0% found this document useful (0 votes)
1K views2 pages

SSAS TEST Instruction

The document provides instructions for testing an SSAS (Ship Security Alert System) device. It describes entering SSAS manager mode by pressing specific buttons and entering passwords. It then outlines two methods for testing the SSAS button by pressing it and verifying test messages appear, as well as how to quit SSAS manager mode or cancel a test transmission.

Uploaded by

vodoley634
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as ODT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views2 pages

SSAS TEST Instruction

The document provides instructions for testing an SSAS (Ship Security Alert System) device. It describes entering SSAS manager mode by pressing specific buttons and entering passwords. It then outlines two methods for testing the SSAS button by pressing it and verifying test messages appear, as well as how to quit SSAS manager mode or cancel a test transmission.

Uploaded by

vodoley634
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as ODT, PDF, TXT or read online on Scribd
You are on page 1/ 2

SSAS TEST (FELCOM18 IC-307)

To conduct the test the equipment must be in the SSAS manager mode.
To access SSAS manager mode:
1. Press “F8” to show System Setup menu
2. Choose Command Window
3. Press “Enter”
4. On the Enter JOB type: ssas manager
5. Press “Enter”
6. Type password: ship security alert
7. Press “Enter”. Indication “SSAS Manager Mode” is flashing at the top of the
screen
8. Press “Esc” several times to close menu
Testing the Button:
1. Press “F7” to display the Options menu
2. Choose Test window
3. Choose Distress/SSAS Button Test
4. Press “Enter” to start the test. The display shows message in red:
“Distress/SSAS buttons are under test”
5. Open the button cover on the No.1 SSAS (IC-307)
6. Push the button in. Message “SSAS UNIT works correctly” appears
7. 30 sec after the button is pushed in – the SSAS test report is automatically sent
8. Turn off the button of the No.1 SSAS (IC-307)
9. Close the button cover
10. To escape from test press “Esc” twice. Test mode is stopped. Message
“Distress/SSAS Buttons returned to NORMAL OPERATION” appears
11. Press “Esc” three times to return to standby display
12. When the SSAS test report is sent: “Successful Sending message” and
“ Delivery Confirmed: A specified email address”
13. Press “Esc” to continue
14. Confirm that SSAS test report is sent to the stations

Quitting SSAS manager mode:


- On the Enter JOB in Command Window type: “quit” or “quit ssas”

To cancel the transmission:


1. Within 30 sec after the button is pressed – press the button on the SSAS again
to turn it off
2. More than 30 sec after the button is pressed:

Method 1:
- Turn off the button of all SSAS IC-307
- Press the button ON -> OFF -> ON -> OFF on one of the SSAS IC-307

Method 2:
- Switch to the SSAS manager mode
- Press “F8” to show System Setup menu
- Choose Command Window and press “Enter”
- On the Enter JOB type: terminate ssas alert
- Press “Enter”