exceeded X635:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

021505 ZE 0: LSB participant address 15 below minimum level X635:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

021518 ZE 0: LSB participant address 15 excess temperature X635:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

021550 ZE 0: LSB participant address 15 reports an incorrect sensor type X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

021551 ZE 0: LSB participant address 15 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

021553 ZE 0: LSB participant address 15 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

021554 ZE 0: LSB participant address 15 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

070645 28
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

021564 ZE 0: LSB participant address 15 reports tolerable error in self-test X635:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

021565 ZE 0: LSB participant address 15 reports intolerable error in self-test X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

021566 ZE 0: LSB participant address 15 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

021567 ZE 0: LSB participant address 15 supports no download function X635:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

022104 ZE 0: LSB participant address 21 level exceeded X635:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

022105 ZE 0: LSB participant address 21 below minimum level X635:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

022118 ZE 0: LSB participant address 21 excess temperature X635:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

022150 ZE 0: LSB participant address 21 reports an incorrect sensor type X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

022151 ZE 0: LSB participant address 21 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

022153 ZE 0: LSB participant address 21 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

070645 29
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

022154 ZE 0: LSB participant address 21 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

022164 ZE 0: LSB participant address 21 reports tolerable error in self-test X635:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

022165 ZE 0: LSB participant address 21 reports intolerable error in self-test X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

022166 ZE 0: LSB participant address 21 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

022167 ZE 0: LSB participant address 21 supports no download function X635:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

022204 ZE 0: LSB participant address 22 level exceeded X635:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

022205 ZE 0: LSB participant address 22 below minimum level X635:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

022218 ZE 0: LSB participant address 22 excess temperature X635:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

022250 ZE 0: LSB participant address 22 reports an incorrect sensor type X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

022251 ZE 0: LSB participant address 22 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

070645 30
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

022253 ZE 0: LSB participant address 22 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

022254 ZE 0: LSB participant address 22 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

022264 ZE 0: LSB participant address 22 reports tolerable error in self-test X635:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

022265 ZE 0: LSB participant address 22 reports intolerable error in self-test X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

022266 ZE 0: LSB participant address 22 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

022267 ZE 0: LSB participant address 22 supports no download function X635:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

022304 ZE 0: LSB participant address 23 level exceeded X635:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

022305 ZE 0: LSB participant address 23 below minimum level X635:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

022318 ZE 0: LSB participant address 23 excess temperature X635:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

022350 ZE 0: LSB participant address 23 reports an incorrect sensor type X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

070645 31
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

022351 ZE 0: LSB participant address 23 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

022353 ZE 0: LSB participant address 23 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

022354 ZE 0: LSB participant address 23 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

022364 ZE 0: LSB participant address 23 reports tolerable error in self-test X635:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

022365 ZE 0: LSB participant address 23 reports intolerable error in self-test X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

022366 ZE 0: LSB participant address 23 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

022367 ZE 0: LSB participant address 23 supports no download function X635:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

022404 ZE 0: LSB participant address 24 level exceeded X635:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

022405 ZE 0: LSB participant address 24 below minimum level X635:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

022418 ZE 0: LSB participant address 24 excess temperature X635:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

070645 32
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

022450 ZE 0: LSB participant address 24 reports an incorrect sensor type X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

022451 ZE 0: LSB participant address 24 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

022453 ZE 0: LSB participant address 24 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

022454 ZE 0: LSB participant address 24 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

022464 ZE 0: LSB participant address 24 reports tolerable error in self-test X635:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

022465 ZE 0: LSB participant address 24 reports intolerable error in self-test X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

022466 ZE 0: LSB participant address 24 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

022467 ZE 0: LSB participant address 24 supports no download function X635:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

022504 ZE 0: LSB participant address 25 level exceeded X635:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

022505 ZE 0: LSB participant address 25 below minimum level X635:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

070645 33
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

022518 ZE 0: LSB participant address 25 excess temperature X635:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

022550 ZE 0: LSB participant address 25 reports an incorrect sensor type X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

022551 ZE 0: LSB participant address 25 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

022553 ZE 0: LSB participant address 25 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

022554 ZE 0: LSB participant address 25 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

022564 ZE 0: LSB participant address 25 reports tolerable error in self-test X635:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

022565 ZE 0: LSB participant address 25 reports intolerable error in self-test X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

022566 ZE 0: LSB participant address 25 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

022567 ZE 0: LSB participant address 25 supports no download function X635:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

022804 ZE 0: LSB participant address 28 level exceeded X635:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

070645 34
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

022805 ZE 0: LSB participant address 28 below minimum level X635:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

022818 ZE 0: LSB participant address 28 excess temperature X635:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

022850 ZE 0: LSB participant address 28 reports an incorrect sensor type X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

022851 ZE 0: LSB participant address 28 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

022853 ZE 0: LSB participant address 28 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

022854 ZE 0: LSB participant address 28 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

022864 ZE 0: LSB participant address 28 reports tolerable error in self-test X635:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

022865 ZE 0: LSB participant address 28 reports intolerable error in self-test X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

022866 ZE 0: LSB participant address 28 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

022867 ZE 0: LSB participant address 28 supports no download function X635:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

070645 35
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

022904 ZE 0: LSB participant address 29 level exceeded X635:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

022905 ZE 0: LSB participant address 29 below minimum level X635:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

022918 ZE 0: LSB participant address 29 excess temperature X635:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

022950 ZE 0: LSB participant address 29 reports an incorrect sensor type X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

022951 ZE 0: LSB participant address 29 was not configured for the block transfer X635:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

022953 ZE 0: LSB participant address 29 no longer reports or withdrawn during running period X635:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

022954 ZE 0: LSB participant address 29 Features other settings (parameters) as pre-entered set values X635:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

022964 ZE 0: LSB participant address 29 reports tolerable error in self-test X635:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

022965 ZE 0: LSB participant address 29 reports intolerable error in self-test X635:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

022966 ZE 0: LSB participant address 29 with software version, that is no longer compatible X635:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

070645 36
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

022967 ZE 0: LSB participant address 29 supports no download function X635:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

023252 ZE 0: Control data transfer LSB has recognised Bus collisions, communication interrupted X635:z14/z16 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor

023255 ZE 0: Control data transfer LSB Bus connection faulty/defect, short circuit to supply voltage X635:z14/z16 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

023256 ZE 0: Control data transfer LSB Bus connection faulty/defect, no supply/short circuit to earth X635:z14/z16 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

023257 ZE 0: Control data transfer LSB has recognised network re-set (data transfer starts again) X635:z14/z16 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part

023258 ZE 0: Control data transfer LSB recognised participant with incorrect baud rate in bus X635:z14/z16 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors

023259 ZE 0: Control data transfer LSB recognised communication breakdown in bus X635:z14/z16 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network

023260 ZE 0: Control data transfer LSB driver error: no order to carry out X635:z14/z16 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software

023261 ZE 0: Control data transfer LSB driver error: undefined message appears X635:z14/z16 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination

023262 ZE 0: Control data transfer LSB Driver error: Initialization error X635:z14/z16 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination

070645 37
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

027210 ZE 0: input 24 inadmissable signal difference X635:b18 E 1


Output of error, due to defective feedback signal slewing platform locking no selection of corresponding table poss.
check supply, LICCON input, sensor lines to short or break, sensor

027602 ZE 0: input 28 sensor deficiency data short circuit to supply voltage X635:b26 E 1
report of error, otherwise no reaction
check supply, LICCON input, sensor lines to short or break, sensor

027610 ZE 0: input 28 inadmissable signal difference X635:b26 E 1


Output of error, due to defective feedback signal slewing platform locking no selection of corresponding table poss.
check supply, LICCON input, sensor lines to short or break, sensor

027702 ZE 0: input 29 sensor deficiency data short circuit to supply voltage X635:b28 E 1
report of error, otherwise no reaction
check supply, LICCON input, sensor lines to short or break, sensor

030000 ZE 0: LMB crane not commissioned or memory error B 1


error report only
program commissioning data according to commissioning report through after-sales service

030002 ZE 0: LMB minimum pressure in fly jib retaining cylinder below minimum B 1
error report only
check pressure sensor for fly jib retaining cylinder and replace if necessary

030003 ZE 0: LMB maximum pressure in fly jib retaining cylinder exceeded B 1


error report only
check pressure sensor of fly jib retaining cylinder and replace if necessary or check fly jib ret. cyl. for leaks

030005 ZE 0: LMB winch 1 not regulated, hook course indicator erroneous E 1


imprecise winch control and incorrect hook course indication for winch 1
trigger adjustment switch for hook course indication of winch 1 through lowering

030006 ZE 0: LMB winch 2 not regulated, hook course indicator erroneous E 1


imprecise winch control and incorrect hook course indication of winch 2
trigger adjustment switch for hook course indication of winch 2 through lowering

030007 ZE 0: LMB winch 3 not regulated, hook course indicator erroneous E 1


imprecise winch control and incorrect hook course indication of winch 3
trigger adjustment switch for hook course indication of winch 3 through lowering

070645 38
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

030040 ZE 0: LMB no standard table defined for this crane B 3


program stop
install new data memory card with corrected charts

030041 ZE 0: LMB all data for actual operation mode not available B 3
program stop
install new data memory card with corrected charts

030042 ZE 0: LMB no valid control word in this table B 3


program stop
install new data memory card with corrected charts

030050 ZE 0: LMB no load chart displayed B 1


acoustical signal on actuation of OK-key, no modification in operation program
select valid load chart through short-code or function keys F2-F6 and confirm with ENTER

030051 ZE 0: LMB external information (e.g. slewing platform bolting) missing B 1


load chart cannot be entered through OK-key
activate slewing platform lock, if necessary check connection to end of stroke switch, or select another load chart

030052 ZE 0: LMB re-fitting with load more than 0.5t and utilization larger 20% B 1
load chart cannot be entered through OK-key
put load to ground or switch crane off and on again

030053 ZE 0: LMB MAN-/AUTO-change-over blocked, unbolt cylinder/tele selected, MS B 1


switch-over on manual operation prevented as cylinder or tele not pinned
approach pre-selected telescoping target in automatic operation mode (bolt cylinder or tele)

030054 ZE 0: LMB no new telescoping objective, cylinder/tele unbolting selected, MS B 1


modification of telesc. objective prevented- cylinder/tele bolting switch not "0" set or MS "telescoping
switch over switch to "0" position and release MS "telescoping"

030059 ZE 0: LMB length sensor defect at bolting time, tele-length invalid B 1


actual tele length is rejected, LMB-Stop
retract boom completely and operate telescoping cylinder into last telescopic section

030064 ZE 0: LMB measured overall torque smaller than half torque without charge B 2
LMB-Stop: Load torque increasing movements cannot be affected
move boom out of danger zone or check sensor (angle-, pressure-, length),if load or radius indication incorrect

070645 39
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

030065 ZE 0: LMB computation-bound program part will no longer run B 2


LMB-Stop: Load torque increasing movements cannot be affected
on starting, the set-up equipment program key was pressed

030067 ZE 0: LMB STOP, difference between length sensors 1 and 2 too great B 2
LMB-Stop: Load torque increasing movements cannot be affected
set the correct length sensors zero point

030079 ZE 0: LMB STOP, adjusted op. mode and crane configuration not identical B 2
LMB-Stop: Load torque increasing movements cannot be affected
set up crane according to selected operation mode

030100 ZE 0: LMB STOP, main boom not mounted B 2


LMB-Stop: Load torque increasing movements cannot be affected
Mount missing assembly

030101 ZE 0: LMB STOP, jib not mounted B 2


LMB-Stop: Load torque increasing movements cannot be affected
Mount missing assembly

030110 ZE 0: LMB STOP, tipping danger at rear; no telescoping and no luffing B 2


load torque reducing movements (telescoping in, luffing up) cannot de affected
take care when luffing down to chart area while assembly mode selected

030120 ZE 0: LMB STOP, end of stroke switch 1 in tele-operation not connected B 2


LMB-Stop: Load torque increasing movements cannot be affected
connect end of stroke switch 1, or check limit switch or supply line

030121 ZE 0: LMB STOP, end of stroke switch 1 reports internal error E 2

Check hoist limit switch

030122 ZE 0: LMB STOP, end of stroke switch 2 in auxiliary boom op. not connected B 2
LMB-Stop: Load torque increasing movements cannot be affected
connect end of stroke switch 2, or check limit switch or supply line

030123 ZE 0: LMB STOP, end of stroke switch 2 reports internal error E 2

Check hoist limit switch

070645 40
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

030124 ZE 0: LMB STOP, end of stroke switch 3 in auxiliary boom op. not connected B 2
LMB-Stop: Load torque increasing movements cannot be affected
connect end of stroke switch 3, or check limit switch or supply line

030125 ZE 0: LMB STOP, end of stroke switch 3 reports internal error E 2

Check hoist limit switch

030130 ZE 0: LMB STOP, hoist limit switch 4 with 2 winch device not connected E 2
LMB-Stop: Load torque increasing movements cannot be affected
Connect hoist limit switch 4, or check limit switch supply line

030131 ZE 0: LMB STOP, hoist limit switch 4 reports internal error E 2


LMB-Stop: Load torque increasing movements cannot be affected
Check hoist limit switch

030135 ZE 0: LMB permissible deviation of data A/B tension meas. bracket 1 exceeded B 2
LMB-Stop: Load torque increasing movements cannot be affected
check tension connecting brackets or line, stress flow difference in both tension connecting brackets possible

030136 ZE 0: LMB permissible deviation of data A/B tension meas. bracket 2 exceeded B 2
LMB-Stop: Load torque increasing movements cannot be affected
check tension connecting brackets or line, stress flow difference in both tension connecting brackets possible

030137 ZE 0: LMB permissible deviation of data A/B tension meas. bracket 3 exceeded B 2
LMB-Stop: Load torque increasing movements cannot be affected
check tension connecting brackets or line, stress flow difference in both tension connecting brackets possible

030147 ZE 0: LMB working radius list in load chart with incorrect value B 2
LMB-Stop: Load torque increasing movements cannot be affected
install new data memory card with corrected charts

030148 ZE 0: LMB actual working radius too small, not in chart B 2


LMB-Stop: Load torque increasing movements cannot be affected
take care when luffing down to chart area while assembly mode selected

030149 ZE 0: LMB actual working radius too large, not in chart B 2


LMB-Stop: Load torque increasing movements cannot be affected
take care with "luffing up when overloaded" when luffing up into chart area

070645 41
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

030150 ZE 0: LMB crane stands in impermissible length-/angle position B 2


LMB-Stop: Load torque increasing movements cannot be affected
conduct boom in permissible position referred to length, boom angle, bolting condition and fly jib angle

030151 ZE 0: LMB unknown access type to load chart B 2


LMB-Stop: Load torque increasing movements cannot be affected
install new data memory card with corrected charts

030152 ZE 0: LMB no table exists for actual crane configuration B 2


LMB-Stop: Load torque increasing movements cannot be affected
purchase additional load charts, install new data memory card with corrected charts

030153 ZE 0: LMB selected attachment config. not corresponding with actual condition B 2
LMB-Stop: Load torque increasing movements cannot be affected
select load chart corresponding to actual crane configuration

030154 ZE 0: LMB crane improperly supported or support pressure sensor defect B 2


LMB-Stop: Increased load torque movements and slewing cannot be affected
support crane so that the wheels are lifted from ground or check support pressure sensor or its lines

030155 ZE 0: LMB selected ballast not corresponding with actual condition B 2


LMB-Stop: Increased load torque movements and slewing cannot be affected
select chart that corresponds to the applied counterweight

030156 ZE 0: LMB selected support not corresponding with actual condition B 2


LMB-Stop: Load torque increasing movements, selected chart cannot be entered
enter chart that corresponds to the actual support condition

030157 ZE 0: LMB selected slewing range not corresponding with actual condition B 2
LMB-Stop: Load torque increasing movements cannot be affected
enter chart that corresponds to the actual slewing range

030163 ZE 0: LMB left/right pressure sensors not the same E 2


LMB-Stop: Load torque increasing movements cannot be affected
check pressure sensor or its line

030165 ZE 0: LMB difference between upper/lower angle sensor tele too great B 2
LMB-Stop: Load torque increasing movements cannot be affected
retrieve crane deflection through unloading, or check both angle sensors or their lines

070645 42
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

030182 ZE 0: LMB difference between angle sensor cylinder lower/upper too great B 2
LMB-Stop: Load torque increasing movements cannot be affected
retrieve crane deflection through unloading, or check both angle sensors or their lines

030185 ZE 0: LMB actual ballast different from set ballast B 2


LMB-Stop: Load torque increasing movements cannot be affected
enter chart according to mounted counterweight

030186 ZE 0: LMB actual support different from support set B 2


LMB-Stop: Load torque increasing movements cannot be affected
enter chart according to adjusted support basis

030187 ZE 0: LMB actual slewing range different from set slewing range B 2
LMB-Stop: Load torque increasing movements cannot be affected
enter chart according to actual slewing angle of the boom

030190 ZE 0: LMB angle sensor error: load, reach, pulley head height indication defect E 2
LMB-Stop: Load torque increasing movements cannot be affected
check LSB-connection, angle sensor

030200 ZE 0: LMB STOP, crane correspondent table over-equipped B 2


control-Stop: even in operation mode crane movements cannot be affected
enter chart according to mounted equipment

030202 ZE 0: LMB All movements STOP, jib over-equipped B 2


control-Stop: even in operation mode crane movements cannot be affected
Disassemble surplus assemblies

030254 ZE 0: LMB STOP, miscalculation in interpolation (X1=X2) E 2


LMB-Stop: Load torque increasing movements cannot be affected
install new data memory card with corrected charts

033941 ZE 0: crane control Emergency operation switched on, Caution shut-downs ineffective B

034800 ZE 0: control diagnosis system slewing sensor defective/missing E 1


Carrying out of test program delayed / interrupted
Check rotary encoder and connection, carry out test program again

070645 43
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

034801 ZE 0: control diagnosis system tele angle sensor defective/missing E 1


Carrying out of test program delayed / interrupted
Check angle transmitter and connection, carry out test program again

034805 ZE 0: control diagnosis system longitudinal sensor defective/missing E 1


Carrying out of test program delayed / interrupted
Check length indicator and connection, carry out test program again

034825 ZE 0: control diagnosis system charge pressure in slewing gear defective/missing E 1


Carrying out of test program delayed / interrupted
Check pressure hoist gear, carry out test program again

034833 ZE 0: control diagnosis system Pressure cut-off swing gear outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check pressure hoist gear, carry out test program again

034856 ZE 0: control diagnosis system slewing gear turning with closed brakes E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

034857 ZE 0: control diagnosis system Initial current swing gear right above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

034858 ZE 0: control diagnosis system Initial current swing gear right below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

034859 ZE 0: control diagnosis system Initial current swing gear left above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

034860 ZE 0: control diagnosis system Initial current swing gear left below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

034861 ZE 0: control diagnosis system slewing speed right slewing gear too low E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

070645 44
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

034862 ZE 0: control diagnosis system slewing speed right slewing gear too high E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

034863 ZE 0: control diagnosis system slewing speed left slewing gear too low E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

034864 ZE 0: control diagnosis system slewing speed left slewing gear too high E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

034865 ZE 0: control diagnosis system Hysteresis right-hand swing gear too great
Carrying out of test program delayed / interrupted
Check proportional-flow valve

034866 ZE 0: control diagnosis system Hysteresis left-hand swing gear too great
Carrying out of test program delayed / interrupted
Check proportional-flow valve

035641 ZE 0: operation telescoping emergency op. telescope activated, caution switch-offs ineffective B

035808 ZE 0: operation slewing shut-down slewing right working area limitation ABB B
operational shut down
slew left until crane is in working area again - shunting through shut-down of working area limitation

035809 ZE 0: operation slewing shut-down slewing left working area limitation ABB B
operational shut down
slew right until crane is in working area again - shunting through shut-down of working area limitation

035810 ZE 0: operation slewing Shut-down free swing gear working area limitation ABB is active B

035811 ZE 0: operation slewing Shut off stop brake slewing gear working range limitation active B

070645 45
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

035812 ZE 0: operation slewing Shut off stop brake slewing gear slewing range limitation limit load B

035820 ZE 0: operation slewing shut-down slewing right LMB B


operational shut down
slew left until crane is within support area again - shut-down can be shunted (danger)

035821 ZE 0: operation slewing shut-down slewing left LMB B


operational shut down
slew right until crane is within support area again - shut-down can be shunted (danger)

035822 ZE 0: operation slewing Shut-down right-hand swing maximum load exceeded B


operational shut down
Turn left until crane once again within the immediate swing area

035823 ZE 0: operation slewing Shut-down left-hand swing maximum load exceeded B


operational shut down
Turn right until crane once again within the immediate swing area

035824 ZE 0: operation slewing Shut-down free swing gear swing area limitation load is on B

035828 ZE 0: operation slewing Shut off coasting slewing gear sliding arm monitor B

035829 ZE 0: operation slewing Shut off stop brake slewing gear sliding arm monitor B

035831 ZE 0: operation slewing Master switch 2 faulty/not present B


operational shut down
eliminate error see corresponding system error

035839 ZE 0: operation slewing seat contact shut-down B


operational shut down
Sit down or actuate one of the shunting switches for the seat contact in the master switches.

070645 46
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

035844 ZE 0: operation slewing Shut-off crane engine not running B


operational shut down
Start crane engine. For test purposes actuate bridging "without engine" (control ON without engine).

035850 ZE 0: operation slewing Shut-off N-change-over pulley folded B


operational shut down
Fold up N-change-over pulley

035851 ZE 0: operation slewing Recognition control winch 2 installed/N-pulley block erroneous/missing B


operational shut down
Check "Winch 2 mounted" and "N-adjusting block folded down", pins are inserted in winch frame but not in winch

035890 ZE 0: operation slewing Slewing platform not bolted or impermissible bolting condition B 1
report of error, otherwise no reaction
Correct bolting position, check position ok: -supply, -input LICCON, -sensor line for short-circuit, -sensor

037313 ZE 0: operation instruments armrest left master switch 2X not in neutral when starting B 1
output of error, shut-down through application
release master switch briefly or check LICCON input, gear lines, sensor

039800 ZE 0: operation diagnosis system interruption, master switch defective or incorrectly deflected B 1
Carrying out of test program delayed / interrupted
Note direction of movements, carry out test program again

039801 ZE 0: operation diagnosis system interruption, master switch defective/missing B 1


Carrying out of test program delayed / interrupted
Check master switch, carry out test program again

039802 ZE 0: operation diagnosis system interruption, incorrect or no operation mode B 1


Carrying out of test program delayed / interrupted
Set correct operation type, if necessary dismantle accessory, carry out test program again

039814 ZE 0: operation diagnosis system Alignment aid not correctly shut down B 1
Invalid operation condition, no proper crane operation possible
Apply F key, end active test program

039820 ZE 0: operation diagnosis system interruption, boom angle beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Extend to correct luffing position, carry out test program again

070645 47
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

039821 ZE 0: operation diagnosis system interruption, tele length beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Extend to correct telescopic boom length length, carry out test program again

039822 ZE 0: operation diagnosis system interruption, hook load beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Note max. hook load, carry out test program again

039824 ZE 0: operation diagnosis system interruption, end of stroke switch activated/defective/missing B 1


Carrying out of test program delayed / interrupted
Check hoist limit switch, carry out test program again

100001 ZE 1: system error OS-HC11 (observe parameters) initialising error processor-register erroneous E 2
no crane operation possible
if error re-occurs, then ZE should be replaced

100002 ZE 1: system error OS-HC11 (observe parameters) initialising error test total in EPROM/FLASH erroneous E 2
no crane operation possible
check program memory card or ZE

100006 ZE 1: system error OS-HC11 (observe parameters) initialising error RAM erroneous E 2
no crane operation possible
if error re-occurs, then ZE should be replaced

100007 ZE 1: system error OS-HC11 (observe parameters) UART erroneous E 2


no crane operation possible
if error re-occurs, then ZE should be replaced

100010 ZE 1: system error OS-HC11 (observe parameters) system routine inaccessible E 2


entry in error memory, all crane movements will be stopped

100011 ZE 1: system error OS-HC11 (observe parameters) ZE-watchdog expired E 2


entry in error memory, all crane movements will be stopped
check ZE

100012 ZE 1: system error OS-HC11 (observe parameters) type-identification in EPROM erroneous E 2


entry in error memory, no crane operation possible
check program memory card

070645 48
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

100013 ZE 1: system error OS-HC11 (observe parameters) Test sum in FLASH erroneous E 2
entry in error memory, all crane movements will be stopped
check program memory card

100014 ZE 1: system error OS-HC11 (observe parameters) program already running E 2


entry in error memory, all crane movements will be stopped

100015 ZE 1: system error OS-HC11 (observe parameters) program not available E 2


entry in error memory, all crane movements will be stopped

100016 ZE 1: system error OS-HC11 (observe parameters) system-, driver-watchdog expired E 2


entry in error memory, all crane movements will be stopped

100017 ZE 1: system error OS-HC11 (observe parameters) total of CPU-time distribution too great E 2
entry in error memory, all crane movements will be stopped

100018 ZE 1: system error OS-HC11 (observe parameters) arithmetic overflow (16 Bit) E 2
entry in error memory, all crane movements will be stopped

100019 ZE 1: system error OS-HC11 (observe parameters) division through zero (16 Bit) E 2
entry in error memory, all crane movements will be stopped

100020 ZE 1: system error OS-HC11 (observe parameters) task-watchdog expired E 2


entry in error memory, all crane movements will be stopped

100021 ZE 1: system error OS-HC11 (observe parameters) illegal opcode trap E 2


entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

100022 ZE 1: system error OS-HC11 (observe parameters) task inactive E 2


entry in error memory, all crane movements will be stopped

070645 49
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

100023 ZE 1: system error OS-HC11 (observe parameters) program incapable of running (type identification) E 2
entry in error memory, all crane movements will be stopped

100024 ZE 1: system error OS-HC11 (observe parameters) task already used E 2


entry in error memory, all crane movements will be stopped

100025 ZE 1: system error OS-HC11 (observe parameters) realtime-module already used E 2


entry in error memory, all crane movements will be stopped

100026 ZE 1: system error OS-HC11 (observe parameters) regulator-module already used E 2


entry in error memory, all crane movements will be stopped

100030 ZE 1: system error OS-HC11 (observe parameters) unacceptable bank address E 2


entry in error memory, all crane movements will be stopped

100041 ZE 1: system error OS-HC11 (observe parameters) arithmetic error E 2


entry in error memory, all crane movements will be stopped

100044 ZE 1: system error OS-HC11 (observe parameters) output parameter without effect, from inactive output E 2
entry in error memory, all crane movements will be stopped

100045 ZE 1: system error OS-HC11 (observe parameters) entry parameter undefined, from inactive input E 2
entry in error memory, all crane movements will be stopped

100046 ZE 1: system error OS-HC11 (observe parameters) impermissible regulator parameter E 2


entry in error memory, all crane movements will be stopped

100047 ZE 1: system error OS-HC11 (observe parameters) realtime-control block not available E 2
entry in error memory, all crane movements will be stopped

070645 50
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

100048 ZE 1: system error OS-HC11 (observe parameters) realtime-control block inactive E 2


entry in error memory, all crane movements will be stopped

100049 ZE 1: system error OS-HC11 (observe parameters) urgent modul, ZE not available E 2
entry in error memory, no crane operation possible
check ZE

100050 ZE 1: system error OS-HC11 (observe parameters) file not available E 2


entry in error memory, all crane movements will be stopped

100051 ZE 1: system error OS-HC11 (observe parameters) file already opened E 2


entry in error memory, all crane movements will be stopped

100052 ZE 1: system error OS-HC11 (observe parameters) file not open on close E 2
entry in error memory, all crane movements will be stopped

100053 ZE 1: system error OS-HC11 (observe parameters) system mask not available E 2
entry in error memory, all crane movements will be stopped

100054 ZE 1: system error OS-HC11 (observe parameters) system text not available E 2
entry in error memory, all crane movements will be stopped

100055 ZE 1: system error OS-HC11 (observe parameters) symbol not available E 2


entry in error memory, all crane movements will be stopped

100056 ZE 1: system error OS-HC11 (observe parameters) invalid mark in symbol E 2


entry in error memory, all crane movements will be stopped

100057 ZE 1: system error OS-HC11 (observe parameters) default load chart missing E 2
entry in error memory, all crane movements will be stopped

070645 51
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

100058 ZE 1: system error OS-HC11 (observe parameters) amplifier erroneous or return power feed E 2
entry in error memory, all crane movements will be stopped
check wiring

100059 ZE 1: system error OS-HC11 (observe parameters) subroutine not reenterant E 2


entry in error memory, all crane movements will be stopped

100060 ZE 1: system error OS-HC11 (observe parameters) transmission error SCI E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

100061 ZE 1: system error OS-HC11 (observe parameters) SCI-BREAK E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

100062 ZE 1: system error OS-HC11 (observe parameters) SCI not connected E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

100063 ZE 1: system error OS-HC11 (observe parameters) monitor error in operation E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

100065 ZE 1: system error OS-HC11 (observe parameters) impermissible bus address E 2


entry in error memory, all crane movements will be stopped

100066 ZE 1: system error OS-HC11 (observe parameters) ADC working outside the permissible tolerance E 2
entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

100067 ZE 1: system error OS-HC11 (observe parameters) arithmetic processor not available E 2
entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

100068 ZE 1: system error OS-HC11 (observe parameters) impermissible interrupt E 2


entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

070645 52
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

100070 ZE 1: system error OS-HC11 (observe parameters) various structure versions E 2


entry in error memory, no crane operation possible

100071 ZE 1: system error OS-HC11 (observe parameters) Structure file missing or faulty E 2
entry in error memory, no crane operation possible

100072 ZE 1: system error OS-HC11 (observe parameters) structure entry senseless E 2


entry in error memory, no crane operation possible

100073 ZE 1: system error OS-HC11 (observe parameters) interpreter error E 2


entry in error memory, all crane movements will be stopped

100074 ZE 1: system error OS-HC11 (observe parameters) transformation ASCII to BIN erroneous E 2
entry in error memory, all crane movements will be stopped

100075 ZE 1: system error OS-HC11 (observe parameters) SPI-error E 2


entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

100076 ZE 1: system error OS-HC11 (observe parameters) incorrectly inserted power unit E 2
entry in error memory, all crane movements will be stopped
check memory card in power supply unit

100077 ZE 1: system error OS-HC11 (observe parameters) BAF-call-up erroneous E 2


entry in error memory, all crane movements will be stopped

100078 ZE 1: system error OS-HC11 (observe parameters) impermissible parameter E 2


entry in error memory, all crane movements will be stopped

100079 ZE 1: system error OS-HC11 (observe parameters) no right of access E 2


entry in error memory, all crane movements will be stopped

070645 53
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

100080 ZE 1: system error OS-HC11 (observe parameters) Fatal internal error E 2


entry in error memory, all crane movements will be stopped

100081 ZE 1: system error OS-HC11 (observe parameters) stack overflow E 2


entry in error memory, all crane movements will be stopped

100082 ZE 1: system error OS-HC11 (observe parameters) hardware-watchdog erroneous E 2


entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

100094 ZE 1: system error OS-HC11 (observe parameters) transmission error parallel bus E 2
entry in error memory, all crane movements will be stopped
check ZE, bus circuit board, power supply unit

100095 ZE 1: system error OS-HC11 (observe parameters) DMA-error E 2


entry in error memory, all crane movements will be stopped
check ZE, bus circuit board, power supply unit

100099 ZE 1: system error OS-HC11 (observe parameters) DSP0 erroneous E 2


entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

102001 ZE 1: system error OS-TMS initialising error processor-register erroneous E 2


entry of error in error memory, all crane movements will be stopped
replace ZE

102002 ZE 1: system error OS-TMS initialising error test total in EPROM/FLASH erroneous E 2
entry of error in error memory, all crane movements will be stopped
replace ZE

102006 ZE 1: system error OS-TMS initialising error RAM erroneous E 2


entry of error in error memory, all crane movements will be stopped
replace ZE

102007 ZE 1: system error OS-TMS UART erroneous E 2


entry of error in error memory, all crane movements will be stopped
replace ZE

070645 54
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

102020 ZE 1: system error OS-TMS task-watchdog expired E 2


entry of error in error memory, all crane movements will be stopped
elimination only possible through after-sales service

102021 ZE 1: system error OS-TMS illegal opcode trap E 2


entry of error in error memory, all crane movements will be stopped
elimination only possible through after-sales service

102082 ZE 1: system error OS-TMS hardware-watchdog erroneous E 2


entry of error in error memory, all crane movements will be stopped
elimination only possible through after-sales service

110012 ZE 1: output 0 short circuit to ground X71:16 E 1

110013 ZE 1: output 0 open signal circuits X71:16 E 1

110014 ZE 1: output 0 short circuit to supply voltage X71:16 E 1

110054 ZE 1: output 0 short circuit to supply voltage X71:16 E 1

110058 ZE 1: output 0 positive switching transistor: disruption X71:16 E 1

110070 ZE 1: output 0 measuring system defect X71:16 E 1


no crane operation possible entry in error list

110071 ZE 1: output 0 short circuit to ground or transistor defect X71:16 E 1

070645 55
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

110072 ZE 1: output 0 outside source feeding X71:16 E 1

110073 ZE 1: output 0 open circuit or short circuit to supply voltage/ground X71:16 E 1

110112 ZE 1: output 1 short circuit to ground X71:17 E 1

110113 ZE 1: output 1 open signal circuits X71:17 E 1

110114 ZE 1: output 1 short circuit to supply voltage X71:17 E 1

110154 ZE 1: output 1 short circuit to supply voltage X71:17 E 1

110158 ZE 1: output 1 positive switching transistor: disruption X71:17 E 1

110170 ZE 1: output 1 measuring system defect X71:17 E 1


no crane operation possible entry in error list

110171 ZE 1: output 1 short circuit to ground or transistor defect X71:17 E 1

110172 ZE 1: output 1 outside source feeding X71:17 E 1

070645 56
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

110173 ZE 1: output 1 open circuit or short circuit to supply voltage/ground X71:17 E 1

110212 ZE 1: output 2 short circuit to ground X71:18 E 1

110213 ZE 1: output 2 open signal circuits X71:18 E 1

110214 ZE 1: output 2 short circuit to supply voltage X71:18 E 1

110254 ZE 1: output 2 short circuit to supply voltage X71:18 E 1

110258 ZE 1: output 2 positive switching transistor: disruption X71:18 E 1

110260 ZE 1: output 2 safety chain error, diode defect or safety contact sticking X71:18 E 1
report of error, otherwise no reaction
checking of safety contact and diode

110270 ZE 1: output 2 measuring system defect X71:18 E 1


no crane operation possible entry in error list

110271 ZE 1: output 2 short circuit to ground or transistor defect X71:18 E 1

110272 ZE 1: output 2 outside source feeding X71:18 E 1

070645 57
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

110273 ZE 1: output 2 open circuit or short circuit to supply voltage/ground X71:18 E 1

110312 ZE 1: output 3 short circuit to ground X71:19 E 1

110313 ZE 1: output 3 open signal circuits X71:19 E 1

110314 ZE 1: output 3 short circuit to supply voltage X71:19 E 1

110354 ZE 1: output 3 short circuit to supply voltage X71:19 E 1

110358 ZE 1: output 3 positive switching transistor: disruption X71:19 E 1

110360 ZE 1: output 3 safety chain error, diode defect or safety contact sticking X71:19 E 1
report of error, otherwise no reaction
checking of safety contact and diode

110370 ZE 1: output 3 measuring system defect X71:19 E 1


no crane operation possible entry in error list

110371 ZE 1: output 3 short circuit to ground or transistor defect X71:19 E 1

110372 ZE 1: output 3 outside source feeding X71:19 E 1

070645 58
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

110373 ZE 1: output 3 open circuit or short circuit to supply voltage/ground X71:19 E 1

110412 ZE 1: output 4 short circuit to ground X71:20 E 1

110413 ZE 1: output 4 open signal circuits X71:20 E 1

110414 ZE 1: output 4 short circuit to supply voltage X71:20 E 1

110454 ZE 1: output 4 short circuit to supply voltage X71:20 E 1

110458 ZE 1: output 4 positive switching transistor: disruption X71:20 E 1

110460 ZE 1: output 4 safety chain error, diode defect or safety contact sticking X71:20 E 1
report of error, otherwise no reaction
checking of safety contact and diode

110470 ZE 1: output 4 measuring system defect X71:20 E 1


no crane operation possible entry in error list

110471 ZE 1: output 4 short circuit to ground or transistor defect X71:20 E 1

110472 ZE 1: output 4 outside source feeding X71:20 E 1

070645 59
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

110473 ZE 1: output 4 open circuit or short circuit to supply voltage/ground X71:20 E 1

110512 ZE 1: output 5 short circuit to ground X71:21 E 1

110513 ZE 1: output 5 open signal circuits X71:21 E 1

110514 ZE 1: output 5 short circuit to supply voltage X71:21 E 1

110554 ZE 1: output 5 short circuit to supply voltage X71:21 E 1

110558 ZE 1: output 5 positive switching transistor: disruption X71:21 E 1

110560 ZE 1: output 5 safety chain error, diode defect or safety contact sticking X71:21 E 1
report of error, otherwise no reaction
checking of safety contact and diode

110570 ZE 1: output 5 measuring system defect X71:21 E 1


no crane operation possible entry in error list

110571 ZE 1: output 5 short circuit to ground or transistor defect X71:21 E 1

110572 ZE 1: output 5 outside source feeding X71:21 E 1

070645 60
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

110573 ZE 1: output 5 open circuit or short circuit to supply voltage/ground X71:21 E 1

110612 ZE 1: output 6 short circuit to ground X71:22 E 1

110613 ZE 1: output 6 open signal circuits X71:22 E 1

110614 ZE 1: output 6 short circuit to supply voltage X71:22 E 1

110654 ZE 1: output 6 short circuit to supply voltage X71:22 E 1

110658 ZE 1: output 6 positive switching transistor: disruption X71:22 E 1

110660 ZE 1: output 6 safety chain error, diode defect or safety contact sticking X71:22 E 1
report of error, otherwise no reaction
checking of safety contact and diode

110670 ZE 1: output 6 measuring system defect X71:22 E 1


no crane operation possible entry in error list

110671 ZE 1: output 6 short circuit to ground or transistor defect X71:22 E 1

110672 ZE 1: output 6 outside source feeding X71:22 E 1

070645 61
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

110673 ZE 1: output 6 open circuit or short circuit to supply voltage/ground X71:22 E 1

110712 ZE 1: output 7 short circuit to ground X71:23 E 1

110713 ZE 1: output 7 open signal circuits X71:23 E 1

110714 ZE 1: output 7 short circuit to supply voltage X71:23 E 1

110754 ZE 1: output 7 short circuit to supply voltage X71:23 E 1

110758 ZE 1: output 7 positive switching transistor: disruption X71:23 E 1

110760 ZE 1: output 7 safety chain error, diode defect or safety contact sticking X71:23 E 1
report of error, otherwise no reaction
checking of safety contact and diode

110770 ZE 1: output 7 measuring system defect X71:23 E 1


no crane operation possible entry in error list

110771 ZE 1: output 7 short circuit to ground or transistor defect X71:23 E 1

110772 ZE 1: output 7 outside source feeding X71:23 E 1

070645 62
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

110773 ZE 1: output 7 open circuit or short circuit to supply voltage/ground X71:23 E 1

114959 ZE 1: all output supply voltage missing X71 E 1

115059 ZE 1: output group 0 supply voltage missing X71:12 E 1

115159 ZE 1: output group 1 supply voltage missing X71:24 E 1

115259 ZE 1: output group 2 supply voltage missing X71:25 E 1

115359 ZE 1: output group 3 supply voltage missing X71:13 E 1

120004 ZE 1: LSB participant address 0 level exceeded X635A:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

120005 ZE 1: LSB participant address 0 below minimum level X635A:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

120018 ZE 1: LSB participant address 0 excess temperature X635A:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

120050 ZE 1: LSB participant address 0 reports an incorrect sensor type X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

070645 63
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

120051 ZE 1: LSB participant address 0 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

120053 ZE 1: LSB participant address 0 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

120054 ZE 1: LSB participant address 0 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

120064 ZE 1: LSB participant address 0 reports tolerable error in self-test X635A:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

120065 ZE 1: LSB participant address 0 reports intolerable error in self-test X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

120066 ZE 1: LSB participant address 0 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

120067 ZE 1: LSB participant address 0 supports no download function X635A:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

120104 ZE 1: LSB participant address 1 level exceeded X635A:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

120105 ZE 1: LSB participant address 1 below minimum level X635A:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

120118 ZE 1: LSB participant address 1 excess temperature X635A:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

070645 64
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

120150 ZE 1: LSB participant address 1 reports an incorrect sensor type X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

120151 ZE 1: LSB participant address 1 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

120153 ZE 1: LSB participant address 1 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

120154 ZE 1: LSB participant address 1 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

120164 ZE 1: LSB participant address 1 reports tolerable error in self-test X635A:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

120165 ZE 1: LSB participant address 1 reports intolerable error in self-test X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

120166 ZE 1: LSB participant address 1 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

120167 ZE 1: LSB participant address 1 supports no download function X635A:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

120804 ZE 1: LSB participant address 8 level exceeded X635A:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

120805 ZE 1: LSB participant address 8 below minimum level X635A:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

070645 65
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

120818 ZE 1: LSB participant address 8 excess temperature X635A:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

120850 ZE 1: LSB participant address 8 reports an incorrect sensor type X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

120851 ZE 1: LSB participant address 8 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

120853 ZE 1: LSB participant address 8 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

120854 ZE 1: LSB participant address 8 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

120864 ZE 1: LSB participant address 8 reports tolerable error in self-test X635A:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

120865 ZE 1: LSB participant address 8 reports intolerable error in self-test X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

120866 ZE 1: LSB participant address 8 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

120867 ZE 1: LSB participant address 8 supports no download function X635A:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

120904 ZE 1: LSB participant address 9 level exceeded X635A:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

070645 66
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

120905 ZE 1: LSB participant address 9 below minimum level X635A:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

120918 ZE 1: LSB participant address 9 excess temperature X635A:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

120950 ZE 1: LSB participant address 9 reports an incorrect sensor type X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

120951 ZE 1: LSB participant address 9 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

120953 ZE 1: LSB participant address 9 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

120954 ZE 1: LSB participant address 9 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

120964 ZE 1: LSB participant address 9 reports tolerable error in self-test X635A:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

120965 ZE 1: LSB participant address 9 reports intolerable error in self-test X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

120966 ZE 1: LSB participant address 9 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

120967 ZE 1: LSB participant address 9 supports no download function X635A:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

070645 67
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

121004 ZE 1: LSB participant address 10 level exceeded X635A:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

121005 ZE 1: LSB participant address 10 below minimum level X635A:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

121018 ZE 1: LSB participant address 10 excess temperature X635A:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

121050 ZE 1: LSB participant address 10 reports an incorrect sensor type X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

121051 ZE 1: LSB participant address 10 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

121053 ZE 1: LSB participant address 10 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

121054 ZE 1: LSB participant address 10 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

121064 ZE 1: LSB participant address 10 reports tolerable error in self-test X635A:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

121065 ZE 1: LSB participant address 10 reports intolerable error in self-test X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

121066 ZE 1: LSB participant address 10 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

070645 68
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

121067 ZE 1: LSB participant address 10 supports no download function X635A:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

121104 ZE 1: LSB participant address 11 level exceeded X635A:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

121105 ZE 1: LSB participant address 11 below minimum level X635A:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

121118 ZE 1: LSB participant address 11 excess temperature X635A:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

121150 ZE 1: LSB participant address 11 reports an incorrect sensor type X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

121151 ZE 1: LSB participant address 11 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

121153 ZE 1: LSB participant address 11 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

121154 ZE 1: LSB participant address 11 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

121164 ZE 1: LSB participant address 11 reports tolerable error in self-test X635A:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

121165 ZE 1: LSB participant address 11 reports intolerable error in self-test X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

070645 69
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

121166 ZE 1: LSB participant address 11 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

121167 ZE 1: LSB participant address 11 supports no download function X635A:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

121204 ZE 1: LSB participant address 12 level exceeded X635A:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

121205 ZE 1: LSB participant address 12 below minimum level X635A:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

121218 ZE 1: LSB participant address 12 excess temperature X635A:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

121250 ZE 1: LSB participant address 12 reports an incorrect sensor type X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

121251 ZE 1: LSB participant address 12 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

121253 ZE 1: LSB participant address 12 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

121254 ZE 1: LSB participant address 12 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

121264 ZE 1: LSB participant address 12 reports tolerable error in self-test X635A:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

070645 70
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

121265 ZE 1: LSB participant address 12 reports intolerable error in self-test X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

121266 ZE 1: LSB participant address 12 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

121267 ZE 1: LSB participant address 12 supports no download function X635A:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

121304 ZE 1: LSB participant address 13 level exceeded X635A:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

121305 ZE 1: LSB participant address 13 below minimum level X635A:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

121318 ZE 1: LSB participant address 13 excess temperature X635A:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

121350 ZE 1: LSB participant address 13 reports an incorrect sensor type X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

121351 ZE 1: LSB participant address 13 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

121353 ZE 1: LSB participant address 13 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

121354 ZE 1: LSB participant address 13 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

070645 71
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

121364 ZE 1: LSB participant address 13 reports tolerable error in self-test X635A:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

121365 ZE 1: LSB participant address 13 reports intolerable error in self-test X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

121366 ZE 1: LSB participant address 13 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

121367 ZE 1: LSB participant address 13 supports no download function X635A:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

121404 ZE 1: LSB participant address 14 level exceeded X635A:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

121405 ZE 1: LSB participant address 14 below minimum level X635A:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

121418 ZE 1: LSB participant address 14 excess temperature X635A:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

121450 ZE 1: LSB participant address 14 reports an incorrect sensor type X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

121451 ZE 1: LSB participant address 14 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

121453 ZE 1: LSB participant address 14 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

070645 72
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

121454 ZE 1: LSB participant address 14 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

121464 ZE 1: LSB participant address 14 reports tolerable error in self-test X635A:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

121465 ZE 1: LSB participant address 14 reports intolerable error in self-test X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

121466 ZE 1: LSB participant address 14 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

121467 ZE 1: LSB participant address 14 supports no download function X635A:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

121604 ZE 1: LSB participant address 16 level exceeded X635A:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

121605 ZE 1: LSB participant address 16 below minimum level X635A:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

121618 ZE 1: LSB participant address 16 excess temperature X635A:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

121650 ZE 1: LSB participant address 16 reports an incorrect sensor type X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

121651 ZE 1: LSB participant address 16 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

070645 73
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

121653 ZE 1: LSB participant address 16 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

121654 ZE 1: LSB participant address 16 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

121664 ZE 1: LSB participant address 16 reports tolerable error in self-test X635A:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

121665 ZE 1: LSB participant address 16 reports intolerable error in self-test X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

121666 ZE 1: LSB participant address 16 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

121667 ZE 1: LSB participant address 16 supports no download function X635A:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

121704 ZE 1: LSB participant address 17 level exceeded X635A:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

121705 ZE 1: LSB participant address 17 below minimum level X635A:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

121718 ZE 1: LSB participant address 17 excess temperature X635A:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

121750 ZE 1: LSB participant address 17 reports an incorrect sensor type X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

070645 74
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

121751 ZE 1: LSB participant address 17 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

121753 ZE 1: LSB participant address 17 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

121754 ZE 1: LSB participant address 17 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

121764 ZE 1: LSB participant address 17 reports tolerable error in self-test X635A:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

121765 ZE 1: LSB participant address 17 reports intolerable error in self-test X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

121766 ZE 1: LSB participant address 17 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

121767 ZE 1: LSB participant address 17 supports no download function X635A:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

121804 ZE 1: LSB participant address 18 level exceeded X635A:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

121805 ZE 1: LSB participant address 18 below minimum level X635A:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

121818 ZE 1: LSB participant address 18 excess temperature X635A:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

070645 75
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

121850 ZE 1: LSB participant address 18 reports an incorrect sensor type X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

121851 ZE 1: LSB participant address 18 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

121853 ZE 1: LSB participant address 18 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

121854 ZE 1: LSB participant address 18 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

121864 ZE 1: LSB participant address 18 reports tolerable error in self-test X635A:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

121865 ZE 1: LSB participant address 18 reports intolerable error in self-test X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

121866 ZE 1: LSB participant address 18 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

121867 ZE 1: LSB participant address 18 supports no download function X635A:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

121904 ZE 1: LSB participant address 19 level exceeded X635A:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

121905 ZE 1: LSB participant address 19 below minimum level X635A:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

070645 76
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

121918 ZE 1: LSB participant address 19 excess temperature X635A:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

121950 ZE 1: LSB participant address 19 reports an incorrect sensor type X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

121951 ZE 1: LSB participant address 19 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

121953 ZE 1: LSB participant address 19 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

121954 ZE 1: LSB participant address 19 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

121964 ZE 1: LSB participant address 19 reports tolerable error in self-test X635A:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

121965 ZE 1: LSB participant address 19 reports intolerable error in self-test X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

121966 ZE 1: LSB participant address 19 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

121967 ZE 1: LSB participant address 19 supports no download function X635A:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

122004 ZE 1: LSB participant address 20 level exceeded X635A:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

070645 77
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

122005 ZE 1: LSB participant address 20 below minimum level X635A:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

122018 ZE 1: LSB participant address 20 excess temperature X635A:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

122050 ZE 1: LSB participant address 20 reports an incorrect sensor type X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

122051 ZE 1: LSB participant address 20 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

122053 ZE 1: LSB participant address 20 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

122054 ZE 1: LSB participant address 20 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

122064 ZE 1: LSB participant address 20 reports tolerable error in self-test X635A:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

122065 ZE 1: LSB participant address 20 reports intolerable error in self-test X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

122066 ZE 1: LSB participant address 20 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

122067 ZE 1: LSB participant address 20 supports no download function X635A:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

070645 78
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

122104 ZE 1: LSB participant address 21 level exceeded X635A:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

122105 ZE 1: LSB participant address 21 below minimum level X635A:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

122118 ZE 1: LSB participant address 21 excess temperature X635A:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

122150 ZE 1: LSB participant address 21 reports an incorrect sensor type X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

122151 ZE 1: LSB participant address 21 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

122153 ZE 1: LSB participant address 21 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

122154 ZE 1: LSB participant address 21 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

122164 ZE 1: LSB participant address 21 reports tolerable error in self-test X635A:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

122165 ZE 1: LSB participant address 21 reports intolerable error in self-test X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

122166 ZE 1: LSB participant address 21 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

070645 79
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

122167 ZE 1: LSB participant address 21 supports no download function X635A:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

122204 ZE 1: LSB participant address 22 level exceeded X635A:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

122205 ZE 1: LSB participant address 22 below minimum level X635A:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

122218 ZE 1: LSB participant address 22 excess temperature X635A:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

122250 ZE 1: LSB participant address 22 reports an incorrect sensor type X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

122251 ZE 1: LSB participant address 22 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

122253 ZE 1: LSB participant address 22 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

122254 ZE 1: LSB participant address 22 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

122264 ZE 1: LSB participant address 22 reports tolerable error in self-test X635A:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

122265 ZE 1: LSB participant address 22 reports intolerable error in self-test X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

070645 80
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

122266 ZE 1: LSB participant address 22 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

122267 ZE 1: LSB participant address 22 supports no download function X635A:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

122304 ZE 1: LSB participant address 23 level exceeded X635A:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

122305 ZE 1: LSB participant address 23 below minimum level X635A:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

122318 ZE 1: LSB participant address 23 excess temperature X635A:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

122350 ZE 1: LSB participant address 23 reports an incorrect sensor type X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

122351 ZE 1: LSB participant address 23 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

122353 ZE 1: LSB participant address 23 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

122354 ZE 1: LSB participant address 23 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

122364 ZE 1: LSB participant address 23 reports tolerable error in self-test X635A:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

070645 81
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

122365 ZE 1: LSB participant address 23 reports intolerable error in self-test X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

122366 ZE 1: LSB participant address 23 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

122367 ZE 1: LSB participant address 23 supports no download function X635A:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

122504 ZE 1: LSB participant address 25 level exceeded X635A:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

122505 ZE 1: LSB participant address 25 below minimum level X635A:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

122518 ZE 1: LSB participant address 25 excess temperature X635A:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

122550 ZE 1: LSB participant address 25 reports an incorrect sensor type X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

122551 ZE 1: LSB participant address 25 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

122553 ZE 1: LSB participant address 25 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

122554 ZE 1: LSB participant address 25 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

070645 82
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

122564 ZE 1: LSB participant address 25 reports tolerable error in self-test X635A:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

122565 ZE 1: LSB participant address 25 reports intolerable error in self-test X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

122566 ZE 1: LSB participant address 25 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

122567 ZE 1: LSB participant address 25 supports no download function X635A:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

122604 ZE 1: LSB participant address 26 level exceeded X635A:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

122605 ZE 1: LSB participant address 26 below minimum level X635A:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

122618 ZE 1: LSB participant address 26 excess temperature X635A:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

122650 ZE 1: LSB participant address 26 reports an incorrect sensor type X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

122651 ZE 1: LSB participant address 26 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

122653 ZE 1: LSB participant address 26 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

070645 83
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

122654 ZE 1: LSB participant address 26 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

122664 ZE 1: LSB participant address 26 reports tolerable error in self-test X635A:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

122665 ZE 1: LSB participant address 26 reports intolerable error in self-test X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

122666 ZE 1: LSB participant address 26 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

122667 ZE 1: LSB participant address 26 supports no download function X635A:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

122904 ZE 1: LSB participant address 29 level exceeded X635A:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

122905 ZE 1: LSB participant address 29 below minimum level X635A:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

122918 ZE 1: LSB participant address 29 excess temperature X635A:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

122950 ZE 1: LSB participant address 29 reports an incorrect sensor type X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

122951 ZE 1: LSB participant address 29 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

070645 84
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

122953 ZE 1: LSB participant address 29 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

122954 ZE 1: LSB participant address 29 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

122964 ZE 1: LSB participant address 29 reports tolerable error in self-test X635A:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

122965 ZE 1: LSB participant address 29 reports intolerable error in self-test X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

122966 ZE 1: LSB participant address 29 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

122967 ZE 1: LSB participant address 29 supports no download function X635A:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

123004 ZE 1: LSB participant address 30 level exceeded X635A:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

123005 ZE 1: LSB participant address 30 below minimum level X635A:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

123018 ZE 1: LSB participant address 30 excess temperature X635A:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

123050 ZE 1: LSB participant address 30 reports an incorrect sensor type X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

070645 85
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

123051 ZE 1: LSB participant address 30 was not configured for the block transfer X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

123053 ZE 1: LSB participant address 30 no longer reports or withdrawn during running period X635A:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

123054 ZE 1: LSB participant address 30 Features other settings (parameters) as pre-entered set values X635A:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

123064 ZE 1: LSB participant address 30 reports tolerable error in self-test X635A:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

123065 ZE 1: LSB participant address 30 reports intolerable error in self-test X635A:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

123066 ZE 1: LSB participant address 30 with software version, that is no longer compatible X635A:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

123067 ZE 1: LSB participant address 30 supports no download function X635A:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

123252 ZE 1: Control data transfer LSB has recognised Bus collisions, communication interrupted X635A:z14/z16 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor

123255 ZE 1: Control data transfer LSB Bus connection faulty/defect, short circuit to supply voltage X635A:z14/z16 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

123256 ZE 1: Control data transfer LSB Bus connection faulty/defect, no supply/short circuit to earth X635A:z14/z16 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

070645 86
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

123257 ZE 1: Control data transfer LSB has recognised network re-set (data transfer starts again) X635A:z14/z16 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part

123258 ZE 1: Control data transfer LSB recognised participant with incorrect baud rate in bus X635A:z14/z16 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors

123259 ZE 1: Control data transfer LSB recognised communication breakdown in bus X635A:z14/z16 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network

123260 ZE 1: Control data transfer LSB driver error: no order to carry out X635A:z14/z16 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software

123261 ZE 1: Control data transfer LSB driver error: undefined message appears X635A:z14/z16 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination

123262 ZE 1: Control data transfer LSB Driver error: Initialization error X635A:z14/z16 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination

130570 ZE 1: remote control emergency operation telescoping movement selected with LICCON B 1

130571 ZE 1: remote control telescoping movement selected in manual operation B 1

130572 ZE 1: remote control selection with 2-winch operation mode E 1


error report, telescoping prevented
check SW-configuration, check LICCON input radio control

130610 ZE 1: Data recorder Start: (still) no valid crane number entered E 1


Inspect in 10 sec. cycles
Write in coefficients incl. crane number in the NT in "CRANE COMMISSIONING " program (MO > AK)

070645 87
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

130611 ZE 1: Data recorder Start: Crane number faulty (not 9 figures numerically) E 1
Data recorder software stops - no documentation possible!
Define crane number correctly (Sxxxxxxx.yyQ - KNFttt00vvrr.Q)

130620 ZE 1: Data recorder Init: Firmware version incorrect/faulty E 1


Has not yet been checked!

130621 ZE 1: Data recorder Init: ATA-card not initialised E 1


STATUS-error: Data recorder software stops - no documentation possible!
Initialise ATA card with PC-Software "LICCON Manager"

130622 ZE 1: Data recorder Init: ATA-card contains different crane number E 1


STATUS-error: Data recorder software stops - no documentation possible!
Use ATA card with correct crane number or newly initialised ATA card

130623 ZE 1: Data recorder Init: Format-File-Transfer faulty E 1


Repeat of Format-File transfers in 1 sec. cycles
If necessary correct types and country specific Format-File "Lnnttt01vvrr.Q" in EPROM 0

130630 ZE 1: Data recorder Transfer: Data transmission faulty E 1


Repeat of data transfers in 1 sec. cycles
If necessary check connection from LICCON system to data recorder

130631 ZE 1: Data recorder Transfer: CSM-protocol error E 1


Respective telegram is repeated max. 3x, then synchronise completely anew
If necessary check connection from LICCON system to data recorder

130632 ZE 1: Data recorder Transfer: Transmission error (CRC) E 1


Respective telegram is repeated max. 3x, then synchronise completely anew
If necessary check connection from LICCON system to data recorder

130633 ZE 1: Data recorder Transfer: STATUS-error E 1


Dependent upon STATUS in 1 sec. cycles synchronise anew or stop data recorder software
If necessary check connection from LICCON system to data recorder

130634 ZE 1: Data recorder Transfer: TAN-error E 1


Synchronise CSM protocol again completely
If necessary check connection from LICCON system to data recorder

070645 88
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

130635 ZE 1: Data recorder Transfer: Writing error E 1


Synchronise CSM protocol again completely
If necessary check connection from LICCON-System to data recorder and ATA card

130636 ZE 1: Data recorder Transfer: No recorder data (SPS-Handshake) E 1


LICCON-data logger software tries again in 1 sec. cycle
Check function of SPS software

132650 ZE 1: control telescoping Tele recognition faulty, more than one track switch reporting active B
Telescoping blocked, telestatus possibly tipped, possibly incorrect/no telescopic boom length length
Switched limit switch, check cylinder attachment

132680 ZE 1: control telescoping "Folding jib pivoted in" mounted, folding jib not mounted E

132681 ZE 1: control telescoping "Special auxiliary boom swung in" mounted, accessory not mounted E

134801 ZE 1: control diagnosis system tele angle sensor defective/missing E 1


Carrying out of test program delayed / interrupted
Check angle transmitter and connection, carry out test program again

134805 ZE 1: control diagnosis system longitudinal sensor defective/missing E 1


Carrying out of test program delayed / interrupted
Check length indicator and connection, carry out test program again

135604 ZE 1: operation telescoping Shut-off telescoping special auxiliary boom swung in B

135605 ZE 1: operation telescoping Shut-off telescoping folding jib swung in B

135607 ZE 1: operation telescoping lower angle limit UGW shut-down B

070645 89
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

135608 ZE 1: operation telescoping shut-down tele OUT main boom working area limitation ABB B

135609 ZE 1: operation telescoping shut-down tele IN main boom working area limitation ABB B

135610 ZE 1: operation telescoping fly jib upper stop shut-down B

135611 ZE 1: operation telescoping fly jib upper flap shut-down B

135613 ZE 1: operation telescoping shut-down as flap not positioned and angle threshold exceeded B

135614 ZE 1: operation telescoping pressure retaining cylinder RFP N shut-down outside set range B

135615 ZE 1: operation telescoping adjustable pulley-N on stop shut-down B

135616 ZE 1: operation telescoping shut-down extending accessory working area limitation ABB B

135617 ZE 1: operation telescoping shut-down retracting accessory working area limitation ABB B

135619 ZE 1: operation telescoping no or invalid operation mode shut-down B

070645 90
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

135620 ZE 1: operation telescoping LMB shut-down B

135621 ZE 1: operation telescoping shut-down release of extending LMB B

135622 ZE 1: operation telescoping shut-down tipping risk to rear B

135623 ZE 1: operation telescoping transport setting assembly unit-N shut-down B

135629 ZE 1: operation telescoping Shut off hose drum accessories not clear B
operational shut down

135630 ZE 1: operation telescoping master switch 1 defective/missing B

135631 ZE 1: operation telescoping master switch 2 defective/missing B

135635 ZE 1: operation telescoping right foot tipping switch defective/missing B

135639 ZE 1: operation telescoping seat contact shut-down B

135640 ZE 1: operation telescoping length measurement shut-down defective/missing B

070645 91
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

135643 ZE 1: operation telescoping Shut-down, luffing gear selected B

135644 ZE 1: operation telescoping Shut-off crane engine not running B

135649 ZE 1: operation telescoping Shut-down hoist limit switch 4 B

135650 ZE 1: operation telescoping end of stroke switch shut-down 1 B

135651 ZE 1: operation telescoping end of stroke switch shut-down 2 B

135652 ZE 1: operation telescoping end of stroke switch shut-down 3 B

135660 ZE 1: operation telescoping unbolting telescope not possible, cylinder is not bolted B

135661 ZE 1: operation telescoping unbolting telescope not possible, no LMB release B

135662 ZE 1: operation telescoping unbolting telescope/cylinder not possible, simultaneous selection B

135663 ZE 1: operation telescoping unbolting cylinder not possible, telescope is not bolted B

070645 92
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

135664 ZE 1: operation telescoping unbolting cylinder not possible, automatic system adjusted B

135665 ZE 1: operation telescoping unbolting telescope not possible, automatic system adjusted B

135670 ZE 1: operation telescoping shut-down both limit switches "flap in position" defect./missing B

135671 ZE 1: operation telescoping shut-down both limit switches "NA-boom 3 pos." defect./missing B

135672 ZE 1: operation telescoping shut-down both angle sensors "fly jib" defective/missing B

135673 ZE 1: operation telescoping shut-down both limit switches "lower fly jib" defective/missing B

135674 ZE 1: operation telescoping shut-down both limit switches "upper fly jib flap" defect./missing B

135675 ZE 1: operation telescoping shut-down both limit switches "upper fly jib stop"defect./missing B

135676 ZE 1: operation telescoping shut-down limit switch adjustable pulley-N defective/missing B

135681 ZE 1: operation telescoping end of stroke switch 1 shut-down defective B

070645 93
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

135682 ZE 1: operation telescoping end of stroke switch 2 shut-down defective B

135683 ZE 1: operation telescoping end of stroke switch 3 shut-down defective B

135684 ZE 1: operation telescoping shut-down both limit switches "transp. setting N" defect./missing B

135689 ZE 1: operation telescoping Shut-down hoist limit switch 4 faulty B

135690 ZE 1: operation telescoping cylinder bolting is neither unpinned nor in a pivot section B

135691 ZE 1: operation telescoping telescope OUT/IN shut-down, cylinder is not pinned B

135706 ZE 1: operation luffing upper angle limit OGW shut-down B 1


operational shut down
luff main boom down until radius is within load chart again - shut-down can be shunted (danger)

135707 ZE 1: operation luffing lower angle limit UGW shut-down B 1


operational shut down
luff main boom up until radius is within load chart again- shut-down can be shunted (danger)

135708 ZE 1: operation luffing luffing up of main boom shut-down working area limitation ABB B 1
operational shut down
luff main boom down until crane is in working area again - shunting through shut-down of working area limitation

135709 ZE 1: operation luffing luffing down of main boom shut-down working area limitation ABB B 1
operational shut down
luff main boom up until crane in working area again - shunting through shut-down of working area limitation

070645 94
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

135710 ZE 1: operation luffing fly jib upper stop shut-down B

135711 ZE 1: operation luffing fly jib upper flap shut-down B

135712 ZE 1: operation luffing shut-down as lower fly jib and NA-boom 3 not positioned B

135713 ZE 1: operation luffing shut-down as flap not positioned and angle threshold exceeded B

135714 ZE 1: operation luffing pressure retaining cylinder RFP N shut-down outside set range B

135715 ZE 1: operation luffing adjustable pulley-N on stop shut-down B

135719 ZE 1: operation luffing no or invalid operation mode shut-down B 1

135720 ZE 1: operation luffing LMB shut-down B 1


operational shut down
eliminate cause of the "LMB Stop" see error report LMB - shut-down can be shunted (danger)

135723 ZE 1: operation luffing transport setting assembly unit-N shut-down B

135730 ZE 1: operation luffing master switch 1 defective/missing B 1


operational shut down
briefly release master switch, or error elimination see corresponding system error

070645 95
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

135739 ZE 1: operation luffing seat contact shut-down B 1


operational shut down
sit down (seat limit switch) or dead man (in master switch) or check LICCON input, sensor lines, sensor

135741 ZE 1: operation luffing Luffing down shut-down, pressure supply auxiliary consumer selected B

135743 ZE 1: operation luffing Shut-down, telescoping selected B

135744 ZE 1: operation luffing Shut-off crane engine not running B

135747 ZE 1: operation luffing Warning luffing up, dropping of load with reduction of reach B

135748 ZE 1: operation luffing Shut-down luffing up, dropping of load with reduction of reach B

135749 ZE 1: operation luffing Shut-down hoist limit switch 4 B 1


operational shut down
luff main boom up until end of stroke switch is no longer activated - shut-down can be shunted(danger)

135750 ZE 1: operation luffing end of stroke switch shut-down 1 B 1


operational shut down
luff main boom up until end of stroke switch is no longer activated - shut-down can be shunted(danger)

135751 ZE 1: operation luffing end of stroke switch shut-down 2 B 1


operational shut down
luff main boom up until end of stroke switch is no longer activated - shut-down can be shunted(danger)

135752 ZE 1: operation luffing end of stroke switch shut-down 3 B 1


operational shut down
luff main boom up until end of stroke switch is no longer activated - shut-down can be shunted(danger)

070645 96
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

135760 ZE 1: operation luffing Shut-down limit switch main boom steep B

135770 ZE 1: operation luffing shut-down both limit switches "flap in position" defect./missing B

135772 ZE 1: operation luffing shut-down both angle sensors "fly jib" defective/missing B

135773 ZE 1: operation luffing shut-down both limit switches "lower fly jib" defective/missing B

135774 ZE 1: operation luffing shut-down both limit switches "upper fly jib flap" defect./missing B

135775 ZE 1: operation luffing shut-down both limit switches "upper fly jib stop"defect./missing B

135776 ZE 1: operation luffing shut-down limit switch adjustable pulley-N defective/missing B

135781 ZE 1: operation luffing end of stroke switch 1 shut-down defective B

135782 ZE 1: operation luffing end of stroke switch 2 shut-down defective B

135783 ZE 1: operation luffing end of stroke switch 3 shut-down defective B

070645 97
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

135784 ZE 1: operation luffing shut-down both limit switches "transp. setting N" defect./missing B

135789 ZE 1: operation luffing Shut-down hoist limit switch 4 faulty B

136006 ZE 1: operation additional equipment Shut off Luffing up fixed jib upper limit angle OGW B 1
operational shut down
luff main boom down until radius is within load chart again - shut-down can be shunted (danger)

136007 ZE 1: operation additional equipment Shut off Luffing down fixed jib lower limit angle UGW B 1
operational shut down
luff main boom up until radius is within load chart again- shut-down can be shunted (danger)

136008 ZE 1: operation additional equipment Shut off Luffing up fixed jib working range limitation ABB B 1
operational shut down
luff main boom down until crane is in working area again - shunting through shut-down of working area limitation

136009 ZE 1: operation additional equipment Shut off Luffing down fixed jib working range limitation ABB B 1
operational shut down
luff main boom up until crane in working area again - shunting through shut-down of working area limitation

136019 ZE 1: operation additional equipment no or invalid operation mode shut-down B 1

136020 ZE 1: operation additional equipment LMB shut-down B 1


operational shut down
eliminate cause of the "LMB Stop" see error report LMB - shut-down can be shunted (danger)

136030 ZE 1: operation additional equipment master switch 1 defective/missing B 1


operational shut down
briefly release master switch, or error elimination see corresponding system error

136039 ZE 1: operation additional equipment seat contact shut-down B 1


operational shut down
sit down (seat limit switch) or dead man (in master switch) or check LICCON input, sensor lines, sensor

070645 98
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

136041 ZE 1: operation additional equipment Emerg. op. crane control switched on Caution shut-down ineffective B

136044 ZE 1: operation additional equipment Shut-off crane engine not running B

136047 ZE 1: operation additional equipment Warning luffing up, dropping of load with reduction of reach B

136048 ZE 1: operation additional equipment Shut-down luffing up, dropping of load with reduction of reach B

136049 ZE 1: operation additional equipment Shut off Luffing down fixed jib hoist limit switch 4 B 1
operational shut down
luff main boom up until end of stroke switch is no longer activated - shut-down can be shunted(danger)

136050 ZE 1: operation additional equipment Shut off Luffing down fixed jib hoist limit switch 1 B 1
operational shut down
luff main boom up until end of stroke switch is no longer activated - shut-down can be shunted(danger)

136051 ZE 1: operation additional equipment Shut off Luffing down fixed jib hoist limit switch 2 B 1
operational shut down
luff main boom up until end of stroke switch is no longer activated - shut-down can be shunted(danger)

136052 ZE 1: operation additional equipment Shut off Luffing down fixed jib hoist limit switch 3 B 1
operational shut down
luff main boom up until end of stroke switch is no longer activated - shut-down can be shunted(danger)

136081 ZE 1: operation additional equipment Shut off Luff down fixed jib hoist limit switch 1 erroneous/missing B

136082 ZE 1: operation additional equipment Shut off Luff down fixed jib hoist limit switch 2 erroneous/missing B

070645 99
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

136083 ZE 1: operation additional equipment Shut off Luff down fixed jib hoist limit switch 3 erroneous/missing B

136089 ZE 1: operation additional equipment Shut off Luff down fixed jib hoist limit switch 4 erroneous/missing B

137201 ZE 1: operation instruments armrest right master switch 1X not in neutral when starting B 1
output of error, shut-down through application
release master switch briefly or check LICCON input, gear lines, sensor

137312 ZE 1: operation instruments armrest left master switch 2Y not in neutral when starting B 1
output of error, shut-down through application
release master switch briefly or check LICCON input, gear lines, sensor

139800 ZE 1: operation diagnosis system interruption, master switch defective or incorrectly deflected B 1
Carrying out of test program delayed / interrupted
Note direction of movements, carry out test program again

139801 ZE 1: operation diagnosis system interruption, master switch defective/missing B 1


Carrying out of test program delayed / interrupted
Check master switch, carry out test program again

139802 ZE 1: operation diagnosis system interruption, incorrect or no operation mode B 1


Carrying out of test program delayed / interrupted
Set correct operation type, if necessary dismantle accessory, carry out test program again

139814 ZE 1: operation diagnosis system Alignment aid not correctly shut down B 1
Invalid operation condition, no proper crane operation possible
Apply F key, end active test program

139820 ZE 1: operation diagnosis system interruption, boom angle beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Extend to correct luffing position, carry out test program again

139821 ZE 1: operation diagnosis system interruption, tele length beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Extend to correct telescopic boom length length, carry out test program again

070645 100
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

139822 ZE 1: operation diagnosis system interruption, hook load beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Note max. hook load, carry out test program again

139823 ZE 1: operation diagnosis system interruption, incorrect reeving B 1


Carrying out of test program delayed / interrupted
Note lowest amount of reevings, carry out test program again

139824 ZE 1: operation diagnosis system interruption, end of stroke switch activated/defective/missing B 1


Carrying out of test program delayed / interrupted
Check hoist limit switch, carry out test program again

161001 E/A-Modul 1: system error OS-C167 initialising error processor-register erroneous E 2


error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

161002 E/A-Modul 1: system error OS-C167 initialising error test total in EPROM/FLASH erroneous E 2
error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

161006 E/A-Modul 1: system error OS-C167 initialising error RAM erroneous E 2


error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

161013 E/A-Modul 1: system error OS-C167 test total in EPROM/FLASH erroneous E 2


error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

161016 E/A-Modul 1: system error OS-C167 system-, driver-watchdog expired E 2


error indication on display
note error report, ignition ON/OFF, with repeated occurrence --> inform after-sales service

161068 E/A-Modul 1: system error OS-C167 impermissible interrupt E 2


error indication on display
note error report, ignition ON/OFF, with repeated occurrence --> inform after-sales service

161071 E/A-Modul 1: system error OS-C167 Invalid configuration or Firmware E 2


error indication on display
re-load Software from ZE

070645 101
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

161080 E/A-Modul 1: system error OS-C167 fatal internal software error E 2


error indication on display
note error report, ignition ON/OFF, with repeated occurrence --> inform after-sales service

161082 E/A-Modul 1: system error OS-C167 hardware-watchdog erroneous E 2


error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

161088 E/A-Modul 1: system error OS-C167 Configuration does not match software condition E 1
Error output, possible error functions of module
Carry out EAM-download from LICCON

161089 E/A-Modul 1: system error OS-C167 Incorrect version of firmware installed E 1


Error output, possible error functions of module
Replace module, reload firmware

161090 E/A-Modul 1: system error OS-C167 Incorrect hardware version recognised E 1


Error output, possible error functions of module
Replace module

172052 E/A-Modul 1: input/output DEA0 output open, to low load, short circuit to supply voltage X613:17 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

172053 E/A-Modul 1: input/output DEA0 transistor current supply insufficient or missing X613:17 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

172054 E/A-Modul 1: input/output DEA0 short circuit to supply voltage X613:17 E 1


error report on display
check output for short, if necessary replace E/A-Modul

172055 E/A-Modul 1: input/output DEA0 excessive temperature, short circuit to ground or overload X613:17 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

172152 E/A-Modul 1: input/output DEA1 output open, to low load, short circuit to supply voltage X613:15 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

070645 102
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

172153 E/A-Modul 1: input/output DEA1 transistor current supply insufficient or missing X613:15 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

172154 E/A-Modul 1: input/output DEA1 short circuit to supply voltage X613:15 E 1


error report on display
check output for short, if necessary replace E/A-Modul

172155 E/A-Modul 1: input/output DEA1 excessive temperature, short circuit to ground or overload X613:15 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

172252 E/A-Modul 1: input/output DEA2 output open, to low load, short circuit to supply voltage X613:13 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

172253 E/A-Modul 1: input/output DEA2 transistor current supply insufficient or missing X613:13 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

172254 E/A-Modul 1: input/output DEA2 short circuit to supply voltage X613:13 E 1


error report on display
check output for short, if necessary replace E/A-Modul

172255 E/A-Modul 1: input/output DEA2 excessive temperature, short circuit to ground or overload X613:13 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

172352 E/A-Modul 1: input/output DEA3 output open, to low load, short circuit to supply voltage X613:11 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

172353 E/A-Modul 1: input/output DEA3 transistor current supply insufficient or missing X613:11 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

172354 E/A-Modul 1: input/output DEA3 short circuit to supply voltage X613:11 E 1


error report on display
check output for short, if necessary replace E/A-Modul

070645 103
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

172355 E/A-Modul 1: input/output DEA3 excessive temperature, short circuit to ground or overload X613:11 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

172452 E/A-Modul 1: input/output DEA4 output open, to low load, short circuit to supply voltage X613:9 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

172453 E/A-Modul 1: input/output DEA4 transistor current supply insufficient or missing X613:9 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

172454 E/A-Modul 1: input/output DEA4 short circuit to supply voltage X613:9 E 1


error report on display
check output for short, if necessary replace E/A-Modul

172455 E/A-Modul 1: input/output DEA4 excessive temperature, short circuit to ground or overload X613:9 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

172552 E/A-Modul 1: input/output DEA5 output open, to low load, short circuit to supply voltage X613:7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

172553 E/A-Modul 1: input/output DEA5 transistor current supply insufficient or missing X613:7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

172554 E/A-Modul 1: input/output DEA5 short circuit to supply voltage X613:7 E 1


error report on display
check output for short, if necessary replace E/A-Modul

172555 E/A-Modul 1: input/output DEA5 excessive temperature, short circuit to ground or overload X613:7 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

172652 E/A-Modul 1: input/output DEA6 output open, to low load, short circuit to supply voltage X613:5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

070645 104
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

172653 E/A-Modul 1: input/output DEA6 transistor current supply insufficient or missing X613:5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

172654 E/A-Modul 1: input/output DEA6 short circuit to supply voltage X613:5 E 1


error report on display
check output for short, if necessary replace E/A-Modul

172655 E/A-Modul 1: input/output DEA6 excessive temperature, short circuit to ground or overload X613:5 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

172752 E/A-Modul 1: input/output DEA7 output open, to low load, short circuit to supply voltage X613:3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

172753 E/A-Modul 1: input/output DEA7 transistor current supply insufficient or missing X613:3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

172754 E/A-Modul 1: input/output DEA7 short circuit to supply voltage X613:3 E 1


error report on display
check output for short, if necessary replace E/A-Modul

172755 E/A-Modul 1: input/output DEA7 excessive temperature, short circuit to ground or overload X613:3 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

173481 E/A-Modul 1: voltage input E4 short circuit to supply voltage, open line X612:9 E 1
symbol for brake pressure 1 is flashing on the display unit
check input signal on the E/A-Modul or sensor

173581 E/A-Modul 1: voltage input E5 short circuit to supply voltage, open line X612:7 E 1
symbol for brake pressure 2 is flashing on the display unit
check input signal on the E/A-Modul or sensor

173782 E/A-Modul 1: voltage input E7 short circuit to ground, open line, constant current 10 mA incorrect X612:3 E 1
no reaction
check input signal on the E/A-Modul or sensor

070645 105
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

173783 E/A-Modul 1: voltage input E7 short circuit to supply voltage, open line, lack of voltage X612:3 E 1
no reaction
check input signal on the E/A-Modul or sensor

179052 E/A-Modul 1: output A0 output open, to low load, short circuit to supply voltage X613:18 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

179053 E/A-Modul 1: output A0 transistor current supply insufficient or missing X613:18 E 1


error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

179054 E/A-Modul 1: output A0 short circuit to supply voltage X613:18 E 1


error report on display
check output for short, if necessary replace E/A-Modul

179055 E/A-Modul 1: output A0 excessive temperature, short circuit to ground or overload X613:18 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

179152 E/A-Modul 1: output A1 output open, to low load, short circuit to supply voltage X613:16 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

179153 E/A-Modul 1: output A1 transistor current supply insufficient or missing X613:16 E 1


error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

179154 E/A-Modul 1: output A1 short circuit to supply voltage X613:16 E 1


error report on display
check output for short, if necessary replace E/A-Modul

179155 E/A-Modul 1: output A1 excessive temperature, short circuit to ground or overload X613:16 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

179250 E/A-Modul 1: bridge output A2 short circuit to ground, junction not supplied X613:14 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul

070645 106
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

179251 E/A-Modul 1: bridge output A2 short circuit to supply voltage, excessive temperature X613:14 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul

179252 E/A-Modul 1: bridge output A2 output open, to low load, short circuit to supply voltage X613:14 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

179253 E/A-Modul 1: bridge output A2 transistor current supply insufficient or missing X613:14 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

179254 E/A-Modul 1: bridge output A2 short circuit to supply voltage X613:14 E 1


error report on display
check output for short, if necessary replace E/A-Modul

179255 E/A-Modul 1: bridge output A2 excessive temperature, short circuit to ground or overload X613:14 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

179350 E/A-Modul 1: bridge output A3 short circuit to ground, junction not supplied X613:12 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul

179351 E/A-Modul 1: bridge output A3 short circuit to supply voltage, excessive temperature X613:12 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul

179352 E/A-Modul 1: bridge output A3 output open, to low load, short circuit to supply voltage X613:12 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

179353 E/A-Modul 1: bridge output A3 transistor current supply insufficient or missing X613:12 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

179354 E/A-Modul 1: bridge output A3 short circuit to supply voltage X613:12 E 1


error report on display
check output for short, if necessary replace E/A-Modul

070645 107
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

179355 E/A-Modul 1: bridge output A3 excessive temperature, short circuit to ground or overload X613:12 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

183401 E/A-Modul 1: SPI-control unit Faulty data transfer E/A-module<>unit (time exceeded) X614:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul

183402 E/A-Modul 1: SPI-control unit Serious system error to SPI-connection (interface) X614:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul

183403 E/A-Modul 1: SPI-control unit break in line or short circuit to supply voltage X614:1/2/3/5/6/ E 1
error indication on display 7/8
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary

183404 E/A-Modul 1: SPI-control unit break in line or short circuit to ground X614:1/2/3/5/6/ E 1
error indication on display 7/8
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary

183406 E/A-Modul 1: SPI-control unit Data transfer faulty (faulty check byte) X614:1/2/3/5/6/ E 1
error indication on display 7/8
suppress EMV- interference

183407 E/A-Modul 1: SPI-control unit Unit faulty/missing, incorrect unit inserted (ID) X614:1/2/3/5/6/ E 1
error indication on display 7/8
check periphery and replace if necessary, check Software version, check EMV- interference

183408 E/A-Modul 1: SPI-control unit Data transfer faulty (incorrect number of data bytes received) X614:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul

183900 E/A-Modul 1: Control operating unit (SPI) Faulty initialisation data connection E/A-module<>unit X614:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul

183902 E/A-Modul 1: Control operating unit (SPI) Serious system error to SPI-connection (interface) X614:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul

070645 108
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

183905 E/A-Modul 1: Control operating unit (SPI) Initialisation error, resetting inputs/outputs faulty X614:1/2/3/5/6/ E 1
error indication on display 7/8
check wiring, check periphery and replace if necessary, check E/A-Modul and replace if necessary

183907 E/A-Modul 1: Control operating unit (SPI) Unit faulty/missing, incorrect unit inserted (ID) X614:1/2/3/5/6/ E 1
error indication on display 7/8
connect functional periphery unit, system then eliminates error independently

183908 E/A-Modul 1: Control operating unit (SPI) Data transfer faulty (incorrect number of data bytes received) X614:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul

184104 E/A-Modul 1: LSB-B participant address 1 level exceeded X613:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

184105 E/A-Modul 1: LSB-B participant address 1 below minimum level X613:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

184118 E/A-Modul 1: LSB-B participant address 1 excess temperature X613:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

184150 E/A-Modul 1: LSB-B participant address 1 reports an incorrect sensor type X613:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

184151 E/A-Modul 1: LSB-B participant address 1 was not configured for the block transfer X613:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

184153 E/A-Modul 1: LSB-B participant address 1 no longer reports or withdrawn during running period X613:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

184154 E/A-Modul 1: LSB-B participant address 1 Features other settings (parameters) as pre-entered set values X613:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

070645 109
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

184164 E/A-Modul 1: LSB-B participant address 1 reports tolerable error in self-test X613:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

184165 E/A-Modul 1: LSB-B participant address 1 reports intolerable error in self-test X613:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

184166 E/A-Modul 1: LSB-B participant address 1 with software version, that is no longer compatible X613:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

184167 E/A-Modul 1: LSB-B participant address 1 supports no download function X613:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

184204 E/A-Modul 1: LSB-B participant address 2 level exceeded X613:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

184205 E/A-Modul 1: LSB-B participant address 2 below minimum level X613:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

184218 E/A-Modul 1: LSB-B participant address 2 excess temperature X613:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

184250 E/A-Modul 1: LSB-B participant address 2 reports an incorrect sensor type X613:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

184251 E/A-Modul 1: LSB-B participant address 2 was not configured for the block transfer X613:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

184253 E/A-Modul 1: LSB-B participant address 2 no longer reports or withdrawn during running period X613:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

070645 110
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

184254 E/A-Modul 1: LSB-B participant address 2 Features other settings (parameters) as pre-entered set values X613:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

184264 E/A-Modul 1: LSB-B participant address 2 reports tolerable error in self-test X613:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

184265 E/A-Modul 1: LSB-B participant address 2 reports intolerable error in self-test X613:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

184266 E/A-Modul 1: LSB-B participant address 2 with software version, that is no longer compatible X613:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

184267 E/A-Modul 1: LSB-B participant address 2 supports no download function X613:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

184304 E/A-Modul 1: LSB-B participant address 3 level exceeded X613:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

184305 E/A-Modul 1: LSB-B participant address 3 below minimum level X613:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

184318 E/A-Modul 1: LSB-B participant address 3 excess temperature X613:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

184350 E/A-Modul 1: LSB-B participant address 3 reports an incorrect sensor type X613:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

184351 E/A-Modul 1: LSB-B participant address 3 was not configured for the block transfer X613:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

070645 111
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

184353 E/A-Modul 1: LSB-B participant address 3 no longer reports or withdrawn during running period X613:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

184354 E/A-Modul 1: LSB-B participant address 3 Features other settings (parameters) as pre-entered set values X613:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

184364 E/A-Modul 1: LSB-B participant address 3 reports tolerable error in self-test X613:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

184365 E/A-Modul 1: LSB-B participant address 3 reports intolerable error in self-test X613:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

184366 E/A-Modul 1: LSB-B participant address 3 with software version, that is no longer compatible X613:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

184367 E/A-Modul 1: LSB-B participant address 3 supports no download function X613:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

184404 E/A-Modul 1: LSB-B participant address 4 level exceeded X613:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

184405 E/A-Modul 1: LSB-B participant address 4 below minimum level X613:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

184418 E/A-Modul 1: LSB-B participant address 4 excess temperature X613:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

184450 E/A-Modul 1: LSB-B participant address 4 reports an incorrect sensor type X613:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

070645 112
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

184451 E/A-Modul 1: LSB-B participant address 4 was not configured for the block transfer X613:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

184453 E/A-Modul 1: LSB-B participant address 4 no longer reports or withdrawn during running period X613:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

184454 E/A-Modul 1: LSB-B participant address 4 Features other settings (parameters) as pre-entered set values X613:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

184464 E/A-Modul 1: LSB-B participant address 4 reports tolerable error in self-test X613:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

184465 E/A-Modul 1: LSB-B participant address 4 reports intolerable error in self-test X613:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

184466 E/A-Modul 1: LSB-B participant address 4 with software version, that is no longer compatible X613:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

184467 E/A-Modul 1: LSB-B participant address 4 supports no download function X613:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

184504 E/A-Modul 1: LSB-B participant address 5 level exceeded X613:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

184505 E/A-Modul 1: LSB-B participant address 5 below minimum level X613:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

184518 E/A-Modul 1: LSB-B participant address 5 excess temperature X613:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

070645 113
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

184550 E/A-Modul 1: LSB-B participant address 5 reports an incorrect sensor type X613:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

184551 E/A-Modul 1: LSB-B participant address 5 was not configured for the block transfer X613:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

184553 E/A-Modul 1: LSB-B participant address 5 no longer reports or withdrawn during running period X613:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

184554 E/A-Modul 1: LSB-B participant address 5 Features other settings (parameters) as pre-entered set values X613:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

184564 E/A-Modul 1: LSB-B participant address 5 reports tolerable error in self-test X613:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

184565 E/A-Modul 1: LSB-B participant address 5 reports intolerable error in self-test X613:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

184566 E/A-Modul 1: LSB-B participant address 5 with software version, that is no longer compatible X613:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

184567 E/A-Modul 1: LSB-B participant address 5 supports no download function X613:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

184604 E/A-Modul 1: LSB-B participant address 6 level exceeded X613:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

184605 E/A-Modul 1: LSB-B participant address 6 below minimum level X613:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

070645 114
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

184618 E/A-Modul 1: LSB-B participant address 6 excess temperature X613:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

184650 E/A-Modul 1: LSB-B participant address 6 reports an incorrect sensor type X613:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

184651 E/A-Modul 1: LSB-B participant address 6 was not configured for the block transfer X613:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

184653 E/A-Modul 1: LSB-B participant address 6 no longer reports or withdrawn during running period X613:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

184654 E/A-Modul 1: LSB-B participant address 6 Features other settings (parameters) as pre-entered set values X613:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

184664 E/A-Modul 1: LSB-B participant address 6 reports tolerable error in self-test X613:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

184665 E/A-Modul 1: LSB-B participant address 6 reports intolerable error in self-test X613:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

184666 E/A-Modul 1: LSB-B participant address 6 with software version, that is no longer compatible X613:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

184667 E/A-Modul 1: LSB-B participant address 6 supports no download function X613:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

187252 E/A-Modul 1: Control data transfer LSB-B has recognised Bus collisions, communication interrupted X613:4/6 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor

070645 115
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

187255 E/A-Modul 1: Control data transfer LSB-B Bus connection faulty/defect, short circuit to supply voltage X613:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

187256 E/A-Modul 1: Control data transfer LSB-B Bus connection faulty/defect, no supply/short circuit to earth X613:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

187257 E/A-Modul 1: Control data transfer LSB-B has recognised network re-set (data transfer starts again) X613:4/6 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part

187258 E/A-Modul 1: Control data transfer LSB-B recognised participant with incorrect baud rate in bus X613:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors

187259 E/A-Modul 1: Control data transfer LSB-B recognised communication breakdown in bus X613:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network

187260 E/A-Modul 1: Control data transfer LSB-B driver error: no order to carry out X613:4/6 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software

187261 E/A-Modul 1: Control data transfer LSB-B driver error: undefined message appears X613:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination

187262 E/A-Modul 1: Control data transfer LSB-B Driver error: Initialization error X613:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination

187530 E/A-Modul 1: CAN-participant engine Data transfer subscriber transfer cycle exceeded X615:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul

187531 E/A-Modul 1: CAN-participant engine Data transfer faulty/missing, max. cycle time exceeded X615:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

070645 116
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

187630 E/A-Modul 1: CAN-participant gear Data transfer subscriber transfer cycle exceeded X615:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul

187631 E/A-Modul 1: CAN-participant gear Data transfer faulty/missing, max. cycle time exceeded X615:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

187730 E/A-Modul 1: CAN-participant ABV (ABS/ASR) Data transfer subscriber transfer cycle exceeded X615:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul

187731 E/A-Modul 1: CAN-participant ABV (ABS/ASR) Data transfer faulty/missing, max. cycle time exceeded X615:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

187930 E/A-Modul 1: CAN-participant retarder Data transfer subscriber transfer cycle exceeded X615:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul

187931 E/A-Modul 1: CAN-participant retarder Data transfer faulty/missing, max. cycle time exceeded X615:5/6 E 1
parameterised substitute values for receiver signals will be used
Check CAN network, check faulty Bus user.

188030 E/A-Modul 1: CAN-user converter clutch unit CCU Data transfer subscriber transfer cycle exceeded X615:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul

188031 E/A-Modul 1: CAN-user converter clutch unit CCU Data transfer faulty/missing, max. cycle time exceeded X615:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

188530 E/A-Modul 1: CAN-participant E/A-Modul 1 Data transfer subscriber transfer cycle exceeded X615:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant

188531 E/A-Modul 1: CAN-participant E/A-Modul 1 Data transfer faulty/missing, max. cycle time exceeded X615:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

070645 117
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

188930 E/A-Modul 1: CAN-participant E/A-Modul 5 Data transfer subscriber transfer cycle exceeded X615:5/6 E 1
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant

188931 E/A-Modul 1: CAN-participant E/A-Modul 5 Data transfer faulty/missing, max. cycle time exceeded X615:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

189900 E/A-Modul 1: Control data transfer CAN internal error at Register-check Controller X615:5/6 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul

189901 E/A-Modul 1: Control data transfer CAN internal error at RAM-check Controller X615:5/6 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul

189902 E/A-Modul 1: Control data transfer CAN Configuration error Software X615:5/6 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul, check Software (test system ZE)

189903 E/A-Modul 1: Control data transfer CAN Transfer interrupted after continuous error X615:5/6 E 1
CAN-Transmission will be aborted
check bus lines/neutral point, replace neutral point or E/A-Modul

189910 E/A-Modul 1: Control data transfer CAN short-term error in bus connection X615:5/6 E 0
re-attachment of Modul to bus transmission
check bus lines/neutral point, unplug individual bus participant and check if error has been eliminated

189911 E/A-Modul 1: Control data transfer CAN permanent error bus connection X615:5/6 E 1
cyclic re-attachment of Modul to bus transmission
check bus lines/neutral point, unplug individual bus participant and check if error has been eliminated

189920 E/A-Modul 1: Control data transfer CAN active participant not responding X615:5/6 E 0
parameterised substitute values for receiver signals will be used
check error report for missing participant(s), test system ZE

189921 E/A-Modul 1: Control data transfer CAN No active subscriber responding X615:5/6 E 1
parameterised substitute values for receiver signals will be used
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul

070645 118
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

189950 E/A-Modul 1: Control data transfer CAN erroneous command test system X615:5/6 E 1
no reaction to unknown test system control command in CAN-System Software
check Software (test system)

192001 E/A-Modul 1: control engine long-term disruption E/A-Modul <-> engine control E 1
engine control and E/A-Modul at emergency speed
engine control and E/A-Modul, check CAN-bus-connections

192110 E/A-Modul 1: control transmission long-term disruption shift selector operation unit <-> gears E 1
transmission control and E/A-Modul (operation unit) in emergency drive program
check transmission control and E/A-Modul, CAN-bus-connection

192112 E/A-Modul 1: control transmission long-term disruption connection E/A-Modul <-> operation unit E 1
transmission control and E/A-Modul (operation unit) in emergency drive program
check connection E/A-Modul<>operation unit, power supplies operation unit; replace E/A- Modul or operation unit

192113 E/A-Modul 1: control transmission error in shift selector keys operation unit: key sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit

192114 E/A-Modul 1: control transmission shift selector operation unit: D key sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit

192115 E/A-Modul 1: control transmission shift selector operation unit: N key sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit

192116 E/A-Modul 1: control transmission shift selector operation unit: R key sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit

192117 E/A-Modul 1: control transmission shift selector operation unit: gear+ key sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit

192118 E/A-Modul 1: control transmission shift selector operation unit: gear- key sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit

070645 119
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

192119 E/A-Modul 1: control transmission shift selector operation unit: travel program key 1/2 sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit

192128 E/A-Modul 1: control transmission feedback of off-road gear simultaneously ON and OFF E 1
control system prevents disengagement of the off-road gear ON or OFF, remaining in actual position when ignition ON
check sensor for acknowledgement(s), check line connections to the E/A-Modul, replace E/A-Modul

193455 E/A-Modul 1: control lighting amperage indicator erroneous E


function is not carried out
use original incandescent lamps, check indicator system for short to supply voltage

193456 E/A-Modul 1: control lighting vehicle indicator defective E


function is not carried out
check indicator system

194190 E/A-Modul 1: LSB-bus participant ZE missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

194192 E/A-Modul 1: LSB-bus participant E/A-Modul 2 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

194193 E/A-Modul 1: LSB-bus participant E/A-Modul 3 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

194194 E/A-Modul 1: LSB-bus participant E/A-Modul 4 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

194195 E/A-Modul 1: LSB-bus participant E/A-Modul 5 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

194800 E/A-Modul 1: control diagnosis system error in diagnosis requirement CAN-participant engine E 0
ISO-Diagnosis-inquiry will be interrupted and if necessary carried out again
check CAN-network, check CAN-paticipants

070645 120
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

194801 E/A-Modul 1: control diagnosis system error in diagnosis requirement CAN-participant gears E 0
ISO-Diagnosis-inquiry will be interrupted and if necessary carried out again
check CAN-network, check CAN-paticipants

194802 E/A-Modul 1: control diagnosis system error in diagnosis requirement CAN-participant ABS E 0
ISO-Diagnosis-inquiry will be interrupted and if necessary carried out again
check CAN-network, check CAN-paticipants

194810 E/A-Modul 1: control diagnosis system error in test system-diagnosis CAN-participant engine E 0
ISO-Diagnosis-inquiry will be interrupted and if necessary carried out again
check CAN-network, check CAN-paticipants

194811 E/A-Modul 1: control diagnosis system error in test system-diagnosis CAN-participant gears E 0
ISO-Diagnosis-inquiry will be interrupted and if necessary carried out again
check CAN-network, check CAN-paticipants

194812 E/A-Modul 1: control diagnosis system error in test system-diagnosis CAN-participant ABS E 0
ISO-Diagnosis-inquiry will be interrupted and if necessary carried out again
check CAN-network, check CAN-paticipants

195150 E/A-Modul 1: operation transmission gears in emergency shift selector operation B


function is not carried out

195151 E/A-Modul 1: operation transmission CAN-connection shift selector <-> gear electronics malfunctioning B
function is not carried out

195152 E/A-Modul 1: operation transmission connection shift selector <-> keyboard unit malfunctioning B
function is not carried out

195153 E/A-Modul 1: operation transmission pre-selection not neutral/crane op. cab malfunction <-> E/A-Modul B
function is not carried out

195154 E/A-Modul 1: operation transmission shift selector out of order: upper-carriage-operation mode B
function is not carried out

070645 121
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

195161 E/A-Modul 1: operation transmission shift selector out of order: key sticking B
function is not carried out

195172 E/A-Modul 1: operation transmission selection of travel direction prevented, op. type not recognized B
function is not carried out

195173 E/A-Modul 1: operation transmission selection of travel dir. prevented, multi-shift selector keys activ. B
function is not carried out

195174 E/A-Modul 1: operation transmission shift selector out of order when engine OFF B
function is not carried out

195175 E/A-Modul 1: operation transmission selection of travel dir. prevented, pre-selection in neutral only B
function is not carried out

195176 E/A-Modul 1: operation transmission selection of travel direction prevented, operation brake not active B
function is not carried out

195179 E/A-Modul 1: operation transmission pre-selection gear+ prevented, maximum gear attained B
function is not carried out

195180 E/A-Modul 1: operation transmission pre-selection gear+ prevented, rear axle not locked B
function is not carried out

195182 E/A-Modul 1: operation transmission pre-selection gear+/- prevented, gear in neutral B


function is not carried out

195183 E/A-Modul 1: operation transmission pre-selection gear- prevented, minimum gear attained B
function is not carried out

070645 122
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

195190 E/A-Modul 1: operation transmission travel program change-over only possible in neutral B
function is not carried out

195500 E/A-Modul 1: operation axle suspension function simultaneously ON and OFF B


function is not carried out
do not simultaneously activate contrasting function keys

195501 E/A-Modul 1: operation axle suspension operation of 2-hand-function without activation of 2-hand-key B
function is not carried out
activate both keys simultaneously or start test program of keyboard unit

195503 E/A-Modul 1: operation axle suspension operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)

195505 E/A-Modul 1: operation axle suspension operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode

195509 E/A-Modul 1: operation axle suspension unauthorised operation from under-carriage B


function is not carried out
start engine and repeat operation

195570 E/A-Modul 1: operation axle suspension undefined condition: neither blocked nor with suspension B
function is not carried out
check blocked limit switch and buffered limit switch

195571 E/A-Modul 1: operation axle suspension undefined condition: blocked and with suspension B
function is not carried out
check blocked limit switch and buffered limit switch

195572 E/A-Modul 1: operation axle suspension function only possible on condition "axles with suspension" B
function is not carried out
switch axle suspension to suspended and lower axle, then block axles 5+6 and level axle suspension

195573 E/A-Modul 1: operation axle suspension function only possible on condition "axles blocked" B
function is not carried out
switch on axle blocking

070645 123
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

195574 E/A-Modul 1: operation axle suspension unauthorised switch-over in condition "axles with suspension" B
function is not carried out
lift blockage of function

195575 E/A-Modul 1: operation axle suspension unauthorised switch-over in condition "axles blocked" B
function is not carried out
lift blockage of function

195601 E/A-Modul 1: operation level/filling/draining operation of 2-hand-function without activation of 2-hand-key B


function is not carried out
activate both keys simultaneously or start test program of keyboard unit

195603 E/A-Modul 1: operation level/filling/draining operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)

195605 E/A-Modul 1: operation level/filling/draining operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode

195609 E/A-Modul 1: operation level/filling/draining unauthorised operation from under-carriage B


function is not carried out
start engine and repeat operation

195640 E/A-Modul 1: operation level/filling/draining level with blocked axle suspension B


function is not carried out
switch axles to suspended condition

195641 E/A-Modul 1: operation level/filling/draining simultaneous filling and draining selected B


function is not carried out
select either filling or draining

195642 E/A-Modul 1: operation level/filling/draining no individual operation when level function is active B
function is not carried out
only activate level key

195643 E/A-Modul 1: operation level/filling/draining gears not in neutral B


function is not carried out
switch transmission to neutral (N)

070645 124
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

195701 E/A-Modul 1: operation axle compensation operation of 2-hand-function without activation of 2-hand-key B
function is not carried out

195707 E/A-Modul 1: operation axle compensation operation from under-carriage without initialisation B
function is not carried out

195709 E/A-Modul 1: operation axle compensation unauthorised operation from under-carriage B


function is not carried out

195747 E/A-Modul 1: operation axle compensation axle long. compensation switchable only if axle suspens. blocked B
function is not carried out

195901 E/A-Modul 1: operation longitudinal lock operation of 2-hand-function without activation of 2-hand-key B
function is not carried out
activate both keys simultaneously or start test program of keyboard unit

195902 E/A-Modul 1: operation longitudinal lock operation from upper-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)

195903 E/A-Modul 1: operation longitudinal lock operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)

195904 E/A-Modul 1: operation longitudinal lock operation from upper-carriage with under-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to uppercarriage operation mode

195905 E/A-Modul 1: operation longitudinal lock operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode

195906 E/A-Modul 1: operation longitudinal lock operation from upper-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection to E/A-Modul 4

070645 125
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

195907 E/A-Modul 1: operation longitudinal lock operation from under-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection to E/A-Modul 4

195908 E/A-Modul 1: operation longitudinal lock unauthorised operation from upper-carriage B


function is not carried out
start engine and repeat operation

195909 E/A-Modul 1: operation longitudinal lock unauthorised operation from under-carriage B


function is not carried out
start engine and repeat operation

195950 E/A-Modul 1: operation longitudinal lock feedback of off-road gear ON missing B


function is not carried out
check acknowledgement for off-road gear ON

195951 E/A-Modul 1: operation longitudinal lock off-road gear switched off B


function is not carried out
switch on off-road gear

195953 E/A-Modul 1: operation longitudinal lock switch-over prevented as axles are raised B
function is not carried out
switch on off-road gear

196001 E/A-Modul 1: operation transversal lock operation of 2-hand-function without activation of 2-hand-key B
function is not carried out
activate both keys simultaneously or start test program of keyboard unit

196003 E/A-Modul 1: operation transversal lock operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) on E/A-Modul 4, check LSB-connection (see electric circuit diagram)

196005 E/A-Modul 1: operation transversal lock operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode

196007 E/A-Modul 1: operation transversal lock operation from under-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection to E/A-Modul 4

070645 126
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

196009 E/A-Modul 1: operation transversal lock unauthorised operation from under-carriage B


function is not carried out
start engine and repeat operation

196052 E/A-Modul 1: operation transversal lock selection of transversal lock ON with no longitudinal lock selected B
function is not carried out
acivate longitudinal locking

196100 E/A-Modul 1: operation unlocking rear axle function simultaneously ON and OFF B
function is not carried out
do not simultaneously activate contrasting function keys

196101 E/A-Modul 1: operation unlocking rear axle operation of 2-hand-function without activation of 2-hand-key B
function is not carried out
activate both keys simultaneously or start test program of keyboard unit

196102 E/A-Modul 1: operation unlocking rear axle operation from upper-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)

196103 E/A-Modul 1: operation unlocking rear axle operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)

196104 E/A-Modul 1: operation unlocking rear axle operation from upper-carriage with under-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to uppercarriage operation mode

196105 E/A-Modul 1: operation unlocking rear axle operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode

196106 E/A-Modul 1: operation unlocking rear axle operation from upper-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection to E/A-Modul 4

196107 E/A-Modul 1: operation unlocking rear axle operation from under-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection to E/A-Modul 4

070645 127
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

196108 E/A-Modul 1: operation unlocking rear axle unauthorised operation from upper-carriage B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

196109 E/A-Modul 1: operation unlocking rear axle unauthorised operation from under-carriage B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

196111 E/A-Modul 1: operation unlocking rear axle unauthorised switching on of function B


function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

196112 E/A-Modul 1: operation unlocking rear axle unauthorised switching off of function B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

196113 E/A-Modul 1: operation unlocking rear axle unauthorised function activation B


function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

196114 E/A-Modul 1: operation unlocking rear axle activation of function without operation mode B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

196115 E/A-Modul 1: operation unlocking rear axle gear limit forwards exceeded with under-carriage operation mode B
function is not carried out
engage lower gear

196116 E/A-Modul 1: operation unlocking rear axle gear limit backwards exceeded with under-carriage operation mode B
function is not carried out
engage lower gear

196117 E/A-Modul 1: operation unlocking rear axle gear limit forwards exceeded with upper-carriage operation mode B
function is not carried out
engage lower gear

196118 E/A-Modul 1: operation unlocking rear axle gear limit backwards exceeded with upper-carriage operation mode B
function is not carried out
engage lower gear

070645 128
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

196119 E/A-Modul 1: operation unlocking rear axle no direction with under-carriage operation mode B
function is not carried out
check CAN-connection and LSB-connection

196120 E/A-Modul 1: operation unlocking rear axle no direction with upper-carriage operation mode B
function is not carried out
check CAN-connection and LSB-connection

196160 E/A-Modul 1: operation unlocking rear axle undefined condition: simultaneously locked and unlocked B
function is not carried out
check unlocking condition, Check locking limit switch and unlocking limit switch

196200 E/A-Modul 1: operation steering rear axle function simultaneously ON and OFF B
function is not carried out
do not simultaneously activate contrasting function keys

196202 E/A-Modul 1: operation steering rear axle operation from upper-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)

196203 E/A-Modul 1: operation steering rear axle operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)

196204 E/A-Modul 1: operation steering rear axle operation from upper-carriage with under-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to uppercarriage operation mode

196205 E/A-Modul 1: operation steering rear axle operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode

196208 E/A-Modul 1: operation steering rear axle unauthorised operation from upper-carriage B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

196209 E/A-Modul 1: operation steering rear axle unauthorised operation from under-carriage B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

070645 129
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

196263 E/A-Modul 1: operation steering rear axle no valid lock condition in upper-carriage operation mode B
function is not carried out
check unlocking condition, Check locking limit switch and unlocking limit switch

196264 E/A-Modul 1: operation steering rear axle no valid lock condition in under-carriage operation mode B
function is not carried out
check unlocking condition, Check locking limit switch and unlocking limit switch

196265 E/A-Modul 1: operation steering rear axle unauthorised steering selection in upper-carriage B
function is not carried out
steering only with rear axle unlocked, check LSB-connection

196266 E/A-Modul 1: operation steering rear axle unauthorised steering selection in under-carriage B
function is not carried out
steering only with rear axle unlocked, check LSB-connection

196570 E/A-Modul 1: operation brakes/pneumatics system upper-carriage parking brake only opened after signal CLOSE B
function is not carried out

196661 E/A-Modul 1: operation hydraulics/second. power outputs secondary output pump not engaged as engine ON B
function is not carried out

196662 E/A-Modul 1: operation hydraulics/second. power outputs secondary output pump not disengaged as engine ON B
function is not carried out

196663 E/A-Modul 1: operation hydraulics/second. power outputs secondary output pump not switchable as engine ON B
function is not carried out

196700 E/A-Modul 1: operation off-road gear function simultaneously ON and OFF B


function is not carried out
do not simultaneously activate contrasting function keys

196703 E/A-Modul 1: operation off-road gear operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)

070645 130
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

196704 E/A-Modul 1: operation off-road gear operation from upper-carriage with under-carriage operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)

196705 E/A-Modul 1: operation off-road gear operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to uppercarriage operation mode

196706 E/A-Modul 1: operation off-road gear operation from upper-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection to E/A-Modul 2

196707 E/A-Modul 1: operation off-road gear operation from under-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection to E/A-Modul 2

196775 E/A-Modul 1: operation off-road gear off-road gear and transfer box free in upper-carriage operation mode B
function is not carried out
do not disconnect transfer case in off-road gear ON or off-road gear not ON with disconnection of transfer gear

196776 E/A-Modul 1: operation off-road gear off-road gear and transfer box free in under-carriage operation mode B
function is not carried out
do not disconnect transfer case in off-road gear ON or off-road gear not ON with disconnection of transfer gear

196778 E/A-Modul 1: operation off-road gear speed too high for off-road gear B
function is not carried out
reduce speed

196779 E/A-Modul 1: operation off-road gear off-road gear ON and gears not neutral B
function is not carried out
switch transmission to neutral (N)

197030 E/A-Modul 1: operation heating/air.conditioning switching on air-conditioning only possible with engine running B
function is not carried out
start engine and repeat operation

197182 E/A-Modul 1: operation lighting indicator from upper-carriage in under-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to uppercarriage operation mode

070645 131
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

197183 E/A-Modul 1: operation lighting indicator from under-carriage in upper-carriage operation mode B
function is not carried out
switch off undercarriage indicator

197184 E/A-Modul 1: operation lighting simultaneous left and right indicator B


function is not carried out
check steering column switch or wiring

197185 E/A-Modul 1: operation lighting hazard lights from upper-carriage and under-carriage B
function is not carried out
switch off warning light

197186 E/A-Modul 1: operation lighting rear fog lamp only with light B
function is not carried out
switch on full beam, dipped light or fog light

199890 E/A-Modul 1: operation diagnosis system test program not executable as engine is not OFF B
function is not carried out

199892 E/A-Modul 1: operation diagnosis system test program not executable as not in under-carriage op. mode B
function is not carried out

199895 E/A-Modul 1: operation diagnosis system start not possible as gears not in neutral B
function is not carried out

199909 E/A-Modul 1: operation optional device unauthorised operation from under-carriage B


function is not carried out
start engine and repeat operation

199922 E/A-Modul 1: operation optional device function not available in under-carriage operation mode B
function is not carried out
on customers request

199924 E/A-Modul 1: operation optional device no customized function in under-carriage operation mode B
function is not carried out
on customers request

070645 132
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

200001 ZE 2: system error OS-HC11 (observe parameters) initialising error processor-register erroneous E 2
no crane operation possible
if error re-occurs, then ZE should be replaced

200002 ZE 2: system error OS-HC11 (observe parameters) initialising error test total in EPROM/FLASH erroneous E 2
no crane operation possible
check program memory card or ZE

200006 ZE 2: system error OS-HC11 (observe parameters) initialising error RAM erroneous E 2
no crane operation possible
if error re-occurs, then ZE should be replaced

200007 ZE 2: system error OS-HC11 (observe parameters) UART erroneous E 2


no crane operation possible
if error re-occurs, then ZE should be replaced

200010 ZE 2: system error OS-HC11 (observe parameters) system routine inaccessible E 2


entry in error memory, all crane movements will be stopped

200011 ZE 2: system error OS-HC11 (observe parameters) ZE-watchdog expired E 2


entry in error memory, all crane movements will be stopped
check ZE

200012 ZE 2: system error OS-HC11 (observe parameters) type-identification in EPROM erroneous E 2


entry in error memory, no crane operation possible
check program memory card

200013 ZE 2: system error OS-HC11 (observe parameters) Test sum in FLASH erroneous E 2
entry in error memory, all crane movements will be stopped
check program memory card

200014 ZE 2: system error OS-HC11 (observe parameters) program already running E 2


entry in error memory, all crane movements will be stopped

200015 ZE 2: system error OS-HC11 (observe parameters) program not available E 2


entry in error memory, all crane movements will be stopped

070645 133
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

200016 ZE 2: system error OS-HC11 (observe parameters) system-, driver-watchdog expired E 2


entry in error memory, all crane movements will be stopped

200017 ZE 2: system error OS-HC11 (observe parameters) total of CPU-time distribution too great E 2
entry in error memory, all crane movements will be stopped

200018 ZE 2: system error OS-HC11 (observe parameters) arithmetic overflow (16 Bit) E 2
entry in error memory, all crane movements will be stopped

200019 ZE 2: system error OS-HC11 (observe parameters) division through zero (16 Bit) E 2
entry in error memory, all crane movements will be stopped

200020 ZE 2: system error OS-HC11 (observe parameters) task-watchdog expired E 2


entry in error memory, all crane movements will be stopped

200021 ZE 2: system error OS-HC11 (observe parameters) illegal opcode trap E 2


entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

200022 ZE 2: system error OS-HC11 (observe parameters) task inactive E 2


entry in error memory, all crane movements will be stopped

200023 ZE 2: system error OS-HC11 (observe parameters) program incapable of running (type identification) E 2
entry in error memory, all crane movements will be stopped

200024 ZE 2: system error OS-HC11 (observe parameters) task already used E 2


entry in error memory, all crane movements will be stopped

200025 ZE 2: system error OS-HC11 (observe parameters) realtime-module already used E 2


entry in error memory, all crane movements will be stopped

070645 134
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

200026 ZE 2: system error OS-HC11 (observe parameters) regulator-module already used E 2


entry in error memory, all crane movements will be stopped

200030 ZE 2: system error OS-HC11 (observe parameters) unacceptable bank address E 2


entry in error memory, all crane movements will be stopped

200041 ZE 2: system error OS-HC11 (observe parameters) arithmetic error E 2


entry in error memory, all crane movements will be stopped

200044 ZE 2: system error OS-HC11 (observe parameters) output parameter without effect, from inactive output E 2
entry in error memory, all crane movements will be stopped

200045 ZE 2: system error OS-HC11 (observe parameters) entry parameter undefined, from inactive input E 2
entry in error memory, all crane movements will be stopped

200046 ZE 2: system error OS-HC11 (observe parameters) impermissible regulator parameter E 2


entry in error memory, all crane movements will be stopped

200047 ZE 2: system error OS-HC11 (observe parameters) realtime-control block not available E 2
entry in error memory, all crane movements will be stopped

200048 ZE 2: system error OS-HC11 (observe parameters) realtime-control block inactive E 2


entry in error memory, all crane movements will be stopped

200049 ZE 2: system error OS-HC11 (observe parameters) urgent modul, ZE not available E 2
entry in error memory, no crane operation possible
check ZE

200050 ZE 2: system error OS-HC11 (observe parameters) file not available E 2


entry in error memory, all crane movements will be stopped

070645 135
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

200051 ZE 2: system error OS-HC11 (observe parameters) file already opened E 2


entry in error memory, all crane movements will be stopped

200052 ZE 2: system error OS-HC11 (observe parameters) file not open on close E 2
entry in error memory, all crane movements will be stopped

200053 ZE 2: system error OS-HC11 (observe parameters) system mask not available E 2
entry in error memory, all crane movements will be stopped

200054 ZE 2: system error OS-HC11 (observe parameters) system text not available E 2
entry in error memory, all crane movements will be stopped

200055 ZE 2: system error OS-HC11 (observe parameters) symbol not available E 2


entry in error memory, all crane movements will be stopped

200056 ZE 2: system error OS-HC11 (observe parameters) invalid mark in symbol E 2


entry in error memory, all crane movements will be stopped

200057 ZE 2: system error OS-HC11 (observe parameters) default load chart missing E 2
entry in error memory, all crane movements will be stopped

200058 ZE 2: system error OS-HC11 (observe parameters) amplifier erroneous or return power feed E 2
entry in error memory, all crane movements will be stopped
check wiring

200059 ZE 2: system error OS-HC11 (observe parameters) subroutine not reenterant E 2


entry in error memory, all crane movements will be stopped

200060 ZE 2: system error OS-HC11 (observe parameters) transmission error SCI E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

070645 136
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

200061 ZE 2: system error OS-HC11 (observe parameters) SCI-BREAK E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

200062 ZE 2: system error OS-HC11 (observe parameters) SCI not connected E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

200063 ZE 2: system error OS-HC11 (observe parameters) monitor error in operation E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

200065 ZE 2: system error OS-HC11 (observe parameters) impermissible bus address E 2


entry in error memory, all crane movements will be stopped

200066 ZE 2: system error OS-HC11 (observe parameters) ADC working outside the permissible tolerance E 2
entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

200067 ZE 2: system error OS-HC11 (observe parameters) arithmetic processor not available E 2
entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

200068 ZE 2: system error OS-HC11 (observe parameters) impermissible interrupt E 2


entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

200070 ZE 2: system error OS-HC11 (observe parameters) various structure versions E 2


entry in error memory, no crane operation possible

200071 ZE 2: system error OS-HC11 (observe parameters) Structure file missing or faulty E 2
entry in error memory, no crane operation possible

200072 ZE 2: system error OS-HC11 (observe parameters) structure entry senseless E 2


entry in error memory, no crane operation possible

070645 137
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

200073 ZE 2: system error OS-HC11 (observe parameters) interpreter error E 2


entry in error memory, all crane movements will be stopped

200074 ZE 2: system error OS-HC11 (observe parameters) transformation ASCII to BIN erroneous E 2
entry in error memory, all crane movements will be stopped

200075 ZE 2: system error OS-HC11 (observe parameters) SPI-error E 2


entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

200076 ZE 2: system error OS-HC11 (observe parameters) incorrectly inserted power unit E 2
entry in error memory, all crane movements will be stopped
check memory card in power supply unit

200077 ZE 2: system error OS-HC11 (observe parameters) BAF-call-up erroneous E 2


entry in error memory, all crane movements will be stopped

200078 ZE 2: system error OS-HC11 (observe parameters) impermissible parameter E 2


entry in error memory, all crane movements will be stopped

200079 ZE 2: system error OS-HC11 (observe parameters) no right of access E 2


entry in error memory, all crane movements will be stopped

200080 ZE 2: system error OS-HC11 (observe parameters) Fatal internal error E 2


entry in error memory, all crane movements will be stopped

200081 ZE 2: system error OS-HC11 (observe parameters) stack overflow E 2


entry in error memory, all crane movements will be stopped

200082 ZE 2: system error OS-HC11 (observe parameters) hardware-watchdog erroneous E 2


entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

070645 138
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

200094 ZE 2: system error OS-HC11 (observe parameters) transmission error parallel bus E 2
entry in error memory, all crane movements will be stopped
check ZE, bus circuit board, power supply unit

200095 ZE 2: system error OS-HC11 (observe parameters) DMA-error E 2


entry in error memory, all crane movements will be stopped
check ZE, bus circuit board, power supply unit

200099 ZE 2: system error OS-HC11 (observe parameters) DSP0 erroneous E 2


entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

202001 ZE 2: system error OS-TMS initialising error processor-register erroneous E 2


entry of error in error memory, all crane movements will be stopped
replace ZE

202002 ZE 2: system error OS-TMS initialising error test total in EPROM/FLASH erroneous E 2
entry of error in error memory, all crane movements will be stopped
replace ZE

202006 ZE 2: system error OS-TMS initialising error RAM erroneous E 2


entry of error in error memory, all crane movements will be stopped
replace ZE

202007 ZE 2: system error OS-TMS UART erroneous E 2


entry of error in error memory, all crane movements will be stopped
replace ZE

202020 ZE 2: system error OS-TMS task-watchdog expired E 2


entry of error in error memory, all crane movements will be stopped
elimination only possible through after-sales service

202021 ZE 2: system error OS-TMS illegal opcode trap E 2


entry of error in error memory, all crane movements will be stopped
elimination only possible through after-sales service

202082 ZE 2: system error OS-TMS hardware-watchdog erroneous E 2


entry of error in error memory, all crane movements will be stopped
elimination only possible through after-sales service

070645 139
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

210012 ZE 2: output 0 short circuit to ground X72:16 E 1

210013 ZE 2: output 0 open signal circuits X72:16 E 1

210014 ZE 2: output 0 short circuit to supply voltage X72:16 E 1

210054 ZE 2: output 0 short circuit to supply voltage X72:16 E 1

210058 ZE 2: output 0 positive switching transistor: disruption X72:16 E 1

210060 ZE 2: output 0 safety chain error, diode defect or safety contact sticking X72:16 E 1
report of error, otherwise no reaction
checking of safety contact and diode

210070 ZE 2: output 0 measuring system defect X72:16 E 1


no crane operation possible entry in error list

210071 ZE 2: output 0 short circuit to ground or transistor defect X72:16 E 1

210072 ZE 2: output 0 outside source feeding X72:16 E 1

210073 ZE 2: output 0 open circuit or short circuit to supply voltage/ground X72:16 E 1

070645 140
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

210112 ZE 2: output 1 short circuit to ground X72:17 E 1

210113 ZE 2: output 1 open signal circuits X72:17 E 1

210114 ZE 2: output 1 short circuit to supply voltage X72:17 E 1

210154 ZE 2: output 1 short circuit to supply voltage X72:17 E 1

210158 ZE 2: output 1 positive switching transistor: disruption X72:17 E 1

210160 ZE 2: output 1 safety chain error, diode defect or safety contact sticking X72:17 E 1
report of error, otherwise no reaction
checking of safety contact and diode

210170 ZE 2: output 1 measuring system defect X72:17 E 1


no crane operation possible entry in error list

210171 ZE 2: output 1 short circuit to ground or transistor defect X72:17 E 1

210172 ZE 2: output 1 outside source feeding X72:17 E 1

210173 ZE 2: output 1 open circuit or short circuit to supply voltage/ground X72:17 E 1

070645 141
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

210212 ZE 2: output 2 short circuit to ground X72:18 E 1

210213 ZE 2: output 2 open signal circuits X72:18 E 1

210214 ZE 2: output 2 short circuit to supply voltage X72:18 E 1

210254 ZE 2: output 2 short circuit to supply voltage X72:18 E 1

210258 ZE 2: output 2 positive switching transistor: disruption X72:18 E 1

210270 ZE 2: output 2 measuring system defect X72:18 E 1


no crane operation possible entry in error list

210271 ZE 2: output 2 short circuit to ground or transistor defect X72:18 E 1

210272 ZE 2: output 2 outside source feeding X72:18 E 1

210273 ZE 2: output 2 open circuit or short circuit to supply voltage/ground X72:18 E 1

210312 ZE 2: output 3 short circuit to ground X72:19 E 1

070645 142
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

210313 ZE 2: output 3 open signal circuits X72:19 E 1

210314 ZE 2: output 3 short circuit to supply voltage X72:19 E 1

210354 ZE 2: output 3 short circuit to supply voltage X72:19 E 1

210358 ZE 2: output 3 positive switching transistor: disruption X72:19 E 1

210360 ZE 2: output 3 safety chain error, diode defect or safety contact sticking X72:19 E 1
report of error, otherwise no reaction
checking of safety contact and diode

210370 ZE 2: output 3 measuring system defect X72:19 E 1


no crane operation possible entry in error list

210371 ZE 2: output 3 short circuit to ground or transistor defect X72:19 E 1

210372 ZE 2: output 3 outside source feeding X72:19 E 1

210373 ZE 2: output 3 open circuit or short circuit to supply voltage/ground X72:19 E 1

210412 ZE 2: output 4 short circuit to ground X72:20 E 1

070645 143
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

210413 ZE 2: output 4 open signal circuits X72:20 E 1

210414 ZE 2: output 4 short circuit to supply voltage X72:20 E 1

210454 ZE 2: output 4 short circuit to supply voltage X72:20 E 1

210458 ZE 2: output 4 positive switching transistor: disruption X72:20 E 1

210460 ZE 2: output 4 safety chain error, diode defect or safety contact sticking X72:20 E 1
report of error, otherwise no reaction
checking of safety contact and diode

210470 ZE 2: output 4 measuring system defect X72:20 E 1


no crane operation possible entry in error list

210471 ZE 2: output 4 short circuit to ground or transistor defect X72:20 E 1

210472 ZE 2: output 4 outside source feeding X72:20 E 1

210473 ZE 2: output 4 open circuit or short circuit to supply voltage/ground X72:20 E 1

210512 ZE 2: output 5 short circuit to ground X72:21 E 1

070645 144
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

210513 ZE 2: output 5 open signal circuits X72:21 E 1

210514 ZE 2: output 5 short circuit to supply voltage X72:21 E 1

210554 ZE 2: output 5 short circuit to supply voltage X72:21 E 1

210558 ZE 2: output 5 positive switching transistor: disruption X72:21 E 1

210560 ZE 2: output 5 safety chain error, diode defect or safety contact sticking X72:21 E 1
report of error, otherwise no reaction
checking of safety contact and diode

210570 ZE 2: output 5 measuring system defect X72:21 E 1


no crane operation possible entry in error list

210571 ZE 2: output 5 short circuit to ground or transistor defect X72:21 E 1

210572 ZE 2: output 5 outside source feeding X72:21 E 1

210573 ZE 2: output 5 open circuit or short circuit to supply voltage/ground X72:21 E 1

210612 ZE 2: output 6 short circuit to ground X72:22 E 1

070645 145
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

210613 ZE 2: output 6 open signal circuits X72:22 E 1

210614 ZE 2: output 6 short circuit to supply voltage X72:22 E 1

210654 ZE 2: output 6 short circuit to supply voltage X72:22 E 1

210658 ZE 2: output 6 positive switching transistor: disruption X72:22 E 1

210660 ZE 2: output 6 safety chain error, diode defect or safety contact sticking X72:22 E 1
report of error, otherwise no reaction
checking of safety contact and diode

210670 ZE 2: output 6 measuring system defect X72:22 E 1


no crane operation possible entry in error list

210671 ZE 2: output 6 short circuit to ground or transistor defect X72:22 E 1

210672 ZE 2: output 6 outside source feeding X72:22 E 1

210673 ZE 2: output 6 open circuit or short circuit to supply voltage/ground X72:22 E 1

210712 ZE 2: output 7 short circuit to ground X72:23 E 1

070645 146
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

210713 ZE 2: output 7 open signal circuits X72:23 E 1

210714 ZE 2: output 7 short circuit to supply voltage X72:23 E 1

210754 ZE 2: output 7 short circuit to supply voltage X72:23 E 1

210758 ZE 2: output 7 positive switching transistor: disruption X72:23 E 1

210760 ZE 2: output 7 safety chain error, diode defect or safety contact sticking X72:23 E 1
report of error, otherwise no reaction
checking of safety contact and diode

210770 ZE 2: output 7 measuring system defect X72:23 E 1


no crane operation possible entry in error list

210771 ZE 2: output 7 short circuit to ground or transistor defect X72:23 E 1

210772 ZE 2: output 7 outside source feeding X72:23 E 1

210773 ZE 2: output 7 open circuit or short circuit to supply voltage/ground X72:23 E 1

214959 ZE 2: all output supply voltage missing X72 E 1

070645 147
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

215059 ZE 2: output group 0 supply voltage missing X72:12 E 1

215159 ZE 2: output group 1 supply voltage missing X72:24 E 1

215259 ZE 2: output group 2 supply voltage missing X72:25 E 1

215359 ZE 2: output group 3 supply voltage missing X72:13 E 1

220004 ZE 2: LSB participant address 0 level exceeded X635B:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

220005 ZE 2: LSB participant address 0 below minimum level X635B:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

220018 ZE 2: LSB participant address 0 excess temperature X635B:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

220050 ZE 2: LSB participant address 0 reports an incorrect sensor type X635B:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

220051 ZE 2: LSB participant address 0 was not configured for the block transfer X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

220053 ZE 2: LSB participant address 0 no longer reports or withdrawn during running period X635B:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

070645 148
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

220054 ZE 2: LSB participant address 0 Features other settings (parameters) as pre-entered set values X635B:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

220064 ZE 2: LSB participant address 0 reports tolerable error in self-test X635B:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

220065 ZE 2: LSB participant address 0 reports intolerable error in self-test X635B:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

220066 ZE 2: LSB participant address 0 with software version, that is no longer compatible X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

220067 ZE 2: LSB participant address 0 supports no download function X635B:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

220104 ZE 2: LSB participant address 1 level exceeded X635B:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

220105 ZE 2: LSB participant address 1 below minimum level X635B:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

220118 ZE 2: LSB participant address 1 excess temperature X635B:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

220150 ZE 2: LSB participant address 1 reports an incorrect sensor type X635B:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

220151 ZE 2: LSB participant address 1 was not configured for the block transfer X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

070645 149
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

220153 ZE 2: LSB participant address 1 no longer reports or withdrawn during running period X635B:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

220154 ZE 2: LSB participant address 1 Features other settings (parameters) as pre-entered set values X635B:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

220164 ZE 2: LSB participant address 1 reports tolerable error in self-test X635B:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

220165 ZE 2: LSB participant address 1 reports intolerable error in self-test X635B:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

220166 ZE 2: LSB participant address 1 with software version, that is no longer compatible X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

220167 ZE 2: LSB participant address 1 supports no download function X635B:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

220204 ZE 2: LSB participant address 2 level exceeded X635B:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

220205 ZE 2: LSB participant address 2 below minimum level X635B:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

220218 ZE 2: LSB participant address 2 excess temperature X635B:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

220250 ZE 2: LSB participant address 2 reports an incorrect sensor type X635B:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

070645 150
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

220251 ZE 2: LSB participant address 2 was not configured for the block transfer X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

220253 ZE 2: LSB participant address 2 no longer reports or withdrawn during running period X635B:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

220254 ZE 2: LSB participant address 2 Features other settings (parameters) as pre-entered set values X635B:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

220264 ZE 2: LSB participant address 2 reports tolerable error in self-test X635B:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

220265 ZE 2: LSB participant address 2 reports intolerable error in self-test X635B:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

220266 ZE 2: LSB participant address 2 with software version, that is no longer compatible X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

220267 ZE 2: LSB participant address 2 supports no download function X635B:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

220904 ZE 2: LSB participant address 9 level exceeded X635B:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

220905 ZE 2: LSB participant address 9 below minimum level X635B:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

220918 ZE 2: LSB participant address 9 excess temperature X635B:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

070645 151
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

220950 ZE 2: LSB participant address 9 reports an incorrect sensor type X635B:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

220951 ZE 2: LSB participant address 9 was not configured for the block transfer X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

220953 ZE 2: LSB participant address 9 no longer reports or withdrawn during running period X635B:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

220954 ZE 2: LSB participant address 9 Features other settings (parameters) as pre-entered set values X635B:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

220964 ZE 2: LSB participant address 9 reports tolerable error in self-test X635B:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

220965 ZE 2: LSB participant address 9 reports intolerable error in self-test X635B:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

220966 ZE 2: LSB participant address 9 with software version, that is no longer compatible X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

220967 ZE 2: LSB participant address 9 supports no download function X635B:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

222104 ZE 2: LSB participant address 21 level exceeded X635B:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

222105 ZE 2: LSB participant address 21 below minimum level X635B:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

070645 152
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

222118 ZE 2: LSB participant address 21 excess temperature X635B:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

222150 ZE 2: LSB participant address 21 reports an incorrect sensor type X635B:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

222151 ZE 2: LSB participant address 21 was not configured for the block transfer X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

222153 ZE 2: LSB participant address 21 no longer reports or withdrawn during running period X635B:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

222154 ZE 2: LSB participant address 21 Features other settings (parameters) as pre-entered set values X635B:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

222164 ZE 2: LSB participant address 21 reports tolerable error in self-test X635B:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

222165 ZE 2: LSB participant address 21 reports intolerable error in self-test X635B:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

222166 ZE 2: LSB participant address 21 with software version, that is no longer compatible X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

222167 ZE 2: LSB participant address 21 supports no download function X635B:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

222304 ZE 2: LSB participant address 23 level exceeded X635B:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

070645 153
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

222305 ZE 2: LSB participant address 23 below minimum level X635B:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

222318 ZE 2: LSB participant address 23 excess temperature X635B:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

222350 ZE 2: LSB participant address 23 reports an incorrect sensor type X635B:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

222351 ZE 2: LSB participant address 23 was not configured for the block transfer X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

222353 ZE 2: LSB participant address 23 no longer reports or withdrawn during running period X635B:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

222354 ZE 2: LSB participant address 23 Features other settings (parameters) as pre-entered set values X635B:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

222364 ZE 2: LSB participant address 23 reports tolerable error in self-test X635B:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

222365 ZE 2: LSB participant address 23 reports intolerable error in self-test X635B:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

222366 ZE 2: LSB participant address 23 with software version, that is no longer compatible X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

222367 ZE 2: LSB participant address 23 supports no download function X635B:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

070645 154
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

222404 ZE 2: LSB participant address 24 level exceeded X635B:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

222405 ZE 2: LSB participant address 24 below minimum level X635B:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

222418 ZE 2: LSB participant address 24 excess temperature X635B:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

222450 ZE 2: LSB participant address 24 reports an incorrect sensor type X635B:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

222451 ZE 2: LSB participant address 24 was not configured for the block transfer X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

222453 ZE 2: LSB participant address 24 no longer reports or withdrawn during running period X635B:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

222454 ZE 2: LSB participant address 24 Features other settings (parameters) as pre-entered set values X635B:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

222464 ZE 2: LSB participant address 24 reports tolerable error in self-test X635B:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

222465 ZE 2: LSB participant address 24 reports intolerable error in self-test X635B:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

222466 ZE 2: LSB participant address 24 with software version, that is no longer compatible X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

070645 155
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

222467 ZE 2: LSB participant address 24 supports no download function X635B:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

222604 ZE 2: LSB participant address 26 level exceeded X635B:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

222605 ZE 2: LSB participant address 26 below minimum level X635B:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

222618 ZE 2: LSB participant address 26 excess temperature X635B:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

222650 ZE 2: LSB participant address 26 reports an incorrect sensor type X635B:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

222651 ZE 2: LSB participant address 26 was not configured for the block transfer X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

222653 ZE 2: LSB participant address 26 no longer reports or withdrawn during running period X635B:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

222654 ZE 2: LSB participant address 26 Features other settings (parameters) as pre-entered set values X635B:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

222664 ZE 2: LSB participant address 26 reports tolerable error in self-test X635B:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

222665 ZE 2: LSB participant address 26 reports intolerable error in self-test X635B:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

070645 156
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

222666 ZE 2: LSB participant address 26 with software version, that is no longer compatible X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

222667 ZE 2: LSB participant address 26 supports no download function X635B:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

222704 ZE 2: LSB participant address 27 level exceeded X635B:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

222705 ZE 2: LSB participant address 27 below minimum level X635B:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

222718 ZE 2: LSB participant address 27 excess temperature X635B:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

222750 ZE 2: LSB participant address 27 reports an incorrect sensor type X635B:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

222751 ZE 2: LSB participant address 27 was not configured for the block transfer X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

222753 ZE 2: LSB participant address 27 no longer reports or withdrawn during running period X635B:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

222754 ZE 2: LSB participant address 27 Features other settings (parameters) as pre-entered set values X635B:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

222764 ZE 2: LSB participant address 27 reports tolerable error in self-test X635B:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

070645 157
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

222765 ZE 2: LSB participant address 27 reports intolerable error in self-test X635B:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

222766 ZE 2: LSB participant address 27 with software version, that is no longer compatible X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

222767 ZE 2: LSB participant address 27 supports no download function X635B:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

222804 ZE 2: LSB participant address 28 level exceeded X635B:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

222805 ZE 2: LSB participant address 28 below minimum level X635B:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

222818 ZE 2: LSB participant address 28 excess temperature X635B:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

222850 ZE 2: LSB participant address 28 reports an incorrect sensor type X635B:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

222851 ZE 2: LSB participant address 28 was not configured for the block transfer X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

222853 ZE 2: LSB participant address 28 no longer reports or withdrawn during running period X635B:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

222854 ZE 2: LSB participant address 28 Features other settings (parameters) as pre-entered set values X635B:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

070645 158
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

222864 ZE 2: LSB participant address 28 reports tolerable error in self-test X635B:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

222865 ZE 2: LSB participant address 28 reports intolerable error in self-test X635B:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

222866 ZE 2: LSB participant address 28 with software version, that is no longer compatible X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

222867 ZE 2: LSB participant address 28 supports no download function X635B:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

222904 ZE 2: LSB participant address 29 level exceeded X635B:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

222905 ZE 2: LSB participant address 29 below minimum level X635B:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

222918 ZE 2: LSB participant address 29 excess temperature X635B:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

222950 ZE 2: LSB participant address 29 reports an incorrect sensor type X635B:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

222951 ZE 2: LSB participant address 29 was not configured for the block transfer X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

222953 ZE 2: LSB participant address 29 no longer reports or withdrawn during running period X635B:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

070645 159
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

222954 ZE 2: LSB participant address 29 Features other settings (parameters) as pre-entered set values X635B:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

222964 ZE 2: LSB participant address 29 reports tolerable error in self-test X635B:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

222965 ZE 2: LSB participant address 29 reports intolerable error in self-test X635B:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

222966 ZE 2: LSB participant address 29 with software version, that is no longer compatible X635B:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

222967 ZE 2: LSB participant address 29 supports no download function X635B:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

223252 ZE 2: Control data transfer LSB has recognised Bus collisions, communication interrupted X635B:z14/z16 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor

223255 ZE 2: Control data transfer LSB Bus connection faulty/defect, short circuit to supply voltage X635B:z14/z16 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

223256 ZE 2: Control data transfer LSB Bus connection faulty/defect, no supply/short circuit to earth X635B:z14/z16 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

223257 ZE 2: Control data transfer LSB has recognised network re-set (data transfer starts again) X635B:z14/z16 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part

223258 ZE 2: Control data transfer LSB recognised participant with incorrect baud rate in bus X635B:z14/z16 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors

070645 160
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

223259 ZE 2: Control data transfer LSB recognised communication breakdown in bus X635B:z14/z16 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network

223260 ZE 2: Control data transfer LSB driver error: no order to carry out X635B:z14/z16 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software

223261 ZE 2: Control data transfer LSB driver error: undefined message appears X635B:z14/z16 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination

223262 ZE 2: Control data transfer LSB Driver error: Initialization error X635B:z14/z16 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination

225702 ZE 2: input 9 sensor deficiency data short circuit to supply voltage X635B:d20 E 1
report of error, otherwise no reaction
check supply, LICCON input, sensor lines to short or break, sensor

230500 ZE 2: remote control transmit, maximum transmission cycle radio contact exceeded E 1
radio control deactivated
check radio receiver/-transmitter (battery!)

230501 ZE 2: remote control receive, disrupted connection to receiver/interrupted E 1


radio control deactivated
check serial connection line to radio receiver

230502 ZE 2: remote control receive, transmission error (CRC) E 1


radio control temporarily deactivated
check serial connection line to radio receiver and radio receiver/ -transmitter

230503 ZE 2: remote control receive, transmission cycle mark exceeded E 1


radio control temporarily deactivated
check serial connection line to radio receiver and radio receiver/ -transmitter

230504 ZE 2: remote control receive, transmission cycle message exceeded E 1


radio control temporarily deactivated
check serial connection line to radio receiver and radio receiver/ -transmitter

070645 161
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

232000 ZE 2: control winch 1 no slewing movement recognized on actuated winch E 1


output of error
check LICCON output, lines for short or break, incremental sensor on function, hoisting gear brake

232002 ZE 2: control winch 1 hydraulic circuit pressure sensor defective/missing E 1


Output of error
check connection, if connection OK then replace sensor

233900 ZE 2: crane control signal engine speed defective/missing E 1


output of error, a medium speed will now be adjusted for the output limitation
check engine electronics, with permanent error contact after-sales service

233901 ZE 2: crane control Signal current engine momentum - Maximum erroneous / missing E 1
output of error, a medium torque will now be adjusted for the output limitation
check engine electronics, with permanent error contact after-sales service

234801 ZE 2: control diagnosis system tele angle sensor defective/missing E 1


Carrying out of test program delayed / interrupted
Check angle transmitter and connection, carry out test program again

234802 ZE 2: control diagnosis system winch incremental sensor defective/missing E 1


Carrying out of test program delayed / interrupted
Check incremental sensor winch, carry out test program again

234804 ZE 2: control diagnosis system end of stroke switch defective/missing E 1


Carrying out of test program delayed / interrupted
Check hoist limit switch and connection, lower hoist gear, carry out test program again

234805 ZE 2: control diagnosis system longitudinal sensor defective/missing E 1


Carrying out of test program delayed / interrupted
Check length indicator and connection, carry out test program again

234823 ZE 2: control diagnosis system pressure value in hoisting gear defective/missing E 1


Carrying out of test program delayed / interrupted
Adjust pressure, carry out test program again

234824 ZE 2: control diagnosis system Charge press. hoist gear or press. switch'Lower freely'faulty/not pre E 1
Carrying out of test program delayed / interrupted
Check charge pressure, carry out test program again

070645 162
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

234830 ZE 2: control diagnosis system Pressure cut-off pump outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check pressure reduction and pressure limitation LS, carry out test program again

234831 ZE 2: control diagnosis system Pressure cut-off hoist gear lift outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check pressure hoist gear, carry out test program again

234832 ZE 2: control diagnosis system Pressure cut-off hoist gear lower outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check pressure hoist gear, carry out test program again

234845 ZE 2: control diagnosis system Winch turns with no brake selected E 1


Carrying out of test program delayed / interrupted
Check hoist gear brake, carry out test program again

234846 ZE 2: control diagnosis system Initial current winch lift above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

234847 ZE 2: control diagnosis system Initial current winch lift below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

234848 ZE 2: control diagnosis system Initial current winch lower above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

234849 ZE 2: control diagnosis system Initial current winch lower below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

234850 ZE 2: control diagnosis system winch speed hoisting too high E 1


Carrying out of test program delayed / interrupted
Check valve / pump / pressure

234851 ZE 2: control diagnosis system winch speed hoisting too low E 1


Carrying out of test program delayed / interrupted
Check valve / pump / pressure

070645 163
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

234852 ZE 2: control diagnosis system winch speed lowering too low E 1


Carrying out of test program delayed / interrupted
Check valve / pump / pressure

234853 ZE 2: control diagnosis system winch speed lowering too high E 1


Carrying out of test program delayed / interrupted
Check valve / pump / pressure

234854 ZE 2: control diagnosis system Hysteresis winch lift too great


Carrying out of test program delayed / interrupted
Check proportional-flow valve

234855 ZE 2: control diagnosis system Hysteresis winch lower too great


Carrying out of test program delayed / interrupted
Check proportional-flow valve

235001 ZE 2: operation winch 1 feed pressure supply missing/too low B


Operation conditional switch off, may not be shunted
Reestablish charge pressure supply - shut-down may not be shunted

235004 ZE 2: operation winch 1 unreeled winch shut-down B


Operation conditional switch off, may not be shunted
reel in winch until the "winch reeled out" switch is no longer actuated - shut-down cannot be shunted

235005 ZE 2: operation winch 1 reeled winch shut-down B


Operation conditional switch off, may not be shunted
reel out winch until the "winch reeled in" switch is no longer actuated -shut-down cannot be shunted

235019 ZE 2: operation winch 1 no or invalid operation mode shut-down B


Operation conditional switch off, may not be shunted
enter correct operation mode or dismantle accessory parts - shut-down cannot be shunted

235020 ZE 2: operation winch 1 LMB shut-down B


operational shut down
Remedy cause of "LMB Stop" see error report LMB - shut-down may be shunted via assembly switch (danger).

235029 ZE 2: operation winch 1 winch blocked (C-key monitor) B


Operation conditional switch off, may not be shunted
Authorise winch 1 in control diagram

070645 164
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

235030 ZE 2: operation winch 1 master switch 1 defective/missing B


operational shut down
Turn master switch to zero position. Otherwise note system error for defective or missing sensors.

235031 ZE 2: operation winch 1 master switch 2 defective/missing B


operational shut down
Turn master switch to zero position. Otherwise note system error for defective or missing sensors.

235039 ZE 2: operation winch 1 seat contact shut-down B


operational shut down
Sit down or actuate one of the shunting switches for the seat contact in the master switches.

235044 ZE 2: operation winch 1 Shut-off crane engine not running B

235049 ZE 2: operation winch 1 Shut-down hoist limit switch 4 B


operational shut down
control winch in opposite direction until end stroke switch no longer active - shut-down can be shunted (danger)

235050 ZE 2: operation winch 1 end of stroke switch shut-down 1 B


operational shut down
control winch in opposite direction until end stroke switch no longer active - shut-down can be shunted (danger)

235051 ZE 2: operation winch 1 end of stroke switch shut-down 2 B


operational shut down
control winch in opposite direction until end stroke switch no longer active - shut-down can be shunted (danger)

235052 ZE 2: operation winch 1 end of stroke switch shut-down 3 B


operational shut down
control winch in opposite direction until end stroke switch no longer active - shut-down can be shunted (danger)

235081 ZE 2: operation winch 1 end of stroke switch 1 shut-down defective B


operational shut down
Error remedying see corresponding system error - shut-down may be shunted (danger)

235082 ZE 2: operation winch 1 end of stroke switch 2 shut-down defective B


operational shut down
Error remedying see corresponding system error - shut-down may be shunted (danger)

070645 165
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

235083 ZE 2: operation winch 1 end of stroke switch 3 shut-down defective B


operational shut down
Error remedying see corresponding system error - shut-down may be shunted (danger)

235089 ZE 2: operation winch 1 Shut-down hoist limit switch 4 faulty B


operational shut down
Error remedying see corresponding system error - shut-down may be shunted (danger)

236100 ZE 2: Operation ballasting / counterweight carriage Counterweight UP selected, final position not started B 1
report of error, otherwise no reaction
Approach end position, if ok check: -supply, -input LICCON, -sensor line for short-circuit or interruption, -

236101 ZE 2: Operation ballasting / counterweight carriage Counterweight DOWN selected, final position not started B 1
report of error, otherwise no reaction
Approach end position, if ok check: -supply, -input LICCON, -sensor line for short-circuit or interruption, -

236144 ZE 2: Operation ballasting / counterweight carriage Shut-off crane engine not running B

237200 ZE 2: operation instruments armrest right master switch 1Y not in neutral when starting B 1
output of error, shut-down through application
release master switch briefly or check LICCON input, gear lines, sensor

237201 ZE 2: operation instruments armrest right master switch 1X not in neutral when starting B 1
output of error, shut-down through application
release master switch briefly or check LICCON input, gear lines, sensor

237312 ZE 2: operation instruments armrest left master switch 2Y not in neutral when starting B 1
output of error, shut-down through application
release master switch briefly or check LICCON input, gear lines, sensor

239800 ZE 2: operation diagnosis system interruption, master switch defective or incorrectly deflected B 1
Carrying out of test program delayed / interrupted
Note direction of movements, carry out test program again

239801 ZE 2: operation diagnosis system interruption, master switch defective/missing B 1


Carrying out of test program delayed / interrupted
Check master switch, carry out test program again

070645 166
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

239802 ZE 2: operation diagnosis system interruption, incorrect or no operation mode B 1


Carrying out of test program delayed / interrupted
Set correct operation type, if necessary dismantle accessory, carry out test program again

239814 ZE 2: operation diagnosis system Alignment aid not correctly shut down B 1
Invalid operation condition, no proper crane operation possible
Apply F key, end active test program

239820 ZE 2: operation diagnosis system interruption, boom angle beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Extend to correct luffing position, carry out test program again

239821 ZE 2: operation diagnosis system interruption, tele length beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Extend to correct telescopic boom length length, carry out test program again

239822 ZE 2: operation diagnosis system interruption, hook load beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Note max. hook load, carry out test program again

239823 ZE 2: operation diagnosis system interruption, incorrect reeving B 1


Carrying out of test program delayed / interrupted
Note lowest amount of reevings, carry out test program again

239824 ZE 2: operation diagnosis system interruption, end of stroke switch activated/defective/missing B 1


Carrying out of test program delayed / interrupted
Check hoist limit switch, carry out test program again

261001 E/A-Modul 2: system error OS-C167 initialising error processor-register erroneous E 2


error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

261002 E/A-Modul 2: system error OS-C167 initialising error test total in EPROM/FLASH erroneous E 2
error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

261006 E/A-Modul 2: system error OS-C167 initialising error RAM erroneous E 2


error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

070645 167
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

261013 E/A-Modul 2: system error OS-C167 test total in EPROM/FLASH erroneous E 2


error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

261016 E/A-Modul 2: system error OS-C167 system-, driver-watchdog expired E 2


error indication on display
note error report, ignition ON/OFF, with repeated occurrence --> inform after-sales service

261068 E/A-Modul 2: system error OS-C167 impermissible interrupt E 2


error indication on display
note error report, ignition ON/OFF, with repeated occurrence --> inform after-sales service

261071 E/A-Modul 2: system error OS-C167 Invalid configuration or Firmware E 2


error indication on display
re-load Software from ZE

261080 E/A-Modul 2: system error OS-C167 fatal internal software error E 2


error indication on display
note error report, ignition ON/OFF, with repeated occurrence --> inform after-sales service

261082 E/A-Modul 2: system error OS-C167 hardware-watchdog erroneous E 2


error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

261088 E/A-Modul 2: system error OS-C167 Configuration does not match software condition E 1
Error output, possible error functions of module
Carry out EAM-download from LICCON

261089 E/A-Modul 2: system error OS-C167 Incorrect version of firmware installed E 1


Error output, possible error functions of module
Replace module, reload firmware

261090 E/A-Modul 2: system error OS-C167 Incorrect hardware version recognised E 1


Error output, possible error functions of module
Replace module

272052 E/A-Modul 2: input/output DEA0 output open, to low load, short circuit to supply voltage X623:17 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

070645 168
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

272053 E/A-Modul 2: input/output DEA0 transistor current supply insufficient or missing X623:17 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

272054 E/A-Modul 2: input/output DEA0 short circuit to supply voltage X623:17 E 1


error report on display
check output for short, if necessary replace E/A-Modul

272055 E/A-Modul 2: input/output DEA0 excessive temperature, short circuit to ground or overload X623:17 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

272152 E/A-Modul 2: input/output DEA1 output open, to low load, short circuit to supply voltage X623:15 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

272153 E/A-Modul 2: input/output DEA1 transistor current supply insufficient or missing X623:15 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

272154 E/A-Modul 2: input/output DEA1 short circuit to supply voltage X623:15 E 1


error report on display
check output for short, if necessary replace E/A-Modul

272155 E/A-Modul 2: input/output DEA1 excessive temperature, short circuit to ground or overload X623:15 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

272252 E/A-Modul 2: input/output DEA2 output open, to low load, short circuit to supply voltage X623:13 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

272253 E/A-Modul 2: input/output DEA2 transistor current supply insufficient or missing X623:13 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

272254 E/A-Modul 2: input/output DEA2 short circuit to supply voltage X623:13 E 1


error report on display
check output for short, if necessary replace E/A-Modul

070645 169
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

272255 E/A-Modul 2: input/output DEA2 excessive temperature, short circuit to ground or overload X623:13 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

272352 E/A-Modul 2: input/output DEA3 output open, to low load, short circuit to supply voltage X623:11 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

272353 E/A-Modul 2: input/output DEA3 transistor current supply insufficient or missing X623:11 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

272354 E/A-Modul 2: input/output DEA3 short circuit to supply voltage X623:11 E 1


error report on display
check output for short, if necessary replace E/A-Modul

272355 E/A-Modul 2: input/output DEA3 excessive temperature, short circuit to ground or overload X623:11 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

272452 E/A-Modul 2: input/output DEA4 output open, to low load, short circuit to supply voltage X623:9 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

272453 E/A-Modul 2: input/output DEA4 transistor current supply insufficient or missing X623:9 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

272454 E/A-Modul 2: input/output DEA4 short circuit to supply voltage X623:9 E 1


error report on display
check output for short, if necessary replace E/A-Modul

272455 E/A-Modul 2: input/output DEA4 excessive temperature, short circuit to ground or overload X623:9 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

272552 E/A-Modul 2: input/output DEA5 output open, to low load, short circuit to supply voltage X623:7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

070645 170
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

272553 E/A-Modul 2: input/output DEA5 transistor current supply insufficient or missing X623:7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

272554 E/A-Modul 2: input/output DEA5 short circuit to supply voltage X623:7 E 1


error report on display
check output for short, if necessary replace E/A-Modul

272555 E/A-Modul 2: input/output DEA5 excessive temperature, short circuit to ground or overload X623:7 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

272652 E/A-Modul 2: input/output DEA6 output open, to low load, short circuit to supply voltage X623:5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

272653 E/A-Modul 2: input/output DEA6 transistor current supply insufficient or missing X623:5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

272654 E/A-Modul 2: input/output DEA6 short circuit to supply voltage X623:5 E 1


error report on display
check output for short, if necessary replace E/A-Modul

272655 E/A-Modul 2: input/output DEA6 excessive temperature, short circuit to ground or overload X623:5 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

272752 E/A-Modul 2: input/output DEA7 output open, to low load, short circuit to supply voltage X623:3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

272753 E/A-Modul 2: input/output DEA7 transistor current supply insufficient or missing X623:3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

272754 E/A-Modul 2: input/output DEA7 short circuit to supply voltage X623:3 E 1


error report on display
check output for short, if necessary replace E/A-Modul

070645 171
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

272755 E/A-Modul 2: input/output DEA7 excessive temperature, short circuit to ground or overload X623:3 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

273481 E/A-Modul 2: voltage input E4 short circuit to supply voltage, open line X622:9 E 1
symbol for compressed air supply 1 is flashing on the display unit
check input signal on the E/A-Modul or sensor

273581 E/A-Modul 2: voltage input E5 short circuit to supply voltage, open line X622:7 E 1
symbol for compressed air supply 2 is flashing on the display unit
check input signal on the E/A-Modul or sensor

273681 E/A-Modul 2: voltage input E6 short circuit to supply voltage, open line X622:5 E 1
symbol for compressed air supply 3 is flashing on the display unit
check input signal on the E/A-Modul or sensor

273782 E/A-Modul 2: voltage input E7 short circuit to ground, open line, constant current 10 mA incorrect X622:3 E 1
no reaction
check input signal on the E/A-Modul or sensor

273783 E/A-Modul 2: voltage input E7 short circuit to supply voltage, open line, lack of voltage X622:3 E 1
no reaction
check input signal on the E/A-Modul or sensor

279052 E/A-Modul 2: output A0 output open, to low load, short circuit to supply voltage X623:18 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

279053 E/A-Modul 2: output A0 transistor current supply insufficient or missing X623:18 E 1


error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

279054 E/A-Modul 2: output A0 short circuit to supply voltage X623:18 E 1


error report on display
check output for short, if necessary replace E/A-Modul

279055 E/A-Modul 2: output A0 excessive temperature, short circuit to ground or overload X623:18 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

070645 172
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

279152 E/A-Modul 2: output A1 output open, to low load, short circuit to supply voltage X623:16 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

279153 E/A-Modul 2: output A1 transistor current supply insufficient or missing X623:16 E 1


error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

279154 E/A-Modul 2: output A1 short circuit to supply voltage X623:16 E 1


error report on display
check output for short, if necessary replace E/A-Modul

279155 E/A-Modul 2: output A1 excessive temperature, short circuit to ground or overload X623:16 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

279250 E/A-Modul 2: bridge output A2 short circuit to ground, junction not supplied X623:14 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul

279251 E/A-Modul 2: bridge output A2 short circuit to supply voltage, excessive temperature X623:14 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul

279252 E/A-Modul 2: bridge output A2 output open, to low load, short circuit to supply voltage X623:14 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

279253 E/A-Modul 2: bridge output A2 transistor current supply insufficient or missing X623:14 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

279254 E/A-Modul 2: bridge output A2 short circuit to supply voltage X623:14 E 1


error report on display
check output for short, if necessary replace E/A-Modul

279255 E/A-Modul 2: bridge output A2 excessive temperature, short circuit to ground or overload X623:14 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

070645 173
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

279350 E/A-Modul 2: bridge output A3 short circuit to ground, junction not supplied X623:12 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul

279351 E/A-Modul 2: bridge output A3 short circuit to supply voltage, excessive temperature X623:12 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul

279352 E/A-Modul 2: bridge output A3 output open, to low load, short circuit to supply voltage X623:12 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

279353 E/A-Modul 2: bridge output A3 transistor current supply insufficient or missing X623:12 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

279354 E/A-Modul 2: bridge output A3 short circuit to supply voltage X623:12 E 1


error report on display
check output for short, if necessary replace E/A-Modul

279355 E/A-Modul 2: bridge output A3 excessive temperature, short circuit to ground or overload X623:12 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

283301 E/A-Modul 2: SPI-display unit Faulty data transfer E/A-module<>unit (time exceeded) X624:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul

283302 E/A-Modul 2: SPI-display unit Serious system error to SPI-connection (interface) X624:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul

283303 E/A-Modul 2: SPI-display unit break in line or short circuit to supply voltage X624:1/2/3/5/6/ E 1
error indication on display 7/8
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary

283304 E/A-Modul 2: SPI-display unit break in line or short circuit to ground X624:1/2/3/5/6/ E 1
error indication on display 7/8
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary

070645 174
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

283306 E/A-Modul 2: SPI-display unit Data transfer faulty (faulty check byte) X624:1/2/3/5/6/ E 1
error indication on display 7/8
suppress EMV- interference

283307 E/A-Modul 2: SPI-display unit Unit faulty/missing, incorrect unit inserted (ID) X624:1/2/3/5/6/ E 1
error indication on display 7/8
check periphery and replace if necessary, check Software version, check EMV- interference

283308 E/A-Modul 2: SPI-display unit Data transfer faulty (incorrect number of data bytes received) X624:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul

283900 E/A-Modul 2: Control operating unit (SPI) Faulty initialisation data connection E/A-module<>unit X624:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul

283902 E/A-Modul 2: Control operating unit (SPI) Serious system error to SPI-connection (interface) X624:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul

283905 E/A-Modul 2: Control operating unit (SPI) Initialisation error, resetting inputs/outputs faulty X624:1/2/3/5/6/ E 1
error indication on display 7/8
check wiring, check periphery and replace if necessary, check E/A-Modul and replace if necessary

283907 E/A-Modul 2: Control operating unit (SPI) Unit faulty/missing, incorrect unit inserted (ID) X624:1/2/3/5/6/ E 1
error indication on display 7/8
connect functional periphery unit, system then eliminates error independently

283908 E/A-Modul 2: Control operating unit (SPI) Data transfer faulty (incorrect number of data bytes received) X624:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul

284104 E/A-Modul 2: LSB-B participant address 1 level exceeded X623:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

284105 E/A-Modul 2: LSB-B participant address 1 below minimum level X623:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

070645 175
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

284118 E/A-Modul 2: LSB-B participant address 1 excess temperature X623:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

284150 E/A-Modul 2: LSB-B participant address 1 reports an incorrect sensor type X623:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

284151 E/A-Modul 2: LSB-B participant address 1 was not configured for the block transfer X623:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

284153 E/A-Modul 2: LSB-B participant address 1 no longer reports or withdrawn during running period X623:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

284154 E/A-Modul 2: LSB-B participant address 1 Features other settings (parameters) as pre-entered set values X623:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

284164 E/A-Modul 2: LSB-B participant address 1 reports tolerable error in self-test X623:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

284165 E/A-Modul 2: LSB-B participant address 1 reports intolerable error in self-test X623:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

284166 E/A-Modul 2: LSB-B participant address 1 with software version, that is no longer compatible X623:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

284167 E/A-Modul 2: LSB-B participant address 1 supports no download function X623:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

284204 E/A-Modul 2: LSB-B participant address 2 level exceeded X623:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

070645 176
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

284205 E/A-Modul 2: LSB-B participant address 2 below minimum level X623:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

284218 E/A-Modul 2: LSB-B participant address 2 excess temperature X623:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

284250 E/A-Modul 2: LSB-B participant address 2 reports an incorrect sensor type X623:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

284251 E/A-Modul 2: LSB-B participant address 2 was not configured for the block transfer X623:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

284253 E/A-Modul 2: LSB-B participant address 2 no longer reports or withdrawn during running period X623:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

284254 E/A-Modul 2: LSB-B participant address 2 Features other settings (parameters) as pre-entered set values X623:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

284264 E/A-Modul 2: LSB-B participant address 2 reports tolerable error in self-test X623:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

284265 E/A-Modul 2: LSB-B participant address 2 reports intolerable error in self-test X623:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

284266 E/A-Modul 2: LSB-B participant address 2 with software version, that is no longer compatible X623:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

284267 E/A-Modul 2: LSB-B participant address 2 supports no download function X623:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

070645 177
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

284304 E/A-Modul 2: LSB-B participant address 3 level exceeded X623:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

284305 E/A-Modul 2: LSB-B participant address 3 below minimum level X623:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

284318 E/A-Modul 2: LSB-B participant address 3 excess temperature X623:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

284350 E/A-Modul 2: LSB-B participant address 3 reports an incorrect sensor type X623:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

284351 E/A-Modul 2: LSB-B participant address 3 was not configured for the block transfer X623:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

284353 E/A-Modul 2: LSB-B participant address 3 no longer reports or withdrawn during running period X623:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

284354 E/A-Modul 2: LSB-B participant address 3 Features other settings (parameters) as pre-entered set values X623:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

284364 E/A-Modul 2: LSB-B participant address 3 reports tolerable error in self-test X623:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

284365 E/A-Modul 2: LSB-B participant address 3 reports intolerable error in self-test X623:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

284366 E/A-Modul 2: LSB-B participant address 3 with software version, that is no longer compatible X623:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

070645 178
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

284367 E/A-Modul 2: LSB-B participant address 3 supports no download function X623:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

284404 E/A-Modul 2: LSB-B participant address 4 level exceeded X623:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

284405 E/A-Modul 2: LSB-B participant address 4 below minimum level X623:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

284418 E/A-Modul 2: LSB-B participant address 4 excess temperature X623:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

284450 E/A-Modul 2: LSB-B participant address 4 reports an incorrect sensor type X623:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

284451 E/A-Modul 2: LSB-B participant address 4 was not configured for the block transfer X623:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

284453 E/A-Modul 2: LSB-B participant address 4 no longer reports or withdrawn during running period X623:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

284454 E/A-Modul 2: LSB-B participant address 4 Features other settings (parameters) as pre-entered set values X623:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

284464 E/A-Modul 2: LSB-B participant address 4 reports tolerable error in self-test X623:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

284465 E/A-Modul 2: LSB-B participant address 4 reports intolerable error in self-test X623:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

070645 179
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

284466 E/A-Modul 2: LSB-B participant address 4 with software version, that is no longer compatible X623:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

284467 E/A-Modul 2: LSB-B participant address 4 supports no download function X623:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

284504 E/A-Modul 2: LSB-B participant address 5 level exceeded X623:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

284505 E/A-Modul 2: LSB-B participant address 5 below minimum level X623:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

284518 E/A-Modul 2: LSB-B participant address 5 excess temperature X623:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

284550 E/A-Modul 2: LSB-B participant address 5 reports an incorrect sensor type X623:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

284551 E/A-Modul 2: LSB-B participant address 5 was not configured for the block transfer X623:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

284553 E/A-Modul 2: LSB-B participant address 5 no longer reports or withdrawn during running period X623:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

284554 E/A-Modul 2: LSB-B participant address 5 Features other settings (parameters) as pre-entered set values X623:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

284564 E/A-Modul 2: LSB-B participant address 5 reports tolerable error in self-test X623:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

070645 180
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

284565 E/A-Modul 2: LSB-B participant address 5 reports intolerable error in self-test X623:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

284566 E/A-Modul 2: LSB-B participant address 5 with software version, that is no longer compatible X623:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

284567 E/A-Modul 2: LSB-B participant address 5 supports no download function X623:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

284604 E/A-Modul 2: LSB-B participant address 6 level exceeded X623:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

284605 E/A-Modul 2: LSB-B participant address 6 below minimum level X623:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

284618 E/A-Modul 2: LSB-B participant address 6 excess temperature X623:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

284650 E/A-Modul 2: LSB-B participant address 6 reports an incorrect sensor type X623:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

284651 E/A-Modul 2: LSB-B participant address 6 was not configured for the block transfer X623:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

284653 E/A-Modul 2: LSB-B participant address 6 no longer reports or withdrawn during running period X623:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

284654 E/A-Modul 2: LSB-B participant address 6 Features other settings (parameters) as pre-entered set values X623:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

070645 181
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

284664 E/A-Modul 2: LSB-B participant address 6 reports tolerable error in self-test X623:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

284665 E/A-Modul 2: LSB-B participant address 6 reports intolerable error in self-test X623:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

284666 E/A-Modul 2: LSB-B participant address 6 with software version, that is no longer compatible X623:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

284667 E/A-Modul 2: LSB-B participant address 6 supports no download function X623:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

286604 E/A-Modul 2: LSB-B participant address 26 level exceeded X623:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

286605 E/A-Modul 2: LSB-B participant address 26 below minimum level X623:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

286618 E/A-Modul 2: LSB-B participant address 26 excess temperature X623:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

286650 E/A-Modul 2: LSB-B participant address 26 reports an incorrect sensor type X623:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

286651 E/A-Modul 2: LSB-B participant address 26 was not configured for the block transfer X623:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

286653 E/A-Modul 2: LSB-B participant address 26 no longer reports or withdrawn during running period X623:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

070645 182
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

286654 E/A-Modul 2: LSB-B participant address 26 Features other settings (parameters) as pre-entered set values X623:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

286664 E/A-Modul 2: LSB-B participant address 26 reports tolerable error in self-test X623:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

286665 E/A-Modul 2: LSB-B participant address 26 reports intolerable error in self-test X623:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

286666 E/A-Modul 2: LSB-B participant address 26 with software version, that is no longer compatible X623:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

286667 E/A-Modul 2: LSB-B participant address 26 supports no download function X623:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

286704 E/A-Modul 2: LSB-B participant address 27 level exceeded X623:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

286705 E/A-Modul 2: LSB-B participant address 27 below minimum level X623:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

286718 E/A-Modul 2: LSB-B participant address 27 excess temperature X623:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

286750 E/A-Modul 2: LSB-B participant address 27 reports an incorrect sensor type X623:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

286751 E/A-Modul 2: LSB-B participant address 27 was not configured for the block transfer X623:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

070645 183
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

286753 E/A-Modul 2: LSB-B participant address 27 no longer reports or withdrawn during running period X623:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

286754 E/A-Modul 2: LSB-B participant address 27 Features other settings (parameters) as pre-entered set values X623:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

286764 E/A-Modul 2: LSB-B participant address 27 reports tolerable error in self-test X623:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

286765 E/A-Modul 2: LSB-B participant address 27 reports intolerable error in self-test X623:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

286766 E/A-Modul 2: LSB-B participant address 27 with software version, that is no longer compatible X623:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

286767 E/A-Modul 2: LSB-B participant address 27 supports no download function X623:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

286804 E/A-Modul 2: LSB-B participant address 28 level exceeded X623:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

286805 E/A-Modul 2: LSB-B participant address 28 below minimum level X623:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

286818 E/A-Modul 2: LSB-B participant address 28 excess temperature X623:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

286850 E/A-Modul 2: LSB-B participant address 28 reports an incorrect sensor type X623:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

070645 184
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

286851 E/A-Modul 2: LSB-B participant address 28 was not configured for the block transfer X623:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

286853 E/A-Modul 2: LSB-B participant address 28 no longer reports or withdrawn during running period X623:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

286854 E/A-Modul 2: LSB-B participant address 28 Features other settings (parameters) as pre-entered set values X623:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

286864 E/A-Modul 2: LSB-B participant address 28 reports tolerable error in self-test X623:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

286865 E/A-Modul 2: LSB-B participant address 28 reports intolerable error in self-test X623:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

286866 E/A-Modul 2: LSB-B participant address 28 with software version, that is no longer compatible X623:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

286867 E/A-Modul 2: LSB-B participant address 28 supports no download function X623:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

286904 E/A-Modul 2: LSB-B participant address 29 level exceeded X623:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

286905 E/A-Modul 2: LSB-B participant address 29 below minimum level X623:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

286918 E/A-Modul 2: LSB-B participant address 29 excess temperature X623:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

070645 185
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

286950 E/A-Modul 2: LSB-B participant address 29 reports an incorrect sensor type X623:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

286951 E/A-Modul 2: LSB-B participant address 29 was not configured for the block transfer X623:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

286953 E/A-Modul 2: LSB-B participant address 29 no longer reports or withdrawn during running period X623:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

286954 E/A-Modul 2: LSB-B participant address 29 Features other settings (parameters) as pre-entered set values X623:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

286964 E/A-Modul 2: LSB-B participant address 29 reports tolerable error in self-test X623:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

286965 E/A-Modul 2: LSB-B participant address 29 reports intolerable error in self-test X623:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

286966 E/A-Modul 2: LSB-B participant address 29 with software version, that is no longer compatible X623:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

286967 E/A-Modul 2: LSB-B participant address 29 supports no download function X623:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

287252 E/A-Modul 2: Control data transfer LSB-B has recognised Bus collisions, communication interrupted X623:4/6 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor

287255 E/A-Modul 2: Control data transfer LSB-B Bus connection faulty/defect, short circuit to supply voltage X623:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

070645 186
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

287256 E/A-Modul 2: Control data transfer LSB-B Bus connection faulty/defect, no supply/short circuit to earth X623:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

287257 E/A-Modul 2: Control data transfer LSB-B has recognised network re-set (data transfer starts again) X623:4/6 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part

287258 E/A-Modul 2: Control data transfer LSB-B recognised participant with incorrect baud rate in bus X623:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors

287259 E/A-Modul 2: Control data transfer LSB-B recognised communication breakdown in bus X623:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network

287260 E/A-Modul 2: Control data transfer LSB-B driver error: no order to carry out X623:4/6 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software

287261 E/A-Modul 2: Control data transfer LSB-B driver error: undefined message appears X623:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination

287262 E/A-Modul 2: Control data transfer LSB-B Driver error: Initialization error X623:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination

287530 E/A-Modul 2: CAN-participant engine Data transfer subscriber transfer cycle exceeded X625:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant

287531 E/A-Modul 2: CAN-participant engine Data transfer faulty/missing, max. cycle time exceeded X625:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant

287630 E/A-Modul 2: CAN-participant gear Data transfer subscriber transfer cycle exceeded X625:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul

070645 187
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

287631 E/A-Modul 2: CAN-participant gear Data transfer faulty/missing, max. cycle time exceeded X625:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

287730 E/A-Modul 2: CAN-participant ABV (ABS/ASR) Data transfer subscriber transfer cycle exceeded X625:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul

287731 E/A-Modul 2: CAN-participant ABV (ABS/ASR) Data transfer faulty/missing, max. cycle time exceeded X625:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

287930 E/A-Modul 2: CAN-participant retarder Data transfer subscriber transfer cycle exceeded X625:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul

287931 E/A-Modul 2: CAN-participant retarder Data transfer faulty/missing, max. cycle time exceeded X625:5/6 E 1
parameterised substitute values for receiver signals will be used
Check CAN network, check faulty Bus user.

288030 E/A-Modul 2: CAN-user converter clutch unit CCU Data transfer subscriber transfer cycle exceeded X625:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul

288031 E/A-Modul 2: CAN-user converter clutch unit CCU Data transfer faulty/missing, max. cycle time exceeded X625:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

288530 E/A-Modul 2: CAN-participant E/A-Modul 1 Data transfer subscriber transfer cycle exceeded X625:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant

288531 E/A-Modul 2: CAN-participant E/A-Modul 1 Data transfer faulty/missing, max. cycle time exceeded X625:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

288630 E/A-Modul 2: CAN-participant E/A-Modul 2 Data transfer subscriber transfer cycle exceeded X625:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant

070645 188
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

288631 E/A-Modul 2: CAN-participant E/A-Modul 2 Data transfer faulty/missing, max. cycle time exceeded X625:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

288930 E/A-Modul 2: CAN-participant E/A-Modul 5 Data transfer subscriber transfer cycle exceeded X625:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant

288931 E/A-Modul 2: CAN-participant E/A-Modul 5 Data transfer faulty/missing, max. cycle time exceeded X625:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

289900 E/A-Modul 2: Control data transfer CAN internal error at Register-check Controller X625:5/6 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul

289901 E/A-Modul 2: Control data transfer CAN internal error at RAM-check Controller X625:5/6 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul

289902 E/A-Modul 2: Control data transfer CAN Configuration error Software X625:5/6 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul, check Software (test system ZE)

289903 E/A-Modul 2: Control data transfer CAN Transfer interrupted after continuous error X625:5/6 E 1
CAN-Transmission will be aborted
check bus lines/neutral point, replace neutral point or E/A-Modul

289910 E/A-Modul 2: Control data transfer CAN short-term error in bus connection X625:5/6 E 0
re-attachment of Modul to bus transmission
check bus lines/neutral point, unplug individual bus participant and check if error has been eliminated

289911 E/A-Modul 2: Control data transfer CAN permanent error bus connection X625:5/6 E 1
cyclic re-attachment of Modul to bus transmission
check bus lines/neutral point, unplug individual bus participant and check if error has been eliminated

289920 E/A-Modul 2: Control data transfer CAN active participant not responding X625:5/6 E 0
parameterised substitute values for receiver signals will be used
check error report for missing participant(s), test system ZE

070645 189
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

289921 E/A-Modul 2: Control data transfer CAN No active subscriber responding X625:5/6 E 1
parameterised substitute values for receiver signals will be used
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul

289950 E/A-Modul 2: Control data transfer CAN erroneous command test system X625:5/6 E 1
no reaction to unknown test system control command in CAN-System Software
check Software (test system)

292001 E/A-Modul 2: control engine long-term disruption E/A-Modul <-> engine control E 1
engine control and E/A-Modul at emergency speed
engine control and E/A-Modul, check CAN-bus-connections

293038 E/A-Modul 2: control hydraulic/second. power outputs feedback secondary output pump active missing E 1
in case the pump is mechanically engaged; operation is possible
check pneumatic engagement mechanism of pump, sensor position; if necessary engage by hand with engine off

293039 E/A-Modul 2: control hydraulic/second. power outputs feedback secondary output pump inactive missing E 1
in case the pump is mechanically engaged, pump can be damaged in travel operation due to excessive speed
pneumatic engagement mechanism of the pump, check sensor position; if nec. disengage pump manually with engine off

293500 E/A-Modul 2: control heating/air conditioning servo-motor heating, circulated/fresh air or screen/foot erroneous E 1
servo motor relays a high signal to the diagnosis output
check water valve and air flaps of the heating or check servo motor

294190 E/A-Modul 2: LSB-bus participant ZE missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

294191 E/A-Modul 2: LSB-bus participant E/A-Modul 1 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

294193 E/A-Modul 2: LSB-bus participant E/A-Modul 3 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

294194 E/A-Modul 2: LSB-bus participant E/A-Modul 4 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

070645 190
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

294195 E/A-Modul 2: LSB-bus participant E/A-Modul 5 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

294943 E/A-Modul 2: control optional device no signal from boom sensor in support E 1
control indicator for boom support flashing
check LSB-bus connection, check sensor

295050 E/A-Modul 2: operation engine no engine start possible as engine already recognized as ON B
function is not carried out

295055 E/A-Modul 2: operation engine STOP, ignition operators cab in upper-carriage operation mode B
function is not carried out

295056 E/A-Modul 2: operation engine STOP, ignition operators cab in under-carriage operation mode B
function is not carried out

295059 E/A-Modul 2: operation engine no start, CAN-connection E/A-Modul <-> engine elec. malfunc B
function is not carried out

295060 E/A-Modul 2: operation engine no start, gears not in N B


function is not carried out

295061 E/A-Modul 2: operation engine no start, no operation mode recognised B


function is not carried out

295062 E/A-Modul 2: operation engine no start, ignition upper/under-carriage switched on B


function is not carried out

295063 E/A-Modul 2: operation engine no start, engine-STOP-key activated in right support unit B
function is not carried out

070645 191
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

295064 E/A-Modul 2: operation engine no start, engine-STOP-key activated in left support unit B
function is not carried out

295065 E/A-Modul 2: operation engine no start, key activated in support unit B


function is not carried out

295079 E/A-Modul 2: operation engine support box-operation mode prevented: gears not in neutral B
function is not carried out

295080 E/A-Modul 2: operation engine travel operation not possible when key activated on support box B
function is not carried out

295500 E/A-Modul 2: operation axle suspension function simultaneously ON and OFF B


function is not carried out
do not simultaneously activate contrasting function keys

295511 E/A-Modul 2: operation axle suspension unauthorised switching on of function B


function is not carried out
start engine and repeat operation

295513 E/A-Modul 2: operation axle suspension unauthorised function activation B


function is not carried out
start engine and repeat operation

295900 E/A-Modul 2: operation longitudinal lock function simultaneously ON and OFF B


function is not carried out
do not simultaneously activate contrasting function keys

295911 E/A-Modul 2: operation longitudinal lock unauthorised switching on of function B


function is not carried out
start engine and repeat operation

295912 E/A-Modul 2: operation longitudinal lock unauthorised switching off of function B


function is not carried out
start engine and repeat operation

070645 192
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

295913 E/A-Modul 2: operation longitudinal lock unauthorised function activation B


function is not carried out
start engine and repeat operation

295914 E/A-Modul 2: operation longitudinal lock activation of function without operation mode B
function is not carried out
start engine and repeat operation

296660 E/A-Modul 2: operation hydraulics/second. power outputs secondary output pump not engaged as compr. air supply too low B
function is not carried out

296663 E/A-Modul 2: operation hydraulics/second. power outputs secondary output pump not switchable as engine ON B
function is not carried out

296666 E/A-Modul 2: operation hydraulics/second. power outputs hyd. crane system pump not engaged as compr. air supply too low B
function is not carried out

296777 E/A-Modul 2: operation off-road gear Clear distributor gear active or no report B
function is not carried out
do not disconnect transfer case in off-road gear ON or off-road gear not ON with disconnection of transfer gear

300001 ZE 3: system error OS-HC11 (observe parameters) initialising error processor-register erroneous E 2
no crane operation possible
if error re-occurs, then ZE should be replaced

300002 ZE 3: system error OS-HC11 (observe parameters) initialising error test total in EPROM/FLASH erroneous E 2
no crane operation possible
check program memory card or ZE

300006 ZE 3: system error OS-HC11 (observe parameters) initialising error RAM erroneous E 2
no crane operation possible
if error re-occurs, then ZE should be replaced

300007 ZE 3: system error OS-HC11 (observe parameters) UART erroneous E 2


no crane operation possible
if error re-occurs, then ZE should be replaced

070645 193
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

300010 ZE 3: system error OS-HC11 (observe parameters) system routine inaccessible E 2


entry in error memory, all crane movements will be stopped

300011 ZE 3: system error OS-HC11 (observe parameters) ZE-watchdog expired E 2


entry in error memory, all crane movements will be stopped
check ZE

300012 ZE 3: system error OS-HC11 (observe parameters) type-identification in EPROM erroneous E 2


entry in error memory, no crane operation possible
check program memory card

300013 ZE 3: system error OS-HC11 (observe parameters) Test sum in FLASH erroneous E 2
entry in error memory, all crane movements will be stopped
check program memory card

300014 ZE 3: system error OS-HC11 (observe parameters) program already running E 2


entry in error memory, all crane movements will be stopped

300015 ZE 3: system error OS-HC11 (observe parameters) program not available E 2


entry in error memory, all crane movements will be stopped

300016 ZE 3: system error OS-HC11 (observe parameters) system-, driver-watchdog expired E 2


entry in error memory, all crane movements will be stopped

300017 ZE 3: system error OS-HC11 (observe parameters) total of CPU-time distribution too great E 2
entry in error memory, all crane movements will be stopped

300018 ZE 3: system error OS-HC11 (observe parameters) arithmetic overflow (16 Bit) E 2
entry in error memory, all crane movements will be stopped

300019 ZE 3: system error OS-HC11 (observe parameters) division through zero (16 Bit) E 2
entry in error memory, all crane movements will be stopped

070645 194
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

300020 ZE 3: system error OS-HC11 (observe parameters) task-watchdog expired E 2


entry in error memory, all crane movements will be stopped

300021 ZE 3: system error OS-HC11 (observe parameters) illegal opcode trap E 2


entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

300022 ZE 3: system error OS-HC11 (observe parameters) task inactive E 2


entry in error memory, all crane movements will be stopped

300023 ZE 3: system error OS-HC11 (observe parameters) program incapable of running (type identification) E 2
entry in error memory, all crane movements will be stopped

300024 ZE 3: system error OS-HC11 (observe parameters) task already used E 2


entry in error memory, all crane movements will be stopped

300025 ZE 3: system error OS-HC11 (observe parameters) realtime-module already used E 2


entry in error memory, all crane movements will be stopped

300026 ZE 3: system error OS-HC11 (observe parameters) regulator-module already used E 2


entry in error memory, all crane movements will be stopped

300030 ZE 3: system error OS-HC11 (observe parameters) unacceptable bank address E 2


entry in error memory, all crane movements will be stopped

300041 ZE 3: system error OS-HC11 (observe parameters) arithmetic error E 2


entry in error memory, all crane movements will be stopped

300044 ZE 3: system error OS-HC11 (observe parameters) output parameter without effect, from inactive output E 2
entry in error memory, all crane movements will be stopped

070645 195
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

300045 ZE 3: system error OS-HC11 (observe parameters) entry parameter undefined, from inactive input E 2
entry in error memory, all crane movements will be stopped

300046 ZE 3: system error OS-HC11 (observe parameters) impermissible regulator parameter E 2


entry in error memory, all crane movements will be stopped

300047 ZE 3: system error OS-HC11 (observe parameters) realtime-control block not available E 2
entry in error memory, all crane movements will be stopped

300048 ZE 3: system error OS-HC11 (observe parameters) realtime-control block inactive E 2


entry in error memory, all crane movements will be stopped

300049 ZE 3: system error OS-HC11 (observe parameters) urgent modul, ZE not available E 2
entry in error memory, no crane operation possible
check ZE

300050 ZE 3: system error OS-HC11 (observe parameters) file not available E 2


entry in error memory, all crane movements will be stopped

300051 ZE 3: system error OS-HC11 (observe parameters) file already opened E 2


entry in error memory, all crane movements will be stopped

300052 ZE 3: system error OS-HC11 (observe parameters) file not open on close E 2
entry in error memory, all crane movements will be stopped

300053 ZE 3: system error OS-HC11 (observe parameters) system mask not available E 2
entry in error memory, all crane movements will be stopped

300054 ZE 3: system error OS-HC11 (observe parameters) system text not available E 2
entry in error memory, all crane movements will be stopped

070645 196
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

300055 ZE 3: system error OS-HC11 (observe parameters) symbol not available E 2


entry in error memory, all crane movements will be stopped

300056 ZE 3: system error OS-HC11 (observe parameters) invalid mark in symbol E 2


entry in error memory, all crane movements will be stopped

300057 ZE 3: system error OS-HC11 (observe parameters) default load chart missing E 2
entry in error memory, all crane movements will be stopped

300058 ZE 3: system error OS-HC11 (observe parameters) amplifier erroneous or return power feed E 2
entry in error memory, all crane movements will be stopped
check wiring

300059 ZE 3: system error OS-HC11 (observe parameters) subroutine not reenterant E 2


entry in error memory, all crane movements will be stopped

300060 ZE 3: system error OS-HC11 (observe parameters) transmission error SCI E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

300061 ZE 3: system error OS-HC11 (observe parameters) SCI-BREAK E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

300062 ZE 3: system error OS-HC11 (observe parameters) SCI not connected E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

300063 ZE 3: system error OS-HC11 (observe parameters) monitor error in operation E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

300065 ZE 3: system error OS-HC11 (observe parameters) impermissible bus address E 2


entry in error memory, all crane movements will be stopped

070645 197
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

300066 ZE 3: system error OS-HC11 (observe parameters) ADC working outside the permissible tolerance E 2
entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

300067 ZE 3: system error OS-HC11 (observe parameters) arithmetic processor not available E 2
entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

300068 ZE 3: system error OS-HC11 (observe parameters) impermissible interrupt E 2


entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

300070 ZE 3: system error OS-HC11 (observe parameters) various structure versions E 2


entry in error memory, no crane operation possible

300071 ZE 3: system error OS-HC11 (observe parameters) Structure file missing or faulty E 2
entry in error memory, no crane operation possible

300072 ZE 3: system error OS-HC11 (observe parameters) structure entry senseless E 2


entry in error memory, no crane operation possible

300073 ZE 3: system error OS-HC11 (observe parameters) interpreter error E 2


entry in error memory, all crane movements will be stopped

300074 ZE 3: system error OS-HC11 (observe parameters) transformation ASCII to BIN erroneous E 2
entry in error memory, all crane movements will be stopped

300075 ZE 3: system error OS-HC11 (observe parameters) SPI-error E 2


entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

300076 ZE 3: system error OS-HC11 (observe parameters) incorrectly inserted power unit E 2
entry in error memory, all crane movements will be stopped
check memory card in power supply unit

070645 198
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

300077 ZE 3: system error OS-HC11 (observe parameters) BAF-call-up erroneous E 2


entry in error memory, all crane movements will be stopped

300078 ZE 3: system error OS-HC11 (observe parameters) impermissible parameter E 2


entry in error memory, all crane movements will be stopped

300079 ZE 3: system error OS-HC11 (observe parameters) no right of access E 2


entry in error memory, all crane movements will be stopped

300080 ZE 3: system error OS-HC11 (observe parameters) Fatal internal error E 2


entry in error memory, all crane movements will be stopped

300081 ZE 3: system error OS-HC11 (observe parameters) stack overflow E 2


entry in error memory, all crane movements will be stopped

300082 ZE 3: system error OS-HC11 (observe parameters) hardware-watchdog erroneous E 2


entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

300094 ZE 3: system error OS-HC11 (observe parameters) transmission error parallel bus E 2
entry in error memory, all crane movements will be stopped
check ZE, bus circuit board, power supply unit

300095 ZE 3: system error OS-HC11 (observe parameters) DMA-error E 2


entry in error memory, all crane movements will be stopped
check ZE, bus circuit board, power supply unit

300099 ZE 3: system error OS-HC11 (observe parameters) DSP0 erroneous E 2


entry in error memory, all crane movements will be stopped
if error re-occurs, then ZE should be replaced

302001 ZE 3: system error OS-TMS initialising error processor-register erroneous E 2


entry of error in error memory, all crane movements will be stopped
replace ZE

070645 199
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

302002 ZE 3: system error OS-TMS initialising error test total in EPROM/FLASH erroneous E 2
entry of error in error memory, all crane movements will be stopped
replace ZE

302006 ZE 3: system error OS-TMS initialising error RAM erroneous E 2


entry of error in error memory, all crane movements will be stopped
replace ZE

302007 ZE 3: system error OS-TMS UART erroneous E 2


entry of error in error memory, all crane movements will be stopped
replace ZE

302020 ZE 3: system error OS-TMS task-watchdog expired E 2


entry of error in error memory, all crane movements will be stopped
elimination only possible through after-sales service

302021 ZE 3: system error OS-TMS illegal opcode trap E 2


entry of error in error memory, all crane movements will be stopped
elimination only possible through after-sales service

302082 ZE 3: system error OS-TMS hardware-watchdog erroneous E 2


entry of error in error memory, all crane movements will be stopped
elimination only possible through after-sales service

310012 ZE 3: output 0 short circuit to ground X73:16 E 1

310013 ZE 3: output 0 open signal circuits X73:16 E 1

310014 ZE 3: output 0 short circuit to supply voltage X73:16 E 1

310054 ZE 3: output 0 short circuit to supply voltage X73:16 E 1

070645 200
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

310058 ZE 3: output 0 positive switching transistor: disruption X73:16 E 1

310060 ZE 3: output 0 safety chain error, diode defect or safety contact sticking X73:16 E 1
report of error, otherwise no reaction
checking of safety contact and diode

310070 ZE 3: output 0 measuring system defect X73:16 E 1


no crane operation possible entry in error list

310071 ZE 3: output 0 short circuit to ground or transistor defect X73:16 E 1

310072 ZE 3: output 0 outside source feeding X73:16 E 1

310073 ZE 3: output 0 open circuit or short circuit to supply voltage/ground X73:16 E 1

310112 ZE 3: output 1 short circuit to ground X73:17 E 1

310113 ZE 3: output 1 open signal circuits X73:17 E 1

310114 ZE 3: output 1 short circuit to supply voltage X73:17 E 1

310154 ZE 3: output 1 short circuit to supply voltage X73:17 E 1

070645 201
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

310158 ZE 3: output 1 positive switching transistor: disruption X73:17 E 1

310160 ZE 3: output 1 safety chain error, diode defect or safety contact sticking X73:17 E 1
report of error, otherwise no reaction
checking of safety contact and diode

310170 ZE 3: output 1 measuring system defect X73:17 E 1


no crane operation possible entry in error list

310171 ZE 3: output 1 short circuit to ground or transistor defect X73:17 E 1

310172 ZE 3: output 1 outside source feeding X73:17 E 1

310173 ZE 3: output 1 open circuit or short circuit to supply voltage/ground X73:17 E 1

310212 ZE 3: output 2 short circuit to ground X73:18 E 1

310213 ZE 3: output 2 open signal circuits X73:18 E 1

310214 ZE 3: output 2 short circuit to supply voltage X73:18 E 1

310254 ZE 3: output 2 short circuit to supply voltage X73:18 E 1

070645 202
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

310258 ZE 3: output 2 positive switching transistor: disruption X73:18 E 1

310270 ZE 3: output 2 measuring system defect X73:18 E 1


no crane operation possible entry in error list

310271 ZE 3: output 2 short circuit to ground or transistor defect X73:18 E 1

310272 ZE 3: output 2 outside source feeding X73:18 E 1

310273 ZE 3: output 2 open circuit or short circuit to supply voltage/ground X73:18 E 1

310312 ZE 3: output 3 short circuit to ground X73:19 E 1

310313 ZE 3: output 3 open signal circuits X73:19 E 1

310314 ZE 3: output 3 short circuit to supply voltage X73:19 E 1

310354 ZE 3: output 3 short circuit to supply voltage X73:19 E 1

310358 ZE 3: output 3 positive switching transistor: disruption X73:19 E 1

070645 203
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

310370 ZE 3: output 3 measuring system defect X73:19 E 1


no crane operation possible entry in error list

310371 ZE 3: output 3 short circuit to ground or transistor defect X73:19 E 1

310372 ZE 3: output 3 outside source feeding X73:19 E 1

310373 ZE 3: output 3 open circuit or short circuit to supply voltage/ground X73:19 E 1

310412 ZE 3: output 4 short circuit to ground X73:20 E 1

310413 ZE 3: output 4 open signal circuits X73:20 E 1

310414 ZE 3: output 4 short circuit to supply voltage X73:20 E 1

310454 ZE 3: output 4 short circuit to supply voltage X73:20 E 1

310458 ZE 3: output 4 positive switching transistor: disruption X73:20 E 1

310460 ZE 3: output 4 safety chain error, diode defect or safety contact sticking X73:20 E 1
report of error, otherwise no reaction
checking of safety contact and diode

070645 204
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

310470 ZE 3: output 4 measuring system defect X73:20 E 1


no crane operation possible entry in error list

310471 ZE 3: output 4 short circuit to ground or transistor defect X73:20 E 1

310472 ZE 3: output 4 outside source feeding X73:20 E 1

310473 ZE 3: output 4 open circuit or short circuit to supply voltage/ground X73:20 E 1

310512 ZE 3: output 5 short circuit to ground X73:21 E 1

310513 ZE 3: output 5 open signal circuits X73:21 E 1

310514 ZE 3: output 5 short circuit to supply voltage X73:21 E 1

310554 ZE 3: output 5 short circuit to supply voltage X73:21 E 1

310558 ZE 3: output 5 positive switching transistor: disruption X73:21 E 1

310560 ZE 3: output 5 safety chain error, diode defect or safety contact sticking X73:21 E 1
report of error, otherwise no reaction
checking of safety contact and diode

070645 205
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

310570 ZE 3: output 5 measuring system defect X73:21 E 1


no crane operation possible entry in error list

310571 ZE 3: output 5 short circuit to ground or transistor defect X73:21 E 1

310572 ZE 3: output 5 outside source feeding X73:21 E 1

310573 ZE 3: output 5 open circuit or short circuit to supply voltage/ground X73:21 E 1

310612 ZE 3: output 6 short circuit to ground X73:22 E 1

310613 ZE 3: output 6 open signal circuits X73:22 E 1

310614 ZE 3: output 6 short circuit to supply voltage X73:22 E 1

310654 ZE 3: output 6 short circuit to supply voltage X73:22 E 1

310658 ZE 3: output 6 positive switching transistor: disruption X73:22 E 1

310670 ZE 3: output 6 measuring system defect X73:22 E 1


no crane operation possible entry in error list

070645 206
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

310671 ZE 3: output 6 short circuit to ground or transistor defect X73:22 E 1

310672 ZE 3: output 6 outside source feeding X73:22 E 1

310673 ZE 3: output 6 open circuit or short circuit to supply voltage/ground X73:22 E 1

310712 ZE 3: output 7 short circuit to ground X73:23 E 1

310713 ZE 3: output 7 open signal circuits X73:23 E 1

310714 ZE 3: output 7 short circuit to supply voltage X73:23 E 1

310754 ZE 3: output 7 short circuit to supply voltage X73:23 E 1

310758 ZE 3: output 7 positive switching transistor: disruption X73:23 E 1

310760 ZE 3: output 7 safety chain error, diode defect or safety contact sticking X73:23 E 1
report of error, otherwise no reaction
checking of safety contact and diode

310770 ZE 3: output 7 measuring system defect X73:23 E 1


no crane operation possible entry in error list

070645 207
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

310771 ZE 3: output 7 short circuit to ground or transistor defect X73:23 E 1

310772 ZE 3: output 7 outside source feeding X73:23 E 1

310773 ZE 3: output 7 open circuit or short circuit to supply voltage/ground X73:23 E 1

314959 ZE 3: all output supply voltage missing X73 E 1

315059 ZE 3: output group 0 supply voltage missing X73:12 E 1

315159 ZE 3: output group 1 supply voltage missing X73:24 E 1

315259 ZE 3: output group 2 supply voltage missing X73:25 E 1

315359 ZE 3: output group 3 supply voltage missing X73:13 E 1

320004 ZE 3: LSB participant address 0 level exceeded X635C:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

320005 ZE 3: LSB participant address 0 below minimum level X635C:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

070645 208
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

320018 ZE 3: LSB participant address 0 excess temperature X635C:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

320050 ZE 3: LSB participant address 0 reports an incorrect sensor type X635C:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

320051 ZE 3: LSB participant address 0 was not configured for the block transfer X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

320053 ZE 3: LSB participant address 0 no longer reports or withdrawn during running period X635C:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

320054 ZE 3: LSB participant address 0 Features other settings (parameters) as pre-entered set values X635C:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

320064 ZE 3: LSB participant address 0 reports tolerable error in self-test X635C:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

320065 ZE 3: LSB participant address 0 reports intolerable error in self-test X635C:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

320066 ZE 3: LSB participant address 0 with software version, that is no longer compatible X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

320067 ZE 3: LSB participant address 0 supports no download function X635C:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

320104 ZE 3: LSB participant address 1 level exceeded X635C:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

070645 209
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

320105 ZE 3: LSB participant address 1 below minimum level X635C:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

320118 ZE 3: LSB participant address 1 excess temperature X635C:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

320150 ZE 3: LSB participant address 1 reports an incorrect sensor type X635C:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

320151 ZE 3: LSB participant address 1 was not configured for the block transfer X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

320153 ZE 3: LSB participant address 1 no longer reports or withdrawn during running period X635C:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

320154 ZE 3: LSB participant address 1 Features other settings (parameters) as pre-entered set values X635C:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

320164 ZE 3: LSB participant address 1 reports tolerable error in self-test X635C:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

320165 ZE 3: LSB participant address 1 reports intolerable error in self-test X635C:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

320166 ZE 3: LSB participant address 1 with software version, that is no longer compatible X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

320167 ZE 3: LSB participant address 1 supports no download function X635C:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

070645 210
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

320904 ZE 3: LSB participant address 9 level exceeded X635C:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

320905 ZE 3: LSB participant address 9 below minimum level X635C:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

320918 ZE 3: LSB participant address 9 excess temperature X635C:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

320950 ZE 3: LSB participant address 9 reports an incorrect sensor type X635C:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

320951 ZE 3: LSB participant address 9 was not configured for the block transfer X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

320953 ZE 3: LSB participant address 9 no longer reports or withdrawn during running period X635C:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

320954 ZE 3: LSB participant address 9 Features other settings (parameters) as pre-entered set values X635C:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

320964 ZE 3: LSB participant address 9 reports tolerable error in self-test X635C:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

320965 ZE 3: LSB participant address 9 reports intolerable error in self-test X635C:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

320966 ZE 3: LSB participant address 9 with software version, that is no longer compatible X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

070645 211
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

320967 ZE 3: LSB participant address 9 supports no download function X635C:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

321004 ZE 3: LSB participant address 10 level exceeded X635C:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

321005 ZE 3: LSB participant address 10 below minimum level X635C:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

321018 ZE 3: LSB participant address 10 excess temperature X635C:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

321050 ZE 3: LSB participant address 10 reports an incorrect sensor type X635C:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

321051 ZE 3: LSB participant address 10 was not configured for the block transfer X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

321053 ZE 3: LSB participant address 10 no longer reports or withdrawn during running period X635C:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

321054 ZE 3: LSB participant address 10 Features other settings (parameters) as pre-entered set values X635C:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

321064 ZE 3: LSB participant address 10 reports tolerable error in self-test X635C:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

321065 ZE 3: LSB participant address 10 reports intolerable error in self-test X635C:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

070645 212
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

321066 ZE 3: LSB participant address 10 with software version, that is no longer compatible X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

321067 ZE 3: LSB participant address 10 supports no download function X635C:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

321104 ZE 3: LSB participant address 11 level exceeded X635C:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

321105 ZE 3: LSB participant address 11 below minimum level X635C:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

321118 ZE 3: LSB participant address 11 excess temperature X635C:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

321150 ZE 3: LSB participant address 11 reports an incorrect sensor type X635C:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

321151 ZE 3: LSB participant address 11 was not configured for the block transfer X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

321153 ZE 3: LSB participant address 11 no longer reports or withdrawn during running period X635C:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

321154 ZE 3: LSB participant address 11 Features other settings (parameters) as pre-entered set values X635C:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

321164 ZE 3: LSB participant address 11 reports tolerable error in self-test X635C:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

070645 213
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

321165 ZE 3: LSB participant address 11 reports intolerable error in self-test X635C:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

321166 ZE 3: LSB participant address 11 with software version, that is no longer compatible X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

321167 ZE 3: LSB participant address 11 supports no download function X635C:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

321204 ZE 3: LSB participant address 12 level exceeded X635C:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

321205 ZE 3: LSB participant address 12 below minimum level X635C:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

321218 ZE 3: LSB participant address 12 excess temperature X635C:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

321250 ZE 3: LSB participant address 12 reports an incorrect sensor type X635C:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

321251 ZE 3: LSB participant address 12 was not configured for the block transfer X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

321253 ZE 3: LSB participant address 12 no longer reports or withdrawn during running period X635C:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

321254 ZE 3: LSB participant address 12 Features other settings (parameters) as pre-entered set values X635C:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

070645 214
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

321264 ZE 3: LSB participant address 12 reports tolerable error in self-test X635C:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

321265 ZE 3: LSB participant address 12 reports intolerable error in self-test X635C:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

321266 ZE 3: LSB participant address 12 with software version, that is no longer compatible X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

321267 ZE 3: LSB participant address 12 supports no download function X635C:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

321304 ZE 3: LSB participant address 13 level exceeded X635C:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

321305 ZE 3: LSB participant address 13 below minimum level X635C:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

321318 ZE 3: LSB participant address 13 excess temperature X635C:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

321350 ZE 3: LSB participant address 13 reports an incorrect sensor type X635C:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

321351 ZE 3: LSB participant address 13 was not configured for the block transfer X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

321353 ZE 3: LSB participant address 13 no longer reports or withdrawn during running period X635C:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

070645 215
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

321354 ZE 3: LSB participant address 13 Features other settings (parameters) as pre-entered set values X635C:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

321364 ZE 3: LSB participant address 13 reports tolerable error in self-test X635C:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

321365 ZE 3: LSB participant address 13 reports intolerable error in self-test X635C:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

321366 ZE 3: LSB participant address 13 with software version, that is no longer compatible X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

321367 ZE 3: LSB participant address 13 supports no download function X635C:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

321404 ZE 3: LSB participant address 14 level exceeded X635C:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

321405 ZE 3: LSB participant address 14 below minimum level X635C:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

321418 ZE 3: LSB participant address 14 excess temperature X635C:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

321450 ZE 3: LSB participant address 14 reports an incorrect sensor type X635C:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

321451 ZE 3: LSB participant address 14 was not configured for the block transfer X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

070645 216
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

321453 ZE 3: LSB participant address 14 no longer reports or withdrawn during running period X635C:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

321454 ZE 3: LSB participant address 14 Features other settings (parameters) as pre-entered set values X635C:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

321464 ZE 3: LSB participant address 14 reports tolerable error in self-test X635C:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

321465 ZE 3: LSB participant address 14 reports intolerable error in self-test X635C:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

321466 ZE 3: LSB participant address 14 with software version, that is no longer compatible X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

321467 ZE 3: LSB participant address 14 supports no download function X635C:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

321504 ZE 3: LSB participant address 15 level exceeded X635C:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

321505 ZE 3: LSB participant address 15 below minimum level X635C:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

321518 ZE 3: LSB participant address 15 excess temperature X635C:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

321550 ZE 3: LSB participant address 15 reports an incorrect sensor type X635C:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

070645 217
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

321551 ZE 3: LSB participant address 15 was not configured for the block transfer X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

321553 ZE 3: LSB participant address 15 no longer reports or withdrawn during running period X635C:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

321554 ZE 3: LSB participant address 15 Features other settings (parameters) as pre-entered set values X635C:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

321564 ZE 3: LSB participant address 15 reports tolerable error in self-test X635C:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

321565 ZE 3: LSB participant address 15 reports intolerable error in self-test X635C:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

321566 ZE 3: LSB participant address 15 with software version, that is no longer compatible X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

321567 ZE 3: LSB participant address 15 supports no download function X635C:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

321604 ZE 3: LSB participant address 16 level exceeded X635C:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

321605 ZE 3: LSB participant address 16 below minimum level X635C:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

321618 ZE 3: LSB participant address 16 excess temperature X635C:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

070645 218
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

321650 ZE 3: LSB participant address 16 reports an incorrect sensor type X635C:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

321651 ZE 3: LSB participant address 16 was not configured for the block transfer X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

321653 ZE 3: LSB participant address 16 no longer reports or withdrawn during running period X635C:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

321654 ZE 3: LSB participant address 16 Features other settings (parameters) as pre-entered set values X635C:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

321664 ZE 3: LSB participant address 16 reports tolerable error in self-test X635C:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

321665 ZE 3: LSB participant address 16 reports intolerable error in self-test X635C:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

321666 ZE 3: LSB participant address 16 with software version, that is no longer compatible X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

321667 ZE 3: LSB participant address 16 supports no download function X635C:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

322104 ZE 3: LSB participant address 21 level exceeded X635C:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

322105 ZE 3: LSB participant address 21 below minimum level X635C:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

070645 219
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

322118 ZE 3: LSB participant address 21 excess temperature X635C:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

322150 ZE 3: LSB participant address 21 reports an incorrect sensor type X635C:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

322151 ZE 3: LSB participant address 21 was not configured for the block transfer X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

322153 ZE 3: LSB participant address 21 no longer reports or withdrawn during running period X635C:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

322154 ZE 3: LSB participant address 21 Features other settings (parameters) as pre-entered set values X635C:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

322164 ZE 3: LSB participant address 21 reports tolerable error in self-test X635C:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

322165 ZE 3: LSB participant address 21 reports intolerable error in self-test X635C:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

322166 ZE 3: LSB participant address 21 with software version, that is no longer compatible X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

322167 ZE 3: LSB participant address 21 supports no download function X635C:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

322204 ZE 3: LSB participant address 22 level exceeded X635C:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

070645 220
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

322205 ZE 3: LSB participant address 22 below minimum level X635C:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

322218 ZE 3: LSB participant address 22 excess temperature X635C:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

322250 ZE 3: LSB participant address 22 reports an incorrect sensor type X635C:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

322251 ZE 3: LSB participant address 22 was not configured for the block transfer X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

322253 ZE 3: LSB participant address 22 no longer reports or withdrawn during running period X635C:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

322254 ZE 3: LSB participant address 22 Features other settings (parameters) as pre-entered set values X635C:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

322264 ZE 3: LSB participant address 22 reports tolerable error in self-test X635C:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

322265 ZE 3: LSB participant address 22 reports intolerable error in self-test X635C:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

322266 ZE 3: LSB participant address 22 with software version, that is no longer compatible X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

322267 ZE 3: LSB participant address 22 supports no download function X635C:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

070645 221
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

322804 ZE 3: LSB participant address 28 level exceeded X635C:z14/z16 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

322805 ZE 3: LSB participant address 28 below minimum level X635C:z14/z16 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

322818 ZE 3: LSB participant address 28 excess temperature X635C:z14/z16 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

322850 ZE 3: LSB participant address 28 reports an incorrect sensor type X635C:z14/z16 E 2


entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

322851 ZE 3: LSB participant address 28 was not configured for the block transfer X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

322853 ZE 3: LSB participant address 28 no longer reports or withdrawn during running period X635C:z14/z16 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

322854 ZE 3: LSB participant address 28 Features other settings (parameters) as pre-entered set values X635C:z14/z16 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

322864 ZE 3: LSB participant address 28 reports tolerable error in self-test X635C:z14/z16 E 1


entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

322865 ZE 3: LSB participant address 28 reports intolerable error in self-test X635C:z14/z16 E 2


entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

322866 ZE 3: LSB participant address 28 with software version, that is no longer compatible X635C:z14/z16 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

070645 222
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

322867 ZE 3: LSB participant address 28 supports no download function X635C:z14/z16 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

323252 ZE 3: Control data transfer LSB has recognised Bus collisions, communication interrupted X635C:z14/z16 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor

323255 ZE 3: Control data transfer LSB Bus connection faulty/defect, short circuit to supply voltage X635C:z14/z16 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

323256 ZE 3: Control data transfer LSB Bus connection faulty/defect, no supply/short circuit to earth X635C:z14/z16 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

323257 ZE 3: Control data transfer LSB has recognised network re-set (data transfer starts again) X635C:z14/z16 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part

323258 ZE 3: Control data transfer LSB recognised participant with incorrect baud rate in bus X635C:z14/z16 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors

323259 ZE 3: Control data transfer LSB recognised communication breakdown in bus X635C:z14/z16 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network

323260 ZE 3: Control data transfer LSB driver error: no order to carry out X635C:z14/z16 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software

323261 ZE 3: Control data transfer LSB driver error: undefined message appears X635C:z14/z16 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination

323262 ZE 3: Control data transfer LSB Driver error: Initialization error X635C:z14/z16 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination

070645 223
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

332100 ZE 3: control winch 2 no slewing movement recognized on actuated winch E 1


operational shut down
check LICCON output, lines for short or break, incremental sensor on function, hoisting gear brake

332102 ZE 3: control winch 2 hydraulic circuit pressure sensor defective/missing E 1


Output of error
check connection, if connection OK then replace sensor

333029 ZE 3: control auxiliary equipment Switch "Hose drum brake open" switched or short circuit E 1
Telescoping is shut off
Fix short circuit

335101 ZE 3: operation winch 2 feed pressure supply missing/too low B


Operation conditional switch off, may not be shunted
Reestablish charge pressure supply - shut-down may not be shunted

335104 ZE 3: operation winch 2 unreeled winch shut-down B


Operation conditional switch off, may not be shunted
reel in winch until the "winch reeled out" switch is no longer actuated - shut-down cannot be shunted

335105 ZE 3: operation winch 2 reeled winch shut-down B


Operation conditional switch off, may not be shunted
reel out winch until the "winch reeled in" switch is no longer actuated -shut-down cannot be shunted

335106 ZE 3: operation winch 2 upper angle limit OGW shut-down B


operational shut down
reel winch out until the radius is within the load chart again - shut-down can be shunted (danger)

335107 ZE 3: operation winch 2 lower angle limit UGW shut-down B


operational shut down
reel winch in until the radius is within the load chart again - shut-down can be shunted (danger)

335110 ZE 3: operation winch 2 fly jib upper stop shut-down B


Operation conditional switch off, may not be shunted
Luff down jib until limit switch no longer activated - shut-down may not be activated

335111 ZE 3: operation winch 2 fly jib upper flap shut-down B


Operation conditional switch off, may not be shunted
Luff down jib until limit switch no longer activated - shut-down may not be activated

070645 224
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

335112 ZE 3: operation winch 2 shut-down as lower fly jib and NA-boom 3 not positioned B
Operation conditional switch off, may not be shunted
reel winch in until limit switch is no longer actuated - shut-down cannot be shunted

335113 ZE 3: operation winch 2 shut-down as flap not positioned and angle threshold exceeded B
Operation conditional switch off, may not be shunted
check as to why the flap is not in position - shut-down cannot be shunted

335114 ZE 3: operation winch 2 pressure retaining cylinder RFP N shut-down outside set range B
Operation conditional switch off, may not be shunted
Wind off winch until pressure is once again within the desired range - shut-down may not be shunted .

335115 ZE 3: operation winch 2 adjustable pulley-N on stop shut-down B


Operation conditional switch off, may not be shunted
reel winch out till limit switch no longer actuated - shut-down can be shunted through switch unplugging (danger)

335116 ZE 3: operation winch 2 luffing up accessory shut-down working area limitation ABB B
operational shut down
reel winch out until crane in working area again - shunting through shutting down of working area limitation

335117 ZE 3: operation winch 2 luffing down accessory shut-down working area limitation ABB B
operational shut down
reel winch in until crane in working area again - shunting through shutting down of working area limitation

335119 ZE 3: operation winch 2 no or invalid operation mode shut-down B


Operation conditional switch off, may not be shunted
enter correct operation mode or dismantle accessory parts - shut-down cannot be shunted

335120 ZE 3: operation winch 2 LMB shut-down B


operational shut down
Remedy cause of "LMB Stop" see error report LMB - shut-down may be shunted via assembly switch (danger).

335123 ZE 3: operation winch 2 transport setting assembly unit-N shut-down B

335129 ZE 3: operation winch 2 winch blocked (C-key monitor) B


Operation conditional switch off, may not be shunted
Authorise winch 2 in control diagram.

070645 225
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

335130 ZE 3: operation winch 2 master switch 1 defective/missing B


operational shut down
Turn master switch to zero position. Otherwise note system error for defective or missing sensors.

335131 ZE 3: operation winch 2 master switch 2 defective/missing B


operational shut down
Turn master switch to zero position. Otherwise note system error for defective or missing sensors.

335139 ZE 3: operation winch 2 seat contact shut-down B


operational shut down
Sit down or actuate one of the shunting switches for the seat contact in the master switches.

335144 ZE 3: operation winch 2 Shut-off crane engine not running B

335149 ZE 3: operation winch 2 Shut-down hoist limit switch 4 B


operational shut down
control winch in opposite direction until end stroke switch no longer active - shut-down can be shunted (danger)

335150 ZE 3: operation winch 2 end of stroke switch shut-down 1 B


operational shut down
control winch in opposite direction until end stroke switch no longer active - shut-down can be shunted (danger)

335151 ZE 3: operation winch 2 end of stroke switch shut-down 2 B


operational shut down
control winch in opposite direction until end stroke switch no longer active - shut-down can be shunted (danger)

335152 ZE 3: operation winch 2 end of stroke switch shut-down 3 B


operational shut down
control winch in opposite direction until end stroke switch no longer active - shut-down can be shunted (danger)

335161 ZE 3: operation winch 2 Winch shut-down not mounted or incompletely / incorrectly mounted B
operational shut down
Release master switch - check pin on winch frame

335170 ZE 3: operation winch 2 shut-down both limit switches "flap in position" defect./missing B
Operation conditional switch off, may not be shunted
release master switch - error elimination see corresponding system error

070645 226
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

335171 ZE 3: operation winch 2 shut-down both limit switches "NA-boom 3 pos." defect./missing B
Operation conditional switch off, may not be shunted
release master switch - error elimination see corresponding system error

335172 ZE 3: operation winch 2 shut-down both angle sensors "fly jib" defective/missing B
Operation conditional switch off, may not be shunted
release master switch - error elimination see corresponding system error

335173 ZE 3: operation winch 2 shut-down both limit switches "lower fly jib" defective/missing B
Operation conditional switch off, may not be shunted
release master switch - error elimination see corresponding system error

335174 ZE 3: operation winch 2 shut-down both limit switches "upper fly jib flap" defect./missing B
Operation conditional switch off, may not be shunted
release master switch - error elimination see corresponding system error

335175 ZE 3: operation winch 2 shut-down both limit switches "upper fly jib stop"defect./missing B
Operation conditional switch off, may not be shunted
release master switch - error elimination see corresponding system error

335176 ZE 3: operation winch 2 shut-down limit switch adjustable pulley-N defective/missing B


Operation conditional switch off, may not be shunted
release master switch - error elimination see corresponding system error

335181 ZE 3: operation winch 2 end of stroke switch 1 shut-down defective B


operational shut down
Error remedying see corresponding system error - shut-down may be shunted (danger)

335182 ZE 3: operation winch 2 end of stroke switch 2 shut-down defective B


operational shut down
Error remedying see corresponding system error - shut-down may be shunted (danger)

335183 ZE 3: operation winch 2 end of stroke switch 3 shut-down defective B


operational shut down
Error remedying see corresponding system error - shut-down may be shunted (danger)

335184 ZE 3: operation winch 2 shut-down both limit switches "transp. setting N" defect./missing B

070645 227
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

335189 ZE 3: operation winch 2 Shut-down hoist limit switch 4 faulty B


operational shut down
Error remedying see corresponding system error - shut-down may be shunted (danger)

336018 ZE 3: operation additional equipment Shut-off incorrect operation type, incorrectly set up or not sold B 1

336029 ZE 3: operation additional equipment Button "Spool hose drum up / out" is stuck or actuated during start B 1
operational shut down
Release button or fix short circuit

336044 ZE 3: operation additional equipment Shut-off crane engine not running B

361001 E/A-Modul 3: system error OS-C167 initialising error processor-register erroneous E 2


error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

361002 E/A-Modul 3: system error OS-C167 initialising error test total in EPROM/FLASH erroneous E 2
error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

361006 E/A-Modul 3: system error OS-C167 initialising error RAM erroneous E 2


error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

361013 E/A-Modul 3: system error OS-C167 test total in EPROM/FLASH erroneous E 2


error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

361016 E/A-Modul 3: system error OS-C167 system-, driver-watchdog expired E 2


error indication on display
note error report, ignition ON/OFF, with repeated occurrence --> inform after-sales service

361068 E/A-Modul 3: system error OS-C167 impermissible interrupt E 2


error indication on display
note error report, ignition ON/OFF, with repeated occurrence --> inform after-sales service

070645 228
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

361071 E/A-Modul 3: system error OS-C167 Invalid configuration or Firmware E 2


error indication on display
re-load Software from ZE

361080 E/A-Modul 3: system error OS-C167 fatal internal software error E 2


error indication on display
note error report, ignition ON/OFF, with repeated occurrence --> inform after-sales service

361082 E/A-Modul 3: system error OS-C167 hardware-watchdog erroneous E 2


error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

361088 E/A-Modul 3: system error OS-C167 Configuration does not match software condition E 1
Error output, possible error functions of module
Carry out EAM-download from LICCON

361089 E/A-Modul 3: system error OS-C167 Incorrect version of firmware installed E 1


Error output, possible error functions of module
Replace module, reload firmware

361090 E/A-Modul 3: system error OS-C167 Incorrect hardware version recognised E 1


Error output, possible error functions of module
Replace module

372052 E/A-Modul 3: input/output DEA0 output open, to low load, short circuit to supply voltage X633:17 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

372053 E/A-Modul 3: input/output DEA0 transistor current supply insufficient or missing X633:17 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

372054 E/A-Modul 3: input/output DEA0 short circuit to supply voltage X633:17 E 1


error report on display
check output for short, if necessary replace E/A-Modul

372055 E/A-Modul 3: input/output DEA0 excessive temperature, short circuit to ground or overload X633:17 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

070645 229
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

372152 E/A-Modul 3: input/output DEA1 output open, to low load, short circuit to supply voltage X633:15 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

372153 E/A-Modul 3: input/output DEA1 transistor current supply insufficient or missing X633:15 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

372154 E/A-Modul 3: input/output DEA1 short circuit to supply voltage X633:15 E 1


error report on display
check output for short, if necessary replace E/A-Modul

372155 E/A-Modul 3: input/output DEA1 excessive temperature, short circuit to ground or overload X633:15 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

372252 E/A-Modul 3: input/output DEA2 output open, to low load, short circuit to supply voltage X633:13 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

372253 E/A-Modul 3: input/output DEA2 transistor current supply insufficient or missing X633:13 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

372254 E/A-Modul 3: input/output DEA2 short circuit to supply voltage X633:13 E 1


error report on display
check output for short, if necessary replace E/A-Modul

372255 E/A-Modul 3: input/output DEA2 excessive temperature, short circuit to ground or overload X633:13 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

372352 E/A-Modul 3: input/output DEA3 output open, to low load, short circuit to supply voltage X633:11 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

372353 E/A-Modul 3: input/output DEA3 transistor current supply insufficient or missing X633:11 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

070645 230
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

372354 E/A-Modul 3: input/output DEA3 short circuit to supply voltage X633:11 E 1


error report on display
check output for short, if necessary replace E/A-Modul

372355 E/A-Modul 3: input/output DEA3 excessive temperature, short circuit to ground or overload X633:11 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

372452 E/A-Modul 3: input/output DEA4 output open, to low load, short circuit to supply voltage X633:9 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

372453 E/A-Modul 3: input/output DEA4 transistor current supply insufficient or missing X633:9 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

372454 E/A-Modul 3: input/output DEA4 short circuit to supply voltage X633:9 E 1


error report on display
check output for short, if necessary replace E/A-Modul

372455 E/A-Modul 3: input/output DEA4 excessive temperature, short circuit to ground or overload X633:9 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

372552 E/A-Modul 3: input/output DEA5 output open, to low load, short circuit to supply voltage X633:7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

372553 E/A-Modul 3: input/output DEA5 transistor current supply insufficient or missing X633:7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

372554 E/A-Modul 3: input/output DEA5 short circuit to supply voltage X633:7 E 1


error report on display
check output for short, if necessary replace E/A-Modul

372555 E/A-Modul 3: input/output DEA5 excessive temperature, short circuit to ground or overload X633:7 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

070645 231
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

372652 E/A-Modul 3: input/output DEA6 output open, to low load, short circuit to supply voltage X633:5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

372653 E/A-Modul 3: input/output DEA6 transistor current supply insufficient or missing X633:5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

372654 E/A-Modul 3: input/output DEA6 short circuit to supply voltage X633:5 E 1


error report on display
check output for short, if necessary replace E/A-Modul

372655 E/A-Modul 3: input/output DEA6 excessive temperature, short circuit to ground or overload X633:5 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

372752 E/A-Modul 3: input/output DEA7 output open, to low load, short circuit to supply voltage X633:3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

372753 E/A-Modul 3: input/output DEA7 transistor current supply insufficient or missing X633:3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

372754 E/A-Modul 3: input/output DEA7 short circuit to supply voltage X633:3 E 1


error report on display
check output for short, if necessary replace E/A-Modul

372755 E/A-Modul 3: input/output DEA7 excessive temperature, short circuit to ground or overload X633:3 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

373017 E/A-Modul 3: current input E0 voltage below required value X632:17 E 1


on both support operating units "E." is flashing on the display for support force front right
check input signal on the E/A-Modul or sensor

373080 E/A-Modul 3: current input E0 short circuit to ground, open line, voltage sensor erroneous X632:17 E 1
on both support operating units "E." is flashing on the display for support force front right
check input signal on the E/A-Modul or sensor

070645 232
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

373117 E/A-Modul 3: current input E1 voltage below required value X632:15 E 1


on both support operating units "E." is flashing on the display for support force rear right
check input signal on the E/A-Modul or sensor

373180 E/A-Modul 3: current input E1 short circuit to ground, open line, voltage sensor erroneous X632:15 E 1
on both support operating units "E." is flashing on the display for support force rear right
check input signal on the E/A-Modul or sensor

373217 E/A-Modul 3: current input E2 voltage below required value X632:13 E 1


both outer LEDs for transversal inclination on both support operating units are flashing
check input signal on the E/A-Modul or sensor

373280 E/A-Modul 3: current input E2 short circuit to ground, open line, voltage sensor erroneous X632:13 E 1
both outer LEDs for transversal inclination on both support operating units are flashing
check input signal on the E/A-Modul or sensor

373317 E/A-Modul 3: current input E3 voltage below required value X632:11 E 1


both outer LEDs for longitudinal inclination are flashing on both support units
check input signal on the E/A-Modul or sensor

373380 E/A-Modul 3: current input E3 short circuit to ground, open line, voltage sensor erroneous X632:11 E 1
both outer LEDs for longitudinal inclination are flashing on both support units
check input signal on the E/A-Modul or sensor

373782 E/A-Modul 3: voltage input E7 short circuit to ground, open line, constant current 10 mA incorrect X632:3 E 1
symbol for diesel tank is flashing on the display unit, as are 3 question marks on monitor in uppercarriage
check input signal on the E/A-Modul or sensor

373783 E/A-Modul 3: voltage input E7 short circuit to supply voltage, open line, lack of voltage X632:3 E 1
symbol for diesel tank is flashing on the display unit, as are 3 question marks on monitor in uppercarriage
check input signal on the E/A-Modul or sensor

379052 E/A-Modul 3: output A0 output open, to low load, short circuit to supply voltage X633:18 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

379053 E/A-Modul 3: output A0 transistor current supply insufficient or missing X633:18 E 1


error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

070645 233
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

379054 E/A-Modul 3: output A0 short circuit to supply voltage X633:18 E 1


error report on display
check output for short, if necessary replace E/A-Modul

379055 E/A-Modul 3: output A0 excessive temperature, short circuit to ground or overload X633:18 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

379152 E/A-Modul 3: output A1 output open, to low load, short circuit to supply voltage X633:16 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

379153 E/A-Modul 3: output A1 transistor current supply insufficient or missing X633:16 E 1


error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

379154 E/A-Modul 3: output A1 short circuit to supply voltage X633:16 E 1


error report on display
check output for short, if necessary replace E/A-Modul

379155 E/A-Modul 3: output A1 excessive temperature, short circuit to ground or overload X633:16 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

379250 E/A-Modul 3: bridge output A2 short circuit to ground, junction not supplied X633:14 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul

379251 E/A-Modul 3: bridge output A2 short circuit to supply voltage, excessive temperature X633:14 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul

379252 E/A-Modul 3: bridge output A2 output open, to low load, short circuit to supply voltage X633:14 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

379253 E/A-Modul 3: bridge output A2 transistor current supply insufficient or missing X633:14 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

070645 234
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

379254 E/A-Modul 3: bridge output A2 short circuit to supply voltage X633:14 E 1


error report on display
check output for short, if necessary replace E/A-Modul

379255 E/A-Modul 3: bridge output A2 excessive temperature, short circuit to ground or overload X633:14 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

379350 E/A-Modul 3: bridge output A3 short circuit to ground, junction not supplied X633:12 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul

379351 E/A-Modul 3: bridge output A3 short circuit to supply voltage, excessive temperature X633:12 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul

379352 E/A-Modul 3: bridge output A3 output open, to low load, short circuit to supply voltage X633:12 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

379353 E/A-Modul 3: bridge output A3 transistor current supply insufficient or missing X633:12 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

379354 E/A-Modul 3: bridge output A3 short circuit to supply voltage X633:12 E 1


error report on display
check output for short, if necessary replace E/A-Modul

379355 E/A-Modul 3: bridge output A3 excessive temperature, short circuit to ground or overload X633:12 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

383501 E/A-Modul 3: SPI-support unit right Faulty data transfer E/A-module<>unit (time exceeded) X634:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul

383502 E/A-Modul 3: SPI-support unit right Serious system error to SPI-connection (interface) X634:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul

070645 235
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

383503 E/A-Modul 3: SPI-support unit right break in line or short circuit to supply voltage X634:1/2/3/5/6/ E 1
error indication on display 7/8
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary

383504 E/A-Modul 3: SPI-support unit right break in line or short circuit to ground X634:1/2/3/5/6/ E 1
error indication on display 7/8
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary

383506 E/A-Modul 3: SPI-support unit right Data transfer faulty (faulty check byte) X634:1/2/3/5/6/ E 1
error indication on display 7/8
suppress EMV- interference

383507 E/A-Modul 3: SPI-support unit right Unit faulty/missing, incorrect unit inserted (ID) X634:1/2/3/5/6/ E 1
error indication on display 7/8
check periphery and replace if necessary, check Software version, check EMV- interference

383508 E/A-Modul 3: SPI-support unit right Data transfer faulty (incorrect number of data bytes received) X634:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul

383900 E/A-Modul 3: Control operating unit (SPI) Faulty initialisation data connection E/A-module<>unit X634:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul

383902 E/A-Modul 3: Control operating unit (SPI) Serious system error to SPI-connection (interface) X634:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul

383905 E/A-Modul 3: Control operating unit (SPI) Initialisation error, resetting inputs/outputs faulty X634:1/2/3/5/6/ E 1
error indication on display 7/8
check wiring, check periphery and replace if necessary, check E/A-Modul and replace if necessary

383907 E/A-Modul 3: Control operating unit (SPI) Unit faulty/missing, incorrect unit inserted (ID) X634:1/2/3/5/6/ E 1
error indication on display 7/8
connect functional periphery unit, system then eliminates error independently

383908 E/A-Modul 3: Control operating unit (SPI) Data transfer faulty (incorrect number of data bytes received) X634:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul

070645 236
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

384104 E/A-Modul 3: LSB-B participant address 1 level exceeded X633:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

384105 E/A-Modul 3: LSB-B participant address 1 below minimum level X633:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

384118 E/A-Modul 3: LSB-B participant address 1 excess temperature X633:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

384150 E/A-Modul 3: LSB-B participant address 1 reports an incorrect sensor type X633:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

384151 E/A-Modul 3: LSB-B participant address 1 was not configured for the block transfer X633:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

384153 E/A-Modul 3: LSB-B participant address 1 no longer reports or withdrawn during running period X633:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

384154 E/A-Modul 3: LSB-B participant address 1 Features other settings (parameters) as pre-entered set values X633:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

384164 E/A-Modul 3: LSB-B participant address 1 reports tolerable error in self-test X633:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

384165 E/A-Modul 3: LSB-B participant address 1 reports intolerable error in self-test X633:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

384166 E/A-Modul 3: LSB-B participant address 1 with software version, that is no longer compatible X633:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

070645 237
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

384167 E/A-Modul 3: LSB-B participant address 1 supports no download function X633:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

384204 E/A-Modul 3: LSB-B participant address 2 level exceeded X633:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

384205 E/A-Modul 3: LSB-B participant address 2 below minimum level X633:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

384218 E/A-Modul 3: LSB-B participant address 2 excess temperature X633:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

384250 E/A-Modul 3: LSB-B participant address 2 reports an incorrect sensor type X633:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

384251 E/A-Modul 3: LSB-B participant address 2 was not configured for the block transfer X633:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

384253 E/A-Modul 3: LSB-B participant address 2 no longer reports or withdrawn during running period X633:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

384254 E/A-Modul 3: LSB-B participant address 2 Features other settings (parameters) as pre-entered set values X633:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

384264 E/A-Modul 3: LSB-B participant address 2 reports tolerable error in self-test X633:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

384265 E/A-Modul 3: LSB-B participant address 2 reports intolerable error in self-test X633:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

070645 238
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

384266 E/A-Modul 3: LSB-B participant address 2 with software version, that is no longer compatible X633:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

384267 E/A-Modul 3: LSB-B participant address 2 supports no download function X633:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

384304 E/A-Modul 3: LSB-B participant address 3 level exceeded X633:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

384305 E/A-Modul 3: LSB-B participant address 3 below minimum level X633:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

384318 E/A-Modul 3: LSB-B participant address 3 excess temperature X633:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

384350 E/A-Modul 3: LSB-B participant address 3 reports an incorrect sensor type X633:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

384351 E/A-Modul 3: LSB-B participant address 3 was not configured for the block transfer X633:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

384353 E/A-Modul 3: LSB-B participant address 3 no longer reports or withdrawn during running period X633:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

384354 E/A-Modul 3: LSB-B participant address 3 Features other settings (parameters) as pre-entered set values X633:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

384364 E/A-Modul 3: LSB-B participant address 3 reports tolerable error in self-test X633:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

070645 239
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

384365 E/A-Modul 3: LSB-B participant address 3 reports intolerable error in self-test X633:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

384366 E/A-Modul 3: LSB-B participant address 3 with software version, that is no longer compatible X633:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

384367 E/A-Modul 3: LSB-B participant address 3 supports no download function X633:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

384404 E/A-Modul 3: LSB-B participant address 4 level exceeded X633:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

384405 E/A-Modul 3: LSB-B participant address 4 below minimum level X633:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

384418 E/A-Modul 3: LSB-B participant address 4 excess temperature X633:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

384450 E/A-Modul 3: LSB-B participant address 4 reports an incorrect sensor type X633:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

384451 E/A-Modul 3: LSB-B participant address 4 was not configured for the block transfer X633:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

384453 E/A-Modul 3: LSB-B participant address 4 no longer reports or withdrawn during running period X633:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

384454 E/A-Modul 3: LSB-B participant address 4 Features other settings (parameters) as pre-entered set values X633:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

070645 240
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

384464 E/A-Modul 3: LSB-B participant address 4 reports tolerable error in self-test X633:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

384465 E/A-Modul 3: LSB-B participant address 4 reports intolerable error in self-test X633:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

384466 E/A-Modul 3: LSB-B participant address 4 with software version, that is no longer compatible X633:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

384467 E/A-Modul 3: LSB-B participant address 4 supports no download function X633:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

384504 E/A-Modul 3: LSB-B participant address 5 level exceeded X633:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

384505 E/A-Modul 3: LSB-B participant address 5 below minimum level X633:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

384518 E/A-Modul 3: LSB-B participant address 5 excess temperature X633:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

384550 E/A-Modul 3: LSB-B participant address 5 reports an incorrect sensor type X633:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

384551 E/A-Modul 3: LSB-B participant address 5 was not configured for the block transfer X633:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

384553 E/A-Modul 3: LSB-B participant address 5 no longer reports or withdrawn during running period X633:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

070645 241
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

384554 E/A-Modul 3: LSB-B participant address 5 Features other settings (parameters) as pre-entered set values X633:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

384564 E/A-Modul 3: LSB-B participant address 5 reports tolerable error in self-test X633:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

384565 E/A-Modul 3: LSB-B participant address 5 reports intolerable error in self-test X633:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

384566 E/A-Modul 3: LSB-B participant address 5 with software version, that is no longer compatible X633:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

384567 E/A-Modul 3: LSB-B participant address 5 supports no download function X633:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

384604 E/A-Modul 3: LSB-B participant address 6 level exceeded X633:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

384605 E/A-Modul 3: LSB-B participant address 6 below minimum level X633:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

384618 E/A-Modul 3: LSB-B participant address 6 excess temperature X633:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

384650 E/A-Modul 3: LSB-B participant address 6 reports an incorrect sensor type X633:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

384651 E/A-Modul 3: LSB-B participant address 6 was not configured for the block transfer X633:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

070645 242
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

384653 E/A-Modul 3: LSB-B participant address 6 no longer reports or withdrawn during running period X633:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

384654 E/A-Modul 3: LSB-B participant address 6 Features other settings (parameters) as pre-entered set values X633:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

384664 E/A-Modul 3: LSB-B participant address 6 reports tolerable error in self-test X633:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

384665 E/A-Modul 3: LSB-B participant address 6 reports intolerable error in self-test X633:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

384666 E/A-Modul 3: LSB-B participant address 6 with software version, that is no longer compatible X633:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

384667 E/A-Modul 3: LSB-B participant address 6 supports no download function X633:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

387252 E/A-Modul 3: Control data transfer LSB-B has recognised Bus collisions, communication interrupted X633:4/6 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor

387255 E/A-Modul 3: Control data transfer LSB-B Bus connection faulty/defect, short circuit to supply voltage X633:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

387256 E/A-Modul 3: Control data transfer LSB-B Bus connection faulty/defect, no supply/short circuit to earth X633:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

387257 E/A-Modul 3: Control data transfer LSB-B has recognised network re-set (data transfer starts again) X633:4/6 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part

070645 243
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

387258 E/A-Modul 3: Control data transfer LSB-B recognised participant with incorrect baud rate in bus X633:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors

387259 E/A-Modul 3: Control data transfer LSB-B recognised communication breakdown in bus X633:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network

387260 E/A-Modul 3: Control data transfer LSB-B driver error: no order to carry out X633:4/6 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software

387261 E/A-Modul 3: Control data transfer LSB-B driver error: undefined message appears X633:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination

387262 E/A-Modul 3: Control data transfer LSB-B Driver error: Initialization error X633:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination

392510 E/A-Modul 3: control axle suspension/level signals from transfer contact "axle elevated" simultaneous IN E 1
raise axles 3+4 function defective, function can be carried out with defective feedback
change-contact pressure switch >120 bar, Check cabling to short against supply voltage

392511 E/A-Modul 3: control axle suspension/level signals from transfer contact "axle elevated" simultaneous OUT E 1
raise axles 3+4 function defective, function can be carried out with defective feedback
change-contact pressure switch >120 bar, check cabling for wire break, fuse Kl.15

392830 E/A-Modul 3: control supports location coding for right support unit erroneous (set value = 0) E 2
support functions are blocked
check line connection to E/A-Modul, check ground connection from signal, replace E/A-Modul

392832 E/A-Modul 3: control supports right support unit key sticking or activated after switching on E 1
right support blocked
check/unplug/replace support operating unit release activated key

394190 E/A-Modul 3: LSB-bus participant ZE missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

070645 244
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

394191 E/A-Modul 3: LSB-bus participant E/A-Modul 1 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

394192 E/A-Modul 3: LSB-bus participant E/A-Modul 2 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

394194 E/A-Modul 3: LSB-bus participant E/A-Modul 4 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

394195 E/A-Modul 3: LSB-bus participant E/A-Modul 5 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

396408 E/A-Modul 3: operation supports unauthorised operation from upper-carriage B


function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

396409 E/A-Modul 3: operation supports unauthorised operation from under-carriage B


function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

396440 E/A-Modul 3: operation supports simultaneous UP and DOWN operation of support control unit B
function is not carried out
actuate UP key or DOWN key of the respective support operating unit, start test program support service unit

396441 E/A-Modul 3: operation supports simultaneous IN and OUT operation of support control unit B
function is not carried out
actuate OFF key or ON key of the respective support operating unit, start test program support operating unit

396442 E/A-Modul 3: operation supports simultaneous UP and DOWN operation on upper-carriage monitor B
function is not carried out
actuate UP key or DOWN key of the respective support operating unit, start test program support service unit

396443 E/A-Modul 3: operation supports simultaneous IN and OUT operation on upper-carriage monitor B
function is not carried out
actuate OFF key or ON key of the respective support operating unit, start test program support operating unit

070645 245
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

396444 E/A-Modul 3: operation supports simultaneous left and right operation of support control unit B
function is not carried out
actuate support from only one operating position, start test program support operating unit

396445 E/A-Modul 3: operation supports simultaneous operation of support control unit and upper-carriage B
function is not carried out
actuate support from only one operating position, start test program support operating unit

396446 E/A-Modul 3: operation supports simultaneous operation of support control unit and upper-carriage B
function is not carried out
actuate support from only one operating position, start test program support operating unit

396447 E/A-Modul 3: operation supports operation of support control unit with travel direction D engaged B
function is not carried out
switch transmission to neutral (N)

396448 E/A-Modul 3: operation supports operation of support control unit with travel direction R engaged B
function is not carried out
switch transmission to neutral (N)

396449 E/A-Modul 3: operation supports op. of upper-carriage monitor with travel direction D engaged B
function is not carried out
switch transmission to neutral (N)

396450 E/A-Modul 3: operation supports operation of upper-carriage-monitor R B


function is not carried out
switch transmission to neutral (N)

399890 E/A-Modul 3: operation diagnosis system test program not executable as engine is not OFF B
function is not carried out
shut down engine

399892 E/A-Modul 3: operation diagnosis system test program not executable as not in under-carriage op. mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode

402001 ZE 4: system error OS-TMS initialising error processor-register erroneous E 2


entry of error in error memory, all crane movements will be stopped
replace ZE

070645 246
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

402002 ZE 4: system error OS-TMS initialising error test total in EPROM/FLASH erroneous E 2
entry of error in error memory, all crane movements will be stopped
replace ZE

402006 ZE 4: system error OS-TMS initialising error RAM erroneous E 2


entry of error in error memory, all crane movements will be stopped
replace ZE

402007 ZE 4: system error OS-TMS UART erroneous E 2


entry of error in error memory, all crane movements will be stopped
replace ZE

402020 ZE 4: system error OS-TMS task-watchdog expired E 2


entry of error in error memory, all crane movements will be stopped
elimination only possible through after-sales service

402021 ZE 4: system error OS-TMS illegal opcode trap E 2


entry of error in error memory, all crane movements will be stopped
elimination only possible through after-sales service

402082 ZE 4: system error OS-TMS hardware-watchdog erroneous E 2


entry of error in error memory, all crane movements will be stopped
elimination only possible through after-sales service

461001 E/A-Modul 4: system error OS-C167 initialising error processor-register erroneous E 2


error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

461002 E/A-Modul 4: system error OS-C167 initialising error test total in EPROM/FLASH erroneous E 2
error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

461006 E/A-Modul 4: system error OS-C167 initialising error RAM erroneous E 2


error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

461013 E/A-Modul 4: system error OS-C167 test total in EPROM/FLASH erroneous E 2


error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

070645 247
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

461016 E/A-Modul 4: system error OS-C167 system-, driver-watchdog expired E 2


error indication on display
note error report, ignition ON/OFF, with repeated occurrence --> inform after-sales service

461068 E/A-Modul 4: system error OS-C167 impermissible interrupt E 2


error indication on display
note error report, ignition ON/OFF, with repeated occurrence --> inform after-sales service

461071 E/A-Modul 4: system error OS-C167 Invalid configuration or Firmware E 2


error indication on display
re-load Software from ZE

461080 E/A-Modul 4: system error OS-C167 fatal internal software error E 2


error indication on display
note error report, ignition ON/OFF, with repeated occurrence --> inform after-sales service

461082 E/A-Modul 4: system error OS-C167 hardware-watchdog erroneous E 2


error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

461088 E/A-Modul 4: system error OS-C167 Configuration does not match software condition E 1
Error output, possible error functions of module
Carry out EAM-download from LICCON

461089 E/A-Modul 4: system error OS-C167 Incorrect version of firmware installed E 1


Error output, possible error functions of module
Replace module, reload firmware

461090 E/A-Modul 4: system error OS-C167 Incorrect hardware version recognised E 1


Error output, possible error functions of module
Replace module

472052 E/A-Modul 4: input/output DEA0 output open, to low load, short circuit to supply voltage X643:17 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

472053 E/A-Modul 4: input/output DEA0 transistor current supply insufficient or missing X643:17 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

070645 248
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

472054 E/A-Modul 4: input/output DEA0 short circuit to supply voltage X643:17 E 1


error report on display
check output for short, if necessary replace E/A-Modul

472055 E/A-Modul 4: input/output DEA0 excessive temperature, short circuit to ground or overload X643:17 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

472152 E/A-Modul 4: input/output DEA1 output open, to low load, short circuit to supply voltage X643:15 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

472153 E/A-Modul 4: input/output DEA1 transistor current supply insufficient or missing X643:15 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

472154 E/A-Modul 4: input/output DEA1 short circuit to supply voltage X643:15 E 1


error report on display
check output for short, if necessary replace E/A-Modul

472155 E/A-Modul 4: input/output DEA1 excessive temperature, short circuit to ground or overload X643:15 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

472252 E/A-Modul 4: input/output DEA2 output open, to low load, short circuit to supply voltage X643:13 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

472253 E/A-Modul 4: input/output DEA2 transistor current supply insufficient or missing X643:13 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

472254 E/A-Modul 4: input/output DEA2 short circuit to supply voltage X643:13 E 1


error report on display
check output for short, if necessary replace E/A-Modul

472255 E/A-Modul 4: input/output DEA2 excessive temperature, short circuit to ground or overload X643:13 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

070645 249
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

472352 E/A-Modul 4: input/output DEA3 output open, to low load, short circuit to supply voltage X643:11 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

472353 E/A-Modul 4: input/output DEA3 transistor current supply insufficient or missing X643:11 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

472354 E/A-Modul 4: input/output DEA3 short circuit to supply voltage X643:11 E 1


error report on display
check output for short, if necessary replace E/A-Modul

472355 E/A-Modul 4: input/output DEA3 excessive temperature, short circuit to ground or overload X643:11 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

472452 E/A-Modul 4: input/output DEA4 output open, to low load, short circuit to supply voltage X643:9 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

472453 E/A-Modul 4: input/output DEA4 transistor current supply insufficient or missing X643:9 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

472454 E/A-Modul 4: input/output DEA4 short circuit to supply voltage X643:9 E 1


error report on display
check output for short, if necessary replace E/A-Modul

472455 E/A-Modul 4: input/output DEA4 excessive temperature, short circuit to ground or overload X643:9 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

472552 E/A-Modul 4: input/output DEA5 output open, to low load, short circuit to supply voltage X643:7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

472553 E/A-Modul 4: input/output DEA5 transistor current supply insufficient or missing X643:7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

070645 250
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

472554 E/A-Modul 4: input/output DEA5 short circuit to supply voltage X643:7 E 1


error report on display
check output for short, if necessary replace E/A-Modul

472555 E/A-Modul 4: input/output DEA5 excessive temperature, short circuit to ground or overload X643:7 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

472652 E/A-Modul 4: input/output DEA6 output open, to low load, short circuit to supply voltage X643:5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

472653 E/A-Modul 4: input/output DEA6 transistor current supply insufficient or missing X643:5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

472654 E/A-Modul 4: input/output DEA6 short circuit to supply voltage X643:5 E 1


error report on display
check output for short, if necessary replace E/A-Modul

472655 E/A-Modul 4: input/output DEA6 excessive temperature, short circuit to ground or overload X643:5 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

472752 E/A-Modul 4: input/output DEA7 output open, to low load, short circuit to supply voltage X643:3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

472753 E/A-Modul 4: input/output DEA7 transistor current supply insufficient or missing X643:3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

472754 E/A-Modul 4: input/output DEA7 short circuit to supply voltage X643:3 E 1


error report on display
check output for short, if necessary replace E/A-Modul

472755 E/A-Modul 4: input/output DEA7 excessive temperature, short circuit to ground or overload X643:3 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

070645 251
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

473017 E/A-Modul 4: current input E0 voltage below required value X642:17 E 1


on both support operating units "E." is flashing on the display for support force front left
check input signal on the E/A-Modul or sensor

473080 E/A-Modul 4: current input E0 short circuit to ground, open line, voltage sensor erroneous X642:17 E 1
on both support operating units "E." is flashing on the display for support force front left
check input signal on the E/A-Modul or sensor

473117 E/A-Modul 4: current input E1 voltage below required value X642:15 E 1


on both support operating units "E." is flashing on the display for support force rear left
check input signal on the E/A-Modul or sensor

473180 E/A-Modul 4: current input E1 short circuit to ground, open line, voltage sensor erroneous X642:15 E 1
on both support operating units "E." is flashing on the display for support force rear left
check input signal on the E/A-Modul or sensor

479052 E/A-Modul 4: output A0 output open, to low load, short circuit to supply voltage X643:18 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

479053 E/A-Modul 4: output A0 transistor current supply insufficient or missing X643:18 E 1


error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

479054 E/A-Modul 4: output A0 short circuit to supply voltage X643:18 E 1


error report on display
check output for short, if necessary replace E/A-Modul

479055 E/A-Modul 4: output A0 excessive temperature, short circuit to ground or overload X643:18 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

479152 E/A-Modul 4: output A1 output open, to low load, short circuit to supply voltage X643:16 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

479153 E/A-Modul 4: output A1 transistor current supply insufficient or missing X643:16 E 1


error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

070645 252
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

479154 E/A-Modul 4: output A1 short circuit to supply voltage X643:16 E 1


error report on display
check output for short, if necessary replace E/A-Modul

479155 E/A-Modul 4: output A1 excessive temperature, short circuit to ground or overload X643:16 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

479250 E/A-Modul 4: bridge output A2 short circuit to ground, junction not supplied X643:14 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul

479251 E/A-Modul 4: bridge output A2 short circuit to supply voltage, excessive temperature X643:14 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul

479252 E/A-Modul 4: bridge output A2 output open, to low load, short circuit to supply voltage X643:14 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

479253 E/A-Modul 4: bridge output A2 transistor current supply insufficient or missing X643:14 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

479254 E/A-Modul 4: bridge output A2 short circuit to supply voltage X643:14 E 1


error report on display
check output for short, if necessary replace E/A-Modul

479255 E/A-Modul 4: bridge output A2 excessive temperature, short circuit to ground or overload X643:14 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

479350 E/A-Modul 4: bridge output A3 short circuit to ground, junction not supplied X643:12 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul

479351 E/A-Modul 4: bridge output A3 short circuit to supply voltage, excessive temperature X643:12 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul

070645 253
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

479352 E/A-Modul 4: bridge output A3 output open, to low load, short circuit to supply voltage X643:12 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

479353 E/A-Modul 4: bridge output A3 transistor current supply insufficient or missing X643:12 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

479354 E/A-Modul 4: bridge output A3 short circuit to supply voltage X643:12 E 1


error report on display
check output for short, if necessary replace E/A-Modul

479355 E/A-Modul 4: bridge output A3 excessive temperature, short circuit to ground or overload X643:12 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

483601 E/A-Modul 4: SPI-support unit left Faulty data transfer E/A-module<>unit (time exceeded) X644:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul

483602 E/A-Modul 4: SPI-support unit left Serious system error to SPI-connection (interface) X644:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul

483603 E/A-Modul 4: SPI-support unit left break in line or short circuit to supply voltage X644:1/2/3/5/6/ E 1
error indication on display 7/8
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary

483604 E/A-Modul 4: SPI-support unit left break in line or short circuit to ground X644:1/2/3/5/6/ E 1
error indication on display 7/8
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary

483606 E/A-Modul 4: SPI-support unit left Data transfer faulty (faulty check byte) X644:1/2/3/5/6/ E 1
error indication on display 7/8
suppress EMV- interference

483607 E/A-Modul 4: SPI-support unit left Unit faulty/missing, incorrect unit inserted (ID) X644:1/2/3/5/6/ E 1
error indication on display 7/8
check periphery and replace if necessary, check Software version, check EMV- interference

070645 254
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

483608 E/A-Modul 4: SPI-support unit left Data transfer faulty (incorrect number of data bytes received) X644:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul

483900 E/A-Modul 4: Control operating unit (SPI) Faulty initialisation data connection E/A-module<>unit X644:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul

483902 E/A-Modul 4: Control operating unit (SPI) Serious system error to SPI-connection (interface) X644:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul

483905 E/A-Modul 4: Control operating unit (SPI) Initialisation error, resetting inputs/outputs faulty X644:1/2/3/5/6/ E 1
error indication on display 7/8
check wiring, check periphery and replace if necessary, check E/A-Modul and replace if necessary

483907 E/A-Modul 4: Control operating unit (SPI) Unit faulty/missing, incorrect unit inserted (ID) X644:1/2/3/5/6/ E 1
error indication on display 7/8
connect functional periphery unit, system then eliminates error independently

483908 E/A-Modul 4: Control operating unit (SPI) Data transfer faulty (incorrect number of data bytes received) X644:1/2/3/5/6/ E 1
error indication on display 7/8
system re-starts SPI-driver and eliminates error independently, with repeated occurrence replace E/A-Modul

484104 E/A-Modul 4: LSB-B participant address 1 level exceeded X643:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

484105 E/A-Modul 4: LSB-B participant address 1 below minimum level X643:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

484118 E/A-Modul 4: LSB-B participant address 1 excess temperature X643:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

484150 E/A-Modul 4: LSB-B participant address 1 reports an incorrect sensor type X643:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

070645 255
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

484151 E/A-Modul 4: LSB-B participant address 1 was not configured for the block transfer X643:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

484153 E/A-Modul 4: LSB-B participant address 1 no longer reports or withdrawn during running period X643:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

484154 E/A-Modul 4: LSB-B participant address 1 Features other settings (parameters) as pre-entered set values X643:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

484164 E/A-Modul 4: LSB-B participant address 1 reports tolerable error in self-test X643:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

484165 E/A-Modul 4: LSB-B participant address 1 reports intolerable error in self-test X643:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

484166 E/A-Modul 4: LSB-B participant address 1 with software version, that is no longer compatible X643:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

484167 E/A-Modul 4: LSB-B participant address 1 supports no download function X643:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

484204 E/A-Modul 4: LSB-B participant address 2 level exceeded X643:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

484205 E/A-Modul 4: LSB-B participant address 2 below minimum level X643:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

484218 E/A-Modul 4: LSB-B participant address 2 excess temperature X643:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

070645 256
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

484250 E/A-Modul 4: LSB-B participant address 2 reports an incorrect sensor type X643:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

484251 E/A-Modul 4: LSB-B participant address 2 was not configured for the block transfer X643:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

484253 E/A-Modul 4: LSB-B participant address 2 no longer reports or withdrawn during running period X643:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

484254 E/A-Modul 4: LSB-B participant address 2 Features other settings (parameters) as pre-entered set values X643:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

484264 E/A-Modul 4: LSB-B participant address 2 reports tolerable error in self-test X643:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

484265 E/A-Modul 4: LSB-B participant address 2 reports intolerable error in self-test X643:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

484266 E/A-Modul 4: LSB-B participant address 2 with software version, that is no longer compatible X643:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

484267 E/A-Modul 4: LSB-B participant address 2 supports no download function X643:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

484304 E/A-Modul 4: LSB-B participant address 3 level exceeded X643:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

484305 E/A-Modul 4: LSB-B participant address 3 below minimum level X643:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

070645 257
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

484318 E/A-Modul 4: LSB-B participant address 3 excess temperature X643:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

484350 E/A-Modul 4: LSB-B participant address 3 reports an incorrect sensor type X643:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

484351 E/A-Modul 4: LSB-B participant address 3 was not configured for the block transfer X643:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

484353 E/A-Modul 4: LSB-B participant address 3 no longer reports or withdrawn during running period X643:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

484354 E/A-Modul 4: LSB-B participant address 3 Features other settings (parameters) as pre-entered set values X643:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

484364 E/A-Modul 4: LSB-B participant address 3 reports tolerable error in self-test X643:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

484365 E/A-Modul 4: LSB-B participant address 3 reports intolerable error in self-test X643:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

484366 E/A-Modul 4: LSB-B participant address 3 with software version, that is no longer compatible X643:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

484367 E/A-Modul 4: LSB-B participant address 3 supports no download function X643:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

484404 E/A-Modul 4: LSB-B participant address 4 level exceeded X643:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

070645 258
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

484405 E/A-Modul 4: LSB-B participant address 4 below minimum level X643:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

484418 E/A-Modul 4: LSB-B participant address 4 excess temperature X643:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

484450 E/A-Modul 4: LSB-B participant address 4 reports an incorrect sensor type X643:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

484451 E/A-Modul 4: LSB-B participant address 4 was not configured for the block transfer X643:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

484453 E/A-Modul 4: LSB-B participant address 4 no longer reports or withdrawn during running period X643:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

484454 E/A-Modul 4: LSB-B participant address 4 Features other settings (parameters) as pre-entered set values X643:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

484464 E/A-Modul 4: LSB-B participant address 4 reports tolerable error in self-test X643:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

484465 E/A-Modul 4: LSB-B participant address 4 reports intolerable error in self-test X643:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

484466 E/A-Modul 4: LSB-B participant address 4 with software version, that is no longer compatible X643:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

484467 E/A-Modul 4: LSB-B participant address 4 supports no download function X643:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

070645 259
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

484504 E/A-Modul 4: LSB-B participant address 5 level exceeded X643:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

484505 E/A-Modul 4: LSB-B participant address 5 below minimum level X643:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

484518 E/A-Modul 4: LSB-B participant address 5 excess temperature X643:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

484550 E/A-Modul 4: LSB-B participant address 5 reports an incorrect sensor type X643:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

484551 E/A-Modul 4: LSB-B participant address 5 was not configured for the block transfer X643:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

484553 E/A-Modul 4: LSB-B participant address 5 no longer reports or withdrawn during running period X643:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

484554 E/A-Modul 4: LSB-B participant address 5 Features other settings (parameters) as pre-entered set values X643:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

484564 E/A-Modul 4: LSB-B participant address 5 reports tolerable error in self-test X643:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

484565 E/A-Modul 4: LSB-B participant address 5 reports intolerable error in self-test X643:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

484566 E/A-Modul 4: LSB-B participant address 5 with software version, that is no longer compatible X643:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

070645 260
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

484567 E/A-Modul 4: LSB-B participant address 5 supports no download function X643:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

484604 E/A-Modul 4: LSB-B participant address 6 level exceeded X643:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

484605 E/A-Modul 4: LSB-B participant address 6 below minimum level X643:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

484618 E/A-Modul 4: LSB-B participant address 6 excess temperature X643:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

484650 E/A-Modul 4: LSB-B participant address 6 reports an incorrect sensor type X643:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

484651 E/A-Modul 4: LSB-B participant address 6 was not configured for the block transfer X643:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

484653 E/A-Modul 4: LSB-B participant address 6 no longer reports or withdrawn during running period X643:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

484654 E/A-Modul 4: LSB-B participant address 6 Features other settings (parameters) as pre-entered set values X643:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

484664 E/A-Modul 4: LSB-B participant address 6 reports tolerable error in self-test X643:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

484665 E/A-Modul 4: LSB-B participant address 6 reports intolerable error in self-test X643:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

070645 261
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

484666 E/A-Modul 4: LSB-B participant address 6 with software version, that is no longer compatible X643:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

484667 E/A-Modul 4: LSB-B participant address 6 supports no download function X643:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

487252 E/A-Modul 4: Control data transfer LSB-B has recognised Bus collisions, communication interrupted X643:4/6 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor

487255 E/A-Modul 4: Control data transfer LSB-B Bus connection faulty/defect, short circuit to supply voltage X643:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

487256 E/A-Modul 4: Control data transfer LSB-B Bus connection faulty/defect, no supply/short circuit to earth X643:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

487257 E/A-Modul 4: Control data transfer LSB-B has recognised network re-set (data transfer starts again) X643:4/6 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part

487258 E/A-Modul 4: Control data transfer LSB-B recognised participant with incorrect baud rate in bus X643:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors

487259 E/A-Modul 4: Control data transfer LSB-B recognised communication breakdown in bus X643:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network

487260 E/A-Modul 4: Control data transfer LSB-B driver error: no order to carry out X643:4/6 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software

487261 E/A-Modul 4: Control data transfer LSB-B driver error: undefined message appears X643:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination

070645 262
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

487262 E/A-Modul 4: Control data transfer LSB-B Driver error: Initialization error X643:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination

492747 E/A-Modul 4: control steering signal from steering pump flow switch erroneous E 1
control indicator for steering pump flashing
check line connections, power supply 10 mA from E/A-Modul; replace sensor or E/A-Modul

492748 E/A-Modul 4: control steering signal from auxiliary steering pump flow switch erroneous E 1
control indicator for auxiliary steering pump flashing
check line connections, power supply 10 mA from E/A-Modul; replace sensor or E/A-Modul

492831 E/A-Modul 4: control supports location coding for left support unit erroneous (set value = 1) E 2
support functions are blocked
check line connection to E/A-Modul, check power supply from signal, replace E/A-Modul

492833 E/A-Modul 4: control supports left support unit key sticking or activated after switching on E 1
left support blocked
check/unplug/replace support operating unit release activated key

494190 E/A-Modul 4: LSB-bus participant ZE missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

494191 E/A-Modul 4: LSB-bus participant E/A-Modul 1 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

494192 E/A-Modul 4: LSB-bus participant E/A-Modul 2 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

494193 E/A-Modul 4: LSB-bus participant E/A-Modul 3 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

494195 E/A-Modul 4: LSB-bus participant E/A-Modul 5 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

070645 263
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

496000 E/A-Modul 4: operation transversal lock function simultaneously ON and OFF B


function is not carried out
do not simultaneously activate contrasting function keys

496011 E/A-Modul 4: operation transversal lock unauthorised switching on of function B


function is not carried out
start engine and repeat operation

496012 E/A-Modul 4: operation transversal lock unauthorised switching off of function B


function is not carried out
start engine and repeat operation

496013 E/A-Modul 4: operation transversal lock unauthorised function activation B


function is not carried out
start engine and repeat operation

496014 E/A-Modul 4: operation transversal lock activation of function without operation mode B
function is not carried out
start engine and repeat operation

496100 E/A-Modul 4: operation unlocking rear axle function simultaneously ON and OFF B
function is not carried out
do not simultaneously activate contrasting function keys

496111 E/A-Modul 4: operation unlocking rear axle unauthorised switching on of function B


function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

496112 E/A-Modul 4: operation unlocking rear axle unauthorised switching off of function B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

496113 E/A-Modul 4: operation unlocking rear axle unauthorised function activation B


function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

496114 E/A-Modul 4: operation unlocking rear axle activation of function without operation mode B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

070645 264
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

496160 E/A-Modul 4: operation unlocking rear axle undefined condition: simultaneously locked and unlocked B
function is not carried out
check unlocking condition, Check locking limit switch and unlocking limit switch

496200 E/A-Modul 4: operation steering rear axle function simultaneously ON and OFF B
function is not carried out
do not simultaneously activate contrasting function keys

496213 E/A-Modul 4: operation steering rear axle unauthorised function activation B


function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

496214 E/A-Modul 4: operation steering rear axle activation of function without operation mode B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

496408 E/A-Modul 4: operation supports unauthorised operation from upper-carriage B


function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

496409 E/A-Modul 4: operation supports unauthorised operation from under-carriage B


function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

496440 E/A-Modul 4: operation supports simultaneous UP and DOWN operation of support control unit B
function is not carried out
actuate UP key or DOWN key of the respective support operating unit, start test program support service unit

496441 E/A-Modul 4: operation supports simultaneous IN and OUT operation of support control unit B
function is not carried out
actuate OFF key or ON key of the respective support operating unit, start test program support operating unit

496442 E/A-Modul 4: operation supports simultaneous UP and DOWN operation on upper-carriage monitor B
function is not carried out
actuate UP key or DOWN key of the respective support operating unit, start test program support service unit

496443 E/A-Modul 4: operation supports simultaneous IN and OUT operation on upper-carriage monitor B
function is not carried out
actuate OFF key or ON key of the respective support operating unit, start test program support operating unit

070645 265
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

496444 E/A-Modul 4: operation supports simultaneous left and right operation of support control unit B
function is not carried out
activate support from only one operating position or start test program support operating unit

496445 E/A-Modul 4: operation supports simultaneous operation of support control unit and upper-carriage B
function is not carried out
activate support from only one operating position or start test program support operating unit

496446 E/A-Modul 4: operation supports simultaneous operation of support control unit and upper-carriage B
function is not carried out
activate support from only one operating position or start test program support operating unit

496447 E/A-Modul 4: operation supports operation of support control unit with travel direction D engaged B
function is not carried out
switch transmission to neutral (N)

496448 E/A-Modul 4: operation supports operation of support control unit with travel direction R engaged B
function is not carried out
switch transmission to neutral (N)

496449 E/A-Modul 4: operation supports op. of upper-carriage monitor with travel direction D engaged B
function is not carried out
switch transmission to neutral (N)

496450 E/A-Modul 4: operation supports operation of upper-carriage-monitor R B


function is not carried out
switch transmission to neutral (N)

499890 E/A-Modul 4: operation diagnosis system test program not executable as engine is not OFF B
function is not carried out
shut down engine

499892 E/A-Modul 4: operation diagnosis system test program not executable as not in under-carriage op. mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode

502001 ZE 5: system error OS-TMS initialising error processor-register erroneous E 2


entry of error in error memory, all crane movements will be stopped
replace ZE

070645 266
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

502002 ZE 5: system error OS-TMS initialising error test total in EPROM/FLASH erroneous E 2
entry of error in error memory, all crane movements will be stopped
replace ZE

502006 ZE 5: system error OS-TMS initialising error RAM erroneous E 2


entry of error in error memory, all crane movements will be stopped
replace ZE

502007 ZE 5: system error OS-TMS UART erroneous E 2


entry of error in error memory, all crane movements will be stopped
replace ZE

502020 ZE 5: system error OS-TMS task-watchdog expired E 2


entry of error in error memory, all crane movements will be stopped
elimination only possible through after-sales service

502021 ZE 5: system error OS-TMS illegal opcode trap E 2


entry of error in error memory, all crane movements will be stopped
elimination only possible through after-sales service

502082 ZE 5: system error OS-TMS hardware-watchdog erroneous E 2


entry of error in error memory, all crane movements will be stopped
elimination only possible through after-sales service

561001 E/A-Modul 5: system error OS-C167 initialising error processor-register erroneous E 2


error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

561002 E/A-Modul 5: system error OS-C167 initialising error test total in EPROM/FLASH erroneous E 2
error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

561006 E/A-Modul 5: system error OS-C167 initialising error RAM erroneous E 2


error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

561013 E/A-Modul 5: system error OS-C167 test total in EPROM/FLASH erroneous E 2


error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

070645 267
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

561016 E/A-Modul 5: system error OS-C167 system-, driver-watchdog expired E 2


error indication on display
note error report, ignition ON/OFF, with repeated occurrence --> inform after-sales service

561068 E/A-Modul 5: system error OS-C167 impermissible interrupt E 2


error indication on display
note error report, ignition ON/OFF, with repeated occurrence --> inform after-sales service

561071 E/A-Modul 5: system error OS-C167 Invalid configuration or Firmware E 2


error indication on display
re-load Software from ZE

561080 E/A-Modul 5: system error OS-C167 fatal internal software error E 2


error indication on display
note error report, ignition ON/OFF, with repeated occurrence --> inform after-sales service

561082 E/A-Modul 5: system error OS-C167 hardware-watchdog erroneous E 2


error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

561088 E/A-Modul 5: system error OS-C167 Configuration does not match software condition E 1
Error output, possible error functions of module
Carry out EAM-download from LICCON

561089 E/A-Modul 5: system error OS-C167 Incorrect version of firmware installed E 1


Error output, possible error functions of module
Replace module, reload firmware

561090 E/A-Modul 5: system error OS-C167 Incorrect hardware version recognised E 1


Error output, possible error functions of module
Replace module

572052 E/A-Modul 5: input/output DEA0 output open, to low load, short circuit to supply voltage X653:17 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

572053 E/A-Modul 5: input/output DEA0 transistor current supply insufficient or missing X653:17 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

070645 268
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

572054 E/A-Modul 5: input/output DEA0 short circuit to supply voltage X653:17 E 1


error report on display
check output for short, if necessary replace E/A-Modul

572055 E/A-Modul 5: input/output DEA0 excessive temperature, short circuit to ground or overload X653:17 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

572152 E/A-Modul 5: input/output DEA1 output open, to low load, short circuit to supply voltage X653:15 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

572153 E/A-Modul 5: input/output DEA1 transistor current supply insufficient or missing X653:15 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

572154 E/A-Modul 5: input/output DEA1 short circuit to supply voltage X653:15 E 1


error report on display
check output for short, if necessary replace E/A-Modul

572155 E/A-Modul 5: input/output DEA1 excessive temperature, short circuit to ground or overload X653:15 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

572252 E/A-Modul 5: input/output DEA2 output open, to low load, short circuit to supply voltage X653:13 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

572253 E/A-Modul 5: input/output DEA2 transistor current supply insufficient or missing X653:13 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

572254 E/A-Modul 5: input/output DEA2 short circuit to supply voltage X653:13 E 1


error report on display
check output for short, if necessary replace E/A-Modul

572255 E/A-Modul 5: input/output DEA2 excessive temperature, short circuit to ground or overload X653:13 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

070645 269
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

572352 E/A-Modul 5: input/output DEA3 output open, to low load, short circuit to supply voltage X653:11 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

572353 E/A-Modul 5: input/output DEA3 transistor current supply insufficient or missing X653:11 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

572354 E/A-Modul 5: input/output DEA3 short circuit to supply voltage X653:11 E 1


error report on display
check output for short, if necessary replace E/A-Modul

572355 E/A-Modul 5: input/output DEA3 excessive temperature, short circuit to ground or overload X653:11 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

572452 E/A-Modul 5: input/output DEA4 output open, to low load, short circuit to supply voltage X653:9 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

572453 E/A-Modul 5: input/output DEA4 transistor current supply insufficient or missing X653:9 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

572454 E/A-Modul 5: input/output DEA4 short circuit to supply voltage X653:9 E 1


error report on display
check output for short, if necessary replace E/A-Modul

572455 E/A-Modul 5: input/output DEA4 excessive temperature, short circuit to ground or overload X653:9 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

572552 E/A-Modul 5: input/output DEA5 output open, to low load, short circuit to supply voltage X653:7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

572553 E/A-Modul 5: input/output DEA5 transistor current supply insufficient or missing X653:7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

070645 270
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

572554 E/A-Modul 5: input/output DEA5 short circuit to supply voltage X653:7 E 1


error report on display
check output for short, if necessary replace E/A-Modul

572555 E/A-Modul 5: input/output DEA5 excessive temperature, short circuit to ground or overload X653:7 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

572652 E/A-Modul 5: input/output DEA6 output open, to low load, short circuit to supply voltage X653:5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

572653 E/A-Modul 5: input/output DEA6 transistor current supply insufficient or missing X653:5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

572654 E/A-Modul 5: input/output DEA6 short circuit to supply voltage X653:5 E 1


error report on display
check output for short, if necessary replace E/A-Modul

572655 E/A-Modul 5: input/output DEA6 excessive temperature, short circuit to ground or overload X653:5 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

572752 E/A-Modul 5: input/output DEA7 output open, to low load, short circuit to supply voltage X653:3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

572753 E/A-Modul 5: input/output DEA7 transistor current supply insufficient or missing X653:3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

572754 E/A-Modul 5: input/output DEA7 short circuit to supply voltage X653:3 E 1


error report on display
check output for short, if necessary replace E/A-Modul

572755 E/A-Modul 5: input/output DEA7 excessive temperature, short circuit to ground or overload X653:3 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

070645 271
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

573482 E/A-Modul 5: voltage input E4 short circuit to ground, open line, constant current 10 mA incorrect X652:9 E 1
gear oil temperature warning light flashing on the display unit
check input signal on the E/A-Modul or sensor

573483 E/A-Modul 5: voltage input E4 short circuit to supply voltage, open line, lack of voltage X652:9 E 1
gear oil temperature warning light flashing on the display unit
check input signal on the E/A-Modul or sensor

579052 E/A-Modul 5: output A0 output open, to low load, short circuit to supply voltage X653:18 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

579053 E/A-Modul 5: output A0 transistor current supply insufficient or missing X653:18 E 1


error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

579054 E/A-Modul 5: output A0 short circuit to supply voltage X653:18 E 1


error report on display
check output for short, if necessary replace E/A-Modul

579055 E/A-Modul 5: output A0 excessive temperature, short circuit to ground or overload X653:18 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

579152 E/A-Modul 5: output A1 output open, to low load, short circuit to supply voltage X653:16 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

579153 E/A-Modul 5: output A1 transistor current supply insufficient or missing X653:16 E 1


error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

579154 E/A-Modul 5: output A1 short circuit to supply voltage X653:16 E 1


error report on display
check output for short, if necessary replace E/A-Modul

579155 E/A-Modul 5: output A1 excessive temperature, short circuit to ground or overload X653:16 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

070645 272
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

579250 E/A-Modul 5: bridge output A2 short circuit to ground, junction not supplied X653:14 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul

579251 E/A-Modul 5: bridge output A2 short circuit to supply voltage, excessive temperature X653:14 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul

579252 E/A-Modul 5: bridge output A2 output open, to low load, short circuit to supply voltage X653:14 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

579253 E/A-Modul 5: bridge output A2 transistor current supply insufficient or missing X653:14 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

579254 E/A-Modul 5: bridge output A2 short circuit to supply voltage X653:14 E 1


error report on display
check output for short, if necessary replace E/A-Modul

579255 E/A-Modul 5: bridge output A2 excessive temperature, short circuit to ground or overload X653:14 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

579350 E/A-Modul 5: bridge output A3 short circuit to ground, junction not supplied X653:12 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul

579351 E/A-Modul 5: bridge output A3 short circuit to supply voltage, excessive temperature X653:12 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul

579352 E/A-Modul 5: bridge output A3 output open, to low load, short circuit to supply voltage X653:12 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

579353 E/A-Modul 5: bridge output A3 transistor current supply insufficient or missing X653:12 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

070645 273
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

579354 E/A-Modul 5: bridge output A3 short circuit to supply voltage X653:12 E 1


error report on display
check output for short, if necessary replace E/A-Modul

579355 E/A-Modul 5: bridge output A3 excessive temperature, short circuit to ground or overload X653:12 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

584104 E/A-Modul 5: LSB-B participant address 1 level exceeded X653:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

584105 E/A-Modul 5: LSB-B participant address 1 below minimum level X653:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

584118 E/A-Modul 5: LSB-B participant address 1 excess temperature X653:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

584150 E/A-Modul 5: LSB-B participant address 1 reports an incorrect sensor type X653:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

584151 E/A-Modul 5: LSB-B participant address 1 was not configured for the block transfer X653:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

584153 E/A-Modul 5: LSB-B participant address 1 no longer reports or withdrawn during running period X653:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

584154 E/A-Modul 5: LSB-B participant address 1 Features other settings (parameters) as pre-entered set values X653:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

584164 E/A-Modul 5: LSB-B participant address 1 reports tolerable error in self-test X653:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

070645 274
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

584165 E/A-Modul 5: LSB-B participant address 1 reports intolerable error in self-test X653:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

584166 E/A-Modul 5: LSB-B participant address 1 with software version, that is no longer compatible X653:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

584167 E/A-Modul 5: LSB-B participant address 1 supports no download function X653:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

584204 E/A-Modul 5: LSB-B participant address 2 level exceeded X653:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

584205 E/A-Modul 5: LSB-B participant address 2 below minimum level X653:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

584218 E/A-Modul 5: LSB-B participant address 2 excess temperature X653:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

584250 E/A-Modul 5: LSB-B participant address 2 reports an incorrect sensor type X653:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

584251 E/A-Modul 5: LSB-B participant address 2 was not configured for the block transfer X653:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

584253 E/A-Modul 5: LSB-B participant address 2 no longer reports or withdrawn during running period X653:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

584254 E/A-Modul 5: LSB-B participant address 2 Features other settings (parameters) as pre-entered set values X653:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

070645 275
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

584264 E/A-Modul 5: LSB-B participant address 2 reports tolerable error in self-test X653:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

584265 E/A-Modul 5: LSB-B participant address 2 reports intolerable error in self-test X653:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

584266 E/A-Modul 5: LSB-B participant address 2 with software version, that is no longer compatible X653:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

584267 E/A-Modul 5: LSB-B participant address 2 supports no download function X653:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

584304 E/A-Modul 5: LSB-B participant address 3 level exceeded X653:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

584305 E/A-Modul 5: LSB-B participant address 3 below minimum level X653:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

584318 E/A-Modul 5: LSB-B participant address 3 excess temperature X653:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

584350 E/A-Modul 5: LSB-B participant address 3 reports an incorrect sensor type X653:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

584351 E/A-Modul 5: LSB-B participant address 3 was not configured for the block transfer X653:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

584353 E/A-Modul 5: LSB-B participant address 3 no longer reports or withdrawn during running period X653:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

070645 276
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

584354 E/A-Modul 5: LSB-B participant address 3 Features other settings (parameters) as pre-entered set values X653:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

584364 E/A-Modul 5: LSB-B participant address 3 reports tolerable error in self-test X653:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

584365 E/A-Modul 5: LSB-B participant address 3 reports intolerable error in self-test X653:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

584366 E/A-Modul 5: LSB-B participant address 3 with software version, that is no longer compatible X653:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

584367 E/A-Modul 5: LSB-B participant address 3 supports no download function X653:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

584404 E/A-Modul 5: LSB-B participant address 4 level exceeded X653:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

584405 E/A-Modul 5: LSB-B participant address 4 below minimum level X653:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

584418 E/A-Modul 5: LSB-B participant address 4 excess temperature X653:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

584450 E/A-Modul 5: LSB-B participant address 4 reports an incorrect sensor type X653:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

584451 E/A-Modul 5: LSB-B participant address 4 was not configured for the block transfer X653:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

070645 277
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

584453 E/A-Modul 5: LSB-B participant address 4 no longer reports or withdrawn during running period X653:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

584454 E/A-Modul 5: LSB-B participant address 4 Features other settings (parameters) as pre-entered set values X653:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

584464 E/A-Modul 5: LSB-B participant address 4 reports tolerable error in self-test X653:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

584465 E/A-Modul 5: LSB-B participant address 4 reports intolerable error in self-test X653:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

584466 E/A-Modul 5: LSB-B participant address 4 with software version, that is no longer compatible X653:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

584467 E/A-Modul 5: LSB-B participant address 4 supports no download function X653:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

584504 E/A-Modul 5: LSB-B participant address 5 level exceeded X653:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

584505 E/A-Modul 5: LSB-B participant address 5 below minimum level X653:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

584518 E/A-Modul 5: LSB-B participant address 5 excess temperature X653:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

584550 E/A-Modul 5: LSB-B participant address 5 reports an incorrect sensor type X653:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

070645 278
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

584551 E/A-Modul 5: LSB-B participant address 5 was not configured for the block transfer X653:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

584553 E/A-Modul 5: LSB-B participant address 5 no longer reports or withdrawn during running period X653:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

584554 E/A-Modul 5: LSB-B participant address 5 Features other settings (parameters) as pre-entered set values X653:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

584564 E/A-Modul 5: LSB-B participant address 5 reports tolerable error in self-test X653:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

584565 E/A-Modul 5: LSB-B participant address 5 reports intolerable error in self-test X653:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

584566 E/A-Modul 5: LSB-B participant address 5 with software version, that is no longer compatible X653:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

584567 E/A-Modul 5: LSB-B participant address 5 supports no download function X653:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

584604 E/A-Modul 5: LSB-B participant address 6 level exceeded X653:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

584605 E/A-Modul 5: LSB-B participant address 6 below minimum level X653:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

584618 E/A-Modul 5: LSB-B participant address 6 excess temperature X653:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

070645 279
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

584650 E/A-Modul 5: LSB-B participant address 6 reports an incorrect sensor type X653:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

584651 E/A-Modul 5: LSB-B participant address 6 was not configured for the block transfer X653:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

584653 E/A-Modul 5: LSB-B participant address 6 no longer reports or withdrawn during running period X653:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

584654 E/A-Modul 5: LSB-B participant address 6 Features other settings (parameters) as pre-entered set values X653:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

584664 E/A-Modul 5: LSB-B participant address 6 reports tolerable error in self-test X653:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

584665 E/A-Modul 5: LSB-B participant address 6 reports intolerable error in self-test X653:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

584666 E/A-Modul 5: LSB-B participant address 6 with software version, that is no longer compatible X653:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

584667 E/A-Modul 5: LSB-B participant address 6 supports no download function X653:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

587252 E/A-Modul 5: Control data transfer LSB-B has recognised Bus collisions, communication interrupted X653:4/6 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor

587255 E/A-Modul 5: Control data transfer LSB-B Bus connection faulty/defect, short circuit to supply voltage X653:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

070645 280
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

587256 E/A-Modul 5: Control data transfer LSB-B Bus connection faulty/defect, no supply/short circuit to earth X653:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

587257 E/A-Modul 5: Control data transfer LSB-B has recognised network re-set (data transfer starts again) X653:4/6 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part

587258 E/A-Modul 5: Control data transfer LSB-B recognised participant with incorrect baud rate in bus X653:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors

587259 E/A-Modul 5: Control data transfer LSB-B recognised communication breakdown in bus X653:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network

587260 E/A-Modul 5: Control data transfer LSB-B driver error: no order to carry out X653:4/6 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software

587261 E/A-Modul 5: Control data transfer LSB-B driver error: undefined message appears X653:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination

587262 E/A-Modul 5: Control data transfer LSB-B Driver error: Initialization error X653:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination

587530 E/A-Modul 5: CAN-participant engine Data transfer subscriber transfer cycle exceeded X655:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant

587531 E/A-Modul 5: CAN-participant engine Data transfer faulty/missing, max. cycle time exceeded X655:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

587630 E/A-Modul 5: CAN-participant gear Data transfer subscriber transfer cycle exceeded X655:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul

070645 281
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

587631 E/A-Modul 5: CAN-participant gear Data transfer faulty/missing, max. cycle time exceeded X655:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

587730 E/A-Modul 5: CAN-participant ABV (ABS/ASR) Data transfer subscriber transfer cycle exceeded X655:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul

587731 E/A-Modul 5: CAN-participant ABV (ABS/ASR) Data transfer faulty/missing, max. cycle time exceeded X655:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

587930 E/A-Modul 5: CAN-participant retarder Data transfer subscriber transfer cycle exceeded X655:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul

587931 E/A-Modul 5: CAN-participant retarder Data transfer faulty/missing, max. cycle time exceeded X655:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

588030 E/A-Modul 5: CAN-user converter clutch unit CCU Data transfer subscriber transfer cycle exceeded X655:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul

588031 E/A-Modul 5: CAN-user converter clutch unit CCU Data transfer faulty/missing, max. cycle time exceeded X655:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

588530 E/A-Modul 5: CAN-participant E/A-Modul 1 Data transfer subscriber transfer cycle exceeded X655:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant

588531 E/A-Modul 5: CAN-participant E/A-Modul 1 Data transfer faulty/missing, max. cycle time exceeded X655:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

588930 E/A-Modul 5: CAN-participant E/A-Modul 5 Data transfer subscriber transfer cycle exceeded X655:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant

070645 282
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

588931 E/A-Modul 5: CAN-participant E/A-Modul 5 Data transfer faulty/missing, max. cycle time exceeded X655:5/6 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

589900 E/A-Modul 5: Control data transfer CAN internal error at Register-check Controller X655:5/6 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul

589901 E/A-Modul 5: Control data transfer CAN internal error at RAM-check Controller X655:5/6 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul

589902 E/A-Modul 5: Control data transfer CAN Configuration error Software X655:5/6 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul, check Software (test system ZE)

589903 E/A-Modul 5: Control data transfer CAN Transfer interrupted after continuous error X655:5/6 E 1
CAN-Transmission will be aborted
check bus lines/neutral point, replace neutral point or E/A-Modul

589910 E/A-Modul 5: Control data transfer CAN short-term error in bus connection X655:5/6 E 0
re-attachment of Modul to bus transmission
check bus lines/neutral point, unplug individual bus participant and check if error has been eliminated

589911 E/A-Modul 5: Control data transfer CAN permanent error bus connection X655:5/6 E 1
cyclic re-attachment of Modul to bus transmission
check bus lines/neutral point, unplug individual bus participant and check if error has been eliminated

589920 E/A-Modul 5: Control data transfer CAN active participant not responding X655:5/6 E 0
parameterised substitute values for receiver signals will be used
check error report for missing participant(s), test system ZE

589921 E/A-Modul 5: Control data transfer CAN No active subscriber responding X655:5/6 E 1
parameterised substitute values for receiver signals will be used
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul

589950 E/A-Modul 5: Control data transfer CAN erroneous command test system X655:5/6 E 1
no reaction to unknown test system control command in CAN-System Software
check Software (test system)

070645 283
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

592001 E/A-Modul 5: control engine long-term disruption E/A-Modul <-> engine control E 1
engine control and E/A-Modul at emergency speed
engine control and E/A-Modul, check CAN-bus-connections

592005 E/A-Modul 5: control engine condition erroneous: CAN-signal engine ON <-> load ctrl. D+ OFF E 1
identification engine ON/OFF possibly erronous
check alternator line connection to display unit, check alternator signal

592006 E/A-Modul 5: control engine condition erroneous: CAN-signal engine OFF <-> load ctrl. D+ ON E 1
identification engine ON/OFF possibly erronous
check alternator line connection to display unit, check alternator signal

592034 E/A-Modul 5: control engine Travel speed Tachograph missing E 1


Tempomat/Temposet-function blocked, engine will be limited in the torque output
Tacograph connection <>E/A-Modul, check signals to inputs from E/A-Modul; replace E/A-Modul Taco

592035 E/A-Modul 5: control engine Travel speed Tachograph incorrect E 1


Tempomat/Temposet-function blocked, engine will be limited in the torque output
Tacograph connection <>E/A-Modul, check signals to inputs from E/A-Modul; replace E/A-Modul Taco

592036 E/A-Modul 5: control engine Travel speed Tachograph <> Gear output RPM not plausible E 1
Tempomat/Temposet-function blocked, engine will be limited in the torque output
Tacograph connection <>E/A-Modul, signals to inputs from E/A-Modul, check gear speed; replace E/A-Modul Taco

592102 E/A-Modul 5: control transmission permanent malfunction E/A-Modul 1 <-> E/A-Modul 5 E 1


travel switch signals will be switched off, emergency operation
check CAN-bus system, E/A-Module 1 and 5

592121 E/A-Modul 5: control transmission shift selector-specified gear range/travel direction erroneous E 1
travel switch signals will be switched off, emergency operation
check CAN-bus system, Check Software in E/A-Modules (test system)

592123 E/A-Modul 5: control transmission switch prevention ("do not shift"), retrieve gear error E 1
transmission control shift-selector primary controls neutral or prevents the selection of a travel direction D/R
check transmission, E/A-Modul 5, lines

592124 E/A-Modul 5: control transmission control device reports error ("check trans"), retrieve gear error E 1
error report will be reported through control device if diagnosis key is permanently actuated
activate diagnosis key permanently until system error transmission appears

070645 284
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

592957 E/A-Modul 5: control brakes/pneumatic system brake pressure switch 0.5 bar signal "op. brakes active" missing E 1
operation brake signal activated if circle 1+2 > 1,5 bar, stronger application of the brake necessary
check connection from brake pressure switch to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593160 E/A-Modul 5: instruments operators cab auxiliary brakes signal level 1 missing E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593161 E/A-Modul 5: instruments operators cab auxiliary brakes signal level 2 missing E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593162 E/A-Modul 5: instruments operators cab auxiliary brakes signal level 3 missing E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593165 E/A-Modul 5: instruments operators cab auxiliary brakes signal level 1 short to supply voltage E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593166 E/A-Modul 5: instruments operators cab auxiliary brakes signal level 2 short to supply voltage E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593167 E/A-Modul 5: instruments operators cab auxiliary brakes signal level 3 short to supply voltage E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593175 E/A-Modul 5: instruments operators cab Tempomat lever no signal or supply voltage missing E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593176 E/A-Modul 5: instruments operators cab Tempomat lever signal SET+ no signal or short to ground E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593177 E/A-Modul 5: instruments operators cab Tempomat lever signal SET- no signal or short to ground E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

070645 285
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

593178 E/A-Modul 5: instruments operators cab Tempomat lever signal OFF no signal or short to ground E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593179 E/A-Modul 5: instruments operators cab Tempomat lever signal QUIT short to supply voltage E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593180 E/A-Modul 5: instruments operators cab Tempomat lever signal TEMPOSET short to supply voltage E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593181 E/A-Modul 5: instruments operators cab Tempomat lever signal TEMPOMAT SET+ without returning (QUIT) E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593182 E/A-Modul 5: instruments operators cab Tempomat lever signal TEMPOMAT SET- without returning (QUIT) E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593183 E/A-Modul 5: instruments operators cab Tempomat lever signal OFF without returning (QUIT) E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593184 E/A-Modul 5: instruments operators cab Tempomat lever signals SET+, SET-, OFF erroneous combination E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

594190 E/A-Modul 5: LSB-bus participant ZE missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

594191 E/A-Modul 5: LSB-bus participant E/A-Modul 1 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

594192 E/A-Modul 5: LSB-bus participant E/A-Modul 2 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

070645 286
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

594193 E/A-Modul 5: LSB-bus participant E/A-Modul 3 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

594194 E/A-Modul 5: LSB-bus participant E/A-Modul 4 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

595074 E/A-Modul 5: operation engine accelerator operators cab blocked in upper-carriage operation mode B
function is not carried out

595075 E/A-Modul 5: operation engine accelerator operators cab blocked in support operation mode B
function is not carried out

595076 E/A-Modul 5: operation engine accelerator op. cab blocked when auxiliary brake active or selected B
function is not carried out

595077 E/A-Modul 5: operation engine accelerator upper-carr. activated on malf. of GAS <-> E/A-Modul B
function is not carried out

595194 E/A-Modul 5: operation transmission selection of travel dir. prevented due to gear malf. "do not shift" B
function is not carried out

595195 E/A-Modul 5: operation transmission pre-selection not neutral after gear malfunction "do not shift" B
function is not carried out

596885 E/A-Modul 5: operation instruments operators cab Tempomat lever blocked in upper-carriage operation mode B
function is not carried out

596886 E/A-Modul 5: operation instruments operators cab Tempomat lever blocked in support operation mode B
function is not carried out

070645 287
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

661001 E/A-Modul 6: system error OS-C167 initialising error processor-register erroneous E 2


error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

661002 E/A-Modul 6: system error OS-C167 initialising error test total in EPROM/FLASH erroneous E 2
error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

661006 E/A-Modul 6: system error OS-C167 initialising error RAM erroneous E 2


error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

661013 E/A-Modul 6: system error OS-C167 test total in EPROM/FLASH erroneous E 2


error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

661016 E/A-Modul 6: system error OS-C167 system-, driver-watchdog expired E 2


error indication on display
note error report, ignition ON/OFF, with repeated occurrence --> inform after-sales service

661068 E/A-Modul 6: system error OS-C167 impermissible interrupt E 2


error indication on display
note error report, ignition ON/OFF, with repeated occurrence --> inform after-sales service

661071 E/A-Modul 6: system error OS-C167 Invalid configuration or Firmware E 2


error indication on display
re-load Software from ZE

661080 E/A-Modul 6: system error OS-C167 fatal internal software error E 2


error indication on display
note error report, ignition ON/OFF, with repeated occurrence --> inform after-sales service

661082 E/A-Modul 6: system error OS-C167 hardware-watchdog erroneous E 2


error indication on display
ignition ON/OFF, with repeated occurrence --> replace E/A-Modul

661088 E/A-Modul 6: system error OS-C167 Configuration does not match software condition E 1
Error output, possible error functions of module
Carry out EAM-download from LICCON

070645 288
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

661089 E/A-Modul 6: system error OS-C167 Incorrect version of firmware installed E 1


Error output, possible error functions of module
Replace module, reload firmware

661090 E/A-Modul 6: system error OS-C167 Incorrect hardware version recognised E 1


Error output, possible error functions of module
Replace module

672052 E/A-Modul 6: input/output DEA0 output open, to low load, short circuit to supply voltage X663:17 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

672053 E/A-Modul 6: input/output DEA0 transistor current supply insufficient or missing X663:17 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

672054 E/A-Modul 6: input/output DEA0 short circuit to supply voltage X663:17 E 1


error report on display
check output for short, if necessary replace E/A-Modul

672055 E/A-Modul 6: input/output DEA0 excessive temperature, short circuit to ground or overload X663:17 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

672152 E/A-Modul 6: input/output DEA1 output open, to low load, short circuit to supply voltage X663:15 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

672153 E/A-Modul 6: input/output DEA1 transistor current supply insufficient or missing X663:15 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

672154 E/A-Modul 6: input/output DEA1 short circuit to supply voltage X663:15 E 1


error report on display
check output for short, if necessary replace E/A-Modul

672155 E/A-Modul 6: input/output DEA1 excessive temperature, short circuit to ground or overload X663:15 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

070645 289
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

672252 E/A-Modul 6: input/output DEA2 output open, to low load, short circuit to supply voltage X663:13 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

672253 E/A-Modul 6: input/output DEA2 transistor current supply insufficient or missing X663:13 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

672254 E/A-Modul 6: input/output DEA2 short circuit to supply voltage X663:13 E 1


error report on display
check output for short, if necessary replace E/A-Modul

672255 E/A-Modul 6: input/output DEA2 excessive temperature, short circuit to ground or overload X663:13 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

672352 E/A-Modul 6: input/output DEA3 output open, to low load, short circuit to supply voltage X663:11 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

672353 E/A-Modul 6: input/output DEA3 transistor current supply insufficient or missing X663:11 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

672354 E/A-Modul 6: input/output DEA3 short circuit to supply voltage X663:11 E 1


error report on display
check output for short, if necessary replace E/A-Modul

672355 E/A-Modul 6: input/output DEA3 excessive temperature, short circuit to ground or overload X663:11 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

672452 E/A-Modul 6: input/output DEA4 output open, to low load, short circuit to supply voltage X663:9 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

672453 E/A-Modul 6: input/output DEA4 transistor current supply insufficient or missing X663:9 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

070645 290
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

672454 E/A-Modul 6: input/output DEA4 short circuit to supply voltage X663:9 E 1


error report on display
check output for short, if necessary replace E/A-Modul

672455 E/A-Modul 6: input/output DEA4 excessive temperature, short circuit to ground or overload X663:9 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

672552 E/A-Modul 6: input/output DEA5 output open, to low load, short circuit to supply voltage X663:7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

672553 E/A-Modul 6: input/output DEA5 transistor current supply insufficient or missing X663:7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

672554 E/A-Modul 6: input/output DEA5 short circuit to supply voltage X663:7 E 1


error report on display
check output for short, if necessary replace E/A-Modul

672555 E/A-Modul 6: input/output DEA5 excessive temperature, short circuit to ground or overload X663:7 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

672652 E/A-Modul 6: input/output DEA6 output open, to low load, short circuit to supply voltage X663:5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

672653 E/A-Modul 6: input/output DEA6 transistor current supply insufficient or missing X663:5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

672654 E/A-Modul 6: input/output DEA6 short circuit to supply voltage X663:5 E 1


error report on display
check output for short, if necessary replace E/A-Modul

672655 E/A-Modul 6: input/output DEA6 excessive temperature, short circuit to ground or overload X663:5 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

070645 291
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

672752 E/A-Modul 6: input/output DEA7 output open, to low load, short circuit to supply voltage X663:3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

672753 E/A-Modul 6: input/output DEA7 transistor current supply insufficient or missing X663:3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

672754 E/A-Modul 6: input/output DEA7 short circuit to supply voltage X663:3 E 1


error report on display
check output for short, if necessary replace E/A-Modul

672755 E/A-Modul 6: input/output DEA7 excessive temperature, short circuit to ground or overload X663:3 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

673782 E/A-Modul 6: voltage input E7 short circuit to ground, open line, constant current 10 mA incorrect X662:3 E 1
display Liccon:??? %
check input signal on the E/A-Modul or sensor

673783 E/A-Modul 6: voltage input E7 short circuit to supply voltage, open line, lack of voltage X662:3 E 1
display Liccon:??? %
check input signal on the E/A-Modul or sensor

679052 E/A-Modul 6: output A0 output open, to low load, short circuit to supply voltage X663:18 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

679053 E/A-Modul 6: output A0 transistor current supply insufficient or missing X663:18 E 1


error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

679054 E/A-Modul 6: output A0 short circuit to supply voltage X663:18 E 1


error report on display
check output for short, if necessary replace E/A-Modul

679055 E/A-Modul 6: output A0 excessive temperature, short circuit to ground or overload X663:18 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

070645 292
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

679152 E/A-Modul 6: output A1 output open, to low load, short circuit to supply voltage X663:16 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

679153 E/A-Modul 6: output A1 transistor current supply insufficient or missing X663:16 E 1


error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

679154 E/A-Modul 6: output A1 short circuit to supply voltage X663:16 E 1


error report on display
check output for short, if necessary replace E/A-Modul

679155 E/A-Modul 6: output A1 excessive temperature, short circuit to ground or overload X663:16 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

679250 E/A-Modul 6: bridge output A2 short circuit to ground, junction not supplied X663:14 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul

679251 E/A-Modul 6: bridge output A2 short circuit to supply voltage, excessive temperature X663:14 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul

679252 E/A-Modul 6: bridge output A2 output open, to low load, short circuit to supply voltage X663:14 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

679253 E/A-Modul 6: bridge output A2 transistor current supply insufficient or missing X663:14 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

679254 E/A-Modul 6: bridge output A2 short circuit to supply voltage X663:14 E 1


error report on display
check output for short, if necessary replace E/A-Modul

679255 E/A-Modul 6: bridge output A2 excessive temperature, short circuit to ground or overload X663:14 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

070645 293
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

679350 E/A-Modul 6: bridge output A3 short circuit to ground, junction not supplied X663:12 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul

679351 E/A-Modul 6: bridge output A3 short circuit to supply voltage, excessive temperature X663:12 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul

679352 E/A-Modul 6: bridge output A3 output open, to low load, short circuit to supply voltage X663:12 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

679353 E/A-Modul 6: bridge output A3 transistor current supply insufficient or missing X663:12 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

679354 E/A-Modul 6: bridge output A3 short circuit to supply voltage X663:12 E 1


error report on display
check output for short, if necessary replace E/A-Modul

679355 E/A-Modul 6: bridge output A3 excessive temperature, short circuit to ground or overload X663:12 E 1
error report on display
check output for short, current supply, check fuse of E/A-Modul, if necessary replace E/A-Modul

684104 E/A-Modul 6: LSB-B participant address 1 level exceeded X663:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

684105 E/A-Modul 6: LSB-B participant address 1 below minimum level X663:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

684118 E/A-Modul 6: LSB-B participant address 1 excess temperature X663:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

684150 E/A-Modul 6: LSB-B participant address 1 reports an incorrect sensor type X663:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

070645 294
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

684151 E/A-Modul 6: LSB-B participant address 1 was not configured for the block transfer X663:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

684153 E/A-Modul 6: LSB-B participant address 1 no longer reports or withdrawn during running period X663:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

684154 E/A-Modul 6: LSB-B participant address 1 Features other settings (parameters) as pre-entered set values X663:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

684164 E/A-Modul 6: LSB-B participant address 1 reports tolerable error in self-test X663:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

684165 E/A-Modul 6: LSB-B participant address 1 reports intolerable error in self-test X663:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

684166 E/A-Modul 6: LSB-B participant address 1 with software version, that is no longer compatible X663:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

684167 E/A-Modul 6: LSB-B participant address 1 supports no download function X663:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

684204 E/A-Modul 6: LSB-B participant address 2 level exceeded X663:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

684205 E/A-Modul 6: LSB-B participant address 2 below minimum level X663:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

684218 E/A-Modul 6: LSB-B participant address 2 excess temperature X663:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

070645 295
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

684250 E/A-Modul 6: LSB-B participant address 2 reports an incorrect sensor type X663:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

684251 E/A-Modul 6: LSB-B participant address 2 was not configured for the block transfer X663:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

684253 E/A-Modul 6: LSB-B participant address 2 no longer reports or withdrawn during running period X663:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

684254 E/A-Modul 6: LSB-B participant address 2 Features other settings (parameters) as pre-entered set values X663:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

684264 E/A-Modul 6: LSB-B participant address 2 reports tolerable error in self-test X663:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

684265 E/A-Modul 6: LSB-B participant address 2 reports intolerable error in self-test X663:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

684266 E/A-Modul 6: LSB-B participant address 2 with software version, that is no longer compatible X663:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

684267 E/A-Modul 6: LSB-B participant address 2 supports no download function X663:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

686104 E/A-Modul 6: LSB-B participant address 21 level exceeded X663:4/6 E 1


report of error, otherwise no reaction
Check sensor installation and pre-damping of sensor, clean contamination from sensor, replace sensor if faulty.

686105 E/A-Modul 6: LSB-B participant address 21 below minimum level X663:4/6 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

070645 296
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

686118 E/A-Modul 6: LSB-B participant address 21 excess temperature X663:4/6 E 0


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

686150 E/A-Modul 6: LSB-B participant address 21 reports an incorrect sensor type X663:4/6 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

686151 E/A-Modul 6: LSB-B participant address 21 was not configured for the block transfer X663:4/6 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

686153 E/A-Modul 6: LSB-B participant address 21 no longer reports or withdrawn during running period X663:4/6 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

686154 E/A-Modul 6: LSB-B participant address 21 Features other settings (parameters) as pre-entered set values X663:4/6 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

686164 E/A-Modul 6: LSB-B participant address 21 reports tolerable error in self-test X663:4/6 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, then clean, with regular occurrence replace sensor

686165 E/A-Modul 6: LSB-B participant address 21 reports intolerable error in self-test X663:4/6 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

686166 E/A-Modul 6: LSB-B participant address 21 with software version, that is no longer compatible X663:4/6 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

686167 E/A-Modul 6: LSB-B participant address 21 supports no download function X663:4/6 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

687252 E/A-Modul 6: Control data transfer LSB-B has recognised Bus collisions, communication interrupted X663:4/6 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor

070645 297
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

687255 E/A-Modul 6: Control data transfer LSB-B Bus connection faulty/defect, short circuit to supply voltage X663:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

687256 E/A-Modul 6: Control data transfer LSB-B Bus connection faulty/defect, no supply/short circuit to earth X663:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

687257 E/A-Modul 6: Control data transfer LSB-B has recognised network re-set (data transfer starts again) X663:4/6 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part

687258 E/A-Modul 6: Control data transfer LSB-B recognised participant with incorrect baud rate in bus X663:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors

687259 E/A-Modul 6: Control data transfer LSB-B recognised communication breakdown in bus X663:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network

687260 E/A-Modul 6: Control data transfer LSB-B driver error: no order to carry out X663:4/6 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software

687261 E/A-Modul 6: Control data transfer LSB-B driver error: undefined message appears X663:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination

687262 E/A-Modul 6: Control data transfer LSB-B Driver error: Initialization error X663:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination

687530 E/A-Modul 6: CAN-participant engine Data transfer subscriber transfer cycle exceeded X665:5/6 E 0
CAN-Information from participant has exceeded the defined cycle time
Check CAN network, check faulty Bus user.

687531 E/A-Modul 6: CAN-participant engine Data transfer faulty/missing, max. cycle time exceeded X665:5/6 E 1
parameterised substitute values for receiver signals will be used
Check CAN network, check faulty Bus user.

070645 298
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

689030 E/A-Modul 6: CAN-participant E/A-Modul 6 Data transfer subscriber transfer cycle exceeded X665:5/6 E 0
CAN-Transmission will be aborted
Check CAN network, replace E/A-Modul

689031 E/A-Modul 6: CAN-participant E/A-Modul 6 Data transfer faulty/missing, max. cycle time exceeded X665:5/6 E 1
CAN-Information from participant has exceeded the defined cycle time
Check CAN network, check faulty Bus user.

689900 E/A-Modul 6: Control data transfer CAN internal error at Register-check Controller X665:5/6 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul

689901 E/A-Modul 6: Control data transfer CAN internal error at RAM-check Controller X665:5/6 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul

689902 E/A-Modul 6: Control data transfer CAN Configuration error Software X665:5/6 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul, check Software (test system ZE)

689903 E/A-Modul 6: Control data transfer CAN Transfer interrupted after continuous error X665:5/6 E 1
CAN-Transmission will be aborted
Check CAN network, replace E/A-Modul

689910 E/A-Modul 6: Control data transfer CAN short-term error in bus connection X665:5/6 E 0
re-attachment of Modul to bus transmission
Check CAN network, connect individual Bus users and check if error has been remedied

689911 E/A-Modul 6: Control data transfer CAN permanent error bus connection X665:5/6 E 1
cyclic re-attachment of Modul to bus transmission
Check CAN network, connect individual Bus users and check if error has been remedied

689920 E/A-Modul 6: Control data transfer CAN active participant not responding X665:5/6 E 0
parameterised substitute values for receiver signals will be used
check error report for missing participant(s), test system ZE

689921 E/A-Modul 6: Control data transfer CAN No active subscriber responding X665:5/6 E 1
parameterised substitute values for receiver signals will be used
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul

070645 299
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

689950 E/A-Modul 6: Control data transfer CAN erroneous command test system X665:5/6 E 1
no reaction to unknown test system control command in CAN-System Software
check Software (test system)

692001 E/A-Modul 6: control engine long-term disruption E/A-Modul <-> engine control E 1
with permanent CAN-disruption engine control goes to emergency speed, ctrl. through E/A-Modul also emergency speed
After re-establishment of the CAN-communication the motor electronics remain in emergency speed --> ignition on/off

692005 E/A-Modul 6: control engine condition erroneous: CAN-signal engine ON <-> load ctrl. D+ OFF E 1

check alternator line connection to display unit, check alternator signal

692006 E/A-Modul 6: control engine condition erroneous: CAN-signal engine OFF <-> load ctrl. D+ ON E 1

check alternator line connection to display unit, check alternator signal

694190 E/A-Modul 6: LSB-bus participant ZE missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

696953 E/A-Modul 6: operation instruments crane operators cab Engine-Stop UC actuated/sticking/short circuit to supply upon start B
Key Engine-Stop without function
Release key; key sticks or signal line/entry has short-circuit to supply voltage

701000 Power supply unit: Memory card faulty, transmission error, addressing error E 2
Shut-down
Replace slide-in card

702100 Power supply unit: RAM-memory faulty, transmission error, addressing error E 2
Shut-down
Replace slide-in card, check connections ZE/bus motherboard/power supply unit

702101 Power supply unit: RAM-memory faulty, transmission error, addressing error E 2
Shut-down
Replace slide-in card, check connections ZE/bus motherboard/power supply unit

702200 Power supply unit: FLASH- memory faulty, transmission error, addressing error E 2
Shut-down
Replace slide-in card, check connections ZE/bus motherboard/power supply unit

070645 300
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

702300 Power supply unit: EEPROM- memory faulty, transmission error, addressing error E 2
Shut-down
Replace slide-in card, check connections ZE/bus motherboard/power supply unit

702400 Power supply unit: Globalbus-/QW-transmission faulty, transmission error, addressing error E 2
Shut-down
Replace slide-in card, check connections ZE/bus motherboard/power supply unit

702401 Power supply unit: Globalbus-/QW-transmission faulty, transmission error, addressing error E 2
Shut-down
Check ZE/bus motherboard/power supply unit connections

702500 Power supply unit: FLASH- memory, - module faulty, transmission error, addressing error E 2
Shut-down
Replace slide-in card, check connections ZE/bus motherboard/power supply unit

703001 Power supply unit: FPGA faulty, transmission error, addressing error E 2
Shut-down
Replace slide-in card, check connections ZE/bus motherboard/power supply unit

709002 Power supply unit: internal error Checksum (CRC) incorrect E 2


Shut-down
Replace power supply unit

709003 Power supply unit: internal error ADC-conversion faulty, processor error, time exceeded E 2
Shut-down
Replace power supply unit

709004 Power supply unit: internal error faulty/incorrect slide-in card E 2


Shut-down
Replace slide-in card

709010 Power supply unit: internal error Signal to Done-Pin incorrect (0) E 2
Shut-down
Check ZE/bus motherboard/power supply unit

709011 Power supply unit: internal error Signal to Done-Pin incorrect (1) E 2
Shut-down
Check ZE/bus motherboard/power supply unit

070645 301
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

709013 Power supply unit: internal error Register fault FPGA E 2


Shut-down
Check ZE/bus motherboard/power supply unit

709020 Power supply unit: internal error SCI transmission error, time exceeded (overrun) E 2
Shut-down
Replace power supply unit

709030 Power supply unit: internal error LCA-design time exceeded (ZE 0 faulty/missing) E 2
Shut-down
Check ZE/bus motherboard/power supply unit

709040 Power supply unit: internal error PIC time exceeded E 2


Shut-down
Replace power supply unit

709050 Power supply unit: internal error Bus controller addressing/time exceeded/data transmission (P1) E 2
Shut-down
Replace power supply unit

709060 Power supply unit: internal error Signal error "Control on" different 0, relay contact sticking E 2
Shut-down
Check plug/connections/relay

709080 Power supply unit: internal error Initialising error excess/lack of voltage E 2
Shut-down
Check voltage supply, replace power supply unit

709081 Power supply unit: internal error Lack of voltage (P0 = channel, P1 = value) E 2
Shut-down
Check voltage supply, replace power supply unit

709082 Power supply unit: internal error Excess voltage (P0 = channel, P1 = value) E 2
Shut-down
Check voltage supply, replace power supply unit

709099 Power supply unit: internal error Power supply unit off, power supply unit shut-down (note parameter) E 2
Shut-down
Replace power supply unit

070645 302
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

810160 ABV: CAN-bus system disrupted data communication X94:1/2/3 E 0


ABV function not restricted
check CAN-network, check/replace ABV-control device

810162 ABV: CAN-bus system Speed signal Tachograph to CAN faulty/missing/implausible X94:1/2/3 E 1
ABV function not restricted
check CAN-network, ABV-control device, speed signal C3, E/A-Modul 5

810163 ABV: CAN-bus system Interruption/continuous control line(s) X94:1/2/3 E 0


ABV function not restricted
check CAN-network, check/replace ABV-control device

810167 ABV: CAN-bus system CAN-communication gears faulty/not present X94:1/2/3 E 0


ABV function not restricted
check CAN-network, check/replace ABV-control device

810168 ABV: CAN-bus system CAN-communication engine erroneous/missing (ID 592) X94:1/2/3 E 0
ABV function not restricted
check CAN-network, check/replace ABV-control device

810169 ABV: CAN-bus system CAN-communication E/A-Module erroneous/missing (INS) X94:1/2/3 E 0


ABV function not restricted
check CAN-network, check/replace ABV-control device

811001 ABV: control device error or power supply Kl.15/30 excess voltage X94:7/9 E 1
ABS: inactive
check net supply control device

811002 ABV: control device error or power supply Kl.15/30 voltage below required value X94:7/9 E 1
ABS: inactive
check net supply control device

811010 ABV: control device error or power supply Kl.15/30 defect X94:7/9 E 1
ABS: inactive, ASR: inactive
replace control device

811012 ABV: control device error or power supply Kl.15/30 incorrect parameters X94:7/9 E 1
ABS: inactive, ASR: inactive
replace control device

070645 303
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

811029 ABV: control device error or power supply Kl.15/30 monitor switch time for solenoid valve actuated X94:7/9 E 0
ABS: inactive, ASR: inactive
check solenoid valve, control device

811094 ABV: control device error or power supply Kl.15/30 Wheel speeds/tyre dimensions implausible, incorrect parameterisation X94:7/9 E 1
ABS: wheel not regulated, ASR: inactive
check tires, magnet wheels, sensors

811102 ABV: control device error or power supply Kl.15/30 voltage below required value X94:7/9 E 1
ABS: inactive
check net supply control device

811103 ABV: control device error or power supply Kl.15/30 interruption X94:7/9 E 1
ABS: inactive
check net supply control device

811202 ABV: control device error or power supply Kl.15/30 voltage below required value X94:7/9 E 1
ABS: inactive
check net supply control device

811203 ABV: control device error or power supply Kl.15/30 interruption X94:7/9 E 1
ABS: inactive
check net supply control device

811602 ABV: control device error, power supply Kl.31 voltage below required value X94:10/12 E 1
ABS: inactive
check net supply control device

811609 ABV: control device error, power supply Kl.31 interruption X94:10/12 E 1
ABS: inactive
check net supply control device

811702 ABV: control device error, power supply Kl.31 voltage below required value X94:10/12 E 1
ABS: inactive
check net supply control device

811709 ABV: control device error, power supply Kl.31 interruption X94:10/12 E 1
ABS: inactive
check net supply control device

070645 304
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

812004 ABV: output longitudinal lock short circuit to ground E 1

check output, output is not connected!

812005 ABV: output longitudinal lock short circuit to supply voltage E 1

check output, output is not connected!

812103 ABV: output trailer shut-down interruption E 1

check output, output is not connected!

812104 ABV: output trailer shut-down short circuit to ground E 1

check output, output is not connected!

812105 ABV: output trailer shut-down short circuit to supply voltage E 1

check output, output is not connected!

812112 ABV: output trailer shut-down incorrect parameters E 0

check output, output is not connected!, replace control device

813020 ABV: ABS-solenoid valve front axle right interruption X96:7/8/9 E 1


ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813021 ABV: ABS-solenoid valve front axle right short circuit to ground X96:7/8/9 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813022 ABV: ABS-solenoid valve front axle right short circuit to supply voltage X96:7/8/9 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813023 ABV: ABS-solenoid valve front axle right interruption X96:7/8/9 E 1


ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

070645 305
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

813026 ABV: ABS-solenoid valve front axle right interruption X96:7/8/9 E 1


ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813027 ABV: ABS-solenoid valve front axle right short circuit to ground X96:7/8/9 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813028 ABV: ABS-solenoid valve front axle right short circuit to supply voltage X96:7/8/9 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813030 ABV: ABS-solenoid valve front axle right external control X96:7/8/9 E 2
ABS: front/rear diagonal and differential brakes inactive
check cabling, valve (ohm resistance), control device

813120 ABV: ABS-solenoid valve front axle left interruption X95:1/2/3 E 1


ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813121 ABV: ABS-solenoid valve front axle left short circuit to ground X95:1/2/3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813122 ABV: ABS-solenoid valve front axle left short circuit to supply voltage X95:1/2/3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813123 ABV: ABS-solenoid valve front axle left interruption X95:1/2/3 E 1


ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813126 ABV: ABS-solenoid valve front axle left interruption X95:1/2/3 E 1


ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813127 ABV: ABS-solenoid valve front axle left short circuit to ground X95:1/2/3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

070645 306
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

813128 ABV: ABS-solenoid valve front axle left short circuit to supply voltage X95:1/2/3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813130 ABV: ABS-solenoid valve front axle left external control X95:1/2/3 E 2
ABS: front/rear diagonal and differential brakes inactive
check cabling, valve (ohm resistance), control device

813220 ABV: ABS-solenoid valve rear axle right interruption X97:10/11/12 E 1


ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813221 ABV: ABS-solenoid valve rear axle right short circuit to ground X97:10/11/12 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813222 ABV: ABS-solenoid valve rear axle right short circuit to supply voltage X97:10/11/12 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813223 ABV: ABS-solenoid valve rear axle right interruption X97:10/11/12 E 1


ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813226 ABV: ABS-solenoid valve rear axle right interruption X97:10/11/12 E 1


ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813227 ABV: ABS-solenoid valve rear axle right short circuit to ground X97:10/11/12 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813228 ABV: ABS-solenoid valve rear axle right short circuit to supply voltage X97:10/11/12 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813230 ABV: ABS-solenoid valve rear axle right external control X97:10/11/12 E 2
ABS: front/rear diagonal and differential brakes inactive
check cabling, valve (ohm resistance), control device

070645 307
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

813320 ABV: ABS-solenoid valve rear axle left interruption X97:1/2/3 E 1


ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813321 ABV: ABS-solenoid valve rear axle left short circuit to ground X97:1/2/3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813322 ABV: ABS-solenoid valve rear axle left short circuit to supply voltage X97:1/2/3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813323 ABV: ABS-solenoid valve rear axle left interruption X97:1/2/3 E 1


ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813326 ABV: ABS-solenoid valve rear axle left interruption X97:1/2/3 E 1


ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813327 ABV: ABS-solenoid valve rear axle left short circuit to ground X97:1/2/3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813328 ABV: ABS-solenoid valve rear axle left short circuit to supply voltage X97:1/2/3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813330 ABV: ABS-solenoid valve rear axle left external control X97:1/2/3 E 2
ABS: front/rear diagonal and differential brakes inactive
check cabling, valve (ohm resistance), control device

813604 ABV: valve front axle right and rear axle left short circuit to ground X96/X97 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813605 ABV: valve front axle right and rear axle left short circuit to supply voltage X96/X97 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

070645 308
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

813704 ABV: valve front axle left and rear axle right short circuit to ground X96/X98 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813705 ABV: valve front axle left and rear axle right short circuit to supply voltage X96/X98 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813804 ABV: ASR, DIF-valve short circuit to ground X97:4/7 E 1


ASR: inactive
check cabling, valve (ohm resistance), control device

813805 ABV: ASR, DIF-valve short circuit to supply voltage X97:4/7 E 1


ASR: inactive
check cabling, valve (ohm resistance), control device

813809 ABV: ASR, DIF-valve interruption X97:4/7 E 1


ASR: inactive
check cabling, valve (ohm resistance), control device

813812 ABV: ASR, DIF-valve incorrect parameters X97:4/7 E 0


ASR: inactive
replace control device

814040 ABV: speed sensor front axle right interruption X96:4/5 E 1


ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814041 ABV: speed sensor front axle right short circuit to ground X96:4/5 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814042 ABV: speed sensor front axle right short circuit to supply voltage X96:4/5 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814044 ABV: speed sensor front axle right winding short X96:4/5 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

070645 309
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

814045 ABV: speed sensor front axle right magnet wheel defect X96:4/5 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel

814046 ABV: speed sensor front axle right sensor vibration X96:4/5 E 0
ABS: partly inactive, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel

814047 ABV: speed sensor front axle right shimmed magnet wheel X96:4/5 E 0

check magnet wheel for shimmy

814048 ABV: speed sensor front axle right Air gap, clearance sensor<>magnet wheel too large X96:4/5 E 1
ABS: wheel not regulated, ASR: inactive
check play in wheel bearing, sensor voltage, ohm resistance of cabling; push sensor on magnet wheel

814140 ABV: speed sensor front axle left interruption X95:4/5 E 1


ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814141 ABV: speed sensor front axle left short circuit to ground X95:4/5 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814142 ABV: speed sensor front axle left short circuit to supply voltage X95:4/5 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814144 ABV: speed sensor front axle left winding short X95:4/5 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814145 ABV: speed sensor front axle left magnet wheel defect X95:4/5 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel

814146 ABV: speed sensor front axle left sensor vibration X95:4/5 E 0
ABS: partly inactive, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel

070645 310
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

814147 ABV: speed sensor front axle left shimmed magnet wheel X95:4/5 E 0

check magnet wheel for shimmy

814148 ABV: speed sensor front axle left Air gap, clearance sensor<>magnet wheel too large X95:4/5 E 1
ABS: wheel not regulated, ASR: inactive
check play in wheel bearing, sensor voltage, ohm resistance of cabling; push sensor on magnet wheel

814240 ABV: speed sensor rear axle right interruption X97:8/9 E 1


ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814241 ABV: speed sensor rear axle right short circuit to ground X97:8/9 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814242 ABV: speed sensor rear axle right short circuit to supply voltage X97:8/9 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814244 ABV: speed sensor rear axle right winding short X97:8/9 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814245 ABV: speed sensor rear axle right magnet wheel defect X97:8/9 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel

814246 ABV: speed sensor rear axle right sensor vibration X97:8/9 E 0
ABS: partly inactive, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel

814247 ABV: speed sensor rear axle right shimmed magnet wheel X97:8/9 E 0

check magnet wheel for shimmy

814248 ABV: speed sensor rear axle right Air gap, clearance sensor<>magnet wheel too large X97:8/9 E 1
ABS: wheel not regulated, ASR: inactive
check play in wheel bearing, sensor voltage, ohm resistance of cabling; push sensor on magnet wheel

070645 311
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

814340 ABV: speed sensor rear axle left interruption X97:5/6 E 1


ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814341 ABV: speed sensor rear axle left short circuit to ground X97:5/6 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814342 ABV: speed sensor rear axle left short circuit to supply voltage X97:5/6 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814344 ABV: speed sensor rear axle left winding short X97:5/6 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814345 ABV: speed sensor rear axle left magnet wheel defect X97:5/6 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel

814346 ABV: speed sensor rear axle left sensor vibration X97:5/6 E 0
ABS: partly inactive, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel

814347 ABV: speed sensor rear axle left shimmed magnet wheel X97:5/6 E 0

check magnet wheel for shimmy

814348 ABV: speed sensor rear axle left Air gap, clearance sensor<>magnet wheel too large X97:5/6 E 1
ABS: wheel not regulated, ASR: inactive
check play in wheel bearing, sensor voltage, ohm resistance of cabling; push sensor on magnet wheel

821111 retarder: Output AD1 - re-circulation valve short circuit to ground X46:1 E 1
ECU no longer selects recirculation valve, response time becomes longer
RESET - otherwise check cabling between ECU and recirculation valve, check recirculation valve (internal resistance)

821112 retarder: Output AD1 - re-circulation valve short circuit to supply voltage X46:1 E 1
ECU no longer selects recirculation valve, response time becomes longer
INT OFF/ON - otherwise check cabling between ECU and recirculation valve

070645 312
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

821113 retarder: Output AD1 - re-circulation valve interruption X46:1 E 1


ECU no longer selects recirculation valve, response time becomes longer
INT AUS/AN - otherwise check cabling between ECU and recirculation valve, check recircul. valve(int. resistance)

821911 retarder: Output AIP- proportional-flow valve short circuit to ground X46:4 E 1
ECU switches off the intarder; Intarder no longer available
RESET - otherwise check cabling between ECU and proportional-flow valve, check pr.-flow valve (int. resistance)

821912 retarder: Output AIP- proportional-flow valve short circuit to supply voltage X46:4 E 1
ECU switches off the intarder; Intarder no longer available
RESET - otherwise check cabling between ECU and proportional-flow valve

821913 retarder: Output AIP- proportional-flow valve interruption X46:4 E 1


ECU switches off the intarder; Intarder no longer available
RESET - otherwise check cabling between ECU and proportional-flow valve, check pr.-flow valve (int. resistance)

821914 retarder: Output AIP- proportional-flow valve Resistance incorrect X46:4 E 1


ECU switches off the intarder; Intarder no longer available
RESET - otherwise check cabling between ECU and proportional-flow valve, check pr.-flow valve (int. resistance)

822111 retarder: Output ADM1 - Dimensions proportional-flow valve short circuit to ground X46:3 E 1
ECU switches off the intarder; Intarder no longer available
RESET - otherwise check cabling between ECU and proportional-flow valve

822112 retarder: Output ADM1 - Dimensions proportional-flow valve short circuit to supply voltage X46:3 E 1
ECU switches off the intarder; Intarder no longer available
RESET - otherwise check cabling between ECU and proportional-flow valve, check pr.-flow valve (int. resistance)

822316 retarder: Amperemeter channel proportional-flow valve Malfunction limit fallen short of X46:3/4 E 1
ECU switches off the intarder; Intarder no longer available
RESET - otherwise replace ECU

822317 retarder: Amperemeter channel proportional-flow valve Malfunction limit exceeded X46:3/4 E 1
ECU switches off the intarder; Intarder no longer available
RESET - otherwise replace ECU

823211 retarder: Input ER1 - temperature sensor short circuit to ground X46:9 E 1
ECU limits the braking action to 100 kW
INT OFF/ON - otherwise check cabling between ECU and temperature sensor, check temperature sensor (resistance)

070645 313
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

823213 retarder: Input ER1 - temperature sensor interruption X46:9 E 1


ECU limits the braking action to 100 kW
INT OFF/ON - otherwise check cabling between ECU and temperature sensor, check temperature sensor (resistance)

823318 retarder: Inputs ED1..ED5 - brake stage switch Check sum / signal(s) implausible X46:15/16/17/42 E 1
ECU reduces the set braking level under certain circumstances /43
INT OFF/ON - otherwise check cabling between ECU and brake level switch, check brake level switch

824319 retarder: CAN transmission malfunction Data transfer faulty/missing, signal error X46:22/49/21/48 E 1
no reaction
RESET - otherwise check CAN-Bus line, check shut-down resistance

824415 retarder: CAN-Bus Data transfer faulty/missing, max. cycle time exceeded X46:22/49/21/48 E 1
ECU switches off the intarder; Intarder no longer available
RESET - otherwise check CAN-Bus line

824615 retarder: CAN-Bus data transfer Data transfer faulty/missing, max. cycle time exceeded X46:22/49/21/48 E 1
no reaction
RESET - otherwise check CAN-Bus line, check shut-down resistance

825819 retarder: CAN-data transfer ABS/ASR (ID 512) Data transfer faulty/missing, signal error X46:22/49 E 1
ECU switches off the intarder; Intarder no longer available
INT OFF/ON - otherwise check ABS-ECU, check CAN-Bus line, check shut-down resistance

825919 retarder: CAN-data transfer engine (ID 592) Data transfer faulty/missing, signal error X46:22/49 E 1
ECU limits the braking action to 350 kW
INT OFF/ON - otherwise check FMR-ECU, check CAN-Bus line, check shut-down resistance

826119 retarder: CAN-data transfer engine (ID 593) Data transfer faulty/missing, signal error X46:22/49 E 1
ECU limits the braking action to 350 kW
INT OFF/ON - otherwise check FMR-ECU, check CAN-Bus line, check shut-down resistance

826219 retarder: CAN-data transfer gears (ID 556) Data transfer faulty/missing, signal error X46:22/49 E 1
ECU limits the power to 250 mA, the automatic brake (Bremsomat) is not available
INT OFF/ON - otherwise check TCU-ECU, check CAN-Bus line, check shut-down resistance

827113 retarder: Supply VPE1/VPE2 Kl.30 interruption X46:54/55 E 1


no reaction
RESET - otherwise check supply of ECU (cabling)

070645 314
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

827216 retarder: Supply VPI1/VPI2 Kl.15 Malfunction limit fallen short of X46:53/31 E 1
ECU switches off the intarder; Intarder no longer available
RESET - otherwise check mains voltage (battery, dynamo)

827217 retarder: Supply VPI1/VPI2 Kl.15 Malfunction limit exceeded X46:53/31 E 1


ECU switches off the intarder; Intarder no longer available
RESET - otherwise check mains voltage (battery, dynamo)

828218 retarder: Operating hours counter Check sum / signal(s) implausible X46 E 0
ECU resets the operating hour counter back to 0
replace ECU

828318 retarder: Error memory Check sum / signal(s) implausible X46 E 0


ECU rejects the error memory content
replace ECU

828415 retarder: System error Data transfer faulty/missing, max. cycle time exceeded X46 E 1
ECU switches off the intarder; Intarder no longer available
replace ECU

843300 heating, air cond.: Aux. heater chassis steering device error E 1

843301 heating, air cond.: Aux. heater chassis no start E 1

843302 heating, air cond.: Aux. heater chassis repeated glow interruption E 1

843303 heating, air cond.: Aux. heater chassis lack of voltage/excess voltage E 1

843304 heating, air cond.: Aux. heater chassis premature glow identification E 1

070645 315
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

843305 heating, air cond.: Aux. heater chassis glow probe interruption/short circuit E 1

843306 heating, air cond.: Aux. heater chassis temperature probe interruption/short circuit E 1

843307 heating, air cond.: Aux. heater chassis metering pump/solenoid valve interruption/short circuit E 1

843308 heating, air cond.: Aux. heater chassis blower motor interruption/short circuit/erroneous speed E 1

843309 heating, air cond.: Aux. heater chassis glow pin interruption/short circuit E 1

843310 heating, air cond.: Aux. heater chassis overheating E 1

843311 heating, air cond.: Aux. heater chassis water pump interruption/short circuit E 1

843312 heating, air cond.: Aux. heater chassis set value sensor interruption/short circuit E 1

859912 gear CLBT 755: ECU error report oil pressure or oil level insufficient J E 1
report
check oil level/oil pressure and sensor

859913 gear CLBT 755: ECU error report supply voltage to ECU insufficient J1A:2A/3A E 1
report
check 12V-supply through voltage transformer, supply lines

070645 316
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

859914 gear CLBT 755: ECU error report pressure switch for signal "forwards" defective/missing J1B:3P E 1
report
check sensor, lines

859915 gear CLBT 755: ECU error report pressure switch for signal "backwards" defective/missing J1B:1R E 1
report
check sensor, lines

859921 gear CLBT 755: ECU error report load signal TPS accelerator defective/missing J1B:1P/2P E 1
only still full- or partial load switches will be carried out, switch quality worse
check accelerator, CAN, E/A-Modul 5, ECU, lines

859922 gear CLBT 755: ECU error report output speed sensor defective/missing J1A:1L/1M E 1
report
check sensor, lines, ECU, installation sensor

859923 gear CLBT 755: ECU error report shift selector sig. (primary) from E/A-Modul 5 defective/missing J1A:1F/1H/2F/1G E 1
emergency program, perhaps gear pre-selection not possible
check ECU, E/A-Module 1+5, time relay Kl.15 ECU, lines

859924 gear CLBT 755: ECU error report oil temperature too high J1B:2L/1N E 1
report, emergency program
check cooling, sensor, ECU, lines

859931 gear CLBT 755: ECU error report shift selector signal (secondary) defective/missing J E 1
report
check ECU, cabling, no second travel switch installed!

859932 gear CLBT 755: ECU error report direction signal defective J1B:1R/3P/3N E 1

check sensor, ECU, oil temperature, lines

859933 gear CLBT 755: ECU error report oil temperature sensor outside the admissable measuring scale J1B:2L/1N E 1
report, emergency program

859934 gear CLBT 755: ECU error report internal memory test: PROM defective J1B E 1

replace ECU

070645 317
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

859941 gear CLBT 755: ECU error report solenoid valve J defective/missing J1B:3M/3L E 1
report
check ECU, valve, lines

859942 gear CLBT 755: ECU error report solenoid valve F defective/missing J1B:1W/2T E 1
report
check ECU, valve, lines

859943 gear CLBT 755: ECU error report solenoid valve D defective/missing J1B:1S/2T E 1
report
check ECU, valve, lines

859944 gear CLBT 755: ECU error report solenoid valve C defective/missing J1B:1S/3L E 1
report
check ECU, valve, lines

859945 gear CLBT 755: ECU error report solenoid valve B defective/missing J1B:1W/1T E 1
report
check ECU, valve, lines

859946 gear CLBT 755: ECU error report solenoid valve A defective/missing J1B:3T/1T E 1
report
check ECU, valve, lines

859951 gear CLBT 755: ECU error report solenoid valve G defective/missing J1B:2Y/1Y E 1
report
check ECU, valve, lines

859952 gear CLBT 755: ECU error report solenoid valve E defective/missing J1B:2W/3Y E 1
report
check ECU, valve, lines

859953 gear CLBT 755: ECU error report solenoid valve H defective/missing J1B:2M/3Y E 1
report
check ECU, valve, lines

859954 gear CLBT 755: ECU error report solenoid valve chain A, B, C, D, F, J defective J1B E 1
report
check ECU, valves, lines

070645 318
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

859966 gear CLBT 755: ECU error report bi-directional interface defective connection/transmission J1B E 1
report
incorrect ECU

859969 gear CLBT 755: ECU error report control device error/ test active J1B E 1
report
check ECU

880400 Engine chassis: CAN-Data transfer I/O-Module (ID90x) erroneous/maximum cycle time exceeded A700.X2: E 1
Emerg. op.: Momentum and RPM limitation of engine
Check cable / plug / I/O-Module(s)

880401 Engine chassis: CAN-Data transfer Coupling (ID 556) erroneous/maximum cycle time exceeded A700.X2: E 1
last received value or replacement value
Check cable / plug / coupling module

880402 Engine chassis: CAN-Data transfer Gear (ID564) erroneous/maximum cycle time exceeded A700.X2: E 1
last received value or replacement value
Check cable / plug / gear module

880403 Engine chassis: CAN-Data transfer Gear (ID564) erroneous/maximum cycle time exceeded A700.X2: E 1
last received value or replacement value
Check cable / plug / gear module

880404 Engine chassis: CAN-Data transfer Gear (ID668) erroneous/maximum cycle time exceeded A700.X2: E 1
last received value or replacement value
Check cable / plug / gear module

880405 Engine chassis: CAN-Data transfer ABV (ID512) erroneous/maximum cycle time exceeded A700.X2: E 1
last received value or replacement value
Check cable / plug / ABS/ASR-Module1

880406 Engine chassis: CAN-Data transfer ABV (ID513) erroneous/maximum cycle time exceeded A700.X2: E 1
last received value or replacement value
Check cable / plug / ABS/ASR-Module1

880407 Engine chassis: CAN-Data transfer ABV2 (ID514) erroneous/maximum cycle time exceeded A700.X2: E 1
last received value or replacement value
Check cable / plug / ABS/ASR-Module2

070645 319
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

880408 Engine chassis: CAN-Data transfer ABV2 (ID515) erroneous/maximum cycle time exceeded A700.X2: E 1
last received value or replacement value
Check cable / plug / ABS/ASR-Module2

880409 Engine chassis: CAN-Data transfer Retarder (ID 772) erroneous/maximum cycle time exceeded A700.X2: E 1
last received value or replacement value
Check cable / plug / retarder module

880410 Engine chassis: CAN-Data transfer WSK (ID 776) erroneous/maximum cycle time exceeded A700.X2: E 1
last received value or replacement value
Check cable / plug / converter module

880502 Engine chassis: CAN-engine control unit Data communication failed / interrupted (Sending timeout) A700.X2: E 1
last received value or replacement value
Check cable / plug / CAN-participant

880503 Engine chassis: CAN-engine control unit Data communication interrupted (Passive error) A700.X2: E 1
last received value or replacement value
Check cable / plug / CAN-participant

880504 Engine chassis: CAN-engine control unit Data communication interrupted (BusOff) A700.X2: E 1
last received value or replacement value
Check cable / plug / CAN-participant

880800 Engine chassis: CAN-Data transfer Data communication Tachograph problem A700.X2: E 2
Moment limitation of engine - dep. on configuration
Check cable / plug / tachograph

880801 Engine chassis: CAN-Data transfer Data communication TSC1 problem A700.X2: E 0
Engine shut off / emerg. op. - depending on configuration
Check cable / plug / CAN-participant

880802 Engine chassis: CAN-Data transfer Data communication failed / interrupted (Sending timeout) A700.X2: E 0
Engine shut off / emerg. op. - depending on configuration
Check cable / plug / CAN-participant

880803 Engine chassis: CAN-Data transfer Data communication interrupted (Passive error) A700.X2: E 2
Engine shut off / emerg. op. - depending on configuration
Check cable / plug / CAN-participant

070645 320
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

880804 Engine chassis: CAN-Data transfer Data communication interrupted (BusOff) A700.X2: E 2
Engine shut off / emerg. op. - depending on configuration
Check cable / plug / CAN-participant

881000 Engine chassis: Internal error Stack-overflow A700 E 2


Engine cannot be started or engine shut off
Turn ignition off and on, if error cannot be fixed, load new software in engine control unit or replace control unit

881001 Engine chassis: Internal error Exception A700 E 2


Engine cannot be started or engine shut off
Turn ignition off and on, if error cannot be fixed, load new software in engine control unit or replace control unit

881002 Engine chassis: Internal error Program test A700 E 2


Engine cannot be started or engine shut off
Turn ignition off and on, if error cannot be fixed, load new software in engine control unit or replace control unit

881003 Engine chassis: Internal error RAM-Test A700 E 2


Engine cannot be started or engine shut off
Turn ignition off and on, if error cannot be fixed, load new software in engine control unit or replace control unit

881004 Engine chassis: Internal error Overflow in error stack A700 E 0


No
Turn ignition off and on, if error cannot be fixed, load new software in engine control unit or replace control unit

881005 Engine chassis: Internal error Comp. time error A700 E 0


No
Turn ignition off and on, if error cannot be fixed, load new software in engine control unit or replace control unit

881006 Engine chassis: Internal error Error-Index too large A700 E 0


The error cannot be shown
Turn ignition off and on, if error cannot be fixed, load new software in engine control unit or replace control unit

881100 Engine chassis: Memory error EEPROM Error at EEPROM-access A700 E 2


Engine cannot be started or engine shut off
Turn ignition off and on, if error not fixable, replace engine control unites

881101 Engine chassis: Memory error EEPROM Check sum via parameter memory is erroneous A700 E 2
Engine cannot be started or engine shut off
Turn ignition off and on, if error not fixable, replace engine control unites

070645 321
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

881102 Engine chassis: Memory error EEPROM Parameter memory in EEPROM is invalid A700 E 2
Engine cannot be started or engine shut off
Turn ignition off and on, if error not fixable, replace engine control unites

881103 Engine chassis: Memory error EEPROM Check sum via ECU-Page is erroneous A700 E 0
No
Turn ignition off and on, if error not fixable, replace engine control unites

881104 Engine chassis: Memory error EEPROM Check sum via NMI-Page is erroneous A700 E 0
No
Turn ignition off and on, if error not fixable, replace engine control unites

881105 Engine chassis: Memory error EEPROM Check sum via Work data-Page is erroneous A700 E 0
No
Turn ignition off and on, if error not fixable, replace engine control unites

881106 Engine chassis: Memory error EEPROM Check sum via load collective is erroneous A700 E 0
No
Turn ignition off and on, if error not fixable, replace engine control unites

881107 Engine chassis: Memory error EEPROM Structure size of load collective has changed A700 E 0
No
Turn ignition off and on, if error not fixable, replace engine control unites

881108 Engine chassis: Memory error EEPROM EEPROM has insufficient memory for load collective free A700 E 0
No
Turn ignition off and on, if error not fixable, replace engine control unites

881200 Engine chassis: Power supply Supply voltage too low A700.X2: E 2
Engine cannot be started or engine shut off
Check power supply (battery, alternator, wiring, plug).

881201 Engine chassis: Power supply Supply voltage too high A700.X2: E 2
Engine cannot be started or engine shut off; only communication with diagnostics tool
Check power supply (battery, alternator, wiring, plug)

881202 Engine chassis: Power supply Digital output short circuit after supply voltage A700.X2: E 1
Engine shut off; only communication with diagnostics tool
Wiring, check engine control unit; replace engine control unit if nec.

070645 322
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

881203 Engine chassis: Power supply Error at release of power outputs A700.X2: E 1
Power outputs cannot be activated or deactivated
Wiring, check engine control unit; replace engine control unit if nec.

881204 Engine chassis: Power supply Current supply PS1 erroneous/missing A700.X2: E 2
Engine cannot be started or engine shut off
Check power supply (battery, alternator, wiring, plug) in rel. to PS1

881500 Engine chassis: Configuration error Fan control A700 E 1


The fan control is deactivated. Resulting in maximum vent position
New data set, or replace engine control unit

881501 Engine chassis: Configuration error Full load curve (incorrect Offset) A700 E 1
The power curve match is limited internally
New data set, or replace engine control unit

881502 Engine chassis: Configuration error Monitoring Travel pedal A700 E 1


Pedal unit is not monitored
New data set, or replace engine control unit

881503 Engine chassis: Configuration error Incorrect pump code A700 E 1


Injector class 3 is used as replacement value
Check pump coding and change (via diagnostics or corr. diagnostics tool)

882000 Engine chassis: Alternator Undervoltage at engine start A700.X2: E 1


No
Check wiring engine control unit to alternator and alternator.

882001 Engine chassis: Alternator Undervoltage at engine on A700.X2: E 1


No
Check wiring engine control unit to alternator and alternator.

882100 Engine chassis: Travel pedal No gas switch erroneous A700 E 1


Use low value
Check wiring engine control unit to travel pedal. Check travel pedal / replace

882101 Engine chassis: Travel pedal maximum signal difference channel 1 and 2 exceeded A700 E 1
Use low value
Check wiring engine control unit to travel pedal. Check travel pedal / replace

070645 323
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

882900 Engine chassis: Air flap Short circuit after ground or broken wire A700.X2:12/13 E 1
Air vent is not actuated
Check cable harness / plug / air vent / engine control unit

882901 Engine chassis: Air flap short circuit to supply voltage A700.X2:12/13 E 1
Air vent is not actuated
Check cable harness / plug / air vent / engine control unit

882902 Engine chassis: Air flap Hardware error (Transistor defective) A700.X2:12/13 E 1
Air vent is not actuated
Check engine control unit

882903 Engine chassis: Air flap Rule deviation negative A700.X2:12/13 E 1


Air vent is not actuated
Check cable harness / plug / air vent / engine control unit

882904 Engine chassis: Air flap Rule deviation positive A700.X2:12/13 E 1


Air vent is not actuated
Check cable harness / plug / air vent / engine control unit

882905 Engine chassis: Air flap Logic threshold breach in shut off condition A700.X2:12/13 E 1
Air vent is not actuated
Check cable harness / plug / air vent / engine control unit

882906 Engine chassis: Air flap Logic threshold breach (Current less than perm. minimum value) A700.X2:12/13 E 1
Air vent is not actuated
Check cable harness / plug / air vent / engine control unit

882907 Engine chassis: Air flap Logic threshold breach (Current more than perm. maximum value) A700.X2:12/13 E 1
Air vent is not actuated
Check cable harness / plug / air vent / engine control unit

883003 Engine chassis: High pressure pump 1 Rule deviation negative A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

883004 Engine chassis: High pressure pump 1 Rule deviation positive A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

070645 324
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

883005 Engine chassis: High pressure pump 1 Current to high in shut off condition A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

883006 Engine chassis: High pressure pump 1 Current to low in actuated condition A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

883007 Engine chassis: High pressure pump 1 Current to high in actuated condition A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

883008 Engine chassis: High pressure pump 1 UeberCurrent LowSide (ground switch ) A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

883009 Engine chassis: High pressure pump 1 UeberCurrent HighSide (Plus-switch) A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

883010 Engine chassis: High pressure pump 1 PWM on maximum A700.X1: E 2


Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

883103 Engine chassis: High pressure pump 2 Rule deviation negative A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

883104 Engine chassis: High pressure pump 2 Rule deviation positive A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

883105 Engine chassis: High pressure pump 2 Current to high in shut off condition A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

883106 Engine chassis: High pressure pump 2 Current to low in actuated condition A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

070645 325
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

883107 Engine chassis: High pressure pump 2 Current to high in actuated condition A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

883108 Engine chassis: High pressure pump 2 UeberCurrent LowSide (ground switch ) A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

883109 Engine chassis: High pressure pump 2 UeberCurrent HighSide (Plus-switch) A700.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

883110 Engine chassis: High pressure pump 2 PWM on maximum A700.X1: E 2


Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

883200 Engine chassis: Starter short circuit to ground A700.X1:29 E 1


Engine start not possible
Check cable harness / plug / Starter / engine control unit

883201 Engine chassis: Starter short circuit to supply voltage A700.X1:29 E 1


Engine start not possible
Check cable harness / plug / Starter / engine control unit

883300 Engine chassis: Fan control Short circuit after ground or broken wire A700.X2:26/27 E 1
The fan control is deactivated. Resulting in maximum vent position
Check wiring harness / plug / fan proportional valve / engine control unit

883301 Engine chassis: Fan control short circuit to supply voltage A700.X2:26/27 E 1
The fan control is deactivated. Resulting in maximum vent position
Check wiring harness / plug / fan proportional valve / engine control unit

883302 Engine chassis: Fan control Hardware error (Transistor defective) A700.X2:26/27 E 1
The fan control is deactivated. Resulting in maximum vent position
Check engine control unit

883303 Engine chassis: Fan control Rule deviation negative A700.X2:26/27 E 1


The fan control is deactivated. Resulting in maximum vent position
Check wiring harness / plug / fan proportional valve / engine control unit

070645 326
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

883304 Engine chassis: Fan control Rule deviation positive A700.X2:26/27 E 1


The fan control is deactivated. Resulting in maximum vent position
Check wiring harness / plug / fan proportional valve / engine control unit

883305 Engine chassis: Fan control Logic threshold breach in shut off condition A700.X2:26/27 E 1
The fan control is deactivated. Resulting in maximum vent position
Check wiring harness / plug / fan proportional valve / engine control unit

883306 Engine chassis: Fan control Logic threshold breach (Current less than perm. minimum value) A700.X2:26/27 E 1
The fan control is deactivated. Resulting in maximum vent position
Check wiring harness / plug / fan proportional valve / engine control unit

883307 Engine chassis: Fan control Logic threshold breach (Current more than perm. maximum value) A700.X2:26/27 E 1
The fan control is deactivated. Resulting in maximum vent position
Check wiring harness / plug / fan proportional valve / engine control unit

883400 Engine chassis: Engine brake Short circuit after ground or broken wire A700.X2:11 E 1
Engine brake flap is not actuated
Check cable harness / plug / engine brake flap / engine control unit

883401 Engine chassis: Engine brake short circuit to supply voltage A700.X2:11 E 1
Engine brake flap is not actuated
Check cable harness / plug / engine brake flap / engine control unit

883402 Engine chassis: Engine brake Hardware error (Transistor defective) A700.X2:11 E 1
Engine brake flap is not actuated
Check engine control unit

883403 Engine chassis: Engine brake Rule deviation negative A700.X2:11 E 1


Engine brake flap is not actuated
Check cable harness / plug / engine brake flap / engine control unit

883404 Engine chassis: Engine brake Rule deviation positive A700.X2:11 E 1


Engine brake flap is not actuated
Check cable harness / plug / engine brake flap / engine control unit

883405 Engine chassis: Engine brake Logic threshold breach in shut off condition A700.X2:11 E 1
Engine brake flap is not actuated
Check cable harness / plug / engine brake flap / engine control unit

070645 327
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

883406 Engine chassis: Engine brake Logic threshold breach (Current less than perm. minimum value) A700.X2:11 E 1
Engine brake flap is not actuated
Check cable harness / plug / engine brake flap / engine control unit

883407 Engine chassis: Engine brake Logic threshold breach (Current more than perm. maximum value) A700.X2:11 E 1
Engine brake flap is not actuated
Check cable harness / plug / engine brake flap / engine control unit

883500 Engine chassis: Heater flange unit 1 Short circuit after ground or broken wire A700.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

883501 Engine chassis: Heater flange unit 1 short circuit to supply voltage A700.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

883502 Engine chassis: Heater flange unit 1 Hardware error (Transistor defective) A700.X2:39/64 E 0
Failure of pre- and afterheat phase
Check engine control unit

883503 Engine chassis: Heater flange unit 1 Rule deviation negative A700.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

883504 Engine chassis: Heater flange unit 1 Rule deviation positive A700.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

883505 Engine chassis: Heater flange unit 1 Logic threshold breach in shut off condition A700.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

883506 Engine chassis: Heater flange unit 1 Logic threshold breach (Current less than perm. minimum value) A700.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

883507 Engine chassis: Heater flange unit 1 Logic threshold breach (Current more than perm. maximum value) A700.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

070645 328
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

883511 Engine chassis: Heater flange unit 1 No voltage on heater element A700.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

883512 Engine chassis: Heater flange unit 1 Voltage on heater element A700.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

883600 Engine chassis: Heater flange unit 2 Short circuit after ground or broken wire A700.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

883601 Engine chassis: Heater flange unit 2 short circuit to supply voltage A700.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

883602 Engine chassis: Heater flange unit 2 Hardware error (Transistor defective) A700.X2:25/65 E 0
Failure of pre- and afterheat phase
Check engine control unit

883603 Engine chassis: Heater flange unit 2 Rule deviation negative A700.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

883604 Engine chassis: Heater flange unit 2 Rule deviation positive A700.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

883605 Engine chassis: Heater flange unit 2 Logic threshold breach in shut off condition A700.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

883606 Engine chassis: Heater flange unit 2 Logic threshold breach (Current less than perm. minimum value) A700.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

883607 Engine chassis: Heater flange unit 2 Logic threshold breach (Current more than perm. maximum value) A700.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

070645 329
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

883611 Engine chassis: Heater flange unit 2 No voltage on heater element A700.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

883612 Engine chassis: Heater flange unit 2 Voltage on heater element A700.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

883700 Engine chassis: Solenoid valves Short circuit after ground or broken wire A700.X2:25/65 E 0
Failure of after heat phase
Check cable harness / plug / solenoid valve flame start system/ engine control unit

883701 Engine chassis: Solenoid valves short circuit to supply voltage A700.X2:25/65 E 0
Failure of after heat phase
Check cable harness / plug / solenoid valve flame start system/ engine control unit

883702 Engine chassis: Solenoid valves Hardware error (Transistor defective) A700.X2:25/65 E 0
Failure of after heat phase
Check engine control unit

883703 Engine chassis: Solenoid valves Rule deviation negative A700.X2:25/65 E 0


Failure of after heat phase
Check cable harness / plug / solenoid valve flame start system/ engine control unit

883704 Engine chassis: Solenoid valves Rule deviation positive A700.X2:25/65 E 0


Failure of after heat phase
Check cable harness / plug / solenoid valve flame start system/ engine control unit

883705 Engine chassis: Solenoid valves Logic threshold breach in shut off condition A700.X2:25/65 E 0
Failure of after heat phase
Check cable harness / plug / solenoid valve flame start system/ engine control unit

883706 Engine chassis: Solenoid valves Logic threshold breach (Current less than perm. minimum value) A700.X2:25/65 E 0
Failure of after heat phase
Check cable harness / plug / solenoid valve flame start system/ engine control unit

883707 Engine chassis: Solenoid valves Logic threshold breach (Current more than perm. maximum value) A700.X2:25/65 E 0
Failure of after heat phase
Check cable harness / plug / solenoid valve flame start system/ engine control unit

070645 330
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

883800 Engine chassis: Turbo charger Short circuit after ground or broken wire A700 E 0
Still to be defined
Check cable harness / plug / solenoid valve Turbo charger / engine control unit

883801 Engine chassis: Turbo charger short circuit to supply voltage A700 E 0
Still to be defined
Check cable harness / plug / solenoid valve Turbo charger / engine control unit

883802 Engine chassis: Turbo charger Hardware error (Transistor defective) A700 E 0
Still to be defined
Check engine control unit

883803 Engine chassis: Turbo charger Rule deviation negative A700 E 0


Still to be defined
Check cable harness / plug / solenoid valve Turbo charger / engine control unit

883804 Engine chassis: Turbo charger Rule deviation positive A700 E 0


Still to be defined
Check cable harness / plug / solenoid valve Turbo charger / engine control unit

883805 Engine chassis: Turbo charger Logic threshold breach in shut off condition A700 E 0
Still to be defined
Check cable harness / plug / solenoid valve Turbo charger / engine control unit

883806 Engine chassis: Turbo charger Logic threshold breach (Current less than perm. minimum value) A700 E 0
Still to be defined
Check cable harness / plug / solenoid valve Turbo charger / engine control unit

883807 Engine chassis: Turbo charger Logic threshold breach (Current more than perm. maximum value) A700 E 0
Still to be defined
Check cable harness / plug / solenoid valve Turbo charger / engine control unit

883900 Engine chassis: Exhaust return (AGR) Short circuit after ground or broken wire A700.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit

883901 Engine chassis: Exhaust return (AGR) short circuit to supply voltage A700.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit

070645 331
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

883902 Engine chassis: Exhaust return (AGR) Hardware error (Transistor defective) A700.X1: E 1
External AGR is not actuated
Check engine control unit

883903 Engine chassis: Exhaust return (AGR) Rule deviation negative A700.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit

883904 Engine chassis: Exhaust return (AGR) Rule deviation positive A700.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit

883905 Engine chassis: Exhaust return (AGR) Logic threshold breach (Current higher than perm. min. value) A700.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit

883906 Engine chassis: Exhaust return (AGR) Logic threshold breach (Current less than perm. minimum value) A700.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit

883907 Engine chassis: Exhaust return (AGR) Logic threshold breach (Current more than perm. maximum value) A700.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit

883911 Engine chassis: Exhaust return (AGR) open without actuation A700.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit

883912 Engine chassis: Exhaust return (AGR) closed despite actuation A700.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit

884000 Engine chassis: Emerg. Op. indicator Short circuit after ground or broken wire A700.X2:42 E 1
None
Check cable harness / plug / warn. light / engine control unit

884001 Engine chassis: Emerg. Op. indicator short circuit to supply voltage A700.X2:42 E 1
None
Check cable harness / plug / warn. light / engine control unit

070645 332
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

884002 Engine chassis: Emerg. Op. indicator Hardware error (Transistor defective) A700.X2:42 E 1
None
Check engine control unit

884100 Engine chassis: Indicator light preglow / start readiness Short circuit after ground or broken wire A700.X2:28 E 1
None
Check cable harness / plug / warn. light / engine control unit

884101 Engine chassis: Indicator light preglow / start readiness short circuit to supply voltage A700.X2:28 E 1
None
Check cable harness / plug / warn. light / engine control unit

884102 Engine chassis: Indicator light preglow / start readiness Hardware error (Transistor defective) A700.X2:28 E 1
None
Check engine control unit

884200 Engine chassis: Charge indicator Alternator Short circuit after ground or broken wire A700.X2:14 E 1
None
Check cable harness / plug / warn. light / engine control unit

884201 Engine chassis: Charge indicator Alternator short circuit to supply voltage A700.X2:14 E 1
None
Check cable harness / plug / warn. light / engine control unit

884202 Engine chassis: Charge indicator Alternator Hardware error (Transistor defective) A700.X2:14 E 1
None
Check engine control unit

884900 Engine chassis: RPM signal output Short circuit after ground or broken wire A700 E 1
None
Check cable harness / plug / connected. module

884901 Engine chassis: RPM signal output short circuit to supply voltage A700 E 1
None
Check cable harness / plug / connected. module

885000 Engine chassis: Cylinder A1 Current back test erroneous or broken wire A700.X1:22/8 E 0
No
Check cable / plug / solenoid valve / engine control unit

070645 333
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

885001 Engine chassis: Cylinder A1 UeberCurrent LowSide (ground switch ) A700.X1:22/8 E 0


No
Check cable / plug / solenoid valve / engine control unit

885002 Engine chassis: Cylinder A1 UeberCurrent HighSide (Plus switch ) A700.X1:22/8 E 0


No
Check cable / plug / solenoid valve / engine control unit

885003 Engine chassis: Cylinder A1 Overcurent HighSide (free wheel) A700.X1:22/8 E 0


No
Check cable / plug / solenoid valve / engine control unit

885004 Engine chassis: Cylinder A1 No fly time measured A700.X1:22/8 E 0


No
Replace engine control unit

885005 Engine chassis: Cylinder A1 Fly time too small A700.X1:22/8 E 0


No
Check cable / plug / solenoid valve / engine control unit

885006 Engine chassis: Cylinder A1 Fly time too large A700.X1:22/8 E 0


No
Check cable / plug / solenoid valve / engine control unit

885007 Engine chassis: Cylinder A1 No increase time measured A700.X1:22/8 E 0


No
Replace engine control unit

885008 Engine chassis: Cylinder A1 Increase time too large A700.X1:22/8 E 0


No
New data set, or replace engine control unit

885100 Engine chassis: Cylinder A2 Current back test erroneous or broken wire A700.X1:21/7 E 0
No
Check cable / plug / solenoid valve / engine control unit

885101 Engine chassis: Cylinder A2 UeberCurrent LowSide (ground switch ) A700.X1:21/7 E 0


No
Check cable / plug / solenoid valve / engine control unit

070645 334
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

885102 Engine chassis: Cylinder A2 UeberCurrent HighSide (Plus switch ) A700.X1:21/7 E 0


No
Check cable / plug / solenoid valve / engine control unit

885103 Engine chassis: Cylinder A2 Overcurent HighSide (free wheel) A700.X1:21/7 E 0


No
Check cable / plug / solenoid valve / engine control unit

885104 Engine chassis: Cylinder A2 No fly time measured A700.X1:21/7 E 0


No
Replace engine control unit

885105 Engine chassis: Cylinder A2 Fly time too small A700.X1:21/7 E 0


No
Check cable / plug / solenoid valve / engine control unit

885106 Engine chassis: Cylinder A2 Fly time too large A700.X1:21/7 E 0


No
Check cable / plug / solenoid valve / engine control unit

885107 Engine chassis: Cylinder A2 No increase time measured A700.X1:21/7 E 0


No
Replace engine control unit

885108 Engine chassis: Cylinder A2 Increase time too large A700.X1:21/7 E 0


No
New data set, or replace engine control unit

885200 Engine chassis: Cylinder A3 Current back test erroneous or broken wire A700.X1:20/6 E 0
No
Check cable / plug / solenoid valve / engine control unit

885201 Engine chassis: Cylinder A3 UeberCurrent LowSide (ground switch ) A700.X1:20/6 E 0


No
Check cable / plug / solenoid valve / engine control unit

885202 Engine chassis: Cylinder A3 UeberCurrent HighSide (Plus switch ) A700.X1:20/6 E 0


No
Check cable / plug / solenoid valve / engine control unit

070645 335
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

885203 Engine chassis: Cylinder A3 Overcurent HighSide (free wheel) A700.X1:20/6 E 0


No
Check cable / plug / solenoid valve / engine control unit

885204 Engine chassis: Cylinder A3 No fly time measured A700.X1:20/6 E 0


No
Replace engine control unit

885205 Engine chassis: Cylinder A3 Fly time too small A700.X1:20/6 E 0


No
Check cable / plug / solenoid valve / engine control unit

885206 Engine chassis: Cylinder A3 Fly time too large A700.X1:20/6 E 0


No
Check cable / plug / solenoid valve / engine control unit

885207 Engine chassis: Cylinder A3 No increase time measured A700.X1:20/6 E 0


No
Replace engine control unit

885208 Engine chassis: Cylinder A3 Increase time too large A700.X1:20/6 E 0


No
New data set, or replace engine control unit

885300 Engine chassis: Cylinder A4 Current back test erroneous or broken wire A700.X1:19/5 E 0
No
Check cable / plug / solenoid valve / engine control unit

885301 Engine chassis: Cylinder A4 UeberCurrent LowSide (ground switch ) A700.X1:19/5 E 0


No
Check cable / plug / solenoid valve / engine control unit

885302 Engine chassis: Cylinder A4 UeberCurrent HighSide (Plus switch ) A700.X1:19/5 E 0


No
Check cable / plug / solenoid valve / engine control unit

885303 Engine chassis: Cylinder A4 Overcurent HighSide (free wheel) A700.X1:19/5 E 0


No
Check cable / plug / solenoid valve / engine control unit

070645 336
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

885304 Engine chassis: Cylinder A4 No fly time measured A700.X1:19/5 E 0


No
Replace engine control unit

885305 Engine chassis: Cylinder A4 Fly time too small A700.X1:19/5 E 0


No
Check cable / plug / solenoid valve / engine control unit

885306 Engine chassis: Cylinder A4 Fly time too large A700.X1:19/5 E 0


No
Check cable / plug / solenoid valve / engine control unit

885307 Engine chassis: Cylinder A4 No increase time measured A700.X1:19/5 E 0


No
Replace engine control unit

885308 Engine chassis: Cylinder A4 Increase time too large A700.X1:19/5 E 0


No
New data set, or replace engine control unit

885800 Engine chassis: Cylinder B1 Current back test erroneous or broken wire A700.X1:18/4 E 0
No
Check cable / plug / solenoid valve / engine control unit

885801 Engine chassis: Cylinder B1 UeberCurrent LowSide (ground switch ) A700.X1:18/4 E 0


No
Check cable / plug / solenoid valve / engine control unit

885802 Engine chassis: Cylinder B1 UeberCurrent HighSide (Plus switch ) A700.X1:18/4 E 0


No
Check cable / plug / solenoid valve / engine control unit

885803 Engine chassis: Cylinder B1 Overcurent HighSide (free wheel) A700.X1:18/4 E 0


No
Check cable / plug / solenoid valve / engine control unit

885804 Engine chassis: Cylinder B1 No fly time measured A700.X1:18/4 E 0


No
Replace engine control unit

070645 337
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

885805 Engine chassis: Cylinder B1 Fly time too small A700.X1:18/4 E 0


No
Check cable / plug / solenoid valve / engine control unit

885806 Engine chassis: Cylinder B1 Fly time too large A700.X1:18/4 E 0


No
Check cable / plug / solenoid valve / engine control unit

885807 Engine chassis: Cylinder B1 No increase time measured A700.X1:18/4 E 0


No
Replace engine control unit

885808 Engine chassis: Cylinder B1 Increase time too large A700.X1:18/4 E 0


No
New data set, or replace engine control unit

885900 Engine chassis: Cylinder B2 Current back test erroneous or broken wire A700.X1:17/3 E 0
No
Check cable / plug / solenoid valve / engine control unit

885901 Engine chassis: Cylinder B2 UeberCurrent LowSide (ground switch ) A700.X1:17/3 E 0


No
Check cable / plug / solenoid valve / engine control unit

885902 Engine chassis: Cylinder B2 UeberCurrent HighSide (Plus switch ) A700.X1:17/3 E 0


No
Check cable / plug / solenoid valve / engine control unit

885903 Engine chassis: Cylinder B2 Overcurent HighSide (free wheel) A700.X1:17/3 E 0


No
Check cable / plug / solenoid valve / engine control unit

885904 Engine chassis: Cylinder B2 No fly time measured A700.X1:17/3 E 0


No
Replace engine control unit

885905 Engine chassis: Cylinder B2 Fly time too small A700.X1:17/3 E 0


No
Check cable / plug / solenoid valve / engine control unit

070645 338
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

885906 Engine chassis: Cylinder B2 Fly time too large A700.X1:17/3 E 0


No
Check cable / plug / solenoid valve / engine control unit

885907 Engine chassis: Cylinder B2 No increase time measured A700.X1:17/3 E 0


No
Replace engine control unit

885908 Engine chassis: Cylinder B2 Increase time too large A700.X1:17/3 E 0


No
New data set, or replace engine control unit

886000 Engine chassis: Cylinder B3 Current back test erroneous or broken wire A700.X1:16/2 E 0
No
Check cable / plug / solenoid valve / engine control unit

886001 Engine chassis: Cylinder B3 UeberCurrent LowSide (ground switch ) A700.X1:16/2 E 0


No
Check cable / plug / solenoid valve / engine control unit

886002 Engine chassis: Cylinder B3 UeberCurrent HighSide (Plus switch ) A700.X1:16/2 E 0


No
Check cable / plug / solenoid valve / engine control unit

886003 Engine chassis: Cylinder B3 Overcurent HighSide (free wheel) A700.X1:16/2 E 0


No
Check cable / plug / solenoid valve / engine control unit

886004 Engine chassis: Cylinder B3 No fly time measured A700.X1:16/2 E 0


No
Replace engine control unit

886005 Engine chassis: Cylinder B3 Fly time too small A700.X1:16/2 E 0


No
Check cable / plug / solenoid valve / engine control unit

886006 Engine chassis: Cylinder B3 Fly time too large A700.X1:16/2 E 0


No
Check cable / plug / solenoid valve / engine control unit

070645 339
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

886007 Engine chassis: Cylinder B3 No increase time measured A700.X1:16/2 E 0


No
Replace engine control unit

886008 Engine chassis: Cylinder B3 Increase time too large A700.X1:16/2 E 0


No
New data set, or replace engine control unit

886100 Engine chassis: Cylinder B4 Current back test erroneous or broken wire A700.X1:15/1 E 0
No
Check cable / plug / solenoid valve / engine control unit

886101 Engine chassis: Cylinder B4 UeberCurrent LowSide (ground switch ) A700.X1:15/1 E 0


No
Check cable / plug / solenoid valve / engine control unit

886102 Engine chassis: Cylinder B4 UeberCurrent HighSide (Plus switch ) A700.X1:15/1 E 0


No
Check cable / plug / solenoid valve / engine control unit

886103 Engine chassis: Cylinder B4 Overcurent HighSide (free wheel) A700.X1:15/1 E 0


No
Check cable / plug / solenoid valve / engine control unit

886104 Engine chassis: Cylinder B4 No fly time measured A700.X1:15/1 E 0


No
Replace engine control unit

886105 Engine chassis: Cylinder B4 Fly time too small A700.X1:15/1 E 0


No
Check cable / plug / solenoid valve / engine control unit

886106 Engine chassis: Cylinder B4 Fly time too large A700.X1:15/1 E 0


No
Check cable / plug / solenoid valve / engine control unit

886107 Engine chassis: Cylinder B4 No increase time measured A700.X1:15/1 E 0


No
Replace engine control unit

070645 340
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

886108 Engine chassis: Cylinder B4 Increase time too large A700.X1:15/1 E 0


No
New data set, or replace engine control unit

886900 Engine chassis: Injection system Cylinder error A700 E 2


Engine shut off, if more than permitted solenoid valve number defective, otherwise load reduction
Check cable / plug / solenoid valve / engine control unit

886901 Engine chassis: Injection system Overlap of injection on bank A A700 E 2


Engine shut off
Check injection begin and duration; Select later pre-injection start or deactivate pre-injection

886902 Engine chassis: Injection system Overlap of injection on bank B A700 E 2


Engine shut off
Check injection begin and duration; Select later pre-injection start or deactivate pre-injection

886903 Engine chassis: Injection system Short circuit Plus switch after ground on bank A A700 E 1
No
Check cable / plug / solenoid valve / engine control unit

886904 Engine chassis: Injection system Short circuit Plus switch after ground on bank B A700 E 1
No
Check cable / plug / solenoid valve / engine control unit

886905 Engine chassis: Injection system Short circuit Plus switch after supply voltage on bank A A700 E 1
No
Check cable / plug / solenoid valve / engine control unit

886906 Engine chassis: Injection system Short circuit Plus switch after supply voltage on bank B A700 E 1
No
Check cable / plug / solenoid valve / engine control unit

886907 Engine chassis: Injection system Short circuit Ground switch after ground on bank A A700 E 1
at CR-Motor occurs shut off of bank A
Check cable / plug / solenoid valve / engine control unit

886908 Engine chassis: Injection system Short circuit Ground switch after ground on bank B A700 E 1
at CR-Motor occurs shut off of bank B
Check cable / plug / solenoid valve / engine control unit

070645 341
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

886909 Engine chassis: Injection system Short circuit Ground switch after supply voltage on bank A A700 E 1
No
Check cable / plug / solenoid valve / engine control unit

886910 Engine chassis: Injection system Short circuit Ground switch after supply voltage on bank B A700 E 1
No
Check cable / plug / solenoid valve / engine control unit

887000 Engine chassis: Overspeed RPM sensor 1 Warning threshold exceeded A700 E 1
None
Check engine op. (excess. speed due to push op.); engine control unit

887001 Engine chassis: Overspeed RPM sensor 2 Warning threshold exceeded A700 E 1
None
Check engine op. (excess. speed due to push op.); engine control unit

887002 Engine chassis: Overspeed RPM sensor 1 Safety threshold exceeded A700 E 2
Engine shut off
Check engine op. (excess. speed due to push op.); engine control unit

887003 Engine chassis: Overspeed RPM sensor 2 Safety threshold exceeded A700 E 2
Engine shut off
Check engine op. (excess. speed due to push op.); engine control unit

887100 Engine chassis: Synchronization defective A700 E 1


Engine start not possible
Turn ign. on / off; check RPM and phase sensor

887101 Engine chassis: Synchronization incorrect distance gap<>Phase sensor A700 E 1


Engine start not possible
Turn ign. on / off; check RPM and phase sensor

887102 Engine chassis: Synchronization Tooth number not correct A700 E 1


Engine start not possible
Turn ign. on / off; check RPM sensor

887103 Engine chassis: Synchronization not possible, RPM is too low A700 E 1
Engine start not possible
Turn ign. on / off; check RPM and phase sensor

070645 342
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

887104 Engine chassis: Synchronization Index counter camshaft gear erroneous A700 E 1
Engine start not possible
Turn ign. on / off; check RPM and phase sensor

887200 Engine chassis: RPM sensor 1 failed A700.X1:69/55/4 E 1


Em. shut off at simult. failure of redundant sensor (1 or 2). Otherwise RPM deter. via red. sensor 1
Check: distance of RPM sensor to flywheel (0.5-2.0 mm); Wiring to RPM sensor; RPM sensor

887201 Engine chassis: RPM sensor 1 does not start A700.X1:69/55/4 E 1


Em. shut off at simult. failure of redundant sensor (1 or 2). Otherwise RPM deter. via red. sensor 1
Check: distance of RPM sensor to flywheel (0.5-2.0 mm); Wiring to RPM sensor; RPM sensor

887202 Engine chassis: RPM sensor 1 impermissible signal difference (Gradient breach) A700.X1:69/55/4 E 1
Em. shut off at simult. failure of redundant sensor (1 or 2). Otherwise RPM deter. via red. sensor 1
Check distance of RPM sensor to flywheel (0.5-2.0 mm); flywheel, wiring to RPM sensor

887203 Engine chassis: RPM sensor 1 Frequency too high A700.X1:69/55/4 E 1


Em. shut off at simult. failure of redundant sensor (1 or 2). Otherwise RPM deter. via red. sensor 1
Check distance of RPM sensor to flywheel (0.5-2.0 mm); flywheel, wiring to RPM sensor

887204 Engine chassis: RPM sensor 1 poled A700.X1:69/55/4 E 1


Em. shut off at simult. failure of redundant sensor (1 or 2). Otherwise RPM deter. via red. sensor 1
Check RPM sensor inst., engine control unit.

887300 Engine chassis: RPM sensor 2 failed A700.X1:68/54/4 E 1


Em. shut off at simult. failure of redundant sensor (1 or 2). Otherwise RPM deter. via red. sensor 0
Check: distance of RPM sensor to flywheel (0.5-2.0 mm); Wiring to RPM sensor; RPM sensor

887301 Engine chassis: RPM sensor 2 does not start A700.X1:68/54/4 E 1


Em. shut off at simult. failure of redundant sensor (1 or 2). Otherwise RPM deter. via red. sensor 0
Check: distance of RPM sensor to flywheel (0.5-2.0 mm); Wiring to RPM sensor; RPM sensor

887302 Engine chassis: RPM sensor 2 impermissible signal difference (Gradient breach) A700.X1:68/54/4 E 1
Em. shut off at simult. failure of redundant sensor (1 or 2). Otherwise RPM deter. via red. sensor 0
Check distance of RPM sensor to flywheel (0.5-2.0 mm); flywheel, wiring to RPM sensor

887303 Engine chassis: RPM sensor 2 Frequency too high A700.X1:68/54/4 E 1


Em. shut off at simult. failure of redundant sensor (1 or 2). Otherwise RPM deter. via red. sensor 0
Check distance of RPM sensor to flywheel (0.5-2.0 mm); flywheel, wiring to RPM sensor

070645 343
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

887304 Engine chassis: RPM sensor 2 poled A700.X1:68/54/4 E 1


Em. shut off at simult. failure of redundant sensor (1 or 2). Otherwise RPM deter. via red. sensor 0
Check RPM sensor inst., engine control unit.

887400 Engine chassis: Sensor Position camshaft failed A700.X1:70/56/4 E 1


Engine start, dep. on configuration, not possible. No effect with engine running 2
Check distance of phase sensor to camshaft gear (0.5-2.0 mm); wiring to phase sensor, phase sensor

887500 Engine chassis: Travel pedal channel 1 Short circuit after ground or line interruption A700.X2:33/34/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)

887501 Engine chassis: Travel pedal channel 1 short circuit to supply voltage A700.X2:33/34/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

887502 Engine chassis: Travel pedal channel 1 Supply voltage Short circuit after ground A700.X2:33/34/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring engine control unit/Sensor (Short circuit after ground)

887503 Engine chassis: Travel pedal channel 1 Supply voltage Short circuit after supply voltage A700.X2:33/34/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

887504 Engine chassis: Travel pedal channel 1 Signal outside permissible range (Limit 1) A700.X2:33/34/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 5
Check medium for operating range problem. If nec., remedy mechanical problem

887505 Engine chassis: Travel pedal channel 1 Signal outside permissible range (Limit 2) A700.X2:33/34/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 5
Check medium for operating range problem. If nec., remedy mechanical problem

887600 Engine chassis: Travel pedal channel 2 Short circuit after ground or line interruption A700.X2:47/48/4 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 9
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)

887601 Engine chassis: Travel pedal channel 2 short circuit to supply voltage A700.X2:47/48/4 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 9
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

070645 344
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

887602 Engine chassis: Travel pedal channel 2 Supply voltage Short circuit after ground A700.X2:47/48/4 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 9
Check wiring engine control unit/Sensor (Short circuit after ground)

887603 Engine chassis: Travel pedal channel 2 Supply voltage Short circuit after supply voltage A700.X2:47/48/4 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 9
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

887604 Engine chassis: Travel pedal channel 2 Signal outside permissible range (Limit 1) A700.X2:47/48/4 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 9
Check medium for operating range problem. If nec., remedy mechanical problem

887605 Engine chassis: Travel pedal channel 2 Signal outside permissible range (Limit 2) A700.X2:47/48/4 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 9
Check medium for operating range problem. If nec., remedy mechanical problem

887700 Engine chassis: Sensor coolant level Short circuit after ground or line interruption A700.X2:19/20/2 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)

887701 Engine chassis: Sensor coolant level short circuit to supply voltage A700.X2:19/20/2 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

887702 Engine chassis: Sensor coolant level Supply voltage Short circuit after ground A700.X2:19/20/2 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring engine control unit/Sensor (Short circuit after ground)

887703 Engine chassis: Sensor coolant level Supply voltage Short circuit after supply voltage A700.X2:19/20/2 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

887704 Engine chassis: Sensor coolant level Signal outside permissible range (Limit 1) A700.X2:19/20/2 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 1
Check medium for operating range problem. If nec., remedy mechanical problem

887705 Engine chassis: Sensor coolant level Signal outside permissible range (Limit 2) A700.X2:19/20/2 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 1
Check medium for operating range problem. If nec., remedy mechanical problem

070645 345
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

887800 Engine chassis: Sensor oil level Short circuit after ground or line interruption A700 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)

887801 Engine chassis: Sensor oil level short circuit to supply voltage A700 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

887802 Engine chassis: Sensor oil level Supply voltage Short circuit after ground A700 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

887803 Engine chassis: Sensor oil level Supply voltage Short circuit after supply voltage A700 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

887804 Engine chassis: Sensor oil level Signal outside permissible range (Limit 1) A700 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

887805 Engine chassis: Sensor oil level Signal outside permissible range (Limit 2) A700 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

888400 Engine chassis: Sensor charge air pr, Short circuit after ground or line interruption A700.X1:61/47/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 3
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)

888401 Engine chassis: Sensor charge air pr, short circuit to supply voltage A700.X1:61/47/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 3
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

888402 Engine chassis: Sensor charge air pr, Supply voltage Short circuit after ground A700.X1:61/47/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 3
Check wiring engine control unit/Sensor (Short circuit after ground)

888403 Engine chassis: Sensor charge air pr, Supply voltage Short circuit after supply voltage A700.X1:61/47/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 3
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

070645 346
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

888404 Engine chassis: Sensor charge air pr, Signal outside permissible range (Limit 1) A700.X1:61/47/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 3
Check medium for operating range problem. If nec., remedy mechanical problem

888405 Engine chassis: Sensor charge air pr, Signal outside permissible range (Limit 2) A700.X1:61/47/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 3
Check medium for operating range problem. If nec., remedy mechanical problem

888500 Engine chassis: Sensor oil pr. Short circuit after ground or line interruption A700.X1:63/49/3 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)

888501 Engine chassis: Sensor oil pr. short circuit to supply voltage A700.X1:63/49/3 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

888502 Engine chassis: Sensor oil pr. Supply voltage Short circuit after ground A700.X1:63/49/3 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring engine control unit/Sensor (Short circuit after ground)

888503 Engine chassis: Sensor oil pr. Supply voltage Short circuit after supply voltage A700.X1:63/49/3 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

888504 Engine chassis: Sensor oil pr. Signal outside permissible range (Limit 1) A700.X1:63/49/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 5
Check medium for operating range problem. If nec., remedy mechanical problem

888505 Engine chassis: Sensor oil pr. Signal outside permissible range (Limit 2) A700.X1:63/49/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 5
Check medium for operating range problem. If nec., remedy mechanical problem

888600 Engine chassis: Sensor fuel pr. Short circuit after ground or line interruption A700.X1:62/48/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 4
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)

888601 Engine chassis: Sensor fuel pr. short circuit to supply voltage A700.X1:62/48/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 4
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

070645 347
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

888602 Engine chassis: Sensor fuel pr. Supply voltage Short circuit after ground A700.X1:62/48/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 4
Check wiring engine control unit/Sensor (Short circuit after ground)

888603 Engine chassis: Sensor fuel pr. Supply voltage Short circuit after supply voltage A700.X1:62/48/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 4
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

888604 Engine chassis: Sensor fuel pr. Signal outside permissible range (Limit 1) A700.X1:62/48/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 4
Check medium for operating range problem. If nec., remedy mechanical problem

888605 Engine chassis: Sensor fuel pr. Signal outside permissible range (Limit 2) A700.X1:62/48/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 4
Check medium for operating range problem. If nec., remedy mechanical problem

888700 Engine chassis: Sensor Air filter contamination Short circuit after ground or line interruption A700.X2:5/6/7 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)

888701 Engine chassis: Sensor Air filter contamination short circuit to supply voltage A700.X2:5/6/7 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

888702 Engine chassis: Sensor Air filter contamination Supply voltage Short circuit after ground A700.X2:5/6/7 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

888703 Engine chassis: Sensor Air filter contamination Supply voltage Short circuit after supply voltage A700.X2:5/6/7 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

888704 Engine chassis: Sensor Air filter contamination Signal outside permissible range (Limit 1) A700.X2:5/6/7 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

888705 Engine chassis: Sensor Air filter contamination Signal outside permissible range (Limit 2) A700.X2:5/6/7 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

070645 348
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

888800 Engine chassis: Common Rail Pr. sensor 1 Short circuit after ground or line interruption A700.X1:60/46/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 2
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)

888801 Engine chassis: Common Rail Pr. sensor 1 short circuit to supply voltage A700.X1:60/46/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 2
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

888802 Engine chassis: Common Rail Pr. sensor 1 Supply voltage Short circuit after ground A700.X1:60/46/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 2
Check wiring engine control unit/Sensor (Short circuit after ground)

888803 Engine chassis: Common Rail Pr. sensor 1 Supply voltage Short circuit after supply voltage A700.X1:60/46/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 2
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

888804 Engine chassis: Common Rail Pr. sensor 1 Signal outside permissible range (Limit 1) A700.X1:60/46/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 2
Check medium for operating range problem. If nec., remedy mechanical problem

888805 Engine chassis: Common Rail Pr. sensor 1 Signal outside permissible range (Limit 2) A700.X1:60/46/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 2
Check medium for operating range problem. If nec., remedy mechanical problem

888900 Engine chassis: Common Rail Pr. sensor 2 Short circuit after ground or line interruption A700.X1:59/45/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)

888901 Engine chassis: Common Rail Pr. sensor 2 short circuit to supply voltage A700.X1:59/45/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

888902 Engine chassis: Common Rail Pr. sensor 2 Supply voltage Short circuit after ground A700.X1:59/45/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring engine control unit/Sensor (Short circuit after ground)

888903 Engine chassis: Common Rail Pr. sensor 2 Supply voltage Short circuit after supply voltage A700.X1:59/45/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

070645 349
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

888904 Engine chassis: Common Rail Pr. sensor 2 Signal outside permissible range (Limit 1) A700.X1:59/45/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 1
Check medium for operating range problem. If nec., remedy mechanical problem

888905 Engine chassis: Common Rail Pr. sensor 2 Signal outside permissible range (Limit 2) A700.X1:59/45/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 1
Check medium for operating range problem. If nec., remedy mechanical problem

889000 Engine chassis: Sensor ambient pr. Short circuit after ground or line interruption A700 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)

889001 Engine chassis: Sensor ambient pr. short circuit to supply voltage A700 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

889002 Engine chassis: Sensor ambient pr. Supply voltage Short circuit after ground A700 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

889003 Engine chassis: Sensor ambient pr. Supply voltage Short circuit after supply voltage A700 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

889300 Engine chassis: Sensor Water in fuel short circuit to ground A700.X2: E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

889301 Engine chassis: Sensor Water in fuel short circuit to supply voltage A700.X2: E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)

889302 Engine chassis: Sensor Water in fuel Supply voltage Short circuit after ground A700.X2: E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

889303 Engine chassis: Sensor Water in fuel Supply voltage Short circuit after supply voltage A700.X2: E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

070645 350
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

889304 Engine chassis: Sensor Water in fuel Signal outside permissible range (Limit 1) A700.X2: E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

889305 Engine chassis: Sensor Water in fuel Signal outside permissible range (Limit 2) A700.X2: E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

889400 Engine chassis: Sensor Intercooler-Temperature short circuit to ground A700.X2: E 1


Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

889401 Engine chassis: Sensor Intercooler-Temperature short circuit to supply voltage A700.X2: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)

889402 Engine chassis: Sensor Intercooler-Temperature Supply voltage Short circuit after ground A700.X2: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

889403 Engine chassis: Sensor Intercooler-Temperature Supply voltage Short circuit after supply voltage A700.X2: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

889404 Engine chassis: Sensor Intercooler-Temperature Signal outside permissible range (Limit 1) A700.X2: E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

889405 Engine chassis: Sensor Intercooler-Temperature Signal outside permissible range (Limit 2) A700.X2: E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

889500 Engine chassis: Oil temperature sensor short circuit to ground A700.X2:46/60 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

889501 Engine chassis: Oil temperature sensor short circuit to supply voltage A700.X2:46/60 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)

070645 351
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

889502 Engine chassis: Oil temperature sensor Supply voltage Short circuit after ground A700.X2:46/60 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

889503 Engine chassis: Oil temperature sensor Supply voltage Short circuit after supply voltage A700.X2:46/60 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

889504 Engine chassis: Oil temperature sensor Signal outside permissible range (Limit 1) A700.X2:46/60 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

889505 Engine chassis: Oil temperature sensor Signal outside permissible range (Limit 2) A700.X2:46/60 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

889600 Engine chassis: Sensor fuel temperature short circuit to ground A700.X1:38/52 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

889601 Engine chassis: Sensor fuel temperature short circuit to supply voltage A700.X1:38/52 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)

889602 Engine chassis: Sensor fuel temperature Supply voltage Short circuit after ground A700.X1:38/52 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

889603 Engine chassis: Sensor fuel temperature Supply voltage Short circuit after supply voltage A700.X1:38/52 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

889604 Engine chassis: Sensor fuel temperature Signal outside permissible range (Limit 1) A700.X1:38/52 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

889605 Engine chassis: Sensor fuel temperature Signal outside permissible range (Limit 2) A700.X1:38/52 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

070645 352
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

889700 Engine chassis: Sensor charge air temperature short circuit to ground A700.X1: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

889701 Engine chassis: Sensor charge air temperature short circuit to supply voltage A700.X1: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)

889702 Engine chassis: Sensor charge air temperature Supply voltage Short circuit after ground A700.X1: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

889703 Engine chassis: Sensor charge air temperature Supply voltage Short circuit after supply voltage A700.X1: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

889704 Engine chassis: Sensor charge air temperature Signal outside permissible range (Limit 1) A700.X1: E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

889705 Engine chassis: Sensor charge air temperature Signal outside permissible range (Limit 2) A700.X1: E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

889800 Engine chassis: Sensor coolant temperature short circuit to ground A700.X1:51/37 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

889801 Engine chassis: Sensor coolant temperature short circuit to supply voltage A700.X1:51/37 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)

889802 Engine chassis: Sensor coolant temperature Supply voltage Short circuit after ground A700.X1:51/37 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

889803 Engine chassis: Sensor coolant temperature Supply voltage Short circuit after supply voltage A700.X1:51/37 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

070645 353
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

889804 Engine chassis: Sensor coolant temperature Signal outside permissible range (Limit 1) A700.X1:51/37 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

889805 Engine chassis: Sensor coolant temperature Signal outside permissible range (Limit 2) A700.X1:51/37 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

889900 Engine chassis: Sensor internal temperature short circuit to ground A700 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

889901 Engine chassis: Sensor internal temperature short circuit to supply voltage A700 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)

889902 Engine chassis: Sensor internal temperature Supply voltage Short circuit after ground A700 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

889903 Engine chassis: Sensor internal temperature Supply voltage Short circuit after supply voltage A700 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

889904 Engine chassis: Sensor internal temperature Signal outside permissible range (Limit 1) A700 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

889905 Engine chassis: Sensor internal temperature Signal outside permissible range (Limit 2) A700 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

890400 Engine uppercarr. CAN-Data transfer I/O-Module (ID90x) erroneous/maximum cycle time exceeded A750.X2: E 1
Emerg. op.: Momentum and RPM limitation of engine
Check cable / plug / I/O-Module(s)

890401 Engine uppercarr. CAN-Data transfer Coupling (ID 556) erroneous/maximum cycle time exceeded A750.X2: E 1
last received value or replacement value
Check cable / plug / coupling module

070645 354
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

890402 Engine uppercarr. CAN-Data transfer Gear (ID564) erroneous/maximum cycle time exceeded A750.X2: E 1
last received value or replacement value
Check cable / plug / gear module

890403 Engine uppercarr. CAN-Data transfer Gear (ID564) erroneous/maximum cycle time exceeded A750.X2: E 1
last received value or replacement value
Check cable / plug / gear module

890404 Engine uppercarr. CAN-Data transfer Gear (ID668) erroneous/maximum cycle time exceeded A750.X2: E 1
last received value or replacement value
Check cable / plug / gear module

890405 Engine uppercarr. CAN-Data transfer ABV (ID512) erroneous/maximum cycle time exceeded A750.X2: E 1
last received value or replacement value
Check cable / plug / ABS/ASR-Module1

890406 Engine uppercarr. CAN-Data transfer ABV (ID513) erroneous/maximum cycle time exceeded A750.X2: E 1
last received value or replacement value
Check cable / plug / ABS/ASR-Module1

890407 Engine uppercarr. CAN-Data transfer ABV2 (ID514) erroneous/maximum cycle time exceeded A750.X2: E 1
last received value or replacement value
Check cable / plug / ABS/ASR-Module2

890408 Engine uppercarr. CAN-Data transfer ABV2 (ID515) erroneous/maximum cycle time exceeded A750.X2: E 1
last received value or replacement value
Check cable / plug / ABS/ASR-Module2

890409 Engine uppercarr. CAN-Data transfer Retarder (ID 772) erroneous/maximum cycle time exceeded A750.X2: E 1
last received value or replacement value
Check cable / plug / retarder module

890410 Engine uppercarr. CAN-Data transfer WSK (ID 776) erroneous/maximum cycle time exceeded A750.X2: E 1
last received value or replacement value
Check cable / plug / converter module

890502 Engine uppercarr. CAN-engine control unit Data communication failed / interrupted (Sending timeout) A750.X2: E 1
last received value or replacement value
Check cable / plug / CAN-participant

070645 355
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

890503 Engine uppercarr. CAN-engine control unit Data communication interrupted (Passive error) A750.X2: E 1
last received value or replacement value
Check cable / plug / CAN-participant

890504 Engine uppercarr. CAN-engine control unit Data communication interrupted (BusOff) A750.X2: E 1
last received value or replacement value
Check cable / plug / CAN-participant

890800 Engine uppercarr. CAN-Data transfer Data communication Tachograph problem A750.X2: E 2
Moment limitation of engine - dep. on configuration
Check cable / plug / tachograph

890801 Engine uppercarr. CAN-Data transfer Data communication TSC1 problem A750.X2: E 0
Engine shut off / emerg. op. - depending on configuration
Check cable / plug / CAN-participant

890802 Engine uppercarr. CAN-Data transfer Data communication failed / interrupted (Sending timeout) A750.X2: E 0
Engine shut off / emerg. op. - depending on configuration
Check cable / plug / CAN-participant

890803 Engine uppercarr. CAN-Data transfer Data communication interrupted (Passive error) A750.X2: E 2
Engine shut off / emerg. op. - depending on configuration
Check cable / plug / CAN-participant

890804 Engine uppercarr. CAN-Data transfer Data communication interrupted (BusOff) A750.X2: E 2
Engine shut off / emerg. op. - depending on configuration
Check cable / plug / CAN-participant

891000 Engine uppercarr. Internal error Stack-overflow A750 E 2


Engine cannot be started or engine shut off
Turn ignition off and on, if error cannot be fixed, load new software in engine control unit or replace control unit

891001 Engine uppercarr. Internal error Exception A750 E 2


Engine cannot be started or engine shut off
Turn ignition off and on, if error cannot be fixed, load new software in engine control unit or replace control unit

891002 Engine uppercarr. Internal error Program test A750 E 2


Engine cannot be started or engine shut off
Turn ignition off and on, if error cannot be fixed, load new software in engine control unit or replace control unit

070645 356
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

891003 Engine uppercarr. Internal error RAM-Test A750 E 2


Engine cannot be started or engine shut off
Turn ignition off and on, if error cannot be fixed, load new software in engine control unit or replace control unit

891004 Engine uppercarr. Internal error Overflow in error stack A750 E 0


No
Turn ignition off and on, if error cannot be fixed, load new software in engine control unit or replace control unit

891005 Engine uppercarr. Internal error Comp. time error A750 E 0


No
Turn ignition off and on, if error cannot be fixed, load new software in engine control unit or replace control unit

891006 Engine uppercarr. Internal error Error-Index too large A750 E 0


The error cannot be shown
Turn ignition off and on, if error cannot be fixed, load new software in engine control unit or replace control unit

891100 Engine uppercarr. Memory error EEPROM Error at EEPROM-access A750 E 2


Engine cannot be started or engine shut off
Turn ignition off and on, if error not fixable, replace engine control unites

891101 Engine uppercarr. Memory error EEPROM Check sum via parameter memory is erroneous A750 E 2
Engine cannot be started or engine shut off
Turn ignition off and on, if error not fixable, replace engine control unites

891102 Engine uppercarr. Memory error EEPROM Parameter memory in EEPROM is invalid A750 E 2
Engine cannot be started or engine shut off
Turn ignition off and on, if error not fixable, replace engine control unites

891103 Engine uppercarr. Memory error EEPROM Check sum via ECU-Page is erroneous A750 E 0
No
Turn ignition off and on, if error not fixable, replace engine control unites

891104 Engine uppercarr. Memory error EEPROM Check sum via NMI-Page is erroneous A750 E 0
No
Turn ignition off and on, if error not fixable, replace engine control unites

891105 Engine uppercarr. Memory error EEPROM Check sum via Work data-Page is erroneous A750 E 0
No
Turn ignition off and on, if error not fixable, replace engine control unites

070645 357
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

891106 Engine uppercarr. Memory error EEPROM Check sum via load collective is erroneous A750 E 0
No
Turn ignition off and on, if error not fixable, replace engine control unites

891107 Engine uppercarr. Memory error EEPROM Structure size of load collective has changed A750 E 0
No
Turn ignition off and on, if error not fixable, replace engine control unites

891108 Engine uppercarr. Memory error EEPROM EEPROM has insufficient memory for load collective free A750 E 0
No
Turn ignition off and on, if error not fixable, replace engine control unites

891200 Engine uppercarr. Power supply Supply voltage too low A750.X2: E 2
Engine cannot be started or engine shut off
Check power supply (battery, alternator, wiring, plug).

891201 Engine uppercarr. Power supply Supply voltage too high A750.X2: E 2
Engine cannot be started or engine shut off; only communication with diagnostics tool
Check power supply (battery, alternator, wiring, plug)

891202 Engine uppercarr. Power supply Digital output short circuit after supply voltage A750.X2: E 1
Engine shut off; only communication with diagnostics tool
Wiring, check engine control unit; replace engine control unit if nec.

891203 Engine uppercarr. Power supply Error at release of power outputs A750.X2: E 1
Power outputs cannot be activated or deactivated
Wiring, check engine control unit; replace engine control unit if nec.

891204 Engine uppercarr. Power supply Current supply PS1 erroneous/missing A750.X2: E 2
Engine cannot be started or engine shut off
Check power supply (battery, alternator, wiring, plug) in rel. to PS1

891500 Engine uppercarr. Configuration error Fan control A750 E 1


The fan control is deactivated. Resulting in maximum vent position
New data set, or replace engine control unit

891501 Engine uppercarr. Configuration error Full load curve (incorrect Offset) A750 E 1
The power curve match is limited internally
New data set, or replace engine control unit

070645 358
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

891502 Engine uppercarr. Configuration error Monitoring Travel pedal A750 E 1


Pedal unit is not monitored
New data set, or replace engine control unit

891503 Engine uppercarr. Configuration error Incorrect pump code A750 E 1


Injector class 3 is used as replacement value
Check pump coding and change (via diagnostics or corr. diagnostics tool)

892000 Engine uppercarr. Alternator Undervoltage at engine start A750.X2: E 1


No
Check wiring engine control unit to alternator and alternator.

892001 Engine uppercarr. Alternator Undervoltage at engine on A750.X2: E 1


No
Check wiring engine control unit to alternator and alternator.

892100 Engine uppercarr. Travel pedal No gas switch erroneous A750 E 1


Use low value
Check wiring engine control unit to travel pedal. Check travel pedal / replace

892101 Engine uppercarr. Travel pedal maximum signal difference channel 1 and 2 exceeded A750 E 1
Use low value
Check wiring engine control unit to travel pedal. Check travel pedal / replace

892900 Engine uppercarr. Air flap Short circuit after ground or broken wire A750.X2:12/13 E 1
Air vent is not actuated
Check cable harness / plug / air vent / engine control unit

892901 Engine uppercarr. Air flap short circuit to supply voltage A750.X2:12/13 E 1
Air vent is not actuated
Check cable harness / plug / air vent / engine control unit

892902 Engine uppercarr. Air flap Hardware error (Transistor defective) A750.X2:12/13 E 1
Air vent is not actuated
Check engine control unit

892903 Engine uppercarr. Air flap Rule deviation negative A750.X2:12/13 E 1


Air vent is not actuated
Check cable harness / plug / air vent / engine control unit

070645 359
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

892904 Engine uppercarr. Air flap Rule deviation positive A750.X2:12/13 E 1


Air vent is not actuated
Check cable harness / plug / air vent / engine control unit

892905 Engine uppercarr. Air flap Logic threshold breach in shut off condition A750.X2:12/13 E 1
Air vent is not actuated
Check cable harness / plug / air vent / engine control unit

892906 Engine uppercarr. Air flap Logic threshold breach (Current less than perm. minimum value) A750.X2:12/13 E 1
Air vent is not actuated
Check cable harness / plug / air vent / engine control unit

892907 Engine uppercarr. Air flap Logic threshold breach (Current more than perm. maximum value) A750.X2:12/13 E 1
Air vent is not actuated
Check cable harness / plug / air vent / engine control unit

893003 Engine uppercarr. High pressure pump 1 Rule deviation negative A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

893004 Engine uppercarr. High pressure pump 1 Rule deviation positive A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

893005 Engine uppercarr. High pressure pump 1 Current to high in shut off condition A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

893006 Engine uppercarr. High pressure pump 1 Current to low in actuated condition A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

893007 Engine uppercarr. High pressure pump 1 Current to high in actuated condition A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

893008 Engine uppercarr. High pressure pump 1 UeberCurrent LowSide (ground switch ) A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

070645 360
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

893009 Engine uppercarr. High pressure pump 1 UeberCurrent HighSide (Plus-switch) A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

893010 Engine uppercarr. High pressure pump 1 PWM on maximum A750.X1: E 2


Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

893103 Engine uppercarr. High pressure pump 2 Rule deviation negative A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

893104 Engine uppercarr. High pressure pump 2 Rule deviation positive A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

893105 Engine uppercarr. High pressure pump 2 Current to high in shut off condition A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

893106 Engine uppercarr. High pressure pump 2 Current to low in actuated condition A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

893107 Engine uppercarr. High pressure pump 2 Current to high in actuated condition A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

893108 Engine uppercarr. High pressure pump 2 UeberCurrent LowSide (ground switch ) A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

893109 Engine uppercarr. High pressure pump 2 UeberCurrent HighSide (Plus-switch) A750.X1: E 2
Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

893110 Engine uppercarr. High pressure pump 2 PWM on maximum A750.X1: E 2


Emerg. op.: Shut off of CR-High pr. pump
Check cable harness / plug / CR-High pr. pump / engine control unit

070645 361
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

893200 Engine uppercarr. Starter short circuit to ground A750.X1:29 E 1


Engine start not possible
Check cable harness / plug / Starter / engine control unit

893201 Engine uppercarr. Starter short circuit to supply voltage A750.X1:29 E 1


Engine start not possible
Check cable harness / plug / Starter / engine control unit

893300 Engine uppercarr. Fan control Short circuit after ground or broken wire A750.X2:26/27 E 1
The fan control is deactivated. Resulting in maximum vent position
Check wiring harness / plug / fan proportional valve / engine control unit

893301 Engine uppercarr. Fan control short circuit to supply voltage A750.X2:26/27 E 1
The fan control is deactivated. Resulting in maximum vent position
Check wiring harness / plug / fan proportional valve / engine control unit

893302 Engine uppercarr. Fan control Hardware error (Transistor defective) A750.X2:26/27 E 1
The fan control is deactivated. Resulting in maximum vent position
Check engine control unit

893303 Engine uppercarr. Fan control Rule deviation negative A750.X2:26/27 E 1


The fan control is deactivated. Resulting in maximum vent position
Check wiring harness / plug / fan proportional valve / engine control unit

893304 Engine uppercarr. Fan control Rule deviation positive A750.X2:26/27 E 1


The fan control is deactivated. Resulting in maximum vent position
Check wiring harness / plug / fan proportional valve / engine control unit

893305 Engine uppercarr. Fan control Logic threshold breach in shut off condition A750.X2:26/27 E 1
The fan control is deactivated. Resulting in maximum vent position
Check wiring harness / plug / fan proportional valve / engine control unit

893306 Engine uppercarr. Fan control Logic threshold breach (Current less than perm. minimum value) A750.X2:26/27 E 1
The fan control is deactivated. Resulting in maximum vent position
Check wiring harness / plug / fan proportional valve / engine control unit

893307 Engine uppercarr. Fan control Logic threshold breach (Current more than perm. maximum value) A750.X2:26/27 E 1
The fan control is deactivated. Resulting in maximum vent position
Check wiring harness / plug / fan proportional valve / engine control unit

070645 362
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

893400 Engine uppercarr. Engine brake Short circuit after ground or broken wire A750.X2:11 E 1
Engine brake flap is not actuated
Check cable harness / plug / engine brake flap / engine control unit

893401 Engine uppercarr. Engine brake short circuit to supply voltage A750.X2:11 E 1
Engine brake flap is not actuated
Check cable harness / plug / engine brake flap / engine control unit

893402 Engine uppercarr. Engine brake Hardware error (Transistor defective) A750.X2:11 E 1
Engine brake flap is not actuated
Check engine control unit

893403 Engine uppercarr. Engine brake Rule deviation negative A750.X2:11 E 1


Engine brake flap is not actuated
Check cable harness / plug / engine brake flap / engine control unit

893404 Engine uppercarr. Engine brake Rule deviation positive A750.X2:11 E 1


Engine brake flap is not actuated
Check cable harness / plug / engine brake flap / engine control unit

893405 Engine uppercarr. Engine brake Logic threshold breach in shut off condition A750.X2:11 E 1
Engine brake flap is not actuated
Check cable harness / plug / engine brake flap / engine control unit

893406 Engine uppercarr. Engine brake Logic threshold breach (Current less than perm. minimum value) A750.X2:11 E 1
Engine brake flap is not actuated
Check cable harness / plug / engine brake flap / engine control unit

893407 Engine uppercarr. Engine brake Logic threshold breach (Current more than perm. maximum value) A750.X2:11 E 1
Engine brake flap is not actuated
Check cable harness / plug / engine brake flap / engine control unit

893500 Engine uppercarr. Heater flange unit 1 Short circuit after ground or broken wire A750.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

893501 Engine uppercarr. Heater flange unit 1 short circuit to supply voltage A750.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

070645 363
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

893502 Engine uppercarr. Heater flange unit 1 Hardware error (Transistor defective) A750.X2:39/64 E 0
Failure of pre- and afterheat phase
Check engine control unit

893503 Engine uppercarr. Heater flange unit 1 Rule deviation negative A750.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

893504 Engine uppercarr. Heater flange unit 1 Rule deviation positive A750.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

893505 Engine uppercarr. Heater flange unit 1 Logic threshold breach in shut off condition A750.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

893506 Engine uppercarr. Heater flange unit 1 Logic threshold breach (Current less than perm. minimum value) A750.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

893507 Engine uppercarr. Heater flange unit 1 Logic threshold breach (Current more than perm. maximum value) A750.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

893511 Engine uppercarr. Heater flange unit 1 No voltage on heater element A750.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

893512 Engine uppercarr. Heater flange unit 1 Voltage on heater element A750.X2:39/64 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

893600 Engine uppercarr. Heater flange unit 2 Short circuit after ground or broken wire A750.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

893601 Engine uppercarr. Heater flange unit 2 short circuit to supply voltage A750.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

070645 364
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

893602 Engine uppercarr. Heater flange unit 2 Hardware error (Transistor defective) A750.X2:25/65 E 0
Failure of pre- and afterheat phase
Check engine control unit

893603 Engine uppercarr. Heater flange unit 2 Rule deviation negative A750.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

893604 Engine uppercarr. Heater flange unit 2 Rule deviation positive A750.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

893605 Engine uppercarr. Heater flange unit 2 Logic threshold breach in shut off condition A750.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

893606 Engine uppercarr. Heater flange unit 2 Logic threshold breach (Current less than perm. minimum value) A750.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

893607 Engine uppercarr. Heater flange unit 2 Logic threshold breach (Current more than perm. maximum value) A750.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

893611 Engine uppercarr. Heater flange unit 2 No voltage on heater element A750.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

893612 Engine uppercarr. Heater flange unit 2 Voltage on heater element A750.X2:25/65 E 0
Failure of pre- and afterheat phase
Check wiring harness / plug / heater flange or glow plug unit/ ext. relay / engine control unit

893700 Engine uppercarr. Solenoid valves Short circuit after ground or broken wire A750.X2:25/65 E 0
Failure of after heat phase
Check cable harness / plug / solenoid valve flame start system/ engine control unit

893701 Engine uppercarr. Solenoid valves short circuit to supply voltage A750.X2:25/65 E 0
Failure of after heat phase
Check cable harness / plug / solenoid valve flame start system/ engine control unit

070645 365
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

893702 Engine uppercarr. Solenoid valves Hardware error (Transistor defective) A750.X2:25/65 E 0
Failure of after heat phase
Check engine control unit

893703 Engine uppercarr. Solenoid valves Rule deviation negative A750.X2:25/65 E 0


Failure of after heat phase
Check cable harness / plug / solenoid valve flame start system/ engine control unit

893704 Engine uppercarr. Solenoid valves Rule deviation positive A750.X2:25/65 E 0


Failure of after heat phase
Check cable harness / plug / solenoid valve flame start system/ engine control unit

893705 Engine uppercarr. Solenoid valves Logic threshold breach in shut off condition A750.X2:25/65 E 0
Failure of after heat phase
Check cable harness / plug / solenoid valve flame start system/ engine control unit

893706 Engine uppercarr. Solenoid valves Logic threshold breach (Current less than perm. minimum value) A750.X2:25/65 E 0
Failure of after heat phase
Check cable harness / plug / solenoid valve flame start system/ engine control unit

893707 Engine uppercarr. Solenoid valves Logic threshold breach (Current more than perm. maximum value) A750.X2:25/65 E 0
Failure of after heat phase
Check cable harness / plug / solenoid valve flame start system/ engine control unit

893800 Engine uppercarr. Turbo charger Short circuit after ground or broken wire A750 E 0
Still to be defined
Check cable harness / plug / solenoid valve Turbo charger / engine control unit

893801 Engine uppercarr. Turbo charger short circuit to supply voltage A750 E 0
Still to be defined
Check cable harness / plug / solenoid valve Turbo charger / engine control unit

893802 Engine uppercarr. Turbo charger Hardware error (Transistor defective) A750 E 0
Still to be defined
Check engine control unit

893803 Engine uppercarr. Turbo charger Rule deviation negative A750 E 0


Still to be defined
Check cable harness / plug / solenoid valve Turbo charger / engine control unit

070645 366
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

893804 Engine uppercarr. Turbo charger Rule deviation positive A750 E 0


Still to be defined
Check cable harness / plug / solenoid valve Turbo charger / engine control unit

893805 Engine uppercarr. Turbo charger Logic threshold breach in shut off condition A750 E 0
Still to be defined
Check cable harness / plug / solenoid valve Turbo charger / engine control unit

893806 Engine uppercarr. Turbo charger Logic threshold breach (Current less than perm. minimum value) A750 E 0
Still to be defined
Check cable harness / plug / solenoid valve Turbo charger / engine control unit

893807 Engine uppercarr. Turbo charger Logic threshold breach (Current more than perm. maximum value) A750 E 0
Still to be defined
Check cable harness / plug / solenoid valve Turbo charger / engine control unit

893900 Engine uppercarr. Exhaust return (AGR) Short circuit after ground or broken wire A750.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit

893901 Engine uppercarr. Exhaust return (AGR) short circuit to supply voltage A750.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit

893902 Engine uppercarr. Exhaust return (AGR) Hardware error (Transistor defective) A750.X1: E 1
External AGR is not actuated
Check engine control unit

893903 Engine uppercarr. Exhaust return (AGR) Rule deviation negative A750.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit

893904 Engine uppercarr. Exhaust return (AGR) Rule deviation positive A750.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit

893905 Engine uppercarr. Exhaust return (AGR) Logic threshold breach (Current higher than perm. min. value) A750.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit

070645 367
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

893906 Engine uppercarr. Exhaust return (AGR) Logic threshold breach (Current less than perm. minimum value) A750.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit

893907 Engine uppercarr. Exhaust return (AGR) Logic threshold breach (Current more than perm. maximum value) A750.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit

893911 Engine uppercarr. Exhaust return (AGR) open without actuation A750.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit

893912 Engine uppercarr. Exhaust return (AGR) closed despite actuation A750.X1: E 1
External AGR is not actuated
Check cable harness / plug / AGR-valve / engine control unit

894000 Engine uppercarr. Emerg. Op. indicator Short circuit after ground or broken wire A750.X2:42 E 1
None
Check cable harness / plug / warn. light / engine control unit

894001 Engine uppercarr. Emerg. Op. indicator short circuit to supply voltage A750.X2:42 E 1
None
Check cable harness / plug / warn. light / engine control unit

894002 Engine uppercarr. Emerg. Op. indicator Hardware error (Transistor defective) A750.X2:42 E 1
None
Check engine control unit

894100 Engine uppercarr. Indicator light preglow / start readiness Short circuit after ground or broken wire A750.X2:28 E 1
None
Check cable harness / plug / warn. light / engine control unit

894101 Engine uppercarr. Indicator light preglow / start readiness short circuit to supply voltage A750.X2:28 E 1
None
Check cable harness / plug / warn. light / engine control unit

894102 Engine uppercarr. Indicator light preglow / start readiness Hardware error (Transistor defective) A750.X2:28 E 1
None
Check engine control unit

070645 368
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

894200 Engine uppercarr. Charge indicator Alternator Short circuit after ground or broken wire A750.X2:14 E 1
None
Check cable harness / plug / warn. light / engine control unit

894201 Engine uppercarr. Charge indicator Alternator short circuit to supply voltage A750.X2:14 E 1
None
Check cable harness / plug / warn. light / engine control unit

894202 Engine uppercarr. Charge indicator Alternator Hardware error (Transistor defective) A750.X2:14 E 1
None
Check engine control unit

894900 Engine uppercarr. RPM signal output Short circuit after ground or broken wire A750 E 1
None
Check cable harness / plug / connected. module

894901 Engine uppercarr. RPM signal output short circuit to supply voltage A750 E 1
None
Check cable harness / plug / connected. module

895000 Engine uppercarr. Cylinder A1 Current back test erroneous or broken wire A750.X1:22/8 E 0
No
Check cable / plug / solenoid valve / engine control unit

895001 Engine uppercarr. Cylinder A1 UeberCurrent LowSide (ground switch ) A750.X1:22/8 E 0


No
Check cable / plug / solenoid valve / engine control unit

895002 Engine uppercarr. Cylinder A1 UeberCurrent HighSide (Plus switch ) A750.X1:22/8 E 0


No
Check cable / plug / solenoid valve / engine control unit

895003 Engine uppercarr. Cylinder A1 Overcurent HighSide (free wheel) A750.X1:22/8 E 0


No
Check cable / plug / solenoid valve / engine control unit

895004 Engine uppercarr. Cylinder A1 No fly time measured A750.X1:22/8 E 0


No
Replace engine control unit

070645 369
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

895005 Engine uppercarr. Cylinder A1 Fly time too small A750.X1:22/8 E 0


No
Check cable / plug / solenoid valve / engine control unit

895006 Engine uppercarr. Cylinder A1 Fly time too large A750.X1:22/8 E 0


No
Check cable / plug / solenoid valve / engine control unit

895007 Engine uppercarr. Cylinder A1 No increase time measured A750.X1:22/8 E 0


No
Replace engine control unit

895008 Engine uppercarr. Cylinder A1 Increase time too large A750.X1:22/8 E 0


No
New data set, or replace engine control unit

895100 Engine uppercarr. Cylinder A2 Current back test erroneous or broken wire A750.X1:21/7 E 0
No
Check cable / plug / solenoid valve / engine control unit

895101 Engine uppercarr. Cylinder A2 UeberCurrent LowSide (ground switch ) A750.X1:21/7 E 0


No
Check cable / plug / solenoid valve / engine control unit

895102 Engine uppercarr. Cylinder A2 UeberCurrent HighSide (Plus switch ) A750.X1:21/7 E 0


No
Check cable / plug / solenoid valve / engine control unit

895103 Engine uppercarr. Cylinder A2 Overcurent HighSide (free wheel) A750.X1:21/7 E 0


No
Check cable / plug / solenoid valve / engine control unit

895104 Engine uppercarr. Cylinder A2 No fly time measured A750.X1:21/7 E 0


No
Replace engine control unit

895105 Engine uppercarr. Cylinder A2 Fly time too small A750.X1:21/7 E 0


No
Check cable / plug / solenoid valve / engine control unit

070645 370
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

895106 Engine uppercarr. Cylinder A2 Fly time too large A750.X1:21/7 E 0


No
Check cable / plug / solenoid valve / engine control unit

895107 Engine uppercarr. Cylinder A2 No increase time measured A750.X1:21/7 E 0


No
Replace engine control unit

895108 Engine uppercarr. Cylinder A2 Increase time too large A750.X1:21/7 E 0


No
New data set, or replace engine control unit

895200 Engine uppercarr. Cylinder A3 Current back test erroneous or broken wire A750.X1:20/6 E 0
No
Check cable / plug / solenoid valve / engine control unit

895201 Engine uppercarr. Cylinder A3 UeberCurrent LowSide (ground switch ) A750.X1:20/6 E 0


No
Check cable / plug / solenoid valve / engine control unit

895202 Engine uppercarr. Cylinder A3 UeberCurrent HighSide (Plus switch ) A750.X1:20/6 E 0


No
Check cable / plug / solenoid valve / engine control unit

895203 Engine uppercarr. Cylinder A3 Overcurent HighSide (free wheel) A750.X1:20/6 E 0


No
Check cable / plug / solenoid valve / engine control unit

895204 Engine uppercarr. Cylinder A3 No fly time measured A750.X1:20/6 E 0


No
Replace engine control unit

895205 Engine uppercarr. Cylinder A3 Fly time too small A750.X1:20/6 E 0


No
Check cable / plug / solenoid valve / engine control unit

895206 Engine uppercarr. Cylinder A3 Fly time too large A750.X1:20/6 E 0


No
Check cable / plug / solenoid valve / engine control unit

070645 371
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

895207 Engine uppercarr. Cylinder A3 No increase time measured A750.X1:20/6 E 0


No
Replace engine control unit

895208 Engine uppercarr. Cylinder A3 Increase time too large A750.X1:20/6 E 0


No
New data set, or replace engine control unit

895300 Engine uppercarr. Cylinder A4 Current back test erroneous or broken wire A750.X1:19/5 E 0
No
Check cable / plug / solenoid valve / engine control unit

895301 Engine uppercarr. Cylinder A4 UeberCurrent LowSide (ground switch ) A750.X1:19/5 E 0


No
Check cable / plug / solenoid valve / engine control unit

895302 Engine uppercarr. Cylinder A4 UeberCurrent HighSide (Plus switch ) A750.X1:19/5 E 0


No
Check cable / plug / solenoid valve / engine control unit

895303 Engine uppercarr. Cylinder A4 Overcurent HighSide (free wheel) A750.X1:19/5 E 0


No
Check cable / plug / solenoid valve / engine control unit

895304 Engine uppercarr. Cylinder A4 No fly time measured A750.X1:19/5 E 0


No
Replace engine control unit

895305 Engine uppercarr. Cylinder A4 Fly time too small A750.X1:19/5 E 0


No
Check cable / plug / solenoid valve / engine control unit

895306 Engine uppercarr. Cylinder A4 Fly time too large A750.X1:19/5 E 0


No
Check cable / plug / solenoid valve / engine control unit

895307 Engine uppercarr. Cylinder A4 No increase time measured A750.X1:19/5 E 0


No
Replace engine control unit

070645 372
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

895308 Engine uppercarr. Cylinder A4 Increase time too large A750.X1:19/5 E 0


No
New data set, or replace engine control unit

895800 Engine uppercarr. Cylinder B1 Current back test erroneous or broken wire A750.X1:18/4 E 0
No
Check cable / plug / solenoid valve / engine control unit

895801 Engine uppercarr. Cylinder B1 UeberCurrent LowSide (ground switch ) A750.X1:18/4 E 0


No
Check cable / plug / solenoid valve / engine control unit

895802 Engine uppercarr. Cylinder B1 UeberCurrent HighSide (Plus switch ) A750.X1:18/4 E 0


No
Check cable / plug / solenoid valve / engine control unit

895803 Engine uppercarr. Cylinder B1 Overcurent HighSide (free wheel) A750.X1:18/4 E 0


No
Check cable / plug / solenoid valve / engine control unit

895804 Engine uppercarr. Cylinder B1 No fly time measured A750.X1:18/4 E 0


No
Replace engine control unit

895805 Engine uppercarr. Cylinder B1 Fly time too small A750.X1:18/4 E 0


No
Check cable / plug / solenoid valve / engine control unit

895806 Engine uppercarr. Cylinder B1 Fly time too large A750.X1:18/4 E 0


No
Check cable / plug / solenoid valve / engine control unit

895807 Engine uppercarr. Cylinder B1 No increase time measured A750.X1:18/4 E 0


No
Replace engine control unit

895808 Engine uppercarr. Cylinder B1 Increase time too large A750.X1:18/4 E 0


No
New data set, or replace engine control unit

070645 373
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

895900 Engine uppercarr. Cylinder B2 Current back test erroneous or broken wire A750.X1:17/3 E 0
No
Check cable / plug / solenoid valve / engine control unit

895901 Engine uppercarr. Cylinder B2 UeberCurrent LowSide (ground switch ) A750.X1:17/3 E 0


No
Check cable / plug / solenoid valve / engine control unit

895902 Engine uppercarr. Cylinder B2 UeberCurrent HighSide (Plus switch ) A750.X1:17/3 E 0


No
Check cable / plug / solenoid valve / engine control unit

895903 Engine uppercarr. Cylinder B2 Overcurent HighSide (free wheel) A750.X1:17/3 E 0


No
Check cable / plug / solenoid valve / engine control unit

895904 Engine uppercarr. Cylinder B2 No fly time measured A750.X1:17/3 E 0


No
Replace engine control unit

895905 Engine uppercarr. Cylinder B2 Fly time too small A750.X1:17/3 E 0


No
Check cable / plug / solenoid valve / engine control unit

895906 Engine uppercarr. Cylinder B2 Fly time too large A750.X1:17/3 E 0


No
Check cable / plug / solenoid valve / engine control unit

895907 Engine uppercarr. Cylinder B2 No increase time measured A750.X1:17/3 E 0


No
Replace engine control unit

895908 Engine uppercarr. Cylinder B2 Increase time too large A750.X1:17/3 E 0


No
New data set, or replace engine control unit

896000 Engine uppercarr. Cylinder B3 Current back test erroneous or broken wire A750.X1:16/2 E 0
No
Check cable / plug / solenoid valve / engine control unit

070645 374
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

896001 Engine uppercarr. Cylinder B3 UeberCurrent LowSide (ground switch ) A750.X1:16/2 E 0


No
Check cable / plug / solenoid valve / engine control unit

896002 Engine uppercarr. Cylinder B3 UeberCurrent HighSide (Plus switch ) A750.X1:16/2 E 0


No
Check cable / plug / solenoid valve / engine control unit

896003 Engine uppercarr. Cylinder B3 Overcurent HighSide (free wheel) A750.X1:16/2 E 0


No
Check cable / plug / solenoid valve / engine control unit

896004 Engine uppercarr. Cylinder B3 No fly time measured A750.X1:16/2 E 0


No
Replace engine control unit

896005 Engine uppercarr. Cylinder B3 Fly time too small A750.X1:16/2 E 0


No
Check cable / plug / solenoid valve / engine control unit

896006 Engine uppercarr. Cylinder B3 Fly time too large A750.X1:16/2 E 0


No
Check cable / plug / solenoid valve / engine control unit

896007 Engine uppercarr. Cylinder B3 No increase time measured A750.X1:16/2 E 0


No
Replace engine control unit

896008 Engine uppercarr. Cylinder B3 Increase time too large A750.X1:16/2 E 0


No
New data set, or replace engine control unit

896100 Engine uppercarr. Cylinder B4 Current back test erroneous or broken wire A750.X1:15/1 E 0
No
Check cable / plug / solenoid valve / engine control unit

896101 Engine uppercarr. Cylinder B4 UeberCurrent LowSide (ground switch ) A750.X1:15/1 E 0


No
Check cable / plug / solenoid valve / engine control unit

070645 375
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

896102 Engine uppercarr. Cylinder B4 UeberCurrent HighSide (Plus switch ) A750.X1:15/1 E 0


No
Check cable / plug / solenoid valve / engine control unit

896103 Engine uppercarr. Cylinder B4 Overcurent HighSide (free wheel) A750.X1:15/1 E 0


No
Check cable / plug / solenoid valve / engine control unit

896104 Engine uppercarr. Cylinder B4 No fly time measured A750.X1:15/1 E 0


No
Replace engine control unit

896105 Engine uppercarr. Cylinder B4 Fly time too small A750.X1:15/1 E 0


No
Check cable / plug / solenoid valve / engine control unit

896106 Engine uppercarr. Cylinder B4 Fly time too large A750.X1:15/1 E 0


No
Check cable / plug / solenoid valve / engine control unit

896107 Engine uppercarr. Cylinder B4 No increase time measured A750.X1:15/1 E 0


No
Replace engine control unit

896108 Engine uppercarr. Cylinder B4 Increase time too large A750.X1:15/1 E 0


No
New data set, or replace engine control unit

896900 Engine uppercarr. Injection system Cylinder error A750 E 2


Engine shut off, if more than permitted solenoid valve number defective, otherwise load reduction
Check cable / plug / solenoid valve / engine control unit

896901 Engine uppercarr. Injection system Overlap of injection on bank A A750 E 2


Engine shut off
Check injection begin and duration; Select later pre-injection start or deactivate pre-injection

896902 Engine uppercarr. Injection system Overlap of injection on bank B A750 E 2


Engine shut off
Check injection begin and duration; Select later pre-injection start or deactivate pre-injection

070645 376
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

896903 Engine uppercarr. Injection system Short circuit Plus switch after ground on bank A A750 E 1
No
Check cable / plug / solenoid valve / engine control unit

896904 Engine uppercarr. Injection system Short circuit Plus switch after ground on bank B A750 E 1
No
Check cable / plug / solenoid valve / engine control unit

896905 Engine uppercarr. Injection system Short circuit Plus switch after supply voltage on bank A A750 E 1
No
Check cable / plug / solenoid valve / engine control unit

896906 Engine uppercarr. Injection system Short circuit Plus switch after supply voltage on bank B A750 E 1
No
Check cable / plug / solenoid valve / engine control unit

896907 Engine uppercarr. Injection system Short circuit Ground switch after ground on bank A A750 E 1
at CR-Motor occurs shut off of bank A
Check cable / plug / solenoid valve / engine control unit

896908 Engine uppercarr. Injection system Short circuit Ground switch after ground on bank B A750 E 1
at CR-Motor occurs shut off of bank B
Check cable / plug / solenoid valve / engine control unit

896909 Engine uppercarr. Injection system Short circuit Ground switch after supply voltage on bank A A750 E 1
No
Check cable / plug / solenoid valve / engine control unit

896910 Engine uppercarr. Injection system Short circuit Ground switch after supply voltage on bank B A750 E 1
No
Check cable / plug / solenoid valve / engine control unit

897000 Engine uppercarr. Overspeed RPM sensor 1 Warning threshold exceeded A750 E 1
None
Check engine op. (excess. speed due to push op.); engine control unit

897001 Engine uppercarr. Overspeed RPM sensor 2 Warning threshold exceeded A750 E 1
None
Check engine op. (excess. speed due to push op.); engine control unit

070645 377
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

897002 Engine uppercarr. Overspeed RPM sensor 1 Safety threshold exceeded A750 E 2
Engine shut off
Check engine op. (excess. speed due to push op.); engine control unit

897003 Engine uppercarr. Overspeed RPM sensor 2 Safety threshold exceeded A750 E 2
Engine shut off
Check engine op. (excess. speed due to push op.); engine control unit

897100 Engine uppercarr. Synchronization defective A750 E 1


Engine start not possible
Turn ign. on / off; check RPM and phase sensor

897101 Engine uppercarr. Synchronization incorrect distance gap<>Phase sensor A750 E 1


Engine start not possible
Turn ign. on / off; check RPM and phase sensor

897102 Engine uppercarr. Synchronization Tooth number not correct A750 E 1


Engine start not possible
Turn ign. on / off; check RPM sensor

897103 Engine uppercarr. Synchronization not possible, RPM is too low A750 E 1
Engine start not possible
Turn ign. on / off; check RPM and phase sensor

897104 Engine uppercarr. Synchronization Index counter camshaft gear erroneous A750 E 1
Engine start not possible
Turn ign. on / off; check RPM and phase sensor

897200 Engine uppercarr. RPM sensor 1 failed A750.X1:69/55/4 E 1


Em. shut off at simult. failure of redundant sensor (1 or 2). Otherwise RPM deter. via red. sensor 1
Check: distance of RPM sensor to flywheel (0.5-2.0 mm); Wiring to RPM sensor; RPM sensor

897201 Engine uppercarr. RPM sensor 1 does not start A750.X1:69/55/4 E 1


Em. shut off at simult. failure of redundant sensor (1 or 2). Otherwise RPM deter. via red. sensor 1
Check: distance of RPM sensor to flywheel (0.5-2.0 mm); Wiring to RPM sensor; RPM sensor

897202 Engine uppercarr. RPM sensor 1 impermissible signal difference (Gradient breach) A750.X1:69/55/4 E 1
Em. shut off at simult. failure of redundant sensor (1 or 2). Otherwise RPM deter. via red. sensor 1
Check distance of RPM sensor to flywheel (0.5-2.0 mm); flywheel, wiring to RPM sensor

070645 378
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

897203 Engine uppercarr. RPM sensor 1 Frequency too high A750.X1:69/55/4 E 1


Em. shut off at simult. failure of redundant sensor (1 or 2). Otherwise RPM deter. via red. sensor 1
Check distance of RPM sensor to flywheel (0.5-2.0 mm); flywheel, wiring to RPM sensor

897204 Engine uppercarr. RPM sensor 1 poled A750.X1:69/55/4 E 1


Em. shut off at simult. failure of redundant sensor (1 or 2). Otherwise RPM deter. via red. sensor 1
Check RPM sensor inst., engine control unit.

897300 Engine uppercarr. RPM sensor 2 failed A750.X1:68/54/4 E 1


Em. shut off at simult. failure of redundant sensor (1 or 2). Otherwise RPM deter. via red. sensor 0
Check: distance of RPM sensor to flywheel (0.5-2.0 mm); Wiring to RPM sensor; RPM sensor

897301 Engine uppercarr. RPM sensor 2 does not start A750.X1:68/54/4 E 1


Em. shut off at simult. failure of redundant sensor (1 or 2). Otherwise RPM deter. via red. sensor 0
Check: distance of RPM sensor to flywheel (0.5-2.0 mm); Wiring to RPM sensor; RPM sensor

897302 Engine uppercarr. RPM sensor 2 impermissible signal difference (Gradient breach) A750.X1:68/54/4 E 1
Em. shut off at simult. failure of redundant sensor (1 or 2). Otherwise RPM deter. via red. sensor 0
Check distance of RPM sensor to flywheel (0.5-2.0 mm); flywheel, wiring to RPM sensor

897303 Engine uppercarr. RPM sensor 2 Frequency too high A750.X1:68/54/4 E 1


Em. shut off at simult. failure of redundant sensor (1 or 2). Otherwise RPM deter. via red. sensor 0
Check distance of RPM sensor to flywheel (0.5-2.0 mm); flywheel, wiring to RPM sensor

897304 Engine uppercarr. RPM sensor 2 poled A750.X1:68/54/4 E 1


Em. shut off at simult. failure of redundant sensor (1 or 2). Otherwise RPM deter. via red. sensor 0
Check RPM sensor inst., engine control unit.

897400 Engine uppercarr. Sensor Position camshaft failed A750.X1:70/56/4 E 1


Engine start, dep. on configuration, not possible. No effect with engine running 2
Check distance of phase sensor to camshaft gear (0.5-2.0 mm); wiring to phase sensor, phase sensor

897500 Engine uppercarr. Travel pedal channel 1 Short circuit after ground or line interruption A750.X2:33/34/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)

897501 Engine uppercarr. Travel pedal channel 1 short circuit to supply voltage A750.X2:33/34/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

070645 379
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

897502 Engine uppercarr. Travel pedal channel 1 Supply voltage Short circuit after ground A750.X2:33/34/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring engine control unit/Sensor (Short circuit after ground)

897503 Engine uppercarr. Travel pedal channel 1 Supply voltage Short circuit after supply voltage A750.X2:33/34/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

897504 Engine uppercarr. Travel pedal channel 1 Signal outside permissible range (Limit 1) A750.X2:33/34/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 5
Check medium for operating range problem. If nec., remedy mechanical problem

897505 Engine uppercarr. Travel pedal channel 1 Signal outside permissible range (Limit 2) A750.X2:33/34/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 5
Check medium for operating range problem. If nec., remedy mechanical problem

897600 Engine uppercarr. Travel pedal channel 2 Short circuit after ground or line interruption A750.X2:47/48/4 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 9
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)

897601 Engine uppercarr. Travel pedal channel 2 short circuit to supply voltage A750.X2:47/48/4 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 9
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

897602 Engine uppercarr. Travel pedal channel 2 Supply voltage Short circuit after ground A750.X2:47/48/4 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 9
Check wiring engine control unit/Sensor (Short circuit after ground)

897603 Engine uppercarr. Travel pedal channel 2 Supply voltage Short circuit after supply voltage A750.X2:47/48/4 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 9
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

897604 Engine uppercarr. Travel pedal channel 2 Signal outside permissible range (Limit 1) A750.X2:47/48/4 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 9
Check medium for operating range problem. If nec., remedy mechanical problem

897605 Engine uppercarr. Travel pedal channel 2 Signal outside permissible range (Limit 2) A750.X2:47/48/4 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 9
Check medium for operating range problem. If nec., remedy mechanical problem

070645 380
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

897700 Engine uppercarr. Sensor coolant level Short circuit after ground or line interruption A750.X2:19/20/2 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)

897701 Engine uppercarr. Sensor coolant level short circuit to supply voltage A750.X2:19/20/2 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

897702 Engine uppercarr. Sensor coolant level Supply voltage Short circuit after ground A750.X2:19/20/2 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring engine control unit/Sensor (Short circuit after ground)

897703 Engine uppercarr. Sensor coolant level Supply voltage Short circuit after supply voltage A750.X2:19/20/2 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

897704 Engine uppercarr. Sensor coolant level Signal outside permissible range (Limit 1) A750.X2:19/20/2 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 1
Check medium for operating range problem. If nec., remedy mechanical problem

897705 Engine uppercarr. Sensor coolant level Signal outside permissible range (Limit 2) A750.X2:19/20/2 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 1
Check medium for operating range problem. If nec., remedy mechanical problem

897800 Engine uppercarr. Sensor oil level Short circuit after ground or line interruption A750 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)

897801 Engine uppercarr. Sensor oil level short circuit to supply voltage A750 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

897802 Engine uppercarr. Sensor oil level Supply voltage Short circuit after ground A750 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

897803 Engine uppercarr. Sensor oil level Supply voltage Short circuit after supply voltage A750 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

070645 381
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

897804 Engine uppercarr. Sensor oil level Signal outside permissible range (Limit 1) A750 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

897805 Engine uppercarr. Sensor oil level Signal outside permissible range (Limit 2) A750 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

898400 Engine uppercarr. Sensor charge air pr, Short circuit after ground or line interruption A750.X1:61/47/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 3
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)

898401 Engine uppercarr. Sensor charge air pr, short circuit to supply voltage A750.X1:61/47/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 3
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

898402 Engine uppercarr. Sensor charge air pr, Supply voltage Short circuit after ground A750.X1:61/47/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 3
Check wiring engine control unit/Sensor (Short circuit after ground)

898403 Engine uppercarr. Sensor charge air pr, Supply voltage Short circuit after supply voltage A750.X1:61/47/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 3
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

898404 Engine uppercarr. Sensor charge air pr, Signal outside permissible range (Limit 1) A750.X1:61/47/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 3
Check medium for operating range problem. If nec., remedy mechanical problem

898405 Engine uppercarr. Sensor charge air pr, Signal outside permissible range (Limit 2) A750.X1:61/47/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 3
Check medium for operating range problem. If nec., remedy mechanical problem

898500 Engine uppercarr. Sensor oil pr. Short circuit after ground or line interruption A750.X1:63/49/3 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)

898501 Engine uppercarr. Sensor oil pr. short circuit to supply voltage A750.X1:63/49/3 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

070645 382
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

898502 Engine uppercarr. Sensor oil pr. Supply voltage Short circuit after ground A750.X1:63/49/3 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring engine control unit/Sensor (Short circuit after ground)

898503 Engine uppercarr. Sensor oil pr. Supply voltage Short circuit after supply voltage A750.X1:63/49/3 E 2
Sensor default value is used. Error disappears, if test values are again in defined range 5
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

898504 Engine uppercarr. Sensor oil pr. Signal outside permissible range (Limit 1) A750.X1:63/49/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 5
Check medium for operating range problem. If nec., remedy mechanical problem

898505 Engine uppercarr. Sensor oil pr. Signal outside permissible range (Limit 2) A750.X1:63/49/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 5
Check medium for operating range problem. If nec., remedy mechanical problem

898600 Engine uppercarr. Sensor fuel pr. Short circuit after ground or line interruption A750.X1:62/48/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 4
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)

898601 Engine uppercarr. Sensor fuel pr. short circuit to supply voltage A750.X1:62/48/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 4
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

898602 Engine uppercarr. Sensor fuel pr. Supply voltage Short circuit after ground A750.X1:62/48/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 4
Check wiring engine control unit/Sensor (Short circuit after ground)

898603 Engine uppercarr. Sensor fuel pr. Supply voltage Short circuit after supply voltage A750.X1:62/48/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 4
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

898604 Engine uppercarr. Sensor fuel pr. Signal outside permissible range (Limit 1) A750.X1:62/48/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 4
Check medium for operating range problem. If nec., remedy mechanical problem

898605 Engine uppercarr. Sensor fuel pr. Signal outside permissible range (Limit 2) A750.X1:62/48/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 4
Check medium for operating range problem. If nec., remedy mechanical problem

070645 383
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

898700 Engine uppercarr. Sensor Air filter contamination Short circuit after ground or line interruption A750.X2:5/6/7 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)

898701 Engine uppercarr. Sensor Air filter contamination short circuit to supply voltage A750.X2:5/6/7 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

898702 Engine uppercarr. Sensor Air filter contamination Supply voltage Short circuit after ground A750.X2:5/6/7 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

898703 Engine uppercarr. Sensor Air filter contamination Supply voltage Short circuit after supply voltage A750.X2:5/6/7 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

898704 Engine uppercarr. Sensor Air filter contamination Signal outside permissible range (Limit 1) A750.X2:5/6/7 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

898705 Engine uppercarr. Sensor Air filter contamination Signal outside permissible range (Limit 2) A750.X2:5/6/7 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

898800 Engine uppercarr. Common Rail Pr. sensor 1 Short circuit after ground or line interruption A750.X1:60/46/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 2
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)

898801 Engine uppercarr. Common Rail Pr. sensor 1 short circuit to supply voltage A750.X1:60/46/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 2
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

898802 Engine uppercarr. Common Rail Pr. sensor 1 Supply voltage Short circuit after ground A750.X1:60/46/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 2
Check wiring engine control unit/Sensor (Short circuit after ground)

898803 Engine uppercarr. Common Rail Pr. sensor 1 Supply voltage Short circuit after supply voltage A750.X1:60/46/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 2
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

070645 384
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

898804 Engine uppercarr. Common Rail Pr. sensor 1 Signal outside permissible range (Limit 1) A750.X1:60/46/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 2
Check medium for operating range problem. If nec., remedy mechanical problem

898805 Engine uppercarr. Common Rail Pr. sensor 1 Signal outside permissible range (Limit 2) A750.X1:60/46/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 2
Check medium for operating range problem. If nec., remedy mechanical problem

898900 Engine uppercarr. Common Rail Pr. sensor 2 Short circuit after ground or line interruption A750.X1:59/45/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)

898901 Engine uppercarr. Common Rail Pr. sensor 2 short circuit to supply voltage A750.X1:59/45/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

898902 Engine uppercarr. Common Rail Pr. sensor 2 Supply voltage Short circuit after ground A750.X1:59/45/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring engine control unit/Sensor (Short circuit after ground)

898903 Engine uppercarr. Common Rail Pr. sensor 2 Supply voltage Short circuit after supply voltage A750.X1:59/45/3 E 1
Sensor default value is used. Error disappears, if test values are again in defined range 1
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

898904 Engine uppercarr. Common Rail Pr. sensor 2 Signal outside permissible range (Limit 1) A750.X1:59/45/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 1
Check medium for operating range problem. If nec., remedy mechanical problem

898905 Engine uppercarr. Common Rail Pr. sensor 2 Signal outside permissible range (Limit 2) A750.X1:59/45/3 E 0
Dep. on configuration, engine shut off, power reduction or no reaction 1
Check medium for operating range problem. If nec., remedy mechanical problem

899000 Engine uppercarr. Sensor ambient pr. Short circuit after ground or line interruption A750 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground or broken cable)

899001 Engine uppercarr. Sensor ambient pr. short circuit to supply voltage A750 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

070645 385
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

899002 Engine uppercarr. Sensor ambient pr. Supply voltage Short circuit after ground A750 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

899003 Engine uppercarr. Sensor ambient pr. Supply voltage Short circuit after supply voltage A750 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

899300 Engine uppercarr. Sensor Water in fuel short circuit to ground A750.X2: E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

899301 Engine uppercarr. Sensor Water in fuel short circuit to supply voltage A750.X2: E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)

899302 Engine uppercarr. Sensor Water in fuel Supply voltage Short circuit after ground A750.X2: E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

899303 Engine uppercarr. Sensor Water in fuel Supply voltage Short circuit after supply voltage A750.X2: E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

899304 Engine uppercarr. Sensor Water in fuel Signal outside permissible range (Limit 1) A750.X2: E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

899305 Engine uppercarr. Sensor Water in fuel Signal outside permissible range (Limit 2) A750.X2: E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

899400 Engine uppercarr. Sensor Intercooler-Temperature short circuit to ground A750.X2: E 1


Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

899401 Engine uppercarr. Sensor Intercooler-Temperature short circuit to supply voltage A750.X2: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)

070645 386
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

899402 Engine uppercarr. Sensor Intercooler-Temperature Supply voltage Short circuit after ground A750.X2: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

899403 Engine uppercarr. Sensor Intercooler-Temperature Supply voltage Short circuit after supply voltage A750.X2: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

899404 Engine uppercarr. Sensor Intercooler-Temperature Signal outside permissible range (Limit 1) A750.X2: E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

899405 Engine uppercarr. Sensor Intercooler-Temperature Signal outside permissible range (Limit 2) A750.X2: E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

899500 Engine uppercarr. Oil temperature sensor short circuit to ground A750.X2:46/60 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

899501 Engine uppercarr. Oil temperature sensor short circuit to supply voltage A750.X2:46/60 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)

899502 Engine uppercarr. Oil temperature sensor Supply voltage Short circuit after ground A750.X2:46/60 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

899503 Engine uppercarr. Oil temperature sensor Supply voltage Short circuit after supply voltage A750.X2:46/60 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

899504 Engine uppercarr. Oil temperature sensor Signal outside permissible range (Limit 1) A750.X2:46/60 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

899505 Engine uppercarr. Oil temperature sensor Signal outside permissible range (Limit 2) A750.X2:46/60 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

070645 387
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

899600 Engine uppercarr. Sensor fuel temperature short circuit to ground A750.X1:38/52 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

899601 Engine uppercarr. Sensor fuel temperature short circuit to supply voltage A750.X1:38/52 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)

899602 Engine uppercarr. Sensor fuel temperature Supply voltage Short circuit after ground A750.X1:38/52 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

899603 Engine uppercarr. Sensor fuel temperature Supply voltage Short circuit after supply voltage A750.X1:38/52 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

899604 Engine uppercarr. Sensor fuel temperature Signal outside permissible range (Limit 1) A750.X1:38/52 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

899605 Engine uppercarr. Sensor fuel temperature Signal outside permissible range (Limit 2) A750.X1:38/52 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

899700 Engine uppercarr. Sensor charge air temperature short circuit to ground A750.X1: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

899701 Engine uppercarr. Sensor charge air temperature short circuit to supply voltage A750.X1: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)

899702 Engine uppercarr. Sensor charge air temperature Supply voltage Short circuit after ground A750.X1: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

899703 Engine uppercarr. Sensor charge air temperature Supply voltage Short circuit after supply voltage A750.X1: E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

070645 388
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

899704 Engine uppercarr. Sensor charge air temperature Signal outside permissible range (Limit 1) A750.X1: E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

899705 Engine uppercarr. Sensor charge air temperature Signal outside permissible range (Limit 2) A750.X1: E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

899800 Engine uppercarr. Sensor coolant temperature short circuit to ground A750.X1:51/37 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

899801 Engine uppercarr. Sensor coolant temperature short circuit to supply voltage A750.X1:51/37 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)

899802 Engine uppercarr. Sensor coolant temperature Supply voltage Short circuit after ground A750.X1:51/37 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

899803 Engine uppercarr. Sensor coolant temperature Supply voltage Short circuit after supply voltage A750.X1:51/37 E 2
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

899804 Engine uppercarr. Sensor coolant temperature Signal outside permissible range (Limit 1) A750.X1:51/37 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

899805 Engine uppercarr. Sensor coolant temperature Signal outside permissible range (Limit 2) A750.X1:51/37 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

899900 Engine uppercarr. Sensor internal temperature short circuit to ground A750 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

899901 Engine uppercarr. Sensor internal temperature short circuit to supply voltage A750 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit / sensor (short circuit after battery voltage or broken wire)

070645 389
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

899902 Engine uppercarr. Sensor internal temperature Supply voltage Short circuit after ground A750 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring engine control unit/Sensor (Short circuit after ground)

899903 Engine uppercarr. Sensor internal temperature Supply voltage Short circuit after supply voltage A750 E 1
Sensor default value is used. Error disappears, if test values are again in defined range
Check wiring of engine control unit/Sensor (Short circuit after battery voltage)

899904 Engine uppercarr. Sensor internal temperature Signal outside permissible range (Limit 1) A750 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

899905 Engine uppercarr. Sensor internal temperature Signal outside permissible range (Limit 2) A750 E 0
Dep. on configuration, engine shut off, power reduction or no reaction
Check medium for operating range problem. If nec., remedy mechanical problem

930106 engine V8: control device engine Data communication CAN faulty / interrupted X275:1/4/7 E 1
emergency operation
check cable/plugs for shorts

930107 engine V8: control device engine Data communication CAN cancelled X275:1/4/7 E 1
emergency operation
check cable/plugs for UB- or shorts to ground

930208 engine V8: CAN-participant ABV (ABS/ASR) Data transfer faulty/missing, max. cycle time exceeded X275:1/4/7 E 1
limited function
check cable/plugs/ABS-/ASR-electronics

930308 engine V8: CAN-participant gear Data transfer faulty/missing, max. cycle time exceeded X275:1/4/7 E 1
limited function
check cable/plugs/gear electronics

930408 engine V8: CAN-participant E/A-Modul Data transfer faulty/missing, max. cycle time exceeded X275:1/4/7 E 1
emergency operation
check cable/plugs/E/A-Modul(e)

930508 engine V8: CAN signals gear Data transfer faulty/missing, max. cycle time exceeded X275:1/4/7 E 1
limited function
check cable/plugs/gear electronics

070645 390
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

930608 engine V8: CAN signals travel switch Data transfer faulty/missing, max. cycle time exceeded X275:1/4/7 E 1
limited function
check cable/plugs/E/A-Modul(e)

930709 engine V8: speed sensor 1 gradient damage X273:19/20 E 1


switch-over to speed 2 or engine-stop with error code 0809
check cable/plugs/sensor, distance to flywheel

930809 engine V8: speed sensor 2 gradient damage X273:18/21 E 1


switch-over to speed 2 or engine-stop with error code 0709
check cable/plugs/sensor, distance to flywheel

930910 engine V8: speed 1/2 inadmissable signal difference/plausability control defective X273:18/19/20/2 E 1
switch-over to other speed sensor or engine-stop 1
check cable/plugs/sensor, distance to flywheel

931002 engine V8: accelerator 1 sensor defect high/short circ. to supply voltage X274:16/17 E 1
switch-over to accelerator 2,speed limitation, torque limitation or 20-23
check cable/plugs for UB-shorts

931003 engine V8: accelerator 1 sensor defect low/short circuit to ground X274:16/17 E 1
switch-over to accelerator 2,speed limitation, torque limitation or 20-23
check cable/plugs for breaks or short to ground

931004 engine V8: accelerator 1 level exceeded X274:16/17 E 1


switch-over to accelerator 2,speed limitation, torque limitation or 20-23
check cable/plugs for UB-shorts, check pedal unit

931005 engine V8: accelerator 1 below minimum level X274:16/17 E 1


switch-over to accelerator 2,speed limitation, torque limitation or 20-23
check cable/plugs for break or short to ground, check pedal unit

931102 engine V8: accelerator 2 sensor defect high/short circ. to supply voltage X274:14/15 E 1
switch-over to accelerator 1, speed limitation, torque limitation or emergency operation at error code 16-19
check cable/plugs for UB-shorts

931103 engine V8: accelerator 2 sensor defect low/short circuit to ground X274:14/15 E 1
switch-over to accelerator 1, speed limitation, torque limitation or emergency operation at error code 16-19
check cable/plugs for breaks or short to ground

070645 391
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

931104 engine V8: accelerator 2 level exceeded X274:14/15 E 1


switch-over to accelerator 1, speed limitation, torque limitation or emergency operation at error code 16-19
check cable/plugs for UB-shorts, check pedal unit

931105 engine V8: accelerator 2 below minimum level X274:14/15 E 1


switch-over to accelerator 1, speed limitation, torque limitation or emergency operation at error code 16-19
check cable/plugs for break or short to ground, check pedal unit

931201 engine V8: accelerator 1/2 unit defect X274:14/15/16/1 E 1


gas reduction or gas withdrawal (idle) 7
test error code 16-23, check pedal unit

931210 engine V8: accelerator 1/2 inadmissable signal difference/plausability control defective X274:14/15/16/1 E 1
gas withdrawal (idle) 7
check pedal unit, check condition of operation brake

931280 engine V8: accelerator 1/2 Actuation with selected/active auxiliary brake X274:14/15/16/1 B
Travel pedal lock 7
Release travel pedal, switch off auxiliary brake

931611 engine V8: trigger signal box EDC excess current recognition X271:7/10 E 1
engine-Stop
check cable/plugs, replace LH-ECU1, check EDC-actuator, if necessary replace injector pump

931701 engine V8: signal box feedback EDC unit defect X271:13/14/15 E 1
engine-Stop
check cable/plugs, replace LH-ECU1, check EDC-actuator, if necessary replace injector pump

931812 engine V8: alternator D+ short circuit to ground X273:14 E 1


warning
check cable/plugs for short to ground

931813 engine V8: alternator D+ open signal circuits X273:14 E 1


signal ignored
check cable/plugs for breaks

931814 engine V8: alternator D+ short circuit to supply voltage X273:14 E 1


signal ignored
check cable/plugs for UB-shorts

070645 392
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

931916 engine V8: supply KL30 excess voltage X272:1 E 1


generate error report; Reset: automatic after error counter sequence or regulator reset
check main circuit voltage, check battery

931917 engine V8: supply KL30 voltage below required value X272:1 E 1
generate error report; Reset: automatic after error counter sequence or regulator reset
check main circuit voltage, check battery

932012 engine V8: start engine KL50 short circuit to ground X274:13 E 1
generate error report; Reset: automatic after error counter sequence or regulator reset
check cable/plugs for short to ground

932112 engine V8: DA, flame type heater plugs diagnosis short circuit to ground X271:9 E 1
error report
check cable/plugs for short to ground, replace Relaismodul

932113 engine V8: DA, flame type heater plugs diagnosis open signal circuits X271:9 E 1
shut off FGK and MVE
check cable/plugs for breaks, replace Relaismodul

932114 engine V8: DA, flame type heater plugs diagnosis short circuit to supply voltage X271:9 E 1
error report
check cable/plugs for UB-shorts, replace Relaismodul

932211 engine V8: Actuator prestroke excess current recognition X271:12/3 E 1


Engine-stop
Check or replace line connection ECU<->EDC-actuator, EDC-actuator, injection pump

932312 engine V8: Control blower short circuit to ground X274:8/9 E 1


Blower turns at full speed following wire break/short-circuit, no blower regulation possible
Line connection ECU<->fan, ECU-output, check fan valve

932315 engine V8: Control blower open electric circuit X274:8/9 E 1


Blower turns at full speed following wire break/short-circuit, no blower regulation possible
Line connection ECU<->fan, ECU-output, check fan valve

932318 engine V8: Control blower excess temperature X274:8/9 E 1


Blower turns at full speed following wire break/short-circuit, no blower regulation possible
Line connection ECU<->fan, ECU-output, check fan valve

070645 393
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

932512 engine V8: Speed signal tachograph short circuit to ground X275:9 E 1
Signal is ignored, switch off of functions TMAT/TSET, reduction of maximum moment due to Vset
Check or replace line connection tachograph<->ECU, tachograph, ECU

932513 engine V8: Speed signal tachograph open signal circuits X275:9 E 1
Signal is ignored, switch off of functions TMAT/TSET, reduction of maximum moment due to Vset
Check or replace line connection tachograph<->ECU, tachograph, ECU

932514 engine V8: Speed signal tachograph short circuit to supply voltage X275:9 E 1
Signal is ignored, switch off of functions TMAT/TSET, reduction of maximum moment due to Vset
Check or replace line connection tachograph<->ECU, tachograph, ECU

932602 engine V8: oil pressure sensor sensor defect high/short circ. to supply voltage X273:1/2/3 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor

932603 engine V8: oil pressure sensor sensor defect low/short circuit to ground X273:1/2/3 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor

932702 engine V8: charge air pressure sensor sensor defect high/short circ. to supply voltage X273:4/5/6 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor

932703 engine V8: charge air pressure sensor sensor defect low/short circuit to ground X273:4/5/6 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor

932802 engine V8: air filter sensor sensor defect high/short circ. to supply voltage X273:7/8/9 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor

932803 engine V8: air filter sensor sensor defect low/short circuit to ground X273:7/8/9 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor

933102 engine V8: charge air temperature sensor sensor defect high/short circ. to supply voltage X273:12/15 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor

070645 394
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

933103 engine V8: charge air temperature sensor sensor defect low/short circuit to ground X273:12/15 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor

933202 engine V8: coolant temperature sensor sensor defect high/short circ. to supply voltage X273:10/11 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor

933203 engine V8: coolant temperature sensor sensor defect low/short circuit to ground X273:10/11 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor

933313 engine V8: coolant level sensor open signal circuits X274:10/11 E 1
signal ignored, substitute value used
check cable/plugs for defects or breaks, replace sensor

933402 engine V8: oil temperature sensor sensor defect high/short circ. to supply voltage X273:16/17 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor

933403 engine V8: oil temperature sensor sensor defect low/short circuit to ground X273:16/17 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor

933512 engine V8: Sensor jib-movement-detector (NBF) short circuit to ground X271:1/2 E 1
Change-over to power-regulated operation
Check line connection ECU<->NBF sensor, NBV sensor; Replace NBF sensor

933513 engine V8: Sensor jib-movement-detector (NBF) open signal circuits X271:1/2 E 1
Change-over to power-regulated operation
Check line connection ECU<->NBF sensor, NBV sensor; Replace NBF sensor

933514 engine V8: Sensor jib-movement-detector (NBF) short circuit to supply voltage X271:1/2 E 1
Change-over to power-regulated operation
Check line connection ECU<->NBF sensor, NBV sensor; Replace NBF sensor

933601 engine V8: trigger flame type heater plug(s) FGK unit defect X271:4 E 1
shut off FGK and MVE
check cable/plugs for defects or breaks, check FGK, replace Relaismodul

070645 395
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

933614 engine V8: trigger flame type heater plug(s) FGK short circuit to supply voltage X271:4 E 1

933615 engine V8: trigger flame type heater plug(s) FGK open electric circuit X271:4 E 1
error report
check cable/plugs for breaks, replace Relaismodul

933618 engine V8: trigger flame type heater plug(s) FGK excess temperature X271:4 E 1
shut off FGK and MVE
check cable/plugs for short to ground, replace Relaismodul

933714 engine V8: solenoid valve additional flow for starting short circuit to supply voltage X271:6 E 1

933715 engine V8: solenoid valve additional flow for starting open electric circuit X271:6 E 1
FSA data defective, FGK activation removed, MVE reset: automatic after error counter sequence, after regulator reset

933718 engine V8: solenoid valve additional flow for starting excess temperature X271:6 E 1
shut off FGK and MVE
check cable/plugs for short to ground, replace Relaismodul

933814 engine V8: engine start 50A short circuit to supply voltage X271:5 E 1

933815 engine V8: engine start 50A open electric circuit X271:5 E 1
starting procedure interrupted, shut down FGK and MVE
check cable/plugs for breaks, replace Relaismodul

933818 engine V8: engine start 50A excess temperature X271:5 E 1


starting procedure interrupted, shut down FGK and MVE
check cable/plugs for short to ground, replace Relaismodul

933908 engine V8: CAN-signals retarder Data transfer faulty/missing, max. cycle time exceeded X27 E 1
limited function
Check cable/plug/RET-electronics/CAN-Bus system

070645 396
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

934008 engine V8: CAN-signals WSK Data transfer faulty/missing, max. cycle time exceeded X27 E 1
limited function
Check cable/plug/WSK-electronics/CAN-Bus system

934118 engine V8: control device ECU excess temperature X271 E 1


error report
allow machine to cool, check installation location, if necessary take further cooling measures

934119 engine V8: control device ECU deviation X271 E 1


engine-Stop
regulator-reset (Kl.15), Check cable/plugs EDC-actuator, EDC-actuator; ECU, replace injector pump

934120 engine V8: control device ECU saving error X271 E 1

replace ECU

934221 engine V8: RAM/FLASH memory invalid data record X271 E 1


engine-Stop
replace ECU

934320 engine V8: EEPROM memory saving error X271 E 1


use of redundant memory (Flash-EPROM)
replace ECU

934321 engine V8: EEPROM memory invalid data record X271 E 1


engine start not possible
replace ECU

934504 engine V8: Calculation spray begin (SB) level exceeded X271 E 1
Change-over to controlled injection-start operation (SB)

934505 engine V8: Calculation spray begin (SB) below minimum level X271 E 1
Change-over to controlled injection-start operation (SB)

934526 engine V8: Calculation spray begin (SB) No synchronisation possible X271 E 1
Change-over to controlled injection-start operation (SB)
Checking of OT signal transmitter and NBF

070645 397
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

936124 engine V8: charge air temperature pre-warning disruption limit 1 X273:12/15 E 1
warning, engine-protection-info, output reduction
reduce output, check air suction routing and engine

936125 engine V8: charge air temperature pre-warning disruption limit 2 X273:12/15 E 1
warning, engine-protection-info, output reduction
reduce output, if necessary shut off engine, check air suction routing and engine

936224 engine V8: coolant temperature pre-warning disruption limit 1 X273:10/11 E 1


warning, engine-protection-info, output reduction
reduce output, check coolant level and engine

936225 engine V8: coolant temperature pre-warning disruption limit 2 X273:10/11 E 1


warning, engine-protection-info, output reduction
reduce output, if necessary shut off engine, check coolant level and engine

936324 engine V8: coolant level pre-warning disruption limit 1 X274:11/12 E 1


warning
shut off engine, check coolant level and if necessary replenish, check for leaks

936424 engine V8: oil pressure pre-warning disruption limit 1 X273:1/2/3 E 1


warning
shut off engine, check oil level and if necessary replenish, check for leaks

936522 engine V8: air filter pressure pre-warning disruption limit 1 X273:7/8/9 E 1
pre-warning
replace air filter at next opportunity

936525 engine V8: air filter pressure pre-warning disruption limit 2 X273:7/8/9 E 1
warning
replace air filter immediately

936624 engine V8: v-belt break pre-warning disruption limit 1 X273:14 E 1


warning
replace V-belts, check generator and replace if necessary

936724 engine V8: speed pre-warning disruption limit 1 X273:18/19/20/2 E 1


warning, engine-protection-info, injector quantities 0, activation of engine brake 1
shut off engine, regulator-reset (Kl.15)

070645 398
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

936824 engine V8: charge air pressure pre-warning disruption limit 1 X273:4/5/6 E 1
signal ignored, substitute value will be used, error report
check air suction routing

936825 engine V8: charge air pressure pre-warning disruption limit 2 X273:4/5/6 E 1
signal ignored, substitute value will be used, error report
check air suction routing

936924 engine V8: oil temperature pre-warning disruption limit 1 X273:16/17 E 1


signal ignored, substitute value will be used, error report
check oil level/oil circulation

936925 engine V8: oil temperature pre-warning disruption limit 2 X273:16/17 E 1


signal ignored, substitute value will be used, error report
check oil level/oil circulation

938150 engine V8: v-belt-control service report interval 1 attained/exceeded X27 E 1


report
check and return

938250 engine V8: change engine oil filter service report interval 1 attained/exceeded X27 E 1
report
check and return

938350 engine V8: change engine oil service report interval 1 attained/exceeded X27 E 1
report
change oil and return

938351 engine V8: change engine oil service report interval 2 attained/exceeded X27 E 1
report
change oil and return

938352 engine V8: change engine oil service report interval 3 attained/exceeded X27 E 1
report
change oil and return

938353 engine V8: change engine oil service report interval 4 attained/exceeded X27 E 1
report
change oil and return

070645 399
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

938354 engine V8: change engine oil service report interval 5 attained/exceeded X27 E 1
report
change oil and return

938355 engine V8: change engine oil service report interval 6 attained/exceeded X27 E 1
report
change oil and return

938356 engine V8: change engine oil service report interval 7 attained/exceeded X27 E 1
report
change oil and return

938357 engine V8: change engine oil service report interval 8 attained/exceeded X27 E 1
report
change oil and return

938358 engine V8: change engine oil service report interval 9 attained/exceeded X27 E 1
report
change oil and return

938359 engine V8: change engine oil service report interval 10 attained/exceeded X27 E 1
report
change oil and return

938650 engine V8: check battery service report interval 1 attained/exceeded X27 E 1
report
check and return

938750 engine V8: change water filter service report interval 1 attained/exceeded X27 E 1
report
change filter and return

938850 engine V8: check antifreeze service report interval 1 attained/exceeded X27 E 1
report
check and return

938950 engine V8: fuel filter level 1 service report interval 1 attained/exceeded X27 E 1
report
change filter and return

070645 400
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

939050 engine V8: fuel filter level 2 service report interval 1 attained/exceeded X27 E 1
report
change filter and return

939150 engine V8: valve clearance service report interval 1 attained/exceeded X27 E 1
report
check and return

939250 engine V8: fuel injection valves service report interval 1 attained/exceeded X27 E 1
report
check and return

939350 engine V8: coolant service report interval 1 attained/exceeded X27 E 1


report
check and return

940106 Engine uppercarr. control device engine Data communication CAN faulty / interrupted X705:1/4/7 E 1
emergency operation
check cable/plugs for shorts

940107 Engine uppercarr. control device engine Data communication CAN cancelled X705:1/4/7 E 1
emergency operation
check cable/plugs for UB- or shorts to ground

940208 Engine uppercarr. CAN-participant ABV (ABS/ASR) Data transfer faulty/missing, max. cycle time exceeded X705:1/4/7 E 1
limited function
check cable/plugs/ABS-/ASR-electronics

940308 Engine uppercarr. CAN-participant gear Data transfer faulty/missing, max. cycle time exceeded X705:1/4/7 E 1
limited function
check cable/plugs/gear electronics

940408 Engine uppercarr. CAN-participant E/A-Modul Data transfer faulty/missing, max. cycle time exceeded X705:1/4/7 E 1
emergency operation
check cable/plugs/E/A-Modul(e)

940709 Engine uppercarr. speed sensor 1 gradient damage X703:19/20 E 1


switch-over to speed 2 or engine-stop with error code 0809
check cable/plugs/sensor, distance to flywheel

070645 401
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

940809 Engine uppercarr. speed sensor 2 gradient damage X703:18/21 E 1


switch-over to speed 2 or engine-stop with error code 0709
check cable/plugs/sensor, distance to flywheel

940910 Engine uppercarr. speed 1/2 inadmissable signal difference/plausability control defective X703:18/19/20/2 E 1
switch-over to other speed sensor or engine-stop 1
check cable/plugs/sensor, distance to flywheel

941002 Engine uppercarr. accelerator 1 sensor defect high/short circ. to supply voltage X704:16/17 E 1
switch-over to accelerator 2,speed limitation, torque limitation or 20-23
check cable/plugs for UB-shorts

941003 Engine uppercarr. accelerator 1 sensor defect low/short circuit to ground X704:16/17 E 1
switch-over to accelerator 2,speed limitation, torque limitation or 20-23
check cable/plugs for breaks or short to ground

941004 Engine uppercarr. accelerator 1 level exceeded X704:16/17 E 1


switch-over to accelerator 2,speed limitation, torque limitation or 20-23
check cable/plugs for UB-shorts, check pedal unit

941005 Engine uppercarr. accelerator 1 below minimum level X704:16/17 E 1


switch-over to accelerator 2,speed limitation, torque limitation or 20-23
check cable/plugs for break or short to ground, check pedal unit

941102 Engine uppercarr. accelerator 2 sensor defect high/short circ. to supply voltage X704:14/15 E 1
switch-over to accelerator 1, speed limitation, torque limitation or emergency operation at error code 16-19
check cable/plugs for UB-shorts

941103 Engine uppercarr. accelerator 2 sensor defect low/short circuit to ground X704:14/15 E 1
switch-over to accelerator 1, speed limitation, torque limitation or emergency operation at error code 16-19
check cable/plugs for breaks or short to ground

941104 Engine uppercarr. accelerator 2 level exceeded X704:14/15 E 1


switch-over to accelerator 1, speed limitation, torque limitation or emergency operation at error code 16-19
check cable/plugs for UB-shorts, check pedal unit

941105 Engine uppercarr. accelerator 2 below minimum level X704:14/15 E 1


switch-over to accelerator 1, speed limitation, torque limitation or emergency operation at error code 16-19
check cable/plugs for break or short to ground, check pedal unit

070645 402
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

941201 Engine uppercarr. accelerator 1/2 unit defect X704:14/15/16/1 E 1


gas reduction or gas withdrawal (idle) 7
test error code 16-23, check pedal unit

941210 Engine uppercarr. accelerator 1/2 inadmissable signal difference/plausability control defective X704:14/15/16/1 E 1
gas withdrawal (idle) 7
check pedal unit, check condition of operation brake

941611 Engine uppercarr. trigger signal box EDC excess current recognition X701:7/10 E 1
engine-Stop
check cable/plugs, replace LH-ECU1, check EDC-actuator, if necessary replace injector pump

941701 Engine uppercarr. signal box feedback EDC unit defect X701:13/14/15 E 1
engine-Stop
check cable/plugs, replace LH-ECU1, check EDC-actuator, if necessary replace injector pump

941812 Engine uppercarr. alternator D+ short circuit to ground X703:14 E 1


warning
check cable/plugs for short to ground

941813 Engine uppercarr. alternator D+ open signal circuits X703:14 E 1


signal ignored
check cable/plugs for breaks

941814 Engine uppercarr. alternator D+ short circuit to supply voltage X703:14 E 1


signal ignored
check cable/plugs for UB-shorts

941906 Engine uppercarr. supply KL30 Data communication CAN faulty / interrupted X702:1 E 1
generate error report Reset: automatic after error counter sequence or after regulator-reset
check main circuit voltage, check battery

941907 Engine uppercarr. supply KL30 Data communication CAN cancelled X702:1 E 1
generate error report; Reset: automatic after error counter sequence or regulator reset
check main circuit voltage, check battery

942012 Engine uppercarr. start engine KL50 short circuit to ground X704:13 E 1
generate error report; Reset: automatic after error counter sequence or regulator reset
check cable/plugs for short to ground

070645 403
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

942112 Engine uppercarr. DA, flame type heater plugs diagnosis short circuit to ground X701:9 E 1
error report
check cable/plugs for short to ground, replace Relaismodul

942113 Engine uppercarr. DA, flame type heater plugs diagnosis open signal circuits X701:9 E 1
shut off FGK and MVE
check cable/plugs for breaks, replace Relaismodul

942114 Engine uppercarr. DA, flame type heater plugs diagnosis short circuit to supply voltage X701:9 E 1
error report
check cable/plugs for UB-shorts, replace Relaismodul

942602 Engine uppercarr. oil pressure sensor sensor defect high/short circ. to supply voltage X703:1/2/3 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor

942603 Engine uppercarr. oil pressure sensor sensor defect low/short circuit to ground X703:1/2/3 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor

942702 Engine uppercarr. charge air pressure sensor sensor defect high/short circ. to supply voltage X703:4/5/6 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor

942703 Engine uppercarr. charge air pressure sensor sensor defect low/short circuit to ground X703:4/5/6 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor

942802 Engine uppercarr. air filter sensor sensor defect high/short circ. to supply voltage X703:7/8/9 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor

942803 Engine uppercarr. air filter sensor sensor defect low/short circuit to ground X703:7/8/9 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor

943102 Engine uppercarr. charge air temperature sensor sensor defect high/short circ. to supply voltage X703:12/15 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor

070645 404
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

943103 Engine uppercarr. charge air temperature sensor sensor defect low/short circuit to ground X703:12/15 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor

943202 Engine uppercarr. coolant temperature sensor sensor defect high/short circ. to supply voltage X703:10/11 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor

943203 Engine uppercarr. coolant temperature sensor sensor defect low/short circuit to ground X703:10/11 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor

943313 Engine uppercarr. coolant level sensor open signal circuits X704:10/11 E 1
signal ignored, substitute value used
check cable/plugs for defects or breaks, replace sensor

943402 Engine uppercarr. oil temperature sensor sensor defect high/short circ. to supply voltage X703:16/17 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor

943403 Engine uppercarr. oil temperature sensor sensor defect low/short circuit to ground X703:16/17 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor

943601 Engine uppercarr. trigger flame type heater plug(s) FGK unit defect X701:4 E 1
shut off FGK and MVE

943614 Engine uppercarr. trigger flame type heater plug(s) FGK short circuit to supply voltage X701:4 E 1

943615 Engine uppercarr. trigger flame type heater plug(s) FGK open electric circuit X701:4 E 1
error report
check cable/plugs for breaks, replace Relaismodul

943618 Engine uppercarr. trigger flame type heater plug(s) FGK excess temperature X701:4 E 1
shut off FGK and MVE
check cable/plugs for short to ground, replace Relaismodul

070645 405
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

943714 Engine uppercarr. solenoid valve additional flow for starting short circuit to supply voltage X701:6 E 1

943715 Engine uppercarr. solenoid valve additional flow for starting open electric circuit X701:6 E 1
FSA data defective, FGK activation removed, MVE reset: automatic after error counter sequence, after regulator reset

943718 Engine uppercarr. solenoid valve additional flow for starting excess temperature X701:6 E 1
shut off FGK and MVE
check cable/plugs for short to ground, replace Relaismodul

943814 Engine uppercarr. engine start 50A short circuit to supply voltage X701:5 E 1

943815 Engine uppercarr. engine start 50A open electric circuit X701:5 E 1
starting procedure interrupted, shut down FGK and MVE
check cable/plugs for breaks, replace Relaismodul

943818 Engine uppercarr. engine start 50A excess temperature X701:5 E 1


starting procedure interrupted, shut down FGK and MVE
check cable/plugs for short to ground, replace Relaismodul

944118 Engine uppercarr. control device ECU excess temperature X701 E 1


error report
allow machine to cool, check installation location, if necessary take further cooling measures

944119 Engine uppercarr. control device ECU deviation X701 E 1


engine-Stop
regulator-reset (Kl.15), Check cable/plugs EDC-actuator, EDC-actuator; ECU, replace injector pump

944120 Engine uppercarr. control device ECU saving error X701 E 1

944221 Engine uppercarr. RAM/FLASH memory invalid data record X701 E 1


engine-Stop
insert new EEPROM with appropriate data record and carry out paging or replace LH-ECU1, regulator-reset (Kl.15)

070645 406
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

944320 Engine uppercarr. EEPROM memory saving error X701 E 1


use of redundant memory (Flash-EPROM)
insert new EEPROM and carry out paging or replace LH-ECU1, regulator-reset (Kl.15)

944321 Engine uppercarr. EEPROM memory invalid data record X701 E 1


engine start not possible
insert correct EEPROM with appropriate data record or replace LH-ECU1, regulator-reset (Kl.15)

946124 Engine uppercarr. charge air temperature pre-warning disruption limit 1 X703:12/15 E 1
warning, engine-protection-info, output reduction
reduce output, check air suction routing and engine

946125 Engine uppercarr. charge air temperature pre-warning disruption limit 2 X703:12/15 E 1
warning, engine-protection-info, output reduction
reduce output, if necessary shut off engine, check air suction routing and engine

946224 Engine uppercarr. coolant temperature pre-warning disruption limit 1 X703:10/11 E 1


warning, engine-protection-info, output reduction
reduce output, check coolant level and engine

946225 Engine uppercarr. coolant temperature pre-warning disruption limit 2 X703:10/11 E 1


warning, engine-protection-info, output reduction
reduce output, if necessary shut off engine, check coolant level and engine

946324 Engine uppercarr. coolant level pre-warning disruption limit 1 X704:11/12 E 1


warning
shut off engine, check coolant level and if necessary replenish, check for leaks

946424 Engine uppercarr. oil pressure pre-warning disruption limit 1 X703:1/2/3 E 1


warning
shut off engine, check oil level and if necessary replenish, check for leaks

946522 Engine uppercarr. air filter pressure pre-warning disruption limit 1 X703:7/8/9 E 1
pre-warning
replace air filter at next opportunity

946525 Engine uppercarr. air filter pressure pre-warning disruption limit 2 X703:7/8/9 E 1
warning
replace air filter immediately

070645 407
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

946624 Engine uppercarr. v-belt break pre-warning disruption limit 1 X703:14 E 1


warning
replace V-belts, check generator and replace if necessary

946724 Engine uppercarr. speed pre-warning disruption limit 1 X703:18/19/20/2 E 1


warning, engine-protection-info, injector quantities 0, activation of engine brake 1
shut off engine, regulator-reset (Kl.15)

946824 Engine uppercarr. charge air pressure pre-warning disruption limit 1 X703:4/5/6 E 1
signal ignored, substitute value will be used, error report
check air suction routing

946825 Engine uppercarr. charge air pressure pre-warning disruption limit 2 X703:4/5/6 E 1
signal ignored, substitute value will be used, error report
check air suction routing

946924 Engine uppercarr. oil temperature pre-warning disruption limit 1 X703:16/17 E 1


signal ignored, substitute value will be used, error report
check oil level/oil circulation

946925 Engine uppercarr. oil temperature pre-warning disruption limit 2 X703:16/17 E 1


signal ignored, substitute value will be used, error report
check oil level/oil circulation

948150 Engine uppercarr. v-belt-control service report interval 1 attained/exceeded X70 E 1


report
check and return

948250 Engine uppercarr. change engine oil filter service report interval 1 attained/exceeded X70 E 1
report
check and return

948350 Engine uppercarr. change engine oil service report interval 1 attained/exceeded X70 E 1
report
change oil and return

948351 Engine uppercarr. change engine oil service report interval 2 attained/exceeded X70 E 1
report
change oil and return

070645 408
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

948352 Engine uppercarr. change engine oil service report interval 3 attained/exceeded X70 E 1
report
change oil and return

948353 Engine uppercarr. change engine oil service report interval 4 attained/exceeded X70 E 1
report
change oil and return

948354 Engine uppercarr. change engine oil service report interval 5 attained/exceeded X70 E 1
report
change oil and return

948355 Engine uppercarr. change engine oil service report interval 6 attained/exceeded X70 E 1
report
change oil and return

948356 Engine uppercarr. change engine oil service report interval 7 attained/exceeded X70 E 1
report
change oil and return

948357 Engine uppercarr. change engine oil service report interval 8 attained/exceeded X70 E 1
report
change oil and return

948358 Engine uppercarr. change engine oil service report interval 9 attained/exceeded X70 E 1
report
change oil and return

948359 Engine uppercarr. change engine oil service report interval 10 attained/exceeded X70 E 1
report
change oil and return

948650 Engine uppercarr. check battery service report interval 1 attained/exceeded X70 E 1
report
check and return

948750 Engine uppercarr. change water filter service report interval 1 attained/exceeded X70 E 1
report
change filter and return

070645 409
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

948850 Engine uppercarr. check antifreeze service report interval 1 attained/exceeded X70 E 1
report
check and return

948950 Engine uppercarr. fuel filter level 1 service report interval 1 attained/exceeded X70 E 1
report
change filter and return

949150 Engine uppercarr. valve clearance service report interval 1 attained/exceeded X70 E 1
report
check and return

949250 Engine uppercarr. fuel injection valves service report interval 1 attained/exceeded X70 E 1
report
check and return

949350 Engine uppercarr. coolant service report interval 1 attained/exceeded X70 E 1


report
check and return

949450 Engine uppercarr. Exhaust gas recirculation (AGR) service report interval 1 attained/exceeded X70 E 1
report
change filter and return

971020 gear ASTRONIC: Main cut-off valve Y10 short circuit to ground E 1
Travel: Switching blocked - condition: Clutch opens, neutral switching blocked - automatic blocked
RESET - otherwise replace gear adjuster, ZF 10

971021 gear ASTRONIC: Main cut-off valve Y10 short circuit to supply voltage E 1
Switching blocked
RESET - otherwise replace gear adjuster, ZF 74

971022 gear ASTRONIC: Main cut-off valve Y10 interruption E 2


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 42

971120 gear ASTRONIC: Solenoid valve Y1 gear brake short circuit to ground E 1
Increased switch times - sporadic upshift locking - automatic blocked
RESET - otherwise replace gear adjuster, ZF 17

070645 410
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

971121 gear ASTRONIC: Solenoid valve Y1 gear brake short circuit to supply voltage E 1
Switching blocked
RESET - otherwise replace gear adjuster, ZF 81

971122 gear ASTRONIC: Solenoid valve Y1 gear brake interruption E 1


Increased switch times - sporadic upshift locking - automatic blocked
RESET - otherwise replace gear adjuster, ZF 49

971220 gear ASTRONIC: Solenoid valve Y2 splitter short circuit to ground E 2


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 2

971221 gear ASTRONIC: Solenoid valve Y2 splitter short circuit to supply voltage E 1
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 66

971222 gear ASTRONIC: Solenoid valve Y2 splitter interruption E 2


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 34

971320 gear ASTRONIC: Solenoid valve Y3 splitter short circuit to ground E 2


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 3

971321 gear ASTRONIC: Solenoid valve Y3 splitter short circuit to supply voltage E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 67

971322 gear ASTRONIC: Solenoid valve Y3 splitter interruption E 2


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 35

971420 gear ASTRONIC: Solenoid valve Y4 gap short circuit to ground E 2


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 04

971421 gear ASTRONIC: Solenoid valve Y4 gap short circuit to supply voltage E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 68

070645 411
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

971422 gear ASTRONIC: Solenoid valve Y4 gap interruption E 2


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 36

971520 gear ASTRONIC: Solenoid valve Y5 gap short circuit to ground E 2


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 05

971521 gear ASTRONIC: Solenoid valve Y5 gap short circuit to supply voltage E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 69

971522 gear ASTRONIC: Solenoid valve Y5 gap interruption E 2


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 37

971620 gear ASTRONIC: Solenoid valve Y6 switching short circuit to ground E 2


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 6

971621 gear ASTRONIC: Solenoid valve Y6 switching short circuit to supply voltage E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 70

971622 gear ASTRONIC: Solenoid valve Y6 switching interruption E 2


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 38

971720 gear ASTRONIC: Solenoid valve Y7 switching short circuit to ground E 2


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 7

971721 gear ASTRONIC: Solenoid valve Y7 switching short circuit to supply voltage E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 71

971722 gear ASTRONIC: Solenoid valve Y7 switching interruption E 2


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 39

070645 412
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

971820 gear ASTRONIC: Solenoid valve Y8 group short circuit to ground E 2


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 8

971821 gear ASTRONIC: Solenoid valve Y8 group short circuit to supply voltage E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 72

971822 gear ASTRONIC: Solenoid valve Y8 group interruption E 2


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 40

971920 gear ASTRONIC: Solenoid valve Y9 group short circuit to ground E 2


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 9

971921 gear ASTRONIC: Solenoid valve Y9 group short circuit to supply voltage E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 73

971922 gear ASTRONIC: Solenoid valve Y9 group interruption E 2


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 41

972033 gear ASTRONIC: Pressure reduction valve Mechanical error E 1


No function limitation
RESET - otherwise replace pressure limiting valve, ZF 125

972330 gear ASTRONIC: Splitter Switching error E 1


Only certain gears switchable - automatic blocked
RESET - otherwise replace gear adjuster, ZF 149

972331 gear ASTRONIC: Splitter Activation error E 1


System not avilable
RESET - otherwise replace gear adjuster, ZF 150

972332 gear ASTRONIC: Splitter Deactivation error E 1


Only certain gears switchable - automatic blocked
RESET - otherwise replace gear adjuster, ZF 148

070645 413
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

972430 gear ASTRONIC: Gap Switching error E 1


Only certain gears switchable, automatic neutral switching - automatic blocked
RESET - otherwise replace gear adjuster, ZF 152

972431 gear ASTRONIC: Gap Activation error E 1


Automatic neutral switching - automatic blocked
RESET - otherwise replace gear adjuster, ZF 153

972432 gear ASTRONIC: Gap Deactivation error E 1


Only certain gears switchable, automatic neutral switching - automatic blocked
RESET - otherwise replace gear adjuster, ZF 151

972530 gear ASTRONIC: Group Switching error E 1


Only certain gears switchable - automatic blocked
RESET - otherwise replace gear adjuster, ZF 146

972531 gear ASTRONIC: Group Activation error E 1


Only certain gears switchable - automatic blocked
RESET - otherwise replace gear adjuster, ZF 147

972532 gear ASTRONIC: Group Deactivation error E 1


Only certain gears switchable - automatic blocked
RESET - otherwise replace gear adjuster, ZF 145

972630 gear ASTRONIC: Main gear Switching error E 1


Automatic neutral switching. Gear engagement conditionally possible - automatic blocked
RESET - otherwise replace gear adjuster, ZF 156

972631 gear ASTRONIC: Main gear Activation error E 1


Automatic neutral switching. Gear engagement conditionally possible - automatic blocked
RESET - otherwise replace gear adjuster, ZF 155

972632 gear ASTRONIC: Main gear Deactivation error E 1


Travel: No gear switching possible: Only certain gears switchable - automatic blocked
RESET - otherwise replace gear adjuster, ZF 154

972742 gear ASTRONIC: Pressure sensor faulty/not present E 1


Output AL on display - no function limitation if air pressure high enough - automatic blocked
RESET - otherwise replace pressure sensor, ZF 126

070645 414
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

972842 gear ASTRONIC: Temperature sensor TCU faulty/not present E 1


No function limitation
RESET - otherwise replace gear adjuster, ZF 127

972942 gear ASTRONIC: Temperature sensor gear oil faulty/not present E 1


No function limitation
RESET - otherwise replace gear adjuster, ZF 128

973020 gear ASTRONIC: Sensor switching short circuit to ground E 1


Travel: Gear switching blocked - condition: Start-up gears can be switched
RESET - otherwise replace gear adjuster, ZF 130

973021 gear ASTRONIC: Sensor switching short circuit to supply voltage E 1


Travel: Gear switching blocked - condition: Start-up gears can be switched
RESET - otherwise replace gear adjuster, ZF 129

973022 gear ASTRONIC: Sensor switching interruption E 1


Travel: Gear switching blocked - condition: Start-up gears can be switched
RESET - otherwise replace gear adjuster, ZF 131

973025 gear ASTRONIC: Sensor switching Self-adjustment E 2


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 132

973042 gear ASTRONIC: Sensor switching faulty/not present E 1


Automatic neutral switching during travel; Automatic gear engagement during travel
RESET - otherwise replace gear adjuster, ZF 158

973120 gear ASTRONIC: Sensor gap short circuit to ground E 1


Only certain gears switchable - automatic blocked
RESET - otherwise replace gear adjuster, ZF 134

973121 gear ASTRONIC: Sensor gap short circuit to supply voltage E 1


Only certain gears switchable - automatic blocked
RESET - otherwise replace gear adjuster, ZF 133

973122 gear ASTRONIC: Sensor gap interruption E 1


Only certain gears switchable - automatic blocked
RESET - otherwise replace gear adjuster, ZF 135

070645 415
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

973125 gear ASTRONIC: Sensor gap Self-adjustment E 2


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 136

973220 gear ASTRONIC: Sensor group short circuit to ground E 1


Only certain gears switchable - automatic blocked
RESET - otherwise replace gear adjuster, ZF 138

973221 gear ASTRONIC: Sensor group short circuit to supply voltage E 1


Only certain gears switchable - automatic blocked
RESET - otherwise replace gear adjuster, ZF 137

973222 gear ASTRONIC: Sensor group interruption E 1


Only certain gears switchable - automatic blocked
RESET - otherwise replace gear adjuster, ZF 139

973225 gear ASTRONIC: Sensor group Self-adjustment E 2


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 140

973242 gear ASTRONIC: Sensor group faulty/not present E 1


Automatic neutral switching during travel; Automatic gear engagement during travel
RESET - otherwise replace gear adjuster, ZF 159

973320 gear ASTRONIC: Sensor splitter short circuit to ground E 1


Only every 2nd gear can be engaged, switch delay - automatic blocked
RESET - otherwise replace gear adjuster, ZF 142

973321 gear ASTRONIC: Sensor splitter short circuit to supply voltage E 1


Only every 2nd gear can be engaged, switch delay - automatic blocked
RESET - otherwise replace gear adjuster, ZF 141

973322 gear ASTRONIC: Sensor splitter interruption E 1


Only every 2nd gear can be engaged, switch delay - automatic blocked
RESET - otherwise replace gear adjuster, ZF 143

973325 gear ASTRONIC: Sensor splitter Self-adjustment E 2


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 144

070645 416
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

973342 gear ASTRONIC: Sensor splitter faulty/not present E 1


Automatic neutral switching during travel; Automatic gear engagement during travel
RESET - otherwise replace gear adjuster, ZF 160

973441 gear ASTRONIC: Sensor gear input speed Signal(s) implausible E 1


Travel: Switching blocked - cond.: Clutch opens, neut. switching blocked -system gear dep. conditionally available
RESET - check speed sensor 1 and 2, ZF 102

973442 gear ASTRONIC: Sensor gear input speed faulty/not present E 1


Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - otherwise replace gear adjuster, ZF 98

973520 gear ASTRONIC: Sensor gear input speed 1 short circuit to ground X45:6/11/18 E 1
Travel: Switching blocked - Automatic blocked
RESET- otherwise replace sensor, cable harness or gear adjuster, ZF 22

973521 gear ASTRONIC: Sensor gear input speed 1 short circuit to supply voltage X45:6/11/18 E 1
No function limitation - Automatic blocked
RESET- otherwise replace sensor, cable harness or gear adjuster, ZF 86

973522 gear ASTRONIC: Sensor gear input speed 1 interruption X45:6/11/18 E 1


Travel: Switching blocked - Automatic blocked
RESET- otherwise replace sensor, cable harness or gear adjuster, ZF 54

973542 gear ASTRONIC: Sensor gear input speed 1 faulty/not present X45:6/11/18 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - otherwise replace cable harness or speed sensor, ZF 99

973642 gear ASTRONIC: Gear output rpm 2,travel speed CAN faulty/not present E 1
No function limitation
RESET - check tacho system, ZF 100

973742 gear ASTRONIC: Sensor gear input speed 1/2 faulty/not present E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - check speed sensor 1 and 2, ZF 101

973831 gear ASTRONIC: TCU cut-off relay Activation error E 2


System not avilable
RESET - check Kl 30 ECU - otherwise replace gear adjuster, ZF 170

070645 417
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

973832 gear ASTRONIC: TCU cut-off relay Deactivation error E 2


System not avilable
RESET - otherwise replace gear adjuster, ZF 169

974020 gear ASTRONIC: Solenoid valve Y15 "Clutch closes slowly" short circuit to ground X45:7 E 1
Increased switch times - sporadic upshift locking - automatic blocked
RESET - otherwise replace gear adjuster, ZF 19

974021 gear ASTRONIC: Solenoid valve Y15 "Clutch closes slowly" short circuit to supply voltage X45:7 E 2
Switching blocked - clutch function limited - condition: Neutral switching - system not available
RESET - otherwise replace cable harness coupling adjuster or coupling adjuster, ZF 83

974022 gear ASTRONIC: Solenoid valve Y15 "Clutch closes slowly" interruption X45:7 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - otherwise replace cable harness coupling adjuster or coupling adjuster, ZF 51

974033 gear ASTRONIC: Solenoid valve Y15 "Clutch closes slowly" Mechanical error X45:7 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - otherwise replace coupling adjuster, ZF 122

974120 gear ASTRONIC: Solenoid valve Y14 "Clutch closes quickly" short circuit to ground X45:8 E 1
Increased switch times - sporadic upshift locking - automatic blocked
RESET - otherwise replace gear adjuster, ZF 21

974121 gear ASTRONIC: Solenoid valve Y14 "Clutch closes quickly" short circuit to supply voltage X45:8 E 2
Switching blocked - clutch function limited - condition: Neutral switching - system not available
RESET - otherwise replace cable harness coupling adjuster or coupling adjuster, ZF 85

974122 gear ASTRONIC: Solenoid valve Y14 "Clutch closes quickly" interruption X45:8 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - otherwise replace cable harness coupling adjuster or coupling adjuster, ZF 53

974133 gear ASTRONIC: Solenoid valve Y14 "Clutch closes quickly" Mechanical error X45:8 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - otherwise replace coupling adjuster, ZF 123

974220 gear ASTRONIC: Solenoid valve Y17 "Clutch opens slowly" short circuit to ground X45:9 E 1
Increased switch times - sporadic upshift locking - automatic blocked
RESET - otherwise replace gear adjuster, ZF 18

070645 418
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

974221 gear ASTRONIC: Solenoid valve Y17 "Clutch opens slowly" short circuit to supply voltage X45:9 E 2
Switching blocked - clutch function limited - condition: Neutral switching - system not available
RESET - otherwise replace cable harness coupling adjuster or coupling adjuster, ZF 82

974222 gear ASTRONIC: Solenoid valve Y17 "Clutch opens slowly" interruption X45:9 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - otherwise replace cable harness coupling adjuster or coupling adjuster, ZF 50

974233 gear ASTRONIC: Solenoid valve Y17 "Clutch opens slowly" Mechanical error X45:9 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - otherwise replace coupling adjuster, ZF 120

974320 gear ASTRONIC: Solenoid valve Y16 "Clutch opens quickly" short circuit to ground X45:12 E 1
Increased switch times - sporadic upshift locking - automatic blocked
RESET - otherwise replace gear adjuster, ZF 20

974321 gear ASTRONIC: Solenoid valve Y16 "Clutch opens quickly" short circuit to supply voltage X45:12 E 2
Switching blocked - clutch function limited - condition: Neutral switching - system not available
RESET - otherwise replace cable harness coupling adjuster or coupling adjuster, ZF 84

974322 gear ASTRONIC: Solenoid valve Y16 "Clutch opens quickly" interruption X45:12 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - otherwise replace cable harness coupling adjuster or coupling adjuster, ZF 52

974333 gear ASTRONIC: Solenoid valve Y16 "Clutch opens quickly" Mechanical error X45:12 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - otherwise replace coupling adjuster, ZF 121

974424 gear ASTRONIC: Sensor clutch voltage below required value X45:10/15 E 1
Travel: Reduced comfort when travelling, no ranging, automatic time-controlled neutral switching, automatically blocked
RESET - Replace gear adjuster or coupling adjuster, ZF 107

974425 gear ASTRONIC: Sensor clutch Self-adjustment X45:10/15 E 2


System not avilable
RESET - otherwise replace gear adjuster, coupling adjuster, coupling, ZF 117

974442 gear ASTRONIC: Sensor clutch faulty/not present X45:10/15 E 1


Travel: Reduced comfort when travelling, no ranging, automatic time-controlled neutral switching, automatically blocked
RESET - otherwise replace coupling adjuster, ZF 124

070645 419
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

974525 gear ASTRONIC: Clutch Self-adjustment E 2


System not avilable
RESET - otherwise replace gear adjuster, coupling adjuster, coupling, ZF 117

974531 gear ASTRONIC: Clutch Activation error E 2


Travel: Gear switching blocked - cond.: Engine stalled - automatic neutral switching - system not available
RESET - otherwise replace gear adjuster, coupling adjuster, coupling, ZF 118

974532 gear ASTRONIC: Clutch Deactivation error E 2


Switching blocked - clutch function limited - condition: Neutral switching - system not available
RESET - otherwise replace gear adjuster, coupling adjuster, coupling, ZF 119

974533 gear ASTRONIC: Clutch Mechanical error E 1


Standstill: forced neutral switching, if N reached, no further system limitation
Switch off ignition, coupling opens, gear in N, ZF 114

975421 gear ASTRONIC: TCU power supply short circuit to supply voltage X44:1/4/5 E 1
No function limitation
RESET - otherwise replace sensor or cables or gear adjuster, ZF 86

975422 gear ASTRONIC: TCU power supply interruption X44:1/4/5 E 1


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace sensor or cables or gear adjuster, ZF 54

975923 gear ASTRONIC: On-board supply excess voltage E 1


No function limitation
RESET - check on-board circuit voltage, ZF 104

975924 gear ASTRONIC: On-board supply voltage below required value E 2


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - check on-board circuit voltage, ZF 105

976031 gear ASTRONIC: Ignition ON Kl.15 Activation error E 1


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - check CAN-communication ECU - MOT, ZF 175

976241 gear ASTRONIC: Idle switch Signal(s) implausible E 1


Condition: No ranging and start-up possible - automatic blocked
RESET - check CAN-communication ECU - MOT (accelerator pedal), ZF 166

070645 420
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

976401 gear ASTRONIC: CAN-interface system Permanent error, Bus communication interrupted X44:8/12 E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - check cables of CAN communication, ZF 177

976404 gear ASTRONIC: CAN-interface system Memory error (queue overrun) X44:8/12 E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - check cables of CAN communication, ZF 179

976501 gear ASTRONIC: CAN-interface ZF Permanent error, Bus communication interrupted X44:8/12 E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - check cables of CAN communication, ZF 188

976503 gear ASTRONIC: CAN-interface ZF Faulty/missing, max. cycle time exceeded X44:8/12 E 1
Travel: Switching blocked - condition: automat. Engagement of last start-up gear - reverse gear blocked
RESET - otherwise replace gear adjuster, ZF 110

976610 gear ASTRONIC: Internal error TCU Incorrect interrupt triggered 4 E 2


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - load software again - otherwise replace gear adjuster, ZF 188

976611 gear ASTRONIC: Internal error TCU Memory error (stack watch) 4 E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - load software again - otherwise replace gear adjuster, ZF 189

976612 gear ASTRONIC: Internal error TCU Parameter faulty 4 E 2


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - load EOL parameter again, ZF 190

976613 gear ASTRONIC: Internal error TCU EEPROM parameter check sum 4 E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - Enter EOL parameter check sum again, ZF 191

976614 gear ASTRONIC: Internal error TCU EEPROM access faulty 4 E 1


Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - otherwise replace gear adjuster, ZF 192

976640 gear ASTRONIC: Internal error TCU Communication faulty/not present 4 E 2


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - otherwise replace gear adjuster, ZF 90

070645 421
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

976644 gear ASTRONIC: Internal error TCU excess temperature 4 E 2


Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - Check cooling system gear again - otherwise replace gear adjuster, ZF 193

976703 gear ASTRONIC: CAN-data transfer ABS/ASR (ID 512) Faulty/missing, max. cycle time exceeded X44:8/12 E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - check CAN-communication ECU - ABS, ZF 216

976803 gear ASTRONIC: CAN-data transfer ABS/ASR (ID 513) Faulty/missing, max. cycle time exceeded X44:8/12 E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - check CAN-communication ECU - ABS, ZF 217

976903 gear ASTRONIC: CAN-data transfer E/A-module (ID 588) Faulty/missing, max. cycle time exceeded X44:8/12 E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - check CAN-communication ECU - EA-module, ZF 230

977003 gear ASTRONIC: CAN-data transfer engine (ID 592) Faulty/missing, max. cycle time exceeded X44:8/12 E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - check CAN-communication ECU - MOT, ZF 218

977103 gear ASTRONIC: CAN-data transfer engine (ID 593) Faulty/missing, max. cycle time exceeded X44:8/12 E 2
Travel: Switching blocked - condition: Clutch opens, neutral switching - system not available
RESET - check CAN-communication ECU - MOT, ZF 219

977203 gear ASTRONIC: CAN-data transfer retarder (ID 772) Faulty/missing, max. cycle time exceeded X44:8/12 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - check CAN-communication ECU - INT, ZF 220

977603 gear ASTRONIC: CAN-data transfer Intarder (12xx) Faulty/missing, max. cycle time exceeded X44:8/12 E 1
Loss of comfort during start-up, switching and ranging
RESET - check CAN-communication ECU - INT, ZF 225

977703 gear ASTRONIC: CAN-data transfer engine (ID 1360) Faulty/missing, max. cycle time exceeded X44:8/12 E 2
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - check CAN-communication ECU - MOT, ZF 223

978042 gear ASTRONIC: CAN-signal travel speed faulty/not present X44:8/12 E 1


No start-up gear calculation - no travel resistance calculation - travel strategy only operates conditionally
RESET - check CAN signals ECU/ABS/ASR, ZF 92/93/94

070645 422
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

978142 gear ASTRONIC: CAN-signal average speed front axle faulty/not present X44:8/12 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - check CAN-communication ECU - ABS, ZF 197

978242 gear ASTRONIC: CAN-signal differential speed front axle faulty/not present X44:8/12 E 1
No function limitation
RESET - check CAN-communication ECU - ABS, ZF 198

978342 gear ASTRONIC: CAN-signal intarder actual moment faulty/not present X44:8/12 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - check CAN-communication ECU - INT, ZF 28

978442 gear ASTRONIC: CAN-signal intarder shift-in faulty/not present X44:8/12 E 1


No shift-in requirements with retarder operation - loss of cooling output
RESET - check CAN-communication ECU - INT, ZF 29

978502 gear ASTRONIC: CAN-signal Telma actual moment Signal on CAN faulty/not present X44:8/12 E 1
No function limitation
RESET - check CAN-communication ECU - EA-module, ZF 229

978642 gear ASTRONIC: CAN-signal WSK-retarder faulty/not present E 1


Limited calculation of road resistance, error calculations with automatic gear selection thus possible
Signals available on CAN again or switch on/off ignition, ZF 24

979042 gear ASTRONIC: CAN-signal engine speed faulty/not present X44:8/12 E 1


Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - check CAN-communication ECU - MOT, ZF 97

979140 gear ASTRONIC: CAN-signal drive moment Soll Communication faulty/not present X44:8/12 E 1
Travel: Gear switching blocked - condition: Start-up gears can be switched - automatic blocked
RESET - check CAN-communication ECU - MOT, ZF 163

979242 gear ASTRONIC: CAN-signal drive moment Ist faulty/not present X44:8/12 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - check CAN-communication ECU - MOT, ZF 171

979342 gear ASTRONIC: CAN-signal engine moment dynamic faulty/not present X44:8/12 E 1
No function limitation
RESET - check CAN-communication ECU - MOT, ZF 167

070645 423
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

979442 gear ASTRONIC: CAN-signal engine break moment faulty/not present X44:8/12 E 1
Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - check CAN-communication ECU - MOT, ZF 31

979542 gear ASTRONIC: CAN-signal travel pedal faulty/not present X44:8/12 E 1


Loss of comfort during start-up, switching and ranging - automatic blocked
RESET - check CAN-communication ECU - MOT (accelerator pedal), ZF 165

979642 gear ASTRONIC: CAN-signal idle switch faulty/not present X44:8/12 E 1


No function limitation
RESET - check CAN-communication ECU - MOT (accelerator pedal), ZF 168

979742 gear ASTRONIC: CAN-signal brake switch faulty/not present X44:8/12 E 1


Comfort impeded when braking - automatic blocked
RESET - check CAN-communication ECU - MOT (brake switch), ZF 173

979942 gear ASTRONIC: CAN-signal Tempomat faulty/not present X44:8/12 E 1


Switch oscillation in Tempomat operation possible
RESET - check CAN-communication ECU - MOT (Temposet), ZF 96

981111 WSK: Outlet recirculation valve short circuit to ground E 1


WSK-ECU no longer controls the outlet (recirculation valve), retarder response time increases
Check cables, recirculation valve (inner res. approx. 120 Ohm; measure the WSK-ECU at the plug); replace WSK-ECU, ZF 01

981112 WSK: Outlet recirculation valve short circuit to supply voltage E 1


WSK-ECU no longer controls the outlet (recirculation valve), retarder response time increases
Check cables, recirculation valve (inner res. approx. 120 Ohm; measure the WSK-ECU at the plug); replace WSK-ECU, ZF 02

981113 WSK: Outlet recirculation valve Disconnection/wire break E 1


WSK-ECU no longer controls the outlet (recirculation valve), retarder response time increases
Check cables, recirculation valve (inner res. approx. 120 Ohm; measure the WSK-ECU at the plug); replace WSK-ECU, ZF 03

981211 WSK: Outlet WK-valve short circuit to ground E 1


WSK-ECU no longer controls the outlet (WK-valve), only converter operation possible
Check cables, WK-valve (inner resistance approx. 120 Ohm; measure the WSK-ECU at the plug); replace WSK-ECU, ZF 04

981212 WSK: Outlet WK-valve short circuit to supply voltage E 1


WSK-ECU no longer controls the outlet (WK-valve), no converter operation possible: line permanently active
Check cables, WK-valve (inner resistance approx. 120 Ohm; measure the WSK-ECU at the plug); replace WSK-ECU, ZF 05

070645 424
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

981213 WSK: Outlet WK-valve Disconnection/wire break E 1


WSK-ECU no longer controls the outlet (WK-valve), only converter operation possible
Check cables, WK-valve (inner resistance approx. 120 Ohm; measure the WSK-ECU at the plug); replace WSK-ECU, ZF 06

981911 WSK: Outlet proportional valve retarder short circuit to ground E 1


WSK-ECU no longer controls the prop.-valve; no more retarder torque available
Check cables, prop.-valve; replace WSK-ECU, ZF 10

981912 WSK: Outlet proportional valve retarder short circuit to supply voltage E 1
WSK-ECU no longer controls the prop.-valve; (line permanently active; if no earth shut-down path - permanent brake)
Check cables, prop.-valve; replace WSK-ECU, ZF 11

981913 WSK: Outlet proportional valve retarder Disconnection/wire break E 1


WSK-ECU no longer controls the prop.-valve; no more retarder torque available
Check cables, prop.-valve; replace WSK-ECU, ZF 12

981914 WSK: Outlet proportional valve retarder Error in component/element/transmission E 1


WSK-ECU no longer controls the prop.-valve; no more retarder torque available
Check cables, prop.-valve; replace WSK-ECU, ZF 13

982111 WSK: Outlet earth switching proportional valve retarder short circuit to ground E 1
WSK-ECU shuts down the retarder; retarder no longer available. (line permanently active)
Check cables, prop.-valve; replace WSK-ECU, ZF 14

982112 WSK: Outlet earth switching proportional valve retarder short circuit to supply voltage E 1
WSK-ECU shuts down the retarder; retarder no longer available
Check cables, prop.-valve; replace WSK-ECU, ZF 15

982211 WSK: Outlet earth switching WK-valve short circuit to ground E 1


WSK-ECU no longer controls outlet (WK-valve), only converter operation possible (depending on status output WK-valve)
Check cables, WK-valve (inner resistance approx. 120 Ohm; measure the WSK-ECU at the plug); replace WSK-ECU, ZF 16

982212 WSK: Outlet earth switching WK-valve short circuit to supply voltage E 1
WSK-ECU no longer controls outlet (WK-valve), only converter operation possible (depending on status output WK-valve)
Check cables, WK-valve (inner resistance approx. 120 Ohm; measure the WSK-ECU at the plug); replace WSK-ECU, ZF 17

982213 WSK: Outlet earth switching WK-valve Disconnection/wire break E 1


WSK-ECU no longer controls the outlet (WK-valve), only converter operation possible
Check cables, WK-valve (inner resistance approx. 120 Ohm; measure the WSK-ECU at the plug); replace WSK-ECU, ZF 18

070645 425
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

982316 WSK: Current sensing proportional valve retarder Permissible signal range fallen short of E 1
WSK-ECU shuts down the retarder; retarder no longer available
Replace WSK-ECU, ZF 24

982317 WSK: Current sensing proportional valve retarder Permissible signal range exceeded E 1
WSK-ECU shuts down the retarder; retarder no longer available
Replace WSK-ECU, ZF 25

983119 WSK: Turbine speed Signal faulty/lacking E 1


Turbine speed interrupted: Limitation retarder power to 250mA; opened WK does not close; no active diagnosis
Check CAN-Bus system, Bus subscriber, ZF 19

983211 WSK: Oil temperature sensor short circuit to ground E 1


WSK-ECU limits the maximum permissible braking action to 100kW
Check cables, temperature sensor; replace WSK-ECU, ZF 23

983213 WSK: Oil temperature sensor Disconnection/wire break E 1


WSK-ECU limits the maximum permissible braking action to 100kW
Check cables, temperature sensor; replace WSK-ECU, ZF 22

983217 WSK: Oil temperature sensor Permissible signal range exceeded E 1


Warning information
End converter operation; end or reduce retarder operation, ZF 20

983419 WSK: Engine speed Signal faulty/lacking E 1


Engine speed interrupted: WK only closes at KD-threshold; no active diagnosis
Check CAN-Bus system, Bus subscriber, ZF 34

984319 WSK: CAN-transmission error Signal faulty/lacking E 1


No direct error reaction
Check CAN-Bus system, Bus subscriber, ZF 37

984415 WSK: CAN-bus system Error in component/element/transmission E 1


No direct error reaction
Check CAN-Bus system, Bus subscriber, ZF 38

984615 WSK: CAN-Bus transmission Error in component/element/transmission E 1


No direct error reaction
Check CAN-Bus system, Bus subscriber, ZF 40

070645 426
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

985919 WSK: CAN-communication with engine (FMR1) Signal faulty/lacking E 1


Error reaction is dependent on the signals read in the message
Check CAN-Bus system, Bus subscriber, ZF 48

986119 WSK: CAN-communication with gear (EPS) Signal faulty/lacking E 1


Error reaction is dependent on the signals read in the message
Check CAN-Bus system, Bus subscriber, ZF 50

986219 WSK: CAN-communication with engine (FMR2) Signal faulty/lacking E 1


Error reaction is dependent on the signals read in the message
Check CAN-Bus system, Bus subscriber, ZF 49

986519 WSK: CAN-communication with gear (MKR) Signal faulty/lacking E 1


Error reaction is dependent on the signals read in the message
Check CAN-Bus system, Bus subscriber, ZF 47

987113 WSK: Terminal 30 Disconnection/wire break E 1


In operation: no reaction; with ignition OFF:no after-run operation
Check supply of WSK-ECU (cables), check fuse terminal 30, ZF 26

987216 WSK: Terminal 15 Permissible signal range fallen short of E 1


WSK-ECU shuts down the retarder; no retarder availability; digital outlets switched off; WK will not be closed
Check on-board supply voltage (battery, alternator), ZF 28

987217 WSK: Terminal 15 Permissible signal range exceeded E 1


WSK-ECU shuts down retarder; retarder no longer available
Check on-board supply voltage (battery, alternator), ZF 27

988218 WSK: Operating hours counter Plausibility error E 0


Operating hour meter can not be read from EEProm, WSK-ECU resets operating hour meter to 0
Switch ignition on and off, if error is active again replace WSK-ECU, ZF 31

988318 WSK: Error memory Plausibility error E 0


Error memory can not be read from EEProm, WSK-ECU rejects the "old" error memory content
Delete error memory, then switch ignition on and off, if error is active again replace WSK-ECU, ZF 32

988415 WSK: System error Error in component/element/transmission E 1

Replace WSK-ECU, ZF 35

070645 427