Column Reinforcement Details 2

The document contains specifications for reinforcing bars in concrete structures. It lists the bar size and spacing for main links and others in different zones. The concrete cover is 40mm and confining zone thickness is 450mm. Reinforcing includes #10 and #16 bars spaced at 75mm, 150mm and 175mm. Minimum bar lengths are also specified.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
95 views1 page

Column Reinforcement Details 2

The document contains specifications for reinforcing bars in concrete structures. It lists the bar size and spacing for main links and others in different zones. The concrete cover is 40mm and confining zone thickness is 450mm. Reinforcing includes #10 and #16 bars spaced at 75mm, 150mm and 175mm. Minimum bar lengths are also specified.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

C21 : Fy415 , COVER = 40MM C21 : Fy415 , COVER = 40MM C21 : Fy415 , COVER = 40MM C21 : Fy415 , COVER

Fy415 , COVER = 40MM C21 : Fy415 , COVER = 40MM

.
CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM

6M

Lo
Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS
TO
#10 @ 75 #10 @ 75 #10 @ 150 #10 @ 75 #10 @ 75 #10 @ 175 #10 @ 75 #10 @ 75 #10 @ 175 #10 @ 75 #10 @ 75 #10 @ 175

Lj
8.8M

.
350

350

350
300

Lo
#16 #16 #16 #16
450 450 450 450

8-#16 10-#16 10-#16 10-#16


C21 : Fy415 , COVER = 40MM C21 : Fy415 , COVER = 40MM C21 : Fy415 , COVER = 40MM C21 : Fy415 , COVER = 40MM C21 : Fy415 , COVER = 40MM C21 : Fy415 , COVER = 40MM
CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM CONFINING ZONE = 450 MM

MIN.
600
3.2M

Lv

H
MIN.
sw
Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS
TO
#10 @ 75 #10 @ 75 #10 @ 150 #10 @ 75 #10 @ 75 #10 @ 175 #10 @ 75 #10 @ 75 #10 @ 175 #10 @ 75 #10 @ 75 #10 @ 175 #10 @ 75 #10 @ 75 #10 @ 150 #10 @ 75 #10 @ 75 #10 @ 175
.

Lo
6M

.
350

350

350

350
300

300
#16 #16 #16 #16 #16 #16
450 450 450 450 450 450

8-#16 10-#16 10-#16 10-#16 8-#16 10-#16


C21 : Fy415 , COVER = 40MM C21 : Fy415 , COVER = 40MM C21 : Fy415 , COVER = 40MM C21 : Fy415 , COVER = 40MM C21 : Fy415 , COVER = 40MM C21 : Fy415 , COVER = 40MM
CONFINING ZONE = 485 MM CONFINING ZONE = 485 MM CONFINING ZONE = 485 MM CONFINING ZONE = 485 MM CONFINING ZONE = 485 MM CONFINING ZONE = 485 MM

0M

Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS
TO
#10 @ 75 #10 @ 75 #10 @ 150 #10 @ 75 #10 @ 75 #10 @ 175 #10 @ 75 #10 @ 75 #10 @ 175 #10 @ 75 #10 @ 75 #10 @ 175 #10 @ 75 #10 @ 75 #10 @ 150 #10 @ 75 #10 @ 75 #10 @ 175

3.2M 2 COLUMN REINFORCEMENT DETAILS


350

350

350

350
S-5
300

300
#16 #16 #16 #16 #16 #16
450 450 450 450 450 450

8-#16 10-#16 10-#16 10-#16 8-#16 10-#16


C21 : Fy415 , COVER = 40MM C21 : Fy415 , COVER = 40MM C21 : Fy415 , COVER = 40MM C21 : Fy415 , COVER = 40MM C21 : Fy415 , COVER = 40MM C21 : Fy415 , COVER = 40MM
CONFINING ZONE = FULL HEIGHT CONFINING ZONE = FULL HEIGHT CONFINING ZONE = FULL HEIGHT CONFINING ZONE = FULL HEIGHT CONFINING ZONE = FULL HEIGHT CONFINING ZONE = FULL HEIGHT

-1.2M

Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS
TO SECTION AT "A"
#10 @ 75 #10 @ 75 --- #10 @ 75 #10 @ 75 --- #10 @ 75 #10 @ 75 --- #10 @ 75 #10 @ 75 --- #10 @ 75 #10 @ 75 --- #10 @ 75 #10 @ 75 ---

0M
350

350

350

350
300

300
#16 #16 #16 #16 #16 #16
450 450 450 450 450 450

8-#16 10-#16 10-#16 10-#16 8-#16 10-#16

COLUMN MARKED C1 C2 C3 C4 C5 C6

COLUMN AND WALL SCHEDULE


(SCALE 1:25)
NOTES:
1. BE = BOUNDARY ELEMENT AS PER ACI 318M - 2014. PROVIDE CONFINING REINFORCEMENT ACROSS ENTIRE HEIGHT OF WALL IN THE BOUNDARY ELEMENT
2. Z1 = SPECIAL CONFINING ZONE AS PER ACI 318M - 2014, Z2 = REMAINING ZONES AS PER ACI 318M - 2014

1 COLUMN SCHEDULE
S-5

PROJECT TITLE & LOCATION OWNER Republic Act. R.A. 9266 and Section 33 of the IRR REVISION SHEET CONTENT SHEET NO.
Drawings and specification and other contract
Paul Christian L. Domingo PROPOSED EXTENSION & RENOVATION
documents duly signed, stamped or sealed, as
instruments of service, are the intellectual property
COLUMN SCHEDULE

S5
CIVIL ENGINEER MR. OLAN KRISTOPHER SUPNET and documents of Architect whether the object for COLUMN REINFORCEMENT
OF TWO-STOREY RESIDENTIAL BUILDING & MRS. HEIDI SUPNET which they are made is executed or not. It shall be
unlawful for any person to duplicated or to make DETAIL
P.R.C. No.: 0190605 P.T.R. No.: 9493262
copies of said documents for use in the repetition of RAFTER CONNECTION DETAIL
T.I.N. No.: 713-896-254 Date: June 25, 2023 and for other projects or buildings, whether executed
partly or in whole, without the written consent of PURLINS CONNECTION DETAIL
Place: - architect or author of said documents.

You might also like